1721733713000 | 0 | None | None | Roads | Comprehensive Development of Roads & Drains In Kushal Nagar HB Layout P&T Colony Muslim Colony Water Tank In W No70 Kushalnagar Basappa Lane Cr Rd AK Colony Cr Rd Modi Road 1 to 5 Cr Rd Modi Road 6 to 10 Cr Rd Goa Garden Cr Rd & In W No 78 SK Garden Bilal Nagar Main Road RamaBai Colony Davis & Kandaswami Main Road 12 13 14 Giddappa Block In W No79 Sagayapuram & Additional Works to Construction of Multipurpose Building in ward office premises in w no74 KB Sandra Package no 01 GO Sl No1 2 6 4 Anx4 | 127683163.31 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3591564 | 130749 | None | code01 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (V-I, Item No.2.1.6, Page No.15) | Cum | 6867.3 | 6867.3 | 32.76 | False | None | None | False | None | False | 224972.748 | 0 | 3591565 | 130749 | None | code02 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy dut tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. (V-II, Item No.9.40, Page No.65) | Sqm | 1025.2 | 1025.2 | 327.6 | False | None | None | False | None | False | 335855.52 | 0 | 3591566 | 130749 | None | code03 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (V-II, Item No.8.30, Page No.46) | Sqm | 191.4 | 191.4 | 192.43 | False | None | None | False | None | False | 36831.102 | 0 | 3591567 | 130749 | None | code04 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (V-II, Item No.8.30, Page No.46) | Sqm | 193.31 | 193.31 | 177.22 | False | None | None | False | None | False | 34258.3982 | 0 | 3591568 | 130749 | None | code05 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (V-II, Item No.8.30, Page No.46) | Sqm | 195.23 | 195.23 | 206.66 | False | None | None | False | None | False | 40346.2318 | 0 | 3591569 | 130749 | None | code06 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (V-II, Item No.8.30, Page No.46) | Sqm | 197.14 | 197.14 | 207.02 | False | None | None | False | None | False | 40811.9228 | 0 | 3591570 | 130749 | None | code07 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (V-II, Item No.8.30, Page No.46) | Sqm | 199.06 | 199.06 | 314.66 | False | None | None | False | None | False | 62636.2196 | 0 | 3591571 | 130749 | None | code08 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(V-II, Item No.8.51, Page No.50) | Sqm | 110.0 | 110.0 | 367.03 | False | None | None | False | None | False | 40373.3 | 0 | 3591572 | 130749 | None | code09 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(V-II, Item No.8.51, Page No.50) | Sqm | 111.1 | 111.1 | 676.41 | False | None | None | False | None | False | 75149.151 | 0 | 3591573 | 130749 | None | code10 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(V-II, Item No.8.51, Page No.50) | Sqm | 112.2 | 112.2 | 826.02 | False | None | None | False | None | False | 92679.444 | 0 | 3591574 | 130749 | None | code11 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(V-II, Item No.8.51, Page No.50) | Sqm | 113.3 | 113.3 | 833.24 | False | None | None | False | None | False | 94406.092 | 0 | 3591575 | 130749 | None | code12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(V-II, Item No.8.51, Page No.50) | Sqm | 114.4 | 114.4 | 80.16 | False | None | None | False | None | False | 9170.304 | 0 | 3591576 | 130749 | None | code13 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (KPWD SR 2023-24, V-II, Item No.8.33.1, Page No.46) | Sqm | 173.8 | 173.8 | 367.03 | False | None | None | False | None | False | 63789.814 | 0 | 3591577 | 130749 | None | code14 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (KPWD SR 2023-24, V-II, Item No.8.33.1, Page No.46) | Sqm | 175.54 | 175.54 | 676.41 | False | None | None | False | None | False | 118737.0114 | 0 | 3591578 | 130749 | None | code15 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (KPWD SR 2023-24, V-II, Item No.8.33.1, Page No.46) | Sqm | 177.28 | 177.28 | 826.02 | False | None | None | False | None | False | 146436.8256 | 0 | 3591579 | 130749 | None | code16 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (KPWD SR 2023-24, V-II, Item No.8.33.1, Page No.46) | Sqm | 179.01 | 179.01 | 833.24 | False | None | None | False | None | False | 149158.2924 | 0 | 3591580 | 130749 | None | code17 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (KPWD SR 2023-24, V-II, Item No.8.33.1, Page No.46) | Sqm | 180.75 | 180.75 | 80.16 | False | None | None | False | None | False | 14488.92 | 0 | 3591581 | 130749 | None | code18 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(KPWD SR 2023-24, V-II, Item No.8.40, Page No.48) | Sqm | 126.5 | 126.5 | 87.3 | False | None | None | False | None | False | 11043.45 | 0 | 3591582 | 130749 | None | code19 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resist ance as per ASTM E119- 2 and clause B, S1, do as per ENT 13501-1sand wiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete. For Straight Portion (V-II, Item No.10.15.1, Page No.71) | Sqm | 4387.9 | 4387.9 | 435.48 | False | None | None | False | None | False | 1910842.692 | 0 | 3591583 | 130749 | None | code20 | Providing & fixing of 2 track x 2-panel sliding windows made out of multi chambered UPVC Matching to RAL-9016 sections and with minimum TiO2 Titanium Dioxide at 6 PHR with TPE Thermo Plastic Elastomer and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm The cost is inclusive of all fixtures and separate charges for minor T&P s shall not be made (V-II Item No.12.84 Page No.108) | Sqm | 5525.3 | 5525.3 | 435.48 | False | None | None | False | None | False | 2406157.644 | 0 | 3591584 | 130749 | None | code21 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (V-II, Item No.11.34A, Page No.86) | Kg | 184.8 | 184.8 | 11017.86 | False | None | None | False | None | False | 2036100.528 | 0 | 3591585 | 130749 | None | code22 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of the slab upto 0.50 m2 (V-II, Item No.10.1.1, Page No.69) | Sqm | 4406.6 | 4406.6 | 395.76 | False | None | None | False | None | False | 1743956.016 | 0 | 3591586 | 130749 | None | code23 | Design, supplying, erecting testing and commissioning of - Passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries,voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665/2016 ( with latest amendments) part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. (Vol-VI Page-59, Item-14.2.2) 8 Passengers, 4 Stops | Job | 1520607.0 | 1520607.0 | 1.0 | False | None | None | False | None | False | 1520607.0 | 0 | 3591587 | 130749 | None | code24 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. (V-II, Item No.10.14, Page No.71) | Sqm | 1216.6 | 1216.6 | 18.27 | False | None | None | False | None | False | 22227.282 | 0 | 3591588 | 130749 | None | code25 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (V-II, Item No.12.11, Page No.99) | Sqm | 1746.8 | 1746.8 | 28.35 | False | None | None | False | None | False | 49521.78 | 0 | 3591589 | 130749 | None | code26 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (V-II, Item No.12.11, Page No.99) | Cum | 151881.4 | 151881.4 | 0.54 | False | None | None | False | None | False | 82015.956 | 0 | 3591590 | 130749 | None | code27 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per
specifications. ( excluding cost of fixtures )(V-II, Item No.12.15, Page No.100) | Sqm | 8188.4 | 8188.4 | 10.08 | False | None | None | False | None | False | 82539.072 | 0 | 3591591 | 130749 | None | code28 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )(V-II, Item No.12.15, Page No.100) | Sqm | 8188.4 | 8188.4 | 10.08 | False | None | None | False | None | False | 82539.072 | 0 | 3591592 | 130749 | None | code29 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (Volume-II, Item No.14.2.1, Page No.131) | Each | 5321.8 | 5321.8 | 16.0 | False | None | None | False | None | False | 85148.8 | 0 | 3591593 | 130749 | None | code30 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern (Volume-II, Item No.14.4.1, Page No.131) | Each | 4899.4 | 4899.4 | 10.0 | False | None | None | False | None | False | 48994.0 | 0 | 3591594 | 130749 | None | code31 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps (Volume-II, Item No.14.7.1, Page No.132) | Each | 3390.2 | 3390.2 | 10.0 | False | None | None | False | None | False | 33902.0 | 0 | 3591595 | 130749 | None | code32 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (Volume-II, Item No.13.34, Page No.122) | Ltr | 9.9 | 9.9 | 2000.0 | False | None | None | False | None | False | 19800.0 | 0 | 3591596 | 130749 | None | code33 | Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete- Class. Premium (Volume-II, Item No.14.55(b), Page No.139) | No | 2668.6 | 2668.6 | 30.0 | False | None | None | False | None | False | 80058.0 | 0 | 3591597 | 130749 | None | code34 | Providing and fixing Angle cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class Premium (Volume-II, Item No.14.54(b), Page No.139) | No | 2109.8 | 2109.8 | 30.0 | False | None | None | False | None | False | 63294.0 | 0 | 3591598 | 130749 | None | code35 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour 15 mm nominal bore with 450 mm length (Volume-II, Item No.13.27.2, Page No.120) | No | 127.6 | 127.6 | 30.0 | False | None | None | False | None | False | 3828.0 | 0 | 3591599 | 130749 | None | code36 | Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Premium (Volume-II, Item No.14.62(b), Page No.140) | No | 3174.6 | 3174.6 | 10.0 | False | None | None | False | None | False | 31746.0 | 0 | 3591600 | 130749 | None | code37 | Providing and fixing Towel rail 600mm length made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete- Class a Economy (Volume-II, Item No.14.89a, Page No.144) | No | 1388.2 | 1388.2 | 10.0 | False | None | None | False | None | False | 13882.0 | 0 | 3591601 | 130749 | None | code38 | Providing and fixing Toilet paper holder made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete- Class a Economy (Volume-II, Item No.14.93a, Page No.145) | No | 922.9 | 922.9 | 10.0 | False | None | None | False | None | False | 9229.0 | 0 | 3591602 | 130749 | None | code39 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm (Volume-II, Item No.14.32.2, Page No.136) | Each | 1119.8 | 1119.8 | 5.0 | False | None | None | False | None | False | 5599.0 | 0 | 3591603 | 130749 | None | code40 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay (non modular) bricks of class designation 3.5, (150 mm nominal dia Pipes) (Volume-II, Item No.13.51, Page No.125) | Each | 1876.6 | 1876.6 | 4.0 | False | None | None | False | None | False | 7506.4 | 0 | 3591604 | 130749 | None | code41 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments.2 HP, Size 65x50 Head 13M, Discharge 462 LPM (BWSSB SR Volume-V, Item No.13.40.1, Page No.157) | Each | 17171.0 | 17171.0 | 1.0 | False | None | None | False | None | False | 17171.0 | 0 | 3591605 | 130749 | None | code42 | Making soak pit 2.5 m diameter 3.0 m deep with 45 x 45 cm dry brick honey comb shaft with bricks and PVC S.W.R drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay (non modular) bricks of class designation 3.5 (Volume-2, Item No.13.56, Page No.127) | Each | 25326.4 | 25326.4 | 1.0 | False | None | None | False | None | False | 25326.4 | 0 | 3591606 | 130749 | None | code43 | Demolishing brick work manually/ by mechanical means including stack ing of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar (Volume-2, Item No.19.7.3, Page No.187) | Sqm | 1131.9 | 1131.9 | 9.0 | False | None | None | False | None | False | 10187.1 | 0 | 3591607 | 130749 | None | code44 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200 mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Volume-2, Item No.6.32, Page No.17) | Sqm | 1441.0 | 1441.0 | 45.0 | False | None | None | False | None | False | 64845.0 | 0 | 3591608 | 130749 | None | code45 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Volume-2, Item No.8.4.1, Page No.41) | Sqm | 355.3 | 355.3 | 90.0 | False | None | None | False | None | False | 31977.0 | 0 | 3591609 | 130749 | None | code46 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (Volume-1, Item No.2.1.6, Page No.15) | Cum | 6867.3 | 6867.3 | 27.0 | False | None | None | False | None | False | 185417.1 | 0 | 3591610 | 130749 | None | code47 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 kVA ON LINE UPS (Volume-6, Item No.9.3.5, Page No.38) | Each | 103570.0 | 103570.0 | 4.0 | False | None | None | False | None | False | 414280.0 | 0 | 3591611 | 130749 | None | code48 | Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A /R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 1.5 Ton capacity (Volume-6, Item No.6.8.5, Page No.31) | Each | 56355.0 | 56355.0 | 4.0 | False | None | None | False | None | False | 225420.0 | 0 | 3591612 | 130749 | None | code49 | Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame. (Volume-2, Item No.7.28.1, Page No.24) | Sqm | 1401.4 | 1401.4 | 49.0 | False | None | None | False | None | False | 68668.6 | 0 | 3591613 | 130749 | None | code50 | Extra for sunk or raised mouldings in the plaster of Paris (Gypsum anhydrous) ceiling. (Volume-2, Item No.7.29, Page No.24) | Sqm | 499.4 | 499.4 | 49.0 | False | None | None | False | None | False | 24470.6 | 0 | 3591614 | 130749 | None | code51 | Providing, fabricating and fixing of 10 mm thick Decorative Grooved Bamboo Wood Wall cladding with panel size 1220mmx2440mm, thermal insulation value 2.2 J/g oC & having density 1300kg/m3. The base material shall be of MDF and the surface of Bamboo shall be coated with Graphene based PU Coating. The material shall possess special properties such as
Fire resistant, Thermal insulation, Sound absorbent and UV & Water resist ant. The panel shall be fixed on walls using Mild steel screws or by using special adhesives as per direction of Engineer in charge. (Volume-2, Item No.10.26, Page No.79) | Sqm | 2227.5 | 2227.5 | 142.67 | False | None | None | False | None | False | 317797.425 | 0 | 3591615 | 130749 | None | code52 | Providing and laying linoleum plain flooring or coloured 3.2mm thick sheet / tiles laid with an approved adhesive on sub floor stretching, cutting and fixing complete , including cost of materials, labour, complete as per specifications. (Volume-2, Item No.9.33, Page No.64) | Sqm | 994.4 | 994.4 | 49.0 | False | None | None | False | None | False | 48725.6 | 0 | 3591616 | 130749 | None | code53 | Dismantling tile work in floors and roofs laid in cement mortar includ ing stacking material to the appropriate disposal area as per direction of Engineer-in-charge. (Volume-2, Item No.19.22.1, Page No.189) | Sqm | 52.8 | 52.8 | 98.56 | False | None | None | False | None | False | 5203.968 | 0 | 3591617 | 130749 | None | code54 | Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in charge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification) (Volume-3, Item No.6.8.1, Page No.51) | Sqm | 1174.8 | 1174.8 | 78.1 | False | None | None | False | None | False | 91751.88 | 0 | 3591618 | 130749 | None | code55 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. e) 6Moudule (Vol: 6 Page-8, Item-3.5.4) | Each | 234.0 | 234.0 | 40.0 | False | None | None | False | None | False | 9360.0 | 0 | 3591619 | 130749 | None | code56 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. e) 6Moudule (Vol: 6 Page-8, Item-3.5.5) | Each | 284.0 | 284.0 | 30.0 | False | None | None | False | None | False | 8520.0 | 0 | 3591620 | 130749 | None | code57 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. e) 6Moudule (Vol: 6 Page-8, Item-3.5.6) | Each | 344.0 | 344.0 | 80.0 | False | None | None | False | None | False | 27520.0 | 0 | 3591621 | 130749 | None | code58 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate. (Vol: 6, Page-9, Item-3.6) | Each | 102.0 | 102.0 | 200.0 | False | None | None | False | None | False | 20400.0 | 0 | 3591622 | 130749 | None | code59 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate. (Vol: 6, Page-9, Item-3.6) | Each | 166.0 | 166.0 | 50.0 | False | None | None | False | None | False | 8300.0 | 0 | 3591623 | 130749 | None | code60 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate. (Vol: 6, Page-9, Item-3.6) | Each | 357.0 | 357.0 | 40.0 | False | None | None | False | None | False | 14280.0 | 0 | 3591624 | 130749 | None | code61 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate. (Vol: 6, Page-9, Item-3.6) | Each | 180.0 | 180.0 | 15.0 | False | None | None | False | None | False | 2700.0 | 0 | 3591625 | 130749 | None | code62 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate. (Vol: 6, Page-9, Item-3.6) | Each | 326.0 | 326.0 | 15.0 | False | None | None | False | None | False | 4890.0 | 0 | 3591626 | 130749 | None | code63 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate. (Vol: 6, Page-9, Item-3.6) | Each | 236.0 | 236.0 | 15.0 | False | None | None | False | None | False | 3540.0 | 0 | 3591627 | 130749 | None | code64 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate. (Vol: 6, Page-9, Item-3.6) | Each | 156.0 | 156.0 | 15.0 | False | None | None | False | None | False | 2340.0 | 0 | 3591628 | 130749 | None | code65 | Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts, 50Hz AC supply &completely wired on existing box (Vol: 6, Page-9, Item-3.7) | Each | 646.0 | 646.0 | 15.0 | False | None | None | False | None | False | 9690.0 | 0 | 3591629 | 130749 | None | code66 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. a. 1 sqmm. (Vol:6, Page-5, Item-2.3.1) | m | 19.0 | 19.0 | 500.0 | False | None | None | False | None | False | 9500.0 | 0 | 3591630 | 130749 | None | code67 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. a. 1 sqmm. (Vol:6, Page-5, Item-2.3.2) | m | 26.0 | 26.0 | 7000.0 | False | None | None | False | None | False | 182000.0 | 0 | 3591631 | 130749 | None | code68 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. a. 1 sqmm. (Vol:6, Page-5, Item-2.3.3) | m | 42.0 | 42.0 | 2000.0 | False | None | None | False | None | False | 84000.0 | 0 | 3591632 | 130749 | None | code69 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. a. 1 sqmm. (Vol:5, Page-9, Item-2.3) | m | 63.0 | 63.0 | 1500.0 | False | None | None | False | None | False | 94500.0 | 0 | 3591633 | 130749 | None | code70 | Supplying and drawing PVC insulated flexible copper wire of approved make as per IS: 694: 2010 (Vol: 6,Page-6, Item-2.4.3)40/0.0040" | m | 29.0 | 29.0 | 50.0 | False | None | None | False | None | False | 1450.0 | 0 | 3591634 | 130749 | None | code71 | Providing main connection from pole PVC insulated sheathed steel wire cable in GI pipe as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. (Volume-V Page-156, Item-13.37) | m | 148.5 | 148.5 | 80.0 | False | None | None | False | None | False | 11880.0 | 0 | 3591635 | 130749 | None | code72 | Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (Volume-V Page-156, Item-13.39) | Job | 3750.0 | 3750.0 | 3.0 | False | None | None | False | None | False | 11250.0 | 0 | 3591636 | 130749 | None | code73 | Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. . (Volume-V Page-156, Item-13.35.3) | m | 195.0 | 195.0 | 80.0 | False | None | None | False | None | False | 15600.0 | 0 | 3591637 | 130749 | None | code74 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2.(Vol: 6, Page-17, Item-5.17.3) | Each | 15529.0 | 15529.0 | 1.0 | False | None | None | False | None | False | 15529.0 | 0 | 3591638 | 130749 | None | code75 | Supplying and fixing of PVC casing and capping on the wall or ceilng using necessary materials like bends, screws at an interval of 300mm …. Etc as required. a) 20mm (Vol:5, Page-3, Item-1.8.1) | m | 28.0 | 28.0 | 100.0 | False | None | None | False | None | False | 2800.0 | 0 | 3591639 | 130749 | None | code76 | Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size 110mm conduit using necessary machine screws. b) 110mm (Vol:5, Page-9, Item-3.10.3) | m | 21.0 | 21.0 | 500.0 | False | None | None | False | None | False | 10500.0 | 0 | 3591640 | 130749 | None | code77 | Supplying of 1 x 4 feet -PVC Batten with integrated LED tube - 20/22 W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition (Vol:6, Page-43, Item-11.3.2) | Each | 690.0 | 690.0 | 100.0 | False | None | None | False | None | False | 69000.0 | 0 | 3591641 | 130749 | None | code78 | Supply of round/square recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminum with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W (Vol 6, Page-44, Item-11.5.2) | Each | 885.0 | 885.0 | 60.0 | False | None | None | False | None | False | 53100.0 | 0 | 3591642 | 130749 | None | code79 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty. 48" Sweep 5 Star (1200 mm) (Vol:5, Page-30, Item-6.4.1) | Each | 2677.0 | 2677.0 | 40.0 | False | None | None | False | None | False | 107080.0 | 0 | 3591643 | 130749 | None | code80 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. (Vol:5, Page-57, Item-13.10) | Each | 171.0 | 171.0 | 40.0 | False | None | None | False | None | False | 6840.0 | 0 | 3591644 | 130749 | None | code81 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion (V-II, Item No.10.15.1, Page No.71) | Sqm | 4711.01 | 4711.01 | 156.81 | False | None | None | False | None | False | 738733.4781 | 0 | 3591645 | 130749 | None | code82 | Providing and supplying 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc. complete as per direction of Engineer-in-charge. (Volume-II, Item No.22.6, Page No.217) | Sqm | 1221.0 | 1221.0 | 62.52 | False | None | None | False | None | False | 76336.92 | 0 | 3591646 | 130749 | None | code83 | Providing and fixing stainless steel 304 grade fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-incharge. (Volume-II, Item No.22.9a, Page No.218) | Sqm | 1650.0 | 1650.0 | 50.0 | False | None | None | False | None | False | 82500.0 | 0 | 3591647 | 130749 | None | code84 | Providing and fixing stainless steel 304 grade fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-incharge. 100 mm length (Volume-II, Item No.22.9c, Page No.218) | Nos | 1210.0 | 1210.0 | 50.0 | False | None | None | False | None | False | 60500.0 | 0 | 3591648 | 130749 | None | code85 | Providing and fixing Stainless Steel 304 grade soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge.. (Volume-II, Item No.22.10, Page No.218) | Nos | 440.0 | 440.0 | 30.0 | False | None | None | False | None | False | 13200.0 | 0 | 3591649 | 130749 | None | code86 | Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge (Volume-II, Item No.22.11, Page No.218) | Nos | 286.0 | 286.0 | 40.0 | False | None | None | False | None | False | 11440.0 | 0 | 3591650 | 130749 | None | code87 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.(Volume-II, Item No.13.48, Page No.125) | m | 320.1 | 320.1 | 60.0 | False | None | None | False | None | False | 19206.0 | 0 | 3591651 | 130749 | None | code88 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes (KPWD SR 2023-24, Volume-II, Item No.13.31.3, Page No.122) | m | 349.8 | 349.8 | 30.0 | False | None | None | False | None | False | 10494.0 | 0 | 3591652 | 130749 | None | code89 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes (Volume-II, Item No.13.31.4, Page No.122) | m | 440.0 | 440.0 | 30.0 | False | None | None | False | None | False | 13200.0 | 0 | 3591653 | 130749 | None | code90 | Electrical TC Connection | Each | 1500000.0 | 1500000.0 | 1.0 | False | None | None | False | None | False | 1500000.0 | 0 | 3591654 | 130749 | None | code91 | Removing & Refixing stone slabs of drains and pointing in C.M (1:3) (Approved rate by Yelahanka Zone Dt: 18/06/2022) | Sqm | 121.0 | 121.0 | 3164.18 | False | None | None | False | None | False | 382865.78 | 0 | 3591655 | 130749 | None | code92 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth (Item No 1.5.1 (Vol-I) Page No 6) | Cum | 251.9 | 251.9 | 895.4 | False | None | None | False | None | False | 225551.26 | 0 | 3591656 | 130749 | None | code93 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No 6.32 (Vol-II) Page No 17) | Sqm | 1441.0 | 1441.0 | 1588.0 | False | None | None | False | None | False | 2288308.0 | 0 | 3591657 | 130749 | None | code94 | Providing Flush / Ruled/ Struck or weathered pointing Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineerin-charge. (Item No 8.17.1 (Vol-II) Page No 44) | Sqm | 189.2 | 189.2 | 1588.0 | False | None | None | False | None | False | 300449.6 | 0 | 3591658 | 130749 | None | code95 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (Item No 2.1.6 (Vol-I) Page No 15) | Cum | 6867.3 | 6867.3 | 459.59 | False | None | None | False | None | False | 3156142.407 | 0 | 3591659 | 130749 | None | code96 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (Item No 1.4.1 (Vol-I) Page No 5) | Cum | 266.2 | 266.2 | 448.2 | False | None | None | False | None | False | 119310.84 | 0 | 3591660 | 130749 | None | code97 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (Item No 2.1.2 (Vol-I) Page No 15) | Cum | 6230.4 | 6230.4 | 74.7 | False | None | None | False | None | False | 465410.88 | 0 | 3591661 | 130749 | None | code98 | Providing and laying in position Cement Concrete for all Foundation works. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No 2.2.1 (Vol-I) Page No 15) | Cum | 6915.7 | 6915.7 | 161.85 | False | None | None | False | None | False | 1119306.045 | 0 | 3591662 | 130749 | None | code99 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures (Item No 2.11h (Vol-I) Page No 18) | t | 86912.1 | 86912.1 | 11.33 | False | None | None | False | None | False | 984714.093 | 0 | 3591663 | 130749 | None | code100 | Providing and laying Pre Cast Slab using 20mm and down size aggregate stone using clean seived approved sand including cost and conveyance of all materials, all lead and lift, labour charges of machinery etc., complete of 10cm thick as directed buy Engineer-in Charge CC1:2:4 (Inclusive of cost of steel and fabrication charges) (As per data rate) | Sqm | 2072.0 | 2072.0 | 1427.85 | False | None | None | False | None | False | 2958505.2 | 0 | 3591664 | 130749 | None | code101 | Providing and laying Pre Cast Slab using 20mm and down size aggregate stone using clean seived approved sand including cost and conveyance of all materials, all lead and lift, labour charges of machinery etc., complete of 23cm thick as directed buy Engineer-in Charge CC1:2:4 (Inclusive of cost of steel and fabrication charges) (As per data rate) | Cum | 5037.0 | 5037.0 | 51.98 | False | None | None | False | None | False | 261823.26 | 0 | 3591665 | 130749 | None | code102 | Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable materials separately(Item No 2.19 (Vol-III) Page No 12) | Cum | 619.3 | 619.3 | 7997.69 | False | None | None | False | None | False | 4952969.417 | 0 | 3591666 | 130749 | None | code103 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth (Item No 1.12 (Vol-1) Page No 8) | Cum | 104.5 | 104.5 | 5708.53 | False | None | None | False | None | False | 596541.385 | 0 | 3591667 | 130749 | None | code104 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m (Item No 1.6.1 (Vol-1) Page No 6) | Cum | 532.4 | 532.4 | 673.94 | False | None | None | False | None | False | 358805.656 | 0 | 3591668 | 130749 | None | code105 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal dia Pipes (Item No 13.33.6 (Vol-2) Page No 123) | m | 793.1 | 793.1 | 3328.1 | False | None | None | False | None | False | 2639516.11 | 0 | 3591669 | 130749 | None | code106 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. (Item No 4.17 (Vol-3) Page No 26) | Cum | 2814.9 | 2814.9 | 2077.52 | False | None | None | False | None | False | 5848011.048 | 0 | 3591670 | 130749 | None | code107 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 14:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 140 kg/ m3 , optimum moisture content to be determined during trial length construction, concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. (Item No 6.1 (Vol-3) Page No 49) | Cum | 5412.0 | 5412.0 | 3458.85 | False | None | None | False | None | False | 18719296.2 | 0 | 3591671 | 130749 | None | code108 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383:2016:, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant, curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. (Item No: 16.28 (Vol-III) Page No: 149) | Cum | 7429.4 | 7429.4 | 2833.75 | False | None | None | False | None | False | 21053062.25 | 0 | 3591672 | 130749 | None | code109 | Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broom (Item No: 5.3 (Vol-5) Page No: 31) | Sqm | 13.2 | 13.2 | 48638.96 | False | None | None | False | None | False | 642034.272 | 0 | 3591673 | 130749 | None | code110 | Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/m2 using mechanical means. (Item No: 5.1 (Vol-3) Page No: 31) | Sqm | 45.1 | 45.1 | 4354.18 | False | None | None | False | None | False | 196373.518 | 0 | 3591674 | 130749 | None | code111 | Providing and laying Dense Graded Bituminous Macadam with 40/60 TPH capacity hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-30, @ 4.0 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects. (Item No: 5.10c (Vol-5) Page No: 34) | Cum | 9656.9 | 9656.9 | 539.38 | False | None | None | False | None | False | 5208738.722 | 0 | 3591675 | 130749 | None | code112 | Providing and laying Bituminous Concrete with 40/60 TPH capacity hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 5.2 percent of mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects (Item No: 5.14c (Vol-5) Page No: 36) | Cum | 11688.6 | 11688.6 | 1838.71 | False | None | None | False | None | False | 21491945.706 | 0 | 3591676 | 130749 | None | code113 | Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 g/m2 area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35:2015.The finished surface to be level, uniform and free from streaks and holes. (Item No: 8.15 (Vol-5) Page No: 67) | Sqm | 583.0 | 583.0 | 1209.16 | False | None | None | False | None | False | 704940.28 | 0 | 3591677 | 130749 | None | code114 | Removing and resetting of kerb stones (Approved rate analysis datarate) | m | 118.0 | 118.0 | 3367.8 | False | None | None | False | None | False | 397400.4 | 0 | 3591678 | 130749 | None | code115 | Providing and fixing pre cast solid cement concrete kerb stones made out of C.C. 1:2:4 with top and bottom width 114 and 165 mm respectively, 400mm high and 450mm in length finished with CM 1:3 plastering and finishing cutting, including form work, curing, including cost of all materials, labour, hire charges of machinery, loading, unloading, lead and lift, transportation etc., complete. (Approved rate by Yelahanka Zone Dt: 18/06/2022) | Nos | 507.0 | 507.0 | 1872.0 | False | None | None | False | None | False | 949104.0 | 0 | 3591679 | 130749 | None | code116 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces(Item No 8.10 (Vol-III) Page No 56) | Sqm | 93.5 | 93.5 | 1290.65 | False | None | None | False | None | False | 120675.775 | 0 | 3591680 | 130749 | None | code117 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/ Kankar /Moorum. (Tipper 5.5 m3) ( Volume III , Item No : 1.1A , Page No : ) | Cum | 165.72 | 165.72 | 15723.77 | False | None | None | False | None | False | 2605743.1644 | 0 | 3591681 | 130749 | None | code118 | Supply and fixing of childern Multi Play Equipment with curved silde, tunnel and side panels: Upright structural posts of height 2.2m, 2.4m are to be HOT DIP Galvanized steel with a 114mm OD and 2.2mm (wall) thickness of the tubing The poles are welded on to a base plate made from steel with 114mm inner diameter. Deck of size 1.45 x 1.45m, Impending stairs of size 0.80m x 0.60m and 1.05 m x 0.68 m are fabricated from 2mm perforated solid punched steel along with a curved Slide of size 1.7m x 1.8m x 1.2m Coupled with the tunnel are made of super thick plasticwhich shelle be animated and rotationally molded from antistatic, copolymer, virgin(( LLDPE ) which is UV stabilized with color molded in and minimum thickness of 6-8mm. Unit consist of Deck of size 1.45 x 1.45m and Staircase of size 1.74 m x 1.32 m along with Triple Slide of size 3.95m x 2.93m x 1.80m with stairs, Plastic Components (super thick plastic] shall be animated and shall be rotationally molded from antistatic, copolymer, virgin linear low density UV stabilized polyethylene, with color molded in and minimum thickness of 6-8mm.Roof of size 2.00m x 1.78m, Spiral tube Slide of size 3.2 m x 1.82mx 2.7m along with Monkey loop climber 1.87m x 1.15m x 0.6m which has thickness of 48 mm curved bar supports are all robotic welded fabricated from 32 O.D. GI pipes for the outer pipes and 25mm O.D. Also consisting of Deck of size 1.45 x 1.45m Plastic Components shall be animated and shall be rotationally molded from antistatic, copolymer, virgin linear low density UV stabilized polyethylene, with color molded in and minimum thickness of 6-8mm. The rates are to be inclusive of supply and installation at site. Inclusive of All Taxes and Transportation Charges | Each | 3879484.0 | 3879484.0 | 2.0 | False | None | None | False | None | False | 7758968.0 | 0 | 3591682 | 130749 | None | code119 | Supply and fixing of childern Multi Play Equipment with curved slide and number panel: Upright structural posts of height 2.4 m, 2.7 m, 3.3 m schedule HOT DIP Galvanized steel with a 114mm OD and 2.2mm (wall) thickness of the tubing. All metal components are to be finished with a baked on powder coat finish. With deck of size 1.45 x 1.45m and Staircase of size 1.5m x 0.77 m are fabricated from 2mm perforated solid punched steel. Deck perimeter is precision pre punched for attachments. Decks are pressed, punched, and welded sand blasted and vinyl plastic coated to a thickness of 4mm. Along with Handrail of height 2.2 m and Dia 32 mm shall be an all- robotic welded unit, fabricated from 32 O.D. galvanized steel pipes with a baked on powder coating finish.Curved Slide of size 1.94 m x 1.85 m x 2.4 m, Panels, Toprails Of Monkey loop of size 1.8 m x 1.3 m.Deck of size 1.45 x 1.45m are fabricated from 2mm perforated solid punched steel. Deck perimeter is precision pre punched for attachments. Decks are pressed, punched, and welded sand blasted and vinyl plastic coated to a thickness of 4mm. Roof of size Dia 2 m and height 0.82 m, Spiral Slide of size 1.16 m x 1.6 m x 3.6 m, Panels The rates are to be inclusive of supply and installation at site. Inclusive of All Taxes and Transportation Charges | Each | 2201295.0 | 2201295.0 | 2.0 | False | None | None | False | None | False | 4402590.0 | 0 |
|