tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1721736462000 | 1 | None | None | Buildings | Ground Floor Construction of Seven Class rooms to Jai Hind No-1 Government Higher Primary School of Mudhol town of Mudhol Taluk of Bagalkote District | 4438837.28 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3592181 | 130787 | None | MDL01 | GROUND FLOOR BUILDING Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (PWD CSR 2021-22 Vol -1 P.No.8 I.No 1.14.1) In all kinds of soils Depth upto 3 m
| Cum | 76.65 | 76.65 | 174.55 | False | None | None | False | None | False | 13379.2575 | 0 | 3592182 | 130787 | None | MDL02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of achineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates
| Cum | 5466.3 | 5466.3 | 11.9135 | False | None | None | False | None | False | 65122.76505 | 0 | 3592183 | 130787 | None | MDL03 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. PWD CSR 2021-22 Volume -2 P No 7 ; I No 1.9
| Cum | 214.2 | 214.2 | 289.5198 | False | None | None | False | None | False | 62015.14116 | 0 | 3592184 | 130787 | None | MDL04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 Pg No 17. I.No 2.2.1.1
| Cum | 6739.36 | 6739.36 | 30.65 | False | None | None | False | None | False | 206561.384 | 0 | 3592185 | 130787 | None | MDL05 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 P.No 17. I.No 2.4.2 )
| Cum | 10652.88 | 10652.88 | 6.4099 | False | None | None | False | None | False | 68283.895512 | 0 | 3592186 | 130787 | None | MDL06 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 P.No 17. I.No 2.4.2 )
| Cum | 9399.6 | 9399.6 | 8.3555 | False | None | None | False | None | False | 78538.3578 | 0 | 3592187 | 130787 | None | MDL07 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 P.No 17. I.No 2.4.2 )
| Cum | 11034.87 | 11034.87 | 9.9512 | False | None | None | False | None | False | 109810.198344 | 0 | 3592188 | 130787 | None | MDL08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 P.No 17. I.No 2.5.1
| Cum | 10385.76 | 10385.76 | 21.9177 | False | None | None | False | None | False | 227631.971952 | 0 | 3592189 | 130787 | None | MDL09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 P.No 17. I.No 2.5.1
| Cum | 9736.65 | 9736.65 | 47.2536 | False | None | None | False | None | False | 460091.76444 | 0 | 3592190 | 130787 | None | MDL10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 P.No 17. I.No 2.5.1
| Cum | 9412.1 | 9412.1 | 2.128 | False | None | None | False | None | False | 20028.9488 | 0 | 3592191 | 130787 | None | MDL11 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately). (PWD CSR 2021-22 / VOLUME 3 / P. NO 71 / I NO 11.32) "
| Kg | 96.6 | 96.6 | 11342.8076 | False | None | None | False | None | False | 1095715.21416 | 0 | 3592192 | 130787 | None | MDL12 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) .PWD CSR 2021-22 Volume -2 P No 9 ; I No 5.4
| Cum | 5619.6 | 5619.6 | 64.8996 | False | None | None | False | None | False | 364709.79216 | 0 | 3592193 | 130787 | None | MDL13 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 Pg.No 15. I.No 2.1.4
| Cum | 6014.4 | 6014.4 | 19.37 | False | None | None | False | None | False | 116498.928 | 0 | 3592194 | 130787 | None | MDL14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. PWD CSR 2021-22 Volume 2 P.No-14 I.No-6.8
| Cum | 7024.5 | 7024.5 | 41.3179 | False | None | None | False | None | False | 290237.58855 | 0 | 3592195 | 130787 | None | MDL15 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD CSR 2021-22 Volume -2 P.No-41 I.No-8.1.2
| Sqm | 313.95 | 313.95 | 332.5607 | False | None | None | False | None | False | 104407.431765 | 0 | 3592196 | 130787 | None | MDL16 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR 2021-22 Volume -2 Page No-42 I.No-8.7
| Sqm | 326.55 | 326.55 | 400.601 | False | None | None | False | None | False | 130816.25655 | 0 | 3592197 | 130787 | None | MDL17 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab,including cost of materials, labour, curing, polishing complete as per specifications.(PWD Belagavi SR 2021-22 Page No.64 Item No 9.34)
| Sqm | 1251.6 | 1251.6 | 173.1173 | False | None | None | False | None | False | 216673.61268 | 0 | 3592198 | 130787 | None | MDL18 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.(PWD Belagavi SR 2021-22 Page No.64 Item No 9.34)
| Sqm | 2514.75 | 2514.75 | 120.1507 | False | None | None | False | None | False | 302148.972825 | 0 | 3592199 | 130787 | None | MDL19 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. PWD CSR 2021-22 Volume 2 P.No-100 I.No-12.12
| Cum | 79111.2 | 79111.2 | 0.6536 | False | None | None | False | None | False | 51707.08032 | 0 | 3592200 | 130787 | None | MDL20 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. PWD CSR 2021-22 Volume -2 P.No-105 I.No-12.51
| No | 1559.25 | 1559.25 | 3.0 | False | None | None | False | None | False | 4677.75 | 0 | 3592201 | 130787 | None | MDL21 | Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. PWD CSR 2021-22 Volume -2 P.No-105 I.No-12.52
| No | 1060.5 | 1060.5 | 8.0 | False | None | None | False | None | False | 8484.0 | 0 | 3592202 | 130787 | None | MDL22 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding PWD CSR 2021-22 Volume -2 P.No-85 I.No-11.34A
| Kg | 152.25 | 152.25 | 302.4 | False | None | None | False | None | False | 46040.4 | 0 | 3592203 | 130787 | None | MDL23 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) PWD CSR 2021-22 Volume -2 P.No-100 I.No-12.15
| Sqm | 5327.7 | 5327.7 | 7.56 | False | None | None | False | None | False | 40277.412 | 0 | 3592204 | 130787 | None | MDL24 | Providing and fixing in position Honnewood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) PWD CSR 2021-22 Volume -2 P.No-101 I.No-12.23
| Sqm | 5441.1 | 5441.1 | 14.4 | False | None | None | False | None | False | 78351.84 | 0 | 3592205 | 130787 | None | MDL25 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge PWD CSR 2021-22 Volume -2 P.No-50 I.No-8.51
| Sqm | 87.15 | 87.15 | 646.5201 | False | None | None | False | None | False | 56344.226715 | 0 | 3592206 | 130787 | None | MDL26 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CSR 2021-22 Volume 2 P.No-45 / I.No-8.25
| Sqm | 110.25 | 110.25 | 646.5201 | False | None | None | False | None | False | 71278.841025 | 0 | 3592207 | 130787 | None | MDL27 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CSR 2021-22 Vol -2 P.No-46 I.No-8.30
| Sqm | 142.8 | 142.8 | 332.5607 | False | None | None | False | None | False | 47489.66796 | 0 | 3592208 | 130787 | None | MDL28 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.PWD CSR 2021-22 Vol -2 P.No- 48 I.No-8.40
| Sqm | 94.5 | 94.5 | 112.464 | False | None | None | False | None | False | 10627.848 | 0 | 3592209 | 130787 | None | MDL29 | PVC Pipe 110mm Outer Dia at 2 kg Per Sqcm. PWD CSR 2021-22 Vol -3 P.No- M -056a) I.No- A-11
| Rmtr | 159.6 | 159.6 | 6.0 | False | None | None | False | None | False | 957.6 | 0 | 3592210 | 130787 | None | MDL30 | Providing and fixing 12 m thick flat pressed 3 layer medium density particle board or graded particle board (Grade I) IS:3087 marked, in ceiling with necessary nails etc.complete.PWD CSR 2021-22 Vol -2 P.No- 23 I.No-7.24
| Sqm | 681.45 | 681.45 | 2.0 | False | None | None | False | None | False | 1362.9 | 0 | 3592211 | 130787 | None | MDL31 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. E.R.W. tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-Charge.(PWD CSR 2021-22 Vol -2, P No.82 I No 11.26.2 )
| Kg | 121.8 | 121.8 | 336.798 | False | None | None | False | None | False | 41021.9964 | 0 | 3592212 | 130787 | None | MDL32 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.PWD CSR 2021-22 Vol -2 1stcorr
| Sqm | 1262.1 | 1262.1 | 10.152 | False | None | None | False | None | False | 12812.8392 | 0 | 3592213 | 130787 | None | MDL33 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement,stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specificationsand as per directions of the Engineer-in-ChargePWD CSR 2021-22 Volume -2 P.No 75. I.No 11.3
| Sqm | 6891.15 | 6891.15 | 5.04 | False | None | None | False | None | False | 34731.396 | 0 |
| 1721736463000 | 1 | None | None | Buildings | First Floor Building Construction of Seven Class rooms to Jai Hind No-1 Government Higher Primary School of Mudhol town of Mudhol Taluk of Bagalkote District | 3662026.43 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3592214 | 130788 | None | MDL34 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 P.No 17. I.No 2.5.1
| Cum | 11037.96 | 11037.96 | 9.9512 | False | None | None | False | None | False | 109840.947552 | 0 | 3592215 | 130788 | None | MDL35 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 P.No 17. I.No 2.5.1
| Cum | 10388.85 | 10388.85 | 17.4098 | False | None | None | False | None | False | 180867.80073 | 0 | 3592216 | 130788 | None | MDL36 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 P.No 17. I.No 2.5.1
| Cum | 9739.74 | 9739.74 | 49.05 | False | None | None | False | None | False | 477734.247 | 0 | 3592217 | 130788 | None | MDL37 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2021-22 Volume -1 P.No 17. I.No 2.5.1
| Cum | 9415.19 | 9415.19 | 1.9468 | False | None | None | False | None | False | 18329.491892 | 0 | 3592218 | 130788 | None | MDL38 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately). (PWD CSR 2021-22 / VOLUME 3 / P. NO 71 / I NO 11.32)
| Kg | 97.56 | 97.56 | 7049.083 | False | None | None | False | None | False | 687708.53748 | 0 | 3592219 | 130788 | None | MDL39 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. PWD CSR 2021-22 Volume 2 P.No-14 I.No-6.8
| Cum | 7091.4 | 7091.4 | 94.84 | False | None | None | False | None | False | 672548.376 | 0 | 3592220 | 130788 | None | MDL40 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD CSR 2021-22 Volume -2 P.No-41 I.No-8.1.2
| Sqm | 316.94 | 316.94 | 474.511 | False | None | None | False | None | False | 150391.51634 | 0 | 3592221 | 130788 | None | MDL41 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD CSR 2021-22 Volume -2 Page No-42 I.No-8.7
| Sqm | 329.66 | 329.66 | 366.792 | False | None | None | False | None | False | 120916.65072 | 0 | 3592222 | 130788 | None | MDL42 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab,including cost of materials, labour, curing, polishing complete as per specifications.(PWD Belagavi SR 2021-22 Page No.64 Item No 9.34
| Sqm | 1263.52 | 1263.52 | 193.8445 | False | None | None | False | None | False | 244926.40264 | 0 | 3592223 | 130788 | None | MDL43 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.(PWD Belagavi SR 2021-22 Page No.64 Item No 9.34)
| Sqm | 2538.7 | 2538.7 | 80.767 | False | None | None | False | None | False | 205043.1829 | 0 | 3592224 | 130788 | None | MDL44 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. PWD CSR 2021-22 Volume 2 P.No-100 I.No-12.12
| Cum | 79111.2 | 79111.2 | 1.845 | False | None | None | False | None | False | 145960.164 | 0 | 3592225 | 130788 | None | MDL45 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. PWD CSR 2021-22 Volume -2 P.No-105 I.No-12.51
| No | 1559.25 | 1559.25 | 5.0 | False | None | None | False | None | False | 7796.25 | 0 | 3592226 | 130788 | None | MDL46 | Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. PWD CSR 2021-22 Volume -2 P.No-105 I.No-12.52
| No | 1060.5 | 1060.5 | 21.0 | False | None | None | False | None | False | 22270.5 | 0 | 3592227 | 130788 | None | MDL47 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding PWD CSR 2021-22 Volume -2 P.No-85 I.No-11.34A
| Kg | 153.7 | 153.7 | 793.8 | False | None | None | False | None | False | 122007.06 | 0 | 3592228 | 130788 | None | MDL48 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) PWD CSR 2021-22 Volume -2 P.No-100 I.No-12.15
| Sqm | 5327.7 | 5327.7 | 12.6 | False | None | None | False | None | False | 67129.02 | 0 | 3592229 | 130788 | None | MDL49 | Providing and fixing in position Honnewood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) PWD CSR 2021-22 Volume -2 P.No-101 I.No-12.23
| Sqm | 5441.1 | 5441.1 | 37.8 | False | None | None | False | None | False | 205673.58 | 0 | 3592230 | 130788 | None | MDL50 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge PWD CSR 2021-22 Volume -2 P.No-50 I.No-8.51
| Sqm | 87.98 | 87.98 | 632.6935 | False | None | None | False | None | False | 55664.37413 | 0 | 3592231 | 130788 | None | MDL51 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CSR 2021-22 Volume 2 P.No-45 / I.No-8.25
| Sqm | 111.3 | 111.3 | 632.6935 | False | None | None | False | None | False | 70418.78655 | 0 | 3592232 | 130788 | None | MDL52 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. PWD CSR 2021-22 Vol -2 P.No-46 I.No-8.30
| Sqm | 144.16 | 144.16 | 474.511 | False | None | None | False | None | False | 68405.50576 | 0 | 3592233 | 130788 | None | MDL53 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-harge.PWD CSR 2021-22 Vol -2 P.No- 48 I.No-8.40
| Sqm | 95.4 | 95.4 | 110.88 | False | None | None | False | None | False | 10577.952 | 0 | 3592234 | 130788 | None | MDL54 | PVC Pipe 110mm Outer Dia at 2 kg Per Sqcm. PWD CSR 2021-22 Vol -3 P.No- M -056a) I.No- A-11
| Rmtr | 159.6 | 159.6 | 10.0 | False | None | None | False | None | False | 1596.0 | 0 | 3592235 | 130788 | None | MDL55 | Providing and fixing 12 m thick flat pressed 3 layer medium density particle board or graded particle board (Grade I) IS:3087 marked, in ceiling with necessary nails etc.complete.PWD CSR 2021-22 Vol -2 P.No- 23 I.No-7.24
| Sqm | 681.45 | 681.45 | 5.0 | False | None | None | False | None | False | 3407.25 | 0 | 3592236 | 130788 | None | MDL56 | Providing Lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20cms c to c both horizontally and vertically fixed with chicken mesh, for drops chajja ,facia, backing to cup boards including cost of materials, labour, providing and removing form work usage charges, curing complete as per specifications. PWD CSR 2021-22 Volume -2 P.No- 41 I.No-8.83
| Sqm | 1262.1 | 1262.1 | 10.152 | False | None | None | False | None | False | 12812.8392 | 0 |
| 1721736463000 | 0 | None | None | Buildings | Electrical Construction of Seven Class rooms to Jai Hind No-1 Government Higher Primary School of Mudhol town of Mudhol Taluk of Bagalkote District | 121888.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3592237 | 130789 | None | MDL57 | Supplying heavy gauge PVC Conduit Pipe 25 mm dia 2 mm thick with suitable size bends metal junction boxes adhesive paste etc by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary | Mtr | 70.0 | 70.0 | 300.0 | False | None | None | False | None | False | 21000.0 | 0 | 3592238 | 130789 | None | MDL58 | Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 2x1.5 sqmm (Phase and Neutral) and 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block complete for each outlet do Short point up to 3mtr from tapping point to out let via Switch | Point | 276.0 | 276.0 | 20.0 | False | None | None | False | None | False | 5520.0 | 0 | 3592239 | 130789 | None | MDL59 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. -do- Short point upto 3Mtr from tapping point to out let via switch (PWD Common Schedule of Rate 2021-22 (Elct) SR Pg.No.2 It.No.2.1.1 )b) Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 276.0 | 276.0 | 20.0 | False | None | None | False | None | False | 5520.0 | 0 | 3592240 | 130789 | None | MDL60 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. -do- Short point upto 3Mtr from tapping point to out let via switch c) Long point above 6Mtr upto 10Mtr from tapping point to out let via switch ((PWD Common Schedule of Rate 2021-22 (Elct) SR Pg.No.3 It.No.2.1.3 )
| Point | 276.0 | 276.0 | 10.0 | False | None | None | False | None | False | 2760.0 | 0 | 3592241 | 130789 | None | MDL61 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. -do- 1.5 sqmm | Mtr | 26.0 | 26.0 | 420.0 | False | None | None | False | None | False | 10920.0 | 0 | 3592242 | 130789 | None | MDL62 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 -do- 6Amps 3/5 Way | Each | 143.0 | 143.0 | 20.0 | False | None | None | False | None | False | 2860.0 | 0 | 3592243 | 130789 | None | MDL63 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.-6Amps SP Switch | Each | 43.0 | 43.0 | 80.0 | False | None | None | False | None | False | 3440.0 | 0 | 3592244 | 130789 | None | MDL64 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board.32A Bakelite DP | Each | 200.0 | 200.0 | 8.0 | False | None | None | False | None | False | 1600.0 | 0 | 3592245 | 130789 | None | MDL65 | Supplying and fixing PBBC/Bakelite straight or slant batten holder and wiring with 60w/230 volts lamps.6A Lamp Holder | Each | 63.0 | 63.0 | 30.0 | False | None | None | False | None | False | 1890.0 | 0 | 3592246 | 130789 | None | MDL66 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator. | Each | 313.0 | 313.0 | 12.0 | False | None | None | False | None | False | 3756.0 | 0 | 3592247 | 130789 | None | MDL67 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. -do- 48" Sweep (1200mm) Regular model | Each | 2085.0 | 2085.0 | 22.0 | False | None | None | False | None | False | 45870.0 | 0 | 3592248 | 130789 | None | MDL68 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. -do- On wall / ceiling / Rafter / Girders | Each | 119.0 | 119.0 | 50.0 | False | None | None | False | None | False | 5950.0 | 0 | 3592249 | 130789 | None | MDL69 | Fixing a ceilling wall mounting fan of all capacities and all types of the existingS hook with fan regulator to the existing board together with supplying and fixing5ampsceillingrosenecessarylengthof23/0.0076inchPVCinsulatedtwintwistedcopper wire and wiring | Each | 162.0 | 162.0 | 22.0 | False | None | None | False | None | False | 3564.0 | 0 | 3592250 | 130789 | None | MDL70 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. -do- 6-32Amps DPPWD Common Schedule of Rate 2021-22 (Elct) SR Pg.No.13 It.No.5.17.4 )
| Each | 1103.0 | 1103.0 | 4.0 | False | None | None | False | None | False | 4412.0 | 0 | 3592251 | 130789 | None | MDL71 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. -do- 32-40 Amps 4 pole (PWD Common Schedule of Rate 2021-22 (Elct) SR Pg.No.13 It.No.5.20.3 ) | Each | 2826.0 | 2826.0 | 1.0 | False | None | None | False | None | False | 2826.0 | 0 |
|
|
---|