| 1721892217000 | 0 | None | None | Buildings | Construction of 2 Community Toilet at ward no. 25 and I community toilet near DFA Quarters at ward no.12 and maintenance of other toilets | 802543.91 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3617312 | 131409 | None | Volume I,I No 1.4 2023-24 SR, PWD S R DWR Circle | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. | Cum | 249.0 | 249.0 | 39.56 | False | None | None | False | None | False | 9850.44 | 0 | | 3617313 | 131409 | None | Volume I,I No 2.1.4 2023-24 SR, PWD S R DWR Circle | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarseaggregates | Cum | 6403.51 | 6403.51 | 2.36 | False | None | None | False | None | False | 15112.2836 | 0 | | 3617314 | 131409 | None | Volume I, I No 2.1.4 2023-24 SR, PWD S R DWR Circl | Providing and laying in position Mix 1:3:6 Using 20 mm and down size graded crushed coarse aggregates. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately | Cum | 6403.51 | 6403.51 | 1.24 | False | None | None | False | None | False | 7940.3524 | 0 | | 3617315 | 131409 | None | Volume II,I No 5.2, 2023-24 SR, PWD S R DWR Circle | Providing Coursed rubble masonry with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand | Cum | 6816.54 | 6816.54 | 8.18 | False | None | None | False | None | False | 55759.2972 | 0 | | 3617316 | 131409 | None | Volume I,I No 2.2.1, 2023-24 SR, PWD S R DWR Circl | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. | Cum | 10360.98 | 10360.98 | 1.72 | False | None | None | False | None | False | 17820.8856 | 0 | | 3617317 | 131409 | None | Volume I,I No 2.2.1, 2023-24 SR, PWD S R DWR Circl | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications | Cum | 9713.42 | 9713.42 | 4.86 | False | None | None | False | None | False | 47207.2212 | 0 | | 3617318 | 131409 | None | Volume I,I No 2.2.1, 2023-24 SR, PWD S R DWR Circl | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications | Cum | 8742.07 | 8742.07 | 5.42 | False | None | None | False | None | False | 47382.0194 | 0 | | 3617319 | 131409 | None | Volume I,I No 1.9, 2023-24 SR, PWD S R DWR Circle | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 5.46 | False | None | None | False | None | False | 1495.9308 | 0 | | 3617320 | 131409 | None | Volume II I No 11.34A , 2023-24 SR PWD S R DWR Cir | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 173.04 | 173.04 | 30.24 | False | None | None | False | None | False | 5232.7296 | 0 | | 3617321 | 131409 | None | Volume I , I No 12.85, 2023-24 SR, PWD S R DWR Cir | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made | Sqm | 5890.57 | 5890.57 | 1.44 | False | None | None | False | None | False | 8482.4208 | 0 | | 3617322 | 131409 | None | Volume I , I No 12.85, 2023-24 SR, PWD S R DWR Cir | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification | t | 92140.71 | 92140.71 | 0.73 | False | None | None | False | None | False | 67262.7183 | 0 | | 3617323 | 131409 | None | Volume II , I No 9.9 2023-24 SR, PWD S R DWR Circl | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 includ ing pointing the joints with white cement and matching pigment etc., complete | Sqm | 1108.28 | 1108.28 | 29.16 | False | None | None | False | None | False | 32317.4448 | 0 | | 3617324 | 131409 | None | Volume II , I No 9.38 2023-24 SR, PWD S R DWR Circ | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications | Sqm | 1559.04 | 1559.04 | 37.56 | False | None | None | False | None | False | 58557.5424 | 0 | | 3617325 | 131409 | None | Volume II, I No 6.33 2023-24 SR, PWD S R DWR Circl | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1267.93 | 1267.93 | 102.5 | False | None | None | False | None | False | 129962.825 | 0 | | 3617326 | 131409 | None | Volume II, I No 6.13 2023-24 SR, PWD S R DWR Circl | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 1005.28 | 1005.28 | 24.6 | False | None | None | False | None | False | 24729.888 | 0 | | 3617327 | 131409 | None | Volume II , I No 8.1.2, 2023-24 SR PWD S R DWR | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 248.23 | 248.23 | 25.16 | False | None | None | False | None | False | 6245.4668 | 0 | | 3617328 | 131409 | None | Volume II , I No 8.2.2, 2023-24 SR PWD S R DWR | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 287.37 | 287.37 | 72.39 | False | None | None | False | None | False | 20802.7143 | 0 | | 3617329 | 131409 | None | Volume II , I No 8.3.2, 2023-24 SR PWD S R DWR | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directionsof Engineer-in-charge | Sqm | 342.99 | 342.99 | 148.54 | False | None | None | False | None | False | 50947.7346 | 0 | | 3617330 | 131409 | None | Volume II , I No 8.33.1 , 2023-24 SR | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 162.74 | 162.74 | 190.92 | False | None | None | False | None | False | 31070.3208 | 0 | | 3617331 | 131409 | None | Volume II , I No 13.51, 2023-24 SR, PWD S R DWR | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in
cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone
aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay (non modular) bricks of class designation 3.5 | Nos | 1757.18 | 1757.18 | 2.0 | False | None | None | False | None | False | 3514.36 | 0 | | 3617332 | 131409 | None | Volume II , I No 13.50.3, 2023-24 SR, PWD S R | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work | m | 230.72 | 230.72 | 24.0 | False | None | None | False | None | False | 5537.28 | 0 | | 3617333 | 131409 | None | Volume II , I No 13.64.2, 2023-24 SR, PWD S R DWR | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of
Engineer in Charge | m | 791.04 | 791.04 | 12.0 | False | None | None | False | None | False | 9492.48 | 0 | | 3617334 | 131409 | None | Volume II , I No 14.2.1, 2023-24 SR, PWD S R DWR | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required | Each | 4983.14 | 4983.14 | 8.0 | False | None | None | False | None | False | 39865.12 | 0 | | 3617335 | 131409 | None | Volume II , I No 13.59, 2023-24 SR, PWD S R DWR | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete | Each | 226.6 | 226.6 | 8.0 | False | None | None | False | None | False | 1812.8 | 0 | | 3617336 | 131409 | None | Volume II , I No 14.5.1, 2023-24 SR, PWD S R DWR | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required | Each | 8901.26 | 8901.26 | 4.0 | False | None | None | False | None | False | 35605.04 | 0 | | 3617337 | 131409 | None | Volume II , Sl No 163, 2023-24 SR, PWD S R DWR | C.P. Brass bibcock 15 mm | Each | 463.5 | 463.5 | 8.0 | False | None | None | False | None | False | 3708.0 | 0 | | 3617338 | 131409 | None | Volume II ,Item No 14.17.1 Sl No 163, 2023-24 SR, | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 3174.46 | 3174.46 | 4.0 | False | None | None | False | None | False | 12697.84 | 0 | | 3617339 | 131409 | None | Volume II , I No 12.54, 2023-24 SR, PWD S R DWR | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | m | 327.54 | 327.54 | 40.8 | False | None | None | False | None | False | 13363.632 | 0 | | 3617340 | 131409 | None | Volume II , I No 12.94.1, 2023-24 SR, PWD | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and
resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost ofmaterials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately | Sqm | 3589.55 | 3589.55 | 10.8 | False | None | None | False | None | False | 38767.14 | 0 |
|