1721457135000 | 0 | None | None | Dam and Allied works | Providing and laying chainlink fencing along the boundry at the downstream side of the dam, Providing and fixing electrification works of dam, construction of electrical control room and construction of drain along the approach road of Kiniye dam in Kiniye village. | 31189243.27 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3561264 | 129019 | None | code01 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 139.24 | 139.24 | 28.23 | False | None | None | False | None | False | 3930.7452 | 0 | 3561265 | 129019 | None | code02 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter includingdressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage ofmachinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 112.1 | 112.1 | 8.47 | False | None | None | False | None | False | 949.487 | 0 | 3561266 | 129019 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 120.36 | 120.36 | 278.09 | False | None | None | False | None | False | 33470.9124 | 0 | 3561267 | 129019 | None | code04 | Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 285.56 | 285.56 | 1036.8 | False | None | None | False | None | False | 296068.608 | 0 | 3561268 | 129019 | None | code05 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 428.34 | 428.34 | 2.21 | False | None | None | False | None | False | 946.6314 | 0 | 3561269 | 129019 | None | code06 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock)in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances requiredto complete the work. 1.6.1 In all kinds of soils. Depth upto 1.50m | Cum | 571.12 | 571.12 | 777.59 | False | None | None | False | None | False | 444097.2008 | 0 | 3561270 | 129019 | None | code07 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 7067.02 | 7067.02 | 26.0 | False | None | None | False | None | False | 183742.52 | 0 | 3561271 | 129019 | None | code08 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 7279.03 | 7279.03 | 115.2 | False | None | None | False | None | False | 838544.256 | 0 | 3561272 | 129019 | None | code09 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Footings) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 8012.15 | 8012.15 | 4.48 | False | None | None | False | None | False | 35894.432 | 0 | 3561273 | 129019 | None | code10 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 313.88 | 313.88 | 22.18 | False | None | None | False | None | False | 6961.8584 | 0 | 3561274 | 129019 | None | code11 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 559.32 | 559.32 | 6.16 | False | None | None | False | None | False | 3445.4112 | 0 | 3561275 | 129019 | None | code12 | Supplying at site angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Kg | 133.34 | 133.34 | 43305.29 | False | None | None | False | None | False | 5774327.3686 | 0 | 3561276 | 129019 | None | code13 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Kg | 1053.74 | 1053.74 | 3205.0 | False | None | None | False | None | False | 3377236.7 | 0 | 3561277 | 129019 | None | code14 | Supplying and fixing of Galvanised steel barbed wire with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Quintal | 7670.0 | 7670.0 | 14.0 | False | None | None | False | None | False | 107380.0 | 0 | 3561278 | 129019 | None | code15 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.a. Buildings with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Tonne | 105559.26 | 105559.26 | 3.4 | False | None | None | False | None | False | 358901.484 | 0 | 3561279 | 129019 | None | code16 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification All other type of structures with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Tonne | 93232.98 | 93232.98 | 23.52 | False | None | None | False | None | False | 2192839.6896 | 0 | 3561280 | 129019 | None | code17 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Footing with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 8449.27 | 8449.27 | 34.83 | False | None | None | False | None | False | 294288.0741 | 0 | 3561281 | 129019 | None | code18 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 8058.03 | 8058.03 | 62.99 | False | None | None | False | None | False | 507575.3097 | 0 | 3561282 | 129019 | None | code19 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 12683.94 | 12683.94 | 0.59 | False | None | None | False | None | False | 7483.5246 | 0 | 3561283 | 129019 | None | code20 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( for Plinth beams ) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 11191.71 | 11191.71 | 1.76 | False | None | None | False | None | False | 19697.4096 | 0 | 3561284 | 129019 | None | code21 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 13299.78 | 13299.78 | 2.48 | False | None | None | False | None | False | 32983.4544 | 0 | 3561285 | 129019 | None | code22 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( For Beams & Lintels ) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 12517.44 | 12517.44 | 2.77 | False | None | None | False | None | False | 34673.3088 | 0 | 3561286 | 129019 | None | code23 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Roof Slab) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 11735.1 | 11735.1 | 3.54 | False | None | None | False | None | False | 41542.254 | 0 | 3561287 | 129019 | None | code24 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( For Chejjas, Canopy & Other Architectural projections of minor sections ) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 11343.93 | 11343.93 | 0.32 | False | None | None | False | None | False | 3630.0576 | 0 | 3561288 | 129019 | None | code25 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 7834.2 | 7834.2 | 436.8 | False | None | None | False | None | False | 3421978.56 | 0 | 3561289 | 129019 | None | code26 | Fabricating,supplying and erection of...ms long hot dip Galvanized Conical hot dip Pole with BSEN10025 grade S355JO steel plate for shaft,IS2062 for base plate with door opening arrangements,including suitable boards,Bake lites heet and MC Bsas per IS specifications suitable to with stand the wind speed of 47m/s for.......m Pole in single section and single joint welded as per IS9595/IS10178AW Shaving dimensions bottom.....mm,top...mm with 3mmthick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65 micron as per ASTM-A123 and 153etc.,(excluding foundation) as per drawing appended.9 m - Top 70 mm and Bottom 155 mm dia with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 23010.0 | 23010.0 | 58.0 | False | None | None | False | None | False | 1334580.0 | 0 | 3561290 | 129019 | None | code27 | Supply of LED Street light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonate material,delivering superior light output Rated life Burning Hrs50000hr at Lumen Supply of LED Street light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonate material,delivering superior light output Rated life Burning Hrs50000hr at Lumen Maintenance of 70percentage,maximum light intensity should bebetween 60 degrees to 70degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminairegreater thanIK08.PowerFactorgreater than0.9withmains,Surge Protection Min5KV along with Over voltage/Overload,shortcircuit/misswiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm.Universal Voltage driver to operate wide voltage range from 100V to 270V50/60Hzapplication.Compliance to IS10322/IEC60598,LM79&LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimaltools.LEDLight fixture with........W System Power consumption.LED Efficiencygreater than1301m/w,nominalCRI greater than 75.Luminaire manufacturer should have in house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO9001:2008.Housing with supplier word mark/name shall be Engraved/Embossing on the die cast housing/Bodypart.Warranty of 2 Years against any manufacturing defect working understand ardelectrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source. 40W with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 11870.8 | 11870.8 | 58.0 | False | None | None | False | None | False | 688506.4 | 0 | 3561291 | 129019 | None | code28 | supply and fixing of reflecto parachut mega module ,out door type envoronmentle friendly decorative in direct luminar intigral .intigrated with 50w led and for muinting on 200mm dia pole with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 45076.0 | 45076.0 | 50.0 | False | None | None | False | None | False | 2253800.0 | 0 | 3561292 | 129019 | None | code29 | Supply and erection of 14 Feet Height Street Light Pole 14 Feet Height Street Light Pole on suitable cement concrete foundation with 2.5 Feet height dia 95 mm cast iron decorative round pedestal as per design weighing not less than 37Kgs, the pedestal shall be fitted with Class 'C' G.I.Pipe 7 Feet height 75 mm outer dia and 7 feet height top piece outer dia of 65 mm fixed by measure of threading/welding/coupling complete. (excluding foundation). with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 24308.0 | 24308.0 | 50.0 | False | None | None | False | None | False | 1215400.0 | 0 | 3561293 | 129019 | None | code30 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130 1984 and Virgin PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS 694 199 3C x 2.5 Sqmm with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Mtr | 133.34 | 133.34 | 1550.0 | False | None | None | False | None | False | 206677.0 | 0 | 3561294 | 129019 | None | code31 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. - 14 SWG | Sq CM | 0.59 | 0.59 | 172000.0 | False | None | None | False | None | False | 101480.0 | 0 | 3561295 | 129019 | None | code32 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. - 50 x 50 x 6 mm with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Mtr | 466.1 | 466.1 | 63.0 | False | None | None | False | None | False | 29364.3 | 0 | 3561296 | 129019 | None | code33 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flatframe work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete - 100 A 4 x 30 x 6 mm Aluminium Strips with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Mtr | 2908.7 | 2908.7 | 8.0 | False | None | None | False | None | False | 23269.6 | 0 | 3561297 | 129019 | None | code34 | Supplying and fixing of LED type panelboard indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge . | Each | 607.7 | 607.7 | 250.0 | False | None | None | False | None | False | 151925.0 | 0 | 3561298 | 129019 | None | code35 | Wiring forl ighting/power circuit using one of FRLS PVC insulated 1100V grade,multistrand copperwire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 - 2.5 mm2 with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Mtr | 49.56 | 49.56 | 520.0 | False | None | None | False | None | False | 25771.2 | 0 | 3561299 | 129019 | None | code36 | Wiring forl ighting/power circuit using one of FRLS PVC insulated 1100V grade,multistrand copperwire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 - 4 mm2 with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Mtr | 74.34 | 74.34 | 250.0 | False | None | None | False | None | False | 18585.0 | 0 | 3561300 | 129019 | None | code37 | Wiring forl ighting/power circuit using one of FRLS PVC insulated 1100V grade,multistrand copperwire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 - 6 mm2 with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Mtr | 108.56 | 108.56 | 250.0 | False | None | None | False | None | False | 27140.0 | 0 | 3561301 | 129019 | None | code38 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing material sand 'C' Type curve,indicator ON/OFF,energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. - 6-32 A SP with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 489.7 | 489.7 | 131.0 | False | None | None | False | None | False | 64150.7 | 0 | 3561302 | 129019 | None | code39 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing material sand 'C' Type curve,indicator ON/OFF,energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. - - 50-63 A TPN with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 3643.84 | 3643.84 | 5.0 | False | None | None | False | None | False | 18219.2 | 0 | 3561303 | 129019 | None | code40 | Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers.with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 5714.74 | 5714.74 | 5.0 | False | None | None | False | None | False | 28573.7 | 0 | 3561304 | 129019 | None | code41 | Supply and fixing of 3 pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947 - 60 A with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 7021.0 | 7021.0 | 5.0 | False | None | None | False | None | False | 35105.0 | 0 | 3561305 | 129019 | None | code42 | Supplying and fixing HRC fuse units base on existing switch /panel board. - 100 to 300A with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 1084.42 | 1084.42 | 15.0 | False | None | None | False | None | False | 16266.3 | 0 | 3561306 | 129019 | None | code43 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Job | 4141.8 | 4141.8 | 10.0 | False | None | None | False | None | False | 41418.0 | 0 | 3561307 | 129019 | None | code44 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Km | 167373.56 | 167373.56 | 2.3 | False | None | None | False | None | False | 384959.188 | 0 | 3561308 | 129019 | None | code45 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Km | 212215.92 | 212215.92 | 1.8 | False | None | None | False | None | False | 381988.656 | 0 | 3561309 | 129019 | None | code46 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff - LT Cable - 2.5 to 25 Sqmm with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Km | 24645.48 | 24645.48 | 2.16 | False | None | None | False | None | False | 53234.2368 | 0 | 3561310 | 129019 | None | code47 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 - HDPE Grade PE80-PN6.0, 63mm dia. with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Mtr | 223.02 | 223.02 | 2160.0 | False | None | None | False | None | False | 481723.2 | 0 | 3561311 | 129019 | None | code48 | Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014, 100 kVA, Aluminium Wdg, Star 2 (5 Star) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 261903.36 | 261903.36 | 1.0 | False | None | None | False | None | False | 261903.36 | 0 | 3561312 | 129019 | None | code49 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975,185 Sqmm, (51 GI Wires - 3.15 mm Dia) | Km | 1585345.34 | 1585345.34 | 0.2 | False | None | None | False | None | False | 317069.068 | 0 | 3561313 | 129019 | None | code50 | Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573,1343513 | Km | 2026.06 | 2026.06 | 4.0 | False | None | None | False | None | False | 8104.24 | 0 | 3561314 | 129019 | None | code51 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975185 Sqmm, 3.5 Core, (28 GI Strips - 4 x 0.8 mm) | Km | 815637.24 | 815637.24 | 0.1 | False | None | None | False | None | False | 81563.724 | 0 | 3561315 | 129019 | None | code52 | Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable,3.5 x 150/185 Sqmm | Kit | 566.4 | 566.4 | 4.0 | False | None | None | False | None | False | 2265.6 | 0 | 3561316 | 129019 | None | code53 | LT Distribution Box as per IS-13947 Part1&2LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) (Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Kit | 26769.48 | 26769.48 | 1.0 | False | None | None | False | None | False | 26769.48 | 0 | 3561317 | 129019 | None | code54 | Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 230100.0 | 230100.0 | 4.0 | False | None | None | False | None | False | 920400.0 | 0 | 3561318 | 129019 | None | code55 | Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 V 3 phase and wired after fixing to the existing wooden board for motor,Above 12.5 HP upto 25 HP with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 10341.52 | 10341.52 | 10.0 | False | None | None | False | None | False | 103415.2 | 0 | 3561319 | 129019 | None | code56 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.11 to 20 kVAR with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 405.92 | 405.92 | 4.0 | False | None | None | False | None | False | 1623.68 | 0 | 3561320 | 129019 | None | code57 | Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947.100 A with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 5313.54 | 5313.54 | 6.0 | False | None | None | False | None | False | 31881.24 | 0 | 3561321 | 129019 | None | code58 | Supplying and fixing HRC fuse units base on existing switch / panel board,32 to 63 A with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 261903.36 | 261903.36 | 6.0 | False | None | None | False | None | False | 1571420.16 | 0 | 3561322 | 129019 | None | code59 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.(120A) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 26643.22 | 26643.22 | 10.0 | False | None | None | False | None | False | 266432.2 | 0 | 3561323 | 129019 | None | code60 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 A DP with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 1300.36 | 1300.36 | 10.0 | False | None | None | False | None | False | 13003.6 | 0 | 3561324 | 129019 | None | code61 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 600 A 4 x 75 x 10 mm Aluminium Strips with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Mtr | 6637.5 | 6637.5 | 25.0 | False | None | None | False | None | False | 165937.5 | 0 | 3561325 | 129019 | None | code62 | Supply of LED Bollard light fitting of ...W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage Overload, short circuit/ misswiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322 IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition.8W 1 m Heightwith all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 5344.16 | 5344.16 | 60.0 | False | None | None | False | None | False | 320649.6 | 0 | 3561326 | 129019 | None | code63 | Supply and fixing of under water led lunair Gem rate for under water led light 3x3 watt with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 27671.0 | 27671.0 | 40.0 | False | None | None | False | None | False | 1106840.0 | 0 | 3561327 | 129019 | None | code64 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges completewith all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 9403.42 | 9403.42 | 15.97 | False | None | None | False | None | False | 150172.6174 | 0 | 3561328 | 129019 | None | code65 | Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 6160.78 | 6160.78 | 4.2 | False | None | None | False | None | False | 25875.276 | 0 | 3561329 | 129019 | None | code66 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 215.94 | 215.94 | 60.48 | False | None | None | False | None | False | 13060.0512 | 0 | 3561330 | 129019 | None | code67 | Providing & fixing of 2track x 2panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 6360.2 | 6360.2 | 2.88 | False | None | None | False | None | False | 18317.376 | 0 | 3561331 | 129019 | None | code68 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 300.9 | 300.9 | 83.16 | False | None | None | False | None | False | 25022.844 | 0 | 3561332 | 129019 | None | code69 | Providing 18 mm cement plaster in two coats under layer 12 mm thickcement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge . | Sqm | 454.3 | 454.3 | 150.12 | False | None | None | False | None | False | 68199.516 | 0 | 3561333 | 129019 | None | code70 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 1386.5 | 1386.5 | 26.76 | False | None | None | False | None | False | 37102.74 | 0 | 3561334 | 129019 | None | code71 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 186.44 | 186.44 | 83.16 | False | None | None | False | None | False | 15504.3504 | 0 | 3561335 | 129019 | None | code72 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 205.32 | 205.32 | 150.12 | False | None | None | False | None | False | 30822.6384 | 0 | 3561336 | 129019 | None | code73 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 164.02 | 164.02 | 7.08 | False | None | None | False | None | False | 1161.2616 | 0 |
|