noticeInvitingTenderDTO
createdTs1721814719571
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd29275.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose07-08-2024 16:30:00
tenderQueryClose30-07-2024 17:00:00
technicalBidOpenNone
publishedDate24-07-2024 18:47:33
publishedByPostDMA_EE5_CC_MYS
publishedByUserKPE10951 - DEEPAK A E
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonvishwanath
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8660077550
tenderSupplierListNone
tenderSchedule
createdTs1721814719617
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/EL/WORK_INDENT22928
titleConversion of overhead aerial bunched cable to UG cable due to construction of new overhead water tank work in ward no 37 and shifting of transformer azeez sait nagar at zone-5 limits.
descriptionConversion of overhead aerial bunched cable to UG cable due to construction of new overhead water tank work in ward no 37 and shifting of transformer azeez sait nagar at zone-5 limits.
categoryWORKS
categoryTextWorks
ecv1165039.01
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2163
locationNameDMA City Corporation Mysuru
provisionalAmount1171000.0
groupOverheadTotalNone
fileNumberMCC/AEE-ELE/JE-5/64/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17218147200000NoneNoneElectricalConversion of overhead aerial bunched cable to UG cable due to construction of new overhead water tank work in ward no 37 and shifting of transformer azeez sait nagar at zone-5 limits.1165039.01
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3606700131085None001Pre-Stressed Tubular Spun Pole - 11 Mtr Long, 500 Kg WL No21932.7721932.772.0FalseNoneNoneFalseNoneFalse43865.540
3606701131085None002Labour charges for Erection of 11 Mtr long Concrete Spun Pole in a pit of 2.5 Mtr depth (Mechanised Labour)No3152.013152.012.0FalseNoneNoneFalseNoneFalse6304.020
3606702131085None003Labour charges for Digging of Pit 2.5 Mtr depth for erection of 11 Mtr long Tubular Spun Pole as per approved Drawing. - Ordinary Soil Per Pit2360.292360.292.0FalseNoneNoneFalseNoneFalse4720.580
3606703131085None00411 kV, Horizontal Cross Arm - Mild Steel (MS) No460.9460.95.0FalseNoneNoneFalseNoneFalse2304.50
3606704131085None00511 kV, 5 kN Composite/Polymeric Pin Insulator (24 mm dia FRP Rod) No253.99253.9915.0FalseNoneNoneFalseNoneFalse3809.850
3606705131085None00611 kV, 400 Amps Double Break GOS Set26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3606706131085None007H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - GI Set7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3606707131085None0098Labour charges for Fixing of GOS including wiring (11 kV Double Break 400 Amps) Set1504.151504.151.0FalseNoneNoneFalseNoneFalse1504.150
3606708131085None009Spiral Earth Electrode No296.12296.122.0FalseNoneNoneFalseNoneFalse592.240
3606709131085None010Labour charges for Providing Spiral Earth Electrode type earthing (without charcoal, salt etc.,) No115.23115.232.0FalseNoneNoneFalseNoneFalse230.460
3606710131085None011Rabbit ACSR(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM Km57283.9357283.930.15FalseNoneNoneFalseNoneFalse8592.58950
3606711131085None012Stringing of Rabbit ACSR conductor, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps. Per Km5403.285403.280.15FalseNoneNoneFalseNoneFalse810.4920
3606712131085None013Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr Coil640.57640.571.0FalseNoneNoneFalseNoneFalse640.570
3606713131085None01411 kV, 3 Core, XPLE HT UG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 - 95 Sqmm, (54 GI Wires - 2.5 mm Dia) Km1102296.181102296.180.34FalseNoneNoneFalseNoneFalse374780.70120
3606714131085None015Laying of HT UG cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff - 3x95 to 150 Sqmm Km75977.9675977.960.34FalseNoneNoneFalseNoneFalse25832.50640
3606715131085None016Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable - 3x95 Sqmm Per Kit5039.015039.016.0FalseNoneNoneFalseNoneFalse30234.060
3606716131085None017Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable - 3x95 Sqmm Per Kit4638.824638.822.0FalseNoneNoneFalseNoneFalse9277.640
3606717131085None018Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable - 3x240 Sqmm Per Kit5812.155812.154.0FalseNoneNoneFalseNoneFalse23248.60
3606718131085None019Labour charges for Heat shrinkable Type Terminations - 3x95 to 3x150 Sqmm Set3293.263293.268.0FalseNoneNoneFalseNoneFalse26346.080
3606719131085None020Cable Covering Tile 125x250x40 mm No12.712.7460.0FalseNoneNoneFalseNoneFalse5842.00
3606720131085None021Labour charges for Covering cable with Tiles Km5410.715410.710.2FalseNoneNoneFalseNoneFalse1082.1420
3606721131085None022Providing M-Sand : Supplying and filling in plinth, foundations / UG cable work with approved M-sand including watering, ramming, consolidating and dressing. The rate includes the cost of material, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer- in-charge of works as per the standard procedure. Cum2434.642434.645.0FalseNoneNoneFalseNoneFalse12173.20
3606722131085None023Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.-In all kinds of soils Depth upto 1.5 m Cum299.84299.84200.0FalseNoneNoneFalseNoneFalse59968.00
3606723131085None024Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete.- Light Duty GI pipe of 100mm Dia Mtr1312.11312.136.0FalseNoneNoneFalseNoneFalse47235.60
3606724131085None025Route & Joint indicating slab with MS Anchor rodNo164.79164.798.0FalseNoneNoneFalseNoneFalse1318.320
3606725131085None026Labour charges for Fixing of Route & Joint Indicating SlabNo143.72143.728.0FalseNoneNoneFalseNoneFalse1149.760
3606726131085None027Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit. The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaNo4348.94348.96.0FalseNoneNoneFalseNoneFalse26093.40
3606727131085None028LT 4 Pin Cross Arm - GI No469.59469.594.0FalseNoneNoneFalseNoneFalse1878.360
3606728131085None029Labour charges for Fixing of 4 Pin cross arm with Insulator and Braces fixing No198.24198.244.0FalseNoneNoneFalseNoneFalse792.960
3606729131085None0301.1 kV Polymeric Pin Insulator No107.8107.82.0FalseNoneNoneFalseNoneFalse215.60
3606730131085None031LT 2 Pin Cross Arms - GI No214.35214.352.0FalseNoneNoneFalseNoneFalse428.70
3606731131085None032Labour charges for Fixing of 4 Pin cross arm with Insulator and Braces fixing No198.24198.242.0FalseNoneNoneFalseNoneFalse396.480
3606732131085None033No. 8 Strain Insulator No33.4533.455.0FalseNoneNoneFalseNoneFalse167.250
3606733131085None0341.1 kV Ceramic Pin Insulator (Shell only) No38.4138.415.0FalseNoneNoneFalseNoneFalse192.050
3606734131085None0351.1 kV GI Pin for 1.1 kV Ceramic Shell Insulator No43.3743.375.0FalseNoneNoneFalseNoneFalse216.850
3606735131085None03610 kV, 5 kA Lightning Arrester Polymeric type with GROUND DISCONNECTOR Set of 3 Nos1962.581962.581.0FalseNoneNoneFalseNoneFalse1962.580
3606736131085None037Fixing of 3 Nos Lightning Arrestor including wiring Set of 3 Nos147.44147.441.0FalseNoneNoneFalseNoneFalse147.440
3606737131085None03811 kV, HG Fuse Unit with Solid Core Insulator Set of 3 Nos1324.51324.51.0FalseNoneNoneFalseNoneFalse1324.50
3606738131085None039Labour charges for Fixing HG Fuse unit including fixing of cross arm and wiring Set of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3606739131085None040LT Distribution Box for 100/250 kVA DTC with MCCB's (SMC) No30266.330266.31.0FalseNoneNoneFalseNoneFalse30266.30
3606740131085None041Fixing LT Distribution box for 100/250/500 kVA DTC (Excluding wiring) Per Box477.02477.021.0FalseNoneNoneFalseNoneFalse477.020
3606741131085None0421.1 KV Class HR (Heat Resistant) PVC Insulated & UnSheathed Aluminium Wires Multistrand Single Core Lead wires as per IS-694: 2010 - PVC Wire - 120 Sq.mm Al Wt: 32 Kg, Total Wt: 45.5Kg/100 Mtr Coil Coil17741.2417741.241.0FalseNoneNoneFalseNoneFalse17741.240
3606742131085None043Heavy Duty Copper Terminal Long Barrel - 120 Sqmm Copper Terminal, Apprx Wt: 64 Gm No173.46173.4624.0FalseNoneNoneFalseNoneFalse4163.040
3606743131085None044PG Clamp Rabbit to Insulated Wire - 120 Sqmm No338.25338.2512.0FalseNoneNoneFalseNoneFalse4059.00
3606744131085None045LT Line Spacer - For 4 Wire No87.9287.9216.0FalseNoneNoneFalseNoneFalse1406.720
3606745131085None046GI Fish Plate No110.28110.284.0FalseNoneNoneFalseNoneFalse441.120
3606746131085None0471.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm) Km1068843.171068843.170.14FalseNoneNoneFalseNoneFalse149638.04380
3606747131085None048Laying of LT UG cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff - 120 to 240 Sqmm Km39992.4439992.440.14FalseNoneNoneFalseNoneFalse5598.94160
3606748131085None049Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LT UG Cable - 3.5 x 225/240/300 Sqmm Set728.53728.534.0FalseNoneNoneFalseNoneFalse2914.120
3606749131085None050Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerin-charge. (Made of G.I. wire of dia 4 mm)(Item no 11.58)[PWD SR 2023-24 Buildings Vol-II] Sqm994.92994.9215.0FalseNoneNoneFalseNoneFalse14923.80
3606750131085None051Releasing & re-erection of 100 kVA Transformer Each3743.023743.021.0FalseNoneNoneFalseNoneFalse3743.020
3606751131085None052Releasing & re-Fixing of GOS including wiring (11 kV Single Break 200 Amps) Set2598.932598.931.0FalseNoneNoneFalseNoneFalse2598.930
3606752131085None053Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cum7789.67789.62.0FalseNoneNoneFalseNoneFalse15579.20
3606753131085None054Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete etc. complete. NOTE: Upto 110mm dia Coil shall be used. - HDPE Grade PE80 PN 3.0, 110mm dia Mtr379.13379.13400.0FalseNoneNoneFalseNoneFalse151652.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17218147200000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17218147200000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17218147200000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17218147200000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17218147200000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17218147200000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17218147200000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17218147200000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17218147200000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17218147200000NoneNoneELIGIBILITYBanker DetailsNone
17218147660000NoneNoneELIGIBILITYALL AS PER BID DOCUMENT CONDITIONSNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Bidder should have valid Class-3 and above Registered Electrical Contractor License issued from Public Work Department or Inspectorate of ElectricityTrueTechnical Bid
The bidder should submit the GST/PAN Registration Certificate.TrueTechnical Bid
Tenderer in their name should submit annual turnover certificate any two years from last five years i.e., 2019-20 to 2023-24 of Rs.11.71Lakhs in each year.The turn over certificate should be mandatorily certified from charted accountant and mention UDIN number is compulsory, otherwise it will be subjected to rejectionTrueTechnical Bid
The Tenderer should have at least executed and satisfactorily completed as prime contractor, at least one Similar Electrical work in any Govt. Agency/ULBs/PSU for amount not less than Rs.5.85 Lakhs in Last Five Years i.e., 2019-20, 2020-21, 2021-22& 2022-23,2023-24. NOTE The work done certificate submitted should be signed not less than the rank of Executive Engineer/Equivalent grade officer and also mention the E-procurement indent numberTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone