createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721887941242
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd4173000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose26-08-2024 16:00:00
tenderQueryClose17-08-2024 16:00:00
technicalBidOpen27-08-2024 16:30:00
publishedDate25-07-2024 12:46:48
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate19-08-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonAssistant Engineer
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9449843375
tenderSupplierListNone
tenderSchedule
createdTs1721887941274
version7
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT540
titleConstruction of Primary Health Centers (H Type) at 1) Yadalapur, 2) Sagamakunta in Raichur Taluk, 3) Gouduru, 4) Mavinabhavi, 5) Nagalapura in Lingasuguru Taluk, 6) Bagalwada, 7) Mallat, 8) Rajalabanda in Manvi Taluk, 9) Mustoor, 10) Alkod, 11) Kothadoddi in Devdurga Taluk and (12) Gunda in Sindanur Taluk of Raichur District.
descriptionConstruction of Primary Health Centers (H Type) at 1) Yadalapur, 2) Sagamakunta in Raichur Taluk, 3) Gouduru, 4) Mavinabhavi, 5) Nagalapura in Lingasuguru Taluk, 6) Bagalwada, 7) Mallat, 8) Rajalabanda in Manvi Taluk, 9) Mustoor, 10) Alkod, 11) Kothadoddi in Devdurga Taluk and (12) Gunda in Sindanur Taluk of Raichur District.
categoryWORKS
categoryTextWorks
ecv417291134.46
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount480000000.0
groupOverheadTotal0.0
fileNumberKKRDB-1
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17218879410000NoneNoneBuildingsSAGAMAKUNTA IN RAICHUR TALUK OF RAICHUR DISTRICT. (CIVIL WORKS)27665191.48
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3612502131324NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.100 Sqm486.93486.9317.49FalseNoneNoneFalseNoneFalse8516.40570
3612503131324NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum117.71117.71768.64FalseNoneNoneFalseNoneFalse90476.61440
3612504131324NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum126.38126.381311.57FalseNoneNoneFalseNoneFalse165756.21660
3612505131324NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum449.76449.76230.53FalseNoneNoneFalseNoneFalse103683.17280
3612506131324NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum167.27167.27225.13FalseNoneNoneFalseNoneFalse37657.49510
3612507131324NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3612508131324NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum329.57329.57807.35FalseNoneNoneFalseNoneFalse266078.33950
3612509131324NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum587.29587.29728.89FalseNoneNoneFalseNoneFalse428069.80810
3612510131324NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7420.377420.37161.37FalseNoneNoneFalseNoneFalse1197425.10690
3612511131324NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3612512131324NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3612513131324NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.4155.14FalseNoneNoneFalseNoneFalse794755.42740
3612514131324NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3612515131324NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3612516131324NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Tonne110837.22110837.2250.82FalseNoneNoneFalseNoneFalse5632747.52040
3612517131324None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3612518131324NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3612519131324NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3612520131324NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1623.091623.091313.93FalseNoneNoneFalseNoneFalse2132626.64370
3612521131324NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3612522131324NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3612523131324NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3612524131324None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3612525131324None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3612526131324None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3612527131324None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3612528131324None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3612529131324None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3612530131324NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3612531131324None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3612532131324NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3612533131324NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3612534131324NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3612535131324NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3612536131324NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.m869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3612537131324NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3612538131324NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3612539131324NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3612540131324NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3612541131324NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3612542131324NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3612543131324None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3612544131324None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3612545131324NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3612546131324NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3612547131324NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3612548131324NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3612549131324NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3612550131324NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3612551131324NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3612552131324NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3612553131324NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3612554131324NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3612555131324NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3612556131324NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3612557131324NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3612558131324None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3612559131324NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3612560131324NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3612561131324None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3612562131324NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3612563131324None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72102.35FalseNoneNoneFalseNoneFalse1301658.6420
3612564131324None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3612565131324None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3612566131324None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3612567131324None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3612568131324None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3612569131324None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3612570131324None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3612571131324None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3612572131324None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3612573131324None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3612574131324None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3612575131324None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3612576131324None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3612577131324None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3612578131324None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3612579131324None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3612580131324None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3612581131324None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3612582131324None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3612583131324None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3612584131324None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3612585131324None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3612586131324None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3612587131324None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3612588131324NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum130.1130.172.0FalseNoneNoneFalseNoneFalse9367.20
3612589131324NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3612590131324NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum6095.886095.8824.0FalseNoneNoneFalseNoneFalse146301.120
3612591131324NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11107.6411107.6448.0FalseNoneNoneFalseNoneFalse533166.720
3612592131324NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3612593131324NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3612594131324NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3612595131324None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7702.867702.862.0FalseNoneNoneFalseNoneFalse15405.720
3612596131324None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9156.769156.7610.8FalseNoneNoneFalseNoneFalse98893.0080
3612597131324None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm459.67459.67320.0FalseNoneNoneFalseNoneFalse147094.40
3612598131324None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm220.54220.54320.0FalseNoneNoneFalseNoneFalse70572.80
3612599131324None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3612600131324None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3612601131324NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3612602131324None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3612603131324None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3612604131324NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3612605131324NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3612606131324None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3612607131324None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3612608131324None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3612609131324NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3612610131324NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3612611131324NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3612612131324NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3612613131324NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3612614131324NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3612615131324NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3612616131324NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3612617131324None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3612618131324NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3612619131324NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3612620131324NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3612621131324NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3612622131324NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3612623131324NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3612624131324None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3612625131324NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3612626131324NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3612627131324None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3612628131324None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3612629131324None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3612630131324None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
17218879410000NoneNoneBuildingsSAGMAKUNTA IN RAICHUR TALUK (WATER SUPPLY AND SANITARY WORKS)2711710.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3612631131325NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3612632131325NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3612633131325NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3612634131325NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3612635131325NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3612636131325NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3612637131325NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3612638131325NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3612639131325NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3612640131325NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3612641131325NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3612642131325NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3612643131325NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3612644131325NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3612645131325NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3612646131325NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3612647131325NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3612648131325NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3612649131325NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3612650131325NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3612651131325NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3612652131325NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3612653131325NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3612654131325NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3612655131325NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3612656131325NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3612657131325NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3612658131325NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3612659131325NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3612660131325NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3612661131325NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3612662131325Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3612663131325NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3612664131325NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Ltr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3612665131325NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3612666131325NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3612667131325NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3612668131325NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3612669131325NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3612670131325NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3612671131325NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3612672131325NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3612673131325NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3612674131325NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3612675131325NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3612676131325NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3612677131325NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3612678131325None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3612679131325None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3612680131325None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3612681131325None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3612682131325None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3612683131325NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3612684131325None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3612685131325NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3612686131325NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3612687131325NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3612688131325NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3612689131325NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3612690131325NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3612691131325NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3612692131325NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3612693131325NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3612694131325NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3612695131325None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3612696131325None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3612697131325NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3612698131325None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3612699131325None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3612700131325None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
17218879410000NoneNoneBuildingsSAGAMAKUNTA IN RAICHUR TALUK (ELECTRICAL WORKS)4364380.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3612701131326NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3612702131326NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Pack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3612703131326NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3612704131326NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3612705131326NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3612706131326NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3612707131326NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3612708131326NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3612709131326NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3612710131326NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3612711131326NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3612712131326NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3612713131326NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3612714131326NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3612715131326NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3612716131326NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3612717131326NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3612718131326NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3612719131326NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3612720131326NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3612721131326NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3612722131326NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3612723131326NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3612724131326NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3612725131326NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3612726131326NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3612727131326NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3612728131326NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3612729131326NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3612730131326NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3612731131326NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3612732131326NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3612733131326NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3612734131326NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3612735131326NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3612736131326NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3612737131326NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3612738131326NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3612739131326NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3612740131326NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3612741131326None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3612742131326None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3612743131326None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3612744131326None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3612745131326None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3612746131326NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3612747131326NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3612748131326NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3612749131326NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3612750131326NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3612751131326NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3612752131326NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3612753131326NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3612754131326NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3612755131326NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3612756131326NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3612757131326NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3612758131326NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3612759131326NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3612760131326NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3612761131326NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3612762131326None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3612763131326None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3612764131326None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3612765131326None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3612766131326None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3612767131326None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3612768131326None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3612769131326None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3612770131326None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3612771131326None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3612772131326None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3612773131326None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3612774131326None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3612775131326None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3612776131326None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3612777131326None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3612778131326None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3612779131326None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3612780131326None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3612781131326None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3612782131326None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3612783131326None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3612784131326None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3612785131326None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3612786131326None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3612787131326Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3612788131326None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3612789131326None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3612790131326None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3612791131326None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3612792131326None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3612793131326None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3612794131326NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3612795131326NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3612796131326NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3612797131326NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3612798131326NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3612799131326NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3612800131326NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3612801131326NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3612802131326NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3612803131326NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3612804131326NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3612805131326NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3612806131326None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3612807131326None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3612808131326None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3612809131326None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3612810131326None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3612811131326None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3612812131326None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3612813131326None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3612814131326None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3612815131326None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3612816131326None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3612817131326None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3612818131326None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3612819131326None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3612820131326None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3612821131326None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3612822131326None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3612823131326None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3612824131326None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.MT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3612825131326None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3612826131326None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3612827131326None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3612828131326None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3612829131326None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3612830131326None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3612831131326None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3612832131326None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3612833131326None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3612834131326None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3612835131326None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3612836131326None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3612837131326None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3612838131326None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3612839131326NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3612840131326NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3612841131326None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3612842131326None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3612843131326None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3612844131326Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3612845131326Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3612846131326Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3612847131326Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3612848131326None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3612849131326Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3612850131326None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3612851131326None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218879410000NoneNoneBuildingsRAJALABANDA IN RAICHUR TALUK (CIVIL WORKS)34741282.93
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3612852131327NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.100 Sqm486.93486.9317.49FalseNoneNoneFalseNoneFalse8516.40570
3612853131327NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum117.71117.71768.64FalseNoneNoneFalseNoneFalse90476.61440
3612854131327NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum126.38126.381311.57FalseNoneNoneFalseNoneFalse165756.21660
3612855131327NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum449.76449.76230.53FalseNoneNoneFalseNoneFalse103683.17280
3612856131327NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum167.27167.27225.13FalseNoneNoneFalseNoneFalse37657.49510
3612857131327NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3612858131327NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum329.57329.57807.35FalseNoneNoneFalseNoneFalse266078.33950
3612859131327NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum587.29587.29728.89FalseNoneNoneFalseNoneFalse428069.80810
3612860131327NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7420.377420.37161.37FalseNoneNoneFalseNoneFalse1197425.10690
3612861131327NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3612862131327NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3612863131327NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.4155.14FalseNoneNoneFalseNoneFalse794755.42740
3612864131327NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3612865131327NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3612866131327NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Tonne110837.22110837.2250.82FalseNoneNoneFalseNoneFalse5632747.52040
3612867131327None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3612868131327NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3612869131327NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3612870131327NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1623.091623.091313.93FalseNoneNoneFalseNoneFalse2132626.64370
3612871131327NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3612872131327NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3612873131327NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3612874131327None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3612875131327None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3612876131327None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3612877131327None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3612878131327None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3612879131327None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3612880131327NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3612881131327None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3612882131327NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3612883131327NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3612884131327NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3612885131327NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3612886131327NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.m869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3612887131327NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3612888131327NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3612889131327NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3612890131327NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3612891131327NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3612892131327NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3612893131327None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3612894131327None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3612895131327NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3612896131327NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3612897131327NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3612898131327NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3612899131327NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3612900131327NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3612901131327NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3612902131327NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3612903131327NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3612904131327NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3612905131327NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3612906131327NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3612907131327NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3612908131327None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3612909131327NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3612910131327NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3612911131327None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3612912131327NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3612913131327None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72102.35FalseNoneNoneFalseNoneFalse1301658.6420
3612914131327None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3612915131327None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3612916131327None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3612917131327None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3612918131327None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3612919131327None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3612920131327None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3612921131327None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3612922131327None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3612923131327None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3612924131327None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3612925131327None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3612926131327None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3612927131327None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3612928131327None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3612929131327None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3612930131327None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3612931131327None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3612932131327None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3612933131327None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3612934131327None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3612935131327None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3612936131327None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3612937131327None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3612938131327NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum130.1130.172.0FalseNoneNoneFalseNoneFalse9367.20
3612939131327NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3612940131327NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum6095.886095.8824.0FalseNoneNoneFalseNoneFalse146301.120
3612941131327NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11107.6411107.6448.0FalseNoneNoneFalseNoneFalse533166.720
3612942131327NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3612943131327NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3612944131327NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3612945131327None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7702.867702.862.0FalseNoneNoneFalseNoneFalse15405.720
3612946131327None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9156.769156.7610.8FalseNoneNoneFalseNoneFalse98893.0080
3612947131327None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm459.67459.67320.0FalseNoneNoneFalseNoneFalse147094.40
3612948131327None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm220.54220.54320.0FalseNoneNoneFalseNoneFalse70572.80
3612949131327None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3612950131327None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3612951131327NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3612952131327None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3612953131327None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3612954131327NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3612955131327NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3612956131327None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3612957131327None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3612958131327None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3612959131327NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3612960131327NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3612961131327NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3612962131327NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3612963131327NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3612964131327NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3612965131327NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3612966131327NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3612967131327None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3612968131327NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3612969131327NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3612970131327NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3612971131327NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3612972131327NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3612973131327NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3612974131327None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3612975131327NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3612976131327NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3612977131327None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3612978131327None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3612979131327None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3612980131327None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
3612981131327NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3612982131327NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3612983131327NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3612984131327NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3612985131327NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3612986131327NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3612987131327NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3612988131327NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3612989131327NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3612990131327NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3612991131327NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3612992131327NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3612993131327NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3612994131327NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3612995131327NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3612996131327NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3612997131327NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3612998131327NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3612999131327NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3613000131327NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3613001131327NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3613002131327NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3613003131327NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3613004131327NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3613005131327NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3613006131327NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3613007131327NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3613008131327NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3613009131327NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3613010131327NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3613011131327NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3613012131327Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3613013131327NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3613014131327NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Ltr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3613015131327NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3613016131327NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3613017131327NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3613018131327NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3613019131327NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3613020131327NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3613021131327NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3613022131327NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3613023131327NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3613024131327NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3613025131327NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3613026131327NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3613027131327NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3613028131327None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3613029131327None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3613030131327None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3613031131327None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3613032131327None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3613033131327NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3613034131327None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3613035131327NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3613036131327NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3613037131327NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3613038131327NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3613039131327NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3613040131327NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3613041131327NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3613042131327NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3613043131327NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3613044131327NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3613045131327None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3613046131327None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3613047131327NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3613048131327None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3613049131327None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3613050131327None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
3613051131327NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3613052131327NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Pack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3613053131327NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3613054131327NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3613055131327NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3613056131327NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3613057131327NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3613058131327NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3613059131327NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3613060131327NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3613061131327NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3613062131327NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3613063131327NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3613064131327NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3613065131327NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3613066131327NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3613067131327NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3613068131327NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3613069131327NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3613070131327NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3613071131327NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3613072131327NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3613073131327NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3613074131327NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3613075131327NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3613076131327NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3613077131327NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3613078131327NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3613079131327NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3613080131327NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3613081131327NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3613082131327NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3613083131327NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3613084131327NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3613085131327NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3613086131327NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3613087131327NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3613088131327NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3613089131327NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3613090131327NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3613091131327None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3613092131327None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3613093131327None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3613094131327None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3613095131327None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3613096131327NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3613097131327NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3613098131327NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3613099131327NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3613100131327NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3613101131327NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3613102131327NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3613103131327NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3613104131327NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3613105131327NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3613106131327NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3613107131327NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3613108131327NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3613109131327NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3613110131327NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3613111131327NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3613112131327None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3613113131327None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3613114131327None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3613115131327None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3613116131327None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3613117131327None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3613118131327None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3613119131327None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3613120131327None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3613121131327None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3613122131327None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3613123131327None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3613124131327None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3613125131327None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3613126131327None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3613127131327None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3613128131327None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3613129131327None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3613130131327None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3613131131327None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3613132131327None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3613133131327None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3613134131327None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3613135131327None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3613136131327None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3613137131327Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3613138131327None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3613139131327None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3613140131327None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3613141131327None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3613142131327None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3613143131327None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3613144131327NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3613145131327NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3613146131327NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3613147131327NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3613148131327NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3613149131327NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3613150131327NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3613151131327NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3613152131327NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3613153131327NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3613154131327NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3613155131327NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3613156131327None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3613157131327None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3613158131327None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3613159131327None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3613160131327None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3613161131327None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3613162131327None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3613163131327None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3613164131327None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3613165131327None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3613166131327None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3613167131327None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3613168131327None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3613169131327None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3613170131327None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3613171131327None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3613172131327None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3613173131327None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3613174131327None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.MT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3613175131327None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3613176131327None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3613177131327None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3613178131327None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3613179131327None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3613180131327None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3613181131327None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3613182131327None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3613183131327None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3613184131327None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3613185131327None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3613186131327None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3613187131327None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3613188131327None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3613189131327NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3613190131327NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3613191131327None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3613192131327None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3613193131327None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3613194131327Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3613195131327Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3613196131327Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3613197131327Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3613198131327None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3613199131327Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3613200131327None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3613201131327None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218879420000NoneNoneBuildingsALKOD IN DEODURG TALUK OF RAICHUR DISTRICT.34741282.93
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3613202131328NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.100 Sqm486.93486.9317.49FalseNoneNoneFalseNoneFalse8516.40570
3613203131328NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum117.71117.71768.64FalseNoneNoneFalseNoneFalse90476.61440
3613204131328NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum126.38126.381311.57FalseNoneNoneFalseNoneFalse165756.21660
3613205131328NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum449.76449.76230.53FalseNoneNoneFalseNoneFalse103683.17280
3613206131328NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum167.27167.27225.13FalseNoneNoneFalseNoneFalse37657.49510
3613207131328NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3613208131328NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum329.57329.57807.35FalseNoneNoneFalseNoneFalse266078.33950
3613209131328NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum587.29587.29728.89FalseNoneNoneFalseNoneFalse428069.80810
3613210131328NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7420.377420.37161.37FalseNoneNoneFalseNoneFalse1197425.10690
3613211131328NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3613212131328NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3613213131328NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.4155.14FalseNoneNoneFalseNoneFalse794755.42740
3613214131328NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3613215131328NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3613216131328NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Tonne110837.22110837.2250.82FalseNoneNoneFalseNoneFalse5632747.52040
3613217131328None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3613218131328NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3613219131328NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3613220131328NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1623.091623.091313.93FalseNoneNoneFalseNoneFalse2132626.64370
3613221131328NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3613222131328NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3613223131328NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3613224131328None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3613225131328None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3613226131328None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3613227131328None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3613228131328None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3613229131328None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3613230131328NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3613231131328None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3613232131328NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3613233131328NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3613234131328NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3613235131328NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3613236131328NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.m869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3613237131328NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3613238131328NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3613239131328NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3613240131328NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3613241131328NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3613242131328NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3613243131328None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3613244131328None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3613245131328NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3613246131328NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3613247131328NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3613248131328NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3613249131328NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3613250131328NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3613251131328NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3613252131328NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3613253131328NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3613254131328NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3613255131328NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3613256131328NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3613257131328NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3613258131328None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3613259131328NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3613260131328NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3613261131328None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3613262131328NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3613263131328None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72102.35FalseNoneNoneFalseNoneFalse1301658.6420
3613264131328None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3613265131328None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3613266131328None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3613267131328None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3613268131328None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3613269131328None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3613270131328None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3613271131328None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3613272131328None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3613273131328None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3613274131328None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3613275131328None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3613276131328None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3613277131328None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3613278131328None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3613279131328None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3613280131328None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3613281131328None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3613282131328None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3613283131328None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3613284131328None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3613285131328None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3613286131328None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3613287131328None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3613288131328NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum130.1130.172.0FalseNoneNoneFalseNoneFalse9367.20
3613289131328NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3613290131328NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum6095.886095.8824.0FalseNoneNoneFalseNoneFalse146301.120
3613291131328NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11107.6411107.6448.0FalseNoneNoneFalseNoneFalse533166.720
3613292131328NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3613293131328NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3613294131328NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3613295131328None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7702.867702.862.0FalseNoneNoneFalseNoneFalse15405.720
3613296131328None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9156.769156.7610.8FalseNoneNoneFalseNoneFalse98893.0080
3613297131328None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm459.67459.67320.0FalseNoneNoneFalseNoneFalse147094.40
3613298131328None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm220.54220.54320.0FalseNoneNoneFalseNoneFalse70572.80
3613299131328None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3613300131328None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3613301131328NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3613302131328None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3613303131328None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3613304131328NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3613305131328NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3613306131328None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3613307131328None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3613308131328None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3613309131328NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3613310131328NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3613311131328NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3613312131328NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3613313131328NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3613314131328NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3613315131328NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3613316131328NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3613317131328None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3613318131328NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3613319131328NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3613320131328NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3613321131328NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3613322131328NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3613323131328NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3613324131328None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3613325131328NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3613326131328NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3613327131328None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3613328131328None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3613329131328None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3613330131328None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
3613331131328NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3613332131328NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3613333131328NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3613334131328NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3613335131328NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3613336131328NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3613337131328NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3613338131328NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3613339131328NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3613340131328NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3613341131328NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3613342131328NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3613343131328NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3613344131328NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3613345131328NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3613346131328NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3613347131328NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3613348131328NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3613349131328NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3613350131328NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3613351131328NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3613352131328NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3613353131328NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3613354131328NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3613355131328NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3613356131328NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3613357131328NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3613358131328NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3613359131328NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3613360131328NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3613361131328NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3613362131328Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3613363131328NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3613364131328NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Ltr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3613365131328NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3613366131328NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3613367131328NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3613368131328NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3613369131328NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3613370131328NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3613371131328NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3613372131328NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3613373131328NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3613374131328NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3613375131328NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3613376131328NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3613377131328NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3613378131328None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3613379131328None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3613380131328None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3613381131328None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3613382131328None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3613383131328NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3613384131328None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3613385131328NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3613386131328NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3613387131328NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3613388131328NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3613389131328NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3613390131328NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3613391131328NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3613392131328NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3613393131328NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3613394131328NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3613395131328None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3613396131328None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3613397131328NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3613398131328None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3613399131328None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3613400131328None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
3613401131328NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3613402131328NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Pack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3613403131328NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3613404131328NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3613405131328NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3613406131328NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3613407131328NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3613408131328NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3613409131328NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3613410131328NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3613411131328NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3613412131328NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3613413131328NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3613414131328NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3613415131328NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3613416131328NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3613417131328NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3613418131328NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3613419131328NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3613420131328NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3613421131328NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3613422131328NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3613423131328NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3613424131328NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3613425131328NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3613426131328NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3613427131328NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3613428131328NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3613429131328NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3613430131328NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3613431131328NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3613432131328NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3613433131328NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3613434131328NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3613435131328NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3613436131328NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3613437131328NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3613438131328NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3613439131328NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3613440131328NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3613441131328None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3613442131328None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3613443131328None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3613444131328None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3613445131328None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3613446131328NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3613447131328NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3613448131328NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3613449131328NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3613450131328NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3613451131328NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3613452131328NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3613453131328NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3613454131328NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3613455131328NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3613456131328NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3613457131328NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3613458131328NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3613459131328NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3613460131328NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3613461131328NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3613462131328None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3613463131328None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3613464131328None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3613465131328None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3613466131328None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3613467131328None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3613468131328None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3613469131328None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3613470131328None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3613471131328None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3613472131328None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3613473131328None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3613474131328None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3613475131328None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3613476131328None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3613477131328None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3613478131328None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3613479131328None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3613480131328None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3613481131328None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3613482131328None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3613483131328None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3613484131328None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3613485131328None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3613486131328None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3613487131328Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3613488131328None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3613489131328None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3613490131328None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3613491131328None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3613492131328None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3613493131328None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3613494131328NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3613495131328NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3613496131328NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3613497131328NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3613498131328NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3613499131328NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3613500131328NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3613501131328NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3613502131328NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3613503131328NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3613504131328NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3613505131328NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3613506131328None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3613507131328None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3613508131328None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3613509131328None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3613510131328None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3613511131328None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3613512131328None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3613513131328None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3613514131328None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3613515131328None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3613516131328None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3613517131328None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3613518131328None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3613519131328None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3613520131328None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3613521131328None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3613522131328None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3613523131328None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3613524131328None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.MT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3613525131328None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3613526131328None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3613527131328None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3613528131328None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3613529131328None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3613530131328None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3613531131328None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3613532131328None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3613533131328None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3613534131328None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3613535131328None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3613536131328None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3613537131328None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3613538131328None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3613539131328NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3613540131328NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3613541131328None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3613542131328None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3613543131328None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3613544131328Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3613545131328Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3613546131328Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3613547131328Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3613548131328None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3613549131328Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3613550131328None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3613551131328None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218879420000NoneNoneBuildingsKOTHADODDI IN DEODURG TALUK OF RAICHUR DISTRICT.34741282.93
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3613552131329NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.100 Sqm486.93486.9317.49FalseNoneNoneFalseNoneFalse8516.40570
3613553131329NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum117.71117.71768.64FalseNoneNoneFalseNoneFalse90476.61440
3613554131329NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum126.38126.381311.57FalseNoneNoneFalseNoneFalse165756.21660
3613555131329NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum449.76449.76230.53FalseNoneNoneFalseNoneFalse103683.17280
3613556131329NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum167.27167.27225.13FalseNoneNoneFalseNoneFalse37657.49510
3613557131329NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3613558131329NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum329.57329.57807.35FalseNoneNoneFalseNoneFalse266078.33950
3613559131329NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum587.29587.29728.89FalseNoneNoneFalseNoneFalse428069.80810
3613560131329NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7420.377420.37161.37FalseNoneNoneFalseNoneFalse1197425.10690
3613561131329NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3613562131329NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3613563131329NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.4155.14FalseNoneNoneFalseNoneFalse794755.42740
3613564131329NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3613565131329NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3613566131329NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Tonne110837.22110837.2250.82FalseNoneNoneFalseNoneFalse5632747.52040
3613567131329None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3613568131329NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3613569131329NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3613570131329NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1623.091623.091313.93FalseNoneNoneFalseNoneFalse2132626.64370
3613571131329NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3613572131329NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3613573131329NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3613574131329None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3613575131329None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3613576131329None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3613577131329None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3613578131329None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3613579131329None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3613580131329NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3613581131329None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3613582131329NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3613583131329NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3613584131329NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3613585131329NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3613586131329NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.m869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3613587131329NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3613588131329NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3613589131329NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3613590131329NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3613591131329NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3613592131329NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3613593131329None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3613594131329None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3613595131329NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3613596131329NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3613597131329NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3613598131329NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3613599131329NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3613600131329NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3613601131329NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3613602131329NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3613603131329NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3613604131329NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3613605131329NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3613606131329NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3613607131329NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3613608131329None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3613609131329NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3613610131329NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3613611131329None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3613612131329NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3613613131329None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72102.35FalseNoneNoneFalseNoneFalse1301658.6420
3613614131329None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3613615131329None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3613616131329None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3613617131329None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3613618131329None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3613619131329None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3613620131329None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3613621131329None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3613622131329None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3613623131329None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3613624131329None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3613625131329None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3613626131329None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3613627131329None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3613628131329None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3613629131329None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3613630131329None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3613631131329None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3613632131329None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3613633131329None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3613634131329None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3613635131329None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3613636131329None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3613637131329None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3613638131329NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum130.1130.172.0FalseNoneNoneFalseNoneFalse9367.20
3613639131329NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3613640131329NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum6095.886095.8824.0FalseNoneNoneFalseNoneFalse146301.120
3613641131329NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11107.6411107.6448.0FalseNoneNoneFalseNoneFalse533166.720
3613642131329NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3613643131329NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3613644131329NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3613645131329None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7702.867702.862.0FalseNoneNoneFalseNoneFalse15405.720
3613646131329None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9156.769156.7610.8FalseNoneNoneFalseNoneFalse98893.0080
3613647131329None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm459.67459.67320.0FalseNoneNoneFalseNoneFalse147094.40
3613648131329None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm220.54220.54320.0FalseNoneNoneFalseNoneFalse70572.80
3613649131329None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3613650131329None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3613651131329NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3613652131329None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3613653131329None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3613654131329NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3613655131329NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3613656131329None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3613657131329None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3613658131329None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3613659131329NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3613660131329NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3613661131329NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3613662131329NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3613663131329NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3613664131329NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3613665131329NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3613666131329NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3613667131329None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3613668131329NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3613669131329NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3613670131329NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3613671131329NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3613672131329NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3613673131329NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3613674131329None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3613675131329NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3613676131329NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3613677131329None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3613678131329None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3613679131329None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3613680131329None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
3613681131329NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3613682131329NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3613683131329NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3613684131329NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3613685131329NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3613686131329NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3613687131329NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3613688131329NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3613689131329NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3613690131329NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3613691131329NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3613692131329NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3613693131329NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3613694131329NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3613695131329NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3613696131329NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3613697131329NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3613698131329NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3613699131329NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3613700131329NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3613701131329NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3613702131329NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3613703131329NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3613704131329NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3613705131329NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3613706131329NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3613707131329NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3613708131329NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3613709131329NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3613710131329NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3613711131329NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3613712131329Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3613713131329NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3613714131329NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Ltr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3613715131329NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3613716131329NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3613717131329NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3613718131329NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3613719131329NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3613720131329NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3613721131329NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3613722131329NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3613723131329NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3613724131329NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3613725131329NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3613726131329NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3613727131329NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3613728131329None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3613729131329None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3613730131329None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3613731131329None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3613732131329None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3613733131329NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3613734131329None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3613735131329NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3613736131329NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3613737131329NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3613738131329NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3613739131329NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3613740131329NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3613741131329NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3613742131329NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3613743131329NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3613744131329NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3613745131329None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3613746131329None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3613747131329NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3613748131329None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3613749131329None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3613750131329None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
3613751131329NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3613752131329NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Pack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3613753131329NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3613754131329NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3613755131329NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3613756131329NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3613757131329NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3613758131329NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3613759131329NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3613760131329NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3613761131329NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3613762131329NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3613763131329NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3613764131329NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3613765131329NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3613766131329NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3613767131329NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3613768131329NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3613769131329NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3613770131329NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3613771131329NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3613772131329NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3613773131329NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3613774131329NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3613775131329NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3613776131329NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3613777131329NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3613778131329NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3613779131329NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3613780131329NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3613781131329NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3613782131329NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3613783131329NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3613784131329NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3613785131329NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3613786131329NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3613787131329NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3613788131329NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3613789131329NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3613790131329NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3613791131329None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3613792131329None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3613793131329None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3613794131329None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3613795131329None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3613796131329NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3613797131329NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3613798131329NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3613799131329NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3613800131329NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3613801131329NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3613802131329NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3613803131329NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3613804131329NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3613805131329NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3613806131329NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3613807131329NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3613808131329NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3613809131329NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3613810131329NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3613811131329NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3613812131329None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3613813131329None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3613814131329None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3613815131329None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3613816131329None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3613817131329None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3613818131329None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3613819131329None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3613820131329None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3613821131329None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3613822131329None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3613823131329None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3613824131329None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3613825131329None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3613826131329None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3613827131329None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3613828131329None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3613829131329None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3613830131329None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3613831131329None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3613832131329None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3613833131329None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3613834131329None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3613835131329None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3613836131329None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3613837131329Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3613838131329None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3613839131329None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3613840131329None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3613841131329None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3613842131329None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3613843131329None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3613844131329NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3613845131329NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3613846131329NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3613847131329NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3613848131329NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3613849131329NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3613850131329NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3613851131329NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3613852131329NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3613853131329NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3613854131329NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3613855131329NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3613856131329None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3613857131329None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3613858131329None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3613859131329None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3613860131329None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3613861131329None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3613862131329None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3613863131329None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3613864131329None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3613865131329None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3613866131329None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3613867131329None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3613868131329None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3613869131329None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3613870131329None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3613871131329None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3613872131329None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3613873131329None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3613874131329None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.MT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3613875131329None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3613876131329None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3613877131329None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3613878131329None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3613879131329None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3613880131329None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3613881131329None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3613882131329None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3613883131329None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3613884131329None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3613885131329None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3613886131329None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3613887131329None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3613888131329None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3613889131329NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3613890131329NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3613891131329None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3613892131329None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3613893131329None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3613894131329Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3613895131329Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3613896131329Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3613897131329Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3613898131329None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3613899131329Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3613900131329None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3613901131329None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218879420000NoneNoneBuildingsGUNDA IN SINDHANUR TALUK OF RAICHUR DISTRICT.34741282.93
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3613902131330NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.100 Sqm486.93486.9317.49FalseNoneNoneFalseNoneFalse8516.40570
3613903131330NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum117.71117.71768.64FalseNoneNoneFalseNoneFalse90476.61440
3613904131330NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum126.38126.381311.57FalseNoneNoneFalseNoneFalse165756.21660
3613905131330NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum449.76449.76230.53FalseNoneNoneFalseNoneFalse103683.17280
3613906131330NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum167.27167.27225.13FalseNoneNoneFalseNoneFalse37657.49510
3613907131330NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3613908131330NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum329.57329.57807.35FalseNoneNoneFalseNoneFalse266078.33950
3613909131330NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum587.29587.29728.89FalseNoneNoneFalseNoneFalse428069.80810
3613910131330NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7420.377420.37161.37FalseNoneNoneFalseNoneFalse1197425.10690
3613911131330NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3613912131330NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3613913131330NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.4155.14FalseNoneNoneFalseNoneFalse794755.42740
3613914131330NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3613915131330NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3613916131330NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Tonne110837.22110837.2250.82FalseNoneNoneFalseNoneFalse5632747.52040
3613917131330None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3613918131330NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3613919131330NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3613920131330NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1623.091623.091313.93FalseNoneNoneFalseNoneFalse2132626.64370
3613921131330NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3613922131330NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3613923131330NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3613924131330None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3613925131330None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3613926131330None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3613927131330None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3613928131330None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3613929131330None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3613930131330NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3613931131330None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3613932131330NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3613933131330NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3613934131330NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3613935131330NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3613936131330NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.m869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3613937131330NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3613938131330NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3613939131330NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3613940131330NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3613941131330NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3613942131330NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3613943131330None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3613944131330None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3613945131330NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3613946131330NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3613947131330NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3613948131330NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3613949131330NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3613950131330NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3613951131330NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3613952131330NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3613953131330NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3613954131330NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3613955131330NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3613956131330NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3613957131330NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3613958131330None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3613959131330NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3613960131330NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3613961131330None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3613962131330NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3613963131330None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72102.35FalseNoneNoneFalseNoneFalse1301658.6420
3613964131330None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3613965131330None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3613966131330None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3613967131330None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3613968131330None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3613969131330None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3613970131330None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3613971131330None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3613972131330None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3613973131330None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3613974131330None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3613975131330None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3613976131330None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3613977131330None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3613978131330None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3613979131330None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3613980131330None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3613981131330None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3613982131330None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3613983131330None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3613984131330None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3613985131330None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3613986131330None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3613987131330None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3613988131330NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum130.1130.172.0FalseNoneNoneFalseNoneFalse9367.20
3613989131330NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3613990131330NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum6095.886095.8824.0FalseNoneNoneFalseNoneFalse146301.120
3613991131330NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11107.6411107.6448.0FalseNoneNoneFalseNoneFalse533166.720
3613992131330NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3613993131330NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3613994131330NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3613995131330None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7702.867702.862.0FalseNoneNoneFalseNoneFalse15405.720
3613996131330None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9156.769156.7610.8FalseNoneNoneFalseNoneFalse98893.0080
3613997131330None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm459.67459.67320.0FalseNoneNoneFalseNoneFalse147094.40
3613998131330None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm220.54220.54320.0FalseNoneNoneFalseNoneFalse70572.80
3613999131330None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3614000131330None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3614001131330NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3614002131330None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3614003131330None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3614004131330NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3614005131330NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3614006131330None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3614007131330None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3614008131330None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3614009131330NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3614010131330NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3614011131330NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3614012131330NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3614013131330NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3614014131330NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3614015131330NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3614016131330NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3614017131330None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3614018131330NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3614019131330NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3614020131330NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3614021131330NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3614022131330NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3614023131330NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3614024131330None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3614025131330NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3614026131330NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3614027131330None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3614028131330None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3614029131330None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3614030131330None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
3614031131330NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3614032131330NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3614033131330NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3614034131330NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3614035131330NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3614036131330NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3614037131330NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3614038131330NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3614039131330NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3614040131330NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3614041131330NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3614042131330NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3614043131330NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3614044131330NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3614045131330NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3614046131330NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3614047131330NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3614048131330NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3614049131330NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3614050131330NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3614051131330NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3614052131330NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3614053131330NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3614054131330NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3614055131330NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3614056131330NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3614057131330NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3614058131330NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3614059131330NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3614060131330NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3614061131330NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3614062131330Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3614063131330NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3614064131330NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Ltr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3614065131330NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3614066131330NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3614067131330NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3614068131330NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3614069131330NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3614070131330NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3614071131330NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3614072131330NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3614073131330NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3614074131330NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3614075131330NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3614076131330NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3614077131330NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3614078131330None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3614079131330None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3614080131330None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3614081131330None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3614082131330None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3614083131330NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3614084131330None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3614085131330NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3614086131330NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3614087131330NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3614088131330NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3614089131330NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3614090131330NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3614091131330NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3614092131330NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3614093131330NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3614094131330NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3614095131330None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3614096131330None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3614097131330NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3614098131330None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3614099131330None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3614100131330None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
3614101131330NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3614102131330NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Pack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3614103131330NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3614104131330NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3614105131330NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3614106131330NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3614107131330NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3614108131330NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3614109131330NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3614110131330NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3614111131330NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3614112131330NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3614113131330NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3614114131330NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3614115131330NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3614116131330NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3614117131330NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3614118131330NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3614119131330NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3614120131330NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3614121131330NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3614122131330NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3614123131330NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3614124131330NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3614125131330NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3614126131330NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3614127131330NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3614128131330NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3614129131330NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3614130131330NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3614131131330NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3614132131330NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3614133131330NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3614134131330NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3614135131330NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3614136131330NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3614137131330NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3614138131330NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3614139131330NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3614140131330NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3614141131330None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3614142131330None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3614143131330None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3614144131330None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3614145131330None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3614146131330NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3614147131330NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3614148131330NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3614149131330NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3614150131330NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3614151131330NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3614152131330NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3614153131330NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3614154131330NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3614155131330NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3614156131330NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3614157131330NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3614158131330NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3614159131330NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3614160131330NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3614161131330NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3614162131330None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3614163131330None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3614164131330None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3614165131330None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3614166131330None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3614167131330None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3614168131330None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3614169131330None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3614170131330None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3614171131330None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3614172131330None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3614173131330None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3614174131330None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3614175131330None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3614176131330None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3614177131330None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3614178131330None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3614179131330None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3614180131330None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3614181131330None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3614182131330None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3614183131330None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3614184131330None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3614185131330None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3614186131330None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3614187131330Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3614188131330None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3614189131330None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3614190131330None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3614191131330None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3614192131330None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3614193131330None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3614194131330NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3614195131330NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3614196131330NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3614197131330NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3614198131330NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3614199131330NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3614200131330NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3614201131330NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3614202131330NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3614203131330NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3614204131330NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3614205131330NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3614206131330None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3614207131330None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3614208131330None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3614209131330None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3614210131330None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3614211131330None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3614212131330None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3614213131330None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3614214131330None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3614215131330None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3614216131330None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3614217131330None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3614218131330None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3614219131330None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3614220131330None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3614221131330None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3614222131330None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3614223131330None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3614224131330None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.MT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3614225131330None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3614226131330None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3614227131330None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3614228131330None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3614229131330None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3614230131330None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3614231131330None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3614232131330None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3614233131330None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3614234131330None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3614235131330None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3614236131330None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3614237131330None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3614238131330None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3614239131330NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3614240131330NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3614241131330None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3614242131330None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3614243131330None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3614244131330Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3614245131330Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3614246131330Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3614247131330Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3614248131330None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3614249131330Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3614250131330None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3614251131330None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218879420000NoneNoneBuildingsNAGLAPUR IN LINGASUGUR TALUK OF RAICHUR DISTRICT.34741282.93
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3614252131331NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.100 Sqm486.93486.9317.49FalseNoneNoneFalseNoneFalse8516.40570
3614253131331NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum117.71117.71768.64FalseNoneNoneFalseNoneFalse90476.61440
3614254131331NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum126.38126.381311.57FalseNoneNoneFalseNoneFalse165756.21660
3614255131331NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum449.76449.76230.53FalseNoneNoneFalseNoneFalse103683.17280
3614256131331NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum167.27167.27225.13FalseNoneNoneFalseNoneFalse37657.49510
3614257131331NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3614258131331NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum329.57329.57807.35FalseNoneNoneFalseNoneFalse266078.33950
3614259131331NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum587.29587.29728.89FalseNoneNoneFalseNoneFalse428069.80810
3614260131331NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7420.377420.37161.37FalseNoneNoneFalseNoneFalse1197425.10690
3614261131331NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3614262131331NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3614263131331NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.4155.14FalseNoneNoneFalseNoneFalse794755.42740
3614264131331NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3614265131331NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3614266131331NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Tonne110837.22110837.2250.82FalseNoneNoneFalseNoneFalse5632747.52040
3614267131331None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3614268131331NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3614269131331NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3614270131331NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1623.091623.091313.93FalseNoneNoneFalseNoneFalse2132626.64370
3614271131331NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3614272131331NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3614273131331NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3614274131331None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3614275131331None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3614276131331None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3614277131331None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3614278131331None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3614279131331None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3614280131331NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3614281131331None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3614282131331NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3614283131331NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3614284131331NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3614285131331NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3614286131331NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.m869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3614287131331NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3614288131331NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3614289131331NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3614290131331NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3614291131331NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3614292131331NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3614293131331None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3614294131331None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3614295131331NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3614296131331NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3614297131331NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3614298131331NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3614299131331NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3614300131331NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3614301131331NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3614302131331NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3614303131331NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3614304131331NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3614305131331NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3614306131331NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3614307131331NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3614308131331None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3614309131331NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3614310131331NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3614311131331None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3614312131331NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3614313131331None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72102.35FalseNoneNoneFalseNoneFalse1301658.6420
3614314131331None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3614315131331None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3614316131331None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3614317131331None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3614318131331None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3614319131331None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3614320131331None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3614321131331None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3614322131331None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3614323131331None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3614324131331None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3614325131331None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3614326131331None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3614327131331None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3614328131331None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3614329131331None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3614330131331None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3614331131331None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3614332131331None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3614333131331None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3614334131331None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3614335131331None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3614336131331None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3614337131331None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3614338131331NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum130.1130.172.0FalseNoneNoneFalseNoneFalse9367.20
3614339131331NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3614340131331NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum6095.886095.8824.0FalseNoneNoneFalseNoneFalse146301.120
3614341131331NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11107.6411107.6448.0FalseNoneNoneFalseNoneFalse533166.720
3614342131331NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3614343131331NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3614344131331NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3614345131331None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7702.867702.862.0FalseNoneNoneFalseNoneFalse15405.720
3614346131331None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9156.769156.7610.8FalseNoneNoneFalseNoneFalse98893.0080
3614347131331None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm459.67459.67320.0FalseNoneNoneFalseNoneFalse147094.40
3614348131331None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm220.54220.54320.0FalseNoneNoneFalseNoneFalse70572.80
3614349131331None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3614350131331None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3614351131331NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3614352131331None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3614353131331None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3614354131331NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3614355131331NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3614356131331None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3614357131331None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3614358131331None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3614359131331NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3614360131331NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3614361131331NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3614362131331NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3614363131331NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3614364131331NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3614365131331NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3614366131331NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3614367131331None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3614368131331NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3614369131331NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3614370131331NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3614371131331NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3614372131331NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3614373131331NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3614374131331None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3614375131331NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3614376131331NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3614377131331None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3614378131331None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3614379131331None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3614380131331None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
3614381131331NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3614382131331NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3614383131331NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3614384131331NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3614385131331NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3614386131331NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3614387131331NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3614388131331NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3614389131331NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3614390131331NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3614391131331NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3614392131331NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3614393131331NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3614394131331NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3614395131331NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3614396131331NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3614397131331NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3614398131331NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3614399131331NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3614400131331NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3614401131331NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3614402131331NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3614403131331NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3614404131331NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3614405131331NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3614406131331NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3614407131331NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3614408131331NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3614409131331NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3614410131331NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3614411131331NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3614412131331Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3614413131331NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3614414131331NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Ltr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3614415131331NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3614416131331NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3614417131331NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3614418131331NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3614419131331NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3614420131331NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3614421131331NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3614422131331NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3614423131331NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3614424131331NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3614425131331NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3614426131331NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3614427131331NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3614428131331None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3614429131331None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3614430131331None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3614431131331None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3614432131331None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3614433131331NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3614434131331None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3614435131331NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3614436131331NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3614437131331NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3614438131331NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3614439131331NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3614440131331NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3614441131331NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3614442131331NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3614443131331NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3614444131331NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3614445131331None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3614446131331None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3614447131331NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3614448131331None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3614449131331None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3614450131331None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
3614451131331NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3614452131331NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Pack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3614453131331NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3614454131331NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3614455131331NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3614456131331NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3614457131331NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3614458131331NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3614459131331NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3614460131331NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3614461131331NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3614462131331NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3614463131331NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3614464131331NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3614465131331NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3614466131331NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3614467131331NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3614468131331NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3614469131331NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3614470131331NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3614471131331NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3614472131331NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3614473131331NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3614474131331NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3614475131331NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3614476131331NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3614477131331NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3614478131331NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3614479131331NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3614480131331NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3614481131331NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3614482131331NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3614483131331NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3614484131331NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3614485131331NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3614486131331NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3614487131331NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3614488131331NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3614489131331NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3614490131331NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3614491131331None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3614492131331None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3614493131331None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3614494131331None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3614495131331None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3614496131331NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3614497131331NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3614498131331NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3614499131331NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3614500131331NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3614501131331NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3614502131331NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3614503131331NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3614504131331NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3614505131331NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3614506131331NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3614507131331NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3614508131331NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3614509131331NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3614510131331NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3614511131331NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3614512131331None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3614513131331None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3614514131331None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3614515131331None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3614516131331None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3614517131331None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3614518131331None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3614519131331None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3614520131331None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3614521131331None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3614522131331None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3614523131331None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3614524131331None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3614525131331None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3614526131331None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3614527131331None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3614528131331None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3614529131331None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3614530131331None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3614531131331None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3614532131331None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3614533131331None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3614534131331None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3614535131331None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3614536131331None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3614537131331Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3614538131331None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3614539131331None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3614540131331None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3614541131331None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3614542131331None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3614543131331None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3614544131331NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3614545131331NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3614546131331NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3614547131331NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3614548131331NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3614549131331NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3614550131331NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3614551131331NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3614552131331NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3614553131331NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3614554131331NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3614555131331NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3614556131331None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3614557131331None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3614558131331None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3614559131331None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3614560131331None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3614561131331None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3614562131331None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3614563131331None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3614564131331None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3614565131331None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3614566131331None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3614567131331None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3614568131331None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3614569131331None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3614570131331None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3614571131331None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3614572131331None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3614573131331None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3614574131331None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.MT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3614575131331None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3614576131331None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3614577131331None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3614578131331None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3614579131331None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3614580131331None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3614581131331None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3614582131331None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3614583131331None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3614584131331None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3614585131331None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3614586131331None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3614587131331None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3614588131331None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3614589131331NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3614590131331NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3614591131331None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3614592131331None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3614593131331None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3614594131331Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3614595131331Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3614596131331Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3614597131331Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3614598131331None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3614599131331Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3614600131331None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3614601131331None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218879420000NoneNoneBuildingsYEDLAPUR IN RAICHUR TALUK OF RAICHUR DISTIRCT.27736381.66
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3614602131332NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.100 Sqm486.93486.9317.09FalseNoneNoneFalseNoneFalse8321.63370
3614603131332NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum117.71117.71540.95FalseNoneNoneFalseNoneFalse63675.22450
3614604131332NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum126.38126.381430.43FalseNoneNoneFalseNoneFalse180777.74340
3614605131332NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum449.76449.76254.05FalseNoneNoneFalseNoneFalse114261.5280
3614606131332NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum167.27167.27218.94FalseNoneNoneFalseNoneFalse36622.09380
3614607131332NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3614608131332NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum329.57329.57901.41FalseNoneNoneFalseNoneFalse297077.69370
3614609131332NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum587.29587.29747.04FalseNoneNoneFalseNoneFalse438729.12160
3614610131332NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7420.377420.37155.33FalseNoneNoneFalseNoneFalse1152606.07210
3614611131332NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3614612131332NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3614613131332NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.4157.58FalseNoneNoneFalseNoneFalse829924.14780
3614614131332NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3614615131332NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3614616131332NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Tonne110837.22110837.2250.59FalseNoneNoneFalseNoneFalse5607254.95980
3614617131332None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3614618131332NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3614619131332NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3614620131332NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1623.091623.091253.93FalseNoneNoneFalseNoneFalse2035241.24370
3614621131332NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3614622131332NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3614623131332NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3614624131332None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3614625131332None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3614626131332None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3614627131332None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3614628131332None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3614629131332None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3614630131332NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3614631131332None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3614632131332NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3614633131332NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3614634131332NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3614635131332NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3614636131332NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.m869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3614637131332NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3614638131332NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3614639131332NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3614640131332NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3614641131332NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3614642131332NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3614643131332None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3614644131332None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3614645131332NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3614646131332NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3614647131332NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3614648131332NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3614649131332NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3614650131332NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3614651131332NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3614652131332NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3614653131332NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3614654131332NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3614655131332NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3614656131332NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3614657131332NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3614658131332None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3614659131332NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3614660131332NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3614661131332None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3614662131332NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3614663131332None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.7294.35FalseNoneNoneFalseNoneFalse1199916.8820
3614664131332None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3614665131332None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3614666131332None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3614667131332None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3614668131332None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3614669131332None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3614670131332None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3614671131332None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3614672131332None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3614673131332None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3614674131332None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3614675131332None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3614676131332None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3614677131332None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3614678131332None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3614679131332None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3614680131332None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3614681131332None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3614682131332None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3614683131332None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3614684131332None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3614685131332None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3614686131332None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3614687131332None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3614688131332NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum130.1130.160.0FalseNoneNoneFalseNoneFalse7806.00
3614689131332NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum2922.82922.830.0FalseNoneNoneFalseNoneFalse87684.00
3614690131332NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum6095.886095.8820.0FalseNoneNoneFalseNoneFalse121917.60
3614691131332NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11107.6411107.6440.0FalseNoneNoneFalseNoneFalse444305.60
3614692131332NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3614693131332NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3614694131332NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each296.12296.12100.0FalseNoneNoneFalseNoneFalse29612.00
3614695131332None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7702.867702.861.2FalseNoneNoneFalseNoneFalse9243.4320
3614696131332None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9156.769156.766.48FalseNoneNoneFalseNoneFalse59335.80480
3614697131332None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm459.67459.67192.0FalseNoneNoneFalseNoneFalse88256.640
3614698131332None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm220.54220.54192.0FalseNoneNoneFalseNoneFalse42343.680
3614699131332None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3614700131332None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3614701131332NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3614702131332None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3614703131332None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3614704131332NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3614705131332NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3614706131332None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3614707131332None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3614708131332None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3614709131332NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3614710131332NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3614711131332NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3614712131332NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3614713131332NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3614714131332NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3614715131332NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3614716131332NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3614717131332None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3614718131332NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3614719131332NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3614720131332NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3614721131332NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3614722131332NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3614723131332NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3614724131332None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3614725131332NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3614726131332NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3614727131332None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3614728131332None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3614729131332None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3614730131332None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
3614731131332None1.23Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum3323.03323.0164.36FalseNoneNoneFalseNoneFalse546168.280
17218879420000NoneNoneBuildingsYEDLAPUR IN RAICHUR TALUK OF RAICHUR DISTIRCT. (WATER SUPPLY WORKS)2711710.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3614732131333NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3614733131333NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3614734131333NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3614735131333NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3614736131333NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3614737131333NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3614738131333NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3614739131333NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3614740131333NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3614741131333NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3614742131333NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3614743131333NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3614744131333NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3614745131333NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3614746131333NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3614747131333NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3614748131333NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3614749131333NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3614750131333NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3614751131333NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3614752131333NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3614753131333NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3614754131333NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3614755131333NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3614756131333NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3614757131333NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3614758131333NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3614759131333NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3614760131333NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3614761131333NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3614762131333NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3614763131333Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3614764131333NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3614765131333NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Ltr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3614766131333NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3614767131333NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3614768131333NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3614769131333NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3614770131333NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3614771131333NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3614772131333NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3614773131333NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3614774131333NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3614775131333NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3614776131333NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3614777131333NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3614778131333NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3614779131333None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3614780131333None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3614781131333None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3614782131333None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3614783131333None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3614784131333NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3614785131333None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3614786131333NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3614787131333NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3614788131333NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3614789131333NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3614790131333NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3614791131333NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3614792131333NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3614793131333NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3614794131333NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3614795131333NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3614796131333None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3614797131333None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3614798131333NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3614799131333None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3614800131333None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3614801131333None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
17218879420000NoneNoneBuildingsYEDLAPUR IN RAICHUR TALUK OF RAICHUR DISTIRCT (ELECTRICAL WORKS)4364380.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3614802131334NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3614803131334NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Pack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3614804131334NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3614805131334NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3614806131334NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3614807131334NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3614808131334NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3614809131334NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3614810131334NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3614811131334NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3614812131334NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3614813131334NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3614814131334NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3614815131334NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3614816131334NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3614817131334NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3614818131334NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3614819131334NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3614820131334NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3614821131334NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3614822131334NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3614823131334NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3614824131334NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3614825131334NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3614826131334NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3614827131334NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3614828131334NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3614829131334NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3614830131334NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3614831131334NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3614832131334NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3614833131334NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3614834131334NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3614835131334NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3614836131334NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3614837131334NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3614838131334NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3614839131334NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3614840131334NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3614841131334NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3614842131334None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3614843131334None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3614844131334None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3614845131334None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3614846131334None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3614847131334NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3614848131334NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3614849131334NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3614850131334NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3614851131334NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3614852131334NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3614853131334NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3614854131334NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3614855131334NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3614856131334NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3614857131334NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3614858131334NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3614859131334NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3614860131334NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3614861131334NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3614862131334NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3614863131334None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3614864131334None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3614865131334None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3614866131334None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3614867131334None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3614868131334None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3614869131334None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3614870131334None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3614871131334None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3614872131334None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3614873131334None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3614874131334None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3614875131334None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3614876131334None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3614877131334None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3614878131334None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3614879131334None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3614880131334None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3614881131334None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3614882131334None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3614883131334None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3614884131334None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3614885131334None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3614886131334None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3614887131334None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3614888131334Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3614889131334None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3614890131334None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3614891131334None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3614892131334None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3614893131334None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3614894131334None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3614895131334NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3614896131334NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3614897131334NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3614898131334NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3614899131334NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3614900131334NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3614901131334NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3614902131334NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3614903131334NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3614904131334NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3614905131334NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3614906131334NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3614907131334None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3614908131334None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3614909131334None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3614910131334None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3614911131334None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3614912131334None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3614913131334None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3614914131334None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3614915131334None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3614916131334None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3614917131334None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3614918131334None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3614919131334None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3614920131334None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3614921131334None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3614922131334None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3614923131334None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3614924131334None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3614925131334None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.MT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3614926131334None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3614927131334None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3614928131334None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3614929131334None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3614930131334None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3614931131334None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3614932131334None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3614933131334None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3614934131334None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3614935131334None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3614936131334None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3614937131334None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3614938131334None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3614939131334None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3614940131334NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3614941131334NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3614942131334None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3614943131334None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3614944131334None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3614945131334Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3614946131334Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3614947131334Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3614948131334Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3614949131334None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3614950131334Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3614951131334None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3614952131334None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218879420000NoneNoneBuildingsMALLAT IN MANVI TALUK OF RAICHUR DISTRICT34812473.11
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3614953131335NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.100 Sqm486.93486.9317.09FalseNoneNoneFalseNoneFalse8321.63370
3614954131335NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum117.71117.71540.95FalseNoneNoneFalseNoneFalse63675.22450
3614955131335NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum126.38126.381430.43FalseNoneNoneFalseNoneFalse180777.74340
3614956131335NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum449.76449.76254.05FalseNoneNoneFalseNoneFalse114261.5280
3614957131335NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum167.27167.27218.94FalseNoneNoneFalseNoneFalse36622.09380
3614958131335NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3614959131335NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum329.57329.57901.41FalseNoneNoneFalseNoneFalse297077.69370
3614960131335NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum587.29587.29747.04FalseNoneNoneFalseNoneFalse438729.12160
3614961131335NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7420.377420.37155.33FalseNoneNoneFalseNoneFalse1152606.07210
3614962131335NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3614963131335NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3614964131335NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.4157.58FalseNoneNoneFalseNoneFalse829924.14780
3614965131335NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3614966131335NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3614967131335NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Tonne110837.22110837.2250.59FalseNoneNoneFalseNoneFalse5607254.95980
3614968131335None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3614969131335NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3614970131335NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3614971131335NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1623.091623.091253.93FalseNoneNoneFalseNoneFalse2035241.24370
3614972131335NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3614973131335NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3614974131335NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3614975131335None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3614976131335None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3614977131335None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3614978131335None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3614979131335None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3614980131335None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3614981131335NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3614982131335None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3614983131335NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3614984131335NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3614985131335NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3614986131335NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3614987131335NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.m869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3614988131335NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3614989131335NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3614990131335NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3614991131335NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3614992131335NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3614993131335NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3614994131335None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3614995131335None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3614996131335NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3614997131335NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3614998131335NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3614999131335NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3615000131335NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3615001131335NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3615002131335NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3615003131335NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3615004131335NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3615005131335NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3615006131335NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3615007131335NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3615008131335NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3615009131335None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3615010131335NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3615011131335NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3615012131335None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3615013131335NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3615014131335None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.7294.35FalseNoneNoneFalseNoneFalse1199916.8820
3615015131335None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3615016131335None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3615017131335None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3615018131335None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3615019131335None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3615020131335None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3615021131335None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3615022131335None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3615023131335None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3615024131335None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3615025131335None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3615026131335None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3615027131335None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3615028131335None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3615029131335None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3615030131335None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3615031131335None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3615032131335None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3615033131335None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3615034131335None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3615035131335None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3615036131335None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3615037131335None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3615038131335None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3615039131335NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum130.1130.160.0FalseNoneNoneFalseNoneFalse7806.00
3615040131335NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum2922.82922.830.0FalseNoneNoneFalseNoneFalse87684.00
3615041131335NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum6095.886095.8820.0FalseNoneNoneFalseNoneFalse121917.60
3615042131335NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11107.6411107.6440.0FalseNoneNoneFalseNoneFalse444305.60
3615043131335NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3615044131335NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3615045131335NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each296.12296.12100.0FalseNoneNoneFalseNoneFalse29612.00
3615046131335None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7702.867702.861.2FalseNoneNoneFalseNoneFalse9243.4320
3615047131335None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9156.769156.766.48FalseNoneNoneFalseNoneFalse59335.80480
3615048131335None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm459.67459.67192.0FalseNoneNoneFalseNoneFalse88256.640
3615049131335None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm220.54220.54192.0FalseNoneNoneFalseNoneFalse42343.680
3615050131335None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3615051131335None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3615052131335NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3615053131335None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3615054131335None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3615055131335NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3615056131335NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3615057131335None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3615058131335None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3615059131335None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3615060131335NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3615061131335NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3615062131335NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3615063131335NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3615064131335NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3615065131335NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3615066131335NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3615067131335NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3615068131335None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3615069131335NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3615070131335NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3615071131335NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3615072131335NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3615073131335NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3615074131335NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3615075131335None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3615076131335NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3615077131335NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3615078131335None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3615079131335None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3615080131335None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3615081131335None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
3615082131335None1.23Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum3323.03323.0164.36FalseNoneNoneFalseNoneFalse546168.280
3615083131335NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3615084131335NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3615085131335NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3615086131335NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3615087131335NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3615088131335NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3615089131335NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3615090131335NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3615091131335NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3615092131335NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3615093131335NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3615094131335NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3615095131335NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3615096131335NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3615097131335NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3615098131335NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3615099131335NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3615100131335NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3615101131335NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3615102131335NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3615103131335NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3615104131335NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3615105131335NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3615106131335NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3615107131335NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3615108131335NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3615109131335NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3615110131335NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3615111131335NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3615112131335NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3615113131335NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3615114131335Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3615115131335NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3615116131335NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Ltr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3615117131335NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3615118131335NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3615119131335NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3615120131335NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3615121131335NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3615122131335NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3615123131335NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3615124131335NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3615125131335NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3615126131335NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3615127131335NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3615128131335NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3615129131335NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3615130131335None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3615131131335None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3615132131335None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3615133131335None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3615134131335None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3615135131335NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3615136131335None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3615137131335NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3615138131335NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3615139131335NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3615140131335NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3615141131335NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3615142131335NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3615143131335NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3615144131335NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3615145131335NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3615146131335NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3615147131335None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3615148131335None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3615149131335NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3615150131335None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3615151131335None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3615152131335None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
3615153131335NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3615154131335NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Pack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3615155131335NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3615156131335NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3615157131335NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3615158131335NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3615159131335NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3615160131335NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3615161131335NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3615162131335NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3615163131335NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3615164131335NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3615165131335NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3615166131335NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3615167131335NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3615168131335NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3615169131335NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3615170131335NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3615171131335NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3615172131335NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3615173131335NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3615174131335NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3615175131335NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3615176131335NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3615177131335NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3615178131335NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3615179131335NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3615180131335NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3615181131335NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3615182131335NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3615183131335NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3615184131335NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3615185131335NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3615186131335NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3615187131335NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3615188131335NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3615189131335NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3615190131335NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3615191131335NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3615192131335NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3615193131335None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3615194131335None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3615195131335None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3615196131335None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3615197131335None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3615198131335NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3615199131335NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3615200131335NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3615201131335NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3615202131335NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3615203131335NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3615204131335NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3615205131335NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3615206131335NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3615207131335NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3615208131335NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3615209131335NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3615210131335NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3615211131335NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3615212131335NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3615213131335NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3615214131335None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3615215131335None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3615216131335None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3615217131335None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3615218131335None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3615219131335None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3615220131335None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3615221131335None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3615222131335None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3615223131335None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3615224131335None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3615225131335None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3615226131335None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3615227131335None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3615228131335None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3615229131335None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3615230131335None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3615231131335None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3615232131335None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3615233131335None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3615234131335None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3615235131335None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3615236131335None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3615237131335None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3615238131335None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3615239131335Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3615240131335None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3615241131335None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3615242131335None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3615243131335None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3615244131335None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3615245131335None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3615246131335NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3615247131335NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3615248131335NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3615249131335NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3615250131335NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3615251131335NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3615252131335NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3615253131335NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3615254131335NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3615255131335NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3615256131335NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3615257131335NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3615258131335None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3615259131335None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3615260131335None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3615261131335None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3615262131335None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3615263131335None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3615264131335None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3615265131335None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3615266131335None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3615267131335None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3615268131335None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3615269131335None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3615270131335None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3615271131335None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3615272131335None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3615273131335None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3615274131335None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3615275131335None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3615276131335None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.MT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3615277131335None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3615278131335None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3615279131335None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3615280131335None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3615281131335None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3615282131335None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3615283131335None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3615284131335None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3615285131335None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3615286131335None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3615287131335None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3615288131335None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3615289131335None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3615290131335None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3615291131335NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3615292131335NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3615293131335None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3615294131335None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3615295131335None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3615296131335Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3615297131335Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3615298131335Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3615299131335Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3615300131335None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3615301131335Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3615302131335None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3615303131335None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218879420000NoneNoneBuildingsBAGALWADA IN MANVI TALUK RAICHUR DIST (CIVIL WORKS)27725914.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3615304131336NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.100 Sqm486.93486.9317.49FalseNoneNoneFalseNoneFalse8516.40570
3615305131336NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum117.71117.71768.64FalseNoneNoneFalseNoneFalse90476.61440
3615306131336NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum126.38126.38809.88FalseNoneNoneFalseNoneFalse102352.63440
3615307131336NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum449.76449.76583.66FalseNoneNoneFalseNoneFalse262506.92160
3615308131336NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum167.27167.27225.13FalseNoneNoneFalseNoneFalse37657.49510
3615309131336NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3615310131336NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum329.57329.57305.66FalseNoneNoneFalseNoneFalse100736.36620
3615311131336NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum587.29587.291082.02FalseNoneNoneFalseNoneFalse635459.52580
3615312131336NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7420.377420.37161.37FalseNoneNoneFalseNoneFalse1197425.10690
3615313131336NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3615314131336NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3615315131336NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.4152.43FalseNoneNoneFalseNoneFalse755695.08630
3615316131336NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3615317131336NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3615318131336NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Tonne110837.22110837.2250.48FalseNoneNoneFalseNoneFalse5595062.86560
3615319131336None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3615320131336NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3615321131336NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3615322131336NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1623.091623.091313.93FalseNoneNoneFalseNoneFalse2132626.64370
3615323131336NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3615324131336NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3615325131336NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3615326131336None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3615327131336None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3615328131336None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3615329131336None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3615330131336None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3615331131336None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3615332131336NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3615333131336None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3615334131336NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3615335131336NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3615336131336NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3615337131336NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3615338131336NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.m869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3615339131336NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3615340131336NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3615341131336NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3615342131336NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3615343131336NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3615344131336NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3615345131336None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3615346131336None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3615347131336NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3615348131336NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3615349131336NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3615350131336NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3615351131336NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3615352131336NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3615353131336NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3615354131336NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3615355131336NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3615356131336NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3615357131336NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3615358131336NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3615359131336NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3615360131336None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3615361131336NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3615362131336NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3615363131336None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3615364131336NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3615365131336None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72102.35FalseNoneNoneFalseNoneFalse1301658.6420
3615366131336None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3615367131336None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3615368131336None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3615369131336None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3615370131336None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3615371131336None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3615372131336None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3615373131336None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3615374131336None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3615375131336None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3615376131336None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3615377131336None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3615378131336None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3615379131336None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3615380131336None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3615381131336None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3615382131336None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3615383131336None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3615384131336None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3615385131336None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3615386131336None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3615387131336None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3615388131336None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3615389131336None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3615390131336NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum130.1130.172.0FalseNoneNoneFalseNoneFalse9367.20
3615391131336NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3615392131336NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum6095.886095.8824.0FalseNoneNoneFalseNoneFalse146301.120
3615393131336NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11107.6411107.6448.0FalseNoneNoneFalseNoneFalse533166.720
3615394131336NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3615395131336NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3615396131336NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3615397131336None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7702.867702.862.0FalseNoneNoneFalseNoneFalse15405.720
3615398131336None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9156.769156.7610.8FalseNoneNoneFalseNoneFalse98893.0080
3615399131336None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm459.67459.67320.0FalseNoneNoneFalseNoneFalse147094.40
3615400131336None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm220.54220.54320.0FalseNoneNoneFalseNoneFalse70572.80
3615401131336None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3615402131336None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3615403131336NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3615404131336None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3615405131336None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3615406131336NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3615407131336NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3615408131336None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3615409131336None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3615410131336None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3615411131336NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3615412131336NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3615413131336NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3615414131336NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3615415131336NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3615416131336NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3615417131336NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3615418131336NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3615419131336None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3615420131336NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3615421131336NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3615422131336NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3615423131336NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3615424131336NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3615425131336NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3615426131336None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3615427131336NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3615428131336NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3615429131336None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3615430131336None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3615431131336None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3615432131336None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
17218879430000NoneNoneBuildingsBAGALWADA IN MANVI TALUK RAICHUR DIST (WATER SUPPLY AND SANITARY WORKS)2711710.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3615433131337NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3615434131337NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3615435131337NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3615436131337NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3615437131337NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3615438131337NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3615439131337NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3615440131337NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3615441131337NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3615442131337NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3615443131337NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3615444131337NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3615445131337NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3615446131337NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3615447131337NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3615448131337NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3615449131337NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3615450131337NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3615451131337NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3615452131337NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3615453131337NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3615454131337NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3615455131337NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3615456131337NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3615457131337NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3615458131337NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3615459131337NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3615460131337NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3615461131337NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3615462131337NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3615463131337NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3615464131337Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3615465131337NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3615466131337NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Ltr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3615467131337NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3615468131337NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3615469131337NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3615470131337NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3615471131337NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3615472131337NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3615473131337NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3615474131337NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3615475131337NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3615476131337NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3615477131337NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3615478131337NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3615479131337NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3615480131337None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3615481131337None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3615482131337None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3615483131337None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3615484131337None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3615485131337NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3615486131337None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3615487131337NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3615488131337NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3615489131337NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3615490131337NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3615491131337NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3615492131337NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3615493131337NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3615494131337NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3615495131337NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3615496131337NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3615497131337None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3615498131337None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3615499131337NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3615500131337None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3615501131337None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3615502131337None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
17218879430000NoneNoneBuildingsBAGALWADA IN MANVI TALUK RAICHUR DIST (ELECTRICAL WORKS)4364380.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3615503131338NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3615504131338NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Pack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3615505131338NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3615506131338NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3615507131338NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3615508131338NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3615509131338NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3615510131338NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3615511131338NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3615512131338NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3615513131338NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3615514131338NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3615515131338NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3615516131338NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3615517131338NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3615518131338NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3615519131338NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3615520131338NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3615521131338NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3615522131338NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3615523131338NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3615524131338NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3615525131338NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3615526131338NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3615527131338NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3615528131338NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3615529131338NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3615530131338NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3615531131338NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3615532131338NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3615533131338NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3615534131338NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3615535131338NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3615536131338NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3615537131338NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3615538131338NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3615539131338NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3615540131338NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3615541131338NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3615542131338NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3615543131338None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3615544131338None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3615545131338None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3615546131338None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3615547131338None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3615548131338NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3615549131338NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3615550131338NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3615551131338NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3615552131338NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3615553131338NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3615554131338NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3615555131338NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3615556131338NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3615557131338NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3615558131338NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3615559131338NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3615560131338NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3615561131338NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3615562131338NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3615563131338NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3615564131338None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3615565131338None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3615566131338None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3615567131338None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3615568131338None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3615569131338None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3615570131338None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3615571131338None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3615572131338None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3615573131338None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3615574131338None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3615575131338None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3615576131338None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3615577131338None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3615578131338None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3615579131338None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3615580131338None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3615581131338None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3615582131338None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3615583131338None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3615584131338None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3615585131338None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3615586131338None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3615587131338None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3615588131338None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3615589131338Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3615590131338None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3615591131338None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3615592131338None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3615593131338None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3615594131338None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3615595131338None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3615596131338NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3615597131338NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3615598131338NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3615599131338NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3615600131338NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3615601131338NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3615602131338NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3615603131338NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3615604131338NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3615605131338NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3615606131338NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3615607131338NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3615608131338None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3615609131338None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3615610131338None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3615611131338None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3615612131338None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3615613131338None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3615614131338None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3615615131338None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3615616131338None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3615617131338None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3615618131338None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3615619131338None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3615620131338None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3615621131338None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3615622131338None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3615623131338None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3615624131338None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3615625131338None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3615626131338None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.MT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3615627131338None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3615628131338None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3615629131338None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3615630131338None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3615631131338None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3615632131338None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3615633131338None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3615634131338None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3615635131338None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3615636131338None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3615637131338None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3615638131338None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3615639131338None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3615640131338None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3615641131338NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3615642131338NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3615643131338None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3615644131338None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3615645131338None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3615646131338Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3615647131338Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3615648131338Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3615649131338Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3615650131338None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3615651131338Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3615652131338None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3615653131338None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218879430000NoneNoneBuildingsMAVINABHAVI IN LINGASUGUR TALUK OF RAICHUR DISTRICT.34802005.85
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3615654131339NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.100 Sqm486.93486.9317.49FalseNoneNoneFalseNoneFalse8516.40570
3615655131339NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum117.71117.71768.64FalseNoneNoneFalseNoneFalse90476.61440
3615656131339NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum126.38126.38809.88FalseNoneNoneFalseNoneFalse102352.63440
3615657131339NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum449.76449.76583.66FalseNoneNoneFalseNoneFalse262506.92160
3615658131339NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum167.27167.27225.13FalseNoneNoneFalseNoneFalse37657.49510
3615659131339NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3615660131339NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum329.57329.57305.66FalseNoneNoneFalseNoneFalse100736.36620
3615661131339NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum587.29587.291082.02FalseNoneNoneFalseNoneFalse635459.52580
3615662131339NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7420.377420.37161.37FalseNoneNoneFalseNoneFalse1197425.10690
3615663131339NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3615664131339NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3615665131339NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.4152.43FalseNoneNoneFalseNoneFalse755695.08630
3615666131339NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3615667131339NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3615668131339NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Tonne110837.22110837.2250.48FalseNoneNoneFalseNoneFalse5595062.86560
3615669131339None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3615670131339NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3615671131339NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3615672131339NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1623.091623.091313.93FalseNoneNoneFalseNoneFalse2132626.64370
3615673131339NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3615674131339NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3615675131339NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3615676131339None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3615677131339None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3615678131339None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3615679131339None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3615680131339None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3615681131339None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3615682131339NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3615683131339None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3615684131339NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3615685131339NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3615686131339NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3615687131339NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3615688131339NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.m869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3615689131339NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3615690131339NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3615691131339NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3615692131339NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3615693131339NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3615694131339NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3615695131339None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3615696131339None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3615697131339NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3615698131339NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3615699131339NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3615700131339NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3615701131339NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3615702131339NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3615703131339NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3615704131339NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3615705131339NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3615706131339NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3615707131339NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3615708131339NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3615709131339NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3615710131339None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3615711131339NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3615712131339NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3615713131339None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3615714131339NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3615715131339None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72102.35FalseNoneNoneFalseNoneFalse1301658.6420
3615716131339None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3615717131339None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3615718131339None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3615719131339None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3615720131339None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3615721131339None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3615722131339None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3615723131339None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3615724131339None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3615725131339None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3615726131339None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3615727131339None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3615728131339None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3615729131339None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3615730131339None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3615731131339None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3615732131339None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3615733131339None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3615734131339None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3615735131339None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3615736131339None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3615737131339None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3615738131339None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3615739131339None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3615740131339NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum130.1130.172.0FalseNoneNoneFalseNoneFalse9367.20
3615741131339NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3615742131339NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum6095.886095.8824.0FalseNoneNoneFalseNoneFalse146301.120
3615743131339NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11107.6411107.6448.0FalseNoneNoneFalseNoneFalse533166.720
3615744131339NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3615745131339NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3615746131339NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3615747131339None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7702.867702.862.0FalseNoneNoneFalseNoneFalse15405.720
3615748131339None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9156.769156.7610.8FalseNoneNoneFalseNoneFalse98893.0080
3615749131339None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm459.67459.67320.0FalseNoneNoneFalseNoneFalse147094.40
3615750131339None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm220.54220.54320.0FalseNoneNoneFalseNoneFalse70572.80
3615751131339None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3615752131339None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3615753131339NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3615754131339None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3615755131339None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3615756131339NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3615757131339NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3615758131339None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3615759131339None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3615760131339None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3615761131339NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3615762131339NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3615763131339NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3615764131339NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3615765131339NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3615766131339NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3615767131339NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3615768131339NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3615769131339None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3615770131339NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3615771131339NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3615772131339NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3615773131339NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3615774131339NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3615775131339NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3615776131339None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3615777131339NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3615778131339NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3615779131339None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3615780131339None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3615781131339None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3615782131339None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
3615783131339NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3615784131339NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3615785131339NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3615786131339NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3615787131339NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3615788131339NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3615789131339NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3615790131339NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3615791131339NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3615792131339NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3615793131339NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3615794131339NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3615795131339NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3615796131339NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3615797131339NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3615798131339NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3615799131339NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3615800131339NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3615801131339NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3615802131339NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3615803131339NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3615804131339NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3615805131339NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3615806131339NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3615807131339NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3615808131339NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3615809131339NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3615810131339NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3615811131339NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3615812131339NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3615813131339NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3615814131339Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3615815131339NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3615816131339NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Ltr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3615817131339NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3615818131339NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3615819131339NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3615820131339NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3615821131339NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3615822131339NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3615823131339NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3615824131339NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3615825131339NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3615826131339NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3615827131339NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3615828131339NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3615829131339NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3615830131339None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3615831131339None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3615832131339None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3615833131339None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3615834131339None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3615835131339NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3615836131339None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3615837131339NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3615838131339NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3615839131339NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3615840131339NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3615841131339NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3615842131339NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3615843131339NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3615844131339NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3615845131339NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3615846131339NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3615847131339None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3615848131339None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3615849131339NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3615850131339None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3615851131339None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3615852131339None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
3615853131339NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3615854131339NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Pack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3615855131339NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3615856131339NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3615857131339NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3615858131339NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3615859131339NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3615860131339NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3615861131339NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3615862131339NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3615863131339NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3615864131339NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3615865131339NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3615866131339NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3615867131339NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3615868131339NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3615869131339NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3615870131339NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3615871131339NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3615872131339NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3615873131339NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3615874131339NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3615875131339NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3615876131339NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3615877131339NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3615878131339NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3615879131339NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3615880131339NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3615881131339NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3615882131339NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3615883131339NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3615884131339NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3615885131339NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3615886131339NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3615887131339NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3615888131339NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3615889131339NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3615890131339NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3615891131339NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3615892131339NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3615893131339None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3615894131339None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3615895131339None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3615896131339None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3615897131339None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3615898131339NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3615899131339NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3615900131339NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3615901131339NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3615902131339NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3615903131339NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3615904131339NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3615905131339NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3615906131339NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3615907131339NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3615908131339NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3615909131339NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3615910131339NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3615911131339NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3615912131339NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3615913131339NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3615914131339None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3615915131339None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3615916131339None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3615917131339None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3615918131339None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3615919131339None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3615920131339None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3615921131339None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3615922131339None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3615923131339None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3615924131339None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3615925131339None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3615926131339None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3615927131339None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3615928131339None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3615929131339None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3615930131339None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3615931131339None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3615932131339None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3615933131339None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3615934131339None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3615935131339None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3615936131339None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3615937131339None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3615938131339None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3615939131339Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3615940131339None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3615941131339None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3615942131339None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3615943131339None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3615944131339None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3615945131339None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3615946131339NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3615947131339NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3615948131339NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3615949131339NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3615950131339NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3615951131339NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3615952131339NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3615953131339NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3615954131339NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3615955131339NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3615956131339NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3615957131339NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3615958131339None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3615959131339None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3615960131339None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3615961131339None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3615962131339None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3615963131339None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3615964131339None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3615965131339None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3615966131339None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3615967131339None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3615968131339None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3615969131339None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3615970131339None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3615971131339None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3615972131339None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3615973131339None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3615974131339None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3615975131339None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3615976131339None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.MT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3615977131339None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3615978131339None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3615979131339None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3615980131339None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3615981131339None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3615982131339None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3615983131339None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3615984131339None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3615985131339None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3615986131339None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3615987131339None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3615988131339None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3615989131339None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3615990131339None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3615991131339NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3615992131339NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3615993131339None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3615994131339None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3615995131339None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3615996131339Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3615997131339Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3615998131339Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3615999131339Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3616000131339None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3616001131339Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3616002131339None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3616003131339None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218879430000NoneNoneBuildingsMUSTOOR IN DEODURG TALUK OF RAICHUR DISTRICT34812473.11
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3616004131340NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.100 Sqm486.93486.9317.09FalseNoneNoneFalseNoneFalse8321.63370
3616005131340NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum117.71117.71540.95FalseNoneNoneFalseNoneFalse63675.22450
3616006131340NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum126.38126.381430.43FalseNoneNoneFalseNoneFalse180777.74340
3616007131340NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum449.76449.76254.05FalseNoneNoneFalseNoneFalse114261.5280
3616008131340NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum167.27167.27218.94FalseNoneNoneFalseNoneFalse36622.09380
3616009131340NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3616010131340NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum329.57329.57901.41FalseNoneNoneFalseNoneFalse297077.69370
3616011131340NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum587.29587.29747.04FalseNoneNoneFalseNoneFalse438729.12160
3616012131340NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7420.377420.37155.33FalseNoneNoneFalseNoneFalse1152606.07210
3616013131340NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3616014131340NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3616015131340NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.4157.58FalseNoneNoneFalseNoneFalse829924.14780
3616016131340NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3616017131340NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3616018131340NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Tonne110837.22110837.2250.59FalseNoneNoneFalseNoneFalse5607254.95980
3616019131340None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3616020131340NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3616021131340NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3616022131340NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1623.091623.091253.93FalseNoneNoneFalseNoneFalse2035241.24370
3616023131340NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3616024131340NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3616025131340NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3616026131340None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3616027131340None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3616028131340None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3616029131340None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3616030131340None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3616031131340None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3616032131340NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3616033131340None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3616034131340NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3616035131340NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3616036131340NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3616037131340NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3616038131340NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.m869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3616039131340NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3616040131340NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3616041131340NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3616042131340NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3616043131340NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3616044131340NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3616045131340None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3616046131340None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3616047131340NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3616048131340NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3616049131340NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3616050131340NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3616051131340NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3616052131340NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3616053131340NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3616054131340NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3616055131340NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3616056131340NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3616057131340NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3616058131340NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3616059131340NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3616060131340None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3616061131340NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3616062131340NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3616063131340None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3616064131340NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3616065131340None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.7294.35FalseNoneNoneFalseNoneFalse1199916.8820
3616066131340None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3616067131340None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3616068131340None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3616069131340None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3616070131340None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3616071131340None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3616072131340None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3616073131340None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3616074131340None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3616075131340None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3616076131340None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3616077131340None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3616078131340None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3616079131340None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3616080131340None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3616081131340None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3616082131340None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3616083131340None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3616084131340None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3616085131340None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3616086131340None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3616087131340None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3616088131340None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3616089131340None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3616090131340NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum130.1130.160.0FalseNoneNoneFalseNoneFalse7806.00
3616091131340NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum2922.82922.830.0FalseNoneNoneFalseNoneFalse87684.00
3616092131340NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum6095.886095.8820.0FalseNoneNoneFalseNoneFalse121917.60
3616093131340NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11107.6411107.6440.0FalseNoneNoneFalseNoneFalse444305.60
3616094131340NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3616095131340NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3616096131340NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each296.12296.12100.0FalseNoneNoneFalseNoneFalse29612.00
3616097131340None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7702.867702.861.2FalseNoneNoneFalseNoneFalse9243.4320
3616098131340None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9156.769156.766.48FalseNoneNoneFalseNoneFalse59335.80480
3616099131340None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm459.67459.67192.0FalseNoneNoneFalseNoneFalse88256.640
3616100131340None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm220.54220.54192.0FalseNoneNoneFalseNoneFalse42343.680
3616101131340None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3616102131340None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3616103131340NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3616104131340None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3616105131340None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3616106131340NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3616107131340NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3616108131340None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3616109131340None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3616110131340None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3616111131340NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3616112131340NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3616113131340NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3616114131340NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3616115131340NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3616116131340NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3616117131340NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3616118131340NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3616119131340None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3616120131340NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3616121131340NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3616122131340NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3616123131340NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3616124131340NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3616125131340NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3616126131340None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3616127131340NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3616128131340NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3616129131340None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3616130131340None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3616131131340None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3616132131340None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
3616133131340None1.23Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum3323.03323.0164.36FalseNoneNoneFalseNoneFalse546168.280
3616134131340NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3616135131340NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3616136131340NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3616137131340NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3616138131340NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3616139131340NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3616140131340NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3616141131340NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3616142131340NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3616143131340NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3616144131340NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3616145131340NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3616146131340NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3616147131340NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3616148131340NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3616149131340NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3616150131340NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3616151131340NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3616152131340NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3616153131340NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3616154131340NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3616155131340NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3616156131340NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3616157131340NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3616158131340NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3616159131340NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3616160131340NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3616161131340NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3616162131340NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3616163131340NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3616164131340NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3616165131340Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3616166131340NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3616167131340NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Ltr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3616168131340NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3616169131340NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3616170131340NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3616171131340NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3616172131340NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3616173131340NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3616174131340NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3616175131340NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3616176131340NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3616177131340NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3616178131340NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3616179131340NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3616180131340NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3616181131340None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3616182131340None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3616183131340None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3616184131340None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3616185131340None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3616186131340NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3616187131340None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3616188131340NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3616189131340NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3616190131340NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3616191131340NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3616192131340NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3616193131340NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3616194131340NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3616195131340NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3616196131340NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3616197131340NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3616198131340None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3616199131340None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3616200131340NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3616201131340None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3616202131340None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3616203131340None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
3616204131340NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3616205131340NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Pack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3616206131340NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3616207131340NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3616208131340NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3616209131340NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3616210131340NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3616211131340NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3616212131340NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3616213131340NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3616214131340NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3616215131340NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3616216131340NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3616217131340NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3616218131340NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3616219131340NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3616220131340NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3616221131340NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3616222131340NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3616223131340NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3616224131340NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3616225131340NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3616226131340NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3616227131340NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3616228131340NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3616229131340NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3616230131340NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3616231131340NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3616232131340NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3616233131340NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3616234131340NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3616235131340NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3616236131340NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3616237131340NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3616238131340NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3616239131340NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3616240131340NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3616241131340NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3616242131340NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3616243131340NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3616244131340None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3616245131340None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3616246131340None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3616247131340None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3616248131340None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3616249131340NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3616250131340NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3616251131340NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3616252131340NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3616253131340NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3616254131340NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3616255131340NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3616256131340NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3616257131340NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3616258131340NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3616259131340NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3616260131340NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3616261131340NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3616262131340NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3616263131340NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3616264131340NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3616265131340None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3616266131340None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3616267131340None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3616268131340None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3616269131340None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3616270131340None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3616271131340None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3616272131340None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3616273131340None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3616274131340None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3616275131340None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3616276131340None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3616277131340None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3616278131340None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3616279131340None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3616280131340None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3616281131340None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3616282131340None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3616283131340None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3616284131340None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3616285131340None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3616286131340None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3616287131340None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3616288131340None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3616289131340None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3616290131340Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3616291131340None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3616292131340None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3616293131340None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3616294131340None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3616295131340None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3616296131340None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3616297131340NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3616298131340NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3616299131340NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3616300131340NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3616301131340NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3616302131340NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3616303131340NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3616304131340NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3616305131340NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3616306131340NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3616307131340NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3616308131340NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3616309131340None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3616310131340None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3616311131340None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3616312131340None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3616313131340None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3616314131340None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3616315131340None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3616316131340None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3616317131340None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3616318131340None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3616319131340None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3616320131340None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3616321131340None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3616322131340None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3616323131340None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3616324131340None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3616325131340None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3616326131340None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3616327131340None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.MT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3616328131340None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3616329131340None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3616330131340None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3616331131340None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3616332131340None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3616333131340None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3616334131340None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3616335131340None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3616336131340None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3616337131340None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3616338131340None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3616339131340None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3616340131340None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3616341131340None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3616342131340NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3616343131340NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3616344131340None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3616345131340None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3616346131340None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3616347131340Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3616348131340Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3616349131340Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3616350131340Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3616351131340None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3616352131340Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3616353131340None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3616354131340None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218879430000NoneNoneBuildingsGAUDURU IN LINGASUGUR TALUK OF RAICHUR DISTRICT.34802005.85
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3616355131341NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.100 Sqm486.93486.9317.49FalseNoneNoneFalseNoneFalse8516.40570
3616356131341NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum117.71117.71768.64FalseNoneNoneFalseNoneFalse90476.61440
3616357131341NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum126.38126.38809.88FalseNoneNoneFalseNoneFalse102352.63440
3616358131341NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum449.76449.76583.66FalseNoneNoneFalseNoneFalse262506.92160
3616359131341NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum167.27167.27225.13FalseNoneNoneFalseNoneFalse37657.49510
3616360131341NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3616361131341NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum329.57329.57305.66FalseNoneNoneFalseNoneFalse100736.36620
3616362131341NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum587.29587.291082.02FalseNoneNoneFalseNoneFalse635459.52580
3616363131341NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7420.377420.37161.37FalseNoneNoneFalseNoneFalse1197425.10690
3616364131341NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3616365131341NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3616366131341NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.4152.43FalseNoneNoneFalseNoneFalse755695.08630
3616367131341NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3616368131341NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3616369131341NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Tonne110837.22110837.2250.48FalseNoneNoneFalseNoneFalse5595062.86560
3616370131341None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3616371131341NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3616372131341NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3616373131341NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1623.091623.091313.93FalseNoneNoneFalseNoneFalse2132626.64370
3616374131341NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3616375131341NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3616376131341NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3616377131341None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3616378131341None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3616379131341None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3616380131341None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3616381131341None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3616382131341None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3616383131341NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3616384131341None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3616385131341NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3616386131341NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3616387131341NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3616388131341NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3616389131341NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.m869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3616390131341NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3616391131341NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3616392131341NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3616393131341NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3616394131341NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3616395131341NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3616396131341None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3616397131341None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3616398131341NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3616399131341NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3616400131341NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3616401131341NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3616402131341NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3616403131341NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3616404131341NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3616405131341NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3616406131341NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3616407131341NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3616408131341NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3616409131341NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3616410131341NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3616411131341None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3616412131341NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3616413131341NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3616414131341None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3616415131341NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3616416131341None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72102.35FalseNoneNoneFalseNoneFalse1301658.6420
3616417131341None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3616418131341None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3616419131341None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3616420131341None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3616421131341None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3616422131341None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3616423131341None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3616424131341None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3616425131341None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3616426131341None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3616427131341None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3616428131341None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3616429131341None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3616430131341None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3616431131341None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3616432131341None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3616433131341None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3616434131341None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3616435131341None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3616436131341None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3616437131341None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3616438131341None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3616439131341None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3616440131341None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3616441131341NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum130.1130.172.0FalseNoneNoneFalseNoneFalse9367.20
3616442131341NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3616443131341NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum6095.886095.8824.0FalseNoneNoneFalseNoneFalse146301.120
3616444131341NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum11107.6411107.6448.0FalseNoneNoneFalseNoneFalse533166.720
3616445131341NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3616446131341NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3616447131341NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3616448131341None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum7702.867702.862.0FalseNoneNoneFalseNoneFalse15405.720
3616449131341None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9156.769156.7610.8FalseNoneNoneFalseNoneFalse98893.0080
3616450131341None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm459.67459.67320.0FalseNoneNoneFalseNoneFalse147094.40
3616451131341None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm220.54220.54320.0FalseNoneNoneFalseNoneFalse70572.80
3616452131341None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3616453131341None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3616454131341NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3616455131341None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3616456131341None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3616457131341NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3616458131341NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3616459131341None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3616460131341None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3616461131341None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3616462131341NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3616463131341NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3616464131341NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3616465131341NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3616466131341NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3616467131341NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3616468131341NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3616469131341NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3616470131341None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Nos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3616471131341NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3616472131341NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3616473131341NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3616474131341NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3616475131341NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3616476131341NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3616477131341None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3616478131341NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3616479131341NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3616480131341None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3616481131341None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3616482131341None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3616483131341None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
3616484131341NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3616485131341NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3616486131341NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3616487131341NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3616488131341NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3616489131341NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3616490131341NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3616491131341NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3616492131341NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3616493131341NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3616494131341NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3616495131341NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3616496131341NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3616497131341NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3616498131341NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3616499131341NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3616500131341NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3616501131341NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3616502131341NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3616503131341NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3616504131341NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3616505131341NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3616506131341NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3616507131341NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3616508131341NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3616509131341NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3616510131341NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3616511131341NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3616512131341NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3616513131341NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3616514131341NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3616515131341Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3616516131341NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3616517131341NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Ltr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3616518131341NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3616519131341NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3616520131341NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3616521131341NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3616522131341NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3616523131341NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3616524131341NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3616525131341NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3616526131341NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3616527131341NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3616528131341NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3616529131341NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3616530131341NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3616531131341None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3616532131341None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Unit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3616533131341None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3616534131341None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3616535131341None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3616536131341NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3616537131341None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3616538131341NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3616539131341NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3616540131341NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3616541131341NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3616542131341NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3616543131341NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Cum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3616544131341NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3616545131341NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3616546131341NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3616547131341NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3616548131341None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3616549131341None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3616550131341NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3616551131341None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3616552131341None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3616553131341None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
3616554131341NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3616555131341NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Pack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3616556131341NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3616557131341NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3616558131341NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3616559131341NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3616560131341NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3616561131341NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3616562131341NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3616563131341NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3616564131341NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3616565131341NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3616566131341NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3616567131341NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3616568131341NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3616569131341NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3616570131341NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3616571131341NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3616572131341NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3616573131341NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3616574131341NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3616575131341NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3616576131341NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3616577131341NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3616578131341NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3616579131341NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3616580131341NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3616581131341NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3616582131341NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3616583131341NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3616584131341NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3616585131341NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3616586131341NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3616587131341NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3616588131341NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3616589131341NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3616590131341NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3616591131341NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3616592131341NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3616593131341NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3616594131341None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3616595131341None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3616596131341None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3616597131341None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3616598131341None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3616599131341NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3616600131341NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3616601131341NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3616602131341NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3616603131341NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3616604131341NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3616605131341NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3616606131341NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3616607131341NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3616608131341NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3616609131341NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3616610131341NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3616611131341NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3616612131341NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3616613131341NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3616614131341NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3616615131341None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3616616131341None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3616617131341None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3616618131341None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3616619131341None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3616620131341None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3616621131341None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3616622131341None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3616623131341None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3616624131341None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3616625131341None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3616626131341None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3616627131341None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3616628131341None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3616629131341None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3616630131341None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3616631131341None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3616632131341None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3616633131341None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Point1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3616634131341None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3616635131341None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3616636131341None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3616637131341None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3616638131341None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3616639131341None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3616640131341Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3616641131341None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3616642131341None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3616643131341None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3616644131341None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3616645131341None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3616646131341None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3616647131341NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3616648131341NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3616649131341NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Job300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3616650131341NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3616651131341NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3616652131341NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3616653131341NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3616654131341NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3616655131341NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3616656131341NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3616657131341NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3616658131341NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3616659131341None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3616660131341None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3616661131341None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3616662131341None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3616663131341None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3616664131341None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3616665131341None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3616666131341None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3616667131341None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3616668131341None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3616669131341None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3616670131341None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3616671131341None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3616672131341None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3616673131341None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3616674131341None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3616675131341None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3616676131341None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3616677131341None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.MT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3616678131341None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3616679131341None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3616680131341None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3616681131341None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3616682131341None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3616683131341None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3616684131341None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Sq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3616685131341None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3616686131341None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3616687131341None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3616688131341None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3616689131341None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3616690131341None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3616691131341None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3616692131341NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3616693131341NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Rmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3616694131341None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3616695131341None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3616696131341None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Each173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3616697131341Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3616698131341Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3616699131341Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3616700131341Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3616701131341None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.No59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3616702131341Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Set73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3616703131341None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3616704131341None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Km5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17218879460000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17218879460000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17218879460001NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17218879460000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17218879460000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17218880680000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17218880840000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17218881040000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17218881470000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17218881550000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17218881610000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17218881680000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17218881730000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17218881800000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17218881850000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17218881910000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17218881970000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17218882030000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17218882090000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17218882150000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17218882190000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17218882240000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17218882290000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21 2021-22, 2022-23 & 2023-24.None
17218882350000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
17218902850000NoneNoneELIGIBILITYThe bidder should upload ESI and EPF certificateNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No Position Qualification and Requirement No of Persons. (1) Project Manager B.E. Civil with minimum experience of 15 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years. 1 (One) (2)Site Engineer B.E. Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years. 6 (Six), (3)Electrical Engineer B.E. Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 2 (Two).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates should be uploaded
NoneNoneNoneNoneKPWD Class-I Registration Certificate.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- REGISTRATION CERTIFICATE ISSUED BY COMPETENT AUTHORITY
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least one Similar work of value not less than Rs.2086.50 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24).Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation 25872.00 Cum,2)RCC and PCC 8428.00Cum, 3)Steel Reinforcement for RCC work 486.00 tonne, 4)Cement Concrete Block Masonry/Solid Block Masonry/BBM/Load Bearing Wall 14534.00Sqm, 5)Flooring/Dadooing(Vitrified/Granite/Ceramic/Cement concrete/cladding/dadooing) 10600.00Sqm, 6)Plastering 45266.00 Sqm, 7)Painting 40744.00 Sqm, 8) MS Girls 15368.00 kgs, 9)WPC 8800.00 Sqm. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2(c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24). The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.262.00 Lakhs in any one financial year.Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d).The letter of willingness of the sub contractor to be engaged for electrical, should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(e) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24). The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.163.00 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e).The letter of willingness of the sub contractor to be engaged for water supply & Sanitary, should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2019-20 to 2023-24 updated to 2024-25 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2024-25 price level of existing commitments and ongoing works to be completed during the next 18 months. Note The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- list of existing commitments and on-going works
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.751.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneClause ITT 3.3 (a)Equipment capacity Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50% can be deployed on ease/hire basis for all works provided, the relevant documents (commitment agreements etc.,) for availability for this work are furnished. Sl.No. Description of Equipment Quantity 1) Min 10 cft capacity Concrete Mixer -4Nos, 2) Centering sheets-5000 Sqmtr, 3) Tipper-4 Nos, 4) Water Tanker-8Nos, 5) Bar Bending and cutting machine-4Nos, 6) Excavator-3 NosCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Invoices and receipt to be uploaded
NoneNoneNoneNoneClause ITT 3.2(a):To qualify for award of this contract, each Tenderer in his / its name should have in the last five years i.e.(2019-20 to 2023-24).The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs. 5564.00 Lakhs. Note: For Clause 3.2 (a) the Turn over certificate and balance sheet duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate and balance sheet certified by charted accountant along with UDIN numberTrueTechnical Bid
Workdone certificate issued by the officer not below the rank of EETrueTechnical Bid
KPWD Class-I Registration Certificate.TrueTechnical Bid
ESI and PF certificate and latest paid receiptTrueTechnical Bid
GST certificate & latest paid receiptTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1721891669000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, HFWD, Arogya Soudha, 3rd Floor, 1st Cross Magadi Road
streetNone
cityBengalruu
stateKarnataka
pin560023
tenderRecallDTONone