createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721807243100
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd1052000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose26-08-2024 16:00:00
tenderQueryClose14-08-2024 16:00:00
technicalBidOpen27-08-2024 16:01:00
publishedDate24-07-2024 13:35:18
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate19-08-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonGnanesh Kumar V P
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9686183379
tenderSupplierListNone
tenderSchedule
createdTs1721807243128
version4
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT537
titleConstruction of primary health centre at kallahalli in hospet taluk in vijayanagar district and Construction of primary health centre at chilakanahatti in hospet taluk in vijayanagar district.
descriptionConstruction of primary health centre at kallahalli in hospet taluk in vijayanagar district and Construction of primary health centre at chilakanahatti in hospet taluk in vijayanagar district.
categoryWORKS
categoryTextWorks
ecv70107335.12
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount80000000.0
groupOverheadTotal0.0
fileNumberAEE/BALLARI/KKRDB/719
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17218072430000NoneNoneBuildingsConstruction of primary health centre at kallahalli in hospet taluk in vijayanagar district35053667.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3596759130996NonePWD SR 2023-24 V- III Page No-9 It No-2.5Aupto plinth Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.9215.91FalseNoneNoneFalseNoneFalse7746.89720
3596760130996NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth.Cum117.7117.7477.3FalseNoneNoneFalseNoneFalse56178.210
3596761130996NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m.Cum126.37126.37454.299FalseNoneNoneFalseNoneFalse57409.764630
3596762130996NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.75190.024FalseNoneNoneFalseNoneFalse85463.2940
3596763130996NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.412.886FalseNoneNoneFalseNoneFalse8844.95040
3596764130996NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.Cum7017.697017.69126.605FalseNoneNoneFalseNoneFalse888474.642450
3596765130996NonePWD SR 2023-24 V-1I Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2891.0FalseNoneNoneFalseNoneFalse130264.20
3596766130996NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57454.299FalseNoneNoneFalseNoneFalse149723.321430
3596767130996NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum536.48536.48281.749FalseNoneNoneFalseNoneFalse151152.703520
3596768130996NonePWD SR 2023-24 V-I Page No-15 It No-2.2.3Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7850.37850.376.112FalseNoneNoneFalseNoneFalse597502.03360
3596769130996NonePWD SR 2023-24 V-I Page No-16 It No-2.4.3Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates,Cum7850.37850.319.152FalseNoneNoneFalseNoneFalse150348.94560
3596770130996NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7239.53FalseNoneNoneFalseNoneFalse317375.30160
3596771130996NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7220.7FalseNoneNoneFalseNoneFalse166194.5040
3596772130996NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.2213.44FalseNoneNoneFalseNoneFalse1489652.23680
3596773130996NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0276.112FalseNoneNoneFalseNoneFalse47799.858240
3596774130996NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%)Cum350.88350.88126.605FalseNoneNoneFalseNoneFalse44423.16240
3596775130996NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% )Cum5495.215495.2120.08FalseNoneNoneFalseNoneFalse110343.81680
3596776130996NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%)Cum4014.364014.3639.53FalseNoneNoneFalseNoneFalse158687.65080
3596777130996NonePWD SR 2023-24 V-1 Page No-112 It No-11Foundation upto PlinthForm Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% )Cum802.87802.8720.7FalseNoneNoneFalseNoneFalse16619.4090
3596778130996NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2above plinth Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR .Cum8478.478478.475.5FalseNoneNoneFalseNoneFalse46631.5850
3596779130996NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOORCum8563.268563.260.132FalseNoneNoneFalseNoneFalse1130.350320
3596780130996NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill -GROUND FLOORCum8478.478478.470.715FalseNoneNoneFalseNoneFalse6062.106050
3596781130996NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOORCum8563.268563.260.022FalseNoneNoneFalseNoneFalse188.391720
3596782130996NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOORCum8478.478478.473.395FalseNoneNoneFalseNoneFalse28784.405650
3596783130996NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOORCum8478.478478.4784.53FalseNoneNoneFalseNoneFalse716685.06910
3596784130996NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOORCum8563.268563.262.7FalseNoneNoneFalseNoneFalse23120.8020
3596785130996NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOORCum8478.478478.4742.11FalseNoneNoneFalseNoneFalse357028.37170
3596786130996NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOORCum8563.268563.261.66FalseNoneNoneFalseNoneFalse14215.01160
3596787130996NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C ColumnCum8478.478478.4725.17FalseNoneNoneFalseNoneFalse213403.08990
3596788130996NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C ColumnCum8563.268563.268.86FalseNoneNoneFalseNoneFalse75870.48360
3596789130996NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty GROUND FLOORCum5934.935934.9325.17FalseNoneNoneFalseNoneFalse149382.18810
3596790130996NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty TERRACE FLOORCum5994.285994.288.86FalseNoneNoneFalseNoneFalse53109.32080
3596791130996NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM GROUND FLOORCum5087.085087.0842.11FalseNoneNoneFalseNoneFalse214216.93880
3596792130996NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM TERRACE FLOORCum5137.955137.951.66FalseNoneNoneFalseNoneFalse8528.9970
3596793130996NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL GROUND FLOORCum5087.085087.085.5FalseNoneNoneFalseNoneFalse27978.940
3596794130996NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL TERRACE FLOORCum5137.955137.950.132FalseNoneNoneFalseNoneFalse678.20940
3596795130996NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof Slab GROUND FLOORCum4239.234239.2384.53FalseNoneNoneFalseNoneFalse358342.11190
3596796130996NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof SlabTERRACE FLOORCum4281.634281.632.7FalseNoneNoneFalseNoneFalse11560.4010
3596797130996NonePWD SR 2023-24 V-1 Page No-112 It No-16Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Staircase and other similar structures (50%) Staircase GROUND FLOORCum4239.234239.233.395FalseNoneNoneFalseNoneFalse14392.185850
3596798130996NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOORCum3815.313815.310.715FalseNoneNoneFalseNoneFalse2727.946650
3596799130996NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOORCum3853.463853.460.022FalseNoneNoneFalseNoneFalse84.776120
3596800130996NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOORt110837.22110837.2221.12FalseNoneNoneFalseNoneFalse2340882.08640
3596801130996NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) TERRACE FLOORt111945.59111945.592.3FalseNoneNoneFalseNoneFalse257474.8570
3596802130996NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORCum9873.599873.59247.82FalseNoneNoneFalseNoneFalse2446873.07380
3596803130996NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. TERRACE FLOORCum9972.329972.3246.69FalseNoneNoneFalseNoneFalse465607.62080
3596804130996NonePWD SR 2023-24 V11 Page No-17 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORSqm1313.341313.34118.68FalseNoneNoneFalseNoneFalse155867.19120
3596805130996NonePWD SR 2023-24 V11 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.168FalseNoneNoneFalseNoneFalse20568.539040
3596806130996NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOORSqm6145.446145.448.64FalseNoneNoneFalseNoneFalse53096.60160
3596807130996NonePWD SR 2023-24 V11 Page No-104 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOREach1258.821258.8212.0FalseNoneNoneFalseNoneFalse15105.840
3596808130996NonePWD SR 2023-24 V11 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOREach148.68148.684.0FalseNoneNoneFalseNoneFalse594.720
3596809130996NonePWD SR 2023-24 V11 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOREach1380.241380.244.0FalseNoneNoneFalseNoneFalse5520.960
3596810130996NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOREach1303.421303.422.0FalseNoneNoneFalseNoneFalse2606.840
3596811130996NonePWD SR 2023-24 V11 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOREach293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3596812130996NonePWD SR 2023-24 V11 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOREach161.07161.078.0FalseNoneNoneFalseNoneFalse1288.560
3596813130996NonePWD SR 2023-24 V11 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOREach68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3596814130996NonePWD SR 2023-24 V11 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOREach340.72340.7216.0FalseNoneNoneFalseNoneFalse5451.520
3596815130996NonePWD SR 2023-24 V11 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOREach358.07358.072.0FalseNoneNoneFalseNoneFalse716.140
3596816130996NonePWD SR 2023-24 V11 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOREach74.3474.348.0FalseNoneNoneFalseNoneFalse594.720
3596817130996NonePWD SR 2023-24 V11 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOORm64.4264.4216.8FalseNoneNoneFalseNoneFalse1082.2560
3596818130996NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm8343.428343.4248.6FalseNoneNoneFalseNoneFalse405490.2120
3596819130996NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3596820130996NonePWD SR 2023-24 V11 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7085.847085.842.88FalseNoneNoneFalseNoneFalse20407.21920
3596821130996NonePWD SR 2023-24 V11 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOORSqm394.0394.020.475FalseNoneNoneFalseNoneFalse8067.150
3596822130996NonePWD SR 2023-24 V11 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOORSqm2931.472931.4720.475FalseNoneNoneFalseNoneFalse60021.848250
3596823130996NonePWD SR 2023-24 V-2 Page No-111 It No-12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7737.557737.5540.95FalseNoneNoneFalseNoneFalse316852.67250
3596824130996NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOORKg208.15208.151081.08FalseNoneNoneFalseNoneFalse225026.8020
3596825130996NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3596826130996NonePWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOORKg618.26618.2637.8FalseNoneNoneFalseNoneFalse23370.2280
3596827130996NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm61.9561.9551.48FalseNoneNoneFalseNoneFalse3189.1860
3596828130996NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3596829130996NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm206.91206.9151.48FalseNoneNoneFalseNoneFalse10651.72680
3596830130996NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3596831130996NonePWD SR 2023-24 V11 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6665.668.64FalseNoneNoneFalseNoneFalse567.30240
3596832130996NonePWD SR 2023-24 V11 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOORSqm734.72734.728.64FalseNoneNoneFalseNoneFalse6347.98080
3596833130996NonePWD SR 2023-24 V11 Page No-85 It No-11.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOORKg700.03700.03372.6FalseNoneNoneFalseNoneFalse260831.1780
3596834130996NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOORSqm261.42261.42155.7FalseNoneNoneFalseNoneFalse40703.0940
3596835130996NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOORSqm264.04264.0418.0FalseNoneNoneFalseNoneFalse4752.720
3596836130996NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm315.94315.941940.212FalseNoneNoneFalseNoneFalse612990.579280
3596837130996NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm319.1319.1210.255FalseNoneNoneFalseNoneFalse67092.37050
3596838130996NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm453.47453.47491.752FalseNoneNoneFalseNoneFalse222994.779440
3596839130996NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm458.0458.0212.955FalseNoneNoneFalseNoneFalse97533.390
3596840130996NonePWD SR 2023-24 V11 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm365.5365.5341.085FalseNoneNoneFalseNoneFalse124666.56750
3596841130996NonePWD SR 2023-24 V11 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOORSqm1795.311795.31341.085FalseNoneNoneFalseNoneFalse612353.311350
3596842130996NonePWD SR 2023-24 V11 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOORSqm1418.651418.65472.6FalseNoneNoneFalseNoneFalse670453.990
3596843130996NonePWD SR 2023-24 V11 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOORSqm1101.471101.4748.2FalseNoneNoneFalseNoneFalse53090.8540
3596844130996NonePWD SR 2023-24 V11 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm6601.396601.3926.45FalseNoneNoneFalseNoneFalse174606.76550
3596845130996NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOORSqm4877.944877.9413.0FalseNoneNoneFalseNoneFalse63413.220
3596846130996NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOORSqm4926.724926.721.0FalseNoneNoneFalseNoneFalse4926.720
3596847130996NonePWD SR 2023-24 V11 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3596848130996NonePWD SR 2023-24 V11 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOORm732.24732.242.4FalseNoneNoneFalseNoneFalse1757.3760
3596849130996NonePWD SR 2023-24 V11 Page No-64 It No-9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm5335.135335.1330.0FalseNoneNoneFalseNoneFalse160053.90
3596850130996NonePWD SR 2023-24 V-2 Page No-65 It No-9.4Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOORSqm1154.741154.7418.5FalseNoneNoneFalseNoneFalse21362.690
3596851130996NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. GROUND FLOORSqm2118.692118.69411.1FalseNoneNoneFalseNoneFalse870993.4590
3596852130996NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOORSqm2118.692118.6948.2FalseNoneNoneFalseNoneFalse102120.8580
3596853130996NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOORSqm123.9123.91940.212FalseNoneNoneFalseNoneFalse240392.26680
3596854130996NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOORSqm125.13125.13210.255FalseNoneNoneFalseNoneFalse26309.208150
3596855130996NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm65.6665.662095.912FalseNoneNoneFalseNoneFalse137617.581920
3596856130996NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm66.3266.32228.255FalseNoneNoneFalseNoneFalse15137.87160
3596857130996NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm136.29136.292095.912FalseNoneNoneFalseNoneFalse285651.846480
3596858130996NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm137.65137.65228.255FalseNoneNoneFalseNoneFalse31419.300750
3596859130996NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58491.752FalseNoneNoneFalseNoneFalse106011.896160
3596860130996NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm217.74217.74212.955FalseNoneNoneFalseNoneFalse46368.82170
3596861130996NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOORSqm767.0767.0540.0FalseNoneNoneFalseNoneFalse414180.00
3596862130996NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77876.0FalseNoneNoneFalseNoneFalse71630.520
3596863130996NonePWD SR 2023-24 V-2 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )m42.1242.121278.0FalseNoneNoneFalseNoneFalse53829.360
3596864130996NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOORSqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3596865130996NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORm9.919.91148.8FalseNoneNoneFalseNoneFalse1474.6080
3596866130996NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORm10.0110.014.8FalseNoneNoneFalseNoneFalse48.0480
3596867130996NoneApproved Rate 1Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units. The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system.Sqm2522.62522.655.0FalseNoneNoneFalseNoneFalse138743.00
3596868130996NoneApproved Rate 2Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification.Sqm967.6967.652.0FalseNoneNoneFalseNoneFalse50315.20
3596869130996NoneApproved Rate 3Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Scrub Door /Dirty utility Door (Double leaf) 1.5 mtr X 2.10 mtr Say 3.15 Sq.mtSqm53843.453843.46.3FalseNoneNoneFalseNoneFalse339213.420
3596870130996NoneApproved Rate 4Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be usedSqm3304.03304.055.0FalseNoneNoneFalseNoneFalse181720.00
3596871130996NoneApproved Rate 5Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories.Nos76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
3596872130996NoneApproved Rate 6Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel.Nos33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
3596873130996NoneApproved Rate 7Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel.Nos7080.07080.01.0FalseNoneNoneFalseNoneFalse7080.00
3596874130996NoneApproved Rate 8Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units.Nos70800.070800.02.0FalseNoneNoneFalseNoneFalse141600.00
3596875130996NoneApproved Rate 9Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch.Nos287535.32287535.321.0FalseNoneNoneFalseNoneFalse287535.320
3596876130996NoneApproved Rate 10Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc completeNos7375.07375.01.0FalseNoneNoneFalseNoneFalse7375.00
3596877130996NonePWD SR 2023-24 V2 Page No-131 It No-14.3.1WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOREach7405.57405.511.0FalseNoneNoneFalseNoneFalse81460.50
3596878130996NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOREach2183.02183.011.0FalseNoneNoneFalseNoneFalse24013.00
3596879130996NonePWD SR 2023-24 V-2 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOREach5518.55518.53.0FalseNoneNoneFalseNoneFalse16555.50
3596880130996NonePWD SR 2023-24 V-2 Page No-123 It No-14.34.1Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOREach753.31753.3111.0FalseNoneNoneFalseNoneFalse8286.410
3596881130996NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOREach377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3596882130996NonePWD SR 2023-24 V-2 Page No-70 It No-10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOORSqm3455.573455.572.88FalseNoneNoneFalseNoneFalse9952.04160
3596883130996NonePWD SR 2023-24 V11 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOREach3173.073173.075.0FalseNoneNoneFalseNoneFalse15865.350
3596884130996NoneApproved Rate Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOREach8873.68873.65.0FalseNoneNoneFalseNoneFalse44368.00
3596885130996NonePWD SR 2023-24 V-2 Page No-134 It No-14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOORNos.6296.596296.592.0FalseNoneNoneFalseNoneFalse12593.180
3596886130996NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOORNos.2275.042275.042.0FalseNoneNoneFalseNoneFalse4550.080
3596887130996NonePWD SR 2023-24 V11 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOREach614.54614.5410.0FalseNoneNoneFalseNoneFalse6145.40
3596888130996NonePWD SR 2023-24 V11 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOREach250.27250.2721.0FalseNoneNoneFalseNoneFalse5255.670
3596889130996NonePWD SR 2023-24 V11 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOREach1003.591003.5912.0FalseNoneNoneFalseNoneFalse12043.080
3596890130996NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOREach1261.31261.310.0FalseNoneNoneFalseNoneFalse12613.00
3596891130996NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOREach58.2358.2310.0FalseNoneNoneFalseNoneFalse582.30
3596892130996NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOORm113.98113.9812.0FalseNoneNoneFalseNoneFalse1367.760
3596893130996NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOORm358.07358.0737.0FalseNoneNoneFalseNoneFalse13248.590
3596894130996NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOORm477.01477.0126.0FalseNoneNoneFalseNoneFalse12402.260
3596895130996NonePWD SR 2023-24 V11 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOORm360.54360.5420.0FalseNoneNoneFalseNoneFalse7210.80
3596896130996NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOORm469.58469.5840.0FalseNoneNoneFalseNoneFalse18783.20
3596897130996NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Cold Water Supply GROUND FLOORm591.0591.043.0FalseNoneNoneFalseNoneFalse25413.00
3596898130996NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply GROUND FLOORm690.12690.126.0FalseNoneNoneFalseNoneFalse4140.720
3596899130996NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOORm591.0591.020.0FalseNoneNoneFalseNoneFalse11820.00
3596900130996NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tankm902.25902.25107.0FalseNoneNoneFalseNoneFalse96540.750
3596901130996NonePWD SR 2023-24 V11 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOORNos.1511.581511.585.0FalseNoneNoneFalseNoneFalse7557.90
3596902130996NonePWD SR 2023-24 V-2 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOORLtr11.2611.262000.0FalseNoneNoneFalseNoneFalse22520.00
3596903130996NonePWD SR 2023-24 V11 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOORNos.123.9123.910.0FalseNoneNoneFalseNoneFalse1239.00
3596904130996NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOORNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3596905130996NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHTNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3596906130996NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.1877.081877.087.0FalseNoneNoneFalseNoneFalse13139.560
3596907130996NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.2112.342112.342.0FalseNoneNoneFalseNoneFalse4224.680
3596908130996NonePWD SR 2023-24 V-5 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle FlangesNo.1977.191977.192.0FalseNoneNoneFalseNoneFalse3954.380
3596909130996NonePWD SR 2023-24 V11 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOORNos.387.8387.820.0FalseNoneNoneFalseNoneFalse7756.00
3596910130996NoneOld Sr 2018- 19 Page No- It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOORNos18746.0718746.075.0FalseNoneNoneFalseNoneFalse93730.350
3596911130996NonePWD SR 2023-24 V11 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOORNos.6990.436990.4310.0FalseNoneNoneFalseNoneFalse69904.30
3596912130996NonePWD SR 2023-24 V11 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOORNos.3197.853197.8510.0FalseNoneNoneFalseNoneFalse31978.50
3596913130996NoneApproved Rate 1Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOORNos17700.017700.02.0FalseNoneNoneFalseNoneFalse35400.00
3596914130996NoneApproved Rate 21354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hrNos70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3596915130996NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mSqm299.83299.8340.5FalseNoneNoneFalseNoneFalse12143.1150
3596916130996NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum320.9320.940.5FalseNoneNoneFalseNoneFalse12996.450
3596917130996NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.4710.56FalseNoneNoneFalseNoneFalse13109.92320
3596918130996NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.4510.56FalseNoneNoneFalseNoneFalse15517.3920
3596919130996NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.8810.56FalseNoneNoneFalseNoneFalse15595.85280
3596920130996NonePWD SR 2023-24 V-1I Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge.Cum1659.021659.0237.114FalseNoneNoneFalseNoneFalse61572.868280
3596921130996NonePWD SR 2023-24 V-1I Page No-175 It No-17.6.3Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mmm2325.62325.66.0FalseNoneNoneFalseNoneFalse13953.60
3596922130996NonePWD SR 2023-24 V-1I Page No-176 It No-17.8Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.hr1147.311147.3132.0FalseNoneNoneFalseNoneFalse36713.920
3596923130996NonePWD SR 2023-24 V-1I Page No-176 It No-17.9.3Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm diaEach314.7314.76.0FalseNoneNoneFalseNoneFalse1888.20
3596924130996NonePWD SR 2023-24 V-1I Page No-176 It No-17.11.3Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm diaEach354.35354.356.0FalseNoneNoneFalseNoneFalse2126.10
3596925130996NoneApproved RateProviding and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC ringsEach1121.01121.030.0FalseNoneNoneFalseNoneFalse33630.00
3596926130996NoneData RateProviding and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slabSqm1796.551796.5510.621FalseNoneNoneFalseNoneFalse19081.157550
3596927130996NonePWD SR 2023-24 V- III Page No-9 It No-2.5(ii) ASEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle100 Sqm486.92486.920.168FalseNoneNoneFalseNoneFalse81.802560
3596928130996NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m.Cum126.37126.3742.072FalseNoneNoneFalseNoneFalse5316.638640
3596929130996NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.371.16FalseNoneNoneFalseNoneFalse8607.62920
3596930130996NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7210.609FalseNoneNoneFalseNoneFalse85176.690480
3596931130996NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.877.467FalseNoneNoneFalseNoneFalse5995.030290
3596932130996NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%)Cum4014.364014.363.142FalseNoneNoneFalseNoneFalse12613.119120
3596933130996NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.221.77FalseNoneNoneFalseNoneFalse196181.87940
3596934130996NoneOld SR 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.4115.0FalseNoneNoneFalseNoneFalse5631.150
3596935130996NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5953.41FalseNoneNoneFalseNoneFalse40035.60190
3596936130996NonePWD SR 2023-24 V-2 Page No-42 It No-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm432.41432.4153.41FalseNoneNoneFalseNoneFalse23095.01810
3596937130996NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanizedNo.16284.016284.03.0FalseNoneNoneFalseNoneFalse48852.00
3596938130996NonePWD SR 2023-24 V-2 Page No-176 It No-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1149.791149.796.37FalseNoneNoneFalseNoneFalse7324.16230
3596939130996NonePWD SR 2023-24 V-2 Page No-13 It No-6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum10471.3210471.321.6FalseNoneNoneFalseNoneFalse16754.1120
3596940130996NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.475.6FalseNoneNoneFalseNoneFalse6952.2320
3596941130996NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.455.6FalseNoneNoneFalseNoneFalse8228.920
3596942130996NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.884.0FalseNoneNoneFalseNoneFalse5907.520
3596943130996NonePWD SR 2023-24 V- III Page No-7 It No-2.5(ii)ASUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle100 Sqm486.92486.920.185FalseNoneNoneFalseNoneFalse90.08020
3596944130996NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum126.37126.3723.887FalseNoneNoneFalseNoneFalse3018.600190
3596945130996NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.385FalseNoneNoneFalseNoneFalse17697.582450
3596946130996NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum8028.728028.7210.695FalseNoneNoneFalseNoneFalse85867.16040
3596947130996NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.874.375FalseNoneNoneFalseNoneFalse3512.556250
3596948130996NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete QuantityCum4014.364014.366.32FalseNoneNoneFalseNoneFalse25370.75520
3596949130996NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slabt110837.22110837.221.09FalseNoneNoneFalseNoneFalse120812.56980
3596950130996NoneOld Sr 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.413.0FalseNoneNoneFalseNoneFalse1126.230
3596951130996NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm diaNos16284.016284.01.0FalseNoneNoneFalseNoneFalse16284.00
3596952130996NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5944.6FalseNoneNoneFalseNoneFalse33431.7140
3596953130996NonePWD SR 2023-24 V-2 Page No-42 It No-8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge.Sqm400.19400.1949.1FalseNoneNoneFalseNoneFalse19649.3290
3596954130996NonePWD SR 2023-24 Volume 6 It No-2.2.1INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.4210.0FalseNoneNoneFalseNoneFalse3174.20
3596955130996NonePWD SR 2023-24 Volume 6 It No-2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2222.0FalseNoneNoneFalseNoneFalse9838.840
3596956130996NonePWD SR 2023-24 Volume 6 It No-2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.960.0FalseNoneNoneFalseNoneFalse39294.00
3596957130996NonePWD SR 2023-24 Volume 6 It No-2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.8616.0FalseNoneNoneFalseNoneFalse12781.760
3596958130996NonePWD SR 2023-24 Volume 6 It No-2.2.5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switchesPoint1167.021167.0210.0FalseNoneNoneFalseNoneFalse11670.20
3596959130996NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 WayEach121.54121.542.0FalseNoneNoneFalseNoneFalse243.080
3596960130996NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 WayEach146.32146.322.0FalseNoneNoneFalseNoneFalse292.640
3596961130996NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5WayEach161.66161.663.0FalseNoneNoneFalseNoneFalse484.980
3596962130996NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach204.14204.144.0FalseNoneNoneFalseNoneFalse816.560
3596963130996NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 WayEach258.42258.422.0FalseNoneNoneFalseNoneFalse516.840
3596964130996NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 WayEach162.84162.8418.0FalseNoneNoneFalseNoneFalse2931.120
3596965130996NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 WayEach187.62187.6230.0FalseNoneNoneFalseNoneFalse5628.60
3596966130996NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5WayEach208.86208.8622.0FalseNoneNoneFalseNoneFalse4594.920
3596967130996NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 WayEach259.6259.638.0FalseNoneNoneFalseNoneFalse9864.80
3596968130996NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 WayEach307.98307.9826.0FalseNoneNoneFalseNoneFalse8007.480
3596969130996NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 WayEach376.42376.428.0FalseNoneNoneFalseNoneFalse3011.360
3596970130996NonePWD SR 2023-24 Volume 6 It No-3.4.7Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 WayEach428.34428.346.0FalseNoneNoneFalseNoneFalse2570.040
3596971130996NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 ModuleEach161.66161.6620.0FalseNoneNoneFalseNoneFalse3233.20
3596972130996NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 ModuleEach189.98189.9832.0FalseNoneNoneFalseNoneFalse6079.360
3596973130996NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 ModuleEach206.5206.525.0FalseNoneNoneFalseNoneFalse5162.50
3596974130996NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 ModuleEach276.12276.1242.0FalseNoneNoneFalseNoneFalse11597.040
3596975130996NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 ModuleEach335.12335.1228.0FalseNoneNoneFalseNoneFalse9383.360
3596976130996NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12ModuleEach405.92405.928.0FalseNoneNoneFalseNoneFalse3247.360
3596977130996NonePWD SR 2023-24 Volume 6 It No-3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 ModuleEach468.46468.466.0FalseNoneNoneFalseNoneFalse2810.760
3596978130996NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switchEach120.36120.36210.0FalseNoneNoneFalseNoneFalse25275.60
3596979130996NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switchEach195.88195.8810.0FalseNoneNoneFalseNoneFalse1958.80
3596980130996NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way socketsEach201.78201.78108.0FalseNoneNoneFalseNoneFalse21792.240
3596981130996NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator'sEach421.26421.2640.0FalseNoneNoneFalseNoneFalse16850.40
3596982130996NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.4838.0FalseNoneNoneFalseNoneFalse10582.240
3596983130996NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.438.0FalseNoneNoneFalseNoneFalse8071.20
3596984130996NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3596985130996NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3596986130996NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bellEach290.28290.282.0FalseNoneNoneFalseNoneFalse580.560
3596987130996NonePWD SR 2023-24 Volume 6 It No-13.12Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.4640.0FalseNoneNoneFalseNoneFalse9298.40
3596988130996NonePWD SR 2023-24 Volume 6 It No-1.13Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hookEach138.06138.0640.0FalseNoneNoneFalseNoneFalse5522.40
3596989130996NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.881150.0FalseNoneNoneFalseNoneFalse89562.00
3596990130996NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.041350.0FalseNoneNoneFalseNoneFalse124254.00
3596991130996NonePWD SR 2023-24 Volume 6 It No-1.2.3Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thickm121.54121.54265.0FalseNoneNoneFalseNoneFalse32208.10
3596992130996NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.24210.0FalseNoneNoneFalseNoneFalse16850.40
3596993130996NonePWD SR 2023-24 Volume 6 It No-1.3.2Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.22350.0FalseNoneNoneFalseNoneFalse32627.00
3596994130996NonePWD SR 2023-24 Volume 6 It No-1.3.3Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.8240.0FalseNoneNoneFalseNoneFalse4672.80
3596995130996NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.82110.0FalseNoneNoneFalseNoneFalse6360.20
3596996130996NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction boxEach66.0866.08160.0FalseNoneNoneFalseNoneFalse10572.80
3596997130996NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction boxEach71.9871.9820.0FalseNoneNoneFalseNoneFalse1439.60
3596998130996NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mmm30.6830.681750.0FalseNoneNoneFalseNoneFalse53690.00
3596999130996NonePWD SR 2023-24 Volume 6 It No-2.3.3FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.562480.0FalseNoneNoneFalseNoneFalse122908.80
3597000130996NonePWD SR 2023-24 Volume 6 It No-2.3.4FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mmm74.3474.34950.0FalseNoneNoneFalseNoneFalse70623.00
3597001130996NonePWD SR 2023-24 Volume 6 It No-2.3.5FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.56280.0FalseNoneNoneFalseNoneFalse30396.80
3597002130996NonePWD SR 2023-24 Volume 6 It No-2.3.6FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mmm197.06197.06160.0FalseNoneNoneFalseNoneFalse31529.60
3597003130996NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.54220.0FalseNoneNoneFalseNoneFalse778.80
3597004130996NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.72310.0FalseNoneNoneFalseNoneFalse1463.20
3597005130996NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2680.0FalseNoneNoneFalseNoneFalse660.80
3597006130996NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.2624.0FalseNoneNoneFalseNoneFalse198.240
3597007130996NoneMR 5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmmEach9.449.4418.0FalseNoneNoneFalseNoneFalse169.920
3597008130996NonePWD SR 2023-24 Volume 6 It No-5.19.11Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & NEach4764.844764.843.0FalseNoneNoneFalseNoneFalse14294.520
3597009130996NonePWD SR 2023-24 Volume 6 It No-5.19.12Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & NEach5829.25829.22.0FalseNoneNoneFalseNoneFalse11658.40
3597010130996NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.223.0FalseNoneNoneFalseNoneFalse8244.660
3597011130996NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SPEach489.7489.786.0FalseNoneNoneFalseNoneFalse42114.20
3597012130996NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3597013130996NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPNEach3643.843643.846.0FalseNoneNoneFalseNoneFalse21863.040
3597014130996NonePWD SR 2023-24 Volume 6 It No-5.20.4Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 poleEach5379.625379.623.0FalseNoneNoneFalseNoneFalse16138.860
3597015130996NonePWD SR 2023-24 Volume 6 It No-5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 poleEach6543.16543.12.0FalseNoneNoneFalseNoneFalse13086.20
3597016130996NonePWD SR 2023-24 Volume 6 It No-5.17.3Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 WayEach18324.2218324.221.0FalseNoneNoneFalseNoneFalse18324.220
3597017130996NonePWD SR 2023-24 Volume 6 It No-5.15.9Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kAEach10014.6610014.661.0FalseNoneNoneFalseNoneFalse10014.660
3597018130996NonePWD SR 2023-24 Volume 6 It No-5.5.2Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63AEach4953.584953.581.0FalseNoneNoneFalseNoneFalse4953.580
3597019130996NonePWD SR 2023-24 Volume 6 It No-5.5.3Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 100AEach8934.288934.282.0FalseNoneNoneFalseNoneFalse17868.560
3597020130996NoneMR 6Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m548.7548.720.0FalseNoneNoneFalseNoneFalse10974.00
3597021130996NoneMR 7Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m719.8719.825.0FalseNoneNoneFalseNoneFalse17995.00
3597022130996NonePWD SR 2023-24 Volume 6 It No-11.3.1TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach650.18650.184.0FalseNoneNoneFalseNoneFalse2600.720
3597023130996NonePWD SR 2023-24 Volume 6 It No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach814.2814.250.0FalseNoneNoneFalseNoneFalse40710.00
3597024130996NonePWD SR 2023-24 Volume 6 It No-11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach1044.31044.312.0FalseNoneNoneFalseNoneFalse12531.60
3597025130996NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.3234.0FalseNoneNoneFalseNoneFalse53118.880
3597026130996NonePWD SR 2023-24 Volume 6 It No-11.6.3Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36WNo5372.545372.5412.0FalseNoneNoneFalseNoneFalse64470.480
3597027130996NoneMR 8Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.012.0FalseNoneNoneFalseNoneFalse6372.00
3597028130996NoneMR 9Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.010.0FalseNoneNoneFalseNoneFalse19470.00
3597029130996NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.5610.0FalseNoneNoneFalseNoneFalse17605.60
3597030130996NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm)Each3158.863158.8640.0FalseNoneNoneFalseNoneFalse126354.40
3597031130996NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.96112.0FalseNoneNoneFalseNoneFalse16123.520
3597032130996NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7840.0FalseNoneNoneFalseNoneFalse8071.20
3597033130996NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.5610.0FalseNoneNoneFalseNoneFalse5805.60
3597034130996NonePWD SR 2023-24 Volume 6 It No-5.42.2Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59210000.0FalseNoneNoneFalseNoneFalse123900.00
3597035130996NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Stripsm4053.34053.37.0FalseNoneNoneFalseNoneFalse28373.10
3597036130996NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.916.0FalseNoneNoneFalseNoneFalse5758.40
3597037130996NonePWD SR 2023-24 Volume 6 It No-5.51.3Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATSEach109922.9109922.91.0FalseNoneNoneFalseNoneFalse109922.90
3597038130996NonePWD SR 2023-24 Volume 6 It No-5.15.15Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kAEach27783.127783.11.0FalseNoneNoneFalseNoneFalse27783.10
3597039130996NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3597040130996NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.8410.0FalseNoneNoneFalseNoneFalse36438.40
3597041130996NonePWD SR 2023-24 Volume 6 It No-5.15.10Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kAEach12202.3812202.386.0FalseNoneNoneFalseNoneFalse73214.280
3597042130996NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kAEach15867.4615867.462.0FalseNoneNoneFalseNoneFalse31734.920
3597043130996NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3597044130996NonePWD SR 2023-24 Volume 6 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3597045130996NonePWD SR 2023-24 Volume 6 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3597046130996NonePWD SR 2023-24 Volume 6 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3597047130996NonePWD SR 2023-24 Volume 6 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3597048130996NonePWD SR 2023-24 Volume 6 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3597049130996NonePWD SR 2023-24 Volume 6 It No-5.29Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterEach1681.51681.51.0FalseNoneNoneFalseNoneFalse1681.50
3597050130996NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6860.0FalseNoneNoneFalseNoneFalse1840.80
3597051130996NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3597052130996NonePWD SR 2023-24 Volume 6 It No-2.3.7WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2m375.24375.2455.0FalseNoneNoneFalseNoneFalse20638.20
3597053130996NonePWD SR 2023-24 Volume 6 It No-5.42.2APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59115000.0FalseNoneNoneFalseNoneFalse67850.00
3597054130996NonePWD SR 2023-24 Volume 6 It No-5.39Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsEach25535.225535.21.0FalseNoneNoneFalseNoneFalse25535.20
3597055130996NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3597056130996NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole IncomersEach15867.4615867.461.0FalseNoneNoneFalseNoneFalse15867.460
3597057130996NonePWD SR 2023-24 Volume 6 It No-5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TPEach946.36946.368.0FalseNoneNoneFalseNoneFalse7570.880
3597058130996NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.910.0FalseNoneNoneFalseNoneFalse3599.00
3597059130996NonePWD SR 2023-24 Volume 6 It No-5.4.2Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAREach252.52252.524.0FalseNoneNoneFalseNoneFalse1010.080
3597060130996NonePWD SR 2023-24 Volume 6 It No-5.4.3Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAREach405.92405.921.0FalseNoneNoneFalseNoneFalse405.920
3597061130996NoneMR 10ILPB Type push button with Lanmp - ON/OFF(L&T Make)Each413.0413.016.0FalseNoneNoneFalseNoneFalse6608.00
3597062130996NonePWD SR 2023-24 Volume 6 It No-5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 AEach1522.21522.26.0FalseNoneNoneFalseNoneFalse9133.20
3597063130996NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3597064130996NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3597065130996NonePWD SR 2023-24 Volume 6 It No-5.34Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current TransformerEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3597066130996NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2m30.6830.6840.0FalseNoneNoneFalseNoneFalse1227.20
3597067130996NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3597068130996NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2m74.3474.3435.0FalseNoneNoneFalseNoneFalse2601.90
3597069130996NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2m375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3597070130996NonePWD SR 2023-24 Volume 6 It No-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core.Km167373.56167373.560.1FalseNoneNoneFalseNoneFalse16737.3560
3597071130996NonePWD SR 2023-24 Volume 6 It No-32.09Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core.Km181793.16181793.160.04FalseNoneNoneFalseNoneFalse7271.72640
3597072130996NonePWD SR 2023-24 Volume 6 It No-32.14Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core.Km440393.7440393.70.12FalseNoneNoneFalseNoneFalse52847.2440
3597073130996NonePWD SR 2023-24 Volume 6 It No-2.3.7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Corem375.24375.2460.0FalseNoneNoneFalseNoneFalse22514.40
3597074130996NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm24645.4824645.480.14FalseNoneNoneFalseNoneFalse3450.36720
3597075130996NonePWD SR 2023-24 Volume 6 It No-21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm36744.0236744.020.12FalseNoneNoneFalseNoneFalse4409.28240
3597076130996NonePWD SR 2023-24 Volume 6 It No-6.11.1Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mmEach80.2480.2410.0FalseNoneNoneFalseNoneFalse802.40
3597077130996NonePWD SR 2023-24 Volume 6 It No-6.11.2Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm diaEach99.1299.128.0FalseNoneNoneFalseNoneFalse792.960
3597078130996NonePWD SR 2023-24 Volume 6 It No-6.11.3Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm diaEach138.06138.068.0FalseNoneNoneFalseNoneFalse1104.480
3597079130996NonePWD SR 2023-24 Volume 6 It No-63.02Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 GmNo48.3848.3818.0FalseNoneNoneFalseNoneFalse870.840
3597080130996NonePWD SR 2023-24 Volume 6 It No-63.05Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 GmNo156.94156.9418.0FalseNoneNoneFalseNoneFalse2824.920
3597081130996NonePWD SR 2023-24 Volume 6 It No-12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound.Each5343.045343.042.0FalseNoneNoneFalseNoneFalse10686.080
3597082130996NonePWD SR 2023-24 Volume 6 It No-12.60.3Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound.Each10022.9210022.922.0FalseNoneNoneFalseNoneFalse20045.840
3597083130996NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.86.0FalseNoneNoneFalseNoneFalse24850.80
3597084130996NonePWD SR 2023-24 Volume 6 It No-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each5022.085022.084.0FalseNoneNoneFalseNoneFalse20088.320
3597085130996NonePWD SR 2023-24 Volume 6 It No-12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI stripm151.04151.04120.0FalseNoneNoneFalseNoneFalse18124.80
3597086130996NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.56.0FalseNoneNoneFalseNoneFalse6195.00
3597087130996NonePWD SR 2023-24 Volume 6 It No-12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper stripm672.6672.650.0FalseNoneNoneFalseNoneFalse33630.00
3597088130996NonePWD SR 2023-24 Volume 6 It No-12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3597089130996NonePWD SR 2023-24 Volume 6 It No-6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem22.4222.42110.0FalseNoneNoneFalseNoneFalse2466.20
3597090130996NonePWD SR 2023-24 Volume 6 It No-6.18.6Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire.m123.9123.9220.0FalseNoneNoneFalseNoneFalse27258.00
3597091130996NoneMR 11CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets.Nos.17700.017700.06.0FalseNoneNoneFalseNoneFalse106200.00
3597092130996NoneMR 12Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets.Nos.25960.025960.03.0FalseNoneNoneFalseNoneFalse77880.00
3597093130996NoneMR 13NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz.Nos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3597094130996NoneMR 144TB HDD (Surveillance or Enterprise Grade)Nos.17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3597095130996NoneMR 1516 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature supportNos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3597096130996NonePWD SR 2023-24 Volume 6 It No-8.12.6Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panelNos.9145.09145.01.0FalseNoneNoneFalseNoneFalse9145.00
3597097130996NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableNos.303.26303.2613.0FalseNoneNoneFalseNoneFalse3942.380
3597098130996NoneMR 16Rj 45 connector with Crimping with 4 x 4 PVC boxesSet192.34192.3411.0FalseNoneNoneFalseNoneFalse2115.740
3597099130996NonePWD SR 2023-24 Volume 6 It No-8.4.3Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depthNos.10001.6810001.681.0FalseNoneNoneFalseNoneFalse10001.680
3597100130996NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripNos.1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3597101130996NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfNos.975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3597102130996NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanNos.1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3597103130996NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04265.0FalseNoneNoneFalseNoneFalse24390.60
3597104130996NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84390.0FalseNoneNoneFalseNoneFalse17487.60
3597105130996NoneMR 17Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required)Each35400.035400.01.0FalseNoneNoneFalseNoneFalse35400.00
3597106130996NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84650.0FalseNoneNoneFalseNoneFalse29146.00
3597107130996NonePWD SR 2023-24 Volume 6 It No-8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pairm24.7824.78320.0FalseNoneNoneFalseNoneFalse7929.60
3597108130996NonePWD SR 2023-24 Volume 6 It No-8.4.4Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depthNos.10425.310425.31.0FalseNoneNoneFalseNoneFalse10425.30
3597109130996NonePWD SR 2023-24 Volume 6 It No-8.9.10Supplying fixing of Networking Switches 24 Port 10/100/1000 SwitchEach8749.78749.71.0FalseNoneNoneFalseNoneFalse8749.70
3597110130996NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripEach1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3597111130996NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfEach975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3597112130996NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanEach1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3597113130996NonePWD SR 2023-24 Volume 6 It No-8.10.1Supplying &fixing of I/Osocket, face plate with back box Single I/OEach578.2578.28.0FalseNoneNoneFalseNoneFalse4625.60
3597114130996NonePWD SR 2023-24 Volume 6 It No-8.10.2Supplying &fixing of I/Osocket, face plate with back box Double I/OEach649.0649.015.0FalseNoneNoneFalseNoneFalse9735.00
3597115130996NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableEach303.26303.2622.0FalseNoneNoneFalseNoneFalse6671.720
3597116130996NonePWD SR 2023-24 Volume 6 It No-8.11.3Supplying &fixing of 3mtr cat 6 Patch CableEach390.58390.5822.0FalseNoneNoneFalseNoneFalse8592.760
3597117130996NonePWD SR 2023-24 Volume 6 It No-8.12.5Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panelEach9322.09322.01.0FalseNoneNoneFalseNoneFalse9322.00
3597118130996NonePWD SR 2023-24 Volume 6 It No-3.6.11Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socketEach184.08184.086.0FalseNoneNoneFalseNoneFalse1104.480
3597119130996NonePWD SR 2023-24 Volume 6 It No-8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.m51.9251.92180.0FalseNoneNoneFalseNoneFalse9345.60
3597120130996NonePWD SR 2023-24 Volume 6 It No-8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOXEach451.94451.941.0FalseNoneNoneFalseNoneFalse451.940
3597121130996NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04450.0FalseNoneNoneFalseNoneFalse41418.00
3597122130996NoneMR 18Supply & Fixing of GbESpeed Wifi Router, PoE Support.Each11800.011800.02.0FalseNoneNoneFalseNoneFalse23600.00
3597123130996NoneMR 198 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 NosEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3597124130996NoneMR 20EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue ExtensionsNos112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3597125130996NoneMR 2110 line IPM with LED IndicationsNos2950.02950.02.0FalseNoneNoneFalseNoneFalse5900.00
3597126130996NoneMR 22Analog PhonesNos2065.02065.015.0FalseNoneNoneFalseNoneFalse30975.00
3597127130996NoneMR 23Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A.Nos41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3597128130996NoneMR 24Supply & Fixing of PC , T & A Software,Nos64900.064900.01.0FalseNoneNoneFalseNoneFalse64900.00
3597129130996NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cableNos44.8444.8450.0FalseNoneNoneFalseNoneFalse2242.00
3597130130996NoneCSR 23-24 Page No-20 It No-45.04EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 SqmmSet4417.924417.926.0FalseNoneNoneFalseNoneFalse26507.520
3597131130996NoneCSR 23-24 Page No-20 It No-45.07Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE CableSet4799.064799.062.0FalseNoneNoneFalseNoneFalse9598.120
3597132130996NoneCSR 23-24 Page No-52 It No-22.04Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 SqmmNo3136.443136.448.0FalseNoneNoneFalseNoneFalse25091.520
3597133130996NoneCSR 23-24 Page No-15 It No-36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)Km1049805.881049805.880.12FalseNoneNoneFalseNoneFalse125976.70560
3597134130996NoneCSR 23-24 Page No-52 It No-21.01Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 SqmmKm72359.9672359.960.12FalseNoneNoneFalseNoneFalse8683.19520
3597135130996NoneCSR 23-24 Page No-16 It No-39.01Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing)Unit648469.0648469.01.0FalseNoneNoneFalseNoneFalse648469.00
3597136130996NoneCSR 23-24 Page No-26 It No-58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)Unit287296.96287296.961.0FalseNoneNoneFalseNoneFalse287296.960
3597137130996NoneCSR 23-24 Page No-23 It No-53.1HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT featuresNo16344.1816344.183.0FalseNoneNoneFalseNoneFalse49032.540
3597138130996NoneCSR 23-24 Page No-23 It No-53.02CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering)No23558.723558.73.0FalseNoneNoneFalseNoneFalse70676.10
3597139130996NoneCSR 23-24 Page No-17 It No-41.01Load Break Switch with PanelNo86422.0286422.021.0FalseNoneNoneFalseNoneFalse86422.020
3597140130996NoneCSR 23-24 Page No-7 It No-12.16Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPENo268217.54268217.541.0FalseNoneNoneFalseNoneFalse268217.540
3597141130996NoneCSR 21-22 Page No-2 0f 14 It No-4.06Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.No35825.9835825.982.0FalseNoneNoneFalseNoneFalse71651.960
3597142130996NoneCSR 21-22 Page No-22 It No-4.06 a)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 KgsNo1732.241732.244.0FalseNoneNoneFalseNoneFalse6928.960
3597143130996NoneCSR 21-22 Page No-4 of 4 It No-4.06 b)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs Rod TypeSet3418.463418.464.0FalseNoneNoneFalseNoneFalse13673.840
3597144130996NoneChapter-12 Page No-55 It No-12.60.3Using 10ft. Copper bonded rod with backfill compound.No10022.9210022.924.0FalseNoneNoneFalseNoneFalse40091.680
3597145130996NoneCSR 21-22 Page No-22 It No-51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo797.68797.6812.0FalseNoneNoneFalseNoneFalse9572.160
3597146130996NoneCSR 21-22 Page No-22 It No-51.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag365.8365.812.0FalseNoneNoneFalseNoneFalse4389.60
3597147130996NoneCSR 23-24 Page No-23 It No-51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNo2562.962562.9610.0FalseNoneNoneFalseNoneFalse25629.60
3597148130996NoneCSR 23-24 Page No-23 It No-51.05Bentonite clay slurry for earthing in 50 Kg BagBag434.24434.2410.0FalseNoneNoneFalseNoneFalse4342.40
3597149130996NoneCSR 23-24 Page No-23 It No-55.01Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 MtrNo610.06610.065.0FalseNoneNoneFalseNoneFalse3050.30
3597150130996NonePage No-43 It No-1.6.1Digging of Pit for providing GI Pipe type Earthing Ordinary SoilNo895.62895.6210.0FalseNoneNoneFalseNoneFalse8956.20
3597151130996NonePage No-43 It No-1.6.2Digging of Pit for providing GI Pipe type Earthing Hard SoilNo3528.23528.24.0FalseNoneNoneFalseNoneFalse14112.80
3597152130996NoneChapter-5 Page No-20 It No-5.42.1Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.5935000.0FalseNoneNoneFalseNoneFalse20650.00
3597153130996NoneChapter-5 Page No-20 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3597154130996NoneChapter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mmm654.9654.912.0FalseNoneNoneFalseNoneFalse7858.80
3597155130996NoneChapter-5 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KAEach25241.3825241.381.0FalseNoneNoneFalseNoneFalse25241.380
3597156130996NoneChapter-5 Page No-17 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3597157130996NoneChapter-5 Page No-18 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS ConnectivityEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3597158130996NoneChapter-5 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3597159130996NoneChapter-5 Page No-18 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3597160130996NoneChapter-5 Page No-18 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3597161130996NoneChapter-5 Page No-18 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3597162130996NoneChapter-5 Page No-19 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
3597163130996NoneChapter-5 Page No-19 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.82.0FalseNoneNoneFalseNoneFalse377.60
3597164130996NoneChapter-2 Page No-5 It No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6825.0FalseNoneNoneFalseNoneFalse767.00
3597165130996NoneChapter-2 Page No-5 It No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5610.0FalseNoneNoneFalseNoneFalse495.60
3597166130996NoneLeast Quotation RateSupplying, fixing and wiring 3 Phase TVSSEach16520.016520.01.0FalseNoneNoneFalseNoneFalse16520.00
3597167130996NoneCSR 21-22 Page No-23 of 27 It No-66.01Cable Covering Tile 125x250x40 mmPer Km11800.011800.01.0FalseNoneNoneFalseNoneFalse11800.00
3597168130996NoneCSR 21-22 Page No-23 of 27 It No-66.02Cable Covering Tile 125x125x40 mmPer Km5900.05900.01.0FalseNoneNoneFalseNoneFalse5900.00
3597169130996NoneCSR 21-22 Page No-23 of 27 It No-66.03RCC Hume Pipe 2000 mm long 150 mm DiaNo354.0354.08.0FalseNoneNoneFalseNoneFalse2832.00
3597170130996NoneCSR 21-22 Page No-23 of 27 It No-66.04RCC Hume Pipe 2000 mm long 200 mm DiaNo448.4448.410.0FalseNoneNoneFalseNoneFalse4484.00
3597171130996NoneCSR 21-22 Page No-23 of 27 It No-66.05Collars for RCC Hume Pipe 150 mm DiaNo94.494.44.0FalseNoneNoneFalseNoneFalse377.60
3597172130996NoneCSR 21-22 Page No-23 of 27 It No-66.06Collars for RCC Hume Pipe 200 mm DiaNo118.0118.04.0FalseNoneNoneFalseNoneFalse472.00
3597173130996NoneCSR 21-22 Page No-23 of 27 It No-66.19Route & Joint indicating slab with MS Anchor rodNo153.4153.45.0FalseNoneNoneFalseNoneFalse767.00
3597174130996NoneCSR 21-22 Page No-23 of 27 It No-66.20Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 MtrRoll149.86149.865.0FalseNoneNoneFalseNoneFalse749.30
3597175130996NoneCSR 21-22 Page No-23 of 27 It No-66.21Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 MtrRoll138.06138.065.0FalseNoneNoneFalseNoneFalse690.30
3597176130996NonePage No-3 of 4 It No-XXVSpiral Earth ElectrodeSet375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3597177130996NonePage No-3 of 4 It No-XXVIICaution/Danger BoardNo234.82234.822.0FalseNoneNoneFalseNoneFalse469.640
3597178130996NoneChpter-12 Page No-54 It No-12.58.225x3mm GI stripm96.7696.7680.0FalseNoneNoneFalseNoneFalse7740.80
3597179130996NoneChpter-12 Page No-54 It No-12.58.325x6mm GI stripm151.04151.0460.0FalseNoneNoneFalseNoneFalse9062.40
3597180130996NoneChpter-12 Page No-55 It No-12.58.6600x600x3mm GI PlateEach1032.51032.510.0FalseNoneNoneFalseNoneFalse10325.00
3597181130996NoneChpter-12 Page No-55 It No-12.58.725x3mm Copper stripm672.6672.660.0FalseNoneNoneFalseNoneFalse40356.00
3597182130996NoneChpter-12 Page No-55 It No-12.58.11600x600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3597183130996NoneLeast Quotation Rate 1Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate).m1593.01593.030.0FalseNoneNoneFalseNoneFalse47790.00
3597184130996NoneLeast Quotation Rate 2Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,Sqm1003.01003.010.0FalseNoneNoneFalseNoneFalse10030.00
3597185130996NoneChpter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mmm654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3597186130996NoneLeast Quotation Rate 3Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yardSqm826.0826.016.0FalseNoneNoneFalseNoneFalse13216.00
3597187130996NoneLeast Quotation Rate 4Supplying of two bucket stand alongwith buckets. CompleteEach743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3597188130996NoneLeast Quotation Rate 5Rubber Hand Gloves 15 kV,SEAMLESS Confirming to ISPair200.6200.62.0FalseNoneNoneFalseNoneFalse401.20
3597189130996NoneCSR 21-22 Page No- It No-21 OF 27Supplying of first aid box. CompleteEach1300.361300.362.0FalseNoneNoneFalseNoneFalse2600.720
3597190130996NoneLeast Quotation Rate 7Supplying of FIRST AID CHART with lamination. CompleteEach265.5265.52.0FalseNoneNoneFalseNoneFalse531.00
3597191130996NonePWD SR 2023-24 Volume 6 It No-9.3.5UPS Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPSEach122212.6122212.61.0FalseNoneNoneFalseNoneFalse122212.60
3597192130996NonePWD SR 2023-24 Volume 6 It No-9.5.8Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacityEach18306.5218306.5216.0FalseNoneNoneFalseNoneFalse292904.320
3597193130996NonePWD SR 2023-24 Volume 6 It No-6.9.5HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 PhNo166680.9166680.92.0FalseNoneNoneFalseNoneFalse333361.80
3597194130996NonePWD SR 2023-24 Volume 6 It No-6.13.2Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tubem2080.342080.3420.0FalseNoneNoneFalseNoneFalse41606.80
3597195130996NonePWD SR 2023-24 Volume 6 It No-6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.Each5877.585877.582.0FalseNoneNoneFalseNoneFalse11755.160
3597196130996NonePWD SR 2023-24 Volume 6 It No-6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.Each5398.55398.52.0FalseNoneNoneFalseNoneFalse10797.00
3597197130996NonePWD SR 2023-24 Volume 6 It No-4.4.5STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm diaEach17700.017700.04.0FalseNoneNoneFalseNoneFalse70800.00
3597198130996NonePWD SR 2023-24 Volume 6 It No-4.6.1Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM diaEach2006.02006.04.0FalseNoneNoneFalseNoneFalse8024.00
3597199130996NonePWD SR 2023-24 Volume 6 It No-11.8.3LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70wattsEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3597200130996NonePWD SR 2023-24 Volume 6 It No-13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Each191.16191.164.0FalseNoneNoneFalseNoneFalse764.640
3597201130996NonePWD SR 2023-24 Volume 6 It No-32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km139244.72139244.720.15FalseNoneNoneFalseNoneFalse20886.7080
3597202130996NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 SqmmKm24645.4824645.480.15FalseNoneNoneFalseNoneFalse3696.8220
3597203130996NonePWD SR 2023-24 Volume 6 It No-2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmmm133.34133.34210.0FalseNoneNoneFalseNoneFalse28001.40
3597204130996NonePWD SR 2023-24 Volume 6 It No-2.5.15Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmmm202.96202.96150.0FalseNoneNoneFalseNoneFalse30444.00
3597205130996NoneMR 1Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM IDm300.9300.920.0FalseNoneNoneFalseNoneFalse6018.00
3597206130996NonePWD SR 2023-24 Volume 6 It No-6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 )m89.6889.68150.0FalseNoneNoneFalseNoneFalse13452.00
3597207130996NonePWD SR 2023-24 Volume 6 It No-6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 )m118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3597208130996NonePWD SR 2023-24 Volume 6 It No-11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70WEach7986.247986.246.0FalseNoneNoneFalseNoneFalse47917.440
3597209130996NonePWD SR 2023-24 Volume 6 It No-11.7.2Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 WattsEach9111.969111.966.0FalseNoneNoneFalseNoneFalse54671.760
3597210130996NonePWD SR 2023-24 V-3 Page No-9 It No-2.5ACC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.05FalseNoneNoneFalseNoneFalse511.2660
3597211130996NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.7117.731.5FalseNoneNoneFalseNoneFalse3707.550
3597212130996NonePWD SR 2023-24 V-3 Page No-17 It No-305.3.4Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum130.09130.0931.5FalseNoneNoneFalseNoneFalse4097.8350
3597213130996NonePWD SR 2023-24 VI Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.28587.2831.5FalseNoneNoneFalseNoneFalse18499.320
3597214130996NonePWD SR 2023-24 V-3 Page No-23 It No-4.2(v)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V MaterialCum2922.82922.815.75FalseNoneNoneFalseNoneFalse46034.10
3597215130996NonePWDSR 2023-24 V-3 Page No-49 It No6.1Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.Cum6095.886095.8810.5FalseNoneNoneFalseNoneFalse64006.740
3597216130996NonePWDSR 2023-24 V-3 Page No-43 (7) It No6.2Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawingCum11107.6311107.6321.0FalseNoneNoneFalseNoneFalse233260.230
3597217130996NonePageNo56 It No-8.10 MoRTH 803Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesSqm105.31105.3115.0FalseNoneNoneFalseNoneFalse1579.650
3597218130996NonePageNo123 It No-13.14MoRTH 800Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.Sqm87.9687.96448.0FalseNoneNoneFalseNoneFalse39406.080
3597219130996NonePWD SR 2023-24 V-3 Page No-146 It No-21A(6.1)Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stonem296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3597220130996NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.25FalseNoneNoneFalseNoneFalse16695.83250
3597221130996NonePWD Volume- 2 SR 2023-24 Page No-6 It No-1.5COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4677.15FalseNoneNoneFalseNoneFalse28580.9890
3597222130996NonePWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3713.64FalseNoneNoneFalseNoneFalse101213.84680
3597223130996NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing ConcreteCum8412.768412.768.7FalseNoneNoneFalseNoneFalse73191.0120
3597224130996NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column ConcreteCum13242.3113242.318.02FalseNoneNoneFalseNoneFalse106203.32620
3597225130996NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam ConcreteCum13242.3113242.318.01FalseNoneNoneFalseNoneFalse106070.90310
3597226130996NonePWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.222.55FalseNoneNoneFalseNoneFalse282634.9110
3597227130996NonePWD Volume- 2 SR 2023-24 Page No-17 It No-6.33roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1525.211525.21137.58FalseNoneNoneFalseNoneFalse209838.39180
3597228130996NonePWD Volume- 2 SR 2023-24 Page No-42 It No-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm459.67459.67370.16FalseNoneNoneFalseNoneFalse170151.44720
3597229130996NonePWD Volume- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28370.16FalseNoneNoneFalseNoneFalse71544.52480
3597230130996NonePWD SR 2023-24 V-5 Page No-140 It No-12.4BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in chargeNos6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3597231130996NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrsm458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3597232130996NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr.m574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3597233130996NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr.m610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3597234130996NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr.m708.71708.7130.0FalseNoneNoneFalseNoneFalse21261.30
3597235130996NonePWD SR 2023-24 V-5 Page No-143 It No-12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m2394.992394.9925.0FalseNoneNoneFalseNoneFalse59874.750
3597236130996NonePWD SR 2023-24 V-5 Page No-155 It No-13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsm681.45681.45200.0FalseNoneNoneFalseNoneFalse136290.00
3597237130996NonePWD SR 2023-24 V-5 Page No-143 It No-12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3597238130996NonePWD SR 2023-24 V-5 Page No-154 It No-12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3597239130996NonePWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3597240130996NonePWD SR 2023-24 V-5 Page No-154 It No-13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"Nos34832.0134832.011.0FalseNoneNoneFalseNoneFalse34832.010
3597241130996NonePWD SR 2023-24 V-5 Page No-155 It No-13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Nos11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3597242130996NonePWD SR 2023-24 V-5 Page No-155 It No-13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3597243130996NonePWD SR 2023-24 V-5 Page No-155 It No-13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3597244130996NonePWD SR 2023-24 V-5 Page No-156 It No-13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3597245130996NonePWD SR 2023 24 V 5 Page No-156 It No 13.34Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Each1796.551796.551.0FalseNoneNoneFalseNoneFalse1796.550
3597246130996NonePWD SR 2023 24 Page No Ele SrP No 12, It No2.11.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10)m121.42121.42259.0FalseNoneNoneFalseNoneFalse31447.780
3597247130996NonePWD SR 2023-24 V-5 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWGSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3597248130996NonePWD SR 2023-24 V-5 Page No-21 It No-5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm.Nos17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3597249130996NonePWD SR 2023-24 Vol-6 It No-I No 6.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-chargeNos361.79361.791.0FalseNoneNoneFalseNoneFalse361.790
3597250130996NonePWD SR 2023-24 Vol-6 It No-I No 6.16.5Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and NeutralNos2124.892124.891.0FalseNoneNoneFalseNoneFalse2124.890
3597251130996NonePWD SR 2023-24 Vol-6 It No-I No 6.5.1Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-chargeNos2230.22230.21.0FalseNoneNoneFalseNoneFalse2230.20
3597252130996NonePWD SR 2023-24 Vol-6 It No-I No. 6.35Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35)Nos495.6495.61.0FalseNoneNoneFalseNoneFalse495.60
3597253130996NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM DiaCum299.83299.836.786FalseNoneNoneFalseNoneFalse2034.646380
3597254130996NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM DiaCum320.9320.96.786FalseNoneNoneFalseNoneFalse2177.62740
3597255130996NonePWD SR 2023-24 V-2 Page No-175 It No-17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM DiaEach1391.391391.3928.0FalseNoneNoneFalseNoneFalse38958.920
3597256130996NonePWD SR 2023-24 V-2 Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1241.471241.471.131FalseNoneNoneFalseNoneFalse1404.102570
3597257130996NonePWD SR 2023-24 V-2 Page No-175 It No-17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1469.451469.450.565FalseNoneNoneFalseNoneFalse830.239250
3597258130996NonePWD SR 2023-24 V-2 Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM DiaCum1476.881476.880.565FalseNoneNoneFalseNoneFalse834.43720
3597259130996NonePWD SR 2023-24 V-2 Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1659.021659.020.565FalseNoneNoneFalseNoneFalse937.34630
3597260130996NonePWD SR 2023-24 V-2 Page No-177 It No-17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM DiaSqm1449.631449.634.0FalseNoneNoneFalseNoneFalse5798.520
3597261130996NonePWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)ANQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.0FalseNoneNoneFalseNoneFalse486.920
3597262130996NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum117.7117.715.0FalseNoneNoneFalseNoneFalse1765.50
3597263130996NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum126.37126.3788.155FalseNoneNoneFalseNoneFalse11140.147350
3597264130996NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.7522.038FalseNoneNoneFalseNoneFalse9911.59050
3597265130996NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.42.203FalseNoneNoneFalseNoneFalse1512.13920
3597266130996NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3715.807FalseNoneNoneFalseNoneFalse117293.788590
3597267130996NonePWD SR 2023-24 V-2 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.282.0FalseNoneNoneFalseNoneFalse11988.40
3597268130996NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.5788.155FalseNoneNoneFalseNoneFalse29053.243350
3597269130996NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum536.48536.4811.18FalseNoneNoneFalseNoneFalse5997.84640
3597270130996NonePWD SR 2023-24 V-1 Page No-15 It No-2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC )Cum7850.37850.313.85FalseNoneNoneFalseNoneFalse108726.6550
3597271130996NonePWD SR 2023-24 V-1 Page No-16 It No-2.4.3Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns)Cum7850.37850.32.88FalseNoneNoneFalseNoneFalse22608.8640
3597272130996NonePWD SR 2023-24 V-1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam)Cum8028.728028.727.66FalseNoneNoneFalseNoneFalse61499.99520
3597273130996NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)t110837.22110837.222.5FalseNoneNoneFalseNoneFalse277093.050
3597274130996NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0213.85FalseNoneNoneFalseNoneFalse8698.0770
3597275130996NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%)Cum371.01371.0115.807FalseNoneNoneFalseNoneFalse5864.555070
3597276130996NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%)Cum5495.215495.212.88FalseNoneNoneFalseNoneFalse15826.20480
3597277130996NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%)Cum4014.364014.367.66FalseNoneNoneFalseNoneFalse30749.99760
3597278130996NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR)Cum8478.478478.471.24FalseNoneNoneFalseNoneFalse10513.30280
3597279130996NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR)Cum8563.268563.260.17FalseNoneNoneFalseNoneFalse1455.75420
3597280130996NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR)Cum8478.478478.470.65FalseNoneNoneFalseNoneFalse5511.00550
3597281130996NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR)Cum8563.268563.260.1FalseNoneNoneFalseNoneFalse856.3260
3597282130996NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR)Cum8478.478478.471.872FalseNoneNoneFalseNoneFalse15871.695840
3597283130996NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR)Cum8478.478478.470.445FalseNoneNoneFalseNoneFalse3772.919150
3597284130996NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR)Cum8563.268563.260.06FalseNoneNoneFalseNoneFalse513.79560
3597285130996NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR)Cum8478.478478.4711.811FalseNoneNoneFalseNoneFalse100139.209170
3597286130996NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR)Cum8563.268563.261.196FalseNoneNoneFalseNoneFalse10241.658960
3597287130996NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR)Cum8478.478478.477.65FalseNoneNoneFalseNoneFalse64860.29550
3597288130996NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR)Cum8563.268563.261.45FalseNoneNoneFalseNoneFalse12416.7270
3597289130996NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR)Cum8478.478478.474.13FalseNoneNoneFalseNoneFalse35016.08110
3597290130996NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR)Cum8563.268563.262.42FalseNoneNoneFalseNoneFalse20723.08920
3597291130996NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) GROUND FLOORCum5934.935934.934.13FalseNoneNoneFalseNoneFalse24511.26090
3597292130996NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOORCum5994.285994.282.42FalseNoneNoneFalseNoneFalse14506.15760
3597293130996NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOORCum5087.085087.088.89FalseNoneNoneFalseNoneFalse45224.14120
3597294130996NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOORCum5137.955137.951.62FalseNoneNoneFalseNoneFalse8323.4790
3597295130996NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) GROUND FLOORCum4239.234239.2311.811FalseNoneNoneFalseNoneFalse50069.545530
3597296130996NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) TERRACE FLOORCum4281.634281.631.196FalseNoneNoneFalseNoneFalse5120.829480
3597297130996NonePWD SR 2023-24 V- 1 Page No-112 It No-16Form Work and Centering ( % On Finished Rate of Concrete per cum) Staircase and other similar structures(50%) GROUND FLOORCum4239.234239.231.872FalseNoneNoneFalseNoneFalse7935.838560
3597298130996NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )GROUND FLOORCum3815.313815.311.09FalseNoneNoneFalseNoneFalse4158.68790
3597299130996NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )TERRACE FLOORCum3853.463853.460.16FalseNoneNoneFalseNoneFalse616.55360
3597300130996NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOORt110837.22110837.223.06FalseNoneNoneFalseNoneFalse339161.89320
3597301130996NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOORt111945.59111945.590.75FalseNoneNoneFalseNoneFalse83959.19250
3597302130996NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOORCum9873.599873.5926.03FalseNoneNoneFalseNoneFalse257009.54770
3597303130996NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOORCum9972.329972.3212.79FalseNoneNoneFalseNoneFalse127545.97280
3597304130996NonePWD SR 2023-24 V-2 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.349.147FalseNoneNoneFalseNoneFalse12013.120980
3597305130996NonePWD SR 2023-24 V-2 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.143FalseNoneNoneFalseNoneFalse17507.744540
3597306130996NonePWD SR 2023-24 V-2 Page No-105 It No-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm4115.954115.958.82FalseNoneNoneFalseNoneFalse36302.6790
3597307130996NonePWD SR 2023-24 V-2 Page No-103 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3597308130996NonePWD SR 2023-24 V-2 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos148.68148.685.0FalseNoneNoneFalseNoneFalse743.40
3597309130996NonePWD SR 2023-24 V-2 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1380.241380.245.0FalseNoneNoneFalseNoneFalse6901.20
3597310130996NonePWD SR 2023-24 V-2 Page No-105 It No-12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.421303.424.0FalseNoneNoneFalseNoneFalse5213.680
3597311130996NonePWD SR 2023-24 V-2 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3597312130996NonePWD SR 2023-24 V-2 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0710.0FalseNoneNoneFalseNoneFalse1610.70
3597313130996NonePWD SR 2023-24 V-2 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3597314130996NonePWD SR 2023-24 V-2 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):.Nos340.72340.7220.0FalseNoneNoneFalseNoneFalse6814.40
3597315130996NonePWD SR 2023-24 V-2 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmNos358.07358.074.0FalseNoneNoneFalseNoneFalse1432.280
3597316130996NonePWD SR 2023-24 V-2 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOORNos74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3597317130996NonePWD SR 2023-24 V-2 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOORm64.4264.4222.2FalseNoneNoneFalseNoneFalse1430.1240
3597318130996NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm8343.428343.4212.24FalseNoneNoneFalseNoneFalse102123.46080
3597319130996NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3597320130996NonePWD SR 2023-24 V-2 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3597321130996NonePWD SR 2023-24 V-2 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOORSqm394.0394.03.15FalseNoneNoneFalseNoneFalse1241.10
3597322130996NonePWD SR 2023-24 V-2 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOORSqm2931.472931.473.15FalseNoneNoneFalseNoneFalse9234.13050
3597323130996NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOORKg208.15208.15272.16FalseNoneNoneFalseNoneFalse56650.1040
3597324130996NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3597325130996NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm61.9561.9512.96FalseNoneNoneFalseNoneFalse802.8720
3597326130996NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3597327130996NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm206.91206.9112.96FalseNoneNoneFalseNoneFalse2681.55360
3597328130996NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3597329130996NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm65.6665.668.82FalseNoneNoneFalseNoneFalse579.12120
3597330130996NonePWD SR 2023-24 V-2 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOORSqm838.8838.88.82FalseNoneNoneFalseNoneFalse7398.2160
3597331130996NonePWD SR 2023-24 V-2 Page No-84 It No-11.26.3Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOORKg226.73226.73168.0FalseNoneNoneFalseNoneFalse38090.640
3597332130996NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm261.42261.4242.0FalseNoneNoneFalseNoneFalse10979.640
3597333130996NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm264.04264.0410.0FalseNoneNoneFalseNoneFalse2640.40
3597334130996NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm315.94315.94235.785FalseNoneNoneFalseNoneFalse74493.91290
3597335130996NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm319.1319.160.6FalseNoneNoneFalseNoneFalse19337.460
3597336130996NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm453.47453.47120.42FalseNoneNoneFalseNoneFalse54606.85740
3597337130996NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm458.0458.056.1FalseNoneNoneFalseNoneFalse25693.80
3597338130996NonePWD SR 2023-24 V-2 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm365.5365.540.8FalseNoneNoneFalseNoneFalse14912.40
3597339130996NonePWD SR 2023-24 V-2 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOORSqm1795.311795.3140.8FalseNoneNoneFalseNoneFalse73248.6480
3597340130996NonePWD SR 2023-24 V-2 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOORSqm1418.651418.6579.55FalseNoneNoneFalseNoneFalse112853.60750
3597341130996NonePWD SR 2023-24 V-2 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR .Sqm1101.471101.476.87FalseNoneNoneFalseNoneFalse7567.09890
3597342130996NonePWD SR 2023-24 V-2 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR .Sqm6601.396601.3916.44FalseNoneNoneFalseNoneFalse108526.85160
3597343130996NonePWD SR 2023-24 V-2 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR)Sqm4877.944877.946.0FalseNoneNoneFalseNoneFalse29267.640
3597344130996NonePWD SR 2023-24 V-2 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3597345130996NonePWD SR 2023-24 V-2 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOORm732.24732.247.2FalseNoneNoneFalseNoneFalse5272.1280
3597346130996NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOORSqm2118.692118.696.87FalseNoneNoneFalseNoneFalse14555.40030
3597347130996NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOORSqm123.9123.9277.785FalseNoneNoneFalseNoneFalse34417.56150
3597348130996NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOORSqm125.13125.1370.6FalseNoneNoneFalseNoneFalse8834.1780
3597349130996NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOORSqm65.6665.66277.785FalseNoneNoneFalseNoneFalse18239.36310
3597350130996NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOORSqm66.3266.3270.6FalseNoneNoneFalseNoneFalse4682.1920
3597351130996NonePWD SR 2023-24 V-2 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOORSqm136.29136.29277.785FalseNoneNoneFalseNoneFalse37859.317650
3597352130996NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOORSqm137.65137.6570.6FalseNoneNoneFalseNoneFalse9718.090
3597353130996NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58120.42FalseNoneNoneFalseNoneFalse25960.14360
3597354130996NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm217.74217.7456.1FalseNoneNoneFalseNoneFalse12215.2140
3597355130996NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOORSqm774.67774.6782.0FalseNoneNoneFalseNoneFalse63522.940
3597356130996NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77318.0FalseNoneNoneFalseNoneFalse26002.860
3597357130996NonePWD SR 2023-24 V11 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Meshm42.1242.12318.0FalseNoneNoneFalseNoneFalse13394.160
3597358130996NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR)Sqm5255.835255.832.52FalseNoneNoneFalseNoneFalse13244.69160
3597359130996NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR)Sqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3597360130996NonePWDSR V-2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)m9.919.9136.0FalseNoneNoneFalseNoneFalse356.760
3597361130996NonePWDV2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)m10.0110.0132.94FalseNoneNoneFalseNoneFalse329.72940
3597362130996NoneOLD SR 18-19 It No-4.55Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication chargesSqm729.24729.2411.07FalseNoneNoneFalseNoneFalse8072.68680
3597363130996NonePWD SR 2023-24 V-2 Page No-131 It No-14.3.1NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach7405.57405.51.0FalseNoneNoneFalseNoneFalse7405.50
3597364130996NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2183.02183.01.0FalseNoneNoneFalseNoneFalse2183.00
3597365130996NonePWD SR 2023-24 V-2 Page No-136 It No-14.34.1Providing and fixing toilet paper holder :C.P. brassEach753.31753.311.0FalseNoneNoneFalseNoneFalse753.310
3597366130996NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNos.377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3597367130996NonePWD SR 2023-24 V-2 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach3173.073173.072.0FalseNoneNoneFalseNoneFalse6346.140
3597368130996NonePWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mmNos.5986.845986.841.0FalseNoneNoneFalseNoneFalse5986.840
3597369130996NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class EconomyNos.2388.792388.791.0FalseNoneNoneFalseNoneFalse2388.790
3597370130996NonePWD SR 2023-24 V-2 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each614.54614.543.0FalseNoneNoneFalseNoneFalse1843.620
3597371130996NonePWD SR 2023-24 V-2 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lidNos.250.27250.275.0FalseNoneNoneFalseNoneFalse1251.350
3597372130996NonePWD SR 2023-24 V-2 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Nos.1003.591003.593.0FalseNoneNoneFalseNoneFalse3010.770
3597373130996NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mmEach1261.31261.32.0FalseNoneNoneFalseNoneFalse2522.60
3597374130996NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap.Each58.2358.234.0FalseNoneNoneFalseNoneFalse232.920
3597375130996NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste linesm113.98113.986.0FalseNoneNoneFalseNoneFalse683.880
3597376130996NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0712.0FalseNoneNoneFalseNoneFalse4296.840
3597377130996NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.01477.016.0FalseNoneNoneFalseNoneFalse2862.060
3597378130996NoneLQ RateAir Vent Cowel -75 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3597379130996NoneLQ RateAir Vent Cowel -110 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3597380130996NonePWD SR 2023-24 V-2 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter.m360.54360.544.0FalseNoneNoneFalseNoneFalse1442.160
3597381130996NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipesm469.58469.5825.0FalseNoneNoneFalseNoneFalse11739.50
3597382130996NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipesm591.0591.010.0FalseNoneNoneFalseNoneFalse5910.00
3597383130996NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipesm690.12690.123.0FalseNoneNoneFalseNoneFalse2070.360
3597384130996NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipesm591.0591.011.0FalseNoneNoneFalseNoneFalse6501.00
3597385130996NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipesm902.25902.2532.0FalseNoneNoneFalseNoneFalse28872.00
3597386130996NonePWD SR 2023-24 V-2 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos.1511.581511.581.0FalseNoneNoneFalseNoneFalse1511.580
3597387130996NonePWD SR 2023-24 V-2 Page No-118 It No-13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameterNos.345.68345.681.0FalseNoneNoneFalseNoneFalse345.680
3597388130996NonePWD SR 2023-24 V-2 Page No-135 It No-14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Nos.6891.316891.311.0FalseNoneNoneFalseNoneFalse6891.310
3597389130996NonePWD SR 2023-24 V-2 Page No-119 It No-13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Nos.768.18768.181.0FalseNoneNoneFalseNoneFalse768.180
3597390130996NonePWD SR 2023-24 V-2 Page No-119 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr11.2611.261000.0FalseNoneNoneFalseNoneFalse11260.00
3597391130996NonePWD SR 2023-24 V-2 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g.Nos.123.9123.95.0FalseNoneNoneFalseNoneFalse619.50
3597392130996NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3597393130996NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore HorizontalNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3597394130996NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valvesNos.1877.081877.0810.0FalseNoneNoneFalseNoneFalse18770.80
3597395130996NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valvesNos.2112.342112.341.0FalseNoneNoneFalseNoneFalse2112.340
3597396130996NonePWD SR 2023-24 V-2 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia.Nos.1957.621957.621.0FalseNoneNoneFalseNoneFalse1957.620
3597397130996NonePWD SR 2023-24 V-2 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.Nos.387.8387.810.0FalseNoneNoneFalseNoneFalse3878.00
3597398130996NonePWD SR Old Sr 2018- 19 It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4Nos.18749.7818749.782.0FalseNoneNoneFalseNoneFalse37499.560
3597399130996NonePWD SR 2023-24 V-2 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Nos.6990.436990.432.0FalseNoneNoneFalseNoneFalse13980.860
3597400130996NonePWD SR 2023-24 V-2 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.Nos.3197.853197.854.0FalseNoneNoneFalseNoneFalse12791.40
3597401130996NonePWD SR 2023-24 Volume 6 It No-2.2.1NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.423.0FalseNoneNoneFalseNoneFalse952.260
3597402130996NonePWD SR 2023-24 Volume 6 It No-2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2213.0FalseNoneNoneFalseNoneFalse5813.860
3597403130996NonePWD SR 2023-24 Volume 6 It No-2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.92.0FalseNoneNoneFalseNoneFalse1309.80
3597404130996NonePWD SR 2023-24 Volume 6 It No-2.2.4POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.861.0FalseNoneNoneFalseNoneFalse798.860
3597405130996NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 WayEach121.54121.541.0FalseNoneNoneFalseNoneFalse121.540
3597406130996NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 WayEach146.32146.321.0FalseNoneNoneFalseNoneFalse146.320
3597407130996NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5WayEach161.66161.661.0FalseNoneNoneFalseNoneFalse161.660
3597408130996NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 WayEach204.14204.141.0FalseNoneNoneFalseNoneFalse204.140
3597409130996NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 WayEach258.42258.421.0FalseNoneNoneFalseNoneFalse258.420
3597410130996NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 WayEach162.84162.844.0FalseNoneNoneFalseNoneFalse651.360
3597411130996NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 WayEach187.62187.6210.0FalseNoneNoneFalseNoneFalse1876.20
3597412130996NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5WayEach208.86208.864.0FalseNoneNoneFalseNoneFalse835.440
3597413130996NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 WayEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3597414130996NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 WayEach307.98307.982.0FalseNoneNoneFalseNoneFalse615.960
3597415130996NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 WayEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3597416130996NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 ModuleEach161.66161.665.0FalseNoneNoneFalseNoneFalse808.30
3597417130996NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 ModuleEach189.98189.9811.0FalseNoneNoneFalseNoneFalse2089.780
3597418130996NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 ModuleEach206.5206.55.0FalseNoneNoneFalseNoneFalse1032.50
3597419130996NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 ModuleEach276.12276.126.0FalseNoneNoneFalseNoneFalse1656.720
3597420130996NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 ModuleEach335.12335.123.0FalseNoneNoneFalseNoneFalse1005.360
3597421130996NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12ModuleEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3597422130996NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switchEach120.36120.3636.0FalseNoneNoneFalseNoneFalse4332.960
3597423130996NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switchEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3597424130996NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way socketsEach201.78201.7814.0FalseNoneNoneFalseNoneFalse2824.920
3597425130996NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator'sEach421.26421.263.0FalseNoneNoneFalseNoneFalse1263.780
3597426130996NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.485.0FalseNoneNoneFalseNoneFalse1392.40
3597427130996NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.45.0FalseNoneNoneFalseNoneFalse1062.00
3597428130996NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.681.0FalseNoneNoneFalseNoneFalse384.680
3597429130996NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.861.0FalseNoneNoneFalseNoneFalse208.860
3597430130996NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Ding Donng bellEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3597431130996NonePWD SR 2023-24 Volume 6 It No-13.12Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.463.0FalseNoneNoneFalseNoneFalse697.380
3597432130996NonePWD SR 2023-24 Volume 6 It No-1.13Supply and fixing one metal Fan box with round hookEach138.06138.063.0FalseNoneNoneFalseNoneFalse414.180
3597433130996NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.88145.0FalseNoneNoneFalseNoneFalse11292.60
3597434130996NonePWD SR 2023-24 Volume 6 It No-1.2.2Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thickm92.0492.04185.0FalseNoneNoneFalseNoneFalse17027.40
3597435130996NonePWD SR 2023-24 Volume 6 It No-1.2.3Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3597436130996NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.2430.0FalseNoneNoneFalseNoneFalse2407.20
3597437130996NonePWD SR 2023-24 Volume 6 It No-1.3.2Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.2235.0FalseNoneNoneFalseNoneFalse3262.70
3597438130996NonePWD SR 2023-24 Volume 6 It No-1.3.3Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.825.0FalseNoneNoneFalseNoneFalse584.10
3597439130996NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.8215.0FalseNoneNoneFalseNoneFalse867.30
3597440130996NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25mm deep junction boxEach66.0866.0820.0FalseNoneNoneFalseNoneFalse1321.60
3597441130996NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction boxEach71.9871.982.0FalseNoneNoneFalseNoneFalse143.960
3597442130996NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mmm30.6830.68265.0FalseNoneNoneFalseNoneFalse8130.20
3597443130996NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.56320.0FalseNoneNoneFalseNoneFalse15859.20
3597444130996NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm74.3474.34220.0FalseNoneNoneFalseNoneFalse16354.80
3597445130996NonePWD SR 2023-24 Volume 6 It No-2.3.5WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.5660.0FalseNoneNoneFalseNoneFalse6513.60
3597446130996NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.5440.0FalseNoneNoneFalseNoneFalse141.60
3597447130996NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.7260.0FalseNoneNoneFalseNoneFalse283.20
3597448130996NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2616.0FalseNoneNoneFalseNoneFalse132.160
3597449130996NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.264.0FalseNoneNoneFalseNoneFalse33.040
3597450130996NonePWD SR 2023-24 Volume 6 It No-5.19.6MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & NEach1798.321798.321.0FalseNoneNoneFalseNoneFalse1798.320
3597451130996NonePWD SR 2023-24 Volume 6 It No-5.19.9MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.221.0FalseNoneNoneFalseNoneFalse2748.220
3597452130996NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3597453130996NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.82.0FalseNoneNoneFalseNoneFalse2501.60
3597454130996NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3597455130996NonePWD SR 2023-24 Volume 6 It No-12.3.2ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 WEach814.2814.24.0FalseNoneNoneFalseNoneFalse3256.80
3597456130996NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.328.0FalseNoneNoneFalseNoneFalse12498.560
3597457130996NoneMR 5Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.09.0FalseNoneNoneFalseNoneFalse4779.00
3597458130996NoneMR 6Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.03.0FalseNoneNoneFalseNoneFalse5841.00
3597459130996NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.561.0FalseNoneNoneFalseNoneFalse1760.560
3597460130996NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm)Each3158.863158.863.0FalseNoneNoneFalseNoneFalse9476.580
3597461130996NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.9612.0FalseNoneNoneFalseNoneFalse1727.520
3597462130996NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.783.0FalseNoneNoneFalseNoneFalse605.340
3597463130996NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.561.0FalseNoneNoneFalseNoneFalse580.560
3597464130996NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.82.0FalseNoneNoneFalseNoneFalse8283.60
3597465130996NonePWD SR 2023-24 Volume 6 It No-12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI stripm96.7696.7630.0FalseNoneNoneFalseNoneFalse2902.80
3597466130996NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.52.0FalseNoneNoneFalseNoneFalse2065.00
3597467130996NoneMR 7Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem28.3228.3280.0FalseNoneNoneFalseNoneFalse2265.60
3597468130996Nonedata ratePreparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Job260945.0260945.01.0FalseNoneNoneFalseNoneFalse260945.00
17218072430000NoneNoneBuildingsConstruction of primary health centre at Chilakanahatti in hospet taluk in vijayanagar district .35053667.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3597469130997NonePWD SR 2023-24 V- III Page No-9 It No-2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.9215.91FalseNoneNoneFalseNoneFalse7746.89720
3597470130997NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth.Cum117.7117.7477.3FalseNoneNoneFalseNoneFalse56178.210
3597471130997NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m.Cum126.37126.37454.299FalseNoneNoneFalseNoneFalse57409.764630
3597472130997NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work in surface excavation by mechanical means for lowering & levelling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.75190.024FalseNoneNoneFalseNoneFalse85463.2940
3597473130997NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.412.886FalseNoneNoneFalseNoneFalse8844.95040
3597474130997NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.Cum7017.697017.69126.605FalseNoneNoneFalseNoneFalse888474.642450
3597475130997NonePWD SR 2023-24 V-1I Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.2891.0FalseNoneNoneFalseNoneFalse130264.20
3597476130997NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.57454.299FalseNoneNoneFalseNoneFalse149723.321430
3597477130997NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum536.48536.48281.749FalseNoneNoneFalseNoneFalse151152.703520
3597478130997NonePWD SR 2023-24 V-I Page No-15 It No-2.2.3Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine ggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7850.37850.376.112FalseNoneNoneFalseNoneFalse597502.03360
3597479130997NonePWD SR 2023-24 V-I Page No-16 It No-2.4.3Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates,Cum7850.37850.319.152FalseNoneNoneFalseNoneFalse150348.94560
3597480130997NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7239.53FalseNoneNoneFalseNoneFalse317375.30160
3597481130997NonePWD SR 2023-24 V-I Page No-16 It No-2.3.2Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7220.7FalseNoneNoneFalseNoneFalse166194.5040
3597482130997NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.2213.44FalseNoneNoneFalseNoneFalse1489652.23680
3597483130997NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0276.112FalseNoneNoneFalseNoneFalse47799.858240
3597484130997NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Foundation, Sub structure of Cross drainages (5%)Cum350.88350.88126.605FalseNoneNoneFalseNoneFalse44423.16240
3597485130997NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)RCC Columns / Shaft (Slip Centering) ( 70% )Cum5495.215495.2120.08FalseNoneNoneFalseNoneFalse110343.81680
3597486130997NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum) Plinth Beams of Buildings (50%)Cum4014.364014.3639.53FalseNoneNoneFalseNoneFalse158687.65080
3597487130997NonePWD SR 2023-24 V-1 Page No-112 It No-11Foundation upto PlinthForm Work and Centering (Addendum - Vol-1, Page No -111) ( % On Finished Rate of Concrete per Cum)Earth retaining structures ( 10% )Cum802.87802.8720.7FalseNoneNoneFalseNoneFalse16619.4090
3597488130997NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2ABOVE PLINTH Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels GROUND FLOOR .Cum8478.478478.475.5FalseNoneNoneFalseNoneFalse46631.5850
3597489130997NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Lintels TERRACE FLOORCum8563.268563.260.132FalseNoneNoneFalseNoneFalse1130.350320
3597490130997NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill -GROUND FLOORCum8478.478478.470.715FalseNoneNoneFalseNoneFalse6062.106050
3597491130997NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. RCC Sill - TERRACE FLOORCum8563.268563.260.022FalseNoneNoneFalseNoneFalse188.391720
3597492130997NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. R.C.C Staircase GROUND FLOORCum8478.478478.473.395FalseNoneNoneFalseNoneFalse28784.405650
3597493130997NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB GROUND FLOORCum8478.478478.4784.53FalseNoneNoneFalseNoneFalse716685.06910
3597494130997NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF SLAB - TERRACE FLOORCum8563.268563.262.7FalseNoneNoneFalseNoneFalse23120.8020
3597495130997NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM GROUND FLOORCum8478.478478.4742.11FalseNoneNoneFalseNoneFalse357028.37170
3597496130997NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ROOF BEAM TERRACE FLOORCum8563.268563.261.66FalseNoneNoneFalseNoneFalse14215.01160
3597497130997NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. GROUND FLOOR R.C.C ColumnCum8478.478478.4725.17FalseNoneNoneFalseNoneFalse213403.08990
3597498130997NonePWD SR 2023-24 V- I Page No-16 It No-2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. TERRACE FLOOR, R.C.C ColumnCum8563.268563.268.86FalseNoneNoneFalseNoneFalse75870.48360
3597499130997NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty GROUND FLOORCum5934.935934.9325.17FalseNoneNoneFalseNoneFalse149382.18810
3597500130997NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Columns / Shaft (Slip Centering) ( 70% ) Columns Qty TERRACE FLOORCum5994.285994.288.86FalseNoneNoneFalseNoneFalse53109.32080
3597501130997NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM GROUND FLOORCum5087.085087.0842.11FalseNoneNoneFalseNoneFalse214216.93880
3597502130997NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Beams, Lintels & Troughs of Aqueducts (60%) BEAM TERRACE FLOORCum5137.955137.951.66FalseNoneNoneFalseNoneFalse8528.9970
3597503130997NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL GROUND FLOORCum5087.085087.085.5FalseNoneNoneFalseNoneFalse27978.940
3597504130997NonePWD SR 2023-24 V-1 Page No-112 It No-14Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) LINTEL TERRACE FLOORCum5137.955137.950.132FalseNoneNoneFalseNoneFalse678.20940
3597505130997NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof Slab GROUND FLOORCum4239.234239.2384.53FalseNoneNoneFalseNoneFalse358342.11190
3597506130997NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) RCC Roof Slabs (50%) Roof SlabTERRACE FLOORCum4281.634281.632.7FalseNoneNoneFalseNoneFalse11560.4010
3597507130997NonePWD SR 2023-24 V-1 Page No-112 It No-16Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Staircase and other similar structures (50%) Staircase GROUND FLOORCum4239.234239.233.395FalseNoneNoneFalseNoneFalse14392.185850
3597508130997NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills GROUND FLOORCum3815.313815.310.715FalseNoneNoneFalseNoneFalse2727.946650
3597509130997NonePWD SR 2023-24 V1 Page No-112 It No-19Form Work and Centering (Apendix - Vol-1, Page No -111) (% On Finished Rate of Concrete per Cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Sills TERRACE FLOORCum3853.463853.460.022FalseNoneNoneFalseNoneFalse84.776120
3597510130997NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) GROUND FLOORt110837.22110837.2221.12FalseNoneNoneFalseNoneFalse2340882.08640
3597511130997NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) TERRACE FLOORt111945.59111945.592.3FalseNoneNoneFalseNoneFalse257474.8570
3597512130997NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORCum9873.599873.59247.82FalseNoneNoneFalseNoneFalse2446873.07380
3597513130997NonePWD SR 2023-24 V11 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. TERRACE FLOORCum9972.329972.3246.69FalseNoneNoneFalseNoneFalse465607.62080
3597514130997NonePWD SR 2023-24 V11 Page No-17 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOORSqm1313.341313.34118.68FalseNoneNoneFalseNoneFalse155867.19120
3597515130997NonePWD SR 2023-24 V11 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.168FalseNoneNoneFalseNoneFalse20568.539040
3597516130997NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification -do- 40 mm thick both side Teak GROUND FLOORSqm6145.446145.448.64FalseNoneNoneFalseNoneFalse53096.60160
3597517130997NonePWD SR 2023-24 V11 Page No-104 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOREach1258.821258.8212.0FalseNoneNoneFalseNoneFalse15105.840
3597518130997NonePWD SR 2023-24 V11 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. Complete. GROUND FLOOREach148.68148.684.0FalseNoneNoneFalseNoneFalse594.720
3597519130997NonePWD SR 2023-24 V11 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. Complete. GROUND FLOOREach1380.241380.244.0FalseNoneNoneFalseNoneFalse5520.960
3597520130997NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. Complete. GROUND FLOOREach1303.421303.422.0FalseNoneNoneFalseNoneFalse2606.840
3597521130997NonePWD SR 2023-24 V11 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. Complete. GROUND FLOOREach293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3597522130997NonePWD SR 2023-24 V11 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. Complete. GROUND FLOOREach161.07161.078.0FalseNoneNoneFalseNoneFalse1288.560
3597523130997NonePWD SR 2023-24 V11 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOREach68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3597524130997NonePWD SR 2023-24 V11 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. Complete : 125x85x5.5 mm (heavy type) GROUND FLOOREach340.72340.7216.0FalseNoneNoneFalseNoneFalse5451.520
3597525130997NonePWD SR 2023-24 V11 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. Complete : 150x10mm GROUND FLOOREach358.07358.072.0FalseNoneNoneFalseNoneFalse716.140
3597526130997NonePWD SR 2023-24 V11 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOREach74.3474.348.0FalseNoneNoneFalseNoneFalse594.720
3597527130997NonePWD SR 2023-24 V11 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOORm64.4264.4216.8FalseNoneNoneFalseNoneFalse1082.2560
3597528130997NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm8343.428343.4248.6FalseNoneNoneFalseNoneFalse405490.2120
3597529130997NonePWD SR 2023-24 V11 Page No-105 It No-12.57.7Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Co-extruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3597530130997NonePWD SR 2023-24 V11 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7085.847085.842.88FalseNoneNoneFalseNoneFalse20407.21920
3597531130997NonePWD SR 2023-24 V11 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 no's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GROUND FLOORSqm394.0394.020.475FalseNoneNoneFalseNoneFalse8067.150
3597532130997NonePWD SR 2023-24 V11 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelam GROUND FLOORSqm2931.472931.4720.475FalseNoneNoneFalseNoneFalse60021.848250
3597533130997NonePWD SR 2023-24 V-2 Page No-111 It No-12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Co extruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -1900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOORSqm7737.557737.5540.95FalseNoneNoneFalseNoneFalse316852.67250
3597534130997NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOORKg208.15208.151081.08FalseNoneNoneFalseNoneFalse225026.8020
3597535130997NonePWD SR 2023-24 V11 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3597536130997NonePWD SR 2023-24 V-2 Page No-87 It No-11.35.1.3Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOORKg618.26618.2637.8FalseNoneNoneFalseNoneFalse23370.2280
3597537130997NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm61.9561.9551.48FalseNoneNoneFalseNoneFalse3189.1860
3597538130997NonePWD SR 2023-24 V11 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3597539130997NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm206.91206.9151.48FalseNoneNoneFalseNoneFalse10651.72680
3597540130997NonePWD SR 2023-24 V11 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3597541130997NonePWD SR 2023-24 V11 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm65.6665.668.64FalseNoneNoneFalseNoneFalse567.30240
3597542130997NonePWD SR 2023-24 V11 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) GROUND FLOORSqm734.72734.728.64FalseNoneNoneFalseNoneFalse6347.98080
3597543130997NonePWD SR 2023-24 V11 Page No-85 It No-11.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOORKg700.03700.03372.6FalseNoneNoneFalseNoneFalse260831.1780
3597544130997NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering GROUND FLOORSqm261.42261.42155.7FalseNoneNoneFalseNoneFalse40703.0940
3597545130997NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling plastering TERRACE FLOORSqm264.04264.0418.0FalseNoneNoneFalseNoneFalse4752.720
3597546130997NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm315.94315.941940.212FalseNoneNoneFalseNoneFalse612990.579280
3597547130997NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm319.1319.1210.255FalseNoneNoneFalseNoneFalse67092.37050
3597548130997NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm453.47453.47491.752FalseNoneNoneFalseNoneFalse222994.779440
3597549130997NonePWD SR 2023-24 V11 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm458.0458.0212.955FalseNoneNoneFalseNoneFalse97533.390
3597550130997NonePWD SR 2023-24 V11 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORSqm365.5365.5341.085FalseNoneNoneFalseNoneFalse124666.56750
3597551130997NonePWD SR 2023-24 V11 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOORSqm1795.311795.31341.085FalseNoneNoneFalseNoneFalse612353.311350
3597552130997NonePWD SR 2023-24 V11 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GROUND FLOORSqm1418.651418.65472.6FalseNoneNoneFalseNoneFalse670453.990
3597553130997NonePWD SR 2023-24 V11 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOORSqm1101.471101.4748.2FalseNoneNoneFalseNoneFalse53090.8540
3597554130997NonePWD SR 2023-24 V11 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm6601.396601.3926.45FalseNoneNoneFalseNoneFalse174606.76550
3597555130997NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOORSqm4877.944877.9413.0FalseNoneNoneFalseNoneFalse63413.220
3597556130997NonePWD SR 2023-24 V11 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, pre-moulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 TERRACE FLOORSqm4926.724926.721.0FalseNoneNoneFalseNoneFalse4926.720
3597557130997NonePWD SR 2023-24 V11 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3597558130997NonePWD SR 2023-24 V11 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. Complete. GROUND FLOORm732.24732.242.4FalseNoneNoneFalseNoneFalse1757.3760
3597559130997NonePWD SR 2023-24 V11 Page No-64 It No-9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOORSqm5335.135335.1330.0FalseNoneNoneFalseNoneFalse160053.90
3597560130997NonePWD SR 2023-24 V-2 Page No-65 It No-9.4Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, grinding the edge to half/full round wherever required, labour, curing complete as per specification. GROUND FLOORSqm1154.741154.7418.5FalseNoneNoneFalseNoneFalse21362.690
3597561130997NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece. GROUND FLOORSqm2118.692118.69411.1FalseNoneNoneFalseNoneFalse870993.4590
3597562130997NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GROUND FLOORSqm2118.692118.6948.2FalseNoneNoneFalseNoneFalse102120.8580
3597563130997NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge GROUND FLOORSqm123.9123.91940.212FalseNoneNoneFalseNoneFalse240392.26680
3597564130997NonePWD SR 2023-24 V11 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in in-charge TERRACE FLOORSqm125.13125.13210.255FalseNoneNoneFalseNoneFalse26309.208150
3597565130997NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm65.6665.662095.912FalseNoneNoneFalseNoneFalse137617.581920
3597566130997NonePWD SR 2023-24 V11 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm66.3266.32228.255FalseNoneNoneFalseNoneFalse15137.87160
3597567130997NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. GROUND FLOORSqm136.29136.292095.912FalseNoneNoneFalseNoneFalse285651.846480
3597568130997NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. TERRACE FLOORSqm137.65137.65228.255FalseNoneNoneFalseNoneFalse31419.300750
3597569130997NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58491.752FalseNoneNoneFalseNoneFalse106011.896160
3597570130997NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORSqm217.74217.74212.955FalseNoneNoneFalseNoneFalse46368.82170
3597571130997NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealant like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution. TERRACE FLOORSqm767.0767.0540.0FalseNoneNoneFalseNoneFalse414180.00
3597572130997NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77876.0FalseNoneNoneFalseNoneFalse71630.520
3597573130997NonePWD SR 2023-24 V-2 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanized iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment )m42.1242.121278.0FalseNoneNoneFalseNoneFalse53829.360
3597574130997NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. TERRACE FLOORSqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3597575130997NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOORm9.919.91148.8FalseNoneNoneFalseNoneFalse1474.6080
3597576130997NonePWD SR V11 Page No-44 It No-8.16.4( SR 2021-22)Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOORm10.0110.014.8FalseNoneNoneFalseNoneFalse48.0480
3597577130997NoneApproved Rate 1Providing & Fixing of Anti Microbial Bio-Safe Coated Integral Densified Tegular/Butt edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System without perforation Plain/Designer ceiling Tiles in Module Size of 600x600x15mm with Exposed T24 mm Grid for Hospitals, Institutions, Laboratories, Health Care Units, Offices. The Anti Microbial Bio-Safe lightweight calcium Silicate ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingredients. The Tiles should have Anti Microbial Bio-Safe Coating on front and back sides of tiles confirming to JIS-Z2801 and ASTM G-21 standard by NABL accredited Labs and found to be completely protected from Bacteria, Fungi, Yeast and Mould when exposed to these organisms both room temperature and AC temperature. Tiles should be protected and is free from colony forming units. The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performance A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC(Noise Reduction Coefficient ) 0.1 to 0.15 (Plain and Designer tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB, Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350 kg/m3 density in the center portion of the body, Light Reflectance 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with Inorganic Recycled content of 46- 50% out of which 18-20% should be FLY ASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system.Sqm2522.62522.655.0FalseNoneNoneFalseNoneFalse138743.00
3597578130997NoneApproved Rate 2Anti bacterial, hygienic, dust free, washable Poly Urethane Wall Coating : Providing and applying 2 coats of PU based, single component R 12 CP over the finished and levelled surface of white cement based putty finished with Cement primer, using slow speed heavy duty drilling machine fixed with mixing paddle, applying first coat using brush or roller @ 9 to 10 Sq.mt/Liter/coat (50 microns DFT in one coat) and allowing to dry for two to three hours, applying second coat and allowing to dry completely, etc as per manufacturer's specification.Sqm967.6967.652.0FalseNoneNoneFalseNoneFalse50315.20
3597579130997NoneApproved Rate 3Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with anti glare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Scrub Door /Dirty utility Door (Double leaf) 1.5 mtr X 2.10 mtr Say 3.15 Sq.mtSqm53843.453843.46.3FalseNoneNoneFalseNoneFalse339213.420
3597580130997NoneApproved Rate 4Vinyl flooring: Supply & laying PVC flooring with self levelling It should be with 2mm antistatic seamless PVC flooring. The PVC flooring should meet the following specification. The floor should be smooth, non-slip, impervious material conductive enough to dissipate static electricity but not conductive enough to endanger personnel from electric shock. Electrostatic charge dissipation combat PVC seamless flooring of very high quality should be provided. Thickness not less than 2 mm. Continuous roll should be used and joints should be welded by special PVC thermal welding units using PVC welding bars of same colour. The sheets should be highly durable with resistance to shock and indentation. It should be scratch proof The conductive material should be uniformly impregnated as grains. It should be inert to body fluids, chemicals and disinfectants. Should not be affected by temperature variation within the OT. The floor should efficiently discharge electric charges up to 2 kV. Flooring should be laid by skilled workers of accredited agencies authorized by the supplier of PVC sheets. The electrical resistance (point to ground) should be within 2.5x10 4 to 5x10 6 ohms. The floor should not allow build up of electrical charge beyond 100 volts due to antistatic effect. The corners should not be terminated sharply and concealed cove- former (aluminium) should be used to overlap the wall panel to a height of approx. 25mm and sealed perfectly and uniformly. Self levelling compounds should be usedSqm3304.03304.055.0FalseNoneNoneFalseNoneFalse181720.00
3597581130997NoneApproved Rate 5Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceded accessories.Nos76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
3597582130997NoneApproved Rate 6Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel.Nos33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
3597583130997NoneApproved Rate 7Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel.Nos7080.07080.01.0FalseNoneNoneFalseNoneFalse7080.00
3597584130997NoneApproved Rate 8Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units.Nos70800.070800.02.0FalseNoneNoneFalseNoneFalse141600.00
3597585130997NoneApproved Rate 9Stainless Steel Scrub Sink with automatic and manual Foot or knee operator / sensor with 2 Boys: Compact Surgical Scrub sink should be designed for use in Operation theatre complex providing surgeons with a convenient sink for pre op scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel of 1.6mm thickness & should be seamless welded construction polished to a satin finish. The scrub sink should be provided with a front access panel, which should be easily removed for access to the water control valve, waste connections, stopper strainer. Hands free Operation should include infrared sensor and foot operator with built in range of adjustment. Thermostatic Mixing Valve control should be located behind the access panel & maintain constant water temperature The timing should be adjustable to meet individual application requirement, provided with infrared sensor thermostatic controlled taps with fail- safe temperature controls. All units should have reduced anti splash fronts It should have knee/foot operated switch.Nos287535.32287535.321.0FalseNoneNoneFalseNoneFalse287535.320
3597586130997NoneApproved Rate 10Supplying and Fixing providing and making trap door of size 600 x600mm in the ceiling panel by cutting. The required frame work shall be made by using aluminium sections. The cost includes cost of material,labour charges for fixing etc completeNos7375.07375.01.0FalseNoneNoneFalseNoneFalse7375.00
3597587130997NonePWD SR 2023-24 V2 Page No-131 It No-14.3.1WATER SUPPLY: Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet GROUND FLOOREach7405.57405.511.0FalseNoneNoneFalseNoneFalse81460.50
3597588130997NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equivalent ). Health Faucet GROUND FLOOREach2183.02183.011.0FalseNoneNoneFalseNoneFalse24013.00
3597589130997NonePWD SR 2023-24 V-2 Page No-131 It No-14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Urinal Basin GROUND FLOOREach5518.55518.53.0FalseNoneNoneFalseNoneFalse16555.50
3597590130997NonePWD SR 2023-24 V-2 Page No-123 It No-14.34.1Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder GROUND FLOOREach753.31753.3111.0FalseNoneNoneFalseNoneFalse8286.410
3597591130997NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal bore GROUND FLOOREach377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3597592130997NonePWD SR 2023-24 V-2 Page No-70 It No-10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal Partitions GROUND FLOORSqm3455.573455.572.88FalseNoneNoneFalseNoneFalse9952.04160
3597593130997NonePWD SR 2023-24 V11 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern Wash Basin GROUND FLOOREach3173.073173.075.0FalseNoneNoneFalseNoneFalse15865.350
3597594130997NoneApproved Rate Providing and fixing star white counter wash basin 405mm dia cat no: 91085 with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of counter top pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Arrived data Counter Wash Basin GROUND FLOOREach8873.68873.65.0FalseNoneNoneFalseNoneFalse44368.00
3597595130997NonePWD SR 2023-24 V-2 Page No-134 It No-14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Laboratory Sink GROUND FLOORNos.6296.596296.592.0FalseNoneNoneFalseNoneFalse12593.180
3597596130997NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Economy GROUND FLOORNos.2275.042275.042.0FalseNoneNoneFalseNoneFalse4550.080
3597597130997NonePWD SR 2023-24 V11 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail GROUND FLOOREach614.54614.5410.0FalseNoneNoneFalseNoneFalse6145.40
3597598130997NonePWD SR 2023-24 V11 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid GROUND FLOOREach250.27250.2721.0FalseNoneNoneFalseNoneFalse5255.670
3597599130997NonePWD SR 2023-24 V11 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. GROUND FLOOREach1003.591003.5912.0FalseNoneNoneFalseNoneFalse12043.080
3597600130997NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Mirror GROUND FLOOREach1261.31261.310.0FalseNoneNoneFalseNoneFalse12613.00
3597601130997NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. Iron grating for gully trap GROUND FLOOREach58.2358.2310.0FalseNoneNoneFalseNoneFalse582.30
3597602130997NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm dia pipes, From wash basin waste lines Flexible Waste Pipe GROUND FLOORm113.98113.9812.0FalseNoneNoneFalseNoneFalse1367.760
3597603130997NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes GROUND FLOORm358.07358.0737.0FalseNoneNoneFalseNoneFalse13248.590
3597604130997NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2110mm nominal dia pipes Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. GROUND FLOORm477.01477.0126.0FalseNoneNoneFalseNoneFalse12402.260
3597605130997NonePWD SR 2023-24 V11 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOORm360.54360.5420.0FalseNoneNoneFalseNoneFalse7210.80
3597606130997NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply. GROUND FLOORm469.58469.5840.0FalseNoneNoneFalseNoneFalse18783.20
3597607130997NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Cold Water Supply GROUND FLOORm591.0591.043.0FalseNoneNoneFalseNoneFalse25413.00
3597608130997NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply GROUND FLOORm690.12690.126.0FalseNoneNoneFalseNoneFalse4140.720
3597609130997NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes Cold Water Supply- Down Take GROUND FLOORm591.0591.020.0FalseNoneNoneFalseNoneFalse11820.00
3597610130997NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 40 mm nominal dia Pipes TERRACE FLOOR Cold water Supply-From Tankm902.25902.25107.0FalseNoneNoneFalseNoneFalse96540.750
3597611130997NonePWD SR 2023-24 V11 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Bevelled Edge mirror GROUND FLOORNos.1511.581511.585.0FalseNoneNoneFalseNoneFalse7557.90
3597612130997NonePWD SR 2023-24 V-2 Page No-123 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOORLtr11.2611.262000.0FalseNoneNoneFalseNoneFalse22520.00
3597613130997NonePWD SR 2023-24 V11 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. GROUND FLOORNos.123.9123.910.0FalseNoneNoneFalseNoneFalse1239.00
3597614130997NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOORNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3597615130997NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal TERRACE FLOOR FROM OHTNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3597616130997NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.1877.081877.087.0FalseNoneNoneFalseNoneFalse13139.560
3597617130997NonePWD SR 2023-24 V-5 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 40 mm dia GM (Copper alloy) Gate valves TERRACE FLOORNos.2112.342112.342.0FalseNoneNoneFalseNoneFalse4224.680
3597618130997NonePWD SR 2023-24 V-5 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. Complete a)For DI/CI puddle flanges of 80mm dia. Puddle FlangesNo.1977.191977.192.0FalseNoneNoneFalseNoneFalse3954.380
3597619130997NonePWD SR 2023-24 V11 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GROUND FLOORNos.387.8387.820.0FalseNoneNoneFalseNoneFalse7756.00
3597620130997NoneOld Sr 2018- 19 Page No- It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOORNos18746.0718746.075.0FalseNoneNoneFalseNoneFalse93730.350
3597621130997NonePWD SR 2023-24 V11 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 GROUND FLOORNos.6990.436990.4310.0FalseNoneNoneFalseNoneFalse69904.30
3597622130997NonePWD SR 2023-24 V11 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOORNos.3197.853197.8510.0FalseNoneNoneFalseNoneFalse31978.50
3597623130997NoneApproved Rate 1Supplying, installing, testing and commissioning of Domestic Water lift mono block pump of adequate HP capable of giving required discharge at suitable head to work on 3 phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts RCC footing etc., complete with head conditions.Duty :2HP @10m head (2 no. working and 1no. Standby ) (UGT -OHT) GROUND FLOORNos17700.017700.02.0FalseNoneNoneFalseNoneFalse35400.00
3597624130997NoneApproved Rate 21354 vessel Atlantic plus,multiport valve initiative sand media 50kg,carbon media 25kg,Finolex plumbing material,Pressure guage meter,Air release valve,Jiva Natural water softner of 9000l/hrNos70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3597625130997NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER HARVESTING: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mSqm299.83299.8340.5FalseNoneNoneFalseNoneFalse12143.1150
3597626130997NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum320.9320.940.5FalseNoneNoneFalseNoneFalse12996.450
3597627130997NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.4710.56FalseNoneNoneFalseNoneFalse13109.92320
3597628130997NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.4510.56FalseNoneNoneFalseNoneFalse15517.3920
3597629130997NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.8810.56FalseNoneNoneFalseNoneFalse15595.85280
3597630130997NonePWD SR 2023-24 V-1I Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as,per direction of Engineer-in-charge.Cum1659.021659.0237.114FalseNoneNoneFalseNoneFalse61572.868280
3597631130997NonePWD SR 2023-24 V-1I Page No-175 It No-17.6.3Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270,of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mmm2325.62325.66.0FalseNoneNoneFalseNoneFalse13953.60
3597632130997NonePWD SR 2023-24 V-1I Page No-176 It No-17.8Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.hr1147.311147.3132.0FalseNoneNoneFalseNoneFalse36713.920
3597633130997NonePWD SR 2023-24 V-1I Page No-176 It No-17.9.3Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm diaEach314.7314.76.0FalseNoneNoneFalseNoneFalse1888.20
3597634130997NonePWD SR 2023-24 V-1I Page No-176 It No-17.11.3Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm diaEach354.35354.356.0FalseNoneNoneFalseNoneFalse2126.10
3597635130997NoneApproved RateProviding and fixing RCC Rings of 1500 mm dia and 600mm depth all as per requirement and direction of Engineer-in-charge. RCC ringsEach1121.01121.030.0FalseNoneNoneFalseNoneFalse33630.00
3597636130997NoneData RateProviding and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. RCC Top slabSqm1796.551796.5510.621FalseNoneNoneFalseNoneFalse19081.157550
3597637130997NonePWD SR 2023-24 V- III Page No-9 It No-2.5(ii) ASEPTIC TANK: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer. In area of light jungle100 Sqm486.92486.920.168FalseNoneNoneFalseNoneFalse81.802560
3597638130997NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m.Cum126.37126.3742.072FalseNoneNoneFalseNoneFalse5316.638640
3597639130997NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.371.16FalseNoneNoneFalseNoneFalse8607.62920
3597640130997NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8028.728028.7210.609FalseNoneNoneFalseNoneFalse85176.690480
3597641130997NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.877.467FalseNoneNoneFalseNoneFalse5995.030290
3597642130997NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%)Cum4014.364014.363.142FalseNoneNoneFalseNoneFalse12613.119120
3597643130997NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings)t110837.22110837.221.77FalseNoneNoneFalseNoneFalse196181.87940
3597644130997NoneOld SR 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.4115.0FalseNoneNoneFalseNoneFalse5631.150
3597645130997NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and traffic-able granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5953.41FalseNoneNoneFalseNoneFalse40035.60190
3597646130997NonePWD SR 2023-24 V-2 Page No-42 It No-8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm432.41432.4153.41FalseNoneNoneFalseNoneFalse23095.01810
3597647130997NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanizedNo.16284.016284.03.0FalseNoneNoneFalseNoneFalse48852.00
3597648130997NonePWD SR 2023-24 V-2 Page No-176 It No-17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm1149.791149.796.37FalseNoneNoneFalseNoneFalse7324.16230
3597649130997NonePWD SR 2023-24 V-2 Page No-13 It No-6.3Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workCum10471.3210471.321.6FalseNoneNoneFalseNoneFalse16754.1120
3597650130997NonePWD SR 2023-24 V-1I Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1241.471241.475.6FalseNoneNoneFalseNoneFalse6952.2320
3597651130997NonePWD SR 2023-24 V-1I Page No-175 It No-17.2Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1469.451469.455.6FalseNoneNoneFalseNoneFalse8228.920
3597652130997NonePWD SR 2023-24 V-1I Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1476.881476.884.0FalseNoneNoneFalseNoneFalse5907.520
3597653130997NonePWD SR 2023-24 V- III Page No-7 It No-2.5(ii)ASUMP : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Mechanical Means using Dozer In area of light jungle100 Sqm486.92486.920.185FalseNoneNoneFalseNoneFalse90.08020
3597654130997NonePWD SR 2023-24 V- 1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum126.37126.3723.887FalseNoneNoneFalseNoneFalse3018.600190
3597655130997NonePWD SR 2023-24 V- 1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.385FalseNoneNoneFalseNoneFalse17697.582450
3597656130997NonePWD SR 2023-24 V- 1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum8028.728028.7210.695FalseNoneNoneFalseNoneFalse85867.16040
3597657130997NonePWD SR 2023-24 V-1 Page No-116 It No-5Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Earth retaining structuresCum802.87802.874.375FalseNoneNoneFalseNoneFalse3512.556250
3597658130997NonePWD SR 2023-24 V-1 Page No-112 It No-15Form Work and Centering (Apendix - Vol-1, Page No -115) ( % On Finished Rate of Concrete per cum) Roof Slab of Buildings (50%) RCC WALL Roof Slab Concrete QuantityCum4014.364014.366.32FalseNoneNoneFalseNoneFalse25370.75520
3597659130997NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapping/welding joints, tying with binding wire / soft annealed steel wire and other ancillary operations complete as per drawing and technical specification. (a. Buildings) wall slab slabt110837.22110837.221.09FalseNoneNoneFalseNoneFalse120812.56980
3597660130997NoneOld Sr 2018-19 It No-11.44KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6Nos375.41375.413.0FalseNoneNoneFalseNoneFalse1126.230
3597661130997NoneApproved RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized 150 mm diaNos16284.016284.01.0FalseNoneNoneFalseNoneFalse16284.00
3597662130997NonePWD SR 2023-24 V-II Page No-150 It No-15.5Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of Greater than25 MPa (as per ASTM D 412), elongation of Greater than500% (as per ASTM D 412), puncture resistance of Greater than1000N (as per ASTM E 154), peel adhesion to concrete Greater than1200N/m (as per ASTM D 903), hydrostatic head resistance Greater than70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm749.59749.5944.6FalseNoneNoneFalseNoneFalse33431.7140
3597663130997NonePWD SR 2023-24 V-2 Page No-42 It No-8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, Curing complete as per specifications and as per directions of Engineerin- Charge.Sqm400.19400.1949.1FalseNoneNoneFalseNoneFalse19649.3290
3597664130997NonePWD SR 2023-24 Volume 6 It No-2.2.1INTERNAL ELECTRIFICATION: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.4210.0FalseNoneNoneFalseNoneFalse3174.20
3597665130997NonePWD SR 2023-24 Volume 6 It No-2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2222.0FalseNoneNoneFalseNoneFalse9838.840
3597666130997NonePWD SR 2023-24 Volume 6 It No-2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.960.0FalseNoneNoneFalseNoneFalse39294.00
3597667130997NonePWD SR 2023-24 Volume 6 It No-2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.8616.0FalseNoneNoneFalseNoneFalse12781.760
3597668130997NonePWD SR 2023-24 Volume 6 It No-2.2.5Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switchesPoint1167.021167.0210.0FalseNoneNoneFalseNoneFalse11670.20
3597669130997NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1 - 2 WayEach121.54121.542.0FalseNoneNoneFalseNoneFalse243.080
3597670130997NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 WayEach146.32146.322.0FalseNoneNoneFalseNoneFalse292.640
3597671130997NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4 - 5WayEach161.66161.663.0FalseNoneNoneFalseNoneFalse484.980
3597672130997NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach204.14204.144.0FalseNoneNoneFalseNoneFalse816.560
3597673130997NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 WayEach258.42258.422.0FalseNoneNoneFalseNoneFalse516.840
3597674130997NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 1 - 2 WayEach162.84162.8418.0FalseNoneNoneFalseNoneFalse2931.120
3597675130997NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 3 WayEach187.62187.6230.0FalseNoneNoneFalseNoneFalse5628.60
3597676130997NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 4 - 5WayEach208.86208.8622.0FalseNoneNoneFalseNoneFalse4594.920
3597677130997NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 6 WayEach259.6259.638.0FalseNoneNoneFalseNoneFalse9864.80
3597678130997NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 8 WayEach307.98307.9826.0FalseNoneNoneFalseNoneFalse8007.480
3597679130997NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 10 - 12 WayEach376.42376.428.0FalseNoneNoneFalseNoneFalse3011.360
3597680130997NonePWD SR 2023-24 Volume 6 It No-3.4.7Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall 16 WayEach428.34428.346.0FalseNoneNoneFalseNoneFalse2570.040
3597681130997NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 1 to 2 ModuleEach161.66161.6620.0FalseNoneNoneFalseNoneFalse3233.20
3597682130997NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 3 ModuleEach189.98189.9832.0FalseNoneNoneFalseNoneFalse6079.360
3597683130997NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 4 ModuleEach206.5206.525.0FalseNoneNoneFalseNoneFalse5162.50
3597684130997NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 6 ModuleEach276.12276.1242.0FalseNoneNoneFalseNoneFalse11597.040
3597685130997NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 8 ModuleEach335.12335.1228.0FalseNoneNoneFalseNoneFalse9383.360
3597686130997NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box 10/12ModuleEach405.92405.928.0FalseNoneNoneFalseNoneFalse3247.360
3597687130997NonePWD SR 2023-24 Volume 6 It No-3.5.7Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box16 ModuleEach468.46468.466.0FalseNoneNoneFalseNoneFalse2810.760
3597688130997NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switchEach120.36120.36210.0FalseNoneNoneFalseNoneFalse25275.60
3597689130997NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switchEach195.88195.8810.0FalseNoneNoneFalseNoneFalse1958.80
3597690130997NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way socketsEach201.78201.78108.0FalseNoneNoneFalseNoneFalse21792.240
3597691130997NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator'sEach421.26421.2640.0FalseNoneNoneFalseNoneFalse16850.40
3597692130997NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.4838.0FalseNoneNoneFalseNoneFalse10582.240
3597693130997NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.438.0FalseNoneNoneFalseNoneFalse8071.20
3597694130997NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3597695130997NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.862.0FalseNoneNoneFalseNoneFalse417.720
3597696130997NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Donng bellEach290.28290.282.0FalseNoneNoneFalseNoneFalse580.560
3597697130997NonePWD SR 2023-24 Volume 6 It No-13.12Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.4640.0FalseNoneNoneFalseNoneFalse9298.40
3597698130997NonePWD SR 2023-24 Volume 6 It No-1.13Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Supply and fixing one metal Fan box with round hookEach138.06138.0640.0FalseNoneNoneFalseNoneFalse5522.40
3597699130997NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.881150.0FalseNoneNoneFalseNoneFalse89562.00
3597700130997NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.041350.0FalseNoneNoneFalseNoneFalse124254.00
3597701130997NonePWD SR 2023-24 Volume 6 It No-1.2.3Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thickm121.54121.54265.0FalseNoneNoneFalseNoneFalse32208.10
3597702130997NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.24210.0FalseNoneNoneFalseNoneFalse16850.40
3597703130997NonePWD SR 2023-24 Volume 6 It No-1.3.2Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.22350.0FalseNoneNoneFalseNoneFalse32627.00
3597704130997NonePWD SR 2023-24 Volume 6 It No-1.3.3Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.8240.0FalseNoneNoneFalseNoneFalse4672.80
3597705130997NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.82110.0FalseNoneNoneFalseNoneFalse6360.20
3597706130997NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25Mm deep junction boxEach66.0866.08160.0FalseNoneNoneFalseNoneFalse10572.80
3597707130997NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box . 32Mm deep junction boxEach71.9871.9820.0FalseNoneNoneFalseNoneFalse1439.60
3597708130997NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 1.5 Sq.mmm30.6830.681750.0FalseNoneNoneFalseNoneFalse53690.00
3597709130997NonePWD SR 2023-24 Volume 6 It No-2.3.3FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.562480.0FalseNoneNoneFalseNoneFalse122908.80
3597710130997NonePWD SR 2023-24 Volume 6 It No-2.3.4FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 4 sq.mmm74.3474.34950.0FalseNoneNoneFalseNoneFalse70623.00
3597711130997NonePWD SR 2023-24 Volume 6 It No-2.3.5FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.56280.0FalseNoneNoneFalseNoneFalse30396.80
3597712130997NonePWD SR 2023-24 Volume 6 It No-2.3.6FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 10sq.mmm197.06197.06160.0FalseNoneNoneFalseNoneFalse31529.60
3597713130997NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.54220.0FalseNoneNoneFalseNoneFalse778.80
3597714130997NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.72310.0FalseNoneNoneFalseNoneFalse1463.20
3597715130997NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2680.0FalseNoneNoneFalseNoneFalse660.80
3597716130997NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.2624.0FalseNoneNoneFalseNoneFalse198.240
3597717130997NoneMR 5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmmEach9.449.4418.0FalseNoneNoneFalseNoneFalse169.920
3597718130997NonePWD SR 2023-24 Volume 6 It No-5.19.11Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP & NEach4764.844764.843.0FalseNoneNoneFalseNoneFalse14294.520
3597719130997NonePWD SR 2023-24 Volume 6 It No-5.19.12Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP & NEach5829.25829.22.0FalseNoneNoneFalseNoneFalse11658.40
3597720130997NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.223.0FalseNoneNoneFalseNoneFalse8244.660
3597721130997NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6-32 A SPEach489.7489.786.0FalseNoneNoneFalseNoneFalse42114.20
3597722130997NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3597723130997NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure.50-63 A TPNEach3643.843643.846.0FalseNoneNoneFalseNoneFalse21863.040
3597724130997NonePWD SR 2023-24 Volume 6 It No-5.20.4Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.32-40Amps 2 poleEach5379.625379.623.0FalseNoneNoneFalseNoneFalse16138.860
3597725130997NonePWD SR 2023-24 Volume 6 It No-5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63Amps 4 poleEach6543.16543.12.0FalseNoneNoneFalseNoneFalse13086.20
3597726130997NonePWD SR 2023-24 Volume 6 It No-5.17.3Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 WayEach18324.2218324.221.0FalseNoneNoneFalseNoneFalse18324.220
3597727130997NonePWD SR 2023-24 Volume 6 It No-5.15.9Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 100 A 25 kAEach10014.6610014.661.0FalseNoneNoneFalseNoneFalse10014.660
3597728130997NonePWD SR 2023-24 Volume 6 It No-5.5.2Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 63AEach4953.584953.581.0FalseNoneNoneFalseNoneFalse4953.580
3597729130997NonePWD SR 2023-24 Volume 6 It No-5.5.3Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 100AEach8934.288934.282.0FalseNoneNoneFalseNoneFalse17868.560
3597730130997NoneMR 6Supply & installation of 300 mm wide & 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m548.7548.720.0FalseNoneNoneFalseNoneFalse10974.00
3597731130997NoneMR 7Supply & installation of 150 mm wide & 40mm height, 1.6 mm thick Perfforated cable trays fixed with MS supports,anchor bolt etc.,complete as required at site.m719.8719.825.0FalseNoneNoneFalseNoneFalse17995.00
3597732130997NonePWD SR 2023-24 Volume 6 It No-11.3.1TOTAL OF MCB DB Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 WEach650.18650.184.0FalseNoneNoneFalseNoneFalse2600.720
3597733130997NonePWD SR 2023-24 Volume 6 It No-11.3.2Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 WEach814.2814.250.0FalseNoneNoneFalseNoneFalse40710.00
3597734130997NonePWD SR 2023-24 Volume 6 It No-11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12WEach1044.31044.312.0FalseNoneNoneFalseNoneFalse12531.60
3597735130997NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80. Power Input: 220-240V @50/60Hz & Power factor Greater than0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.3234.0FalseNoneNoneFalseNoneFalse53118.880
3597736130997NonePWD SR 2023-24 Volume 6 It No-11.6.3Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIGreater than 70%. efficacy Greater than 100 lumen per W, 120degree beam spread, lifeGreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2'-34-36WNo5372.545372.5412.0FalseNoneNoneFalseNoneFalse64470.480
3597737130997NoneMR 8Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.012.0FalseNoneNoneFalseNoneFalse6372.00
3597738130997NoneMR 9Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.010.0FalseNoneNoneFalseNoneFalse19470.00
3597739130997NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.5610.0FalseNoneNoneFalseNoneFalse17605.60
3597740130997NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm)Each3158.863158.8640.0FalseNoneNoneFalseNoneFalse126354.40
3597741130997NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.96112.0FalseNoneNoneFalseNoneFalse16123.520
3597742130997NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.7840.0FalseNoneNoneFalseNoneFalse8071.20
3597743130997NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the snitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.5610.0FalseNoneNoneFalseNoneFalse5805.60
3597744130997NonePWD SR 2023-24 Volume 6 It No-5.42.2Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59210000.0FalseNoneNoneFalseNoneFalse123900.00
3597745130997NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 50 x 10 mm Aluminium Stripsm4053.34053.37.0FalseNoneNoneFalseNoneFalse28373.10
3597746130997NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.916.0FalseNoneNoneFalseNoneFalse5758.40
3597747130997NonePWD SR 2023-24 Volume 6 It No-5.51.3Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 200A ATSEach109922.9109922.91.0FalseNoneNoneFalseNoneFalse109922.90
3597748130997NonePWD SR 2023-24 Volume 6 It No-5.15.15Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V 250 A 35 kAEach27783.127783.11.0FalseNoneNoneFalseNoneFalse27783.10
3597749130997NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.810.0FalseNoneNoneFalseNoneFalse12508.00
3597750130997NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.8410.0FalseNoneNoneFalseNoneFalse36438.40
3597751130997NonePWD SR 2023-24 Volume 6 It No-5.15.10Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 125 A 25 kAEach12202.3812202.386.0FalseNoneNoneFalseNoneFalse73214.280
3597752130997NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP 160 A 25 kAEach15867.4615867.462.0FalseNoneNoneFalseNoneFalse31734.920
3597753130997NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3597754130997NonePWD SR 2023-24 Volume 6 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3597755130997NonePWD SR 2023-24 Volume 6 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3597756130997NonePWD SR 2023-24 Volume 6 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3597757130997NonePWD SR 2023-24 Volume 6 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3597758130997NonePWD SR 2023-24 Volume 6 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.81.0FalseNoneNoneFalseNoneFalse188.80
3597759130997NonePWD SR 2023-24 Volume 6 It No-5.29Supplying, fixing and wiring 3 Phase Digital Ammeter / VoltmeterEach1681.51681.51.0FalseNoneNoneFalseNoneFalse1681.50
3597760130997NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6860.0FalseNoneNoneFalseNoneFalse1840.80
3597761130997NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3597762130997NonePWD SR 2023-24 Volume 6 It No-2.3.7WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 16 mm2m375.24375.2455.0FalseNoneNoneFalseNoneFalse20638.20
3597763130997NonePWD SR 2023-24 Volume 6 It No-5.42.2APFCR PANEL - 60 KVAR Fabricating supplying and mounting MS crcabox made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.59115000.0FalseNoneNoneFalseNoneFalse67850.00
3597764130997NonePWD SR 2023-24 Volume 6 It No-5.39Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsEach25535.225535.21.0FalseNoneNoneFalseNoneFalse25535.20
3597765130997NonePWD SR 2023-24 Volume 6 It No-5.40.2Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on Phenolic/FRP/DMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming & outgoing cables as per IS specification with necessary bolts, nuts & washers etc complete 250 A 4 x 30 x 10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3597766130997NonePWD SR 2023-24 Volume 6 It No-5.15.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA THREE Pole IncomersEach15867.4615867.461.0FalseNoneNoneFalseNoneFalse15867.460
3597767130997NonePWD SR 2023-24 Volume 6 It No-5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TPEach946.36946.368.0FalseNoneNoneFalseNoneFalse7570.880
3597768130997NonePWD SR 2023-24 Volume 6 It No-5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red xide and then two coats of approved paint. 40 x 40 x 6 mmm359.9359.910.0FalseNoneNoneFalseNoneFalse3599.00
3597769130997NonePWD SR 2023-24 Volume 6 It No-5.4.2Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.6 to 10 kVAREach252.52252.524.0FalseNoneNoneFalseNoneFalse1010.080
3597770130997NonePWD SR 2023-24 Volume 6 It No-5.4.3Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAREach405.92405.921.0FalseNoneNoneFalseNoneFalse405.920
3597771130997NoneMR 10ILPB Type push button with Lanmp - ON/OFF(L&T Make)Each413.0413.016.0FalseNoneNoneFalseNoneFalse6608.00
3597772130997NonePWD SR 2023-24 Volume 6 It No-5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 AEach1522.21522.26.0FalseNoneNoneFalseNoneFalse9133.20
3597773130997NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3597774130997NonePWD SR 2023-24 Volume 6 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3597775130997NonePWD SR 2023-24 Volume 6 It No-5.34Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current TransformerEach663.16663.163.0FalseNoneNoneFalseNoneFalse1989.480
3597776130997NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 1.5 mm2m30.6830.6840.0FalseNoneNoneFalseNoneFalse1227.20
3597777130997NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 2.5 mm2m49.5649.5645.0FalseNoneNoneFalseNoneFalse2230.20
3597778130997NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 4 mm2m74.3474.3435.0FalseNoneNoneFalseNoneFalse2601.90
3597779130997NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRES & CABLES Wiring for lighting/power circuit using one of FRLS PVC conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Automatic APFCR with controller along with cooling Fans and Interlocking. 16 mm2m375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3597780130997NonePWD SR 2023-24 Volume 6 It No-32.05Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 16 Sqmm, 4 Core.Km167373.56167373.560.1FalseNoneNoneFalseNoneFalse16737.3560
3597781130997NonePWD SR 2023-24 Volume 6 It No-32.09Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 35 Sqmm, 3.5 Core.Km181793.16181793.160.04FalseNoneNoneFalseNoneFalse7271.72640
3597782130997NonePWD SR 2023-24 Volume 6 It No-32.14Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 95 Sqmm, 3.5 Core.Km440393.7440393.70.12FalseNoneNoneFalseNoneFalse52847.2440
3597783130997NonePWD SR 2023-24 Volume 6 It No-2.3.7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS694:2010 16 Sqmm, 1Corem375.24375.2460.0FalseNoneNoneFalseNoneFalse22514.40
3597784130997NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 SqmmKm24645.4824645.480.14FalseNoneNoneFalseNoneFalse3450.36720
3597785130997NonePWD SR 2023-24 Volume 6 It No-21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm36744.0236744.020.12FalseNoneNoneFalseNoneFalse4409.28240
3597786130997NonePWD SR 2023-24 Volume 6 It No-6.11.1Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 19/20mmEach80.2480.2410.0FalseNoneNoneFalseNoneFalse802.40
3597787130997NonePWD SR 2023-24 Volume 6 It No-6.11.2Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 25mm diaEach99.1299.128.0FalseNoneNoneFalseNoneFalse792.960
3597788130997NonePWD SR 2023-24 Volume 6 It No-6.11.3Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) (42/6.11) 32mm diaEach138.06138.068.0FalseNoneNoneFalseNoneFalse1104.480
3597789130997NonePWD SR 2023-24 Volume 6 It No-63.02Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 GmNo48.3848.3818.0FalseNoneNoneFalseNoneFalse870.840
3597790130997NonePWD SR 2023-24 Volume 6 It No-63.05Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 GmNo156.94156.9418.0FalseNoneNoneFalseNoneFalse2824.920
3597791130997NonePWD SR 2023-24 Volume 6 It No-12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound.Each5343.045343.042.0FalseNoneNoneFalseNoneFalse10686.080
3597792130997NonePWD SR 2023-24 Volume 6 It No-12.60.3Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. Copper bonded rod with backfill compound.Each10022.9210022.922.0FalseNoneNoneFalseNoneFalse20045.840
3597793130997NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.86.0FalseNoneNoneFalseNoneFalse24850.80
3597794130997NonePWD SR 2023-24 Volume 6 It No-12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each5022.085022.084.0FalseNoneNoneFalseNoneFalse20088.320
3597795130997NonePWD SR 2023-24 Volume 6 It No-12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X6mm GI stripm151.04151.04120.0FalseNoneNoneFalseNoneFalse18124.80
3597796130997NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.56.0FalseNoneNoneFalseNoneFalse6195.00
3597797130997NonePWD SR 2023-24 Volume 6 It No-12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm Copper stripm672.6672.650.0FalseNoneNoneFalseNoneFalse33630.00
3597798130997NonePWD SR 2023-24 Volume 6 It No-12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3597799130997NonePWD SR 2023-24 Volume 6 It No-6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem22.4222.42110.0FalseNoneNoneFalseNoneFalse2466.20
3597800130997NonePWD SR 2023-24 Volume 6 It No-6.18.6Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG Copper wire.m123.9123.9220.0FalseNoneNoneFalseNoneFalse27258.00
3597801130997NoneMR 11CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 4 MP IP Indoor Dome camera with 1 / 3” progressive scan CMOS Image Sensor 2.8mm Fixed Lens 2560 X 1440 @30fps resolution, IR Illumination Up to 40m IR Distance ,WDR, Video Compression H.265+/ H.264+/ H.265/ H.264/ DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vandal Resistance,The prices should include the necessary mounts and brackets.Nos.17700.017700.06.0FalseNoneNoneFalseNoneFalse106200.00
3597802130997NoneMR 12Supply, Installation, Testing & Commissioning of 5MP IP Dome /Bullet camera with 1 / 3.0” Progressive Scan CMOS Image Sensor F1.5 Lens 2688 x 1520 resolution0.005 Lux / F1.6(color,30 IRE) 0 Lux / F1.6(IR ON) IR Illumination Up to 60m IR Distance , Built-in micro SD/SDHC/SDXC card slot,up to 128 GB,Inbuilt 64 GB micro SD card, DC12V, PoE (802.3 af)(Class 0) IP67 Ingress Protection IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets.Nos.25960.025960.03.0FalseNoneNoneFalseNoneFalse77880.00
3597803130997NoneMR 13NETWORK VIDEO RECORDER (NVR) Supply, Installation & Commissioning of 16 Channel NVR , 16Channels input,1 audio input, 1 audio output, 1HDMI, 1 VGA, Display Split 1/4/8/9/16, H.265/H.264/MJPEG/MPEG4, Resolution should supports up to 8MP, Backup Compatibility USB Device; 1 RJ-45 port (10/100/1000) 2 SATA ports, up to 8TB,Power supply Single, 100-240 VAC, 50/60 Hz.Nos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3597804130997NoneMR 144TB HDD (Surveillance or Enterprise Grade)Nos.17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3597805130997NoneMR 1516 x 100/1000 GbE Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 operating temperature supportNos.23600.023600.01.0FalseNoneNoneFalseNoneFalse23600.00
3597806130997NonePWD SR 2023-24 Volume 6 It No-8.12.6Supplying & Fixing of patch panel for LAN cabling 16 port 10/100/1000 patch panelNos.9145.09145.01.0FalseNoneNoneFalseNoneFalse9145.00
3597807130997NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableNos.303.26303.2613.0FalseNoneNoneFalseNoneFalse3942.380
3597808130997NoneMR 16Rj 45 connector with Crimping with 4 x 4 PVC boxesSet192.34192.3411.0FalseNoneNoneFalseNoneFalse2115.740
3597809130997NonePWD SR 2023-24 Volume 6 It No-8.4.3Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 9U with 450mm depthNos.10001.6810001.681.0FalseNoneNoneFalseNoneFalse10001.680
3597810130997NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripNos.1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3597811130997NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfNos.975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3597812130997NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanNos.1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3597813130997NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04265.0FalseNoneNoneFalseNoneFalse24390.60
3597814130997NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84390.0FalseNoneNoneFalseNoneFalse17487.60
3597815130997NoneMR 17Supplying & Fixing of 32" HD TV with HDMI Cable & Acessories ( Fixing option Wall Mount & Table Mount both option required)Each35400.035400.01.0FalseNoneNoneFalseNoneFalse35400.00
3597816130997NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cable.m44.8444.84650.0FalseNoneNoneFalseNoneFalse29146.00
3597817130997NonePWD SR 2023-24 Volume 6 It No-8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pairm24.7824.78320.0FalseNoneNoneFalseNoneFalse7929.60
3597818130997NonePWD SR 2023-24 Volume 6 It No-8.4.4Supplying & Fixing of sitch mountng rack with power manager & Cable manager. 12U with 450mm depthNos.10425.310425.31.0FalseNoneNoneFalseNoneFalse10425.30
3597819130997NonePWD SR 2023-24 Volume 6 It No-8.9.10Supplying fixing of Networking Switches 24 Port 10/100/1000 SwitchEach8749.78749.71.0FalseNoneNoneFalseNoneFalse8749.70
3597820130997NonePWD SR 2023-24 Volume 6 It No-8.5Supplying & Fixing of Power stripEach1719.261719.261.0FalseNoneNoneFalseNoneFalse1719.260
3597821130997NonePWD SR 2023-24 Volume 6 It No-8.6Supplying of shelfEach975.86975.861.0FalseNoneNoneFalseNoneFalse975.860
3597822130997NonePWD SR 2023-24 Volume 6 It No-8.8Supplying & Fixing of FanEach1426.621426.621.0FalseNoneNoneFalseNoneFalse1426.620
3597823130997NonePWD SR 2023-24 Volume 6 It No-8.10.1Supplying &fixing of I/Osocket, face plate with back box Single I/OEach578.2578.28.0FalseNoneNoneFalseNoneFalse4625.60
3597824130997NonePWD SR 2023-24 Volume 6 It No-8.10.2Supplying &fixing of I/Osocket, face plate with back box Double I/OEach649.0649.015.0FalseNoneNoneFalseNoneFalse9735.00
3597825130997NonePWD SR 2023-24 Volume 6 It No-8.11.2Supplying &fixing of 2mtr cat 6 Patch CableEach303.26303.2622.0FalseNoneNoneFalseNoneFalse6671.720
3597826130997NonePWD SR 2023-24 Volume 6 It No-8.11.3Supplying &fixing of 3mtr cat 6 Patch CableEach390.58390.5822.0FalseNoneNoneFalseNoneFalse8592.760
3597827130997NonePWD SR 2023-24 Volume 6 It No-8.12.5Supplying & Fixing of patch panel for LAN cabling 24 port 10/100/1000 patch panelEach9322.09322.01.0FalseNoneNoneFalseNoneFalse9322.00
3597828130997NonePWD SR 2023-24 Volume 6 It No-3.6.11Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socketEach184.08184.086.0FalseNoneNoneFalseNoneFalse1104.480
3597829130997NonePWD SR 2023-24 Volume 6 It No-8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.m51.9251.92180.0FalseNoneNoneFalseNoneFalse9345.60
3597830130997NonePWD SR 2023-24 Volume 6 It No-8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 pair krone module with MDF BOXEach451.94451.941.0FalseNoneNoneFalseNoneFalse451.940
3597831130997NonePWD SR 2023-24 Volume 6 It No-1.2.2Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thickm92.0492.04450.0FalseNoneNoneFalseNoneFalse41418.00
3597832130997NoneMR 18Supply & Fixing of GbESpeed Wifi Router, PoE Support.Each11800.011800.02.0FalseNoneNoneFalseNoneFalse23600.00
3597833130997NoneMR 198 x 100/1000 Base-T 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 NosEach17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
3597834130997NoneMR 20EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , 2Analog Trunk Lines 30 Analogue ExtensionsNos112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3597835130997NoneMR 2110 line IPM with LED IndicationsNos2950.02950.02.0FalseNoneNoneFalseNoneFalse5900.00
3597836130997NoneMR 22Analog PhonesNos2065.02065.015.0FalseNoneNoneFalseNoneFalse30975.00
3597837130997NoneMR 23Supply,Installation,Testing & Commissioning of Facial recognition with Biometric reader, Storage Capacity face, Finger & Card 10K, Communication TCP/IP, WiFi & USB, Dual- Core Processor 1.2GHz, Linux OS, Verification time 1Second, recognition distance 0.5-2mtrs, 512MB RAM, 8GB ROM, Wiegand IN & OUT, Exit reader Support, DC 12V /2A.Nos41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3597838130997NoneMR 24Supply & Fixing of PC , T & A Software,Nos64900.064900.01.0FalseNoneNoneFalseNoneFalse64900.00
3597839130997NonePWD SR 2023-24 Volume 6 It No-8.1Supplying and drawing UTP-CAT 6E LAN cableNos44.8444.8450.0FalseNoneNoneFalseNoneFalse2242.00
3597840130997NoneCSR 23-24 Page No-20 It No-45.04EXTERNAL ELECTRIFICATION: 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 SqmmSet4417.924417.926.0FalseNoneNoneFalseNoneFalse26507.520
3597841130997NoneCSR 23-24 Page No-20 It No-45.07Heat Shrinkable Outdoor Type Cable Termination 3x95 Sqmm Kit for XLPE CableSet4799.064799.062.0FalseNoneNoneFalseNoneFalse9598.120
3597842130997NoneCSR 23-24 Page No-52 It No-22.04Making and Fixing pot head for HT Cable only Heat shrinkable type 3x95 to 3x150 SqmmNo3136.443136.448.0FalseNoneNoneFalseNoneFalse25091.520
3597843130997NoneCSR 23-24 Page No-15 It No-36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia)Km1049805.881049805.880.12FalseNoneNoneFalseNoneFalse125976.70560
3597844130997NoneCSR 23-24 Page No-52 It No-21.01Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff 3x95 to 150 SqmmKm72359.9672359.960.12FalseNoneNoneFalseNoneFalse8683.19520
3597845130997NoneCSR 23-24 Page No-16 It No-39.01Compact RMU (VCB / SF6 Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC-62271/IS-3427 3 Way RMU 2OD + 1VL ( One Incomer + One Breakers + One Outgoing)Unit648469.0648469.01.0FalseNoneNoneFalseNoneFalse648469.00
3597846130997NoneCSR 23-24 Page No-26 It No-58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)Unit287296.96287296.961.0FalseNoneNoneFalseNoneFalse287296.960
3597847130997NoneCSR 23-24 Page No-23 It No-53.1HT 3 Phase 4 Wire Static Meter (CT, PT Operated) 3 x 63.5 V, 1 Amps 0.2s Accuracy Class with RS-485 & ABT featuresNo16344.1816344.183.0FalseNoneNoneFalseNoneFalse49032.540
3597848130997NoneCSR 23-24 Page No-23 It No-53.02CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port BIDIRECTIONAL (Used for Boundary Metering)No23558.723558.73.0FalseNoneNoneFalseNoneFalse70676.10
3597849130997NoneCSR 23-24 Page No-17 It No-41.01Load Break Switch with PanelNo86422.0286422.021.0FalseNoneNoneFalseNoneFalse86422.020
3597850130997NoneCSR 23-24 Page No-7 It No-12.16Distribution Transformer - 3 Phase,11kV/433 - staked CRGO Core with Oil as per IS - 1180 (Part - 1) : 2014 100 kVA, Aluminium wdg, star2 (5 Star) B. CABLE ENTRY TYPENo268217.54268217.541.0FalseNoneNoneFalseNoneFalse268217.540
3597851130997NoneCSR 21-22 Page No-2 0f 14 It No-4.06Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.No35825.9835825.982.0FalseNoneNoneFalseNoneFalse71651.960
3597852130997NoneCSR 21-22 Page No-22 It No-4.06 a)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 KgsNo1732.241732.244.0FalseNoneNoneFalseNoneFalse6928.960
3597853130997NoneCSR 21-22 Page No-4 of 4 It No-4.06 b)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs Rod TypeSet3418.463418.464.0FalseNoneNoneFalseNoneFalse13673.840
3597854130997NoneChapter-12 Page No-55 It No-12.60.3Using 10ft. Copper bonded rod with backfill compound.No10022.9210022.924.0FalseNoneNoneFalseNoneFalse40091.680
3597855130997NoneCSR 21-22 Page No-22 It No-51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo797.68797.6812.0FalseNoneNoneFalseNoneFalse9572.160
3597856130997NoneCSR 21-22 Page No-22 It No-51.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag365.8365.812.0FalseNoneNoneFalseNoneFalse4389.60
3597857130997NoneCSR 23-24 Page No-23 It No-51.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNo2562.962562.9610.0FalseNoneNoneFalseNoneFalse25629.60
3597858130997NoneCSR 23-24 Page No-23 It No-51.05Bentonite clay slurry for earthing in 50 Kg BagBag434.24434.2410.0FalseNoneNoneFalseNoneFalse4342.40
3597859130997NoneCSR 23-24 Page No-23 It No-55.01Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 MtrNo610.06610.065.0FalseNoneNoneFalseNoneFalse3050.30
3597860130997NonePage No-43 It No-1.6.1Digging of Pit for providing GI Pipe type Earthing Ordinary SoilNo895.62895.6210.0FalseNoneNoneFalseNoneFalse8956.20
3597861130997NonePage No-43 It No-1.6.2Digging of Pit for providing GI Pipe type Earthing Hard SoilNo3528.23528.24.0FalseNoneNoneFalseNoneFalse14112.80
3597862130997NoneChapter-5 Page No-20 It No-5.42.1Fabricating supplying and mounting MS CRCA box made out ..SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.590.5935000.0FalseNoneNoneFalseNoneFalse20650.00
3597863130997NoneChapter-5 Page No-20 It No-5.40.2Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4x30x10 mm Aluminium Stripsm4053.34053.34.0FalseNoneNoneFalseNoneFalse16213.20
3597864130997NoneChapter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mmm654.9654.912.0FalseNoneNoneFalseNoneFalse7858.80
3597865130997NoneChapter-5 Page No-17 It No-5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35KAEach25241.3825241.381.0FalseNoneNoneFalseNoneFalse25241.380
3597866130997NoneChapter-5 Page No-17 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.73.0FalseNoneNoneFalseNoneFalse1469.10
3597867130997NoneChapter-5 Page No-18 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN - For TVSS ConnectivityEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3597868130997NoneChapter-5 Page No-19 It No-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3597869130997NoneChapter-5 Page No-18 It No-5.22Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each533.36533.361.0FalseNoneNoneFalseNoneFalse533.360
3597870130997NoneChapter-5 Page No-18 It No-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3597871130997NoneChapter-5 Page No-18 It No-5.26Supplying, fixing and wiring 0 to 1500A CT operated AC analog type ammeter without CTEach566.4566.43.0FalseNoneNoneFalseNoneFalse1699.20
3597872130997NoneChapter-5 Page No-19 It No-5.27Supplying, fixing and wiring rotary selector switch suitable for AmmeterEach236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
3597873130997NoneChapter-5 Page No-19 It No-5.28Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach188.8188.82.0FalseNoneNoneFalseNoneFalse377.60
3597874130997NoneChapter-2 Page No-5 It No-2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2m30.6830.6825.0FalseNoneNoneFalseNoneFalse767.00
3597875130997NoneChapter-2 Page No-5 It No-2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2m49.5649.5610.0FalseNoneNoneFalseNoneFalse495.60
3597876130997NoneLeast Quotation RateSupplying, fixing and wiring 3 Phase TVSSEach16520.016520.01.0FalseNoneNoneFalseNoneFalse16520.00
3597877130997NoneCSR 21-22 Page No-23 of 27 It No-66.01Cable Covering Tile 125x250x40 mmPer Km11800.011800.01.0FalseNoneNoneFalseNoneFalse11800.00
3597878130997NoneCSR 21-22 Page No-23 of 27 It No-66.02Cable Covering Tile 125x125x40 mmPer Km5900.05900.01.0FalseNoneNoneFalseNoneFalse5900.00
3597879130997NoneCSR 21-22 Page No-23 of 27 It No-66.03RCC Hume Pipe 2000 mm long 150 mm DiaNo354.0354.08.0FalseNoneNoneFalseNoneFalse2832.00
3597880130997NoneCSR 21-22 Page No-23 of 27 It No-66.04RCC Hume Pipe 2000 mm long 200 mm DiaNo448.4448.410.0FalseNoneNoneFalseNoneFalse4484.00
3597881130997NoneCSR 21-22 Page No-23 of 27 It No-66.05Collars for RCC Hume Pipe 150 mm DiaNo94.494.44.0FalseNoneNoneFalseNoneFalse377.60
3597882130997NoneCSR 21-22 Page No-23 of 27 It No-66.06Collars for RCC Hume Pipe 200 mm DiaNo118.0118.04.0FalseNoneNoneFalseNoneFalse472.00
3597883130997NoneCSR 21-22 Page No-23 of 27 It No-66.19Route & Joint indicating slab with MS Anchor rodNo153.4153.45.0FalseNoneNoneFalseNoneFalse767.00
3597884130997NoneCSR 21-22 Page No-23 of 27 It No-66.20Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 MtrRoll149.86149.865.0FalseNoneNoneFalseNoneFalse749.30
3597885130997NoneCSR 21-22 Page No-23 of 27 It No-66.21Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 MtrRoll138.06138.065.0FalseNoneNoneFalseNoneFalse690.30
3597886130997NonePage No-3 of 4 It No-XXVSpiral Earth ElectrodeSet375.24375.2415.0FalseNoneNoneFalseNoneFalse5628.60
3597887130997NonePage No-3 of 4 It No-XXVIICaution/Danger BoardNo234.82234.822.0FalseNoneNoneFalseNoneFalse469.640
3597888130997NoneChpter-12 Page No-54 It No-12.58.225x3mm GI stripm96.7696.7680.0FalseNoneNoneFalseNoneFalse7740.80
3597889130997NoneChpter-12 Page No-54 It No-12.58.325x6mm GI stripm151.04151.0460.0FalseNoneNoneFalseNoneFalse9062.40
3597890130997NoneChpter-12 Page No-55 It No-12.58.6600x600x3mm GI PlateEach1032.51032.510.0FalseNoneNoneFalseNoneFalse10325.00
3597891130997NoneChpter-12 Page No-55 It No-12.58.725x3mm Copper stripm672.6672.660.0FalseNoneNoneFalseNoneFalse40356.00
3597892130997NoneChpter-12 Page No-55 It No-12.58.11600x600x3mm Copper plateEach8756.788756.784.0FalseNoneNoneFalseNoneFalse35027.120
3597893130997NoneLeast Quotation Rate 1Chain Link Fencing-Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting (excluding cost of earth work and concreate).m1593.01593.030.0FalseNoneNoneFalseNoneFalse47790.00
3597894130997NoneLeast Quotation Rate 2Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,Sqm1003.01003.010.0FalseNoneNoneFalseNoneFalse10030.00
3597895130997NoneChpter-5 Page No-20 It No-5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mmm654.9654.910.0FalseNoneNoneFalseNoneFalse6549.00
3597896130997NoneLeast Quotation Rate 3Supply Intstallation & Spreading of 40mm thick metal, 80mm depth in outdoor H.T yardSqm826.0826.016.0FalseNoneNoneFalseNoneFalse13216.00
3597897130997NoneLeast Quotation Rate 4Supplying of two bucket stand alongwith buckets. CompleteEach743.4743.42.0FalseNoneNoneFalseNoneFalse1486.80
3597898130997NoneLeast Quotation Rate 5Rubber Hand Gloves 15 kV,SEAMLESS Confirming to ISPair200.6200.62.0FalseNoneNoneFalseNoneFalse401.20
3597899130997NoneCSR 21-22 Page No- It No-21 OF 27Supplying of first aid box. CompleteEach1300.361300.362.0FalseNoneNoneFalseNoneFalse2600.720
3597900130997NoneLeast Quotation Rate 7Supplying of FIRST AID CHART with lamination. CompleteEach265.5265.52.0FalseNoneNoneFalseNoneFalse531.00
3597901130997NonePWD SR 2023-24 Volume 6 It No-9.3.5UPS Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPSEach122212.6122212.61.0FalseNoneNoneFalseNoneFalse122212.60
3597902130997NonePWD SR 2023-24 Volume 6 It No-9.5.8Supplying, installation,testing & commissioning of 12v DC, AH batteries in poly propylene container for U.P.S Low maintenance Tubular batteries. 120 AH capacityEach18306.5218306.5216.0FalseNoneNoneFalseNoneFalse292904.320
3597903130997NonePWD SR 2023-24 Volume 6 It No-6.9.5HVAC : Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit 4.0 TR Cassette 3 PhNo166680.9166680.92.0FalseNoneNoneFalseNoneFalse333361.80
3597904130997NonePWD SR 2023-24 Volume 6 It No-6.13.2Cassette Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tubem2080.342080.3420.0FalseNoneNoneFalseNoneFalse41606.80
3597905130997NonePWD SR 2023-24 Volume 6 It No-6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.Each5877.585877.582.0FalseNoneNoneFalseNoneFalse11755.160
3597906130997NonePWD SR 2023-24 Volume 6 It No-6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.Each5398.55398.52.0FalseNoneNoneFalseNoneFalse10797.00
3597907130997NonePWD SR 2023-24 Volume 6 It No-4.4.5STREET LIGHTING ; Fabricating, supplying and erection of ... ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for ....... m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 7 Meters- Top 75mm and botton 145mm diaEach17700.017700.04.0FalseNoneNoneFalseNoneFalse70800.00
3597908130997NonePWD SR 2023-24 Volume 6 It No-4.6.1Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM diaEach2006.02006.04.0FalseNoneNoneFalseNoneFalse8024.00
3597909130997NonePWD SR 2023-24 Volume 6 It No-11.8.3LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded & is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr @ Lumen maintanance of 70%. CCT 5500 K, IP 66 optical and electrical compartment & impact resistance of complete luminare- IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A& Surge Protection - Min 4 KV alongwith over voltage / overload, short circuit/ miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 / 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322/IEC 60598, LM 79 & LM 80 Adherance with ROHS .UL approved MCPCB . Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 / m/w at Fixture Efficiency 80 /m/w with nominal CRI 75 Luminarie manufacture should have in-house facility accredited by NABL/ CPRI & any government certified agency & Design with supplier word mark/ name shall be Engraved/ Embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1/ B2 Roads as per IS 1944 Part & Part II LED Streetlight 70wattsEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3597910130997NonePWD SR 2023-24 Volume 6 It No-13.5Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires.Each191.16191.164.0FalseNoneNoneFalseNoneFalse764.640
3597911130997NonePWD SR 2023-24 Volume 6 It No-32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 ( BESCOM SR - 2021-2022 ) 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km139244.72139244.720.15FalseNoneNoneFalseNoneFalse20886.7080
3597912130997NonePWD SR 2023-24 Volume 6 It No-21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff ( BESCOM SR - 2021-2022 ).LT Cable 2.5 to 25 SqmmKm24645.4824645.480.15FalseNoneNoneFalseNoneFalse3696.8220
3597913130997NonePWD SR 2023-24 Volume 6 It No-2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 2.5 sqmmm133.34133.34210.0FalseNoneNoneFalseNoneFalse28001.40
3597914130997NonePWD SR 2023-24 Volume 6 It No-2.5.15Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 sqmmm202.96202.96150.0FalseNoneNoneFalseNoneFalse30444.00
3597915130997NoneMR 1Supply and laying double walled corrugated (DWC) HDPE pipe inculding all necessary connecting sockets / couplings / Tees / bends / End-caps of same materials in existing trench as per is 14930 part-11 suitable for drawing underground cable 63mm OD / 50MM IDm300.9300.920.0FalseNoneNoneFalseNoneFalse6018.00
3597916130997NonePWD SR 2023-24 Volume 6 It No-6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)(70/6) ( SR 2019-2020 )m89.6889.68150.0FalseNoneNoneFalseNoneFalse13452.00
3597917130997NonePWD SR 2023-24 Volume 6 It No-6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. ( SR 2019-2020 )m118.0118.050.0FalseNoneNoneFalseNoneFalse5900.00
3597918130997NonePWD SR 2023-24 Volume 6 It No-11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70WEach7986.247986.246.0FalseNoneNoneFalseNoneFalse47917.440
3597919130997NonePWD SR 2023-24 Volume 6 It No-11.7.2Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 11.7. 1 LED Post Top Lantern with 25 W LED Post Top Lantern with 25/30 WattsEach9111.969111.966.0FalseNoneNoneFalseNoneFalse54671.760
3597920130997NonePWD SR 2023-24 V-3 Page No-9 It No-2.5ACC ROAD: Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.05FalseNoneNoneFalseNoneFalse511.2660
3597921130997NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depthCum117.7117.731.5FalseNoneNoneFalseNoneFalse3707.550
3597922130997NonePWD SR 2023-24 V-3 Page No-17 It No-305.3.4Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum130.09130.0931.5FalseNoneNoneFalseNoneFalse4097.8350
3597923130997NonePWD SR 2023-24 VI Page No-7 It No-1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum587.28587.2831.5FalseNoneNoneFalseNoneFalse18499.320
3597924130997NonePWD SR 2023-24 V-3 Page No-23 It No-4.2(v)Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 For Grading -V MaterialCum2922.82922.815.75FalseNoneNoneFalseNoneFalse46034.10
3597925130997NonePWDSR 2023-24 V3 Page No-49 It No-6.1Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.Cum6095.886095.8810.5FalseNoneNoneFalseNoneFalse64006.740
3597926130997NonePWDSR 2023-24 V3 Page No-43 (7) It No-6.2Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawingCum11107.6311107.6321.0FalseNoneNoneFalseNoneFalse233260.230
3597927130997NonePageNo 56 It No-8.10 MoRTH 803Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesSqm105.31105.3115.0FalseNoneNoneFalseNoneFalse1579.650
3597928130997NonePage No-123 It No-13.14MoRTH 800Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.Sqm87.9687.96448.0FalseNoneNoneFalseNoneFalse39406.080
3597929130997NonePWD SR 2023-24 V-3 Page No-146 It No-21A(6.1)Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stonem296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3597930130997NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.372.25FalseNoneNoneFalseNoneFalse16695.83250
3597931130997NonePWD Volume- 2 SR 2023-24 Page No-6 It No-1.5COMPOUND WALL : Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum370.46370.4677.15FalseNoneNoneFalseNoneFalse28580.9890
3597932130997NonePWD Volume- 1 SR 2023-24 Page No-15 It No-2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3713.64FalseNoneNoneFalseNoneFalse101213.84680
3597933130997NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Footing ConcreteCum8412.768412.768.7FalseNoneNoneFalseNoneFalse73191.0120
3597934130997NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Column ConcreteCum13242.3113242.318.02FalseNoneNoneFalseNoneFalse106203.32620
3597935130997NonePWD Volume- 1 SR 2021-22 Page No-15 It No-2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.For Plinth Beam ConcreteCum13242.3113242.318.01FalseNoneNoneFalseNoneFalse106070.90310
3597936130997NonePWD Volume- 2 SR 2023-24 Page No-18 It No-2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildingst110837.22110837.222.55FalseNoneNoneFalseNoneFalse282634.9110
3597937130997NonePWD Volume- 2 SR 2023-24 Page No-17 It No-6.33roviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1525.211525.21137.58FalseNoneNoneFalseNoneFalse209838.39180
3597938130997NonePWD Volume- 2 SR 2023-24 Page No-42 It No-8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm459.67459.67370.16FalseNoneNoneFalseNoneFalse170151.44720
3597939130997NonePWD Volume- 2 SR 2023-24 Page No-46 It No-8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm193.28193.28370.16FalseNoneNoneFalseNoneFalse71544.52480
3597940130997NonePWD SR 2023-24 V-5 Page No-140 It No-12.4BOREWELL Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in chargeNos6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3597941130997NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Upto 50 Mtrsm458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3597942130997NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above 50 Mtrs and upto 100 Mtr.m574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3597943130997NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above100 Mtrs. and upto 150 Mtr.m610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3597944130997NonePWD SR 2023-24 V-5 Page No-139 It No-12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every Above150 Mtrs. and upto 200 Mtr.m708.71708.7130.0FalseNoneNoneFalseNoneFalse21261.30
3597945130997NonePWD SR 2023-24 V-5 Page No-143 It No-12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m2394.992394.9925.0FalseNoneNoneFalseNoneFalse59874.750
3597946130997NonePWD SR 2023-24 V-5 Page No-155 It No-13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendmentsm681.45681.45200.0FalseNoneNoneFalseNoneFalse136290.00
3597947130997NonePWD SR 2023-24 V-5 Page No-143 It No-12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3597948130997NonePWD SR 2023-24 V-5 Page No-154 It No-12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in chargeNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3597949130997NonePWD SR 2023-24 95 Page No-18-19 SR It No-13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete)Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3597950130997NonePWD SR 2023-24 V-5 Page No-154 It No-13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 3.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"Nos34832.0134832.011.0FalseNoneNoneFalseNoneFalse34832.010
3597951130997NonePWD SR 2023-24 V-5 Page No-155 It No-13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Nos11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3597952130997NonePWD SR 2023-24 V-5 Page No-155 It No-13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3597953130997NonePWD SR 2023-24 V-5 Page No-155 It No-13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3597954130997NonePWD SR 2023-24 V-5 Page No-156 It No-13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work ---- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3597955130997NonePWD SR 2023 24 V 5 Page No-156 It No 13.34Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc. complete. as per specifications, with testing of as per instructions of engineer incharge of work etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.Each1796.551796.551.0FalseNoneNoneFalseNoneFalse1796.550
3597956130997NonePWD SR 2023-24 Page Ele Sr P No 12, It No-2.11.3Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirmining to table 3 class 5 of IS:8130-1984 and virgin grade PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP of GROUP-A(12/2.10)m121.42121.42259.0FalseNoneNoneFalseNoneFalse31447.780
3597957130997NonePWD SR 2023-24 V-5 Page No-20 It No-5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWGNos0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3597958130997NonePWD SR 2023-24 V-5 Page No-21 It No-5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.600mmx600mmx170mm.Nos17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3597959130997NonePWD SR 2023-24 Vol-6 It No-I No 6.6.6Supplying and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. - 500 x 500 x 65 mm (20" x 20" x 2.5") etc., complete as per directions of the Engineer-in-chargeNos361.79361.791.0FalseNoneNoneFalseNoneFalse361.790
3597960130997NonePWD SR 2023-24 Vol-6 It No-I No 6.16.5Supplying and fixing miniature circuit breakers/Isolators on existing MCB distribution boards using necessary fixing materials and wiring complete as directed by the Engineer-in-charge - 5 to 30 Amps Triple and NeutralNos2124.892124.891.0FalseNoneNoneFalseNoneFalse2124.890
3597961130997NonePWD SR 2023-24 Vol-6 It No-I No 6.5.1Supplying and fixing TPST with neutral link switches rewirable fuse type - Havels / Standard / Indo-Asian Crescent - 30 to 35 Amps, etc., complete as per directions of the Engineer-in-chargeNos2230.22230.21.0FalseNoneNoneFalseNoneFalse2230.20
3597962130997NonePWD SR 2023-24 Vol-6 It No-I No. 6.35Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery (48/6.35)Nos495.6495.61.0FalseNoneNoneFalseNoneFalse495.60
3597963130997NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.1RAIN WATER: Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m 1000 MM DiaCum299.83299.836.786FalseNoneNoneFalseNoneFalse2034.646380
3597964130997NonePWD SR 2023-24 V-1 Page No-5 It No-1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface levelled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m 1000 MM DiaCum320.9320.96.786FalseNoneNoneFalseNoneFalse2177.62740
3597965130997NonePWD SR 2023-24 V-2 Page No-175 It No-17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. 1000 MM DiaEach1391.391391.3928.0FalseNoneNoneFalseNoneFalse38958.920
3597966130997NonePWD SR 2023-24 V-2 Page No-175 It No-17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1241.471241.471.131FalseNoneNoneFalseNoneFalse1404.102570
3597967130997NonePWD SR 2023-24 V-2 Page No-175 It No-17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1469.451469.450.565FalseNoneNoneFalseNoneFalse830.239250
3597968130997NonePWD SR 2023-24 V-2 Page No-175 It No-17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 1000 MM DiaCum1476.881476.880.565FalseNoneNoneFalseNoneFalse834.43720
3597969130997NonePWD SR 2023-24 V-2 Page No-175 It No-17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 1000 MM DiaCum1659.021659.020.565FalseNoneNoneFalseNoneFalse937.34630
3597970130997NonePWD SR 2023-24 V-2 Page No-177 It No-17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. 1000 MM DiaSqm1449.631449.634.0FalseNoneNoneFalseNoneFalse5798.520
3597971130997NonePWD SR 2023-24 V- 3 Page No-9 It No-2.5(ii)ANQ UPTO PLINTH Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using Dozer A. In area of light jungle100 Sqm486.92486.921.0FalseNoneNoneFalseNoneFalse486.920
3597972130997NonePWD SR 2023-24 V-1 Page No-8 It No-1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depthCum117.7117.715.0FalseNoneNoneFalseNoneFalse1765.50
3597973130997NonePWD SR 2023-24 V-1 Page No-8 It No-1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum126.37126.3788.155FalseNoneNoneFalseNoneFalse11140.147350
3597974130997NonePWD SR 2023-24 V-1 Page No-8 It No-1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depthCum449.75449.7522.038FalseNoneNoneFalseNoneFalse9911.59050
3597975130997NonePWD SR 2023-24 V-1 Page No-9 It No-1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work.In Hard Rock ( requiring blasting) Depth upto 1.50mCum686.4686.42.203FalseNoneNoneFalseNoneFalse1512.13920
3597976130997NonePWD SR 2023-24 V-1 Page No-15 It No-2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum7420.377420.3715.807FalseNoneNoneFalseNoneFalse117293.788590
3597977130997NonePWD SR 2023-24 V-2 Page No-5 It No-4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm146.2146.282.0FalseNoneNoneFalseNoneFalse11988.40
3597978130997NonePWD SR 2023-24 V-1 Page No-7 It No-1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum329.57329.5788.155FalseNoneNoneFalseNoneFalse29053.243350
3597979130997NonePWD SR 2023-24 V-1 Page No-7 It No-1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 mCum536.48536.4811.18FalseNoneNoneFalseNoneFalse5997.84640
3597980130997NonePWD SR 2023-24 V-1 Page No-15 It No-2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( Footing RCC )Cum7850.37850.313.85FalseNoneNoneFalseNoneFalse108726.6550
3597981130997NonePWD SR 2023-24 V-1 Page No-16 It No-2.4.3Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns)Cum7850.37850.32.88FalseNoneNoneFalseNoneFalse22608.8640
3597982130997NonePWD SR 2023-24 V-1 Page No-16 It No-2.3.2Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam)Cum8028.728028.727.66FalseNoneNoneFalseNoneFalse61499.99520
3597983130997NonePWD SR 2023-24 V-1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)t110837.22110837.222.5FalseNoneNoneFalseNoneFalse277093.050
3597984130997NonePWD SR 2023-24 V-1 Page No-111 It No-1Form Work and Centering ( % On Finished Rate of Concrete per cum)Foundation upto Plinth a. Isolated (8%)Cum628.02628.0213.85FalseNoneNoneFalseNoneFalse8698.0770
3597985130997NonePWD SR 2023-24 V-1 Page No-111 It No-3Form Work and Centering ( % On Finished Rate of Concrete per cum) Foundation, Sub structure of Cross drainages (5%)Cum371.01371.0115.807FalseNoneNoneFalseNoneFalse5864.555070
3597986130997NonePWD SR 2023-24 V-1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%)Cum5495.215495.212.88FalseNoneNoneFalseNoneFalse15826.20480
3597987130997NonePWD SR 2023-24 V-1 Page No-111 It No-2Form Work and Centering ( % On Finished Rate of Concrete per cum) Plinth Beams of Buildings (50%)Cum4014.364014.367.66FalseNoneNoneFalseNoneFalse30749.99760
3597988130997NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2NQ ABOVE PLINTH Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(LINTEL -GROUND FLOOR)Cum8478.478478.471.24FalseNoneNoneFalseNoneFalse10513.30280
3597989130997NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (LINTEL -TERRACE FLOOR)Cum8563.268563.260.17FalseNoneNoneFalseNoneFalse1455.75420
3597990130997NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL -GROUND FLOOR)Cum8478.478478.470.65FalseNoneNoneFalseNoneFalse5511.00550
3597991130997NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CILL - TERRACE FLOOR)Cum8563.268563.260.1FalseNoneNoneFalseNoneFalse856.3260
3597992130997NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(STAIRCASE-GROUND FLOOR)Cum8478.478478.471.872FalseNoneNoneFalseNoneFalse15871.695840
3597993130997NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA -GROUND FLOOR)Cum8478.478478.470.445FalseNoneNoneFalseNoneFalse3772.919150
3597994130997NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(CHEJJA - TERRACE FLOOR)Cum8563.268563.260.06FalseNoneNoneFalseNoneFalse513.79560
3597995130997NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB -GROUND FLOOR)Cum8478.478478.4711.811FalseNoneNoneFalseNoneFalse100139.209170
3597996130997NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(SLAB - TERRACE FLOOR)Cum8563.268563.261.196FalseNoneNoneFalseNoneFalse10241.658960
3597997130997NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM -GROUND FLOOR)Cum8478.478478.477.65FalseNoneNoneFalseNoneFalse64860.29550
3597998130997NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(BEAM - TERRACE FLOOR)Cum8563.268563.261.45FalseNoneNoneFalseNoneFalse12416.7270
3597999130997NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN -GROUND FLOOR)Cum8478.478478.474.13FalseNoneNoneFalseNoneFalse35016.08110
3598000130997NonePWD SR 2023-24 V- 1 Page No-16 It No-2.5.2Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(COLUMN - TERRACE FLOOR)Cum8563.268563.262.42FalseNoneNoneFalseNoneFalse20723.08920
3598001130997NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) GROUND FLOORCum5934.935934.934.13FalseNoneNoneFalseNoneFalse24511.26090
3598002130997NonePWD SR 2023-24 V- 1 Page No-111 It No-9Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Columns / Shaft (Slip Centering)(70%) TERRACE FLOORCum5994.285994.282.42FalseNoneNoneFalseNoneFalse14506.15760
3598003130997NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)GROUND FLOORCum5087.085087.088.89FalseNoneNoneFalseNoneFalse45224.14120
3598004130997NonePWD SR 2023-24 V- 1 Page No-112 It No-14Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Beams, Lintels & Troughs of Aqueducts (60%)TERRACE FLOORCum5137.955137.951.62FalseNoneNoneFalseNoneFalse8323.4790
3598005130997NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) GROUND FLOORCum4239.234239.2311.811FalseNoneNoneFalseNoneFalse50069.545530
3598006130997NonePWD SR 2023-24 V- 1 Page No-112 It No-15Form Work and Centering ( % On Finished Rate of Concrete per cum) RCC Roof Slabs (50%) TERRACE FLOORCum4281.634281.631.196FalseNoneNoneFalseNoneFalse5120.829480
3598007130997NonePWD SR 2023-24 V- 1 Page No-112 It No-16Form Work and Centering ( % On Finished Rate of Concrete per cum) Staircase and other similar structures(50%) GROUND FLOORCum4239.234239.231.872FalseNoneNoneFalseNoneFalse7935.838560
3598008130997NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )GROUND FLOORCum3815.313815.311.09FalseNoneNoneFalseNoneFalse4158.68790
3598009130997NonePWD SR 2023-24 V- 1 Page No-112 It No-19Form Work and Centering ( % On Finished Rate of Concrete per cum) Chejjas, Canopy & Other Architectural projections of minor sections ( 45% )TERRACE FLOORCum3853.463853.460.16FalseNoneNoneFalseNoneFalse616.55360
3598010130997NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)GROUND FLOORt110837.22110837.223.06FalseNoneNoneFalseNoneFalse339161.89320
3598011130997NonePWD SR 2023-24 V- 1 Page No-18 It No-2.11aSupplying, fitting and placing TMT FE 550 / 550 Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft Annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Buildings)TERRACE FLOORt111945.59111945.590.75FalseNoneNoneFalseNoneFalse83959.19250
3598012130997NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications.GROUND FLOORCum9873.599873.5926.03FalseNoneNoneFalseNoneFalse257009.54770
3598013130997NonePWD SR 2023-24 V-2 Page No-14 It No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.specifications..TERRACE FLOORCum9972.329972.3212.79FalseNoneNoneFalseNoneFalse127545.97280
3598014130997NonePWD SR 2023-24 V-2 Page No-14 It No-6.14Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm1313.341313.349.147FalseNoneNoneFalseNoneFalse12013.120980
3598015130997NonePWD SR 2023-24 V-2 Page No-100 It No-12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum122431.78122431.780.143FalseNoneNoneFalseNoneFalse17507.744540
3598016130997NonePWD SR 2023-24 V-2 Page No-105 It No-12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm4115.954115.958.82FalseNoneNoneFalseNoneFalse36302.6790
3598017130997NonePWD SR 2023-24 V-2 Page No-103 It No-12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1258.821258.824.0FalseNoneNoneFalseNoneFalse5035.280
3598018130997NonePWD SR 2023-24 V-2 Page No-105 It No-12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos148.68148.685.0FalseNoneNoneFalseNoneFalse743.40
3598019130997NonePWD SR 2023-24 V-2 Page No-105 It No-12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1380.241380.245.0FalseNoneNoneFalseNoneFalse6901.20
3598020130997NonePWD SR 2023-24 V-2 Page No-105 It No-12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1303.421303.424.0FalseNoneNoneFalseNoneFalse5213.680
3598021130997NonePWD SR 2023-24 V-2 Page No-105 It No-12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos293.64293.648.0FalseNoneNoneFalseNoneFalse2349.120
3598022130997NonePWD SR 2023-24 V-2 Page No-105 It No-12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos161.07161.0710.0FalseNoneNoneFalseNoneFalse1610.70
3598023130997NonePWD SR 2023-24 V-2 Page No-105 It No-12.64Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gmsNos68.1468.144.0FalseNoneNoneFalseNoneFalse272.560
3598024130997NonePWD SR 2023-24 V-2 Page No-107 It No-12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type):.Nos340.72340.7220.0FalseNoneNoneFalseNoneFalse6814.40
3598025130997NonePWD SR 2023-24 V-2 Page No-107 It No-12.76.3Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmNos358.07358.074.0FalseNoneNoneFalseNoneFalse1432.280
3598026130997NonePWD SR 2023-24 V-2 Page No-69 It No-10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOORNos74.3474.3416.0FalseNoneNoneFalseNoneFalse1189.440
3598027130997NonePWD SR 2023-24 V-2 Page No-205 It No-20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOORm64.4264.4222.2FalseNoneNoneFalseNoneFalse1430.1240
3598028130997NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm8343.428343.4212.24FalseNoneNoneFalseNoneFalse102123.46080
3598029130997NonePWD SR 2023-24 V-2 Page No-110 It No-12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)TERRACE FLOORSqm8426.868426.861.8FalseNoneNoneFalseNoneFalse15168.3480
3598030130997NonePWD SR 2023-24 V-2 Page No-109 It No-12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOORSqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3598031130997NonePWD SR 2023-24 V-2 Page No-104 It No-12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.GROUND FLOORSqm394.0394.03.15FalseNoneNoneFalseNoneFalse1241.10
3598032130997NonePWD SR 2023-24 V-2 Page No-104 It No-12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.'-do- with both side prelamGROUND FLOORSqm2931.472931.473.15FalseNoneNoneFalseNoneFalse9234.13050
3598033130997NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOORKg208.15208.15272.16FalseNoneNoneFalseNoneFalse56650.1040
3598034130997NonePWD SR 2023-24 V-2 Page No-86 It No-11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOORKg210.23210.2337.8FalseNoneNoneFalseNoneFalse7946.6940
3598035130997NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm61.9561.9512.96FalseNoneNoneFalseNoneFalse802.8720
3598036130997NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm62.5662.561.8FalseNoneNoneFalseNoneFalse112.6080
3598037130997NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm206.91206.9112.96FalseNoneNoneFalseNoneFalse2681.55360
3598038130997NonePWD SR 2023-24 V-2 Page No-48 It No-8.41Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm208.98208.981.8FalseNoneNoneFalseNoneFalse376.1640
3598039130997NonePWD SR 2023-24 V-2 Page No-47 It No-8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm65.6665.668.82FalseNoneNoneFalseNoneFalse579.12120
3598040130997NonePWD SR 2023-24 V-2 Page No-54 It No-8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOORSqm838.8838.88.82FalseNoneNoneFalseNoneFalse7398.2160
3598041130997NonePWD SR 2023-24 V-2 Page No-84 It No-11.26.3Providing and fixing hand rail of approved size by welding etc.steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeGROUND FLOORKg226.73226.73168.0FalseNoneNoneFalseNoneFalse38090.640
3598042130997NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm261.42261.4242.0FalseNoneNoneFalseNoneFalse10979.640
3598043130997NonePWD SR 2023-24 V-2 Page No-43 It No-8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm264.04264.0410.0FalseNoneNoneFalseNoneFalse2640.40
3598044130997NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm315.94315.94235.785FalseNoneNoneFalseNoneFalse74493.91290
3598045130997NonePWD SR 2023-24 V-2 Page No-41 It No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm319.1319.160.6FalseNoneNoneFalseNoneFalse19337.460
3598046130997NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm453.47453.47120.42FalseNoneNoneFalseNoneFalse54606.85740
3598047130997NonePWD SR 2023-24 V-2 Page No-42 It No-8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)Sqm458.0458.056.1FalseNoneNoneFalseNoneFalse25693.80
3598048130997NonePWD SR 2023-24 V-2 Page No-41 It No-8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)Sqm365.5365.540.8FalseNoneNoneFalseNoneFalse14912.40
3598049130997NonePWD SR 2023-24 V-2 Page No-65 It No-9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOORSqm1795.311795.3140.8FalseNoneNoneFalseNoneFalse73248.6480
3598050130997NonePWD SR 2023-24 V-2 Page No-60 It No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOORSqm1418.651418.6579.55FalseNoneNoneFalseNoneFalse112853.60750
3598051130997NonePWD SR 2023-24 V-2 Page No-60 It No-9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., completeGROUND FLOOR .Sqm1101.471101.476.87FalseNoneNoneFalseNoneFalse7567.09890
3598052130997NonePWD SR 2023-24 V-2 Page No-64 It No-9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR .Sqm6601.396601.3916.44FalseNoneNoneFalseNoneFalse108526.85160
3598053130997NonePWD SR 2023-24 V-2 Page No-69 It No-10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2(GROUND FLOOR)Sqm4877.944877.946.0FalseNoneNoneFalseNoneFalse29267.640
3598054130997NonePWD SR 2023-24 V-2 Page No-69 It No-10.2Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.GROUND FLOORm406.39406.395.0FalseNoneNoneFalseNoneFalse2031.950
3598055130997NonePWD SR 2023-24 V-2 Page No-69 It No-10.4Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.GROUND FLOORm732.24732.247.2FalseNoneNoneFalseNoneFalse5272.1280
3598056130997NonePWD SR 2023-24 V-2 Page No-27 It No-7.40.2Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.GROUND FLOORSqm2118.692118.696.87FalseNoneNoneFalseNoneFalse14555.40030
3598057130997NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOORSqm123.9123.9277.785FalseNoneNoneFalseNoneFalse34417.56150
3598058130997NonePWD SR 2023-24 V-2 Page No-50 It No-8.51Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.TERRACE FLOORSqm125.13125.1370.6FalseNoneNoneFalseNoneFalse8834.1780
3598059130997NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..GROUND FLOORSqm65.6665.66277.785FalseNoneNoneFalseNoneFalse18239.36310
3598060130997NonePWD SR 2023-24 V-2 Page No-51 It No-8.55.2Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge..TERRACE FLOORSqm66.3266.3270.6FalseNoneNoneFalseNoneFalse4682.1920
3598061130997NonePWD SR 2023-24 V-2 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOORSqm136.29136.29277.785FalseNoneNoneFalseNoneFalse37859.317650
3598062130997NonePWD SR 2023-24 V11 Page No-50 It No-8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.TERRACE FLOORSqm137.65137.6570.6FalseNoneNoneFalseNoneFalse9718.090
3598063130997NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOORSqm215.58215.58120.42FalseNoneNoneFalseNoneFalse25960.14360
3598064130997NonePWD SR 2023-24 V11 Page No-46 It No-8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOORSqm217.74217.7456.1FalseNoneNoneFalseNoneFalse12215.2140
3598065130997NoneApproved RateProviding and laying 75mm thick (average) M20 grade concrete protection screed mixed with Water proofing admixture conplast WL of Fosroc make or equivalent as per manufacturers specifications approved by consultants. Concrete shall laid be in panels along with polypropylene fibres( 0.90kg/Cum), 12mm and down size aggregates and coarse sand over waterproofing to proper Slopes including top surface shall be finished with 12mm thick waterproof plaster with CM 1:3. The groves to be made about 6mmX10mm size at 5mX5m intervals including filling the same with weather resistant sealent like (Colpor - 200 from Fosroc chemicals or (Pidilite / Fosroc / BASF / Asian Paints or equivalent). Measurements shall be considered as floor area only. NOTE: Only surface areas shall be considered and necessary shop drawings shall be submitted by contractor for consultants approval prior to execution.TERRACE FLOORSqm774.67774.6782.0FalseNoneNoneFalseNoneFalse63522.940
3598066130997NonePWD SR 2023-24 V11 Page No-54 It No-8.8Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.m81.7781.77318.0FalseNoneNoneFalseNoneFalse26002.860
3598067130997NonePWD SR 2023-24 V11 Page No-43 It No-8.16.1Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster Meshm42.1242.12318.0FalseNoneNoneFalseNoneFalse13394.160
3598068130997NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(GROUND FLOOR)Sqm5255.835255.832.52FalseNoneNoneFalseNoneFalse13244.69160
3598069130997NonePWD SR 2023-24 V-2 Page No-75 It No-11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(TERRACE FLOOR)Sqm5308.395308.392.52FalseNoneNoneFalseNoneFalse13377.14280
3598070130997NonePWD SR V-2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(GROUND FLOOR)m9.919.9136.0FalseNoneNoneFalseNoneFalse356.760
3598071130997NonePWD V-2SR 2021-22 Page No-44 It No-8.16.4Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(TERRACE FLOOR)m10.0110.0132.94FalseNoneNoneFalseNoneFalse329.72940
3598072130997NoneOLD SR 18-19 It No-4.55Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete (excluding the cost of steel and fabrication chargesSqm729.24729.2411.07FalseNoneNoneFalseNoneFalse8072.68680
3598073130997NonePWD SR 2023-24 V-2 Page No-131 It No-14.3.1NQ WATER SUPPLY Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach7405.57405.51.0FalseNoneNoneFalseNoneFalse7405.50
3598074130997NoneLQ RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).Each2183.02183.01.0FalseNoneNoneFalseNoneFalse2183.00
3598075130997NonePWD SR 2023-24 V-2 Page No-136 It No-14.34.1Providing and fixing toilet paper holder :C.P. brassEach753.31753.311.0FalseNoneNoneFalseNoneFalse753.310
3598076130997NonePWD SR 2023-24 V-2 Page No-117 It No-13.2.2Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNos.377.89377.891.0FalseNoneNoneFalseNoneFalse377.890
3598077130997NonePWD SR 2023-24 V-2 Page No-132 It No-14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach3173.073173.072.0FalseNoneNoneFalseNoneFalse6346.140
3598078130997NonePWD SR 2023-24 V-2 Page No-133 It No-14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mmNos.5986.845986.841.0FalseNoneNoneFalseNoneFalse5986.840
3598079130997NonePWD SR 2023-24 V-2 Page No-140 It No-14.62.aProviding and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class EconomyNos.2388.792388.791.0FalseNoneNoneFalseNoneFalse2388.790
3598080130997NonePWD SR 2023-24 V-2 Page No-137 It No-14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each614.54614.543.0FalseNoneNoneFalseNoneFalse1843.620
3598081130997NonePWD SR 2023-24 V-2 Page No-120 It No-13.22.2Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lidNos.250.27250.275.0FalseNoneNoneFalseNoneFalse1251.350
3598082130997NonePWD SR 2023-24 V-2 Page No-135 It No-14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Nos.1003.591003.593.0FalseNoneNoneFalseNoneFalse3010.770
3598083130997NonePWD SR 2023-24 V-2 Page No-136 It No-14.32.2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mmEach1261.31261.32.0FalseNoneNoneFalseNoneFalse2522.60
3598084130997NonePWD SR 2023-24 V-2 Page No-136 It No-14.29Providing and fixing 100 mm sand cast Iron grating for gully trap.Each58.2358.234.0FalseNoneNoneFalseNoneFalse232.920
3598085130997NonePWD SR 2023-24 V-2 Page No-136 It No-14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste linesm113.98113.986.0FalseNoneNoneFalseNoneFalse683.880
3598086130997NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipesm358.07358.0712.0FalseNoneNoneFalseNoneFalse4296.840
3598087130997NonePWD SR 2023-24 V-2 Page No-128 It No-13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipesm477.01477.016.0FalseNoneNoneFalseNoneFalse2862.060
3598088130997NoneLQ RateAir Vent Cowel -75 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3598089130997NoneLQ RateAir Vent Cowel -110 mmNos.590.0590.02.0FalseNoneNoneFalseNoneFalse1180.00
3598090130997NonePWD SR 2023-24 V-2 Page No-125 It No-13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter.m360.54360.544.0FalseNoneNoneFalseNoneFalse1442.160
3598091130997NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipesm469.58469.5825.0FalseNoneNoneFalseNoneFalse11739.50
3598092130997NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc25 mm nominal dia pipesm591.0591.010.0FalseNoneNoneFalseNoneFalse5910.00
3598093130997NonePWD SR 2023-24 V-2 Page No-122 It No-13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes32 mm nominal dia pipesm690.12690.123.0FalseNoneNoneFalseNoneFalse2070.360
3598094130997NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes40 mm nominal dia Pipesm591.0591.011.0FalseNoneNoneFalseNoneFalse6501.00
3598095130997NonePWD SR 2023-24 V-2 Page No-122 It No-13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes50 mm nominal dia Pipesm902.25902.2532.0FalseNoneNoneFalseNoneFalse28872.00
3598096130997NonePWD SR 2023-24 V-2 Page No-136 It No-14.31Providing and fixing 600x450 mm bevelLed edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos.1511.581511.581.0FalseNoneNoneFalseNoneFalse1511.580
3598097130997NonePWD SR 2023-24 V-2 Page No-118 It No-13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameterNos.345.68345.681.0FalseNoneNoneFalseNoneFalse345.680
3598098130997NonePWD SR 2023-24 V-2 Page No-135 It No-14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Nos.6891.316891.311.0FalseNoneNoneFalseNoneFalse6891.310
3598099130997NonePWD SR 2023-24 V-2 Page No-119 It No-13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Nos.768.18768.181.0FalseNoneNoneFalseNoneFalse768.180
3598100130997NonePWD SR 2023-24 V-2 Page No-119 It No-13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr11.2611.261000.0FalseNoneNoneFalseNoneFalse11260.00
3598101130997NonePWD SR 2023-24 V-2 Page No-121 It No-13.26Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g.Nos.123.9123.95.0FalseNoneNoneFalseNoneFalse619.50
3598102130997NonePWD SR 2023-24 V-2 Page No-117 It No-13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal boreNos.415.46415.461.0FalseNoneNoneFalseNoneFalse415.460
3598103130997NonePWD SR 2023-24 V-2 Page No-118 It No-13.6.3.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore HorizontalNos.1201.331201.333.0FalseNoneNoneFalseNoneFalse3603.990
3598104130997NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.5Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 40 mm dia GM (Copper alloy) Gate valvesNos.1877.081877.0810.0FalseNoneNoneFalseNoneFalse18770.80
3598105130997NonePWD SR 2023-24 V-2 Page No-133 It No-11.15.6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark.For 50 mm dia GM (Copper alloy) Gate valvesNos.2112.342112.341.0FalseNoneNoneFalseNoneFalse2112.340
3598106130997NonePWD SR 2023-24 V-2 Page No-86 It No-7.5.1Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completeFor DI/CI puddle flanges of 80mm dia.Nos.1957.621957.621.0FalseNoneNoneFalseNoneFalse1957.620
3598107130997NonePWD SR 2023-24 V-2 Page No-123 It No-13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.Nos.387.8387.810.0FalseNoneNoneFalseNoneFalse3878.00
3598108130997NonePWD SR Old Sr 2018- 19 It No-11.37KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded nonmodular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4Nos.18749.7818749.782.0FalseNoneNoneFalseNoneFalse37499.560
3598109130997NonePWD SR 2023-24 V-2 Page No-126 It No-13.53Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Nos.6990.436990.432.0FalseNoneNoneFalseNoneFalse13980.860
3598110130997NonePWD SR 2023-24 V-2 Page No-124 It No-13.39Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.Nos.3197.853197.854.0FalseNoneNoneFalseNoneFalse12791.40
3598111130997NonePWD SR 2023-24 Volume 6 It No-2.2.1NQ ELECTRICAL POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Short point upto 3 mts from tapping point to out let via switch boxPoint317.42317.423.0FalseNoneNoneFalseNoneFalse952.260
3598112130997NonePWD SR 2023-24 Volume 6 It No-2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A MaterialsMedium point above 3 mts upto 6mts from tapping point to outlet via switch boxPoint447.22447.2213.0FalseNoneNoneFalseNoneFalse5813.860
3598113130997NonePWD SR 2023-24 Volume 6 It No-2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Long point above 6 mts upto 10 mts from tapping point to outlet via switch boxPoint654.9654.92.0FalseNoneNoneFalseNoneFalse1309.80
3598114130997NonePWD SR 2023-24 Volume 6 It No-2.2.4POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.point wiring using class A Materials Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switchesPoint798.86798.861.0FalseNoneNoneFalseNoneFalse798.860
3598115130997NonePWD SR 2023-24 Volume 6 It No-3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1 - 2 WayEach121.54121.541.0FalseNoneNoneFalseNoneFalse121.540
3598116130997NonePWD SR 2023-24 Volume 6 It No-3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.3 WayEach146.32146.321.0FalseNoneNoneFalseNoneFalse146.320
3598117130997NonePWD SR 2023-24 Volume 6 It No-3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4 - 5WayEach161.66161.661.0FalseNoneNoneFalseNoneFalse161.660
3598118130997NonePWD SR 2023-24 Volume 6 It No-3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6 WayEach204.14204.141.0FalseNoneNoneFalseNoneFalse204.140
3598119130997NonePWD SR 2023-24 Volume 6 It No-3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 WayEach258.42258.421.0FalseNoneNoneFalseNoneFalse258.420
3598120130997NonePWD SR 2023-24 Volume 6 It No-3.4.1Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall1 - 2 WayEach162.84162.844.0FalseNoneNoneFalseNoneFalse651.360
3598121130997NonePWD SR 2023-24 Volume 6 It No-3.4.2Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall3 WayEach187.62187.6210.0FalseNoneNoneFalseNoneFalse1876.20
3598122130997NonePWD SR 2023-24 Volume 6 It No-3.4.3Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall4 - 5WayEach208.86208.864.0FalseNoneNoneFalseNoneFalse835.440
3598123130997NonePWD SR 2023-24 Volume 6 It No-3.4.4Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall6 WayEach259.6259.65.0FalseNoneNoneFalseNoneFalse1298.00
3598124130997NonePWD SR 2023-24 Volume 6 It No-3.4.5Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall8 WayEach307.98307.982.0FalseNoneNoneFalseNoneFalse615.960
3598125130997NonePWD SR 2023-24 Volume 6 It No-3.4.6Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick / stone / cc wall10 - 12 WayEach376.42376.422.0FalseNoneNoneFalseNoneFalse752.840
3598126130997NonePWD SR 2023-24 Volume 6 It No-3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box1 to 2 ModuleEach161.66161.665.0FalseNoneNoneFalseNoneFalse808.30
3598127130997NonePWD SR 2023-24 Volume 6 It No-3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box3 ModuleEach189.98189.9811.0FalseNoneNoneFalseNoneFalse2089.780
3598128130997NonePWD SR 2023-24 Volume 6 It No-3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box4 ModuleEach206.5206.55.0FalseNoneNoneFalseNoneFalse1032.50
3598129130997NonePWD SR 2023-24 Volume 6 It No-3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box6 ModuleEach276.12276.126.0FalseNoneNoneFalseNoneFalse1656.720
3598130130997NonePWD SR 2023-24 Volume 6 It No-3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box8 ModuleEach335.12335.123.0FalseNoneNoneFalseNoneFalse1005.360
3598131130997NonePWD SR 2023-24 Volume 6 It No-3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal box10/12ModuleEach405.92405.922.0FalseNoneNoneFalseNoneFalse811.840
3598132130997NonePWD SR 2023-24 Volume 6 It No-3.6.1Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps one way switchEach120.36120.3636.0FalseNoneNoneFalseNoneFalse4332.960
3598133130997NonePWD SR 2023-24 Volume 6 It No-3.6.2Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 amps two way switchEach195.88195.886.0FalseNoneNoneFalseNoneFalse1175.280
3598134130997NonePWD SR 2023-24 Volume 6 It No-3.6.3Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 12936 Amps 3 way socketsEach201.78201.7814.0FalseNoneNoneFalseNoneFalse2824.920
3598135130997NonePWD SR 2023-24 Volume 6 It No-3.6.4Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293stepped fan Regulator'sEach421.26421.263.0FalseNoneNoneFalseNoneFalse1263.780
3598136130997NonePWD SR 2023-24 Volume 6 It No-3.6.10Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6/16 Amps universal socketsEach278.48278.485.0FalseNoneNoneFalseNoneFalse1392.40
3598137130997NonePWD SR 2023-24 Volume 6 It No-3.6.7Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switchEach212.4212.45.0FalseNoneNoneFalseNoneFalse1062.00
3598138130997NonePWD SR 2023-24 Volume 6 It No-3.6.9Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switchEach384.68384.681.0FalseNoneNoneFalseNoneFalse384.680
3598139130997NonePWD SR 2023-24 Volume 6 It No-3.6.8Supplying and fixing of modular switch / socket / stepped electronic fan regulator's / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell pushEach208.86208.861.0FalseNoneNoneFalseNoneFalse208.860
3598140130997NonePWD SR 2023-24 Volume 6 It No-12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Ding Donng bellEach290.28290.281.0FalseNoneNoneFalseNoneFalse290.280
3598141130997NonePWD SR 2023-24 Volume 6 It No-13.12Extra length of GI pipe of class B 19mm dia for down rod.Each232.46232.463.0FalseNoneNoneFalseNoneFalse697.380
3598142130997NonePWD SR 2023-24 Volume 6 It No-1.13Supply and fixing one metal Fan box with round hookEach138.06138.063.0FalseNoneNoneFalseNoneFalse414.180
3598143130997NonePWD SR 2023-24 Volume 6 It No-1.2.1Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 20 mm dia 2mm thickm77.8877.88145.0FalseNoneNoneFalseNoneFalse11292.60
3598144130997NonePWD SR 2023-24 Volume 6 It No-1.2.2Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary25 mm dia 2mm thickm92.0492.04185.0FalseNoneNoneFalseNoneFalse17027.40
3598145130997NonePWD SR 2023-24 Volume 6 It No-1.2.3Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends / metal / PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary32 mm dia 2.5mm thickm121.54121.5430.0FalseNoneNoneFalseNoneFalse3646.20
3598146130997NonePWD SR 2023-24 Volume 6 It No-1.3.1Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 20 mm dia 2mm thickm80.2480.2430.0FalseNoneNoneFalseNoneFalse2407.20
3598147130997NonePWD SR 2023-24 Volume 6 It No-1.3.2Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thickm93.2293.2235.0FalseNoneNoneFalseNoneFalse3262.70
3598148130997NonePWD SR 2023-24 Volume 6 It No-1.3.3Groove Cutting in WallSupplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thickm116.82116.825.0FalseNoneNoneFalseNoneFalse584.10
3598149130997NonePWD SR 2023-24 Volume 6 It No-1.5.1Supplying and fixing PVC/metal conduit deep junction box . 19/20mm deep junction boxEach57.8257.8215.0FalseNoneNoneFalseNoneFalse867.30
3598150130997NonePWD SR 2023-24 Volume 6 It No-1.5.2Supplying and fixing PVC/metal conduit deep junction box . 25mm deep junction boxEach66.0866.0820.0FalseNoneNoneFalseNoneFalse1321.60
3598151130997NonePWD SR 2023-24 Volume 6 It No-1.5.3Supplying and fixing PVC/metal conduit deep junction box .32mm deep junction boxEach71.9871.982.0FalseNoneNoneFalseNoneFalse143.960
3598152130997NonePWD SR 2023-24 Volume 6 It No-2.3.2WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments.1.5 Sq.mmm30.6830.68265.0FalseNoneNoneFalseNoneFalse8130.20
3598153130997NonePWD SR 2023-24 Volume 6 It No-2.3.3WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm49.5649.56320.0FalseNoneNoneFalseNoneFalse15859.20
3598154130997NonePWD SR 2023-24 Volume 6 It No-2.3.4WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 2.5 sq.mmm74.3474.34220.0FalseNoneNoneFalseNoneFalse16354.80
3598155130997NonePWD SR 2023-24 Volume 6 It No-2.3.5WIRING FOR Lighting/Power Circuits FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS -694:1990 & cofirming to Latest amendments. 6sq.mmm108.56108.5660.0FalseNoneNoneFalseNoneFalse6513.60
3598156130997NoneMR 1Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mmEach3.543.5440.0FalseNoneNoneFalseNoneFalse141.60
3598157130997NoneMR 2Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mmEach4.724.7260.0FalseNoneNoneFalseNoneFalse283.20
3598158130997NoneMR 3Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mmEach8.268.2616.0FalseNoneNoneFalseNoneFalse132.160
3598159130997NoneMR 4Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mmEach8.268.264.0FalseNoneNoneFalseNoneFalse33.040
3598160130997NonePWD SR 2023-24 Volume 6 It No-5.19.6MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way SP & NEach1798.321798.321.0FalseNoneNoneFalseNoneFalse1798.320
3598161130997NonePWD SR 2023-24 Volume 6 It No-5.19.9MCB DB & CABLE TRAY Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single/ DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP & NEach2748.222748.221.0FalseNoneNoneFalseNoneFalse2748.220
3598162130997NonePWD SR 2023-24 Volume 6 It No-5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SPEach489.7489.712.0FalseNoneNoneFalseNoneFalse5876.40
3598163130997NonePWD SR 2023-24 Volume 6 It No-5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DPEach1250.81250.82.0FalseNoneNoneFalseNoneFalse2501.60
3598164130997NonePWD SR 2023-24 Volume 6 It No-5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPNEach3643.843643.841.0FalseNoneNoneFalseNoneFalse3643.840
3598165130997NonePWD SR 2023-24 Volume 6 It No-12.3.2ELECTRICAL FIXTURES Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 WEach814.2814.24.0FalseNoneNoneFalseNoneFalse3256.80
3598166130997NonePWD SR 2023-24 Volume 6 It No-11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2Years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1562.321562.328.0FalseNoneNoneFalseNoneFalse12498.560
3598167130997NoneMR 5Supply and fixing of 12W LED retro fit lamp with holderEach531.0531.09.0FalseNoneNoneFalseNoneFalse4779.00
3598168130997NoneMR 6Supply and fixing of 18W LED Bulk Head light FixtureEach1947.01947.03.0FalseNoneNoneFalseNoneFalse5841.00
3598169130997NonePWD SR 2023-24 Volume 6 It No-6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1760.561760.561.0FalseNoneNoneFalseNoneFalse1760.560
3598170130997NonePWD SR 2023-24 Volume 6 It No-6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation Resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm)Each3158.863158.863.0FalseNoneNoneFalseNoneFalse9476.580
3598171130997NonePWD SR 2023-24 Volume 6 It No-13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each143.96143.9612.0FalseNoneNoneFalseNoneFalse1727.520
3598172130997NonePWD SR 2023-24 Volume 6 It No-13.1Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each201.78201.783.0FalseNoneNoneFalseNoneFalse605.340
3598173130997NonePWD SR 2023-24 Volume 6 It No-13.13Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each580.56580.561.0FalseNoneNoneFalseNoneFalse580.560
3598174130997NonePWD SR 2023-24 Volume 6 It No-12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each4141.84141.82.0FalseNoneNoneFalseNoneFalse8283.60
3598175130997NonePWD SR 2023-24 Volume 6 It No-12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25X3mm GI stripm96.7696.7630.0FalseNoneNoneFalseNoneFalse2902.80
3598176130997NonePWD SR 2023-24 Volume 6 It No-12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600x3mm GI PlateEach1032.51032.52.0FalseNoneNoneFalseNoneFalse2065.00
3598177130997NoneMR 7Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wirem28.3228.3280.0FalseNoneNoneFalseNoneFalse2265.60
3598178130997Nonedata ratePreparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting, HVAC, Lift Furnishing ,CCTV, networking system, UPS system, Nurse call system working drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - - - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.Job260945.0260945.01.0FalseNoneNoneFalseNoneFalse260945.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17218072440000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17218072440000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17218072440000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17218072440000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17218072440000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17218072900000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17218072960000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs.None
17218073020000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17218073080000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17218073140000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17218073200000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17218073250000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17218073310000NoneNoneELIGIBILITYAll the formats prescribed in the bid documents shall be filled in complete manner. (section 2 & 3 of the bid document) and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purpose.None
17218073400000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bid.None
17218073460000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17218073520000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract Help Desk for more assistance Phone: 080-25501216/ 25501227)None
17218073570000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoide damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17218073630000NoneNoneELIGIBILITYMaterials like, steel(primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17218073700000NoneNoneELIGIBILITYSpecial Instructions to tenderers - asper bid document (F. Special Conditions of Contract Clause-6)None
17218073780000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17218073840000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21, 2021-22, 2022-23 & 2023-24.None
17218073890000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within weeks time from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
17218073940000NoneNoneELIGIBILITYTenderer should have latest GST registration & upload latest GST/VAT clearance certificate in their nameNone
17218074010000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be Inclusive of GSTNone
17218074070000NoneNoneELIGIBILITYThe contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2aTo qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.1402.20 LakhPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause ITT 3.2bTo qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24)The tenderer should have been Satisfactorily completed at least one Similar work of value not less than Rs.350.55 Lakhs as prime contractor.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(c): To qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24).Executed in any one financial year,the following minimum quantities of work Sl.No Description of key items of works 1. Earthwork Excavation in all kinds of soil 2450.00 Cum 2.PCC & RCC 12808.00 Cum 3. Steel Reinforcement for RCC work (TMT Steel) 77.73 Tonne 4.BBM/Concrete Blocks 536.00 Cum. 5. Plastering 7053.00 Sqm 6. Painting (OBD/Textured Painting/Wood and Metal Painting) 10863.00 Sqm 7. Flooring (Vitrified/Granite/Ceramic) 1634.00 Sqm 8. MS Grill 2286.00 Kgs Note:The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2d The tenderer or his identified sub contractor should possess required valid electrical license issued by KPWD,Government electrical Inspectorate for executing building electrification works and should have executed similar Building electrical works totaling to Rs.55.99 Lakh in any one year Note.The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government,Semi Government,Government undertaking,autonomous bodies of Government will be considered, for the clause 3.2d.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(e):The Tenderer or his identified sub-contractor should possess valid license issued by BWSSB/KUWS&DB for executing water supply/sanitary engineering works and should have executed similar building water supply/sanitary engineering works totaling to Rs.12.68 Lakhs in any one year Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (e).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClass - I PWD Registered Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneClause ITT 3.3(a) Equipment capacity: Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50%can be deployed on ease/hire basis for all works provided,the relevant documents (commitment agreements etc) for availability for this work are furnished SlNo. Description of Key items of Works. Quantity1. Excavator/JCB 1No 2. Transit Mixer/Concrete Mixer 1 No 3. Needle vibrator with size not less than 20mm 1 No 4.Tipper 1 No 5.Generator 250 KVA 1 No 6. Truck Mounted Water Tanker 1 No Note: All Machineries purchased during last five years only should be used and will be considered for evaluation.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tax Invoice/Agreements from the supplier
NoneNoneNoneNoneClause ITT 3.6 Tenderers who meet the above specified minimum qualifying criteria,will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity(AxNx1.5-B)where A Maximum value of civil engineering works executed in any one year during the last five years i.e (2019-20-2023-24)(updated to 2024-25 price level)taking into account the completed as well as works in progress .N Number of years prescribed for completion of the works for which tender are invited. B Value at 2024-25 price level, of existing commitments of and ongoing works to be Completed during the next 11 months.Note:(1)The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent(2)Tenderer shall submit the list of Ongoing works duly certified by the Auditor/Chartered Accountant.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by the officer not lessthan the rank of Executive Engineer Ongoing commitments and Bids submitted for the works
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work 1) Site Engineer (Civil) B.E. Civil with minimum experience of 7 years in the Construction of buildings 1 (One) 2) Site Engineer (Electrical Engineer) B.E. Electrical with minimum experience of 5 years in the Construction of buildings 1 (One) Note: 1) The tenderer shall submit list and photo identity proof such as Aadhar Card/Voter ID/Employee ID/Pass port/Driving License etc., for the key personnel such as project manager/site engineer to be deployed at each of the worksite. 2) The key personnel deployed at the site for this work should be working for a minimum period of one year with the tenderers and experience certificate has to be furnished in this regard.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates
NoneNoneNoneNoneClause ITT 3.3(b):Liquid assets and/or availability of credit facilities of not less than Rs.280.44 Lakh (Credit lines/letter of credit/certificates from banks for meeting the fund requirement etc.,)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
PWD Registration CertificateTrueTechnical Bid
GST CertificateTrueTechnical Bid
ESI & PF CertificateTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1721808069000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Health and Family Welfare Department, Engineering Wing, 3rd Floor Arogya Soudha 1st Cross Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone