createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721828233220
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd2434000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose26-08-2024 16:00:00
tenderQueryClose17-08-2024 15:00:00
technicalBidOpen27-08-2024 16:30:00
publishedDate25-07-2024 12:18:31
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate19-08-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonAssistant Engineer
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9449843375
tenderSupplierListNone
tenderSchedule
createdTs1721828233248
version7
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT541
titleConstruction of Primary Health center (H type) at 1)Mudbull in Shahapur taluk 2)Mudnoor, 3)Malaghathi, 4)Narayanapur, 5)Khanpur SH, 6)Heggandoddi and 7)Thinthini in Shorapur taluk of Yadgir District.
descriptionConstruction of Primary Health center (H type) at 1)Mudbull in Shahapur taluk 2)Mudnoor, 3)Malaghathi, 4)Narayanapur, 5)Khanpur SH, 6)Heggandoddi and 7)Thinthini in Shorapur taluk of Yadgir District.
categoryWORKS
categoryTextWorks
ecv243392083.79
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount280000000.0
groupOverheadTotal0.0
fileNumberKKRDB-2
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17218282330000NoneNoneBuildingsMUDABULL IN SHAHAPUR TALUK OF YADGIR DISTRICT. (CIVIL)27665191.48
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3609362131234NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work100 Sqm486.93486.9317.49FalseNoneNoneFalseNoneFalse8516.40570
3609363131234NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum117.71117.71768.64FalseNoneNoneFalseNoneFalse90476.61440
3609364131234NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum126.38126.381311.57FalseNoneNoneFalseNoneFalse165756.21660
3609365131234NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum449.76449.76230.53FalseNoneNoneFalseNoneFalse103683.17280
3609366131234NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum167.27167.27225.13FalseNoneNoneFalseNoneFalse37657.49510
3609367131234NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3609368131234NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum329.57329.57807.35FalseNoneNoneFalseNoneFalse266078.33950
3609369131234NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum587.29587.29728.89FalseNoneNoneFalseNoneFalse428069.80810
3609370131234NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7420.377420.37161.37FalseNoneNoneFalseNoneFalse1197425.10690
3609371131234NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3609372131234NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3609373131234NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum14413.4114413.4155.14FalseNoneNoneFalseNoneFalse794755.42740
3609374131234NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3609375131234NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3609376131234NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workTonne110837.22110837.2250.82FalseNoneNoneFalseNoneFalse5632747.52040
3609377131234None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3609378131234NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3609379131234NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3609380131234NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1623.091623.091313.93FalseNoneNoneFalseNoneFalse2132626.64370
3609381131234NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3609382131234NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3609383131234NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3609384131234None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3609385131234None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3609386131234None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3609387131234None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3609388131234None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3609389131234None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3609390131234NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3609391131234None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3609392131234NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3609393131234NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3609394131234NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3609395131234NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3609396131234NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workm869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3609397131234NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3609398131234NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3609399131234NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3609400131234NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3609401131234NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3609402131234NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3609403131234None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3609404131234None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3609405131234NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3609406131234NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3609407131234NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3609408131234NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3609409131234NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3609410131234NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3609411131234NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3609412131234NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3609413131234NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3609414131234NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3609415131234NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3609416131234NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3609417131234NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3609418131234None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3609419131234NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3609420131234NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3609421131234None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3609422131234NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3609423131234None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.72102.35FalseNoneNoneFalseNoneFalse1301658.6420
3609424131234None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3609425131234None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3609426131234None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3609427131234None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3609428131234None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3609429131234None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3609430131234None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3609431131234None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3609432131234None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3609433131234None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3609434131234None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3609435131234None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3609436131234None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3609437131234None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3609438131234None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3609439131234None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3609440131234None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3609441131234None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3609442131234None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3609443131234None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3609444131234None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3609445131234None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3609446131234None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3609447131234None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3609448131234NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum130.1130.172.0FalseNoneNoneFalseNoneFalse9367.20
3609449131234NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3609450131234NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum6095.886095.8824.0FalseNoneNoneFalseNoneFalse146301.120
3609451131234NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum11107.6411107.6448.0FalseNoneNoneFalseNoneFalse533166.720
3609452131234NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3609453131234NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3609454131234NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3609455131234None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7702.867702.862.0FalseNoneNoneFalseNoneFalse15405.720
3609456131234None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum9156.769156.7610.8FalseNoneNoneFalseNoneFalse98893.0080
3609457131234None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm459.67459.67320.0FalseNoneNoneFalseNoneFalse147094.40
3609458131234None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm220.54220.54320.0FalseNoneNoneFalseNoneFalse70572.80
3609459131234None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3609460131234None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3609461131234NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3609462131234None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3609463131234None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3609464131234NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3609465131234NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3609466131234None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3609467131234None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3609468131234None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3609469131234NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3609470131234NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3609471131234NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3609472131234NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3609473131234NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3609474131234NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3609475131234NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3609476131234NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3609477131234None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3609478131234NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3609479131234NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3609480131234NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3609481131234NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3609482131234NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3609483131234NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3609484131234None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3609485131234NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3609486131234NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3609487131234None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3609488131234None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3609489131234None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3609490131234None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
17218282330000NoneNoneBuildingsMUDABULL WATER SUPPLY AND SANITARY WORKS2711710.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3609491131235NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3609492131235NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3609493131235NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3609494131235NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3609495131235NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3609496131235NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3609497131235NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3609498131235NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3609499131235NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3609500131235NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3609501131235NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3609502131235NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3609503131235NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3609504131235NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3609505131235NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3609506131235NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3609507131235NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3609508131235NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3609509131235NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3609510131235NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3609511131235NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3609512131235NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3609513131235NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3609514131235NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3609515131235NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3609516131235NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3609517131235NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3609518131235NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3609519131235NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3609520131235NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3609521131235NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3609522131235Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3609523131235NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3609524131235NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workLtr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3609525131235NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3609526131235NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3609527131235NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3609528131235NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3609529131235NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3609530131235NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3609531131235NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3609532131235NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3609533131235NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3609534131235NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workUnit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3609535131235NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3609536131235NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3609537131235NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3609538131235None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3609539131235None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workUnit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3609540131235None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3609541131235None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3609542131235None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3609543131235NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3609544131235None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3609545131235NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3609546131235NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3609547131235NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3609548131235NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3609549131235NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3609550131235NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3609551131235NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3609552131235NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3609553131235NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3609554131235NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3609555131235None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3609556131235None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3609557131235NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3609558131235None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3609559131235None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3609560131235None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
17218282330000NoneNoneBuildingsMUDABULL ELECTRICAL WORKS4364380.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3609561131236NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3609562131236NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3609563131236NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3609564131236NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3609565131236NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3609566131236NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3609567131236NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3609568131236NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3609569131236NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3609570131236NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3609571131236NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3609572131236NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3609573131236NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3609574131236NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3609575131236NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3609576131236NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3609577131236NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3609578131236NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3609579131236NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3609580131236NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3609581131236NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3609582131236NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3609583131236NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3609584131236NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3609585131236NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3609586131236NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3609587131236NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3609588131236NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3609589131236NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3609590131236NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3609591131236NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3609592131236NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3609593131236NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3609594131236NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3609595131236NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3609596131236NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3609597131236NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3609598131236NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3609599131236NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3609600131236NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3609601131236None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3609602131236None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3609603131236None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3609604131236None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3609605131236None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3609606131236NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3609607131236NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3609608131236NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3609609131236NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3609610131236NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3609611131236NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3609612131236NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3609613131236NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3609614131236NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3609615131236NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3609616131236NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3609617131236NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3609618131236NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3609619131236NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3609620131236NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3609621131236NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3609622131236None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3609623131236None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3609624131236None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3609625131236None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3609626131236None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3609627131236None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3609628131236None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3609629131236None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3609630131236None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3609631131236None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3609632131236None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3609633131236None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3609634131236None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3609635131236None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3609636131236None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3609637131236None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3609638131236None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3609639131236None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3609640131236None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3609641131236None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3609642131236None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3609643131236None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3609644131236None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3609645131236None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3609646131236None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3609647131236Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3609648131236None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3609649131236None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3609650131236None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3609651131236None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3609652131236None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3609653131236None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3609654131236NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3609655131236NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3609656131236NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3609657131236NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3609658131236NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3609659131236NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3609660131236NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3609661131236NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3609662131236NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3609663131236NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3609664131236NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3609665131236NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3609666131236None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3609667131236None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3609668131236None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3609669131236None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3609670131236None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3609671131236None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3609672131236None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3609673131236None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3609674131236None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3609675131236None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3609676131236None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3609677131236None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3609678131236None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3609679131236None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3609680131236None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3609681131236None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3609682131236None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3609683131236None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3609684131236None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3609685131236None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3609686131236None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3609687131236None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3609688131236None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3609689131236None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3609690131236None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3609691131236None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3609692131236None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3609693131236None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3609694131236None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3609695131236None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3609696131236None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3609697131236None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3609698131236None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3609699131236NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3609700131236NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3609701131236None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3609702131236None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3609703131236None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3609704131236Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3609705131236Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3609706131236Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3609707131236Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3609708131236None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3609709131236Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3609710131236None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3609711131236None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218282330000NoneNoneBuildingsMALAGATHI IN SHORAPUR TALUK34741282.93
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3609712131237NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work100 Sqm486.93486.9317.49FalseNoneNoneFalseNoneFalse8516.40570
3609713131237NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum117.71117.71768.64FalseNoneNoneFalseNoneFalse90476.61440
3609714131237NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum126.38126.381311.57FalseNoneNoneFalseNoneFalse165756.21660
3609715131237NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum449.76449.76230.53FalseNoneNoneFalseNoneFalse103683.17280
3609716131237NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum167.27167.27225.13FalseNoneNoneFalseNoneFalse37657.49510
3609717131237NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3609718131237NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum329.57329.57807.35FalseNoneNoneFalseNoneFalse266078.33950
3609719131237NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum587.29587.29728.89FalseNoneNoneFalseNoneFalse428069.80810
3609720131237NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7420.377420.37161.37FalseNoneNoneFalseNoneFalse1197425.10690
3609721131237NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3609722131237NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3609723131237NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum14413.4114413.4155.14FalseNoneNoneFalseNoneFalse794755.42740
3609724131237NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3609725131237NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3609726131237NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workTonne110837.22110837.2250.82FalseNoneNoneFalseNoneFalse5632747.52040
3609727131237None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3609728131237NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3609729131237NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3609730131237NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1623.091623.091313.93FalseNoneNoneFalseNoneFalse2132626.64370
3609731131237NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3609732131237NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3609733131237NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3609734131237None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3609735131237None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3609736131237None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3609737131237None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3609738131237None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3609739131237None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3609740131237NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3609741131237None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3609742131237NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3609743131237NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3609744131237NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3609745131237NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3609746131237NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workm869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3609747131237NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3609748131237NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3609749131237NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3609750131237NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3609751131237NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3609752131237NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3609753131237None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3609754131237None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3609755131237NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3609756131237NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3609757131237NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3609758131237NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3609759131237NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3609760131237NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3609761131237NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3609762131237NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3609763131237NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3609764131237NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3609765131237NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3609766131237NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3609767131237NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3609768131237None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3609769131237NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3609770131237NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3609771131237None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3609772131237NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3609773131237None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.72102.35FalseNoneNoneFalseNoneFalse1301658.6420
3609774131237None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3609775131237None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3609776131237None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3609777131237None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3609778131237None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3609779131237None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3609780131237None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3609781131237None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3609782131237None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3609783131237None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3609784131237None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3609785131237None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3609786131237None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3609787131237None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3609788131237None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3609789131237None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3609790131237None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3609791131237None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3609792131237None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3609793131237None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3609794131237None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3609795131237None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3609796131237None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3609797131237None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3609798131237NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum130.1130.172.0FalseNoneNoneFalseNoneFalse9367.20
3609799131237NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3609800131237NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum6095.886095.8824.0FalseNoneNoneFalseNoneFalse146301.120
3609801131237NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum11107.6411107.6448.0FalseNoneNoneFalseNoneFalse533166.720
3609802131237NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3609803131237NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3609804131237NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3609805131237None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7702.867702.862.0FalseNoneNoneFalseNoneFalse15405.720
3609806131237None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum9156.769156.7610.8FalseNoneNoneFalseNoneFalse98893.0080
3609807131237None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm459.67459.67320.0FalseNoneNoneFalseNoneFalse147094.40
3609808131237None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm220.54220.54320.0FalseNoneNoneFalseNoneFalse70572.80
3609809131237None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3609810131237None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3609811131237NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3609812131237None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3609813131237None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3609814131237NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3609815131237NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3609816131237None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3609817131237None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3609818131237None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3609819131237NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3609820131237NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3609821131237NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3609822131237NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3609823131237NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3609824131237NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3609825131237NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3609826131237NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3609827131237None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3609828131237NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3609829131237NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3609830131237NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3609831131237NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3609832131237NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3609833131237NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3609834131237None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3609835131237NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3609836131237NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3609837131237None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3609838131237None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3609839131237None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3609840131237None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
3609841131237NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3609842131237NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3609843131237NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3609844131237NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3609845131237NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3609846131237NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3609847131237NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3609848131237NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3609849131237NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3609850131237NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3609851131237NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3609852131237NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3609853131237NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3609854131237NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3609855131237NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3609856131237NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3609857131237NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3609858131237NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3609859131237NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3609860131237NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3609861131237NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3609862131237NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3609863131237NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3609864131237NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3609865131237NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3609866131237NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3609867131237NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3609868131237NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3609869131237NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3609870131237NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3609871131237NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3609872131237Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3609873131237NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3609874131237NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workLtr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3609875131237NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3609876131237NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3609877131237NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3609878131237NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3609879131237NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3609880131237NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3609881131237NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3609882131237NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3609883131237NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3609884131237NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workUnit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3609885131237NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3609886131237NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3609887131237NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3609888131237None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3609889131237None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workUnit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3609890131237None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3609891131237None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3609892131237None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3609893131237NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3609894131237None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3609895131237NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3609896131237NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3609897131237NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3609898131237NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3609899131237NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3609900131237NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3609901131237NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3609902131237NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3609903131237NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3609904131237NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3609905131237None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3609906131237None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3609907131237NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3609908131237None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3609909131237None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3609910131237None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
3609911131237NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3609912131237NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3609913131237NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3609914131237NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3609915131237NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3609916131237NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3609917131237NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3609918131237NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3609919131237NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3609920131237NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3609921131237NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3609922131237NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3609923131237NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3609924131237NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3609925131237NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3609926131237NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3609927131237NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3609928131237NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3609929131237NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3609930131237NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3609931131237NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3609932131237NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3609933131237NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3609934131237NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3609935131237NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3609936131237NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3609937131237NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3609938131237NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3609939131237NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3609940131237NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3609941131237NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3609942131237NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3609943131237NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3609944131237NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3609945131237NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3609946131237NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3609947131237NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3609948131237NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3609949131237NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3609950131237NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3609951131237None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3609952131237None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3609953131237None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3609954131237None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3609955131237None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3609956131237NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3609957131237NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3609958131237NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3609959131237NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3609960131237NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3609961131237NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3609962131237NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3609963131237NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3609964131237NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3609965131237NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3609966131237NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3609967131237NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3609968131237NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3609969131237NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3609970131237NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3609971131237NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3609972131237None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3609973131237None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3609974131237None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3609975131237None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3609976131237None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3609977131237None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3609978131237None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3609979131237None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3609980131237None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3609981131237None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3609982131237None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3609983131237None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3609984131237None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3609985131237None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3609986131237None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3609987131237None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3609988131237None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3609989131237None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3609990131237None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3609991131237None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3609992131237None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3609993131237None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3609994131237None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3609995131237None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3609996131237None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3609997131237Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3609998131237None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3609999131237None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3610000131237None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3610001131237None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3610002131237None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3610003131237None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3610004131237NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3610005131237NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3610006131237NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3610007131237NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3610008131237NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3610009131237NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3610010131237NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3610011131237NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3610012131237NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3610013131237NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3610014131237NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3610015131237NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3610016131237None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3610017131237None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3610018131237None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3610019131237None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3610020131237None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3610021131237None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3610022131237None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3610023131237None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3610024131237None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3610025131237None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3610026131237None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3610027131237None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3610028131237None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3610029131237None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3610030131237None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3610031131237None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3610032131237None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3610033131237None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3610034131237None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3610035131237None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3610036131237None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3610037131237None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3610038131237None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3610039131237None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3610040131237None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3610041131237None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3610042131237None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3610043131237None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3610044131237None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3610045131237None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3610046131237None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3610047131237None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3610048131237None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3610049131237NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3610050131237NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3610051131237None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3610052131237None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3610053131237None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3610054131237Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3610055131237Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3610056131237Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3610057131237Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3610058131237None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3610059131237Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3610060131237None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3610061131237None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218282340000NoneNoneBuildingsKANPUR SH IN SHORAPUR TALUK OF YADGIR DISTRICT34741282.93
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3610062131238NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work100 Sqm486.93486.9317.49FalseNoneNoneFalseNoneFalse8516.40570
3610063131238NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum117.71117.71768.64FalseNoneNoneFalseNoneFalse90476.61440
3610064131238NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum126.38126.381311.57FalseNoneNoneFalseNoneFalse165756.21660
3610065131238NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum449.76449.76230.53FalseNoneNoneFalseNoneFalse103683.17280
3610066131238NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum167.27167.27225.13FalseNoneNoneFalseNoneFalse37657.49510
3610067131238NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3610068131238NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum329.57329.57807.35FalseNoneNoneFalseNoneFalse266078.33950
3610069131238NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum587.29587.29728.89FalseNoneNoneFalseNoneFalse428069.80810
3610070131238NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7420.377420.37161.37FalseNoneNoneFalseNoneFalse1197425.10690
3610071131238NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3610072131238NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3610073131238NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum14413.4114413.4155.14FalseNoneNoneFalseNoneFalse794755.42740
3610074131238NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3610075131238NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3610076131238NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workTonne110837.22110837.2250.82FalseNoneNoneFalseNoneFalse5632747.52040
3610077131238None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3610078131238NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3610079131238NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3610080131238NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1623.091623.091313.93FalseNoneNoneFalseNoneFalse2132626.64370
3610081131238NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3610082131238NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3610083131238NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3610084131238None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3610085131238None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3610086131238None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3610087131238None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3610088131238None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3610089131238None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3610090131238NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3610091131238None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3610092131238NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3610093131238NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3610094131238NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3610095131238NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3610096131238NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workm869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3610097131238NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3610098131238NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3610099131238NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3610100131238NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3610101131238NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3610102131238NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3610103131238None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3610104131238None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3610105131238NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3610106131238NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3610107131238NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3610108131238NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3610109131238NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3610110131238NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3610111131238NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3610112131238NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3610113131238NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3610114131238NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3610115131238NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3610116131238NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3610117131238NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3610118131238None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3610119131238NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3610120131238NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3610121131238None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3610122131238NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3610123131238None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.72102.35FalseNoneNoneFalseNoneFalse1301658.6420
3610124131238None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3610125131238None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3610126131238None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3610127131238None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3610128131238None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3610129131238None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3610130131238None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3610131131238None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3610132131238None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3610133131238None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3610134131238None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3610135131238None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3610136131238None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3610137131238None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3610138131238None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3610139131238None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3610140131238None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3610141131238None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3610142131238None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3610143131238None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3610144131238None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3610145131238None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3610146131238None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3610147131238None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3610148131238NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum130.1130.172.0FalseNoneNoneFalseNoneFalse9367.20
3610149131238NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3610150131238NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum6095.886095.8824.0FalseNoneNoneFalseNoneFalse146301.120
3610151131238NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum11107.6411107.6448.0FalseNoneNoneFalseNoneFalse533166.720
3610152131238NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3610153131238NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3610154131238NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3610155131238None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7702.867702.862.0FalseNoneNoneFalseNoneFalse15405.720
3610156131238None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum9156.769156.7610.8FalseNoneNoneFalseNoneFalse98893.0080
3610157131238None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm459.67459.67320.0FalseNoneNoneFalseNoneFalse147094.40
3610158131238None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm220.54220.54320.0FalseNoneNoneFalseNoneFalse70572.80
3610159131238None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3610160131238None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3610161131238NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3610162131238None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3610163131238None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3610164131238NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3610165131238NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3610166131238None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3610167131238None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3610168131238None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3610169131238NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3610170131238NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3610171131238NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3610172131238NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3610173131238NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3610174131238NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3610175131238NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3610176131238NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3610177131238None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3610178131238NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3610179131238NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3610180131238NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3610181131238NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3610182131238NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3610183131238NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3610184131238None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3610185131238NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3610186131238NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3610187131238None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3610188131238None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3610189131238None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3610190131238None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
3610191131238NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3610192131238NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3610193131238NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3610194131238NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3610195131238NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3610196131238NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3610197131238NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3610198131238NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3610199131238NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3610200131238NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3610201131238NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3610202131238NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3610203131238NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3610204131238NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3610205131238NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3610206131238NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3610207131238NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3610208131238NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3610209131238NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3610210131238NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3610211131238NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3610212131238NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3610213131238NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3610214131238NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3610215131238NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3610216131238NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3610217131238NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3610218131238NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3610219131238NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3610220131238NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3610221131238NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3610222131238Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3610223131238NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3610224131238NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workLtr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3610225131238NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3610226131238NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3610227131238NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3610228131238NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3610229131238NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3610230131238NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3610231131238NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3610232131238NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3610233131238NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3610234131238NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workUnit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3610235131238NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3610236131238NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3610237131238NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3610238131238None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3610239131238None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workUnit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3610240131238None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3610241131238None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3610242131238None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3610243131238NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3610244131238None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3610245131238NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3610246131238NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3610247131238NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3610248131238NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3610249131238NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3610250131238NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3610251131238NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3610252131238NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3610253131238NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3610254131238NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3610255131238None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3610256131238None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3610257131238NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3610258131238None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3610259131238None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3610260131238None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
3610261131238NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3610262131238NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3610263131238NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3610264131238NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3610265131238NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3610266131238NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3610267131238NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3610268131238NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3610269131238NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3610270131238NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3610271131238NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3610272131238NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3610273131238NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3610274131238NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3610275131238NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3610276131238NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3610277131238NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3610278131238NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3610279131238NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3610280131238NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3610281131238NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3610282131238NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3610283131238NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3610284131238NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3610285131238NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3610286131238NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3610287131238NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3610288131238NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3610289131238NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3610290131238NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3610291131238NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3610292131238NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3610293131238NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3610294131238NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3610295131238NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3610296131238NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3610297131238NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3610298131238NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3610299131238NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3610300131238NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3610301131238None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3610302131238None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3610303131238None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3610304131238None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3610305131238None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3610306131238NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3610307131238NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3610308131238NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3610309131238NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3610310131238NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3610311131238NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3610312131238NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3610313131238NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3610314131238NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3610315131238NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3610316131238NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3610317131238NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3610318131238NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3610319131238NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3610320131238NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3610321131238NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3610322131238None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3610323131238None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3610324131238None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3610325131238None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3610326131238None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3610327131238None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3610328131238None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3610329131238None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3610330131238None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3610331131238None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3610332131238None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3610333131238None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3610334131238None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3610335131238None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3610336131238None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3610337131238None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3610338131238None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3610339131238None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3610340131238None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3610341131238None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3610342131238None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3610343131238None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3610344131238None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3610345131238None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3610346131238None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3610347131238Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3610348131238None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3610349131238None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3610350131238None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3610351131238None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3610352131238None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3610353131238None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3610354131238NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3610355131238NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3610356131238NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3610357131238NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3610358131238NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3610359131238NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3610360131238NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3610361131238NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3610362131238NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3610363131238NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3610364131238NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3610365131238NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3610366131238None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3610367131238None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3610368131238None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3610369131238None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3610370131238None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3610371131238None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3610372131238None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3610373131238None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3610374131238None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3610375131238None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3610376131238None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3610377131238None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3610378131238None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3610379131238None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3610380131238None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3610381131238None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3610382131238None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3610383131238None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3610384131238None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3610385131238None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3610386131238None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3610387131238None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3610388131238None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3610389131238None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3610390131238None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3610391131238None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3610392131238None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3610393131238None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3610394131238None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3610395131238None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3610396131238None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3610397131238None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3610398131238None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3610399131238NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3610400131238NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3610401131238None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3610402131238None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3610403131238None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3610404131238Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3610405131238Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3610406131238Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3610407131238Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3610408131238None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3610409131238Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3610410131238None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3610411131238None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218282340000NoneNoneBuildingsTINTHANI IN SHORAPUR TALUK OF YADGIR DISTRICT34741282.93
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3610412131239NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work100 Sqm486.93486.9317.49FalseNoneNoneFalseNoneFalse8516.40570
3610413131239NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum117.71117.71768.64FalseNoneNoneFalseNoneFalse90476.61440
3610414131239NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum126.38126.381311.57FalseNoneNoneFalseNoneFalse165756.21660
3610415131239NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum449.76449.76230.53FalseNoneNoneFalseNoneFalse103683.17280
3610416131239NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum167.27167.27225.13FalseNoneNoneFalseNoneFalse37657.49510
3610417131239NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3610418131239NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum329.57329.57807.35FalseNoneNoneFalseNoneFalse266078.33950
3610419131239NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum587.29587.29728.89FalseNoneNoneFalseNoneFalse428069.80810
3610420131239NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7420.377420.37161.37FalseNoneNoneFalseNoneFalse1197425.10690
3610421131239NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3610422131239NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3610423131239NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum14413.4114413.4155.14FalseNoneNoneFalseNoneFalse794755.42740
3610424131239NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3610425131239NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3610426131239NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workTonne110837.22110837.2250.82FalseNoneNoneFalseNoneFalse5632747.52040
3610427131239None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3610428131239NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3610429131239NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3610430131239NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1623.091623.091313.93FalseNoneNoneFalseNoneFalse2132626.64370
3610431131239NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3610432131239NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3610433131239NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3610434131239None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3610435131239None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3610436131239None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3610437131239None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3610438131239None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3610439131239None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3610440131239NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3610441131239None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3610442131239NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3610443131239NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3610444131239NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3610445131239NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3610446131239NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workm869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3610447131239NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3610448131239NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3610449131239NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3610450131239NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3610451131239NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3610452131239NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3610453131239None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3610454131239None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3610455131239NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3610456131239NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3610457131239NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3610458131239NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3610459131239NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3610460131239NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3610461131239NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3610462131239NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3610463131239NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3610464131239NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3610465131239NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3610466131239NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3610467131239NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3610468131239None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3610469131239NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3610470131239NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3610471131239None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3610472131239NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3610473131239None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.72102.35FalseNoneNoneFalseNoneFalse1301658.6420
3610474131239None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3610475131239None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3610476131239None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3610477131239None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3610478131239None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3610479131239None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3610480131239None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3610481131239None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3610482131239None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3610483131239None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3610484131239None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3610485131239None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3610486131239None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3610487131239None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3610488131239None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3610489131239None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3610490131239None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3610491131239None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3610492131239None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3610493131239None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3610494131239None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3610495131239None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3610496131239None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3610497131239None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3610498131239NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum130.1130.172.0FalseNoneNoneFalseNoneFalse9367.20
3610499131239NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3610500131239NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum6095.886095.8824.0FalseNoneNoneFalseNoneFalse146301.120
3610501131239NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum11107.6411107.6448.0FalseNoneNoneFalseNoneFalse533166.720
3610502131239NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3610503131239NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3610504131239NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3610505131239None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7702.867702.862.0FalseNoneNoneFalseNoneFalse15405.720
3610506131239None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum9156.769156.7610.8FalseNoneNoneFalseNoneFalse98893.0080
3610507131239None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm459.67459.67320.0FalseNoneNoneFalseNoneFalse147094.40
3610508131239None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm220.54220.54320.0FalseNoneNoneFalseNoneFalse70572.80
3610509131239None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3610510131239None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3610511131239NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3610512131239None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3610513131239None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3610514131239NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3610515131239NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3610516131239None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3610517131239None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3610518131239None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3610519131239NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3610520131239NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3610521131239NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3610522131239NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3610523131239NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3610524131239NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3610525131239NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3610526131239NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3610527131239None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3610528131239NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3610529131239NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3610530131239NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3610531131239NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3610532131239NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3610533131239NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3610534131239None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3610535131239NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3610536131239NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3610537131239None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3610538131239None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3610539131239None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3610540131239None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
3610541131239NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3610542131239NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3610543131239NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3610544131239NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3610545131239NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3610546131239NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3610547131239NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3610548131239NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3610549131239NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3610550131239NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3610551131239NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3610552131239NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3610553131239NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3610554131239NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3610555131239NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3610556131239NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3610557131239NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3610558131239NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3610559131239NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3610560131239NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3610561131239NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3610562131239NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3610563131239NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3610564131239NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3610565131239NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3610566131239NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3610567131239NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3610568131239NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3610569131239NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3610570131239NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3610571131239NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3610572131239Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3610573131239NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3610574131239NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workLtr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3610575131239NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3610576131239NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3610577131239NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3610578131239NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3610579131239NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3610580131239NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3610581131239NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3610582131239NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3610583131239NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3610584131239NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workUnit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3610585131239NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3610586131239NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3610587131239NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3610588131239None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3610589131239None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workUnit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3610590131239None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3610591131239None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3610592131239None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3610593131239NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3610594131239None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3610595131239NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3610596131239NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3610597131239NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3610598131239NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3610599131239NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3610600131239NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3610601131239NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3610602131239NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3610603131239NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3610604131239NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3610605131239None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3610606131239None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3610607131239NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3610608131239None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3610609131239None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3610610131239None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
3610611131239NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3610612131239NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3610613131239NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3610614131239NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3610615131239NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3610616131239NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3610617131239NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3610618131239NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3610619131239NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3610620131239NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3610621131239NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3610622131239NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3610623131239NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3610624131239NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3610625131239NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3610626131239NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3610627131239NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3610628131239NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3610629131239NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3610630131239NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3610631131239NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3610632131239NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3610633131239NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3610634131239NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3610635131239NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3610636131239NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3610637131239NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3610638131239NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3610639131239NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3610640131239NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3610641131239NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3610642131239NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3610643131239NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3610644131239NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3610645131239NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3610646131239NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3610647131239NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3610648131239NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3610649131239NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3610650131239NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3610651131239None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3610652131239None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3610653131239None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3610654131239None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3610655131239None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3610656131239NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3610657131239NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3610658131239NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3610659131239NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3610660131239NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3610661131239NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3610662131239NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3610663131239NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3610664131239NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3610665131239NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3610666131239NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3610667131239NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3610668131239NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3610669131239NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3610670131239NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3610671131239NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3610672131239None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3610673131239None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3610674131239None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3610675131239None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3610676131239None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3610677131239None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3610678131239None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3610679131239None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3610680131239None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3610681131239None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3610682131239None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3610683131239None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3610684131239None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3610685131239None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3610686131239None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3610687131239None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3610688131239None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3610689131239None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3610690131239None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3610691131239None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3610692131239None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3610693131239None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3610694131239None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3610695131239None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3610696131239None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3610697131239Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3610698131239None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3610699131239None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3610700131239None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3610701131239None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3610702131239None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3610703131239None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3610704131239NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3610705131239NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3610706131239NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3610707131239NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3610708131239NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3610709131239NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3610710131239NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3610711131239NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3610712131239NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3610713131239NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3610714131239NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3610715131239NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3610716131239None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3610717131239None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3610718131239None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3610719131239None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3610720131239None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3610721131239None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3610722131239None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3610723131239None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3610724131239None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3610725131239None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3610726131239None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3610727131239None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3610728131239None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3610729131239None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3610730131239None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3610731131239None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3610732131239None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3610733131239None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3610734131239None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3610735131239None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3610736131239None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3610737131239None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3610738131239None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3610739131239None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3610740131239None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3610741131239None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3610742131239None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3610743131239None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3610744131239None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3610745131239None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3610746131239None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3610747131239None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3610748131239None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3610749131239NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3610750131239NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3610751131239None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3610752131239None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3610753131239None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3610754131239Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3610755131239Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3610756131239Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3610757131239Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3610758131239None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3610759131239Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3610760131239None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3610761131239None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218282340000NoneNoneBuildingsMUDNOOR IN SHORAPUR TALUK OF YADGIR DISTRICT (CIVIL WORKS)27736381.66
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3610762131240NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work100 Sqm486.93486.9317.09FalseNoneNoneFalseNoneFalse8321.63370
3610763131240NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum117.71117.71540.95FalseNoneNoneFalseNoneFalse63675.22450
3610764131240NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum126.38126.381430.43FalseNoneNoneFalseNoneFalse180777.74340
3610765131240NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum449.76449.76254.05FalseNoneNoneFalseNoneFalse114261.5280
3610766131240NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum167.27167.27218.94FalseNoneNoneFalseNoneFalse36622.09380
3610767131240NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3610768131240NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum329.57329.57901.41FalseNoneNoneFalseNoneFalse297077.69370
3610769131240NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum587.29587.29747.04FalseNoneNoneFalseNoneFalse438729.12160
3610770131240NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7420.377420.37155.33FalseNoneNoneFalseNoneFalse1152606.07210
3610771131240NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3610772131240NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3610773131240NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum14413.4114413.4157.58FalseNoneNoneFalseNoneFalse829924.14780
3610774131240NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3610775131240NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3610776131240NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workTonne110837.22110837.2250.59FalseNoneNoneFalseNoneFalse5607254.95980
3610777131240None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3610778131240NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3610779131240NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3610780131240NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1623.091623.091253.93FalseNoneNoneFalseNoneFalse2035241.24370
3610781131240NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3610782131240NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3610783131240NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3610784131240None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3610785131240None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3610786131240None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3610787131240None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3610788131240None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3610789131240None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3610790131240NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3610791131240None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3610792131240NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3610793131240NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3610794131240NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3610795131240NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3610796131240NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workm869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3610797131240NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3610798131240NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3610799131240NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3610800131240NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3610801131240NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3610802131240NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3610803131240None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3610804131240None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3610805131240NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3610806131240NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3610807131240NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3610808131240NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3610809131240NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3610810131240NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3610811131240NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3610812131240NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3610813131240NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3610814131240NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3610815131240NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3610816131240NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3610817131240NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3610818131240None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3610819131240NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3610820131240NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3610821131240None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3610822131240NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3610823131240None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.7294.35FalseNoneNoneFalseNoneFalse1199916.8820
3610824131240None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3610825131240None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3610826131240None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3610827131240None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3610828131240None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3610829131240None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3610830131240None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3610831131240None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3610832131240None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3610833131240None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3610834131240None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3610835131240None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3610836131240None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3610837131240None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3610838131240None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3610839131240None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3610840131240None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3610841131240None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3610842131240None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3610843131240None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3610844131240None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3610845131240None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3610846131240None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3610847131240None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3610848131240NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum130.1130.160.0FalseNoneNoneFalseNoneFalse7806.00
3610849131240NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum2922.82922.830.0FalseNoneNoneFalseNoneFalse87684.00
3610850131240NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum6095.886095.8820.0FalseNoneNoneFalseNoneFalse121917.60
3610851131240NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum11107.6411107.6440.0FalseNoneNoneFalseNoneFalse444305.60
3610852131240NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3610853131240NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3610854131240NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach296.12296.12100.0FalseNoneNoneFalseNoneFalse29612.00
3610855131240None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7702.867702.861.2FalseNoneNoneFalseNoneFalse9243.4320
3610856131240None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum9156.769156.766.48FalseNoneNoneFalseNoneFalse59335.80480
3610857131240None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm459.67459.67192.0FalseNoneNoneFalseNoneFalse88256.640
3610858131240None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm220.54220.54192.0FalseNoneNoneFalseNoneFalse42343.680
3610859131240None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3610860131240None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3610861131240NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3610862131240None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3610863131240None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3610864131240NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3610865131240NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3610866131240None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3610867131240None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3610868131240None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3610869131240NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3610870131240NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3610871131240NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3610872131240NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3610873131240NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3610874131240NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3610875131240NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3610876131240NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3610877131240None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3610878131240NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3610879131240NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3610880131240NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3610881131240NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3610882131240NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3610883131240NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3610884131240None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3610885131240NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3610886131240NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3610887131240None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3610888131240None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3610889131240None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3610890131240None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
3610891131240None1.23Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum3323.03323.0164.36FalseNoneNoneFalseNoneFalse546168.280
17218282340000NoneNoneBuildingsMUDNOOR IN SHORAPUR TALUK OF YADGIR DISTRICT (WATER SUPPLY AND SANITARY WORKS)2711710.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3610892131241NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3610893131241NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3610894131241NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3610895131241NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3610896131241NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3610897131241NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3610898131241NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3610899131241NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3610900131241NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3610901131241NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3610902131241NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3610903131241NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3610904131241NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3610905131241NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3610906131241NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3610907131241NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3610908131241NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3610909131241NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3610910131241NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3610911131241NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3610912131241NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3610913131241NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3610914131241NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3610915131241NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3610916131241NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3610917131241NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3610918131241NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3610919131241NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3610920131241NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3610921131241NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3610922131241NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3610923131241Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3610924131241NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3610925131241NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workLtr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3610926131241NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3610927131241NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3610928131241NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3610929131241NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3610930131241NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3610931131241NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3610932131241NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3610933131241NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3610934131241NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3610935131241NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workUnit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3610936131241NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3610937131241NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3610938131241NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3610939131241None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3610940131241None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workUnit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3610941131241None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3610942131241None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3610943131241None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3610944131241NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3610945131241None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3610946131241NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3610947131241NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3610948131241NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3610949131241NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3610950131241NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3610951131241NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3610952131241NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3610953131241NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3610954131241NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3610955131241NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3610956131241None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3610957131241None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3610958131241NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3610959131241None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3610960131241None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3610961131241None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
17218282340000NoneNoneBuildingsMUDNOOR IN SHORAPUR TALUK OF YADGIR DISTRICT (ELECTRICAL WORKS)4364380.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3610962131242NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3610963131242NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3610964131242NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3610965131242NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3610966131242NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3610967131242NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3610968131242NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3610969131242NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3610970131242NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3610971131242NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3610972131242NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3610973131242NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3610974131242NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3610975131242NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3610976131242NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3610977131242NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3610978131242NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3610979131242NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3610980131242NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3610981131242NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3610982131242NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3610983131242NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3610984131242NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3610985131242NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3610986131242NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3610987131242NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3610988131242NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3610989131242NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3610990131242NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3610991131242NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3610992131242NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3610993131242NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3610994131242NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3610995131242NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3610996131242NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3610997131242NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3610998131242NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3610999131242NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3611000131242NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3611001131242NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3611002131242None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3611003131242None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3611004131242None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3611005131242None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3611006131242None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3611007131242NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3611008131242NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3611009131242NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3611010131242NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3611011131242NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3611012131242NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3611013131242NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3611014131242NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3611015131242NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3611016131242NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3611017131242NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3611018131242NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3611019131242NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3611020131242NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3611021131242NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3611022131242NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3611023131242None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3611024131242None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3611025131242None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3611026131242None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3611027131242None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3611028131242None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3611029131242None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3611030131242None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3611031131242None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3611032131242None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3611033131242None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3611034131242None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3611035131242None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3611036131242None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3611037131242None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3611038131242None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3611039131242None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3611040131242None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3611041131242None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3611042131242None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3611043131242None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3611044131242None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3611045131242None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3611046131242None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3611047131242None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3611048131242Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3611049131242None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3611050131242None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3611051131242None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3611052131242None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3611053131242None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3611054131242None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3611055131242NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3611056131242NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3611057131242NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3611058131242NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3611059131242NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3611060131242NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3611061131242NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3611062131242NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3611063131242NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3611064131242NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3611065131242NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3611066131242NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3611067131242None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3611068131242None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3611069131242None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3611070131242None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3611071131242None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3611072131242None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3611073131242None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3611074131242None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3611075131242None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3611076131242None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3611077131242None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3611078131242None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3611079131242None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3611080131242None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3611081131242None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3611082131242None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3611083131242None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3611084131242None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3611085131242None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3611086131242None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3611087131242None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3611088131242None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3611089131242None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3611090131242None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3611091131242None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3611092131242None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3611093131242None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3611094131242None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3611095131242None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3611096131242None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3611097131242None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3611098131242None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3611099131242None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3611100131242NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3611101131242NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3611102131242None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3611103131242None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3611104131242None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3611105131242Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3611106131242Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3611107131242Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3611108131242Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3611109131242None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3611110131242Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3611111131242None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3611112131242None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218282340000NoneNoneBuildingsHEGGANDODDI IN SHORAPUR TALUK OF YADGIR DISTRICT34812473.11
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3611113131243NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work100 Sqm486.93486.9317.09FalseNoneNoneFalseNoneFalse8321.63370
3611114131243NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum117.71117.71540.95FalseNoneNoneFalseNoneFalse63675.22450
3611115131243NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum126.38126.381430.43FalseNoneNoneFalseNoneFalse180777.74340
3611116131243NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum449.76449.76254.05FalseNoneNoneFalseNoneFalse114261.5280
3611117131243NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum167.27167.27218.94FalseNoneNoneFalseNoneFalse36622.09380
3611118131243NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3611119131243NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum329.57329.57901.41FalseNoneNoneFalseNoneFalse297077.69370
3611120131243NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum587.29587.29747.04FalseNoneNoneFalseNoneFalse438729.12160
3611121131243NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7420.377420.37155.33FalseNoneNoneFalseNoneFalse1152606.07210
3611122131243NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3611123131243NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3611124131243NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum14413.4114413.4157.58FalseNoneNoneFalseNoneFalse829924.14780
3611125131243NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3611126131243NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3611127131243NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workTonne110837.22110837.2250.59FalseNoneNoneFalseNoneFalse5607254.95980
3611128131243None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3611129131243NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3611130131243NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3611131131243NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1623.091623.091253.93FalseNoneNoneFalseNoneFalse2035241.24370
3611132131243NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3611133131243NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3611134131243NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3611135131243None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3611136131243None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3611137131243None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3611138131243None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3611139131243None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3611140131243None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3611141131243NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3611142131243None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3611143131243NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3611144131243NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3611145131243NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3611146131243NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3611147131243NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workm869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3611148131243NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3611149131243NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3611150131243NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3611151131243NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3611152131243NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3611153131243NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3611154131243None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3611155131243None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3611156131243NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3611157131243NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3611158131243NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3611159131243NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3611160131243NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3611161131243NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3611162131243NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3611163131243NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3611164131243NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3611165131243NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3611166131243NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3611167131243NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3611168131243NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3611169131243None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3611170131243NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3611171131243NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3611172131243None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3611173131243NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3611174131243None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.7294.35FalseNoneNoneFalseNoneFalse1199916.8820
3611175131243None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3611176131243None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3611177131243None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3611178131243None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3611179131243None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3611180131243None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3611181131243None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3611182131243None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3611183131243None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3611184131243None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3611185131243None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3611186131243None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3611187131243None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3611188131243None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3611189131243None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3611190131243None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3611191131243None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3611192131243None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3611193131243None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3611194131243None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3611195131243None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3611196131243None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3611197131243None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3611198131243None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3611199131243NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum130.1130.160.0FalseNoneNoneFalseNoneFalse7806.00
3611200131243NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum2922.82922.830.0FalseNoneNoneFalseNoneFalse87684.00
3611201131243NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum6095.886095.8820.0FalseNoneNoneFalseNoneFalse121917.60
3611202131243NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum11107.6411107.6440.0FalseNoneNoneFalseNoneFalse444305.60
3611203131243NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3611204131243NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3611205131243NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach296.12296.12100.0FalseNoneNoneFalseNoneFalse29612.00
3611206131243None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7702.867702.861.2FalseNoneNoneFalseNoneFalse9243.4320
3611207131243None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum9156.769156.766.48FalseNoneNoneFalseNoneFalse59335.80480
3611208131243None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm459.67459.67192.0FalseNoneNoneFalseNoneFalse88256.640
3611209131243None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm220.54220.54192.0FalseNoneNoneFalseNoneFalse42343.680
3611210131243None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3611211131243None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3611212131243NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3611213131243None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3611214131243None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3611215131243NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3611216131243NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3611217131243None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3611218131243None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3611219131243None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3611220131243NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3611221131243NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3611222131243NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3611223131243NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3611224131243NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3611225131243NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3611226131243NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3611227131243NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3611228131243None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3611229131243NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3611230131243NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3611231131243NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3611232131243NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3611233131243NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3611234131243NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3611235131243None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3611236131243NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3611237131243NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3611238131243None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3611239131243None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3611240131243None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3611241131243None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
3611242131243None1.23Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum3323.03323.0164.36FalseNoneNoneFalseNoneFalse546168.280
3611243131243NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3611244131243NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3611245131243NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3611246131243NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3611247131243NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3611248131243NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3611249131243NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3611250131243NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3611251131243NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3611252131243NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3611253131243NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3611254131243NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3611255131243NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3611256131243NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3611257131243NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3611258131243NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3611259131243NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3611260131243NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3611261131243NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3611262131243NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3611263131243NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3611264131243NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3611265131243NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3611266131243NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3611267131243NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3611268131243NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3611269131243NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3611270131243NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3611271131243NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3611272131243NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3611273131243NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3611274131243Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3611275131243NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3611276131243NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workLtr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3611277131243NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3611278131243NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3611279131243NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3611280131243NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3611281131243NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3611282131243NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3611283131243NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3611284131243NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3611285131243NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3611286131243NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workUnit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3611287131243NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3611288131243NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3611289131243NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3611290131243None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3611291131243None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workUnit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3611292131243None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3611293131243None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3611294131243None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3611295131243NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3611296131243None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3611297131243NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3611298131243NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3611299131243NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3611300131243NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3611301131243NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3611302131243NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3611303131243NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3611304131243NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3611305131243NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3611306131243NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3611307131243None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3611308131243None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3611309131243NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3611310131243None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3611311131243None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3611312131243None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
3611313131243NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3611314131243NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3611315131243NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3611316131243NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3611317131243NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3611318131243NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3611319131243NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3611320131243NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3611321131243NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3611322131243NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3611323131243NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3611324131243NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3611325131243NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3611326131243NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3611327131243NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3611328131243NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3611329131243NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3611330131243NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3611331131243NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3611332131243NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3611333131243NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3611334131243NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3611335131243NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3611336131243NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3611337131243NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3611338131243NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3611339131243NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3611340131243NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3611341131243NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3611342131243NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3611343131243NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3611344131243NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3611345131243NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3611346131243NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3611347131243NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3611348131243NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3611349131243NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3611350131243NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3611351131243NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3611352131243NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3611353131243None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3611354131243None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3611355131243None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3611356131243None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3611357131243None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3611358131243NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3611359131243NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3611360131243NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3611361131243NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3611362131243NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3611363131243NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3611364131243NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3611365131243NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3611366131243NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3611367131243NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3611368131243NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3611369131243NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3611370131243NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3611371131243NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3611372131243NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3611373131243NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3611374131243None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3611375131243None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3611376131243None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3611377131243None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3611378131243None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3611379131243None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3611380131243None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3611381131243None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3611382131243None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3611383131243None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3611384131243None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3611385131243None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3611386131243None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3611387131243None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3611388131243None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3611389131243None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3611390131243None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3611391131243None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3611392131243None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3611393131243None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3611394131243None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3611395131243None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3611396131243None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3611397131243None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3611398131243None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3611399131243Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3611400131243None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3611401131243None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3611402131243None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3611403131243None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3611404131243None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3611405131243None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3611406131243NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3611407131243NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3611408131243NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3611409131243NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3611410131243NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3611411131243NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3611412131243NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3611413131243NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3611414131243NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3611415131243NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3611416131243NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3611417131243NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3611418131243None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3611419131243None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3611420131243None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3611421131243None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3611422131243None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3611423131243None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3611424131243None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3611425131243None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3611426131243None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3611427131243None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3611428131243None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3611429131243None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3611430131243None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3611431131243None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3611432131243None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3611433131243None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3611434131243None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3611435131243None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3611436131243None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3611437131243None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3611438131243None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3611439131243None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3611440131243None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3611441131243None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3611442131243None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3611443131243None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3611444131243None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3611445131243None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3611446131243None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3611447131243None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3611448131243None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3611449131243None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3611450131243None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3611451131243NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3611452131243NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3611453131243None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3611454131243None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3611455131243None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3611456131243Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3611457131243Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3611458131243Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3611459131243Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3611460131243None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3611461131243Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3611462131243None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3611463131243None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
17218282340000NoneNoneBuildingsNARAYANPUR IN SHORAPUR TALUK OF YADGIR DISTRICT (CIVIL WORKS)27725914.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3611464131244NoneCSR:V-3 PAGE NO 9 Itm 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work100 Sqm486.93486.9317.49FalseNoneNoneFalseNoneFalse8516.40570
3611465131244NoneV-1 page 8 itm 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum117.71117.71768.64FalseNoneNoneFalseNoneFalse90476.61440
3611466131244NoneV-1page 8 itm 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum126.38126.38809.88FalseNoneNoneFalseNoneFalse102352.63440
3611467131244NoneV-1page 8 itm 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum449.76449.76583.66FalseNoneNoneFalseNoneFalse262506.92160
3611468131244NoneV-3page 3 ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum167.27167.27225.13FalseNoneNoneFalseNoneFalse37657.49510
3611469131244NoneV-2page5 itm 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm146.2146.2774.16FalseNoneNoneFalseNoneFalse113182.1920
3611470131244NoneV-1pg7 itm1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum329.57329.57305.66FalseNoneNoneFalseNoneFalse100736.36620
3611471131244NoneV-1page7vitm1.8Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum587.29587.291082.02FalseNoneNoneFalseNoneFalse635459.52580
3611472131244NoneV-1page 15 itm2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7420.377420.37161.37FalseNoneNoneFalseNoneFalse1197425.10690
3611473131244NoneV-1page15 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8478.338478.33177.95FalseNoneNoneFalseNoneFalse1508718.82350
3611474131244NoneV-1page16 itm 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8635.338635.3313.4FalseNoneNoneFalseNoneFalse115713.4220
3611475131244NoneV-1page15itm 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum14413.4114413.4152.43FalseNoneNoneFalseNoneFalse755695.08630
3611476131244NoneV-3page135itm15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo252.76252.7613.0FalseNoneNoneFalseNoneFalse3285.880
3611477131244NoneV-2page55 itm 8.16.aProviding Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1533.881533.8813.81FalseNoneNoneFalseNoneFalse21182.88280
3611478131244NoneV-1page18itm2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workTonne110837.22110837.2250.48FalseNoneNoneFalseNoneFalse5595062.86560
3611479131244None18-19SR ITM4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr38.9438.94145.02FalseNoneNoneFalseNoneFalse5647.07880
3611480131244NoneDATA RATEProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr86.1486.14145.02FalseNoneNoneFalseNoneFalse12492.02280
3611481131244NoneV-2PAGE 9 ITM5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7915.977915.978.76FalseNoneNoneFalseNoneFalse69343.89720
3611482131244NoneV-2PAGE 14 ITM 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1623.091623.091313.93FalseNoneNoneFalseNoneFalse2132626.64370
3611483131244NoneV-2page 14 itm 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1367.861367.86171.24FalseNoneNoneFalseNoneFalse234232.34640
3611484131244NoneV-2 page100 itm 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum122431.79122431.791.2FalseNoneNoneFalseNoneFalse146918.1480
3611485131244NoneV-2 page 105 itm 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1258.821258.8232.0FalseNoneNoneFalseNoneFalse40282.240
3611486131244None22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos681.45681.4564.0FalseNoneNoneFalseNoneFalse43612.80
3611487131244None22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos464.63464.6332.0FalseNoneNoneFalseNoneFalse14868.160
3611488131244None22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos185.85185.8564.0FalseNoneNoneFalseNoneFalse11894.40
3611489131244None22.15.9PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos86.7386.73128.0FalseNoneNoneFalseNoneFalse11101.440
3611490131244None22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos123.9123.932.0FalseNoneNoneFalseNoneFalse3964.80
3611491131244None12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1303.431303.4332.0FalseNoneNoneFalseNoneFalse41709.760
3611492131244NoneV-2page69 itm 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos74.3474.34192.0FalseNoneNoneFalseNoneFalse14273.280
3611493131244None20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr64.4364.43168.45FalseNoneNoneFalseNoneFalse10853.23350
3611494131244NoneV-2page105 itm 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4115.964115.9674.84FalseNoneNoneFalseNoneFalse308038.44640
3611495131244NoneV-2page109 itm 12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm8343.438343.4369.39FalseNoneNoneFalseNoneFalse578950.60770
3611496131244NoneV-2page109 itm 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm7085.847085.846.84FalseNoneNoneFalseNoneFalse48467.14560
3611497131244NoneV-2page 86itm11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg208.15208.151600.83FalseNoneNoneFalseNoneFalse333212.76450
3611498131244NoneV-2page 111itm 12.93.1Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workm869.78869.7864.35FalseNoneNoneFalseNoneFalse55970.3430
3611499131244NoneV-2page84 itm 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKgs168.5168.51724.91FalseNoneNoneFalseNoneFalse290647.3350
3611500131244NoneV-2page 41itm 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm386.57386.571763.82FalseNoneNoneFalseNoneFalse681839.89740
3611501131244NoneV-2page 43 itm 8.10Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm261.43261.431176.83FalseNoneNoneFalseNoneFalse307658.66690
3611502131244NoneV-2page50 itm 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm123.9123.92919.03FalseNoneNoneFalseNoneFalse361667.8170
3611503131244NoneV-2page42itm 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm432.41432.41975.48FalseNoneNoneFalseNoneFalse421807.30680
3611504131244NoneV-2page41 itm 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm438.61438.61163.05FalseNoneNoneFalseNoneFalse71515.36050
3611505131244None8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr47.0847.082013.85FalseNoneNoneFalseNoneFalse94812.0580
3611506131244None10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm254.88254.8813.0FalseNoneNoneFalseNoneFalse3313.440
3611507131244NoneV-2page 54itm 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr64.4364.43628.05FalseNoneNoneFalseNoneFalse40465.26150
3611508131244NoneV-2page61itm 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1455.831455.83580.89FalseNoneNoneFalseNoneFalse845677.08870
3611509131244NoneV-2page59 itm9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm991.2991.271.5FalseNoneNoneFalseNoneFalse70870.80
3611510131244NoneV-2page63 itm 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3199.13199.134.54FalseNoneNoneFalseNoneFalse110496.9140
3611511131244NoneV-2page 4 itm 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm365.51365.51316.07FalseNoneNoneFalseNoneFalse115526.74570
3611512131244NoneV-2page 60 itm 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1101.471101.4759.14FalseNoneNoneFalseNoneFalse65140.93580
3611513131244NoneV-2page65 itmv9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1795.311795.31259.57FalseNoneNoneFalseNoneFalse466008.61670
3611514131244NoneV-2 page85 itm11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg700.04700.04357.82FalseNoneNoneFalseNoneFalse250488.31280
3611515131244NoneV-2 page 48itm 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm157.35157.352741.14FalseNoneNoneFalseNoneFalse431318.3790
3611516131244NoneV-2page 46itm8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm193.28193.28759.66FalseNoneNoneFalseNoneFalse146827.08480
3611517131244NoneV-2page47 itm8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm61.9561.9596.21FalseNoneNoneFalseNoneFalse5960.20950
3611518131244NoneV-2page48 itm 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm142.49142.4976.23FalseNoneNoneFalseNoneFalse10862.01270
3611519131244NoneV-2page47itm 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm65.6765.67179.6FalseNoneNoneFalseNoneFalse11794.3320
3611520131244None8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm838.8838.8179.6FalseNoneNoneFalseNoneFalse150648.480
3611521131244NoneV-2page64itm 9.36Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm2044.352044.3517.32FalseNoneNoneFalseNoneFalse35408.1420
3611522131244NoneV-2page77 itm 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm5548.245548.245.25FalseNoneNoneFalseNoneFalse29128.260
3611523131244None15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1443.441443.44726.5FalseNoneNoneFalseNoneFalse1048659.160
3611524131244NoneV-2PAGE22 ITM 7.17Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm411.35411.3524.74FalseNoneNoneFalseNoneFalse10176.7990
3611525131244None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.72102.35FalseNoneNoneFalseNoneFalse1301658.6420
3611526131244None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum13565.5613565.5651.01FalseNoneNoneFalseNoneFalse691979.21560
3611527131244None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.72115.4FalseNoneNoneFalseNoneFalse1467624.8880
3611528131244None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum12717.7212717.727.07FalseNoneNoneFalseNoneFalse89914.28040
3611529131244None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum13565.5613565.5612.12FalseNoneNoneFalseNoneFalse164414.58720
3611530131244None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum11911.1311911.1314.18FalseNoneNoneFalseNoneFalse168899.82340
3611531131244None12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4317.924317.9220.48FalseNoneNoneFalseNoneFalse88431.00160
3611532131244None12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo141.25141.2536.0FalseNoneNoneFalseNoneFalse5085.00
3611533131244None9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1642.911642.9156.5FalseNoneNoneFalseNoneFalse92824.4150
3611534131244None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm6601.396601.3930.54FalseNoneNoneFalseNoneFalse201606.45060
3611535131244None10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4877.944877.949.69FalseNoneNoneFalseNoneFalse47267.23860
3611536131244None15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm761.99761.9992.01FalseNoneNoneFalseNoneFalse70110.69990
3611537131244None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm350.64350.64215.82FalseNoneNoneFalseNoneFalse75675.12480
3611538131244None13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr360.55360.5568.92FalseNoneNoneFalseNoneFalse24849.1060
3611539131244None9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3533.633533.6311.09FalseNoneNoneFalseNoneFalse39187.95670
3611540131244None9.30Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm6601.396601.3913.73FalseNoneNoneFalseNoneFalse90637.08470
3611541131244None10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm4963.434963.433.81FalseNoneNoneFalseNoneFalse18910.66830
3611542131244None1.4.1 V-1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.84299.8411.06FalseNoneNoneFalseNoneFalse3316.23040
3611543131244None1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum320.9320.91.7FalseNoneNoneFalseNoneFalse545.530
3611544131244None17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1391.41391.47.0FalseNoneNoneFalseNoneFalse9739.80
3611545131244None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1241.481241.480.28FalseNoneNoneFalseNoneFalse347.61440
3611546131244None17.2 V-2 Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1469.451469.450.14FalseNoneNoneFalseNoneFalse205.7230
3611547131244None17. V-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1476.891476.890.14FalseNoneNoneFalseNoneFalse206.76460
3611548131244None17.4 V-2Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum1659.021659.020.14FalseNoneNoneFalseNoneFalse232.26280
3611549131244None17.14 V-2Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1449.631449.631.0FalseNoneNoneFalseNoneFalse1449.630
3611550131244NoneV3 305.3.4Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum130.1130.172.0FalseNoneNoneFalseNoneFalse9367.20
3611551131244NoneV-3 4.2Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum2922.82922.836.0FalseNoneNoneFalseNoneFalse105220.80
3611552131244NoneV3 6.1 ISSUE RATEConstruction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum6095.886095.8824.0FalseNoneNoneFalseNoneFalse146301.120
3611553131244NoneV-3 6.2 ISSUE RATEConstruction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum11107.6411107.6448.0FalseNoneNoneFalseNoneFalse533166.720
3611554131244NoneV-3 8.10 Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm105.32105.3215.0FalseNoneNoneFalseNoneFalse1579.80
3611555131244NoneV-3Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm87.9787.97448.0FalseNoneNoneFalseNoneFalse39410.560
3611556131244NoneV-314621ASupplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm Kerb Stone ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach296.12296.12150.0FalseNoneNoneFalseNoneFalse44418.00
3611557131244None2.1.4 V-1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7702.867702.862.0FalseNoneNoneFalseNoneFalse15405.720
3611558131244None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum9156.769156.7610.8FalseNoneNoneFalseNoneFalse98893.0080
3611559131244None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm459.67459.67320.0FalseNoneNoneFalseNoneFalse147094.40
3611560131244None8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm220.54220.54320.0FalseNoneNoneFalseNoneFalse70572.80
3611561131244None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8761.098761.099.36FalseNoneNoneFalseNoneFalse82003.80240
3611562131244None8.20 V-3Providing and fixing 1.8 m high GI barbed wire fencing with 2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm672.78672.78390.0FalseNoneNoneFalseNoneFalse262384.20
3611563131244NoneV1 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum526.58526.5822.51FalseNoneNoneFalseNoneFalse11853.31580
3611564131244None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum8732.838732.834.32FalseNoneNoneFalseNoneFalse37725.82560
3611565131244None2.5.2 V1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum9326.329326.325.89FalseNoneNoneFalseNoneFalse54932.02480
3611566131244NoneV2 15.14UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm2072.852072.8536.6FalseNoneNoneFalseNoneFalse75866.310
3611567131244NoneV5 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2430.922430.928.0FalseNoneNoneFalseNoneFalse19447.360
3611568131244None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum14413.4114413.419.87FalseNoneNoneFalseNoneFalse142260.35670
3611569131244None15.5 V-2Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm749.6749.663.57FalseNoneNoneFalseNoneFalse47652.0720
3611570131244None8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm110.27110.2720.1FalseNoneNoneFalseNoneFalse2216.4270
3611571131244NoneV-5P140I12.4Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach6551.836551.831.0FalseNoneNoneFalseNoneFalse6551.830
3611572131244NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3611573131244NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above 50 Mtrs and upto 100 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3611574131244NoneV-5P139I12.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth" Above100 Mtrs. and upto 150 Mtr ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3611575131244NoneV-5P143I12.32Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr2394.992394.9920.0FalseNoneNoneFalseNoneFalse47899.80
3611576131244NoneV-5P155I13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr681.45681.45150.0FalseNoneNoneFalseNoneFalse102217.50
3611577131244NoneV-5P143I12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos185.85185.851.0FalseNoneNoneFalseNoneFalse185.850
3611578131244NoneV-5P154I12.34Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3611579131244None18-19 SR13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos260.19260.191.0FalseNoneNoneFalseNoneFalse260.190
3611580131244NoneV-5P154I13.11.5Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. 5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach39817.7439817.741.0FalseNoneNoneFalseNoneFalse39817.740
3611581131244NoneV-5P155I13.23Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach11832.4511832.451.0FalseNoneNoneFalseNoneFalse11832.450
3611582131244NoneV-5P155I13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet1920.451920.451.0FalseNoneNoneFalseNoneFalse1920.450
3611583131244NoneV-5P155I13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob49.5649.56100.0FalseNoneNoneFalseNoneFalse4956.00
3611584131244NoneV-5P156I13.32Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob8053.58053.51.0FalseNoneNoneFalseNoneFalse8053.50
3611585131244NoneV-5P156I13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob1672.651672.651.0FalseNoneNoneFalseNoneFalse1672.650
3611586131244None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr208.15208.15165.0FalseNoneNoneFalseNoneFalse34344.750
3611587131244NoneV-5P20I5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete 16 SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.5330000.0FalseNoneNoneFalseNoneFalse15900.00
3611588131244NoneV-5P21I5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach17990.2817990.281.0FalseNoneNoneFalseNoneFalse17990.280
3611589131244None5.6.6 V-6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach404.08404.081.0FalseNoneNoneFalseNoneFalse404.080
3611590131244None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach514.19514.191.0FalseNoneNoneFalseNoneFalse514.190
3611591131244None13.18.1Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach344.44344.441.0FalseNoneNoneFalseNoneFalse344.440
3611592131244None5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKvar594.72594.721.0FalseNoneNoneFalseNoneFalse594.720
17218282340000NoneNoneBuildingsNARAYANPUR IN SHORAPUR TALUK OF YADGIR DISTRICT (WATER SUPPLY AND SANITARY WORKS)2711710.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3611593131245NoneV-2 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr376.66376.6650.0FalseNoneNoneFalseNoneFalse18833.00
3611594131245NoneV-2 13.50.6Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
3611595131245NoneV-2 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr358.07358.07185.0FalseNoneNoneFalseNoneFalse66242.950
3611596131245NoneV-2 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr477.02477.02120.0FalseNoneNoneFalseNoneFalse57242.40
3611597131245NoneV-2 IT.NO 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr244.08244.0835.0FalseNoneNoneFalseNoneFalse8542.80
3611598131245NoneV-2 IT.NO 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr360.55360.5550.0FalseNoneNoneFalseNoneFalse18027.50
3611599131245NoneV-2 P.NO 128 IT.NO 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo302.32302.3255.0FalseNoneNoneFalseNoneFalse16627.60
3611600131245NoneV-2 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1511.581511.5821.0FalseNoneNoneFalseNoneFalse31743.180
3611601131245NoneV-2 P.NO 127 IT.NO 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6891.326891.324.0FalseNoneNoneFalseNoneFalse27565.280
3611602131245NoneV-2 P.NO 130 IT.NO 14.40.2600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo614.54614.544.0FalseNoneNoneFalseNoneFalse2458.160
3611603131245NoneV-2 P.NO 123 IT.NO 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo179.66179.664.0FalseNoneNoneFalseNoneFalse718.640
3611604131245NoneV-2 P.NO 178 IT.NO 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo7405.57405.59.0FalseNoneNoneFalseNoneFalse66649.50
3611605131245NoneV-2 P.NO 124 IT.NO14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6051.286051.2810.0FalseNoneNoneFalseNoneFalse60512.80
3611606131245NoneV-2 P.NO 126 IT.NO 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6296.66296.62.0FalseNoneNoneFalseNoneFalse12593.20
3611607131245NoneV-2 P.NO 126 IT.NO 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm)" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6960.76960.74.0FalseNoneNoneFalseNoneFalse27842.80
3611608131245NoneV-2 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo898.28898.2812.0FalseNoneNoneFalseNoneFalse10779.360
3611609131245NoneV-2 P.NO 124 IT.NO 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3818.63818.613.0FalseNoneNoneFalseNoneFalse49641.80
3611610131245NoneV-2 P.NO 120 IT.NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr382.85382.8590.0FalseNoneNoneFalseNoneFalse34456.50
3611611131245NoneV-2 P.NO 120 IT.NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr469.58469.5870.0FalseNoneNoneFalseNoneFalse32870.60
3611612131245NoneV-2 p.NO 120 IT.NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.070.0FalseNoneNoneFalseNoneFalse41370.00
3611613131245NoneV-2 P.NO 120 IT.NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr690.12690.1230.0FalseNoneNoneFalseNoneFalse20703.60
3611614131245NoneV-2 P.NO 120 IT.NO 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr664.1664.120.0FalseNoneNoneFalseNoneFalse13282.00
3611615131245NoneV-2 P.NO 120IT.NO 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc." 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr967.66967.6620.0FalseNoneNoneFalseNoneFalse19353.20
3611616131245NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 20mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr268.86268.8650.0FalseNoneNoneFalseNoneFalse13443.00
3611617131245NoneV-2 P.NO 120 IT.NO 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 25mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr366.74366.7450.0FalseNoneNoneFalseNoneFalse18337.00
3611618131245NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.0215.0FalseNoneNoneFalseNoneFalse127065.00
3611619131245NoneV-2 P.NO 120 IT.NO 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 65mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr1734.61734.625.0FalseNoneNoneFalseNoneFalse43365.00
3611620131245NoneV-2 P.NO 120 IT.NO 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) 50mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr893.32893.3240.0FalseNoneNoneFalseNoneFalse35732.80
3611621131245NoneV2 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :" 25 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach411.35411.3512.0FalseNoneNoneFalseNoneFalse4936.20
3611622131245NoneV2-13.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach740.92740.927.0FalseNoneNoneFalseNoneFalse5186.440
3611623131245NoneV-2 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach869.78869.789.0FalseNoneNoneFalseNoneFalse7828.020
3611624131245Nonev2-13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3611625131245NoneV-2,A-13, IT.NO 13.2.1Brass bib-cock 15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo354.35354.3519.0FalseNoneNoneFalseNoneFalse6732.650
3611626131245NoneV-2 IT.NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workLtr11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3611627131245NoneV2 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg182.13182.13125.0FalseNoneNoneFalseNoneFalse22766.250
3611628131245NoneMarket RateProviding and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo177.0177.055.0FalseNoneNoneFalseNoneFalse9735.00
3611629131245NoneMarket RateAir Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo413.0413.012.0FalseNoneNoneFalseNoneFalse4956.00
3611630131245NoneMarket RateAir Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo590.0590.012.0FalseNoneNoneFalseNoneFalse7080.00
3611631131245NoneMarket RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6844.06844.09.0FalseNoneNoneFalseNoneFalse61596.00
3611632131245NoneMarket RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3611633131245NoneMarket RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo767.0767.095.0FalseNoneNoneFalseNoneFalse72865.00
3611634131245NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. a) 65mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4130.04130.02.0FalseNoneNoneFalseNoneFalse8260.00
3611635131245NoneMarket RateSupplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required. b) 50mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3304.03304.04.0FalseNoneNoneFalseNoneFalse13216.00
3611636131245NoneV2 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workUnit345.68345.684.0FalseNoneNoneFalseNoneFalse1382.720
3611637131245NoneV2 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm5335.135335.1318.0FalseNoneNoneFalseNoneFalse96032.340
3611638131245NoneV2 10.8Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm3455.573455.5710.0FalseNoneNoneFalseNoneFalse34555.70
3611639131245NoneV2 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo79.379.370.0FalseNoneNoneFalseNoneFalse5551.00
3611640131245None14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach111.51111.5123.0FalseNoneNoneFalseNoneFalse2564.730
3611641131245None14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workUnit379.13379.1323.0FalseNoneNoneFalseNoneFalse8719.990
3611642131245None13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach102.84102.8423.0FalseNoneNoneFalseNoneFalse2365.320
3611643131245None14.22.AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1003.591003.5923.0FalseNoneNoneFalseNoneFalse23082.570
3611644131245None13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo768.18768.1853.0FalseNoneNoneFalseNoneFalse40713.540
3611645131245NoneV2 14.63AProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4667.314667.314.0FalseNoneNoneFalseNoneFalse18669.240
3611646131245None14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo5518.515518.514.0FalseNoneNoneFalseNoneFalse22074.040
3611647131245NoneELE 7.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo39372.9439372.943.0FalseNoneNoneFalseNoneFalse118118.820
3611648131245NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-110mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo944.0944.010.0FalseNoneNoneFalseNoneFalse9440.00
3611649131245NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-75mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3611650131245NoneA.RDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes. Core cut-160MM dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1298.01298.01.0FalseNoneNoneFalseNoneFalse1298.00
3611651131245NoneV-1,P.NO 6,IT.NO 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.84299.84224.0FalseNoneNoneFalseNoneFalse67164.160
3611652131245NoneV-1 P.NO 7 IT.NO 1.11Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum536.49536.49224.0FalseNoneNoneFalseNoneFalse120173.760
3611653131245NoneV-5 P.NO 134 IT.NO 10.3Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:" Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr764.46764.46300.0FalseNoneNoneFalseNoneFalse229338.00
3611654131245NoneV-5 P.NO 134 IT.NO 10.2.4Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ). - do - 160 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr713.66713.6670.0FalseNoneNoneFalseNoneFalse49956.20
3611655131245NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6757.516757.5145.0FalseNoneNoneFalseNoneFalse304087.950
3611656131245NoneV-5 P.NO 187 IT.NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6757.516757.5115.0FalseNoneNoneFalseNoneFalse101362.650
3611657131245None13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3197.863197.8625.0FalseNoneNoneFalseNoneFalse79946.50
3611658131245None16.18Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
3611659131245NoneV-2 P.NO 120 IT.NO 13.33Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 40mm DWS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr591.0591.080.0FalseNoneNoneFalseNoneFalse47280.00
3611660131245None13.23Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g) T. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1665.221665.225.0FalseNoneNoneFalseNoneFalse8326.10
3611661131245None13.40.1 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
3611662131245None13.32 V-5Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work." ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo8053.58053.52.0FalseNoneNoneFalseNoneFalse16107.00
17218282340000NoneNoneBuildingsNARAYANPUR IN SHORAPUR TALUK OF YADGIR DISTRICT (ELECTRICAL WORKS)4364380.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3611663131246NonePWD ELE SR V-6 IT.NO 2.2.1WIRES & CABLES Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint333.29333.2925.0FalseNoneNoneFalseNoneFalse8332.250
3611664131246NonePWD ELE SR V-10 IT.NO 2.2.2Point wiring using Copper wire without switch. "Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet." Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPack469.58469.5836.0FalseNoneNoneFalseNoneFalse16904.880
3611665131246NonePWD ELE SR V-11 IT.NO 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint687.65687.6563.0FalseNoneNoneFalseNoneFalse43321.950
3611666131246NonePWD ELE SR V-12 IT.NO 2.2.4Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint838.8838.88.0FalseNoneNoneFalseNoneFalse6710.40
3611667131246NonePWD ELE SR V-14 IT.NO 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach170.98170.9825.0FalseNoneNoneFalseNoneFalse4274.50
3611668131246NonePWD ELE SR V-15 IT.NO 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach197.0197.032.0FalseNoneNoneFalseNoneFalse6304.00
3611669131246NonePWD ELE SR V-16 IT.NO 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach219.3219.316.0FalseNoneNoneFalseNoneFalse3508.80
3611670131246NonePWD ELE SR V-17 IT.NO 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach272.58272.587.0FalseNoneNoneFalseNoneFalse1908.060
3611671131246NonePWD ELE SR V-18 IT.NO 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach323.38323.3820.0FalseNoneNoneFalseNoneFalse6467.60
3611672131246NonePWD ELE SR V-20 IT.NO 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach199.48199.4832.0FalseNoneNoneFalseNoneFalse6383.360
3611673131246NonePWD ELE SR V-21 IT.NO 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach216.83216.8316.0FalseNoneNoneFalseNoneFalse3469.280
3611674131246NonePWD ELE SR V-22 IT.NO 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach289.93289.937.0FalseNoneNoneFalseNoneFalse2029.510
3611675131246NonePWD ELE SR V-23 IT.NO 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach351.88351.8821.0FalseNoneNoneFalseNoneFalse7389.480
3611676131246NonePWD ELE SR V-24 IT.NO 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach426.22426.2231.0FalseNoneNoneFalseNoneFalse13212.820
3611677131246NonePWD ELE SR V-26 IT.NO 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach126.38126.38217.0FalseNoneNoneFalseNoneFalse27424.460
3611678131246NonePWD ELE SR V-6 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach205.67205.672.0FalseNoneNoneFalseNoneFalse411.340
3611679131246NonePWD ELE SR V-6,IT.NO 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach211.87211.8781.0FalseNoneNoneFalseNoneFalse17161.470
3611680131246NonePWD ELE SR V-6,IT.NO 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach442.32442.3224.0FalseNoneNoneFalseNoneFalse10615.680
3611681131246NonePWD ELE SR V-6,IT.NO 3.6.8Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach223.02223.0210.0FalseNoneNoneFalseNoneFalse2230.20
3611682131246NonePWD ELE SR V-6, IT.NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach403.91403.9115.0FalseNoneNoneFalseNoneFalse6058.650
3611683131246NonePWD ELE SR V-6,IT.NO 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach292.4292.425.0FalseNoneNoneFalseNoneFalse7310.00
3611684131246NonePWD ELE SR V-6,IT.NO 1.13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo144.96144.9624.0FalseNoneNoneFalseNoneFalse3479.040
3611685131246NonePWD ELE SR V-6,IT.NO-1.2.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr81.7781.77890.0FalseNoneNoneFalseNoneFalse72775.30
3611686131246NonePWD ELE SR V-6,IT.NO 1.2.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr96.6496.641030.0FalseNoneNoneFalseNoneFalse99539.20
3611687131246NonePWD ELE SR V-6, IT.NO .2.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr127.62127.62250.0FalseNoneNoneFalseNoneFalse31905.00
3611688131246NonePWD ELE SR V-6,IT.NO1.3.1Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr84.2584.25445.0FalseNoneNoneFalseNoneFalse37491.250
3611689131246NonePWD ELE SR V-6,IT.NO-1.3.2Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr97.8897.88515.0FalseNoneNoneFalseNoneFalse50408.20
3611690131246NonePWD ELE SR V-6,IT.NO-1.3.3Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr122.66122.66150.0FalseNoneNoneFalseNoneFalse18399.00
3611691131246NonePWD ELE SR V-6,IT.NO 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr32.2132.21470.0FalseNoneNoneFalseNoneFalse15138.70
3611692131246NonePWD ELE SR V-6,IT.NO 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr52.0452.041530.0FalseNoneNoneFalseNoneFalse79621.20
3611693131246NonePWD ELE SR V-6,IT.NO 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr78.0678.06740.0FalseNoneNoneFalseNoneFalse57764.40
3611694131246NonePWD ELE SR V-6,IT.NO 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr113.99113.99580.0FalseNoneNoneFalseNoneFalse66114.20
3611695131246NonePWD ELE SR V-6,IT.NO 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach5003.085003.082.0FalseNoneNoneFalseNoneFalse10006.160
3611696131246NonePWD ELE SR V-6,IT.NO 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach514.19514.1962.0FalseNoneNoneFalseNoneFalse31879.780
3611697131246NonePWD ELE SR V-6 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16) 40Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3771.523771.522.0FalseNoneNoneFalseNoneFalse7543.040
3611698131246NonePWD ELE SR V-6,IT.NO 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
3611699131246NonePWD ELE SR V-6,IT.NO 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach480.73480.7310.0FalseNoneNoneFalseNoneFalse4807.30
3611700131246NonePWD ELE SR V-6,IT.NO 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach39.6539.6516.0FalseNoneNoneFalseNoneFalse634.40
3611701131246NoneV-6 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4348.894348.897.0FalseNoneNoneFalseNoneFalse30442.230
3611702131246NoneV-6 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr101.6101.6100.0FalseNoneNoneFalseNoneFalse10160.00
3611703131246None12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600X600X3 GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1084.131084.136.0FalseNoneNoneFalseNoneFalse6504.780
3611704131246None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1096.521096.5219.0FalseNoneNoneFalseNoneFalse20833.880
3611705131246None11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo1640.441640.445.0FalseNoneNoneFalseNoneFalse8202.20
3611706131246None11.3.2Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo854.91854.9151.0FalseNoneNoneFalseNoneFalse43600.410
3611707131246None11.11.3Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo184.61184.6115.0FalseNoneNoneFalseNoneFalse2769.150
3611708131246NonePWD ELE SR V-6,IT.NO 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1848.591848.5913.0FalseNoneNoneFalseNoneFalse24031.670
3611709131246NonePWD ELE SR V-6,IT.NO 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3316.83316.824.0FalseNoneNoneFalseNoneFalse79603.20
3611710131246NonePWD ELE SR V-6,IT.NO 13.11Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach390.29390.2924.0FalseNoneNoneFalseNoneFalse9366.960
3611711131246NonePWD ELE SR V-6,IT.NO 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach151.16151.1683.0FalseNoneNoneFalseNoneFalse12546.280
3611712131246NonePWD ELE SR V-6,IT.NO 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach875.97875.9713.0FalseNoneNoneFalseNoneFalse11387.610
3611713131246NonePWD ELE SR V-6,IT.NO 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach200.72200.723.0FalseNoneNoneFalseNoneFalse602.160
3611714131246NonePWD ELE SR V-6,IT.NO 5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.5386000.0FalseNoneNoneFalseNoneFalse45580.00
3611715131246NonePWD ELE SR V-6,IT.NO 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr4255.974255.975.0FalseNoneNoneFalseNoneFalse21279.850
3611716131246NonePWD ELE SR V-6,IT.NO 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr377.9377.910.0FalseNoneNoneFalseNoneFalse3779.00
3611717131246NonePWD ELE SR V-6,IT.NO 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr936.68936.6810.0FalseNoneNoneFalseNoneFalse9366.80
3611718131246NonePWD ELE SR V-6,IT.NO 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) 100Amps 25kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach10515.3910515.391.0FalseNoneNoneFalseNoneFalse10515.390
3611719131246NonePWD ELE SR V-6,iT.NO 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3826.033826.0310.0FalseNoneNoneFalseNoneFalse38260.30
3611720131246NonePWD ELE SR V-6,IT.NO 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach11541.2911541.291.0FalseNoneNoneFalseNoneFalse11541.290
3611721131246NonePWD ELE SR V-6,IT.NO 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3611722131246NonePWD ELE SR V-6,IT.NO 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach696.32696.323.0FalseNoneNoneFalseNoneFalse2088.960
3611723131246NonePWD ELE SR V-6,IT.NO5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKvar594.72594.7215.0FalseNoneNoneFalseNoneFalse8920.80
3611724131246None5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
3611725131246None5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6120.666120.661.0FalseNoneNoneFalseNoneFalse6120.660
3611726131246None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3826.033826.031.0FalseNoneNoneFalseNoneFalse3826.030
3611727131246None5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo6377.136377.133.0FalseNoneNoneFalseNoneFalse19131.390
3611728131246None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm109549.9109549.90.1FalseNoneNoneFalseNoneFalse10954.990
3611729131246None32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm190882.82190882.820.05FalseNoneNoneFalseNoneFalse9544.1410
3611730131246None32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm393892.97393892.970.1FalseNoneNoneFalseNoneFalse39389.2970
3611731131246None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm25877.7525877.750.05FalseNoneNoneFalseNoneFalse1293.88750
3611732131246None31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm38581.2238581.220.2FalseNoneNoneFalseNoneFalse7716.2440
3611733131246None6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo15.4115.4120.0FalseNoneNoneFalseNoneFalse308.20
3611734131246None16.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
3611735131246None11.11.5Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo333.29333.299.0FalseNoneNoneFalseNoneFalse2999.610
3611736131246None11.6.3Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo5641.175641.178.0FalseNoneNoneFalseNoneFalse45129.360
3611737131246None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo4985.744985.742.0FalseNoneNoneFalseNoneFalse9971.480
3611738131246None13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1810.181810.183.0FalseNoneNoneFalseNoneFalse5430.540
3611739131246None5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach2738.192738.192.0FalseNoneNoneFalseNoneFalse5476.380
3611740131246None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach169.74169.7424.0FalseNoneNoneFalseNoneFalse4073.760
3611741131246None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach395.24395.2431.0FalseNoneNoneFalseNoneFalse12252.440
3611742131246None2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint1225.371225.374.0FalseNoneNoneFalseNoneFalse4901.480
3611743131246None6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
3611744131246None12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach78.0678.0621.0FalseNoneNoneFalseNoneFalse1639.260
3611745131246None3.6.11TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach193.28193.282.0FalseNoneNoneFalseNoneFalse386.560
3611746131246None12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach304.79304.791.0FalseNoneNoneFalseNoneFalse304.790
3611747131246None32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm98168.4598168.450.1FalseNoneNoneFalseNoneFalse9816.8450
3611748131246None31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm25877.7525877.750.1FalseNoneNoneFalseNoneFalse2587.7750
3611749131246Nonepwd srSupplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr15.4115.4115.0FalseNoneNoneFalseNoneFalse231.150
3611750131246None11..11.7Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach527.81527.813.0FalseNoneNoneFalseNoneFalse1583.430
3611751131246None12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach64.4364.432.0FalseNoneNoneFalseNoneFalse128.860
3611752131246None11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo3004.583004.581.0FalseNoneNoneFalseNoneFalse3004.580
3611753131246None5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach298.6298.61.0FalseNoneNoneFalseNoneFalse298.60
3611754131246None5.30Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1709.821709.821.0FalseNoneNoneFalseNoneFalse1709.820
3611755131246None7.1.3Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach12689.8412689.841.0FalseNoneNoneFalseNoneFalse12689.840
3611756131246NonePWD SR 2023-24 Volume 6 It No-9.3.3Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach84726.5484726.541.0FalseNoneNoneFalseNoneFalse84726.540
3611757131246NonePWD SR 2023-24 Volume 6 It No-9.5.9Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach19693.9119693.914.0FalseNoneNoneFalseNoneFalse78775.640
3611758131246NoneA.RItem Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workJob300000.0300000.01.0FalseNoneNoneFalseNoneFalse300000.00
3611759131246NoneLQRIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach23836.023836.04.0FalseNoneNoneFalseNoneFalse95344.00
3611760131246NoneLQRIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach25606.025606.02.0FalseNoneNoneFalseNoneFalse51212.00
3611761131246NoneLQRSupplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3611762131246NoneLQRSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach17110.017110.02.0FalseNoneNoneFalseNoneFalse34220.00
3611763131246NoneLQRSupply and Installation of I/Os ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach147.5147.512.0FalseNoneNoneFalseNoneFalse1770.00
3611764131246NoneLQRSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach265.5265.512.0FalseNoneNoneFalseNoneFalse3186.00
3611765131246NoneLQRSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach336.3336.36.0FalseNoneNoneFalseNoneFalse2017.80
3611766131246NoneLQRSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3611767131246NoneV-6 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr47.0847.08600.0FalseNoneNoneFalseNoneFalse28248.00
3611768131246None1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach96.6496.64500.0FalseNoneNoneFalseNoneFalse48320.00
3611769131246None8.12.3Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3778.953778.951.0FalseNoneNoneFalseNoneFalse3778.950
3611770131246None8.4.1 v-6Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach6061.196061.191.0FalseNoneNoneFalseNoneFalse6061.190
3611771131246None1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet8767.168767.168.0FalseNoneNoneFalseNoneFalse70137.280
3611772131246None2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet1379.011379.018.0FalseNoneNoneFalseNoneFalse11032.080
3611773131246None6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo107.79107.796.0FalseNoneNoneFalseNoneFalse646.740
3611774131246None13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo59.4759.476.0FalseNoneNoneFalseNoneFalse356.820
3611775131246None2.16Supply of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo296.12296.1211.0FalseNoneNoneFalseNoneFalse3257.320
3611776131246None2.16Erection of Spiral Earth Electrode ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo115.23115.2311.0FalseNoneNoneFalseNoneFalse1267.530
3611777131246None68.17Supply and fixing of Caution/Danger Board ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3611778131246None4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach110.27110.278.0FalseNoneNoneFalseNoneFalse882.160
3611779131246None5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach52.0452.048.0FalseNoneNoneFalseNoneFalse416.320
3611780131246None24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet26341.1426341.141.0FalseNoneNoneFalseNoneFalse26341.140
3611781131246None24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo7521.977521.971.0FalseNoneNoneFalseNoneFalse7521.970
3611782131246None25.01Supply of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet of 3 Nos7279.137279.131.0FalseNoneNoneFalseNoneFalse7279.130
3611783131246None13.01Erection of DOLO Cut Out ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet of 3 Nos293.64293.641.0FalseNoneNoneFalseNoneFalse293.640
3611784131246None13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach210958.34210958.341.0FalseNoneNoneFalseNoneFalse210958.340
3611785131246None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach4348.894348.898.0FalseNoneNoneFalseNoneFalse34791.120
3611786131246None12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMT158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
3611787131246None12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr2035.682035.68100.0FalseNoneNoneFalseNoneFalse203568.00
3611788131246None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach9194.629194.6210.0FalseNoneNoneFalseNoneFalse91946.20
3611789131246None45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
3611790131246None45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
3611791131246None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
3611792131246None38.Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1222.891222.89150.0FalseNoneNoneFalseNoneFalse183433.50
3611793131246None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSq CM0.530.53176000.0FalseNoneNoneFalseNoneFalse93280.00
3611794131246None5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr4255.974255.976.0FalseNoneNoneFalseNoneFalse25535.820
3611795131246None5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr377.9377.912.0FalseNoneNoneFalseNoneFalse4534.80
3611796131246None5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr936.68936.6812.0FalseNoneNoneFalseNoneFalse11240.160
3611797131246None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach29172.2629172.261.0FalseNoneNoneFalseNoneFalse29172.260
3611798131246None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach638.09638.093.0FalseNoneNoneFalseNoneFalse1914.270
3611799131246None10.1.3Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet558914.14558914.141.0FalseNoneNoneFalseNoneFalse558914.140
3611800131246None10.2.2Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach72742.9372742.931.0FalseNoneNoneFalseNoneFalse72742.930
3611801131246NoneA.RSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr3540.03540.05.0FalseNoneNoneFalseNoneFalse17700.00
3611802131246NoneA.RSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workRmtr236.0236.050.0FalseNoneNoneFalseNoneFalse11800.00
3611803131246None58.02LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo98973.898973.81.0FalseNoneNoneFalseNoneFalse98973.80
3611804131246None53.01CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach24302.9924302.991.0FalseNoneNoneFalseNoneFalse24302.990
3611805131246None10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach173.46173.4615.0FalseNoneNoneFalseNoneFalse2601.90
3611806131246Nonev-6 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet603.39603.396.0FalseNoneNoneFalseNoneFalse3620.340
3611807131246Nonev-6 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL" ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet318.42318.426.0FalseNoneNoneFalseNoneFalse1910.520
3611808131246Nonev-6 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) " ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo254.0254.018.0FalseNoneNoneFalseNoneFalse4572.00
3611809131246Nonev-6 6.10Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo235.45235.4518.0FalseNoneNoneFalseNoneFalse4238.10
3611810131246None13.12 v-6Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo59.4759.4718.0FalseNoneNoneFalseNoneFalse1070.460
3611811131246Nonev-6 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet73.173.14.0FalseNoneNoneFalseNoneFalse292.40
3611812131246None7.02Supply of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm57283.9357283.931.0FalseNoneNoneFalseNoneFalse57283.930
3611813131246None6.02 V-6Erection of Rabbit ACSR Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKm5403.285403.281.0FalseNoneNoneFalseNoneFalse5403.280
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17218282370000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17218282370000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17218282370001NoneNoneELIGIBILITYBidders shall ensure upload ESI and EFP registration certificateNone
17218282370000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17218282370000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17218851930000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17218852050000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17218852120000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17218852190000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17218852260000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete mannerNone
17218852310000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to timeNone
17218852360000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejectedNone
17218852410000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tenderNone
17218852470000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17218852560000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17218852610000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of executionNone
17218852670000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified timeNone
17218852720000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
17218852800000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the workNone
17218852860000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17218852920000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GSTNone
17218852960000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid documentNone
17218853010000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the workNone
17218853200000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21 2021-22, 2022-23 & 2023-24.None
17218853280000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least one Similar work of value not less than Rs.1217.00 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24).Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation 16610.00 Cum,2)RCC and PCC 4813.00Cum,3)Steel Reinforcement for RCC work 284.00 tonne, 4)Cement Concrete Block Masonry/Solid Block Masonry /Load Bearing Wall/BBM 8562.00Sqm, 5)Flooring/Dadooing(Vitrified/Granite/Ceramic/Cement concrete/cladding/dadooing) 6286.00Sqm, 6)Plastering 26405.00 Sqm, 7)Painting 23590.00 Sqm, 8) MS Girls 8965.00 kgs, 9)WPC 5140.00 Sqm. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2(c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24).The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.153.00 Lakhs in any one financial year.Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d).The letter of willingness of the sub contractor to be engaged for electrical, should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(e)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24.The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.95.00 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e).The letter of willingness of the sub contractor to be engaged for water supply & Sanitary, should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No Position Qualification and Requirement No of Persons. (1) Project Manager B.E. Civil with minimum experience of 15 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One) (2)Site Engineer B.E. Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years. 3 (three), (3)Electrical Engineer B.E. Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One).Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates should be uploaded
NoneNoneNoneNoneKPWD Class-I Registration Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- REGISTRATION CERTIFICATE ISSUED BY COMPETENT AUTHORITY
NoneNoneNoneNoneClause ITT 3.3 (a)Equipment capacity Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50% can be deployed on ease/hire basis for all works provided, the relevant documents (commitment agreements etc.,) for availability for this work are furnished. Sl.No. Description of Equipment Quantity 1) Min 10 cft capacity Concrete Mixer -3Nos, 2) Centering sheets-3500 Sqmtr, 3) Tipper-2 Nos, 4) Water Tanker-4Nos, 5) Bar Bending and cutting machine-2Nos, 6) Excavator-2 Nos.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Invoices and receipt to be uploaded
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2019-20 to 2023-24 updated to 2024-25 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2024-25 price level of existing commitments and ongoing works to be completed during the next 15 months. Note The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- list of existing commitments and on-going works
NoneNoneNoneNoneClause ITT 3.2(a):To qualify for award of this contract, each Tenderer in his / its name should have in the last five years i.e.(2019-20 to 2023-24).The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs. 3894.50 Lakhs. Note: For Clause 3.2 (a) the Turn over certificate and balance sheet duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.585.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate and balance sheet issued by charted accountantTrueTechnical Bid
KPWD Registration Certificate Class-ITrueTechnical Bid
ESI and PF certificate and latest paid receiptTrueTechnical Bid
GST certificate and latest paid receiptTrueTechnical Bid
Workdone certificate issued by the officer not below the rank of EETrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1721889334000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, HFWD, Arogya Soudha, 3rd Floor, 1st Cross Magadi Road
streetNone
cityBengalruu
stateKarnataka
pin560023
tenderRecallDTONone