1721472587000 | 0 | None | None | Dam and Allied works | Construction of Service Bridge on downstream side, Construction of RHS and LHS intake approach Channel, Construction of cross regulator cum escape, construction of site office and construction of main entrance gate of kiniye dam in kiniye village. | 32243740.04 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3567262 | 129404 | None | code01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter includingdressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage ofmachinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 112.1 | 112.1 | 43.2 | False | None | None | False | None | False | 4842.72 | 0 | 3567263 | 129404 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 120.36 | 120.36 | 4877.35 | False | None | None | False | None | False | 587037.846 | 0 | 3567264 | 129404 | None | code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 428.34 | 428.34 | 205.72 | False | None | None | False | None | False | 88118.1048 | 0 | 3567265 | 129404 | None | code04 | Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 m with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 501.5 | 501.5 | 49.19 | False | None | None | False | None | False | 24668.785 | 0 | 3567266 | 129404 | None | code05 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the in work ordinary/soft rock without blasting Depth exceeding 3m, but not exceeding 4.5m with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 546.34 | 546.34 | 533.37 | False | None | None | False | None | False | 291401.3658 | 0 | 3567267 | 129404 | None | code06 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 139.24 | 139.24 | 143.99 | False | None | None | False | None | False | 20049.1676 | 0 | 3567268 | 129404 | None | code07 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7067.02 | 7067.02 | 144.56 | False | None | None | False | None | False | 1021608.4112 | 0 | 3567269 | 129404 | None | code08 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates "For Form work 5% " with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 7420.37 | 7420.37 | 69.57 | False | None | None | False | None | False | 516235.1409 | 0 | 3567270 | 129404 | None | code09 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 7461.14 | 7461.14 | 38.3 | False | None | None | False | None | False | 285761.662 | 0 | 3567271 | 129404 | None | code10 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including cost of all materials, labor ,HOM,l & UL, curing with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge of the work. | Cum | 9719.42 | 9719.42 | 217.11 | False | None | None | False | None | False | 2110183.2762 | 0 | 3567272 | 129404 | None | code11 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Footings) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 8012.15 | 8012.15 | 14.32 | False | None | None | False | None | False | 114733.988 | 0 | 3567273 | 129404 | None | code12 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 9940.32 | 9940.32 | 28.77 | False | None | None | False | None | False | 285983.0064 | 0 | 3567274 | 129404 | None | code13 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 10093.25 | 10093.25 | 74.65 | False | None | None | False | None | False | 753461.1125 | 0 | 3567275 | 129404 | None | code14 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 10900.9 | 10900.9 | 88.83 | False | None | None | False | None | False | 968326.947 | 0 | 3567276 | 129404 | None | code15 | Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. (Batching Plant) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 16485.78 | 16485.78 | 1.07 | False | None | None | False | None | False | 17639.7846 | 0 | 3567277 | 129404 | None | code16 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 12683.94 | 12683.94 | 2.1 | False | None | None | False | None | False | 26636.274 | 0 | 3567278 | 129404 | None | code17 | Providing and laying in-situ vibrated M-15 grade cement concrete using 40 mm down approved, clean, hard, graded aggregates with placing and sinking plums of size 150 to 80 mm upto 15 percent for gravity type structures including cost of all materials, machinery, labour,cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing with all other ancillary operations complete. | Cum | 7307.74 | 7307.74 | 333.27 | False | None | None | False | None | False | 2435450.5098 | 0 | 3567279 | 129404 | None | code18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Super structure of Bridges with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Tonne | 101990.94 | 101990.94 | 29.53 | False | None | None | False | None | False | 3011792.4582 | 0 | 3567280 | 129404 | None | code19 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Super structure of Bridges with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Tonne | 102256.44 | 102256.44 | 9.18 | False | None | None | False | None | False | 938714.1192 | 0 | 3567281 | 129404 | None | code20 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Super structure of Bridges with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Tonne | 104833.56 | 104833.56 | 43.4 | False | None | None | False | None | False | 4549776.504 | 0 | 3567282 | 129404 | None | code21 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 8605.74 | 8605.74 | 542.48 | False | None | None | False | None | False | 4668441.8352 | 0 | 3567283 | 129404 | None | code22 | Providing weep holes in Brick masonary Plain Reinforced concrete abutment, wing wall return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V 20H towards drawing foce. Complete as per drawing and Technical Specifications 2706 and 2200.with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Rmtr | 162.84 | 162.84 | 143.5 | False | None | None | False | None | False | 23367.54 | 0 | 3567284 | 129404 | None | code23 | Providing and Filling in foundation with granite / trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 3164.76 | 3164.76 | 197.1 | False | None | None | False | None | False | 623774.196 | 0 | 3567285 | 129404 | None | code24 | Back filling behind abutment, wing wall and return wall complete including compaction as per drawing and Technical Specification Granular material 710.1.4.of IRC:78 &2200 with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 1378.24 | 1378.24 | 703.55 | False | None | None | False | None | False | 969660.752 | 0 | 3567286 | 129404 | None | code25 | PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification 2700 with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 8036.98 | 8036.98 | 5.78 | False | None | None | False | None | False | 46453.7444 | 0 | 3567287 | 129404 | None | code26 | Reinforced cement concrete M30 grade for approach slab including reinforcement and formwork complete as per drawing and Technical specification (Batching Plant) 1500 1600 1700 & 2704 with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 13965.3 | 13965.3 | 11.55 | False | None | None | False | None | False | 161299.215 | 0 | 3567288 | 129404 | None | code27 | Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications. (Batching Plant) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 16485.78 | 16485.78 | 13.32 | False | None | None | False | None | False | 219590.5896 | 0 | 3567289 | 129404 | None | code28 | Providing and laying of Filter media with granular materials/ stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.710.1.4.of IRC:78 and 2200 with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 3158.86 | 3158.86 | 25.48 | False | None | None | False | None | False | 80487.7528 | 0 | 3567290 | 129404 | None | code29 | Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification. Boulder Laid Dry Without Wire Crates.with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 1931.66 | 1931.66 | 96.9 | False | None | None | False | None | False | 187177.854 | 0 | 3567291 | 129404 | None | code30 | Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 7337.24 | 7337.24 | 58.14 | False | None | None | False | None | False | 426587.1336 | 0 | 3567292 | 129404 | None | code31 | Filler Joint Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Rmtr | 161.66 | 161.66 | 16.0 | False | None | None | False | None | False | 2586.56 | 0 | 3567293 | 129404 | None | code32 | Drainage Spouts using 100 mm GI pipe complete as per drawing and Technical specification 2705 with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Nos | 3859.78 | 3859.78 | 20.0 | False | None | None | False | None | False | 77195.6 | 0 | 3567294 | 129404 | None | code33 | Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Nos | 882.64 | 882.64 | 64.0 | False | None | None | False | None | False | 56488.96 | 0 | 3567295 | 129404 | None | code34 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 313.88 | 313.88 | 65.94 | False | None | None | False | None | False | 20697.2472 | 0 | 3567296 | 129404 | None | code35 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 559.32 | 559.32 | 1943.17 | False | None | None | False | None | False | 1086853.8444 | 0 | 3567297 | 129404 | None | code36 | Providing and filling Murrum / Gravely soil (CNS Soil ) for foundation or around pipes including cost of materials, machinery, labour, breaking clods, spreading in layers of 100 to 150 mm. watering, compaction by earth masters to achieve density control of not less than 90 percent etc., complete with lead and all lifts.with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 967.6 | 967.6 | 76.19 | False | None | None | False | None | False | 73721.444 | 0 | 3567298 | 129404 | None | code37 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Canal & Allied Works with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Tonne | 106211.8 | 106211.8 | 8.8 | False | None | None | False | None | False | 934663.84 | 0 | 3567299 | 129404 | None | code38 | Design, fabrication, supply, erection, testing and commissioning of fixed wheel type vertical lift gate ( with top seal ) consisting of skin plate, siffeners, horizontal and vertical girders, wheels, guide rollers, rubber seals with all accessories for canal escape / regulator vent including cost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, applying one coat of zinc rich epoxy primer and three coats of cold applied coal tar epoxy paint, seal fixing and all other ancillary operations complete as per specifications and approved drawings. with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Tonne | 208270.0 | 208270.0 | 1.02 | False | None | None | False | None | False | 212435.4 | 0 | 3567300 | 129404 | None | code39 | Design, fabrication, supply, erection, testing and commissioning of fixed wheel type vertical lift gate ( with top seal ) consisting of skin plate, siffeners, horizontal and vertical girders, wheels, guide rollers, rubber seals with all accessories for canal escape / regulator vent including cost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, applying one coat of zinc rich epoxy primer and three coats of cold applied coal tar epoxy paint, seal fixing and all other ancillary operations complete as per specifications and approved drawings. with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Tonne | 223020.0 | 223020.0 | 1.58 | False | None | None | False | None | False | 352371.6 | 0 | 3567301 | 129404 | None | code40 | Design, fabrication, supply, erection, testing and commissioning of fixed wheel type vertical lift gate ( with top seal ) consisting of skin plate, siffeners, horizontal and vertical girders, wheels, guide rollers, rubber seals with all accessories for canal escape / regulator vent including cost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, applying one coat of zinc rich epoxy primer and three coats of cold applied coal tar epoxy paint, seal fixing and all other ancillary operations complete as per specifications and approved drawings. with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Tonne | 56286.0 | 56286.0 | 2.6 | False | None | None | False | None | False | 146343.6 | 0 | 3567302 | 129404 | None | code41 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( for Plinth beams ) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 11191.71 | 11191.71 | 7.38 | False | None | None | False | None | False | 82594.8198 | 0 | 3567303 | 129404 | None | code42 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Columns) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 13299.78 | 13299.78 | 11.36 | False | None | None | False | None | False | 151085.5008 | 0 | 3567304 | 129404 | None | code43 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( For Beams & Lintels ) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 12517.44 | 12517.44 | 11.73 | False | None | None | False | None | False | 146829.5712 | 0 | 3567305 | 129404 | None | code44 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For Roof Slab) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 11735.1 | 11735.1 | 15.36 | False | None | None | False | None | False | 180251.136 | 0 | 3567306 | 129404 | None | code45 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 9403.42 | 9403.42 | 78.08 | False | None | None | False | None | False | 734219.0336 | 0 | 3567307 | 129404 | None | code46 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cementmortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery& other incidental charges with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 1151.68 | 1151.68 | 8.22 | False | None | None | False | None | False | 9466.8096 | 0 | 3567308 | 129404 | None | code47 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( For Chejjas, Canopy & Other Architectural projections of minor sections ) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 11343.93 | 11343.93 | 1.67 | False | None | None | False | None | False | 18944.3631 | 0 | 3567309 | 129404 | None | code48 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges cwith all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 116601.7 | 116601.7 | 0.21 | False | None | None | False | None | False | 24486.357 | 0 | 3567310 | 129404 | None | code49 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) | Sqm | 8783.92 | 8783.92 | 10.08 | False | None | None | False | None | False | 88541.9136 | 0 | 3567311 | 129404 | None | code50 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Nos | 1198.88 | 1198.88 | 4.0 | False | None | None | False | None | False | 4795.52 | 0 | 3567312 | 129404 | None | code51 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Kg | 215.94 | 215.94 | 332.64 | False | None | None | False | None | False | 71830.2816 | 0 | 3567313 | 129404 | None | code52 | Providing & fixing of 2 track x 2 panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall
not be made) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 6360.2 | 6360.2 | 15.84 | False | None | None | False | None | False | 100745.568 | 0 | 3567314 | 129404 | None | code53 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 300.9 | 300.9 | 280.21 | False | None | None | False | None | False | 84315.189 | 0 | 3567315 | 129404 | None | code54 | Providing 18 mm cement plaster in two coats under layer 12 mm thickcement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 454.3 | 454.3 | 435.57 | False | None | None | False | None | False | 197879.451 | 0 | 3567316 | 129404 | None | code55 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification (a) Buildings with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Tonne | 105559.26 | 105559.26 | 5.95 | False | None | None | False | None | False | 628077.597 | 0 | 3567317 | 129404 | None | code56 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 1386.5 | 1386.5 | 113.62 | False | None | None | False | None | False | 157534.13 | 0 | 3567318 | 129404 | None | code57 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree
angle with 10 years life) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 186.44 | 186.44 | 280.21 | False | None | None | False | None | False | 52242.3524 | 0 | 3567319 | 129404 | None | code58 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 205.32 | 205.32 | 435.57 | False | None | None | False | None | False | 89431.2324 | 0 | 3567320 | 129404 | None | code59 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 62.54 | 62.54 | 25.2 | False | None | None | False | None | False | 1576.008 | 0 | 3567321 | 129404 | None | code60 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 162.84 | 162.84 | 25.2 | False | None | None | False | None | False | 4103.568 | 0 | 3567322 | 129404 | None | code61 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 164.02 | 164.02 | 37.28 | False | None | None | False | None | False | 6114.6656 | 0 | 3567323 | 129404 | None | code62 | Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. 125x70x4 mm (ordinary type ) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 200.6 | 200.6 | 24.0 | False | None | None | False | None | False | 4814.4 | 0 | 3567324 | 129404 | None | code63 | Providing and fixing Hold fasts M.S. for doors with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 59.0 | 59.0 | 48.0 | False | None | None | False | None | False | 2832.0 | 0 | 3567325 | 129404 | None | code64 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125mm with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 51.92 | 51.92 | 16.0 | False | None | None | False | None | False | 830.72 | 0 | 3567326 | 129404 | None | code65 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 1241.36 | 1241.36 | 16.0 | False | None | None | False | None | False | 19861.76 | 0 | 3567327 | 129404 | None | code66 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Nos | 153.4 | 153.4 | 8.0 | False | None | None | False | None | False | 1227.2 | 0 | 3567328 | 129404 | None | code67 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Nos | 141.6 | 141.6 | 4.0 | False | None | None | False | None | False | 566.4 | 0 | 3567329 | 129404 | None | code68 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 1460.84 | 1460.84 | 10.31 | False | None | None | False | None | False | 15061.2604 | 0 | 3567330 | 129404 | None | code69 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 375.24 | 375.24 | 24.0 | False | None | None | False | None | False | 9005.76 | 0 | 3567331 | 129404 | None | code70 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with one side prelam with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 2407.2 | 2407.2 | 7.56 | False | None | None | False | None | False | 18198.432 | 0 | 3567332 | 129404 | None | code71 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete | Sqm | 1049.02 | 1049.02 | 9.25 | False | None | None | False | None | False | 9703.435 | 0 | 3567333 | 129404 | None | code72 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.including pointing the joints with white cement and matching pigments with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 1709.82 | 1709.82 | 42.48 | False | None | None | False | None | False | 72633.1536 | 0 | 3567334 | 129404 | None | code73 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 5763.12 | 5763.12 | 3.0 | False | None | None | False | None | False | 17289.36 | 0 | 3567335 | 129404 | None | code74 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 5255.72 | 5255.72 | 2.0 | False | None | None | False | None | False | 10511.44 | 0 | 3567336 | 129404 | None | code75 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 3636.76 | 3636.76 | 2.0 | False | None | None | False | None | False | 7273.52 | 0 | 3567337 | 129404 | None | code76 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete 40 mm dia with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Rmtr | 108.56 | 108.56 | 10.0 | False | None | None | False | None | False | 1085.6 | 0 | 3567338 | 129404 | None | code77 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Rmtr | 164.02 | 164.02 | 40.0 | False | None | None | False | None | False | 6560.8 | 0 | 3567339 | 129404 | None | code78 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Sin with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Rmtr | 232.46 | 232.46 | 30.0 | False | None | None | False | None | False | 6973.8 | 0 | 3567340 | 129404 | None | code79 | PVC pipe - OD 110mm and 6 Kg/sqcm - (Shaft Drainage) with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Rmtr | 300.9 | 300.9 | 12.0 | False | None | None | False | None | False | 3610.8 | 0 | 3567341 | 129404 | None | code80 | C.P. Brass stop cock (concealed) 15 mm with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Each | 619.5 | 619.5 | 1.0 | False | None | None | False | None | False | 619.5 | 0 | 3567342 | 129404 | None | code81 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 15 mm nominal dia pipes with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Rmtr | 364.62 | 364.62 | 30.0 | False | None | None | False | None | False | 10938.6 | 0 | 3567343 | 129404 | None | code82 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Rmtr | 447.22 | 447.22 | 50.0 | False | None | None | False | None | False | 22361.0 | 0 | 3567344 | 129404 | None | code83 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Rmtr | 10.62 | 10.62 | 2000.0 | False | None | None | False | None | False | 21240.0 | 0 | 3567345 | 129404 | None | code84 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. 305.3.4 with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Cum | 123.9 | 123.9 | 225.0 | False | None | None | False | None | False | 27877.5 | 0 | 3567346 | 129404 | None | code85 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 160.48 | 160.48 | 3074.86 | False | None | None | False | None | False | 493453.5328 | 0 | 3567347 | 129404 | None | code86 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Curved Portion with all leads and lifts etc. complete as per specifications & as directed by Engineer-in-charge | Sqm | 5597.92 | 5597.92 | 36.0 | False | None | None | False | None | False | 201525.12 | 0 |
|