tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1721025031000 | 0 | None | None | Buildings | Construction of Sump and Providing water supply connection from sump to Prison building at Nanjanagudu Sub Prison, Nanjanagudu, Mysore. | 1281893.64 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3524135 | 126637 | None | 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m | Cum | 123.97 | 123.97 | 128.78 | False | None | None | False | None | False | 15964.8566 | 0 | 3524136 | 126637 | None | 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Cum | 143.42 | 143.42 | 51.51 | False | None | None | False | None | False | 7387.5642 | 0 | 3524137 | 126637 | None | 2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7279.03 | 7279.03 | 11.35 | False | None | None | False | None | False | 82616.9905 | 0 | 3524138 | 126637 | None | 2.4.4 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications., 2.4.4 M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Raft | Cum | 8849.77 | 8849.77 | 16.46 | False | None | None | False | None | False | 145667.2142 | 0 | 3524139 | 126637 | None | 2.4.4 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications., 2.4.4 M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - RCC Walls | Cum | 11062.2 | 11062.2 | 12.33 | False | None | None | False | None | False | 136396.926 | 0 | 3524140 | 126637 | None | 2.4.4 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications., 2.4.4 M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For base and Edges | Cum | 8849.76 | 8849.76 | 1.75 | False | None | None | False | None | False | 15487.08 | 0 | 3524141 | 126637 | None | 2.4.4 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications., 2.4.4 M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Roof Slab | Cum | 12291.34 | 12291.34 | 4.53 | False | None | None | False | None | False | 55679.7702 | 0 | 3524142 | 126637 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 323.3 | 323.3 | 39.04 | False | None | None | False | None | False | 12621.632 | 0 | 3524143 | 126637 | None | 2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification, a. Buildings | Tonne | 108726.04 | 108726.04 | 3.569 | False | None | None | False | None | False | 388043.23676 | 0 | 3524144 | 126637 | None | 8.3.2 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 404.73 | 404.73 | 232.3 | False | None | None | False | None | False | 94018.779 | 0 | 3524145 | 126637 | None | 8.12 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin- Charge. | Kg | 77.79 | 77.79 | 69.69 | False | None | None | False | None | False | 5421.1851 | 0 | 3524146 | 126637 | None | 7.3 | Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc | Each | 2600.96 | 2600.96 | 2.0 | False | None | None | False | None | False | 5201.92 | 0 | 3524147 | 126637 | None | 7.12.1 | Ladder inside the container: Providing anodized aluminium ladder using 65mm x 32mm x 3.0mm ‘C’ section for ladder side channel x 25mm dia., flutal pipe for Rungs at 250mm c/c ladder fixed at an angle of 70 degrees to horizontal including necessary 25mm dia., G.I. shutters with necessary G.I. fasteners for bracing the ladders to the Tank walls to prevent buckling of the ladder with necessary (M15) bed for embedding the ladder bottom complet | m | 6198.54 | 6198.54 | 4.6 | False | None | None | False | None | False | 28513.284 | 0 | 3524148 | 126637 | None | 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet & over flow pipes. but without fittings and the base support tank | l | 10.94 | 10.94 | 6000.0 | False | None | None | False | None | False | 65640.0 | 0 | 3524149 | 126637 | None | 13.32.3 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. as per direction of Engineer incharge. Conceled work including cutting chasses and making good the wall etc.,. 25mm nominal OD Pipes | m | 386.5 | 386.5 | 250.0 | False | None | None | False | None | False | 96625.0 | 0 | 3524150 | 126637 | None | 13.31.4 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. as per direction of Engineer incharge. Conceled work including cutting chasses and making good the wall etc., 32mm nominal OD Pipes | m | 486.16 | 486.16 | 200.0 | False | None | None | False | None | False | 97232.0 | 0 | 3524151 | 126637 | None | 13.4.1 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore | Nos | 667.25 | 667.25 | 10.0 | False | None | None | False | None | False | 6672.5 | 0 | 3524152 | 126637 | None | 13.4.2 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore | Nos | 726.81 | 726.81 | 10.0 | False | None | None | False | None | False | 7268.1 | 0 | 3524153 | 126637 | None | 13.12 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 | Nos | 771.78 | 771.78 | 20.0 | False | None | None | False | None | False | 15435.6 | 0 |
| 1721025031000 | 0 | None | None | Buildings | Electrification for the Construction of Sump and Providing water supply connection from sump to Prison building at Nanjanagudu Sub Prison, Nanjanagudu, Mysore. | 61711.34 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3524154 | 126638 | None | Civil SR 18-19 | Supplying , fixing & wiring of Open well Mono Sub pump set 3 HP suitable for operation on 440 volts 2800 RPM Three phase AC supply after aligning, leveling & assembling etc, inclusive of transportation charges to work spot, as per the directions of engineer incharge of the work. | Set | 19824.0 | 19824.0 | 1.0 | False | None | None | False | None | False | 19824.0 | 0 | 3524155 | 126638 | None | NSR | Fixing charges of pumpset after aligning, leveling & assembling etc, inclusive of transportation charges to work spot. | Nos | 590.0 | 590.0 | 1.0 | False | None | None | False | None | False | 590.0 | 0 | 3524156 | 126638 | None | 5.1 | Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP. as per the directions of Engineer in charge of the work. | Each | 2273.86 | 2273.86 | 1.0 | False | None | None | False | None | False | 2273.86 | 0 | 3524157 | 126638 | None | 5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machineries like induction motor ,as per the directions of Engineer in charge of the work. | Kvar | 566.4 | 566.4 | 2.0 | False | None | None | False | None | False | 1132.8 | 0 | 3524158 | 126638 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C 50Hz 12/24v D.C. and as per the directions of Engineer in charge of the work. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3524159 | 126638 | None | 5.6.6 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. 20"X20"x2.5" ,as per the directions of Engineer in charge of the work. | Each | 384.84 | 384.84 | 1.0 | False | None | None | False | None | False | 384.84 | 0 | 3524160 | 126638 | None | 2.6.2 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper
with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed
suitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 4 mm2 | Mtr | 198.24 | 198.24 | 20.0 | False | None | None | False | None | False | 3964.8 | 0 | 3524161 | 126638 | None | 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Nos | 4141.8 | 4141.8 | 1.0 | False | None | None | False | None | False | 4141.8 | 0 | 3524162 | 126638 | None | 32.09 | Supplying of 1.1 kV, XLPE or Heat resistant PVC
insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 a) 35 Sqmm, 3.5 Core, (14 GI Strips - 4 x 0.8 mm) | Mtr | 166.47 | 166.47 | 80.0 | False | None | None | False | None | False | 13317.6 | 0 | 3524163 | 126638 | None | 21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable | Mtr | 24.64 | 24.64 | 80.0 | False | None | None | False | None | False | 1971.2 | 0 | 3524164 | 126638 | None | Ele SR 19-20 6.6.1 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) In soil (ordinary) | Mtr | 89.68 | 89.68 | 70.0 | False | None | None | False | None | False | 6277.6 | 0 | 3524165 | 126638 | None | Ele SR 19-20 6.9.1 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV. 40 mm | Mtr | 395.3 | 395.3 | 5.0 | False | None | None | False | None | False | 1976.5 | 0 | 3524166 | 126638 | None | 5.18.7 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 a) 6-32 A TPN | Each | 2026.06 | 2026.06 | 1.0 | False | None | None | False | None | False | 2026.06 | 0 | 3524167 | 126638 | None | 5.5.1 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved
colour. 32 A | Each | 2007.18 | 2007.18 | 1.0 | False | None | None | False | None | False | 2007.18 | 0 |
| 1721025031000 | 0 | None | None | Buildings | Construction of Toilets for staff at Nanjanagudu sub prison, Nanjanagudu, Mysore. | 675898.08 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3524168 | 126639 | None | 1.4.1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m | Cum | 294.13 | 294.13 | 12.9 | False | None | None | False | None | False | 3794.277 | 0 | 3524169 | 126639 | None | 2.1.4 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7556.14 | 7556.14 | 5.28 | False | None | None | False | None | False | 39896.4192 | 0 | 3524170 | 126639 | None | 5.4 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 7765.19 | 7765.19 | 13.61 | False | None | None | False | None | False | 105684.2359 | 0 | 3524171 | 126639 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited. | Cum | 323.3 | 323.3 | 9.03 | False | None | None | False | None | False | 2919.399 | 0 | 3524172 | 126639 | None | 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications., M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Plinth Beam | Cum | 11551.16 | 11551.16 | 1.35 | False | None | None | False | None | False | 15594.066 | 0 | 3524173 | 126639 | None | 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications., M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Lintel | Cum | 12321.24 | 12321.24 | 0.13 | False | None | None | False | None | False | 1601.7612 | 0 | 3524174 | 126639 | None | 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications., M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Roof Slab | Cum | 11551.16 | 11551.16 | 3.67 | False | None | None | False | None | False | 42392.7572 | 0 | 3524175 | 126639 | None | 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1592.17 | 1592.17 | 51.42 | False | None | None | False | None | False | 81869.3814 | 0 | 3524176 | 126639 | None | 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1341.8 | 1341.8 | 10.29 | False | None | None | False | None | False | 13807.122 | 0 | 3524177 | 126639 | None | 2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification, a. Buildings | Tonne | 108726.04 | 108726.04 | 0.56 | False | None | None | False | None | False | 60886.5824 | 0 | 3524178 | 126639 | None | 12.85 | Providing fixing of louvered ventilator made out of multi chambered UPVC Matching to RAL 9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the ventilator frame. The frame having overall size of 39mm X 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm X 1000mm.The cost is inclusive of all fixtures and separate charges for minor TP's shall not be made | Sqm | 6950.87 | 6950.87 | 1.44 | False | None | None | False | None | False | 10009.2528 | 0 | 3524179 | 126639 | None | 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | m | 386.5 | 386.5 | 23.4 | False | None | None | False | None | False | 9044.1 | 0 | 3524180 | 126639 | None | 12.55.2 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.-do- with one side prelam | Sqm | 2479.4 | 2479.4 | 6.93 | False | None | None | False | None | False | 17182.242 | 0 | 3524181 | 126639 | None | 9.9 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment
etc., complete. | Sqm | 1307.77 | 1307.77 | 16.74 | False | None | None | False | None | False | 21892.0698 | 0 | 3524182 | 126639 | None | 9.38 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1691.84 | 1691.84 | 16.92 | False | None | None | False | None | False | 28625.9328 | 0 | 3524183 | 126639 | None | 8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Inside) | Sqm | 309.93 | 309.93 | 69.69 | False | None | None | False | None | False | 21599.0217 | 0 | 3524184 | 126639 | None | 8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 339.1 | 339.1 | 16.92 | False | None | None | False | None | False | 5737.572 | 0 | 3524185 | 126639 | None | 8.3.2 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 404.73 | 404.73 | 82.36 | False | None | None | False | None | False | 33333.5628 | 0 | 3524186 | 126639 | None | 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
charge. | Sqm | 121.54 | 121.54 | 69.69 | False | None | None | False | None | False | 8470.1226 | 0 | 3524187 | 126639 | None | 8.55.2 | Applying priming coat with primer of approved brand and manufacturer, having low VOC ( Volatile Organic Compound) content with water thinnable cement primer on wall surface having VOC content less than 50 grams / litre as per specifications and as and as per directions of Engineer-in-charge. | Sqm | 64.42 | 64.42 | 69.69 | False | None | None | False | None | False | 4489.4298 | 0 | 3524188 | 126639 | None | 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. for internal walls | Sqm | 154.36 | 154.36 | 69.69 | False | None | None | False | None | False | 10757.3484 | 0 | 3524189 | 126639 | None | 8.31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.- External walls | Sqm | 216.34 | 216.34 | 82.36 | False | None | None | False | None | False | 17817.7624 | 0 | 3524190 | 126639 | None | 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 204.19 | 204.19 | 30.24 | False | None | None | False | None | False | 6174.7056 | 0 | 3524191 | 126639 | None | 1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. 1.6.1 In all kinds of soils. Depth upto 1.50m. | Cum | 588.25 | 588.25 | 18.0 | False | None | None | False | None | False | 10588.5 | 0 | 3524192 | 126639 | None | 14.2.2 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked black solid plastic seat and lid. | Each | 5876.46 | 5876.46 | 2.0 | False | None | None | False | None | False | 11752.92 | 0 | 3524193 | 126639 | None | 14.5.1 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever
required : 14.5.1 Single half stall urinal with 5 litre P.V.C. automatic flushing cistern | Each | 10503.49 | 10503.49 | 1.0 | False | None | None | False | None | False | 10503.49 | 0 | 3524194 | 126639 | None | 14.16A | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. | Each | 330.59 | 330.59 | 2.0 | False | None | None | False | None | False | 661.18 | 0 | 3524195 | 126639 | None | 14.7.3 | White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps | Each | 3483.34 | 3483.34 | 2.0 | False | None | None | False | None | False | 6966.68 | 0 | 3524196 | 126639 | None | 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Each | 1482.79 | 1482.79 | 2.0 | False | None | None | False | None | False | 2965.58 | 0 | 3524197 | 126639 | None | 14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 602.84 | 602.84 | 4.0 | False | None | None | False | None | False | 2411.36 | 0 | 3524198 | 126639 | None | 13.22.1.1 | Providing and fixing PTMT grating of approved quality and colour Circular type 100 mm nominal dia | Nos | 49.83 | 49.83 | 4.0 | False | None | None | False | None | False | 199.32 | 0 | 3524199 | 126639 | None | 13.59 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete | Nos | 267.39 | 267.39 | 4.0 | False | None | None | False | None | False | 1069.56 | 0 | 3524200 | 126639 | None | 13.12 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 | Nos | 771.78 | 771.78 | 4.0 | False | None | None | False | None | False | 3087.12 | 0 | 3524201 | 126639 | None | 13.15 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. | Nos | 881.17 | 881.17 | 4.0 | False | None | None | False | None | False | 3524.68 | 0 | 3524202 | 126639 | None | 13.32.2 | Providing and fixing chorinated poly vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (external) & (Concealed work including cutting chasses & good the wall Etc)-20mm dia | m | 460.64 | 460.64 | 20.0 | False | None | None | False | None | False | 9212.8 | 0 | 3524203 | 126639 | None | 13.32.3 | Providing and fixing chorinated poly vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (external) & (Concealed work including cutting chasses & good the wall Etc)-25mm dia | m | 579.75 | 579.75 | 20.0 | False | None | None | False | None | False | 11595.0 | 0 | 3524204 | 126639 | None | 10.1.5 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 10.1.5 PVC pipes 75mm dia., 6 kg/sqcm & class 3 - 75mm dia | m | 267.39 | 267.39 | 20.0 | False | None | None | False | None | False | 5347.8 | 0 | 3524205 | 126639 | None | 10.1.7 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 10.1.5 PVC pipes 110mm dia., 6 kg/sqcm & class 3 - 110mm dia | m | 499.53 | 499.53 | 35.0 | False | None | None | False | None | False | 17483.55 | 0 | 3524206 | 126639 | None | 16.1 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover 450x450mm and 450mm depth | Each | 5148.43 | 5148.43 | 2.0 | False | None | None | False | None | False | 10296.86 | 0 | 3524207 | 126639 | None | 16.23.1 | Supplying and fixing SFRC frame and cover confirming to IS 12912(Part 1-1988 & IS 12592 Part II-1991) with latest ammendment including cutting slabs to the required size for opening and fixing the cover in CC 1:2:4 and CM 1:3 plastering 20mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. Complete - Medium duty | Set | 2326.28 | 2326.28 | 2.0 | False | None | None | False | None | False | 4652.56 | 0 |
| 1721025031000 | 0 | None | None | Buildings | Electrification for the Construction of Toilets for staff at Nanjanagudu sub prison, Nanjanagudu, Mysore. | 43720.2 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3524208 | 126640 | None | 1.2.1 | Electrical - Concealed Conduit System Supplying heavy gauge PVC conduit pipe …19/20…mm dia .2..mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary,as per the directions of Engineer in charge of the work. 1) 19/20mm dia 2mm thick | Mtr | 77.88 | 77.88 | 25.0 | False | None | None | False | None | False | 1947.0 | 0 | 3524209 | 126640 | None | 1.3.1 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive
paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and
run with 18 SWG GI fish wire run throughout the conduit wherever necessary. | Mtr | 80.24 | 80.24 | 20.0 | False | None | None | False | None | False | 1604.8 | 0 | 3524210 | 126640 | None | 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting
in Brick/Stone/C.C wall ,as per the directions of Engineer in charge of the work. i) 1-3Way | Each | 162.84 | 162.84 | 2.0 | False | None | None | False | None | False | 325.68 | 0 | 3524211 | 126640 | None | 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,as per the directions of Engineer in charge of the work. iii) 8Way | Each | 259.6 | 259.6 | 2.0 | False | None | None | False | None | False | 519.2 | 0 | 3524212 | 126640 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box ,as per the directions of Engineer in charge of the work. i)1 to 3 Module | Each | 161.66 | 161.66 | 2.0 | False | None | None | False | None | False | 323.32 | 0 | 3524213 | 126640 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. and as per the directions of Engineer in charge of the work. iv) 8 Module | Each | 276.12 | 276.12 | 2.0 | False | None | None | False | None | False | 552.24 | 0 | 3524214 | 126640 | None | 2.2.1 | Point wiring using copper wire with out switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSH multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. as per the directions of Engineer in charge of the work. 1) Short point upto 3Mtr. from tapping point to out let via switch. | Point | 317.42 | 317.42 | 6.0 | False | None | None | False | None | False | 1904.52 | 0 | 3524215 | 126640 | None | 2.2.3 | Point wiring using copper wire with out switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSH multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. as per the directions of Engineer in charge of the work. c) Long point above 6Mtr. Upto 10Mtr. from tapping point to out let via switch. | Point | 654.9 | 654.9 | 8.0 | False | None | None | False | None | False | 5239.2 | 0 | 3524216 | 126640 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLSH PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments ,as per the directions of Engineer in charge of the work. 1) 1.5 Sqmm | Mtr | 30.68 | 30.68 | 25.0 | False | None | None | False | None | False | 767.0 | 0 | 3524217 | 126640 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLSH PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments ,as per the directions of Engineer in charge of the work. 2) 2.5 Sqmm | Mtr | 49.56 | 49.56 | 40.0 | False | None | None | False | None | False | 1982.4 | 0 | 3524218 | 126640 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. i) 6 Amps one way switch | Each | 120.36 | 120.36 | 15.0 | False | None | None | False | None | False | 1805.4 | 0 | 3524219 | 126640 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. ii) 6 Amps 3 way socket | Each | 201.78 | 201.78 | 2.0 | False | None | None | False | None | False | 403.56 | 0 | 3524220 | 126640 | None | 3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. 32Amps DP switch | Each | 384.68 | 384.68 | 2.0 | False | None | None | False | None | False | 769.36 | 0 | 3524221 | 126640 | None | 11.3.2 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70percentage lumen maintenance with CRI greater than 80. Power Input: 220-240V at 50/60Hz & Power factor less than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect
working under standard electrical condition.
LED light fitting 1 x 4' - 20/22 W | Nos | 814.2 | 814.2 | 2.0 | False | None | None | False | None | False | 1628.4 | 0 | 3524222 | 126640 | None | 13.7.1 | Fixing all types and all capacities of LED light fittings indoor on the wall / ceiling /
rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks , holder with adopter and clamps.. a) On wall/ceiling/Rafter/Girders ,as per the directions of Engineer in charge of the work. | No | 143.96 | 143.96 | 2.0 | False | None | None | False | None | False | 287.92 | 0 | 3524223 | 126640 | None | 11.11.4 | Supplying & fixing of retrofit type - LED bulb 9 W withOPAL acrylic diffuser comprising of LED source with CCT 6500degree K, CRI greater than 70 Percentage. efficacy less than 80 lumen per W, life less than 25000
burning hours and Compliance to IS 10322/IEC 60598, LM 79& LM 80. The LED are driven by HF electronic driver integratedin the system, with PF greater than 0.95, power loss should less than 5percent of lamp
Wage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS
Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect
working under standard electrical condition. 9W | No | 181.72 | 181.72 | 4.0 | False | None | None | False | None | False | 726.88 | 0 | 3524224 | 126640 | None | 6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. and as per the directions of Engineer in charge of the work. | Each | 1760.56 | 1760.56 | 2.0 | False | None | None | False | None | False | 3521.12 | 0 | 3524225 | 126640 | None | 13.14 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 2.0 | False | None | None | False | None | False | 1161.12 | 0 | 3524226 | 126640 | None | SR 14-15 4.3.1 | Supplying and fixing cast Aluminium round or oblong type bulk head fitting with GI wire guard, glass cover with 60/100 watts 230V GLS lamp as required( 20 /4.3) | Each | 881.46 | 881.46 | 2.0 | False | None | None | False | None | False | 1762.92 | 0 | 3524227 | 126640 | None | Bescom SR 23.24 32.05 | Supplying of 1.1 kV, XLPE or Heat resistant PVC
insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 a) 4 core 16 sqmm | Mtr | 167.37 | 167.37 | 50.0 | False | None | None | False | None | False | 8368.5 | 0 | 3524228 | 126640 | None | Bescom SR 23.24 21.05 | Labour charges for Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff a) 25 sqmm to 75 sqmm | Mtr | 24.64 | 24.64 | 50.0 | False | None | None | False | None | False | 1232.0 | 0 | 3524229 | 126640 | None | Ele SR 2019-20 6.9.1 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class. and as per the directions of Engineer in charge of the work. 1) 40 mm | Mtr | 395.3 | 395.3 | 5.0 | False | None | None | False | None | False | 1976.5 | 0 | 3524230 | 126640 | None | 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP and as per the directions of Engineer in charge of the work. | Each | 489.7 | 489.7 | 2.0 | False | None | None | False | None | False | 979.4 | 0 | 3524231 | 126640 | None | 5.18.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 2) 6-32Amps DP and as per the directions of Engineer in charge of the work. | Each | 872.02 | 872.02 | 2.0 | False | None | None | False | None | False | 1744.04 | 0 | 3524232 | 126640 | None | 5.19.8 | Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. Double Door 8 Way SP &N and as per the directions of Engineer in charge of the work | Each | 2187.72 | 2187.72 | 1.0 | False | None | None | False | None | False | 2187.72 | 0 |
| 1721025031000 | 0 | None | None | Buildings | Construction of Security Cabin infront of gate at Central Prison, Mysuru. | 148784.01 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3524233 | 126641 | None | 1.4.1 | Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges andsuch simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Common SR 2023-24 Vol-1 P.No 8 Item No 1.14.1 (In All kinds of soils Depath upto 1.5m). | Cum | 299.84 | 299.84 | 2.38 | False | None | None | False | None | False | 713.6192 | 0 | 3524234 | 126641 | None | 2.1.4 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates Common SR 2023-24 Vol-1 P.No.15, It.No 2.1.4, | Cum | 7702.86 | 7702.86 | 0.29 | False | None | None | False | None | False | 2233.8294 | 0 | 3524235 | 126641 | None | 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Common SR 2023-24 Vol-2 P.No.9, It.No 5.4, | Cum | 7915.97 | 7915.97 | 1.46 | False | None | None | False | None | False | 11557.3162 | 0 | 3524236 | 126641 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Common SR 2023-24 Vol-1 P.No.17 .No.2.5.1 | Cum | 8214.57 | 8214.57 | 0.38 | False | None | None | False | None | False | 3121.5366 | 0 | 3524237 | 126641 | None | 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Common SR Vol-2 P.No. 17 Item No 6.32, | Sqm | 1623.09 | 1623.09 | 3.75 | False | None | None | False | None | False | 6086.5875 | 0 | 3524238 | 126641 | None | 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) tobrick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.CSR Vol-2 P.No. 41 I.No. 8.3.1 | Sqm | 438.61 | 438.61 | 7.5 | False | None | None | False | None | False | 3289.575 | 0 | 3524239 | 126641 | None | 7.67.2 | Providing,fabricating and fixing Profiled Poly Urethane insulated Roof(PUF Sheet) having modular density 40kg/m2 and size 1.06m width and 7.60m length sheets roof having external sheet of 0.5mm steel, bottom sheet of 0.40mm steel with powder coated finish. The precoated sheet shall be of minimum 240MPa steel conforming to IS 14246 : 1995 and shal have zinc coating with minimum 120gsm as per IS 277:1992,.The roofing system shall have suitable water proof over lapping arrangments and GRIHA ceritifed.The fasting shall be of self tapping screws of required length with PVC head along with washer pre-painted aluminium cap unit with build in seal arrangments. The entire roof shall be firmly fastened to the existng frame including all lead and lifts, loading & unloading ,usage charges of machinery and equipments, transportation charges,labour charges and all other incidental charges etc.,complete as per standard technical detailed specifications and as directed by the Engineer in charge of the work. 50mm thickness Common SR 2023-24 Vol-2 P.No. 38 I.No. 7.67.2 | Sqm | 3215.21 | 3215.21 | 6.75 | False | None | None | False | None | False | 21702.6675 | 0 | 3524240 | 126641 | None | 8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after
thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Common SR 2023-24 Vol-2 P.No. 45 I.No.8.25 | Sqm | 169.74 | 169.74 | 7.5 | False | None | None | False | None | False | 1273.05 | 0 | 3524241 | 126641 | None | 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye River Pink or equivalent. . Common SR 2023-24 Vol-2 P.No. 63 I.No. 9.24 | Sqm | 3533.63 | 3533.63 | 4.85 | False | None | None | False | None | False | 17138.1055 | 0 | 3524242 | 126641 | None | 11.37.2 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. Common SR 2023-24 Vol-2 P.No. 88 I.No. 11.37.2 | Sqm | 1450.87 | 1450.87 | 4.77 | False | None | None | False | None | False | 6920.6499 | 0 | 3524243 | 126641 | None | 11.35.1.1 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to
IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. | Kgs | 560.03 | 560.03 | 14.3 | False | None | None | False | None | False | 8008.429 | 0 | 3524244 | 126641 | None | 11.11.1 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard
rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete
block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) including cost of materials, labour, usage
charges of machinery complete as per specifications and as per directions
of the Engineer-in-Charge. Common SR 2023-24 Vol-2 P.No. 77 I.No. 11.11.1 | Kg | 183.37 | 183.37 | 1.58 | False | None | None | False | None | False | 289.7246 | 0 | 3524245 | 126641 | None | 11.2 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel
primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Common SR 2023-24 Vol-2 P.No. 75 I.No. 11.2 | Kgs | 140.01 | 140.01 | 450.0 | False | None | None | False | None | False | 63004.5 | 0 | 3524246 | 126641 | None | 8.33.3 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Common SR 2023-24 Vol-2 P.No. 47 I.No. 8.33.3 | Sqm | 172.22 | 172.22 | 20.0 | False | None | None | False | None | False | 3444.4 | 0 |
| 1721025031000 | 0 | None | None | Buildings | Electrification for the Construction of Security Cabin infront of gate at Central Prison, Mysuru. | 13958.22 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3524247 | 126642 | None | 1.2.1 | Electrical - Concealed Conduit System Supplying heavy gauge PVC conduit pipe …19/20…mm dia .2..mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary,as per the directions of Engineer in charge of the work. 1) 19/20mm dia 2mm thick | Mtr | 77.88 | 77.88 | 10.0 | False | None | None | False | None | False | 778.8 | 0 | 3524248 | 126642 | None | 1.3.1 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive
paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and
run with 18 SWG GI fish wire run throughout the conduit wherever necessary. | Mtr | 80.24 | 80.24 | 5.0 | False | None | None | False | None | False | 401.2 | 0 | 3524249 | 126642 | None | 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting
in Brick/Stone/C.C wall ,as per the directions of Engineer in charge of the work. i) 1-3Way | Each | 162.84 | 162.84 | 1.0 | False | None | None | False | None | False | 162.84 | 0 | 3524250 | 126642 | None | 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,as per the directions of Engineer in charge of the work. iii) 8Way | Each | 307.98 | 307.98 | 1.0 | False | None | None | False | None | False | 307.98 | 0 | 3524251 | 126642 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box ,as per the directions of Engineer in charge of the work. i)1 to 3 Module | Each | 161.66 | 161.66 | 1.0 | False | None | None | False | None | False | 161.66 | 0 | 3524252 | 126642 | None | 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. and as per the directions of Engineer in charge of the work. iv) 8 Module | Each | 335.12 | 335.12 | 1.0 | False | None | None | False | None | False | 335.12 | 0 | 3524253 | 126642 | None | 2.2.1 | Point wiring using copper wire with out switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSH multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. as per the directions of Engineer in charge of the work. 1) Short point upto 3Mtr. from tapping point to out let via switch. | Point | 317.42 | 317.42 | 2.0 | False | None | None | False | None | False | 634.84 | 0 | 3524254 | 126642 | None | 2.2.3 | Point wiring using copper wire with out switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSH multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. as per the directions of Engineer in charge of the work. c) Long point above 6Mtr. Upto 10Mtr. from tapping point to out let via switch. | Point | 654.9 | 654.9 | 4.0 | False | None | None | False | None | False | 2619.6 | 0 | 3524255 | 126642 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLSH PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments ,as per the directions of Engineer in charge of the work. 1) 1.5 Sqmm | Mtr | 30.68 | 30.68 | 15.0 | False | None | None | False | None | False | 460.2 | 0 | 3524256 | 126642 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLSH PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments ,as per the directions of Engineer in charge of the work. 2) 2.5 Sqmm | Mtr | 49.56 | 49.56 | 20.0 | False | None | None | False | None | False | 991.2 | 0 | 3524257 | 126642 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. i) 6 Amps one way switch | Each | 120.36 | 120.36 | 8.0 | False | None | None | False | None | False | 962.88 | 0 | 3524258 | 126642 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. ii) 6 Amps 3 way socket | Each | 191.16 | 191.16 | 1.0 | False | None | None | False | None | False | 191.16 | 0 | 3524259 | 126642 | None | 11.3.2 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70Percent lumen maintenance with CRI greater than 80. Power Input: 220-240V at 50/60Hz & Power factor Greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect
working under standard electrical condition.
LED light fitting 1 x 4' - 20/22 W | Nos | 814.2 | 814.2 | 1.0 | False | None | None | False | None | False | 814.2 | 0 | 3524260 | 126642 | None | 13.7.1 | Fixing all types and all capacities of LED light fittings indoor on the wall / ceiling /
rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks , holder with adopter and clamps.. a) On wall/ceiling/Rafter/Girders ,as per the directions of Engineer in charge of the work. | No | 143.96 | 143.96 | 1.0 | False | None | None | False | None | False | 143.96 | 0 | 3524261 | 126642 | None | 11.11.4 | Supplying & fixing of retrofit type - LED bulb 9 W withOPAL acrylic diffuser comprising of LED source with CCT 6500degree K, CRI greater than 70percent. efficacy greater than 80 lumen per W, life greater than 25000
burning hours and Compliance to IS 10322/IEC 60598, LM 79& LM 80. The LED are driven by HF electronic driver integratedin the system, with PF greater than 0.95, power loss should less than 5% of lamp
Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS
Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect
working under standard electrical condition. 9W | No | 181.72 | 181.72 | 2.0 | False | None | None | False | None | False | 363.44 | 0 | 3524262 | 126642 | None | 6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. and as per the directions of Engineer in charge of the work. | Each | 1760.56 | 1760.56 | 1.0 | False | None | None | False | None | False | 1760.56 | 0 | 3524263 | 126642 | None | 13.14 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 1.0 | False | None | None | False | None | False | 580.56 | 0 | 3524264 | 126642 | None | 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP and as per the directions of Engineer in charge of the work. | Each | 489.7 | 489.7 | 1.0 | False | None | None | False | None | False | 489.7 | 0 | 3524265 | 126642 | None | 5.19.6 | Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. Double Door 4 Way SP &N and as per the directions of Engineer in charge of the work | Each | 1798.32 | 1798.32 | 1.0 | False | None | None | False | None | False | 1798.32 | 0 |
|
|
---|