| 1717655520000 | 3 | None | None | Buildings | CONSTRUCTION OF COMMUNITY TOILET ATTACHED TO BURIAL GROUND COMPOUND WALL IN W.NO19 NEAR NAVALGUND BEPARI HOUSE AT NAREGAL TOWN | 1056598.95 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3234686 | 111802 | None | PWD Comman SR 2023-24, Item no. 1.17.1, Page No.10 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. | Cum | 269.86 | 269.86 | 25.42 | False | 0.0 | 0.0 | False | None | False | 6859.8412 | 0 | | 3234687 | 111802 | None | PWD SR Vol-01, 2023-24, Item no. 2.1.2, Page No.15 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5833.92 | 5833.92 | 7.31 | False | 0.0 | 0.0 | False | None | False | 42645.9552 | 0 | | 3234688 | 111802 | None | PWD SR Vol-02, 2023-24, Item no.6.34, Page No.17 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD SR Vol-02, 2023-24, Item no.6.34, Page No.17) | Cum | 1137.12 | 1137.12 | 11.02 | False | 0.0 | 0.0 | False | None | False | 12531.0624 | 0 | | 3234689 | 111802 | None | PWD Vol-1 SR 2023-24, Item no. 1.10, Page No.7 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. (PWD Vol-1 SR 2023-24,Item no. 1.10, Page No.7 | Cum | 164.8 | 164.8 | 40.55 | False | 0.0 | 0.0 | False | None | False | 6682.64 | 0 | | 3234690 | 111802 | None | PWD Vol-1 SR 2023-24, Item No. 2.11a, Page No. 18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (PWD Vol-1 SR 2023-24, Item No. 2.11a, Page No. 18) | Tonne | 92140.71 | 92140.71 | 0.76 | False | 0.0 | 0.0 | False | None | False | 70026.9396 | 0 | | 3234691 | 111802 | None | PWD Vol-02 SR 2023-24, Item no. 6.7, Page No.13 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (PWD Vol-02 SR 2023-24, Item no. 6.7, Page No.13) | Cum | 8457.33 | 8457.33 | 26.63 | False | 0.0 | 0.0 | False | None | False | 225218.6979 | 0 | | 3234692 | 111802 | None | PWD SR, Vol.1, 2023-24, Item no. 2.5.2, Page No.16 | Providing and laying in position Cement Concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, Vol.1, 2023-24, Item no. 2.5.2, Page No.16) | Cum | 11154.09 | 11154.09 | 12.09 | False | 0.0 | 0.0 | False | None | False | 134852.9481 | 0 | | 3234693 | 111802 | None | PWD SR, Vol.1, 2023-24, Item no. 2.5.2, Page No.16 | Providing and laying in position Cement Concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, Vol.1, 2023-24, Item no. 2.5.2, Page No.16) | Cum | 10469.79 | 10469.79 | 1.4 | False | 0.0 | 0.0 | False | None | False | 14657.706 | 0 | | 3234694 | 111802 | None | PWD SR Vol-02, 2023-24, Item no. 8.4.1, Page No.41 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-02, 2023-24, Item no. 8.4.1, Page No.41) | Sqm | 332.69 | 332.69 | 107.28 | False | 0.0 | 0.0 | False | None | False | 35690.9832 | 0 | | 3234695 | 111802 | None | PWD SR Vol-02, 2023-24, Item no. 8.9, Page No.42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-02, 2023-24, Item no. 8.9, Page No.42) | Sqm | 396.55 | 396.55 | 92.44 | False | 0.0 | 0.0 | False | None | False | 36657.082 | 0 | | 3234696 | 111802 | None | PWD SR Vol-02, 2023-24, Item no. 9.11, Page No.60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (PWD SR Vol-02, 2023-24, Item no. 9.11, Page No.60) | Sqm | 915.67 | 915.67 | 36.02 | False | 0.0 | 0.0 | False | None | False | 32982.4334 | 0 | | 3234697 | 111802 | None | PWD SR Vol-02, 2023-24, Item no. 9.39, Page No.65 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (PWD SR Vol-02, 2023-24, Item no. 9.39, Page No.65) | Sqm | 1492.47 | 1492.47 | 34.23 | False | 0.0 | 0.0 | False | None | False | 51087.2481 | 0 | | 3234698 | 111802 | None | PWD SR Vol-02, 2023-24, Item no. 11.4, Page No.77 | Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR Vol-02, 2023-24, Item no. 11.4, Page No.77) | Sqm | 5377.63 | 5377.63 | 5.25 | False | 0.0 | 0.0 | False | None | False | 28232.5575 | 0 | | 3234699 | 111802 | None | PWD SR Vol-02, 2023-24, Item no. 12.53, Page N.104 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to
the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges. (PWD SR Vol-02, 2023-24, Item no. 12.53, Page No.104) | Sqm | 1635.64 | 1635.64 | 12.6 | False | 0.0 | 0.0 | False | None | False | 20609.064 | 0 | | 3234700 | 111802 | None | PWD SR Vol-02, 2023-24, Item no. 11.34B, Page N.86 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (PWD SR Vol-02, 2023-24, Item no. 11.34B, Page No.86) | Kg | 188.49 | 188.49 | 328.32 | False | 0.0 | 0.0 | False | None | False | 61885.0368 | 0 | | 3234701 | 111802 | None | PWD SR Vol-02, 2023-24, Item no. 11.16.1,Page N.81 | 1 Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR Vol-02, 2023-24, Item no. 11.16.1, Page No.81) | Kg | 143.17 | 143.17 | 546.36 | False | 0.0 | 0.0 | False | None | False | 78222.3612 | 0 | | 3234702 | 111802 | None | PWD SR Vol-02, 2023-24, Item no. 7.1.1, Page No.21 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. (PWD SR Vol-02, 2023-24, Item no. 7.1.1, Page No.21) | Sqm | 905.37 | 905.37 | 86.8 | True | 86.8 | 86.8 | False | None | False | 78586.116 | 0 | | 3234703 | 111802 | None | PWD SR Vol-02, 2023-24, Item no. 12.85, Page N.109 | Providing & fixing of louvered ventilator made out of multi chambered UPVC Matching to RAL-9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium powder coated in whitewill be us | Sqm | 5890.87 | 5890.87 | 1.08 | False | 0.0 | 0.0 | False | None | False | 6362.1396 | 0 | | 3234704 | 111802 | None | PWD SR Vol-02, 2023-24, Item no. 8.33.1, Page N.46 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree
angle with 10 years life) (PWD SR Vol-02, 2023-24, Item no. 8.33.1, Page No.46) | Sqm | 162.74 | 162.74 | 76.69 | False | 0.0 | 0.0 | False | None | False | 12480.5306 | 0 | | 3234705 | 111802 | None | PWD SR Vol-02, 2023-24, Item no. 14.3.1, PageN.131 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid. (PWD SR Vol-02, 2023-24, Item no. 14.3.1, Page No.131) | Each | 6156.31 | 6156.31 | 2.0 | False | 0.0 | 0.0 | False | None | False | 12312.62 | 0 | | 3234706 | 111802 | None | PWD SR Vol-02, 2023-24, Item no. 14.1.1, PagNo.131 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (PWD SR Vol-02, 2023-24, Item no. 14.1.1, Page No.131) | Each | 5030.52 | 5030.52 | 5.0 | False | 0.0 | 0.0 | False | None | False | 25152.6 | 0 | | 3234707 | 111802 | None | PWD SR Vol-02, 2023-24, Item no. 14.7A, Page N.133 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. (PWD SR Vol-02, 2023-24, Item no. 14.7A, Page No.133) | Each | 4244.63 | 4244.63 | 1.0 | False | 0.0 | 0.0 | False | None | False | 4244.63 | 0 | | 3234708 | 111802 | None | PWD SR Vol-05, 2021-22, Sl no. 1.2, M010B, P.N134 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testingand commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 32mm dia., 10 kg/sqcm & class 5. (PWD SR Vol-05, 2021-22, Sl no. 1.2, M010B, Page No.134) | Mtr | 65.92 | 65.92 | 30.0 | False | 0.0 | 0.0 | False | None | False | 1977.6 | 0 | | 3234709 | 111802 | None | PWD SR Vol-05, 2021-22, Sl no. 6.2, M090B, P.N136 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments.32mm dia PVC couplers, (PWD SR Vol-05, 2021-22, Sl no. 6.2, M090B, Page No.136) | Each | 17.51 | 17.51 | 8.0 | False | 0.0 | 0.0 | False | None | False | 140.08 | 0 | | 3234710 | 111802 | None | PWD SR Vol-05, 2021-22, Sl no. 7.2, M100B, P.No137 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.32 mm dia PVC Elbows. (PWD SR Vol-05, 2021-22, Sl no. 7.2, M100B, Page No.137) | Each | 22.66 | 22.66 | 8.0 | False | 0.0 | 0.0 | False | None | False | 181.28 | 0 | | 3234711 | 111802 | None | PWD SR Vol-05, 2021-22, Sl no. 9.2, M120B, P.No138 | Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.32 mm dia PVC BEND. (PWD SR Vol-05, 2021-22, Sl no. 9.2, M120B, Page No.138) | Each | 39.14 | 39.14 | 8.0 | False | 0.0 | 0.0 | False | None | False | 313.12 | 0 | | 3234712 | 111802 | None | PWD SR Vol-02, 2023-24, Sl no. 13.34A, Page No.123 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.(For 1000 litre capacity) (PWD SR Vol-02, 2023-24, Sl no. 13.34A, Page No.123) | Ltr | 9.27 | 9.27 | 1000.0 | False | 0.0 | 0.0 | False | None | False | 9270.0 | 0 | | 3234713 | 111802 | None | PWD SR Vol-02, 2023-24, ltem no.13.4.2, Page N.117 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore. (PWD SR Vol-02, 2023-24, ltem no.13.4.2, Page No.117) | Nos | 615.94 | 615.94 | 7.0 | False | 0.0 | 0.0 | False | None | False | 4311.58 | 0 | | 3234714 | 111802 | None | PWD SR Vol-02, 2023-24, ltem no.13.3.2, Page N117 | Providing and fixing brass stop cock of approved quality : 20 mm nominal bore. ( | Each | 314.15 | 314.15 | 7.0 | False | 0.0 | 0.0 | False | None | False | 2199.05 | 0 | | 3234715 | 111802 | None | PWD SR Vol-02, 2023-24, ltem no.13.2.2, Page N117 | Providing and fixing brass bib cock of approved quality.20 mm nominal bore. (PWD SR Vol-02, 2023-24, ltem no.13.2.2, Page No.117) | Each | 314.15 | 314.15 | 7.0 | False | 0.0 | 0.0 | False | None | False | 2199.05 | 0 | | 3234716 | 111802 | None | PWD Electrical CSR 2023-24, IN-1.2.1, PN-2 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, 19/20 mm dia 2 mm thick, (PWD Electrical CSR 2023-24, IN-1.2.1, PN-2) | Mtr | 66.0 | 66.0 | 25.0 | False | 0.0 | 0.0 | False | None | False | 1650.0 | 0 | | 3234717 | 111802 | None | PWD Electrical CSR 2023-24, IN-1.3.2, PN-2 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick (PWD Electrical CSR 2023-24, IN-1.3.2, PN-2) | Mtr | 79.0 | 79.0 | 25.0 | False | 0.0 | 0.0 | False | None | False | 1975.0 | 0 | | 3234718 | 111802 | None | PWD Electrical CSR 2021-2022, IN-2.2.1, PN-5 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2021-2022, IN-2.2.1, PN-5), Short point upto 3m from tapping point to out let via switch box. | Mtr | 269.0 | 269.0 | 2.0 | False | 0.0 | 0.0 | False | None | False | 538.0 | 0 | | 3234719 | 111802 | None | PWD Electrical CSR 2023-24, IN-2.2.2, PN-5 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2023-24, IN-2.2.2, PN-5), Medium point above 3m upto 6m from tapping point to out let via switch box. | Point | 379.0 | 379.0 | 4.0 | False | 0.0 | 0.0 | False | None | False | 1516.0 | 0 | | 3234720 | 111802 | None | PWD Electrical CSR 2023-24, IN-2.2.2, PN-5 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2023-24, IN-2.2.2, PN-5), Long point above 6m upto 10m from tapping point to out let via switch box | Point | 379.0 | 379.0 | 20.0 | False | 0.0 | 0.0 | False | None | False | 7580.0 | 0 | | 3234721 | 111802 | None | PWD Electrical CSR 2023-24, IN-2.3.2, PN-5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.PWD Electrical CSR 2023-24, IN-2.3.2, PN-5), 1.5 mm2 | Mtr | 26.0 | 26.0 | 20.0 | False | 0.0 | 0.0 | False | None | False | 520.0 | 0 | | 3234722 | 111802 | None | PWD Electrical CSR 2023-24, IN-2.3.4, PN-5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments. (PWD Electrical CSR 2023-24, IN-2.3.4, PN-5), 4 mm2 | Mtr | 63.0 | 63.0 | 20.0 | False | 0.0 | 0.0 | False | None | False | 1260.0 | 0 | | 3234723 | 111802 | None | PWD Electrical CSR 2023-24, IN-3.1.2, PN-8 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654, (PWD Electrical CSR 2023-24, IN-3.1.2, PN-8), 6A 3/5 Way | Each | 147.0 | 147.0 | 4.0 | False | 0.0 | 0.0 | False | None | False | 588.0 | 0 | | 3234724 | 111802 | None | PWD Electrical CSR 2023-24, IN-3.4.3, PN-8 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall,6 Way | Each | 177.0 | 177.0 | 2.0 | False | 0.0 | 0.0 | False | None | False | 354.0 | 0 | | 3234725 | 111802 | None | PWD Electrical CSR 2023-24, IN-3.4.6, PN-8 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16-18 Way | Each | 319.0 | 319.0 | 2.0 | False | 0.0 | 0.0 | False | None | False | 638.0 | 0 | | 3234726 | 111802 | None | PWD Electrical CSR 2023-24, IN-3.5.3, PN-8 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box, (PWD Electrical CSR 2023-24, IN-3.5.3, PN-8), 6 Module | Each | 175.0 | 175.0 | 2.0 | False | 0.0 | 0.0 | False | None | False | 350.0 | 0 | | 3234727 | 111802 | None | PWD Electrical CSR 2023-24, IN-3.5.7, PN-8 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box, (PWD Electrical CSR 2023-24, IN-3.5.7, PN-8), 16 Module | Each | 397.0 | 397.0 | 2.0 | False | 0.0 | 0.0 | False | None | False | 794.0 | 0 | | 3234728 | 111802 | None | PWD Electrical CSR 2023-24, IN-11.3.1, PN-43 | Supplying of .feet -PVC Batten with integrated LED tube .defect working under standard electrical condition.LED light fitting 1 x 2' - 9/10 W | Each | 551.0 | 551.0 | 4.0 | False | 0.0 | 0.0 | False | None | False | 2204.0 | 0 | | 3234729 | 111802 | None | PWD Electrical CSR 2023-24, IN-11.4.2, PN-44 | Supplying of recess mounting non integrated type LED down light.luminaire working under standard electrical condition.10-12W | Each | 1269.0 | 1269.0 | 4.0 | False | 0.0 | 0.0 | False | None | False | 5076.0 | 0 | | 3234730 | 111802 | None | PWD Electrical CSR 2023-24, IN-5.18.4, PN-17 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. (PWD Electrical CSR 2023-24, IN-5.18.4, PN-17).6-32 A DP | Each | 739.0 | 739.0 | 1.0 | False | 0.0 | 0.0 | False | None | False | 739.0 | 0 | | 3234731 | 111802 | None | PWD Electrical CSR 2023-24, IN-5.42.2, PN-20 | Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. (PWD Electrical CSR 2023-24, IN-5.42.2, PN-20).16SWG. | Sq CM | 0.43 | 0.43 | 8000.0 | False | 0.0 | 0.0 | False | None | False | 3440.0 | 0 | | 3234732 | 111802 | None | PWD Electrical CSR 2023-24, IN-5.40.1, PN-20 | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. (PWD Electrical CSR 2023-24, IN-5.40.1, PN-20).100 A 4 x 30 x 6 mm Aluminium Strips | Mtr | 2465.0 | 2465.0 | 1.0 | False | 0.0 | 0.0 | False | None | False | 2465.0 | 0 | | 3234733 | 111802 | None | PWD Electrical CSR 2023-24, IN-5.30, PN-19 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter (PWD Electrical CSR 2023-24, IN-5.30, PN-19) | Each | 1380.0 | 1380.0 | 1.0 | False | 0.0 | 0.0 | False | None | False | 1380.0 | 0 | | 3234734 | 111802 | None | Bescom CSR 2021-22, IN-35.01, PN-15 | Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable, (Bescom CSR 2021-22, IN-35.01, PN-15), Up to 4C x 50 Sqmm | Set | 324.0 | 324.0 | 1.0 | False | 0.0 | 0.0 | False | None | False | 324.0 | 0 | | 3234735 | 111802 | None | PWD SR Vol-05, 2021-22, Sl No.50, CODE:P480A,165 | Supply, delivery, erection and commissioning at site lighting distribution board suitable for monoblock centrifugal pump confirming with ISI mark and its latest amendments. (PWD SR Vol-05, 2021-22, Sl No.50, CODE:P480A, Page No.165) | Set | 4635.0 | 4635.0 | 1.0 | False | 0.0 | 0.0 | False | None | False | 4635.0 | 0 |
|