tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1721828233000 | 0 | None | None | Buildings | MUDABULL IN SHAHAPUR TALUK OF YADGIR DISTRICT. (CIVIL) | 27665191.48 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3609362 | 131234 | None | CSR:V-3 PAGE NO 9 Itm 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | 100 Sqm | 486.93 | 486.93 | 17.49 | False | None | None | False | None | False | 8516.4057 | 0 | 3609363 | 131234 | None | V-1 page 8 itm 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 117.71 | 117.71 | 768.64 | False | None | None | False | None | False | 90476.6144 | 0 | 3609364 | 131234 | None | V-1page 8 itm 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 126.38 | 126.38 | 1311.57 | False | None | None | False | None | False | 165756.2166 | 0 | 3609365 | 131234 | None | V-1page 8 itm 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 449.76 | 449.76 | 230.53 | False | None | None | False | None | False | 103683.1728 | 0 | 3609366 | 131234 | None | V-3page 3 A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 167.27 | 167.27 | 225.13 | False | None | None | False | None | False | 37657.4951 | 0 | 3609367 | 131234 | None | V-2page5 itm 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 146.2 | 146.2 | 774.16 | False | None | None | False | None | False | 113182.192 | 0 | 3609368 | 131234 | None | V-1pg7 itm1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 329.57 | 329.57 | 807.35 | False | None | None | False | None | False | 266078.3395 | 0 | 3609369 | 131234 | None | V-1page7vitm1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 587.29 | 587.29 | 728.89 | False | None | None | False | None | False | 428069.8081 | 0 | 3609370 | 131234 | None | V-1page 15 itm2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7420.37 | 7420.37 | 161.37 | False | None | None | False | None | False | 1197425.1069 | 0 | 3609371 | 131234 | None | V-1page15 itm 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8478.33 | 8478.33 | 177.95 | False | None | None | False | None | False | 1508718.8235 | 0 | 3609372 | 131234 | None | V-1page16 itm 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8635.33 | 8635.33 | 13.4 | False | None | None | False | None | False | 115713.422 | 0 | 3609373 | 131234 | None | V-1page15itm 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 14413.41 | 14413.41 | 55.14 | False | None | None | False | None | False | 794755.4274 | 0 | 3609374 | 131234 | None | V-3page135itm15.4 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 252.76 | 252.76 | 13.0 | False | None | None | False | None | False | 3285.88 | 0 | 3609375 | 131234 | None | V-2page55 itm 8.16.a | Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1533.88 | 1533.88 | 13.81 | False | None | None | False | None | False | 21182.8828 | 0 | 3609376 | 131234 | None | V-1page18itm2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Tonne | 110837.22 | 110837.22 | 50.82 | False | None | None | False | None | False | 5632747.5204 | 0 | 3609377 | 131234 | None | 18-19SR ITM4.21 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 38.94 | 38.94 | 145.02 | False | None | None | False | None | False | 5647.0788 | 0 | 3609378 | 131234 | None | DATA RATE | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 86.14 | 86.14 | 145.02 | False | None | None | False | None | False | 12492.0228 | 0 | 3609379 | 131234 | None | V-2PAGE 9 ITM5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7915.97 | 7915.97 | 8.76 | False | None | None | False | None | False | 69343.8972 | 0 | 3609380 | 131234 | None | V-2PAGE 14 ITM 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1623.09 | 1623.09 | 1313.93 | False | None | None | False | None | False | 2132626.6437 | 0 | 3609381 | 131234 | None | V-2page 14 itm 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks
of size 400x100x200mm having block density more than 1800kg/m3
and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005
including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1367.86 | 1367.86 | 171.24 | False | None | None | False | None | False | 234232.3464 | 0 | 3609382 | 131234 | None | V-2 page100 itm 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 122431.79 | 122431.79 | 1.2 | False | None | None | False | None | False | 146918.148 | 0 | 3609383 | 131234 | None | V-2 page 105 itm 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 1258.82 | 1258.82 | 32.0 | False | None | None | False | None | False | 40282.24 | 0 | 3609384 | 131234 | None | 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 681.45 | 681.45 | 64.0 | False | None | None | False | None | False | 43612.8 | 0 | 3609385 | 131234 | None | 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 464.63 | 464.63 | 32.0 | False | None | None | False | None | False | 14868.16 | 0 | 3609386 | 131234 | None | 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 185.85 | 185.85 | 64.0 | False | None | None | False | None | False | 11894.4 | 0 | 3609387 | 131234 | None | 22.15.9 | PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 86.73 | 86.73 | 128.0 | False | None | None | False | None | False | 11101.44 | 0 | 3609388 | 131234 | None | 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 123.9 | 123.9 | 32.0 | False | None | None | False | None | False | 3964.8 | 0 | 3609389 | 131234 | None | 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 1303.43 | 1303.43 | 32.0 | False | None | None | False | None | False | 41709.76 | 0 | 3609390 | 131234 | None | V-2page69 itm 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 74.34 | 74.34 | 192.0 | False | None | None | False | None | False | 14273.28 | 0 | 3609391 | 131234 | None | 20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 64.43 | 64.43 | 168.45 | False | None | None | False | None | False | 10853.2335 | 0 | 3609392 | 131234 | None | V-2page105 itm 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4115.96 | 4115.96 | 74.84 | False | None | None | False | None | False | 308038.4464 | 0 | 3609393 | 131234 | None | V-2page109 itm 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 8343.43 | 8343.43 | 69.39 | False | None | None | False | None | False | 578950.6077 | 0 | 3609394 | 131234 | None | V-2page109 itm 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 7085.84 | 7085.84 | 6.84 | False | None | None | False | None | False | 48467.1456 | 0 | 3609395 | 131234 | None | V-2page 86itm11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 208.15 | 208.15 | 1600.83 | False | None | None | False | None | False | 333212.7645 | 0 | 3609396 | 131234 | None | V-2page 111itm 12.93.1 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/
cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | m | 869.78 | 869.78 | 64.35 | False | None | None | False | None | False | 55970.343 | 0 | 3609397 | 131234 | None | V-2page84 itm 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kgs | 168.5 | 168.5 | 1724.91 | False | None | None | False | None | False | 290647.335 | 0 | 3609398 | 131234 | None | V-2page 41itm 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 386.57 | 386.57 | 1763.82 | False | None | None | False | None | False | 681839.8974 | 0 | 3609399 | 131234 | None | V-2page 43 itm 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 261.43 | 261.43 | 1176.83 | False | None | None | False | None | False | 307658.6669 | 0 | 3609400 | 131234 | None | V-2page50 itm 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 123.9 | 123.9 | 2919.03 | False | None | None | False | None | False | 361667.817 | 0 | 3609401 | 131234 | None | V-2page42itm 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 432.41 | 432.41 | 975.48 | False | None | None | False | None | False | 421807.3068 | 0 | 3609402 | 131234 | None | V-2page41 itm 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 438.61 | 438.61 | 163.05 | False | None | None | False | None | False | 71515.3605 | 0 | 3609403 | 131234 | None | 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 47.08 | 47.08 | 2013.85 | False | None | None | False | None | False | 94812.058 | 0 | 3609404 | 131234 | None | 10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 254.88 | 254.88 | 13.0 | False | None | None | False | None | False | 3313.44 | 0 | 3609405 | 131234 | None | V-2page 54itm 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 64.43 | 64.43 | 628.05 | False | None | None | False | None | False | 40465.2615 | 0 | 3609406 | 131234 | None | V-2page61itm 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1455.83 | 1455.83 | 580.89 | False | None | None | False | None | False | 845677.0887 | 0 | 3609407 | 131234 | None | V-2page59 itm9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 991.2 | 991.2 | 71.5 | False | None | None | False | None | False | 70870.8 | 0 | 3609408 | 131234 | None | V-2page63 itm 9.32 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3199.1 | 3199.1 | 34.54 | False | None | None | False | None | False | 110496.914 | 0 | 3609409 | 131234 | None | V-2page 4 itm 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 365.51 | 365.51 | 316.07 | False | None | None | False | None | False | 115526.7457 | 0 | 3609410 | 131234 | None | V-2page 60 itm 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1101.47 | 1101.47 | 59.14 | False | None | None | False | None | False | 65140.9358 | 0 | 3609411 | 131234 | None | V-2page65 itmv9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1795.31 | 1795.31 | 259.57 | False | None | None | False | None | False | 466008.6167 | 0 | 3609412 | 131234 | None | V-2 page85 itm11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 700.04 | 700.04 | 357.82 | False | None | None | False | None | False | 250488.3128 | 0 | 3609413 | 131234 | None | V-2 page 48itm 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 157.35 | 157.35 | 2741.14 | False | None | None | False | None | False | 431318.379 | 0 | 3609414 | 131234 | None | V-2page 46itm8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 193.28 | 193.28 | 759.66 | False | None | None | False | None | False | 146827.0848 | 0 | 3609415 | 131234 | None | V-2page47 itm8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 61.95 | 61.95 | 96.21 | False | None | None | False | None | False | 5960.2095 | 0 | 3609416 | 131234 | None | V-2page48 itm 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 142.49 | 142.49 | 76.23 | False | None | None | False | None | False | 10862.0127 | 0 | 3609417 | 131234 | None | V-2page47itm 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 65.67 | 65.67 | 179.6 | False | None | None | False | None | False | 11794.332 | 0 | 3609418 | 131234 | None | 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 838.8 | 838.8 | 179.6 | False | None | None | False | None | False | 150648.48 | 0 | 3609419 | 131234 | None | V-2page64itm 9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 2044.35 | 2044.35 | 17.32 | False | None | None | False | None | False | 35408.142 | 0 | 3609420 | 131234 | None | V-2page77 itm 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 5548.24 | 5548.24 | 5.25 | False | None | None | False | None | False | 29128.26 | 0 | 3609421 | 131234 | None | 15.12 | Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1443.44 | 1443.44 | 726.5 | False | None | None | False | None | False | 1048659.16 | 0 | 3609422 | 131234 | None | V-2PAGE22 ITM 7.17 | Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 411.35 | 411.35 | 24.74 | False | None | None | False | None | False | 10176.799 | 0 | 3609423 | 131234 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 102.35 | False | None | None | False | None | False | 1301658.642 | 0 | 3609424 | 131234 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 13565.56 | 13565.56 | 51.01 | False | None | None | False | None | False | 691979.2156 | 0 | 3609425 | 131234 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 115.4 | False | None | None | False | None | False | 1467624.888 | 0 | 3609426 | 131234 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 7.07 | False | None | None | False | None | False | 89914.2804 | 0 | 3609427 | 131234 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 13565.56 | 13565.56 | 12.12 | False | None | None | False | None | False | 164414.5872 | 0 | 3609428 | 131234 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 11911.13 | 11911.13 | 14.18 | False | None | None | False | None | False | 168899.8234 | 0 | 3609429 | 131234 | None | 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4317.92 | 4317.92 | 20.48 | False | None | None | False | None | False | 88431.0016 | 0 | 3609430 | 131234 | None | 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 141.25 | 141.25 | 36.0 | False | None | None | False | None | False | 5085.0 | 0 | 3609431 | 131234 | None | 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1642.91 | 1642.91 | 56.5 | False | None | None | False | None | False | 92824.415 | 0 | 3609432 | 131234 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 6601.39 | 6601.39 | 30.54 | False | None | None | False | None | False | 201606.4506 | 0 | 3609433 | 131234 | None | 10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4877.94 | 4877.94 | 9.69 | False | None | None | False | None | False | 47267.2386 | 0 | 3609434 | 131234 | None | 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 761.99 | 761.99 | 92.01 | False | None | None | False | None | False | 70110.6999 | 0 | 3609435 | 131234 | None | 8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 350.64 | 350.64 | 215.82 | False | None | None | False | None | False | 75675.1248 | 0 | 3609436 | 131234 | None | 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 360.55 | 360.55 | 68.92 | False | None | None | False | None | False | 24849.106 | 0 | 3609437 | 131234 | None | 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3533.63 | 3533.63 | 11.09 | False | None | None | False | None | False | 39187.9567 | 0 | 3609438 | 131234 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 6601.39 | 6601.39 | 13.73 | False | None | None | False | None | False | 90637.0847 | 0 | 3609439 | 131234 | None | 10.1.1 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4963.43 | 4963.43 | 3.81 | False | None | None | False | None | False | 18910.6683 | 0 | 3609440 | 131234 | None | 1.4.1 V-1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 299.84 | 299.84 | 11.06 | False | None | None | False | None | False | 3316.2304 | 0 | 3609441 | 131234 | None | 1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 320.9 | 320.9 | 1.7 | False | None | None | False | None | False | 545.53 | 0 | 3609442 | 131234 | None | 17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1391.4 | 1391.4 | 7.0 | False | None | None | False | None | False | 9739.8 | 0 | 3609443 | 131234 | None | 17.1 V-2 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1241.48 | 1241.48 | 0.28 | False | None | None | False | None | False | 347.6144 | 0 | 3609444 | 131234 | None | 17.2 V-2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1469.45 | 1469.45 | 0.14 | False | None | None | False | None | False | 205.723 | 0 | 3609445 | 131234 | None | 17. V-2 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1476.89 | 1476.89 | 0.14 | False | None | None | False | None | False | 206.7646 | 0 | 3609446 | 131234 | None | 17.4 V-2 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1659.02 | 1659.02 | 0.14 | False | None | None | False | None | False | 232.2628 | 0 | 3609447 | 131234 | None | 17.14 V-2 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1449.63 | 1449.63 | 1.0 | False | None | None | False | None | False | 1449.63 | 0 | 3609448 | 131234 | None | V3 305.3.4 | Compacting Original Ground
Compacting original ground supporting embankment
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 130.1 | 130.1 | 72.0 | False | None | None | False | None | False | 9367.2 | 0 | 3609449 | 131234 | None | V-3 4.2 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 2922.8 | 2922.8 | 36.0 | False | None | None | False | None | False | 105220.8 | 0 | 3609450 | 131234 | None | V3 6.1 ISSUE RATE | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 6095.88 | 6095.88 | 24.0 | False | None | None | False | None | False | 146301.12 | 0 | 3609451 | 131234 | None | V-3 6.2 ISSUE RATE | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 11107.64 | 11107.64 | 48.0 | False | None | None | False | None | False | 533166.72 | 0 | 3609452 | 131234 | None | V-3 8.10 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 105.32 | 105.32 | 15.0 | False | None | None | False | None | False | 1579.8 | 0 | 3609453 | 131234 | None | V-3 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 87.97 | 87.97 | 448.0 | False | None | None | False | None | False | 39410.56 | 0 | 3609454 | 131234 | None | V-314621A | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)
300 x 250 x 100 mm Kerb Stone
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 296.12 | 296.12 | 150.0 | False | None | None | False | None | False | 44418.0 | 0 | 3609455 | 131234 | None | 2.1.4 V-1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7702.86 | 7702.86 | 2.0 | False | None | None | False | None | False | 15405.72 | 0 | 3609456 | 131234 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 9156.76 | 9156.76 | 10.8 | False | None | None | False | None | False | 98893.008 | 0 | 3609457 | 131234 | None | 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 459.67 | 459.67 | 320.0 | False | None | None | False | None | False | 147094.4 | 0 | 3609458 | 131234 | None | 8.31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 220.54 | 220.54 | 320.0 | False | None | None | False | None | False | 70572.8 | 0 | 3609459 | 131234 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8761.09 | 8761.09 | 9.36 | False | None | None | False | None | False | 82003.8024 | 0 | 3609460 | 131234 | None | 8.20 V-3 | Providing and fixing 1.8 m high GI barbed wire fencing with
2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete,
0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 672.78 | 672.78 | 390.0 | False | None | None | False | None | False | 262384.2 | 0 | 3609461 | 131234 | None | V1 1.15.2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 526.58 | 526.58 | 22.51 | False | None | None | False | None | False | 11853.3158 | 0 | 3609462 | 131234 | None | 2.5.2 V1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8732.83 | 8732.83 | 4.32 | False | None | None | False | None | False | 37725.8256 | 0 | 3609463 | 131234 | None | 2.5.2 V1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 9326.32 | 9326.32 | 5.89 | False | None | None | False | None | False | 54932.0248 | 0 | 3609464 | 131234 | None | V2 15.14 | UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 2072.85 | 2072.85 | 36.6 | False | None | None | False | None | False | 75866.31 | 0 | 3609465 | 131234 | None | V5 18.3 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2430.92 | 2430.92 | 8.0 | False | None | None | False | None | False | 19447.36 | 0 | 3609466 | 131234 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 14413.41 | 14413.41 | 9.87 | False | None | None | False | None | False | 142260.3567 | 0 | 3609467 | 131234 | None | 15.5 V-2 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 749.6 | 749.6 | 63.57 | False | None | None | False | None | False | 47652.072 | 0 | 3609468 | 131234 | None | 8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 110.27 | 110.27 | 20.1 | False | None | None | False | None | False | 2216.427 | 0 | 3609469 | 131234 | None | V-5P140I12.4 | Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3609470 | 131234 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3609471 | 131234 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above 50 Mtrs and upto 100 Mtr
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3609472 | 131234 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above100 Mtrs. and upto 150 Mtr
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3609473 | 131234 | None | V-5P143I12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 2394.99 | 2394.99 | 20.0 | False | None | None | False | None | False | 47899.8 | 0 | 3609474 | 131234 | None | V-5P155I13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 681.45 | 681.45 | 150.0 | False | None | None | False | None | False | 102217.5 | 0 | 3609475 | 131234 | None | V-5P143I12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3609476 | 131234 | None | V-5P154I12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3609477 | 131234 | None | 18-19 SR13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3609478 | 131234 | None | V-5P154I13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.
5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 39817.74 | 39817.74 | 1.0 | False | None | None | False | None | False | 39817.74 | 0 | 3609479 | 131234 | None | V-5P155I13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3609480 | 131234 | None | V-5P155I13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3609481 | 131234 | None | V-5P155I13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3609482 | 131234 | None | V-5P156I13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3609483 | 131234 | None | V-5P156I13.33 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 1672.65 | 1672.65 | 1.0 | False | None | None | False | None | False | 1672.65 | 0 | 3609484 | 131234 | None | 2.6.2 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 208.15 | 208.15 | 165.0 | False | None | None | False | None | False | 34344.75 | 0 | 3609485 | 131234 | None | V-5P20I5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete
16 SWG
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3609486 | 131234 | None | V-5P21I5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.
600mmx600mmx170mm.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3609487 | 131234 | None | 5.6.6 V-6 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 404.08 | 404.08 | 1.0 | False | None | None | False | None | False | 404.08 | 0 | 3609488 | 131234 | None | 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 514.19 | 514.19 | 1.0 | False | None | None | False | None | False | 514.19 | 0 | 3609489 | 131234 | None | 13.18.1 | Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 344.44 | 344.44 | 1.0 | False | None | None | False | None | False | 344.44 | 0 | 3609490 | 131234 | None | 5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kvar | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 |
| 1721828233000 | 0 | None | None | Buildings | MUDABULL WATER SUPPLY AND SANITARY WORKS | 2711710.47 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3609491 | 131235 | None | V-2 13.50.5 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work
40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 376.66 | 376.66 | 50.0 | False | None | None | False | None | False | 18833.0 | 0 | 3609492 | 131235 | None | V-2 13.50.6 | Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 478.25 | 478.25 | 20.0 | False | None | None | False | None | False | 9565.0 | 0 | 3609493 | 131235 | None | V-2 13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 358.07 | 358.07 | 185.0 | False | None | None | False | None | False | 66242.95 | 0 | 3609494 | 131235 | None | V-2 13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 477.02 | 477.02 | 120.0 | False | None | None | False | None | False | 57242.4 | 0 | 3609495 | 131235 | None | V-2 IT.NO 13.47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 244.08 | 244.08 | 35.0 | False | None | None | False | None | False | 8542.8 | 0 | 3609496 | 131235 | None | V-2 IT.NO 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 360.55 | 360.55 | 50.0 | False | None | None | False | None | False | 18027.5 | 0 | 3609497 | 131235 | None | V-2 P.NO 128 IT.NO 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 302.32 | 302.32 | 55.0 | False | None | None | False | None | False | 16627.6 | 0 | 3609498 | 131235 | None | V-2 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed
to wooden cleats with C.P. brass screws and washers complete."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1511.58 | 1511.58 | 21.0 | False | None | None | False | None | False | 31743.18 | 0 | 3609499 | 131235 | None | V-2 P.NO 127 IT.NO 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6891.32 | 6891.32 | 4.0 | False | None | None | False | None | False | 27565.28 | 0 | 3609500 | 131235 | None | V-2 P.NO 130 IT.NO 14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 614.54 | 614.54 | 4.0 | False | None | None | False | None | False | 2458.16 | 0 | 3609501 | 131235 | None | V-2 P.NO 123 IT.NO 14.38 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of
the same materials with snap fittings of approved quality and colour,
weighing not less than 105 g"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 179.66 | 179.66 | 4.0 | False | None | None | False | None | False | 718.64 | 0 | 3609502 | 131235 | None | V-2 P.NO 178 IT.NO 14.3.1 | Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush
bend, overflow arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete, including
painting of fittings and brackets, cutting and making good the walls and
floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 7405.5 | 7405.5 | 9.0 | False | None | None | False | None | False | 66649.5 | 0 | 3609503 | 131235 | None | V-2 P.NO 124 IT.NO14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6051.28 | 6051.28 | 10.0 | False | None | None | False | None | False | 60512.8 | 0 | 3609504 | 131235 | None | V-2 P.NO 126 IT.NO 14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6296.6 | 6296.6 | 2.0 | False | None | None | False | None | False | 12593.2 | 0 | 3609505 | 131235 | None | V-2 P.NO 126 IT.NO 14.10.1.1 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per
IS:13983 with C.I. brackets and stainless steel plug 40 mm, including
painting of fittings and brackets, cutting and making good the walls
wherever required : (510x1040 mm bowl depth 250 mm)"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6960.7 | 6960.7 | 4.0 | False | None | None | False | None | False | 27842.8 | 0 | 3609506 | 131235 | None | V-2 13.15 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 898.28 | 898.28 | 12.0 | False | None | None | False | None | False | 10779.36 | 0 | 3609507 | 131235 | None | V-2 P.NO 124 IT.NO 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3818.6 | 3818.6 | 13.0 | False | None | None | False | None | False | 49641.8 | 0 | 3609508 | 131235 | None | V-2 P.NO 120 IT.NO 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 382.85 | 382.85 | 90.0 | False | None | None | False | None | False | 34456.5 | 0 | 3609509 | 131235 | None | V-2 P.NO 120 IT.NO 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 469.58 | 469.58 | 70.0 | False | None | None | False | None | False | 32870.6 | 0 | 3609510 | 131235 | None | V-2 p.NO 120 IT.NO 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
25 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 70.0 | False | None | None | False | None | False | 41370.0 | 0 | 3609511 | 131235 | None | V-2 P.NO 120 IT.NO 13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
32 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 690.12 | 690.12 | 30.0 | False | None | None | False | None | False | 20703.6 | 0 | 3609512 | 131235 | None | V-2 P.NO 120 IT.NO 13.31.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
40 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 664.1 | 664.1 | 20.0 | False | None | None | False | None | False | 13282.0 | 0 | 3609513 | 131235 | None | V-2 P.NO 120IT.NO 13.31.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
50 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 967.66 | 967.66 | 20.0 | False | None | None | False | None | False | 19353.2 | 0 | 3609514 | 131235 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
20mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 268.86 | 268.86 | 50.0 | False | None | None | False | None | False | 13443.0 | 0 | 3609515 | 131235 | None | V-2 P.NO 120 IT.NO 13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
25mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 366.74 | 366.74 | 50.0 | False | None | None | False | None | False | 18337.0 | 0 | 3609516 | 131235 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
40mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 215.0 | False | None | None | False | None | False | 127065.0 | 0 | 3609517 | 131235 | None | V-2 P.NO 120 IT.NO 13.33.7 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
65mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 1734.6 | 1734.6 | 25.0 | False | None | None | False | None | False | 43365.0 | 0 | 3609518 | 131235 | None | V-2 P.NO 120 IT.NO 13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
50mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 893.32 | 893.32 | 40.0 | False | None | None | False | None | False | 35732.8 | 0 | 3609519 | 131235 | None | V2 13.5.2 | Providing and fixing ball valve (brass) of approved quality, High or low
pressure, with plastic floats complete :"
25 mm nominal bore
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 411.35 | 411.35 | 12.0 | False | None | None | False | None | False | 4936.2 | 0 | 3609520 | 131235 | None | V2-13.4 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 32 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 740.92 | 740.92 | 7.0 | False | None | None | False | None | False | 5186.44 | 0 | 3609521 | 131235 | None | V-2 13.4.3 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 40 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 869.78 | 869.78 | 9.0 | False | None | None | False | None | False | 7828.02 | 0 | 3609522 | 131235 | None | v2-13.4.4 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 50 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1059.35 | 1059.35 | 2.0 | False | None | None | False | None | False | 2118.7 | 0 | 3609523 | 131235 | None | V-2,A-13, IT.NO 13.2.1 | Brass bib-cock 15 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 354.35 | 354.35 | 19.0 | False | None | None | False | None | False | 6732.65 | 0 | 3609524 | 131235 | None | V-2 IT.NO 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Ltr | 11.15 | 11.15 | 3000.0 | False | None | None | False | None | False | 33450.0 | 0 | 3609525 | 131235 | None | V2 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 182.13 | 182.13 | 125.0 | False | None | None | False | None | False | 22766.25 | 0 | 3609526 | 131235 | None | Market Rate | Providing and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 177.0 | 177.0 | 55.0 | False | None | None | False | None | False | 9735.0 | 0 | 3609527 | 131235 | None | Market Rate | Air Vent Cowel
75mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 413.0 | 413.0 | 12.0 | False | None | None | False | None | False | 4956.0 | 0 | 3609528 | 131235 | None | Market Rate | Air Vent Cowel
110mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 590.0 | 590.0 | 12.0 | False | None | None | False | None | False | 7080.0 | 0 | 3609529 | 131235 | None | Market Rate | Supplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6844.0 | 6844.0 | 9.0 | False | None | None | False | None | False | 61596.0 | 0 | 3609530 | 131235 | None | Market Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2183.0 | 2183.0 | 9.0 | False | None | None | False | None | False | 19647.0 | 0 | 3609531 | 131235 | None | Market Rate | Supplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 767.0 | 767.0 | 95.0 | False | None | None | False | None | False | 72865.0 | 0 | 3609532 | 131235 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
a) 65mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4130.0 | 4130.0 | 2.0 | False | None | None | False | None | False | 8260.0 | 0 | 3609533 | 131235 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
b) 50mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3304.0 | 3304.0 | 4.0 | False | None | None | False | None | False | 13216.0 | 0 | 3609534 | 131235 | None | V2 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Unit | 345.68 | 345.68 | 4.0 | False | None | None | False | None | False | 1382.72 | 0 | 3609535 | 131235 | None | V2 9.29 | Providing and laying flooring and steps fine dressed granite stone slabs
40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with
cement mortar 1:3 over existing cement concrete bed , including cost
of materials, mortar, labour, curing complete as per specifications."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 5335.13 | 5335.13 | 18.0 | False | None | None | False | None | False | 96032.34 | 0 | 3609536 | 131235 | None | V2 10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded
and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti
tions by cutting a chase of appropriate width with chase cutter and embed
ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3455.57 | 3455.57 | 10.0 | False | None | None | False | None | False | 34555.7 | 0 | 3609537 | 131235 | None | V2 13.28 | Providing and fixing PTMT extension nipple for water tank pipe, fittings
of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 79.3 | 79.3 | 70.0 | False | None | None | False | None | False | 5551.0 | 0 | 3609538 | 131235 | None | 14.36.1 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of
approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g
"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 111.51 | 111.51 | 23.0 | False | None | None | False | None | False | 2564.73 | 0 | 3609539 | 131235 | None | 14.37.1 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective
length of tail pipe 260 mm from the centre of the waste coupling, 77 mm
breadth with 25 mm minimum water seal, weighing not less than 260 g"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Unit | 379.13 | 379.13 | 23.0 | False | None | None | False | None | False | 8719.99 | 0 | 3609540 | 131235 | None | 13.8.1.1 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 102.84 | 102.84 | 23.0 | False | None | None | False | None | False | 2365.32 | 0 | 3609541 | 131235 | None | 14.22.A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1003.59 | 1003.59 | 23.0 | False | None | None | False | None | False | 23082.57 | 0 | 3609542 | 131235 | None | 13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 768.18 | 768.18 | 53.0 | False | None | None | False | None | False | 40713.54 | 0 | 3609543 | 131235 | None | V2 14.63A | Providing and fixing Single lever sink mixer with swivel spout top
outlet wall mountable made of Stainless steel with all concealed fitting
arrangements & all necessary accesories complete - Class Economy "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4667.31 | 4667.31 | 4.0 | False | None | None | False | None | False | 18669.24 | 0 | 3609544 | 131235 | None | 14.4.1 | Providing and fixing white vitreous china flat back or wall corner type
lipped front urinal basin of 430x260x350 mm and 340x410x265 mm
sizes respectively with automatic flushing cistern with standard flush
pipe and C.P. brass spreaders with brass unions and G.I clamps complete,
including painting of fittings and brackets, cutting and making good the
walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 5518.51 | 5518.51 | 4.0 | False | None | None | False | None | False | 22074.04 | 0 | 3609545 | 131235 | None | ELE 7.3 | Supplying, installation, testing and commissioning of solar hot water
heater comprising of solar Flat Plate Collector (FPC) of size
2120x1040x100mm and stainless steel hot water storage tank with
stainless steel heat exchanger absorber made of copper sheet and
copper tube of following capacity aluminium box collector with
appropriate capacity electrical back up arrangement excluding inlet
and out let pipes. SS Model with 100mm thick of 48Kg/M3 density
Rock wool insulation with 22SWG Aluminium cladding."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 39372.94 | 39372.94 | 3.0 | False | None | None | False | None | False | 118118.82 | 0 | 3609546 | 131235 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-110mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 944.0 | 944.0 | 10.0 | False | None | None | False | None | False | 9440.0 | 0 | 3609547 | 131235 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-75mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 767.0 | 767.0 | 2.0 | False | None | None | False | None | False | 1534.0 | 0 | 3609548 | 131235 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-160MM dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1298.0 | 1298.0 | 1.0 | False | None | None | False | None | False | 1298.0 | 0 | 3609549 | 131235 | None | V-1,P.NO 6,IT.NO 1.4.1 | Earth work excavation by manual means for drains,canals, waste weir,
draft, approach channels, key trenches, foundation of bridges and
such simillar works in all kinds of soils , as per drawing and technical
specifications, including setting out, shoring, strutting, barricading,
caution lights, removal of stumps and other deleterious matter,
excavated surface leveled and sides neatly dressed disposing off the
excavated stuff or sorting & stacking the selected stuff for reuse in a
radius of 50 m and lift upto 1.5 m including cost of labour, tools & other
appurtenaces required to complete the work."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 299.84 | 299.84 | 224.0 | False | None | None | False | None | False | 67164.16 | 0 | 3609550 | 131235 | None | V-1 P.NO 7 IT.NO 1.11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 536.49 | 536.49 | 224.0 | False | None | None | False | None | False | 120173.76 | 0 | 3609551 | 131235 | None | V-5 P.NO 134 IT.NO 10.3 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013
with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of
elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing
the pipes alround to a depth of not less than 15 cms. with soft gravel
or selected earth available from the excavation etc. complete and giving
necessary hydraulic test to the required pressure as per ISS (contractor
will make his own arrangements for procuring water for testing) etc.
complete. for:"
Pipes of SN8 Self Fit - 160mm dia.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 764.46 | 764.46 | 300.0 | False | None | None | False | None | False | 229338.0 | 0 | 3609552 | 131235 | None | V-5 P.NO 134 IT.NO 10.2.4 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ).
- do - 160 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 713.66 | 713.66 | 70.0 | False | None | None | False | None | False | 49956.2 | 0 | 3609553 | 131235 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6757.51 | 6757.51 | 45.0 | False | None | None | False | None | False | 304087.95 | 0 | 3609554 | 131235 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6757.51 | 6757.51 | 15.0 | False | None | None | False | None | False | 101362.65 | 0 | 3609555 | 131235 | None | 13.39 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete
with C.I. grating brick masonry chamber 150 x 100 mm size P type With
Non Modular common burnt clay bricks of designation 3.5 & with water
tight C.I. cover with frame of 300 x300 mm size (inside) the weight of
cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as
per standard design:"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3197.86 | 3197.86 | 25.0 | False | None | None | False | None | False | 79946.5 | 0 | 3609556 | 131235 | None | 16.18 | Construction of RCC Machinehole chambers of 1:1.5:3 proportion
or approved type Cast-insitu / Pre-cast RCC Machinehole chambers,
constructed using form vibrators of standard type, with barricading,
danger lighting and using of sight rails and boning rods wherever
necessary, shoring and strutting wherever required using Ordinary
Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down
graded jelly, well graded sand and steel of approved quality, 200 mm
thick top concrete slab, having wall thickness and raft thickness as in
approved drawings and with an offset in raft alround the chamber as
in approved drawing, benching concrete with 1:6 slope towards the
central drain finished smooth, including fixing and grouting of pipes,
including conveying to work spot supply and fixing SFRC Machinehole
cover and frame (Heavy duty) conforming to IS:12592 with latest
amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3
mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia.
Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as
detailed in Technical specifications, including stone grit beding wherever
required, watering, curing, engraving Machinehole number with flow
direction on the inner cylindrical surface etc., complete including
cost of reinforcement steel and fabrication charges and also cost and
conveyance of all materials, labour with all lead and lifts. The Pre-cast
RCC Machinehole are for various diamters and depths as stated below
and as per detailed drawings, specifications and direction of the Engineer.
For 1.2m dia Machinehole:"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 97246.63 | 97246.63 | 1.0 | False | None | None | False | None | False | 97246.63 | 0 | 3609557 | 131235 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
External & Shafts & Terrace
40mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 80.0 | False | None | None | False | None | False | 47280.0 | 0 | 3609558 | 131235 | None | 13.23 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g)
T.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1665.22 | 1665.22 | 5.0 | False | None | None | False | None | False | 8326.1 | 0 | 3609559 | 131235 | None | 13.40.1 V-5 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 19340.79 | 19340.79 | 2.0 | False | None | None | False | None | False | 38681.58 | 0 | 3609560 | 131235 | None | 13.32 V-5 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and
equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 8053.5 | 8053.5 | 2.0 | False | None | None | False | None | False | 16107.0 | 0 |
| 1721828233000 | 0 | None | None | Buildings | MUDABULL ELECTRICAL WORKS | 4364380.98 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3609561 | 131236 | None | PWD ELE SR V-6 IT.NO 2.2.1 | WIRES & CABLES
Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Short point up to 3Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 333.29 | 333.29 | 25.0 | False | None | None | False | None | False | 8332.25 | 0 | 3609562 | 131236 | None | PWD ELE SR V-10 IT.NO 2.2.2 | Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Pack | 469.58 | 469.58 | 36.0 | False | None | None | False | None | False | 16904.88 | 0 | 3609563 | 131236 | None | PWD ELE SR V-11 IT.NO 2.2.3 | Point wiring using Copper wire without switch.
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Long point above 6Mtr up to 10Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 687.65 | 687.65 | 63.0 | False | None | None | False | None | False | 43321.95 | 0 | 3609564 | 131236 | None | PWD ELE SR V-12 IT.NO 2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 838.8 | 838.8 | 8.0 | False | None | None | False | None | False | 6710.4 | 0 | 3609565 | 131236 | None | PWD ELE SR V-14 IT.NO 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
1-3Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 170.98 | 170.98 | 25.0 | False | None | None | False | None | False | 4274.5 | 0 | 3609566 | 131236 | None | PWD ELE SR V-15 IT.NO 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
4-5Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 197.0 | 197.0 | 32.0 | False | None | None | False | None | False | 6304.0 | 0 | 3609567 | 131236 | None | PWD ELE SR V-16 IT.NO 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
6Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 219.3 | 219.3 | 16.0 | False | None | None | False | None | False | 3508.8 | 0 | 3609568 | 131236 | None | PWD ELE SR V-17 IT.NO 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
8 Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 272.58 | 272.58 | 7.0 | False | None | None | False | None | False | 1908.06 | 0 | 3609569 | 131236 | None | PWD ELE SR V-18 IT.NO 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
10-12Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 323.38 | 323.38 | 20.0 | False | None | None | False | None | False | 6467.6 | 0 | 3609570 | 131236 | None | PWD ELE SR V-20 IT.NO 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
1 to 3 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 199.48 | 199.48 | 32.0 | False | None | None | False | None | False | 6383.36 | 0 | 3609571 | 131236 | None | PWD ELE SR V-21 IT.NO 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
4 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 216.83 | 216.83 | 16.0 | False | None | None | False | None | False | 3469.28 | 0 | 3609572 | 131236 | None | PWD ELE SR V-22 IT.NO 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
6 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 289.93 | 289.93 | 7.0 | False | None | None | False | None | False | 2029.51 | 0 | 3609573 | 131236 | None | PWD ELE SR V-23 IT.NO 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
8 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 351.88 | 351.88 | 21.0 | False | None | None | False | None | False | 7389.48 | 0 | 3609574 | 131236 | None | PWD ELE SR V-24 IT.NO 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
10-12 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 426.22 | 426.22 | 31.0 | False | None | None | False | None | False | 13212.82 | 0 | 3609575 | 131236 | None | PWD ELE SR V-26 IT.NO 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps one way Switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 126.38 | 126.38 | 217.0 | False | None | None | False | None | False | 27424.46 | 0 | 3609576 | 131236 | None | PWD ELE SR V-6 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps Two way Switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 205.67 | 205.67 | 2.0 | False | None | None | False | None | False | 411.34 | 0 | 3609577 | 131236 | None | PWD ELE SR V-6,IT.NO 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps 3way socket
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 211.87 | 211.87 | 81.0 | False | None | None | False | None | False | 17161.47 | 0 | 3609578 | 131236 | None | PWD ELE SR V-6,IT.NO 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Stepped Fan Regulator.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 442.32 | 442.32 | 24.0 | False | None | None | False | None | False | 10615.68 | 0 | 3609579 | 131236 | None | PWD ELE SR V-6,IT.NO 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
16Amps one way switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 223.02 | 223.02 | 10.0 | False | None | None | False | None | False | 2230.2 | 0 | 3609580 | 131236 | None | PWD ELE SR V-6, IT.NO 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
32Amps DP switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 403.91 | 403.91 | 15.0 | False | None | None | False | None | False | 6058.65 | 0 | 3609581 | 131236 | None | PWD ELE SR V-6,IT.NO 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6/16Amps universal socket
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 292.4 | 292.4 | 25.0 | False | None | None | False | None | False | 7310.0 | 0 | 3609582 | 131236 | None | PWD ELE SR V-6,IT.NO 1.13 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Supplyin and Fixing Metal Fan Box with Round Hook.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 144.96 | 144.96 | 24.0 | False | None | None | False | None | False | 3479.04 | 0 | 3609583 | 131236 | None | PWD ELE SR V-6,IT.NO-1.2.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
19/20mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 81.77 | 81.77 | 890.0 | False | None | None | False | None | False | 72775.3 | 0 | 3609584 | 131236 | None | PWD ELE SR V-6,IT.NO 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
25mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 96.64 | 96.64 | 1030.0 | False | None | None | False | None | False | 99539.2 | 0 | 3609585 | 131236 | None | PWD ELE SR V-6, IT.NO .2.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
32mm dia 2.5mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 127.62 | 127.62 | 250.0 | False | None | None | False | None | False | 31905.0 | 0 | 3609586 | 131236 | None | PWD ELE SR V-6,IT.NO1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
19/20mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 84.25 | 84.25 | 445.0 | False | None | None | False | None | False | 37491.25 | 0 | 3609587 | 131236 | None | PWD ELE SR V-6,IT.NO-1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 97.88 | 97.88 | 515.0 | False | None | None | False | None | False | 50408.2 | 0 | 3609588 | 131236 | None | PWD ELE SR V-6,IT.NO-1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
32mm dia 2.5mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 122.66 | 122.66 | 150.0 | False | None | None | False | None | False | 18399.0 | 0 | 3609589 | 131236 | None | PWD ELE SR V-6,IT.NO 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 32.21 | 32.21 | 470.0 | False | None | None | False | None | False | 15138.7 | 0 | 3609590 | 131236 | None | PWD ELE SR V-6,IT.NO 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 52.04 | 52.04 | 1530.0 | False | None | None | False | None | False | 79621.2 | 0 | 3609591 | 131236 | None | PWD ELE SR V-6,IT.NO 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
4 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 78.06 | 78.06 | 740.0 | False | None | None | False | None | False | 57764.4 | 0 | 3609592 | 131236 | None | PWD ELE SR V-6,IT.NO 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
6 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 113.99 | 113.99 | 580.0 | False | None | None | False | None | False | 66114.2 | 0 | 3609593 | 131236 | None | PWD ELE SR V-6,IT.NO 5.19.11 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure
III - Double Door
4 Way TP & N
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 5003.08 | 5003.08 | 2.0 | False | None | None | False | None | False | 10006.16 | 0 | 3609594 | 131236 | None | PWD ELE SR V-6,IT.NO 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
6-32Amps SP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 514.19 | 514.19 | 62.0 | False | None | None | False | None | False | 31879.78 | 0 | 3609595 | 131236 | None | PWD ELE SR V-6 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
40Amps TPN
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3771.52 | 3771.52 | 2.0 | False | None | None | False | None | False | 7543.04 | 0 | 3609596 | 131236 | None | PWD ELE SR V-6,IT.NO 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board
16-25 Amps 2 pole
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 5299.2 | 5299.2 | 2.0 | False | None | None | False | None | False | 10598.4 | 0 | 3609597 | 131236 | None | PWD ELE SR V-6,IT.NO 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only)
32mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 480.73 | 480.73 | 10.0 | False | None | None | False | None | False | 4807.3 | 0 | 3609598 | 131236 | None | PWD ELE SR V-6,IT.NO 6.17.8 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.
35 sqmm Long Barrel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 39.65 | 39.65 | 16.0 | False | None | None | False | None | False | 634.4 | 0 | 3609599 | 131236 | None | V-6 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4348.89 | 4348.89 | 7.0 | False | None | None | False | None | False | 30442.23 | 0 | 3609600 | 131236 | None | V-6 12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x3mm GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 101.6 | 101.6 | 100.0 | False | None | None | False | None | False | 10160.0 | 0 | 3609601 | 131236 | None | 12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
600X600X3 GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1084.13 | 1084.13 | 6.0 | False | None | None | False | None | False | 6504.78 | 0 | 3609602 | 131236 | None | 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1096.52 | 1096.52 | 19.0 | False | None | None | False | None | False | 20833.88 | 0 | 3609603 | 131236 | None | 11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1640.44 | 1640.44 | 5.0 | False | None | None | False | None | False | 8202.2 | 0 | 3609604 | 131236 | None | 11.3.2 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 854.91 | 854.91 | 51.0 | False | None | None | False | None | False | 43600.41 | 0 | 3609605 | 131236 | None | 11.11.3 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 184.61 | 184.61 | 15.0 | False | None | None | False | None | False | 2769.15 | 0 | 3609606 | 131236 | None | PWD ELE SR V-6,IT.NO 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1848.59 | 1848.59 | 13.0 | False | None | None | False | None | False | 24031.67 | 0 | 3609607 | 131236 | None | PWD ELE SR V-6,IT.NO 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3316.8 | 3316.8 | 24.0 | False | None | None | False | None | False | 79603.2 | 0 | 3609608 | 131236 | None | PWD ELE SR V-6,IT.NO 13.11 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.
On wall / ceiling / Rafter / Girders
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 390.29 | 390.29 | 24.0 | False | None | None | False | None | False | 9366.96 | 0 | 3609609 | 131236 | None | PWD ELE SR V-6,IT.NO 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 151.16 | 151.16 | 83.0 | False | None | None | False | None | False | 12546.28 | 0 | 3609610 | 131236 | None | PWD ELE SR V-6,IT.NO 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 875.97 | 875.97 | 13.0 | False | None | None | False | None | False | 11387.61 | 0 | 3609611 | 131236 | None | PWD ELE SR V-6,IT.NO 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 200.72 | 200.72 | 3.0 | False | None | None | False | None | False | 602.16 | 0 | 3609612 | 131236 | None | PWD ELE SR V-6,IT.NO 5.42.1 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete
16SWG
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 86000.0 | False | None | None | False | None | False | 45580.0 | 0 | 3609613 | 131236 | None | PWD ELE SR V-6,IT.NO 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 4255.97 | 4255.97 | 5.0 | False | None | None | False | None | False | 21279.85 | 0 | 3609614 | 131236 | None | PWD ELE SR V-6,IT.NO 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
40x40x6mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 377.9 | 377.9 | 10.0 | False | None | None | False | None | False | 3779.0 | 0 | 3609615 | 131236 | None | PWD ELE SR V-6,IT.NO 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
50x100x50x6mm C channel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 936.68 | 936.68 | 10.0 | False | None | None | False | None | False | 9366.8 | 0 | 3609616 | 131236 | None | PWD ELE SR V-6,IT.NO 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs)
100Amps 25kA
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 10515.39 | 10515.39 | 1.0 | False | None | None | False | None | False | 10515.39 | 0 | 3609617 | 131236 | None | PWD ELE SR V-6,iT.NO 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
50-63Amps DP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3826.03 | 3826.03 | 10.0 | False | None | None | False | None | False | 38260.3 | 0 | 3609618 | 131236 | None | PWD ELE SR V-6,IT.NO 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 11541.29 | 11541.29 | 1.0 | False | None | None | False | None | False | 11541.29 | 0 | 3609619 | 131236 | None | PWD ELE SR V-6,IT.NO 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3609620 | 131236 | None | PWD ELE SR V-6,IT.NO 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 696.32 | 696.32 | 3.0 | False | None | None | False | None | False | 2088.96 | 0 | 3609621 | 131236 | None | PWD ELE SR V-6,IT.NO5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kvar | 594.72 | 594.72 | 15.0 | False | None | None | False | None | False | 8920.8 | 0 | 3609622 | 131236 | None | 5.19.9 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2885.63 | 2885.63 | 2.0 | False | None | None | False | None | False | 5771.26 | 0 | 3609623 | 131236 | None | 5.19.12 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6120.66 | 6120.66 | 1.0 | False | None | None | False | None | False | 6120.66 | 0 | 3609624 | 131236 | None | 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3826.03 | 3826.03 | 1.0 | False | None | None | False | None | False | 3826.03 | 0 | 3609625 | 131236 | None | 5.20.8 | Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6377.13 | 6377.13 | 3.0 | False | None | None | False | None | False | 19131.39 | 0 | 3609626 | 131236 | None | 32.05 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 109549.9 | 109549.9 | 0.1 | False | None | None | False | None | False | 10954.99 | 0 | 3609627 | 131236 | None | 32.09 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 190882.82 | 190882.82 | 0.05 | False | None | None | False | None | False | 9544.141 | 0 | 3609628 | 131236 | None | 32.13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 393892.97 | 393892.97 | 0.1 | False | None | None | False | None | False | 39389.297 | 0 | 3609629 | 131236 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 25877.75 | 25877.75 | 0.05 | False | None | None | False | None | False | 1293.8875 | 0 | 3609630 | 131236 | None | 31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 38581.22 | 38581.22 | 0.2 | False | None | None | False | None | False | 7716.244 | 0 | 3609631 | 131236 | None | 6.17.6 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 15.41 | 15.41 | 20.0 | False | None | None | False | None | False | 308.2 | 0 | 3609632 | 131236 | None | 16.17.10 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 148.68 | 148.68 | 16.0 | False | None | None | False | None | False | 2378.88 | 0 | 3609633 | 131236 | None | 11.11.5 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 333.29 | 333.29 | 9.0 | False | None | None | False | None | False | 2999.61 | 0 | 3609634 | 131236 | None | 11.6.3 | Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 5641.17 | 5641.17 | 8.0 | False | None | None | False | None | False | 45129.36 | 0 | 3609635 | 131236 | None | 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4985.74 | 4985.74 | 2.0 | False | None | None | False | None | False | 9971.48 | 0 | 3609636 | 131236 | None | 13.4.1 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1810.18 | 1810.18 | 3.0 | False | None | None | False | None | False | 5430.54 | 0 | 3609637 | 131236 | None | 5.14.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 2738.19 | 2738.19 | 2.0 | False | None | None | False | None | False | 5476.38 | 0 | 3609638 | 131236 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 169.74 | 169.74 | 24.0 | False | None | None | False | None | False | 4073.76 | 0 | 3609639 | 131236 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 395.24 | 395.24 | 31.0 | False | None | None | False | None | False | 12252.44 | 0 | 3609640 | 131236 | None | 2.2.5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 1225.37 | 1225.37 | 4.0 | False | None | None | False | None | False | 4901.48 | 0 | 3609641 | 131236 | None | 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 144.96 | 144.96 | 6.0 | False | None | None | False | None | False | 869.76 | 0 | 3609642 | 131236 | None | 12.46 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 78.06 | 78.06 | 21.0 | False | None | None | False | None | False | 1639.26 | 0 | 3609643 | 131236 | None | 3.6.11 | TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 193.28 | 193.28 | 2.0 | False | None | None | False | None | False | 386.56 | 0 | 3609644 | 131236 | None | 12.2.1 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 304.79 | 304.79 | 1.0 | False | None | None | False | None | False | 304.79 | 0 | 3609645 | 131236 | None | 32.02 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 98168.45 | 98168.45 | 0.1 | False | None | None | False | None | False | 9816.845 | 0 | 3609646 | 131236 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 25877.75 | 25877.75 | 0.1 | False | None | None | False | None | False | 2587.775 | 0 | 3609647 | 131236 | None | pwd sr | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 15.41 | 15.41 | 15.0 | False | None | None | False | None | False | 231.15 | 0 | 3609648 | 131236 | None | 11..11.7 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 527.81 | 527.81 | 3.0 | False | None | None | False | None | False | 1583.43 | 0 | 3609649 | 131236 | None | 12.27 | Supplying & Fixing of Special Type pigmy and candle lamp.
Operating voltage range from 180V to 265V, 50Hz AC power Supply"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 64.43 | 64.43 | 2.0 | False | None | None | False | None | False | 128.86 | 0 | 3609650 | 131236 | None | 11.8.1 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3004.58 | 3004.58 | 1.0 | False | None | None | False | None | False | 3004.58 | 0 | 3609651 | 131236 | None | 5.7.2 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 298.6 | 298.6 | 1.0 | False | None | None | False | None | False | 298.6 | 0 | 3609652 | 131236 | None | 5.30 | Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1709.82 | 1709.82 | 1.0 | False | None | None | False | None | False | 1709.82 | 0 | 3609653 | 131236 | None | 7.1.3 | Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 12689.84 | 12689.84 | 1.0 | False | None | None | False | None | False | 12689.84 | 0 | 3609654 | 131236 | None | PWD SR 2023-24 Volume 6 It No-9.3.3 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 84726.54 | 84726.54 | 1.0 | False | None | None | False | None | False | 84726.54 | 0 | 3609655 | 131236 | None | PWD SR 2023-24 Volume 6 It No-9.5.9 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 19693.91 | 19693.91 | 4.0 | False | None | None | False | None | False | 78775.64 | 0 | 3609656 | 131236 | None | A.R | Item Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 300000.0 | 300000.0 | 1.0 | False | None | None | False | None | False | 300000.0 | 0 | 3609657 | 131236 | None | LQR | IP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 23836.0 | 23836.0 | 4.0 | False | None | None | False | None | False | 95344.0 | 0 | 3609658 | 131236 | None | LQR | IP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 25606.0 | 25606.0 | 2.0 | False | None | None | False | None | False | 51212.0 | 0 | 3609659 | 131236 | None | LQR | Supplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3609660 | 131236 | None | LQR | Supply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 17110.0 | 17110.0 | 2.0 | False | None | None | False | None | False | 34220.0 | 0 | 3609661 | 131236 | None | LQR | Supply and Installation of I/Os
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 147.5 | 147.5 | 12.0 | False | None | None | False | None | False | 1770.0 | 0 | 3609662 | 131236 | None | LQR | Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 265.5 | 265.5 | 12.0 | False | None | None | False | None | False | 3186.0 | 0 | 3609663 | 131236 | None | LQR | Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 336.3 | 336.3 | 6.0 | False | None | None | False | None | False | 2017.8 | 0 | 3609664 | 131236 | None | LQR | Supply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3609665 | 131236 | None | V-6 8.1 | Supplying and drawing UTP-CAT 6E LAN cable
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 47.08 | 47.08 | 600.0 | False | None | None | False | None | False | 28248.0 | 0 | 3609666 | 131236 | None | 1.2.2 | Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 96.64 | 96.64 | 500.0 | False | None | None | False | None | False | 48320.0 | 0 | 3609667 | 131236 | None | 8.12.3 | Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3778.95 | 3778.95 | 1.0 | False | None | None | False | None | False | 3778.95 | 0 | 3609668 | 131236 | None | 8.4.1 v-6 | Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 6061.19 | 6061.19 | 1.0 | False | None | None | False | None | False | 6061.19 | 0 | 3609669 | 131236 | None | 1.01 | Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 8767.16 | 8767.16 | 8.0 | False | None | None | False | None | False | 70137.28 | 0 | 3609670 | 131236 | None | 2.02 | Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 1379.01 | 1379.01 | 8.0 | False | None | None | False | None | False | 11032.08 | 0 | 3609671 | 131236 | None | 6.05 | Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 107.79 | 107.79 | 6.0 | False | None | None | False | None | False | 646.74 | 0 | 3609672 | 131236 | None | 13.12 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 59.47 | 59.47 | 6.0 | False | None | None | False | None | False | 356.82 | 0 | 3609673 | 131236 | None | 2.16 | Supply of Spiral Earth Electrode
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 296.12 | 296.12 | 11.0 | False | None | None | False | None | False | 3257.32 | 0 | 3609674 | 131236 | None | 2.16 | Erection of Spiral Earth Electrode
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 115.23 | 115.23 | 11.0 | False | None | None | False | None | False | 1267.53 | 0 | 3609675 | 131236 | None | 68.17 | Supply and fixing of Caution/Danger Board
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 185.85 | 185.85 | 6.0 | False | None | None | False | None | False | 1115.1 | 0 | 3609676 | 131236 | None | 4.02 | Supply of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 110.27 | 110.27 | 8.0 | False | None | None | False | None | False | 882.16 | 0 | 3609677 | 131236 | None | 5.09 | Erection of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 52.04 | 52.04 | 8.0 | False | None | None | False | None | False | 416.32 | 0 | 3609678 | 131236 | None | 24.05 | Supply and fixing of 11 kV, 400 Amps Double Break GOS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 26341.14 | 26341.14 | 1.0 | False | None | None | False | None | False | 26341.14 | 0 | 3609679 | 131236 | None | 24.07 | Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 7521.97 | 7521.97 | 1.0 | False | None | None | False | None | False | 7521.97 | 0 | 3609680 | 131236 | None | 25.01 | Supply of DOLO Cut Out
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set of 3 Nos | 7279.13 | 7279.13 | 1.0 | False | None | None | False | None | False | 7279.13 | 0 | 3609681 | 131236 | None | 13.01 | Erection of DOLO Cut Out
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set of 3 Nos | 293.64 | 293.64 | 1.0 | False | None | None | False | None | False | 293.64 | 0 | 3609682 | 131236 | None | 13.07 | Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 210958.34 | 210958.34 | 1.0 | False | None | None | False | None | False | 210958.34 | 0 | 3609683 | 131236 | None | 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 4348.89 | 4348.89 | 8.0 | False | None | None | False | None | False | 34791.12 | 0 | 3609684 | 131236 | None | 12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | MT | 158.59 | 158.59 | 100.0 | False | None | None | False | None | False | 15859.0 | 0 | 3609685 | 131236 | None | 12.58.9 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 2035.68 | 2035.68 | 100.0 | False | None | None | False | None | False | 203568.0 | 0 | 3609686 | 131236 | None | 12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 9194.62 | 9194.62 | 10.0 | False | None | None | False | None | False | 91946.2 | 0 | 3609687 | 131236 | None | 45.07 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 5039.01 | 5039.01 | 4.0 | False | None | None | False | None | False | 20156.04 | 0 | 3609688 | 131236 | None | 45.04 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 3887.98 | 3887.98 | 2.0 | False | None | None | False | None | False | 7775.96 | 0 | 3609689 | 131236 | None | 36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 1102296.17 | 1102296.17 | 0.1 | False | None | None | False | None | False | 110229.617 | 0 | 3609690 | 131236 | None | 38. | Providing chain link fencing 50 mm size of 8 guage properly stretched between
rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be
welded to the Pole and block pipe at top and bottom as required including cost
of all materials, labour, lead and lifts, cutting, bending wherever necessary,
wastage and lapping etc., complete as per the direction of the engineer
incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1222.89 | 1222.89 | 150.0 | False | None | None | False | None | False | 183433.5 | 0 | 3609691 | 131236 | None | 5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 176000.0 | False | None | None | False | None | False | 93280.0 | 0 | 3609692 | 131236 | None | 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 4255.97 | 4255.97 | 6.0 | False | None | None | False | None | False | 25535.82 | 0 | 3609693 | 131236 | None | 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 377.9 | 377.9 | 12.0 | False | None | None | False | None | False | 4534.8 | 0 | 3609694 | 131236 | None | 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 936.68 | 936.68 | 12.0 | False | None | None | False | None | False | 11240.16 | 0 | 3609695 | 131236 | None | 5.15.15 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 29172.26 | 29172.26 | 1.0 | False | None | None | False | None | False | 29172.26 | 0 | 3609696 | 131236 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3609697 | 131236 | None | 10.1.3 | Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have +
1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating
lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting
battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr
at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 558914.14 | 558914.14 | 1.0 | False | None | None | False | None | False | 558914.14 | 0 | 3609698 | 131236 | None | 10.2.2 | Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the
accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 72742.93 | 72742.93 | 1.0 | False | None | None | False | None | False | 72742.93 | 0 | 3609699 | 131236 | None | A.R | Supply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 3540.0 | 3540.0 | 5.0 | False | None | None | False | None | False | 17700.0 | 0 | 3609700 | 131236 | None | A.R | Supply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 236.0 | 236.0 | 50.0 | False | None | None | False | None | False | 11800.0 | 0 | 3609701 | 131236 | None | 58.02 | LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 98973.8 | 98973.8 | 1.0 | False | None | None | False | None | False | 98973.8 | 0 | 3609702 | 131236 | None | 53.01 | CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 24302.99 | 24302.99 | 1.0 | False | None | None | False | None | False | 24302.99 | 0 | 3609703 | 131236 | None | 10.01 | Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 173.46 | 173.46 | 15.0 | False | None | None | False | None | False | 2601.9 | 0 | 3609704 | 131236 | None | v-6 2.02 | Supply of 11 kV, Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr
Long, 145 Kg WL"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 603.39 | 603.39 | 6.0 | False | None | None | False | None | False | 3620.34 | 0 | 3609705 | 131236 | None | v-6 2.02 | Erection of 11 kV, Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr
Long, 145 Kg WL"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 318.42 | 318.42 | 6.0 | False | None | None | False | None | False | 1910.52 | 0 | 3609706 | 131236 | None | v-6 6.06 | Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP
Rod) "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 254.0 | 254.0 | 18.0 | False | None | None | False | None | False | 4572.0 | 0 | 3609707 | 131236 | None | v-6 6.10 | Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 235.45 | 235.45 | 18.0 | False | None | None | False | None | False | 4238.1 | 0 | 3609708 | 131236 | None | 13.12 v-6 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 59.47 | 59.47 | 18.0 | False | None | None | False | None | False | 1070.46 | 0 | 3609709 | 131236 | None | v-6 6.08 | Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 73.1 | 73.1 | 4.0 | False | None | None | False | None | False | 292.4 | 0 | 3609710 | 131236 | None | 7.02 | Supply of Rabbit ACSR Conductor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 57283.93 | 57283.93 | 1.0 | False | None | None | False | None | False | 57283.93 | 0 | 3609711 | 131236 | None | 6.02 V-6 | Erection of Rabbit ACSR Conductor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 5403.28 | 5403.28 | 1.0 | False | None | None | False | None | False | 5403.28 | 0 |
| 1721828233000 | 0 | None | None | Buildings | MALAGATHI IN SHORAPUR TALUK | 34741282.93 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3609712 | 131237 | None | CSR:V-3 PAGE NO 9 Itm 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | 100 Sqm | 486.93 | 486.93 | 17.49 | False | None | None | False | None | False | 8516.4057 | 0 | 3609713 | 131237 | None | V-1 page 8 itm 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 117.71 | 117.71 | 768.64 | False | None | None | False | None | False | 90476.6144 | 0 | 3609714 | 131237 | None | V-1page 8 itm 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 126.38 | 126.38 | 1311.57 | False | None | None | False | None | False | 165756.2166 | 0 | 3609715 | 131237 | None | V-1page 8 itm 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 449.76 | 449.76 | 230.53 | False | None | None | False | None | False | 103683.1728 | 0 | 3609716 | 131237 | None | V-3page 3 A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 167.27 | 167.27 | 225.13 | False | None | None | False | None | False | 37657.4951 | 0 | 3609717 | 131237 | None | V-2page5 itm 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 146.2 | 146.2 | 774.16 | False | None | None | False | None | False | 113182.192 | 0 | 3609718 | 131237 | None | V-1pg7 itm1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 329.57 | 329.57 | 807.35 | False | None | None | False | None | False | 266078.3395 | 0 | 3609719 | 131237 | None | V-1page7vitm1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 587.29 | 587.29 | 728.89 | False | None | None | False | None | False | 428069.8081 | 0 | 3609720 | 131237 | None | V-1page 15 itm2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7420.37 | 7420.37 | 161.37 | False | None | None | False | None | False | 1197425.1069 | 0 | 3609721 | 131237 | None | V-1page15 itm 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8478.33 | 8478.33 | 177.95 | False | None | None | False | None | False | 1508718.8235 | 0 | 3609722 | 131237 | None | V-1page16 itm 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8635.33 | 8635.33 | 13.4 | False | None | None | False | None | False | 115713.422 | 0 | 3609723 | 131237 | None | V-1page15itm 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 14413.41 | 14413.41 | 55.14 | False | None | None | False | None | False | 794755.4274 | 0 | 3609724 | 131237 | None | V-3page135itm15.4 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 252.76 | 252.76 | 13.0 | False | None | None | False | None | False | 3285.88 | 0 | 3609725 | 131237 | None | V-2page55 itm 8.16.a | Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1533.88 | 1533.88 | 13.81 | False | None | None | False | None | False | 21182.8828 | 0 | 3609726 | 131237 | None | V-1page18itm2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Tonne | 110837.22 | 110837.22 | 50.82 | False | None | None | False | None | False | 5632747.5204 | 0 | 3609727 | 131237 | None | 18-19SR ITM4.21 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 38.94 | 38.94 | 145.02 | False | None | None | False | None | False | 5647.0788 | 0 | 3609728 | 131237 | None | DATA RATE | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 86.14 | 86.14 | 145.02 | False | None | None | False | None | False | 12492.0228 | 0 | 3609729 | 131237 | None | V-2PAGE 9 ITM5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7915.97 | 7915.97 | 8.76 | False | None | None | False | None | False | 69343.8972 | 0 | 3609730 | 131237 | None | V-2PAGE 14 ITM 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1623.09 | 1623.09 | 1313.93 | False | None | None | False | None | False | 2132626.6437 | 0 | 3609731 | 131237 | None | V-2page 14 itm 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks
of size 400x100x200mm having block density more than 1800kg/m3
and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005
including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1367.86 | 1367.86 | 171.24 | False | None | None | False | None | False | 234232.3464 | 0 | 3609732 | 131237 | None | V-2 page100 itm 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 122431.79 | 122431.79 | 1.2 | False | None | None | False | None | False | 146918.148 | 0 | 3609733 | 131237 | None | V-2 page 105 itm 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 1258.82 | 1258.82 | 32.0 | False | None | None | False | None | False | 40282.24 | 0 | 3609734 | 131237 | None | 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 681.45 | 681.45 | 64.0 | False | None | None | False | None | False | 43612.8 | 0 | 3609735 | 131237 | None | 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 464.63 | 464.63 | 32.0 | False | None | None | False | None | False | 14868.16 | 0 | 3609736 | 131237 | None | 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 185.85 | 185.85 | 64.0 | False | None | None | False | None | False | 11894.4 | 0 | 3609737 | 131237 | None | 22.15.9 | PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 86.73 | 86.73 | 128.0 | False | None | None | False | None | False | 11101.44 | 0 | 3609738 | 131237 | None | 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 123.9 | 123.9 | 32.0 | False | None | None | False | None | False | 3964.8 | 0 | 3609739 | 131237 | None | 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 1303.43 | 1303.43 | 32.0 | False | None | None | False | None | False | 41709.76 | 0 | 3609740 | 131237 | None | V-2page69 itm 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 74.34 | 74.34 | 192.0 | False | None | None | False | None | False | 14273.28 | 0 | 3609741 | 131237 | None | 20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 64.43 | 64.43 | 168.45 | False | None | None | False | None | False | 10853.2335 | 0 | 3609742 | 131237 | None | V-2page105 itm 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4115.96 | 4115.96 | 74.84 | False | None | None | False | None | False | 308038.4464 | 0 | 3609743 | 131237 | None | V-2page109 itm 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 8343.43 | 8343.43 | 69.39 | False | None | None | False | None | False | 578950.6077 | 0 | 3609744 | 131237 | None | V-2page109 itm 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 7085.84 | 7085.84 | 6.84 | False | None | None | False | None | False | 48467.1456 | 0 | 3609745 | 131237 | None | V-2page 86itm11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 208.15 | 208.15 | 1600.83 | False | None | None | False | None | False | 333212.7645 | 0 | 3609746 | 131237 | None | V-2page 111itm 12.93.1 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/
cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | m | 869.78 | 869.78 | 64.35 | False | None | None | False | None | False | 55970.343 | 0 | 3609747 | 131237 | None | V-2page84 itm 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kgs | 168.5 | 168.5 | 1724.91 | False | None | None | False | None | False | 290647.335 | 0 | 3609748 | 131237 | None | V-2page 41itm 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 386.57 | 386.57 | 1763.82 | False | None | None | False | None | False | 681839.8974 | 0 | 3609749 | 131237 | None | V-2page 43 itm 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 261.43 | 261.43 | 1176.83 | False | None | None | False | None | False | 307658.6669 | 0 | 3609750 | 131237 | None | V-2page50 itm 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 123.9 | 123.9 | 2919.03 | False | None | None | False | None | False | 361667.817 | 0 | 3609751 | 131237 | None | V-2page42itm 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 432.41 | 432.41 | 975.48 | False | None | None | False | None | False | 421807.3068 | 0 | 3609752 | 131237 | None | V-2page41 itm 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 438.61 | 438.61 | 163.05 | False | None | None | False | None | False | 71515.3605 | 0 | 3609753 | 131237 | None | 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 47.08 | 47.08 | 2013.85 | False | None | None | False | None | False | 94812.058 | 0 | 3609754 | 131237 | None | 10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 254.88 | 254.88 | 13.0 | False | None | None | False | None | False | 3313.44 | 0 | 3609755 | 131237 | None | V-2page 54itm 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 64.43 | 64.43 | 628.05 | False | None | None | False | None | False | 40465.2615 | 0 | 3609756 | 131237 | None | V-2page61itm 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1455.83 | 1455.83 | 580.89 | False | None | None | False | None | False | 845677.0887 | 0 | 3609757 | 131237 | None | V-2page59 itm9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 991.2 | 991.2 | 71.5 | False | None | None | False | None | False | 70870.8 | 0 | 3609758 | 131237 | None | V-2page63 itm 9.32 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3199.1 | 3199.1 | 34.54 | False | None | None | False | None | False | 110496.914 | 0 | 3609759 | 131237 | None | V-2page 4 itm 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 365.51 | 365.51 | 316.07 | False | None | None | False | None | False | 115526.7457 | 0 | 3609760 | 131237 | None | V-2page 60 itm 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1101.47 | 1101.47 | 59.14 | False | None | None | False | None | False | 65140.9358 | 0 | 3609761 | 131237 | None | V-2page65 itmv9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1795.31 | 1795.31 | 259.57 | False | None | None | False | None | False | 466008.6167 | 0 | 3609762 | 131237 | None | V-2 page85 itm11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 700.04 | 700.04 | 357.82 | False | None | None | False | None | False | 250488.3128 | 0 | 3609763 | 131237 | None | V-2 page 48itm 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 157.35 | 157.35 | 2741.14 | False | None | None | False | None | False | 431318.379 | 0 | 3609764 | 131237 | None | V-2page 46itm8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 193.28 | 193.28 | 759.66 | False | None | None | False | None | False | 146827.0848 | 0 | 3609765 | 131237 | None | V-2page47 itm8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 61.95 | 61.95 | 96.21 | False | None | None | False | None | False | 5960.2095 | 0 | 3609766 | 131237 | None | V-2page48 itm 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 142.49 | 142.49 | 76.23 | False | None | None | False | None | False | 10862.0127 | 0 | 3609767 | 131237 | None | V-2page47itm 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 65.67 | 65.67 | 179.6 | False | None | None | False | None | False | 11794.332 | 0 | 3609768 | 131237 | None | 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 838.8 | 838.8 | 179.6 | False | None | None | False | None | False | 150648.48 | 0 | 3609769 | 131237 | None | V-2page64itm 9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 2044.35 | 2044.35 | 17.32 | False | None | None | False | None | False | 35408.142 | 0 | 3609770 | 131237 | None | V-2page77 itm 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 5548.24 | 5548.24 | 5.25 | False | None | None | False | None | False | 29128.26 | 0 | 3609771 | 131237 | None | 15.12 | Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1443.44 | 1443.44 | 726.5 | False | None | None | False | None | False | 1048659.16 | 0 | 3609772 | 131237 | None | V-2PAGE22 ITM 7.17 | Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 411.35 | 411.35 | 24.74 | False | None | None | False | None | False | 10176.799 | 0 | 3609773 | 131237 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 102.35 | False | None | None | False | None | False | 1301658.642 | 0 | 3609774 | 131237 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 13565.56 | 13565.56 | 51.01 | False | None | None | False | None | False | 691979.2156 | 0 | 3609775 | 131237 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 115.4 | False | None | None | False | None | False | 1467624.888 | 0 | 3609776 | 131237 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 7.07 | False | None | None | False | None | False | 89914.2804 | 0 | 3609777 | 131237 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 13565.56 | 13565.56 | 12.12 | False | None | None | False | None | False | 164414.5872 | 0 | 3609778 | 131237 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 11911.13 | 11911.13 | 14.18 | False | None | None | False | None | False | 168899.8234 | 0 | 3609779 | 131237 | None | 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4317.92 | 4317.92 | 20.48 | False | None | None | False | None | False | 88431.0016 | 0 | 3609780 | 131237 | None | 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 141.25 | 141.25 | 36.0 | False | None | None | False | None | False | 5085.0 | 0 | 3609781 | 131237 | None | 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1642.91 | 1642.91 | 56.5 | False | None | None | False | None | False | 92824.415 | 0 | 3609782 | 131237 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 6601.39 | 6601.39 | 30.54 | False | None | None | False | None | False | 201606.4506 | 0 | 3609783 | 131237 | None | 10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4877.94 | 4877.94 | 9.69 | False | None | None | False | None | False | 47267.2386 | 0 | 3609784 | 131237 | None | 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 761.99 | 761.99 | 92.01 | False | None | None | False | None | False | 70110.6999 | 0 | 3609785 | 131237 | None | 8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 350.64 | 350.64 | 215.82 | False | None | None | False | None | False | 75675.1248 | 0 | 3609786 | 131237 | None | 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 360.55 | 360.55 | 68.92 | False | None | None | False | None | False | 24849.106 | 0 | 3609787 | 131237 | None | 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3533.63 | 3533.63 | 11.09 | False | None | None | False | None | False | 39187.9567 | 0 | 3609788 | 131237 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 6601.39 | 6601.39 | 13.73 | False | None | None | False | None | False | 90637.0847 | 0 | 3609789 | 131237 | None | 10.1.1 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4963.43 | 4963.43 | 3.81 | False | None | None | False | None | False | 18910.6683 | 0 | 3609790 | 131237 | None | 1.4.1 V-1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 299.84 | 299.84 | 11.06 | False | None | None | False | None | False | 3316.2304 | 0 | 3609791 | 131237 | None | 1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 320.9 | 320.9 | 1.7 | False | None | None | False | None | False | 545.53 | 0 | 3609792 | 131237 | None | 17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1391.4 | 1391.4 | 7.0 | False | None | None | False | None | False | 9739.8 | 0 | 3609793 | 131237 | None | 17.1 V-2 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1241.48 | 1241.48 | 0.28 | False | None | None | False | None | False | 347.6144 | 0 | 3609794 | 131237 | None | 17.2 V-2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1469.45 | 1469.45 | 0.14 | False | None | None | False | None | False | 205.723 | 0 | 3609795 | 131237 | None | 17. V-2 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1476.89 | 1476.89 | 0.14 | False | None | None | False | None | False | 206.7646 | 0 | 3609796 | 131237 | None | 17.4 V-2 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1659.02 | 1659.02 | 0.14 | False | None | None | False | None | False | 232.2628 | 0 | 3609797 | 131237 | None | 17.14 V-2 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1449.63 | 1449.63 | 1.0 | False | None | None | False | None | False | 1449.63 | 0 | 3609798 | 131237 | None | V3 305.3.4 | Compacting Original Ground
Compacting original ground supporting embankment
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 130.1 | 130.1 | 72.0 | False | None | None | False | None | False | 9367.2 | 0 | 3609799 | 131237 | None | V-3 4.2 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 2922.8 | 2922.8 | 36.0 | False | None | None | False | None | False | 105220.8 | 0 | 3609800 | 131237 | None | V3 6.1 ISSUE RATE | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 6095.88 | 6095.88 | 24.0 | False | None | None | False | None | False | 146301.12 | 0 | 3609801 | 131237 | None | V-3 6.2 ISSUE RATE | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 11107.64 | 11107.64 | 48.0 | False | None | None | False | None | False | 533166.72 | 0 | 3609802 | 131237 | None | V-3 8.10 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 105.32 | 105.32 | 15.0 | False | None | None | False | None | False | 1579.8 | 0 | 3609803 | 131237 | None | V-3 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 87.97 | 87.97 | 448.0 | False | None | None | False | None | False | 39410.56 | 0 | 3609804 | 131237 | None | V-314621A | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)
300 x 250 x 100 mm Kerb Stone
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 296.12 | 296.12 | 150.0 | False | None | None | False | None | False | 44418.0 | 0 | 3609805 | 131237 | None | 2.1.4 V-1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7702.86 | 7702.86 | 2.0 | False | None | None | False | None | False | 15405.72 | 0 | 3609806 | 131237 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 9156.76 | 9156.76 | 10.8 | False | None | None | False | None | False | 98893.008 | 0 | 3609807 | 131237 | None | 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 459.67 | 459.67 | 320.0 | False | None | None | False | None | False | 147094.4 | 0 | 3609808 | 131237 | None | 8.31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 220.54 | 220.54 | 320.0 | False | None | None | False | None | False | 70572.8 | 0 | 3609809 | 131237 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8761.09 | 8761.09 | 9.36 | False | None | None | False | None | False | 82003.8024 | 0 | 3609810 | 131237 | None | 8.20 V-3 | Providing and fixing 1.8 m high GI barbed wire fencing with
2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete,
0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 672.78 | 672.78 | 390.0 | False | None | None | False | None | False | 262384.2 | 0 | 3609811 | 131237 | None | V1 1.15.2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 526.58 | 526.58 | 22.51 | False | None | None | False | None | False | 11853.3158 | 0 | 3609812 | 131237 | None | 2.5.2 V1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8732.83 | 8732.83 | 4.32 | False | None | None | False | None | False | 37725.8256 | 0 | 3609813 | 131237 | None | 2.5.2 V1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 9326.32 | 9326.32 | 5.89 | False | None | None | False | None | False | 54932.0248 | 0 | 3609814 | 131237 | None | V2 15.14 | UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 2072.85 | 2072.85 | 36.6 | False | None | None | False | None | False | 75866.31 | 0 | 3609815 | 131237 | None | V5 18.3 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2430.92 | 2430.92 | 8.0 | False | None | None | False | None | False | 19447.36 | 0 | 3609816 | 131237 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 14413.41 | 14413.41 | 9.87 | False | None | None | False | None | False | 142260.3567 | 0 | 3609817 | 131237 | None | 15.5 V-2 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 749.6 | 749.6 | 63.57 | False | None | None | False | None | False | 47652.072 | 0 | 3609818 | 131237 | None | 8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 110.27 | 110.27 | 20.1 | False | None | None | False | None | False | 2216.427 | 0 | 3609819 | 131237 | None | V-5P140I12.4 | Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3609820 | 131237 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3609821 | 131237 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above 50 Mtrs and upto 100 Mtr
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3609822 | 131237 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above100 Mtrs. and upto 150 Mtr
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3609823 | 131237 | None | V-5P143I12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 2394.99 | 2394.99 | 20.0 | False | None | None | False | None | False | 47899.8 | 0 | 3609824 | 131237 | None | V-5P155I13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 681.45 | 681.45 | 150.0 | False | None | None | False | None | False | 102217.5 | 0 | 3609825 | 131237 | None | V-5P143I12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3609826 | 131237 | None | V-5P154I12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3609827 | 131237 | None | 18-19 SR13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3609828 | 131237 | None | V-5P154I13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.
5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 39817.74 | 39817.74 | 1.0 | False | None | None | False | None | False | 39817.74 | 0 | 3609829 | 131237 | None | V-5P155I13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3609830 | 131237 | None | V-5P155I13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3609831 | 131237 | None | V-5P155I13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3609832 | 131237 | None | V-5P156I13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3609833 | 131237 | None | V-5P156I13.33 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 1672.65 | 1672.65 | 1.0 | False | None | None | False | None | False | 1672.65 | 0 | 3609834 | 131237 | None | 2.6.2 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 208.15 | 208.15 | 165.0 | False | None | None | False | None | False | 34344.75 | 0 | 3609835 | 131237 | None | V-5P20I5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete
16 SWG
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3609836 | 131237 | None | V-5P21I5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.
600mmx600mmx170mm.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3609837 | 131237 | None | 5.6.6 V-6 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 404.08 | 404.08 | 1.0 | False | None | None | False | None | False | 404.08 | 0 | 3609838 | 131237 | None | 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 514.19 | 514.19 | 1.0 | False | None | None | False | None | False | 514.19 | 0 | 3609839 | 131237 | None | 13.18.1 | Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 344.44 | 344.44 | 1.0 | False | None | None | False | None | False | 344.44 | 0 | 3609840 | 131237 | None | 5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kvar | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 | 3609841 | 131237 | None | V-2 13.50.5 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work
40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 376.66 | 376.66 | 50.0 | False | None | None | False | None | False | 18833.0 | 0 | 3609842 | 131237 | None | V-2 13.50.6 | Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 478.25 | 478.25 | 20.0 | False | None | None | False | None | False | 9565.0 | 0 | 3609843 | 131237 | None | V-2 13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 358.07 | 358.07 | 185.0 | False | None | None | False | None | False | 66242.95 | 0 | 3609844 | 131237 | None | V-2 13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 477.02 | 477.02 | 120.0 | False | None | None | False | None | False | 57242.4 | 0 | 3609845 | 131237 | None | V-2 IT.NO 13.47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 244.08 | 244.08 | 35.0 | False | None | None | False | None | False | 8542.8 | 0 | 3609846 | 131237 | None | V-2 IT.NO 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 360.55 | 360.55 | 50.0 | False | None | None | False | None | False | 18027.5 | 0 | 3609847 | 131237 | None | V-2 P.NO 128 IT.NO 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 302.32 | 302.32 | 55.0 | False | None | None | False | None | False | 16627.6 | 0 | 3609848 | 131237 | None | V-2 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed
to wooden cleats with C.P. brass screws and washers complete."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1511.58 | 1511.58 | 21.0 | False | None | None | False | None | False | 31743.18 | 0 | 3609849 | 131237 | None | V-2 P.NO 127 IT.NO 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6891.32 | 6891.32 | 4.0 | False | None | None | False | None | False | 27565.28 | 0 | 3609850 | 131237 | None | V-2 P.NO 130 IT.NO 14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 614.54 | 614.54 | 4.0 | False | None | None | False | None | False | 2458.16 | 0 | 3609851 | 131237 | None | V-2 P.NO 123 IT.NO 14.38 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of
the same materials with snap fittings of approved quality and colour,
weighing not less than 105 g"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 179.66 | 179.66 | 4.0 | False | None | None | False | None | False | 718.64 | 0 | 3609852 | 131237 | None | V-2 P.NO 178 IT.NO 14.3.1 | Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush
bend, overflow arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete, including
painting of fittings and brackets, cutting and making good the walls and
floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 7405.5 | 7405.5 | 9.0 | False | None | None | False | None | False | 66649.5 | 0 | 3609853 | 131237 | None | V-2 P.NO 124 IT.NO14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6051.28 | 6051.28 | 10.0 | False | None | None | False | None | False | 60512.8 | 0 | 3609854 | 131237 | None | V-2 P.NO 126 IT.NO 14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6296.6 | 6296.6 | 2.0 | False | None | None | False | None | False | 12593.2 | 0 | 3609855 | 131237 | None | V-2 P.NO 126 IT.NO 14.10.1.1 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per
IS:13983 with C.I. brackets and stainless steel plug 40 mm, including
painting of fittings and brackets, cutting and making good the walls
wherever required : (510x1040 mm bowl depth 250 mm)"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6960.7 | 6960.7 | 4.0 | False | None | None | False | None | False | 27842.8 | 0 | 3609856 | 131237 | None | V-2 13.15 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 898.28 | 898.28 | 12.0 | False | None | None | False | None | False | 10779.36 | 0 | 3609857 | 131237 | None | V-2 P.NO 124 IT.NO 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3818.6 | 3818.6 | 13.0 | False | None | None | False | None | False | 49641.8 | 0 | 3609858 | 131237 | None | V-2 P.NO 120 IT.NO 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 382.85 | 382.85 | 90.0 | False | None | None | False | None | False | 34456.5 | 0 | 3609859 | 131237 | None | V-2 P.NO 120 IT.NO 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 469.58 | 469.58 | 70.0 | False | None | None | False | None | False | 32870.6 | 0 | 3609860 | 131237 | None | V-2 p.NO 120 IT.NO 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
25 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 70.0 | False | None | None | False | None | False | 41370.0 | 0 | 3609861 | 131237 | None | V-2 P.NO 120 IT.NO 13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
32 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 690.12 | 690.12 | 30.0 | False | None | None | False | None | False | 20703.6 | 0 | 3609862 | 131237 | None | V-2 P.NO 120 IT.NO 13.31.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
40 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 664.1 | 664.1 | 20.0 | False | None | None | False | None | False | 13282.0 | 0 | 3609863 | 131237 | None | V-2 P.NO 120IT.NO 13.31.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
50 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 967.66 | 967.66 | 20.0 | False | None | None | False | None | False | 19353.2 | 0 | 3609864 | 131237 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
20mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 268.86 | 268.86 | 50.0 | False | None | None | False | None | False | 13443.0 | 0 | 3609865 | 131237 | None | V-2 P.NO 120 IT.NO 13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
25mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 366.74 | 366.74 | 50.0 | False | None | None | False | None | False | 18337.0 | 0 | 3609866 | 131237 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
40mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 215.0 | False | None | None | False | None | False | 127065.0 | 0 | 3609867 | 131237 | None | V-2 P.NO 120 IT.NO 13.33.7 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
65mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 1734.6 | 1734.6 | 25.0 | False | None | None | False | None | False | 43365.0 | 0 | 3609868 | 131237 | None | V-2 P.NO 120 IT.NO 13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
50mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 893.32 | 893.32 | 40.0 | False | None | None | False | None | False | 35732.8 | 0 | 3609869 | 131237 | None | V2 13.5.2 | Providing and fixing ball valve (brass) of approved quality, High or low
pressure, with plastic floats complete :"
25 mm nominal bore
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 411.35 | 411.35 | 12.0 | False | None | None | False | None | False | 4936.2 | 0 | 3609870 | 131237 | None | V2-13.4 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 32 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 740.92 | 740.92 | 7.0 | False | None | None | False | None | False | 5186.44 | 0 | 3609871 | 131237 | None | V-2 13.4.3 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 40 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 869.78 | 869.78 | 9.0 | False | None | None | False | None | False | 7828.02 | 0 | 3609872 | 131237 | None | v2-13.4.4 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 50 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1059.35 | 1059.35 | 2.0 | False | None | None | False | None | False | 2118.7 | 0 | 3609873 | 131237 | None | V-2,A-13, IT.NO 13.2.1 | Brass bib-cock 15 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 354.35 | 354.35 | 19.0 | False | None | None | False | None | False | 6732.65 | 0 | 3609874 | 131237 | None | V-2 IT.NO 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Ltr | 11.15 | 11.15 | 3000.0 | False | None | None | False | None | False | 33450.0 | 0 | 3609875 | 131237 | None | V2 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 182.13 | 182.13 | 125.0 | False | None | None | False | None | False | 22766.25 | 0 | 3609876 | 131237 | None | Market Rate | Providing and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 177.0 | 177.0 | 55.0 | False | None | None | False | None | False | 9735.0 | 0 | 3609877 | 131237 | None | Market Rate | Air Vent Cowel
75mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 413.0 | 413.0 | 12.0 | False | None | None | False | None | False | 4956.0 | 0 | 3609878 | 131237 | None | Market Rate | Air Vent Cowel
110mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 590.0 | 590.0 | 12.0 | False | None | None | False | None | False | 7080.0 | 0 | 3609879 | 131237 | None | Market Rate | Supplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6844.0 | 6844.0 | 9.0 | False | None | None | False | None | False | 61596.0 | 0 | 3609880 | 131237 | None | Market Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2183.0 | 2183.0 | 9.0 | False | None | None | False | None | False | 19647.0 | 0 | 3609881 | 131237 | None | Market Rate | Supplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 767.0 | 767.0 | 95.0 | False | None | None | False | None | False | 72865.0 | 0 | 3609882 | 131237 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
a) 65mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4130.0 | 4130.0 | 2.0 | False | None | None | False | None | False | 8260.0 | 0 | 3609883 | 131237 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
b) 50mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3304.0 | 3304.0 | 4.0 | False | None | None | False | None | False | 13216.0 | 0 | 3609884 | 131237 | None | V2 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Unit | 345.68 | 345.68 | 4.0 | False | None | None | False | None | False | 1382.72 | 0 | 3609885 | 131237 | None | V2 9.29 | Providing and laying flooring and steps fine dressed granite stone slabs
40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with
cement mortar 1:3 over existing cement concrete bed , including cost
of materials, mortar, labour, curing complete as per specifications."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 5335.13 | 5335.13 | 18.0 | False | None | None | False | None | False | 96032.34 | 0 | 3609886 | 131237 | None | V2 10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded
and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti
tions by cutting a chase of appropriate width with chase cutter and embed
ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3455.57 | 3455.57 | 10.0 | False | None | None | False | None | False | 34555.7 | 0 | 3609887 | 131237 | None | V2 13.28 | Providing and fixing PTMT extension nipple for water tank pipe, fittings
of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 79.3 | 79.3 | 70.0 | False | None | None | False | None | False | 5551.0 | 0 | 3609888 | 131237 | None | 14.36.1 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of
approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g
"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 111.51 | 111.51 | 23.0 | False | None | None | False | None | False | 2564.73 | 0 | 3609889 | 131237 | None | 14.37.1 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective
length of tail pipe 260 mm from the centre of the waste coupling, 77 mm
breadth with 25 mm minimum water seal, weighing not less than 260 g"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Unit | 379.13 | 379.13 | 23.0 | False | None | None | False | None | False | 8719.99 | 0 | 3609890 | 131237 | None | 13.8.1.1 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 102.84 | 102.84 | 23.0 | False | None | None | False | None | False | 2365.32 | 0 | 3609891 | 131237 | None | 14.22.A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1003.59 | 1003.59 | 23.0 | False | None | None | False | None | False | 23082.57 | 0 | 3609892 | 131237 | None | 13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 768.18 | 768.18 | 53.0 | False | None | None | False | None | False | 40713.54 | 0 | 3609893 | 131237 | None | V2 14.63A | Providing and fixing Single lever sink mixer with swivel spout top
outlet wall mountable made of Stainless steel with all concealed fitting
arrangements & all necessary accesories complete - Class Economy "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4667.31 | 4667.31 | 4.0 | False | None | None | False | None | False | 18669.24 | 0 | 3609894 | 131237 | None | 14.4.1 | Providing and fixing white vitreous china flat back or wall corner type
lipped front urinal basin of 430x260x350 mm and 340x410x265 mm
sizes respectively with automatic flushing cistern with standard flush
pipe and C.P. brass spreaders with brass unions and G.I clamps complete,
including painting of fittings and brackets, cutting and making good the
walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 5518.51 | 5518.51 | 4.0 | False | None | None | False | None | False | 22074.04 | 0 | 3609895 | 131237 | None | ELE 7.3 | Supplying, installation, testing and commissioning of solar hot water
heater comprising of solar Flat Plate Collector (FPC) of size
2120x1040x100mm and stainless steel hot water storage tank with
stainless steel heat exchanger absorber made of copper sheet and
copper tube of following capacity aluminium box collector with
appropriate capacity electrical back up arrangement excluding inlet
and out let pipes. SS Model with 100mm thick of 48Kg/M3 density
Rock wool insulation with 22SWG Aluminium cladding."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 39372.94 | 39372.94 | 3.0 | False | None | None | False | None | False | 118118.82 | 0 | 3609896 | 131237 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-110mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 944.0 | 944.0 | 10.0 | False | None | None | False | None | False | 9440.0 | 0 | 3609897 | 131237 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-75mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 767.0 | 767.0 | 2.0 | False | None | None | False | None | False | 1534.0 | 0 | 3609898 | 131237 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-160MM dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1298.0 | 1298.0 | 1.0 | False | None | None | False | None | False | 1298.0 | 0 | 3609899 | 131237 | None | V-1,P.NO 6,IT.NO 1.4.1 | Earth work excavation by manual means for drains,canals, waste weir,
draft, approach channels, key trenches, foundation of bridges and
such simillar works in all kinds of soils , as per drawing and technical
specifications, including setting out, shoring, strutting, barricading,
caution lights, removal of stumps and other deleterious matter,
excavated surface leveled and sides neatly dressed disposing off the
excavated stuff or sorting & stacking the selected stuff for reuse in a
radius of 50 m and lift upto 1.5 m including cost of labour, tools & other
appurtenaces required to complete the work."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 299.84 | 299.84 | 224.0 | False | None | None | False | None | False | 67164.16 | 0 | 3609900 | 131237 | None | V-1 P.NO 7 IT.NO 1.11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 536.49 | 536.49 | 224.0 | False | None | None | False | None | False | 120173.76 | 0 | 3609901 | 131237 | None | V-5 P.NO 134 IT.NO 10.3 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013
with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of
elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing
the pipes alround to a depth of not less than 15 cms. with soft gravel
or selected earth available from the excavation etc. complete and giving
necessary hydraulic test to the required pressure as per ISS (contractor
will make his own arrangements for procuring water for testing) etc.
complete. for:"
Pipes of SN8 Self Fit - 160mm dia.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 764.46 | 764.46 | 300.0 | False | None | None | False | None | False | 229338.0 | 0 | 3609902 | 131237 | None | V-5 P.NO 134 IT.NO 10.2.4 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ).
- do - 160 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 713.66 | 713.66 | 70.0 | False | None | None | False | None | False | 49956.2 | 0 | 3609903 | 131237 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6757.51 | 6757.51 | 45.0 | False | None | None | False | None | False | 304087.95 | 0 | 3609904 | 131237 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6757.51 | 6757.51 | 15.0 | False | None | None | False | None | False | 101362.65 | 0 | 3609905 | 131237 | None | 13.39 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete
with C.I. grating brick masonry chamber 150 x 100 mm size P type With
Non Modular common burnt clay bricks of designation 3.5 & with water
tight C.I. cover with frame of 300 x300 mm size (inside) the weight of
cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as
per standard design:"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3197.86 | 3197.86 | 25.0 | False | None | None | False | None | False | 79946.5 | 0 | 3609906 | 131237 | None | 16.18 | Construction of RCC Machinehole chambers of 1:1.5:3 proportion
or approved type Cast-insitu / Pre-cast RCC Machinehole chambers,
constructed using form vibrators of standard type, with barricading,
danger lighting and using of sight rails and boning rods wherever
necessary, shoring and strutting wherever required using Ordinary
Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down
graded jelly, well graded sand and steel of approved quality, 200 mm
thick top concrete slab, having wall thickness and raft thickness as in
approved drawings and with an offset in raft alround the chamber as
in approved drawing, benching concrete with 1:6 slope towards the
central drain finished smooth, including fixing and grouting of pipes,
including conveying to work spot supply and fixing SFRC Machinehole
cover and frame (Heavy duty) conforming to IS:12592 with latest
amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3
mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia.
Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as
detailed in Technical specifications, including stone grit beding wherever
required, watering, curing, engraving Machinehole number with flow
direction on the inner cylindrical surface etc., complete including
cost of reinforcement steel and fabrication charges and also cost and
conveyance of all materials, labour with all lead and lifts. The Pre-cast
RCC Machinehole are for various diamters and depths as stated below
and as per detailed drawings, specifications and direction of the Engineer.
For 1.2m dia Machinehole:"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 97246.63 | 97246.63 | 1.0 | False | None | None | False | None | False | 97246.63 | 0 | 3609907 | 131237 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
External & Shafts & Terrace
40mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 80.0 | False | None | None | False | None | False | 47280.0 | 0 | 3609908 | 131237 | None | 13.23 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g)
T.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1665.22 | 1665.22 | 5.0 | False | None | None | False | None | False | 8326.1 | 0 | 3609909 | 131237 | None | 13.40.1 V-5 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 19340.79 | 19340.79 | 2.0 | False | None | None | False | None | False | 38681.58 | 0 | 3609910 | 131237 | None | 13.32 V-5 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and
equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 8053.5 | 8053.5 | 2.0 | False | None | None | False | None | False | 16107.0 | 0 | 3609911 | 131237 | None | PWD ELE SR V-6 IT.NO 2.2.1 | WIRES & CABLES
Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Short point up to 3Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 333.29 | 333.29 | 25.0 | False | None | None | False | None | False | 8332.25 | 0 | 3609912 | 131237 | None | PWD ELE SR V-10 IT.NO 2.2.2 | Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Pack | 469.58 | 469.58 | 36.0 | False | None | None | False | None | False | 16904.88 | 0 | 3609913 | 131237 | None | PWD ELE SR V-11 IT.NO 2.2.3 | Point wiring using Copper wire without switch.
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Long point above 6Mtr up to 10Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 687.65 | 687.65 | 63.0 | False | None | None | False | None | False | 43321.95 | 0 | 3609914 | 131237 | None | PWD ELE SR V-12 IT.NO 2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 838.8 | 838.8 | 8.0 | False | None | None | False | None | False | 6710.4 | 0 | 3609915 | 131237 | None | PWD ELE SR V-14 IT.NO 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
1-3Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 170.98 | 170.98 | 25.0 | False | None | None | False | None | False | 4274.5 | 0 | 3609916 | 131237 | None | PWD ELE SR V-15 IT.NO 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
4-5Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 197.0 | 197.0 | 32.0 | False | None | None | False | None | False | 6304.0 | 0 | 3609917 | 131237 | None | PWD ELE SR V-16 IT.NO 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
6Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 219.3 | 219.3 | 16.0 | False | None | None | False | None | False | 3508.8 | 0 | 3609918 | 131237 | None | PWD ELE SR V-17 IT.NO 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
8 Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 272.58 | 272.58 | 7.0 | False | None | None | False | None | False | 1908.06 | 0 | 3609919 | 131237 | None | PWD ELE SR V-18 IT.NO 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
10-12Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 323.38 | 323.38 | 20.0 | False | None | None | False | None | False | 6467.6 | 0 | 3609920 | 131237 | None | PWD ELE SR V-20 IT.NO 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
1 to 3 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 199.48 | 199.48 | 32.0 | False | None | None | False | None | False | 6383.36 | 0 | 3609921 | 131237 | None | PWD ELE SR V-21 IT.NO 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
4 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 216.83 | 216.83 | 16.0 | False | None | None | False | None | False | 3469.28 | 0 | 3609922 | 131237 | None | PWD ELE SR V-22 IT.NO 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
6 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 289.93 | 289.93 | 7.0 | False | None | None | False | None | False | 2029.51 | 0 | 3609923 | 131237 | None | PWD ELE SR V-23 IT.NO 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
8 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 351.88 | 351.88 | 21.0 | False | None | None | False | None | False | 7389.48 | 0 | 3609924 | 131237 | None | PWD ELE SR V-24 IT.NO 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
10-12 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 426.22 | 426.22 | 31.0 | False | None | None | False | None | False | 13212.82 | 0 | 3609925 | 131237 | None | PWD ELE SR V-26 IT.NO 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps one way Switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 126.38 | 126.38 | 217.0 | False | None | None | False | None | False | 27424.46 | 0 | 3609926 | 131237 | None | PWD ELE SR V-6 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps Two way Switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 205.67 | 205.67 | 2.0 | False | None | None | False | None | False | 411.34 | 0 | 3609927 | 131237 | None | PWD ELE SR V-6,IT.NO 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps 3way socket
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 211.87 | 211.87 | 81.0 | False | None | None | False | None | False | 17161.47 | 0 | 3609928 | 131237 | None | PWD ELE SR V-6,IT.NO 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Stepped Fan Regulator.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 442.32 | 442.32 | 24.0 | False | None | None | False | None | False | 10615.68 | 0 | 3609929 | 131237 | None | PWD ELE SR V-6,IT.NO 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
16Amps one way switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 223.02 | 223.02 | 10.0 | False | None | None | False | None | False | 2230.2 | 0 | 3609930 | 131237 | None | PWD ELE SR V-6, IT.NO 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
32Amps DP switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 403.91 | 403.91 | 15.0 | False | None | None | False | None | False | 6058.65 | 0 | 3609931 | 131237 | None | PWD ELE SR V-6,IT.NO 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6/16Amps universal socket
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 292.4 | 292.4 | 25.0 | False | None | None | False | None | False | 7310.0 | 0 | 3609932 | 131237 | None | PWD ELE SR V-6,IT.NO 1.13 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Supplyin and Fixing Metal Fan Box with Round Hook.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 144.96 | 144.96 | 24.0 | False | None | None | False | None | False | 3479.04 | 0 | 3609933 | 131237 | None | PWD ELE SR V-6,IT.NO-1.2.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
19/20mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 81.77 | 81.77 | 890.0 | False | None | None | False | None | False | 72775.3 | 0 | 3609934 | 131237 | None | PWD ELE SR V-6,IT.NO 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
25mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 96.64 | 96.64 | 1030.0 | False | None | None | False | None | False | 99539.2 | 0 | 3609935 | 131237 | None | PWD ELE SR V-6, IT.NO .2.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
32mm dia 2.5mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 127.62 | 127.62 | 250.0 | False | None | None | False | None | False | 31905.0 | 0 | 3609936 | 131237 | None | PWD ELE SR V-6,IT.NO1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
19/20mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 84.25 | 84.25 | 445.0 | False | None | None | False | None | False | 37491.25 | 0 | 3609937 | 131237 | None | PWD ELE SR V-6,IT.NO-1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 97.88 | 97.88 | 515.0 | False | None | None | False | None | False | 50408.2 | 0 | 3609938 | 131237 | None | PWD ELE SR V-6,IT.NO-1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
32mm dia 2.5mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 122.66 | 122.66 | 150.0 | False | None | None | False | None | False | 18399.0 | 0 | 3609939 | 131237 | None | PWD ELE SR V-6,IT.NO 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 32.21 | 32.21 | 470.0 | False | None | None | False | None | False | 15138.7 | 0 | 3609940 | 131237 | None | PWD ELE SR V-6,IT.NO 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 52.04 | 52.04 | 1530.0 | False | None | None | False | None | False | 79621.2 | 0 | 3609941 | 131237 | None | PWD ELE SR V-6,IT.NO 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
4 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 78.06 | 78.06 | 740.0 | False | None | None | False | None | False | 57764.4 | 0 | 3609942 | 131237 | None | PWD ELE SR V-6,IT.NO 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
6 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 113.99 | 113.99 | 580.0 | False | None | None | False | None | False | 66114.2 | 0 | 3609943 | 131237 | None | PWD ELE SR V-6,IT.NO 5.19.11 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure
III - Double Door
4 Way TP & N
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 5003.08 | 5003.08 | 2.0 | False | None | None | False | None | False | 10006.16 | 0 | 3609944 | 131237 | None | PWD ELE SR V-6,IT.NO 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
6-32Amps SP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 514.19 | 514.19 | 62.0 | False | None | None | False | None | False | 31879.78 | 0 | 3609945 | 131237 | None | PWD ELE SR V-6 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
40Amps TPN
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3771.52 | 3771.52 | 2.0 | False | None | None | False | None | False | 7543.04 | 0 | 3609946 | 131237 | None | PWD ELE SR V-6,IT.NO 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board
16-25 Amps 2 pole
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 5299.2 | 5299.2 | 2.0 | False | None | None | False | None | False | 10598.4 | 0 | 3609947 | 131237 | None | PWD ELE SR V-6,IT.NO 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only)
32mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 480.73 | 480.73 | 10.0 | False | None | None | False | None | False | 4807.3 | 0 | 3609948 | 131237 | None | PWD ELE SR V-6,IT.NO 6.17.8 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.
35 sqmm Long Barrel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 39.65 | 39.65 | 16.0 | False | None | None | False | None | False | 634.4 | 0 | 3609949 | 131237 | None | V-6 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4348.89 | 4348.89 | 7.0 | False | None | None | False | None | False | 30442.23 | 0 | 3609950 | 131237 | None | V-6 12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x3mm GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 101.6 | 101.6 | 100.0 | False | None | None | False | None | False | 10160.0 | 0 | 3609951 | 131237 | None | 12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
600X600X3 GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1084.13 | 1084.13 | 6.0 | False | None | None | False | None | False | 6504.78 | 0 | 3609952 | 131237 | None | 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1096.52 | 1096.52 | 19.0 | False | None | None | False | None | False | 20833.88 | 0 | 3609953 | 131237 | None | 11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1640.44 | 1640.44 | 5.0 | False | None | None | False | None | False | 8202.2 | 0 | 3609954 | 131237 | None | 11.3.2 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 854.91 | 854.91 | 51.0 | False | None | None | False | None | False | 43600.41 | 0 | 3609955 | 131237 | None | 11.11.3 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 184.61 | 184.61 | 15.0 | False | None | None | False | None | False | 2769.15 | 0 | 3609956 | 131237 | None | PWD ELE SR V-6,IT.NO 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1848.59 | 1848.59 | 13.0 | False | None | None | False | None | False | 24031.67 | 0 | 3609957 | 131237 | None | PWD ELE SR V-6,IT.NO 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3316.8 | 3316.8 | 24.0 | False | None | None | False | None | False | 79603.2 | 0 | 3609958 | 131237 | None | PWD ELE SR V-6,IT.NO 13.11 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.
On wall / ceiling / Rafter / Girders
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 390.29 | 390.29 | 24.0 | False | None | None | False | None | False | 9366.96 | 0 | 3609959 | 131237 | None | PWD ELE SR V-6,IT.NO 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 151.16 | 151.16 | 83.0 | False | None | None | False | None | False | 12546.28 | 0 | 3609960 | 131237 | None | PWD ELE SR V-6,IT.NO 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 875.97 | 875.97 | 13.0 | False | None | None | False | None | False | 11387.61 | 0 | 3609961 | 131237 | None | PWD ELE SR V-6,IT.NO 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 200.72 | 200.72 | 3.0 | False | None | None | False | None | False | 602.16 | 0 | 3609962 | 131237 | None | PWD ELE SR V-6,IT.NO 5.42.1 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete
16SWG
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 86000.0 | False | None | None | False | None | False | 45580.0 | 0 | 3609963 | 131237 | None | PWD ELE SR V-6,IT.NO 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 4255.97 | 4255.97 | 5.0 | False | None | None | False | None | False | 21279.85 | 0 | 3609964 | 131237 | None | PWD ELE SR V-6,IT.NO 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
40x40x6mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 377.9 | 377.9 | 10.0 | False | None | None | False | None | False | 3779.0 | 0 | 3609965 | 131237 | None | PWD ELE SR V-6,IT.NO 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
50x100x50x6mm C channel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 936.68 | 936.68 | 10.0 | False | None | None | False | None | False | 9366.8 | 0 | 3609966 | 131237 | None | PWD ELE SR V-6,IT.NO 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs)
100Amps 25kA
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 10515.39 | 10515.39 | 1.0 | False | None | None | False | None | False | 10515.39 | 0 | 3609967 | 131237 | None | PWD ELE SR V-6,iT.NO 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
50-63Amps DP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3826.03 | 3826.03 | 10.0 | False | None | None | False | None | False | 38260.3 | 0 | 3609968 | 131237 | None | PWD ELE SR V-6,IT.NO 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 11541.29 | 11541.29 | 1.0 | False | None | None | False | None | False | 11541.29 | 0 | 3609969 | 131237 | None | PWD ELE SR V-6,IT.NO 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3609970 | 131237 | None | PWD ELE SR V-6,IT.NO 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 696.32 | 696.32 | 3.0 | False | None | None | False | None | False | 2088.96 | 0 | 3609971 | 131237 | None | PWD ELE SR V-6,IT.NO5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kvar | 594.72 | 594.72 | 15.0 | False | None | None | False | None | False | 8920.8 | 0 | 3609972 | 131237 | None | 5.19.9 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2885.63 | 2885.63 | 2.0 | False | None | None | False | None | False | 5771.26 | 0 | 3609973 | 131237 | None | 5.19.12 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6120.66 | 6120.66 | 1.0 | False | None | None | False | None | False | 6120.66 | 0 | 3609974 | 131237 | None | 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3826.03 | 3826.03 | 1.0 | False | None | None | False | None | False | 3826.03 | 0 | 3609975 | 131237 | None | 5.20.8 | Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6377.13 | 6377.13 | 3.0 | False | None | None | False | None | False | 19131.39 | 0 | 3609976 | 131237 | None | 32.05 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 109549.9 | 109549.9 | 0.1 | False | None | None | False | None | False | 10954.99 | 0 | 3609977 | 131237 | None | 32.09 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 190882.82 | 190882.82 | 0.05 | False | None | None | False | None | False | 9544.141 | 0 | 3609978 | 131237 | None | 32.13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 393892.97 | 393892.97 | 0.1 | False | None | None | False | None | False | 39389.297 | 0 | 3609979 | 131237 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 25877.75 | 25877.75 | 0.05 | False | None | None | False | None | False | 1293.8875 | 0 | 3609980 | 131237 | None | 31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 38581.22 | 38581.22 | 0.2 | False | None | None | False | None | False | 7716.244 | 0 | 3609981 | 131237 | None | 6.17.6 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 15.41 | 15.41 | 20.0 | False | None | None | False | None | False | 308.2 | 0 | 3609982 | 131237 | None | 16.17.10 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 148.68 | 148.68 | 16.0 | False | None | None | False | None | False | 2378.88 | 0 | 3609983 | 131237 | None | 11.11.5 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 333.29 | 333.29 | 9.0 | False | None | None | False | None | False | 2999.61 | 0 | 3609984 | 131237 | None | 11.6.3 | Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 5641.17 | 5641.17 | 8.0 | False | None | None | False | None | False | 45129.36 | 0 | 3609985 | 131237 | None | 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4985.74 | 4985.74 | 2.0 | False | None | None | False | None | False | 9971.48 | 0 | 3609986 | 131237 | None | 13.4.1 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1810.18 | 1810.18 | 3.0 | False | None | None | False | None | False | 5430.54 | 0 | 3609987 | 131237 | None | 5.14.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 2738.19 | 2738.19 | 2.0 | False | None | None | False | None | False | 5476.38 | 0 | 3609988 | 131237 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 169.74 | 169.74 | 24.0 | False | None | None | False | None | False | 4073.76 | 0 | 3609989 | 131237 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 395.24 | 395.24 | 31.0 | False | None | None | False | None | False | 12252.44 | 0 | 3609990 | 131237 | None | 2.2.5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 1225.37 | 1225.37 | 4.0 | False | None | None | False | None | False | 4901.48 | 0 | 3609991 | 131237 | None | 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 144.96 | 144.96 | 6.0 | False | None | None | False | None | False | 869.76 | 0 | 3609992 | 131237 | None | 12.46 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 78.06 | 78.06 | 21.0 | False | None | None | False | None | False | 1639.26 | 0 | 3609993 | 131237 | None | 3.6.11 | TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 193.28 | 193.28 | 2.0 | False | None | None | False | None | False | 386.56 | 0 | 3609994 | 131237 | None | 12.2.1 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 304.79 | 304.79 | 1.0 | False | None | None | False | None | False | 304.79 | 0 | 3609995 | 131237 | None | 32.02 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 98168.45 | 98168.45 | 0.1 | False | None | None | False | None | False | 9816.845 | 0 | 3609996 | 131237 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 25877.75 | 25877.75 | 0.1 | False | None | None | False | None | False | 2587.775 | 0 | 3609997 | 131237 | None | pwd sr | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 15.41 | 15.41 | 15.0 | False | None | None | False | None | False | 231.15 | 0 | 3609998 | 131237 | None | 11..11.7 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 527.81 | 527.81 | 3.0 | False | None | None | False | None | False | 1583.43 | 0 | 3609999 | 131237 | None | 12.27 | Supplying & Fixing of Special Type pigmy and candle lamp.
Operating voltage range from 180V to 265V, 50Hz AC power Supply"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 64.43 | 64.43 | 2.0 | False | None | None | False | None | False | 128.86 | 0 | 3610000 | 131237 | None | 11.8.1 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3004.58 | 3004.58 | 1.0 | False | None | None | False | None | False | 3004.58 | 0 | 3610001 | 131237 | None | 5.7.2 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 298.6 | 298.6 | 1.0 | False | None | None | False | None | False | 298.6 | 0 | 3610002 | 131237 | None | 5.30 | Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1709.82 | 1709.82 | 1.0 | False | None | None | False | None | False | 1709.82 | 0 | 3610003 | 131237 | None | 7.1.3 | Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 12689.84 | 12689.84 | 1.0 | False | None | None | False | None | False | 12689.84 | 0 | 3610004 | 131237 | None | PWD SR 2023-24 Volume 6 It No-9.3.3 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 84726.54 | 84726.54 | 1.0 | False | None | None | False | None | False | 84726.54 | 0 | 3610005 | 131237 | None | PWD SR 2023-24 Volume 6 It No-9.5.9 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 19693.91 | 19693.91 | 4.0 | False | None | None | False | None | False | 78775.64 | 0 | 3610006 | 131237 | None | A.R | Item Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 300000.0 | 300000.0 | 1.0 | False | None | None | False | None | False | 300000.0 | 0 | 3610007 | 131237 | None | LQR | IP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 23836.0 | 23836.0 | 4.0 | False | None | None | False | None | False | 95344.0 | 0 | 3610008 | 131237 | None | LQR | IP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 25606.0 | 25606.0 | 2.0 | False | None | None | False | None | False | 51212.0 | 0 | 3610009 | 131237 | None | LQR | Supplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3610010 | 131237 | None | LQR | Supply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 17110.0 | 17110.0 | 2.0 | False | None | None | False | None | False | 34220.0 | 0 | 3610011 | 131237 | None | LQR | Supply and Installation of I/Os
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 147.5 | 147.5 | 12.0 | False | None | None | False | None | False | 1770.0 | 0 | 3610012 | 131237 | None | LQR | Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 265.5 | 265.5 | 12.0 | False | None | None | False | None | False | 3186.0 | 0 | 3610013 | 131237 | None | LQR | Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 336.3 | 336.3 | 6.0 | False | None | None | False | None | False | 2017.8 | 0 | 3610014 | 131237 | None | LQR | Supply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3610015 | 131237 | None | V-6 8.1 | Supplying and drawing UTP-CAT 6E LAN cable
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 47.08 | 47.08 | 600.0 | False | None | None | False | None | False | 28248.0 | 0 | 3610016 | 131237 | None | 1.2.2 | Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 96.64 | 96.64 | 500.0 | False | None | None | False | None | False | 48320.0 | 0 | 3610017 | 131237 | None | 8.12.3 | Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3778.95 | 3778.95 | 1.0 | False | None | None | False | None | False | 3778.95 | 0 | 3610018 | 131237 | None | 8.4.1 v-6 | Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 6061.19 | 6061.19 | 1.0 | False | None | None | False | None | False | 6061.19 | 0 | 3610019 | 131237 | None | 1.01 | Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 8767.16 | 8767.16 | 8.0 | False | None | None | False | None | False | 70137.28 | 0 | 3610020 | 131237 | None | 2.02 | Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 1379.01 | 1379.01 | 8.0 | False | None | None | False | None | False | 11032.08 | 0 | 3610021 | 131237 | None | 6.05 | Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 107.79 | 107.79 | 6.0 | False | None | None | False | None | False | 646.74 | 0 | 3610022 | 131237 | None | 13.12 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 59.47 | 59.47 | 6.0 | False | None | None | False | None | False | 356.82 | 0 | 3610023 | 131237 | None | 2.16 | Supply of Spiral Earth Electrode
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 296.12 | 296.12 | 11.0 | False | None | None | False | None | False | 3257.32 | 0 | 3610024 | 131237 | None | 2.16 | Erection of Spiral Earth Electrode
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 115.23 | 115.23 | 11.0 | False | None | None | False | None | False | 1267.53 | 0 | 3610025 | 131237 | None | 68.17 | Supply and fixing of Caution/Danger Board
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 185.85 | 185.85 | 6.0 | False | None | None | False | None | False | 1115.1 | 0 | 3610026 | 131237 | None | 4.02 | Supply of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 110.27 | 110.27 | 8.0 | False | None | None | False | None | False | 882.16 | 0 | 3610027 | 131237 | None | 5.09 | Erection of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 52.04 | 52.04 | 8.0 | False | None | None | False | None | False | 416.32 | 0 | 3610028 | 131237 | None | 24.05 | Supply and fixing of 11 kV, 400 Amps Double Break GOS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 26341.14 | 26341.14 | 1.0 | False | None | None | False | None | False | 26341.14 | 0 | 3610029 | 131237 | None | 24.07 | Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 7521.97 | 7521.97 | 1.0 | False | None | None | False | None | False | 7521.97 | 0 | 3610030 | 131237 | None | 25.01 | Supply of DOLO Cut Out
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set of 3 Nos | 7279.13 | 7279.13 | 1.0 | False | None | None | False | None | False | 7279.13 | 0 | 3610031 | 131237 | None | 13.01 | Erection of DOLO Cut Out
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set of 3 Nos | 293.64 | 293.64 | 1.0 | False | None | None | False | None | False | 293.64 | 0 | 3610032 | 131237 | None | 13.07 | Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 210958.34 | 210958.34 | 1.0 | False | None | None | False | None | False | 210958.34 | 0 | 3610033 | 131237 | None | 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 4348.89 | 4348.89 | 8.0 | False | None | None | False | None | False | 34791.12 | 0 | 3610034 | 131237 | None | 12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | MT | 158.59 | 158.59 | 100.0 | False | None | None | False | None | False | 15859.0 | 0 | 3610035 | 131237 | None | 12.58.9 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 2035.68 | 2035.68 | 100.0 | False | None | None | False | None | False | 203568.0 | 0 | 3610036 | 131237 | None | 12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 9194.62 | 9194.62 | 10.0 | False | None | None | False | None | False | 91946.2 | 0 | 3610037 | 131237 | None | 45.07 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 5039.01 | 5039.01 | 4.0 | False | None | None | False | None | False | 20156.04 | 0 | 3610038 | 131237 | None | 45.04 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 3887.98 | 3887.98 | 2.0 | False | None | None | False | None | False | 7775.96 | 0 | 3610039 | 131237 | None | 36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 1102296.17 | 1102296.17 | 0.1 | False | None | None | False | None | False | 110229.617 | 0 | 3610040 | 131237 | None | 38. | Providing chain link fencing 50 mm size of 8 guage properly stretched between
rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be
welded to the Pole and block pipe at top and bottom as required including cost
of all materials, labour, lead and lifts, cutting, bending wherever necessary,
wastage and lapping etc., complete as per the direction of the engineer
incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1222.89 | 1222.89 | 150.0 | False | None | None | False | None | False | 183433.5 | 0 | 3610041 | 131237 | None | 5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 176000.0 | False | None | None | False | None | False | 93280.0 | 0 | 3610042 | 131237 | None | 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 4255.97 | 4255.97 | 6.0 | False | None | None | False | None | False | 25535.82 | 0 | 3610043 | 131237 | None | 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 377.9 | 377.9 | 12.0 | False | None | None | False | None | False | 4534.8 | 0 | 3610044 | 131237 | None | 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 936.68 | 936.68 | 12.0 | False | None | None | False | None | False | 11240.16 | 0 | 3610045 | 131237 | None | 5.15.15 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 29172.26 | 29172.26 | 1.0 | False | None | None | False | None | False | 29172.26 | 0 | 3610046 | 131237 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3610047 | 131237 | None | 10.1.3 | Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have +
1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating
lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting
battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr
at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 558914.14 | 558914.14 | 1.0 | False | None | None | False | None | False | 558914.14 | 0 | 3610048 | 131237 | None | 10.2.2 | Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the
accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 72742.93 | 72742.93 | 1.0 | False | None | None | False | None | False | 72742.93 | 0 | 3610049 | 131237 | None | A.R | Supply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 3540.0 | 3540.0 | 5.0 | False | None | None | False | None | False | 17700.0 | 0 | 3610050 | 131237 | None | A.R | Supply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 236.0 | 236.0 | 50.0 | False | None | None | False | None | False | 11800.0 | 0 | 3610051 | 131237 | None | 58.02 | LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 98973.8 | 98973.8 | 1.0 | False | None | None | False | None | False | 98973.8 | 0 | 3610052 | 131237 | None | 53.01 | CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 24302.99 | 24302.99 | 1.0 | False | None | None | False | None | False | 24302.99 | 0 | 3610053 | 131237 | None | 10.01 | Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 173.46 | 173.46 | 15.0 | False | None | None | False | None | False | 2601.9 | 0 | 3610054 | 131237 | None | v-6 2.02 | Supply of 11 kV, Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr
Long, 145 Kg WL"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 603.39 | 603.39 | 6.0 | False | None | None | False | None | False | 3620.34 | 0 | 3610055 | 131237 | None | v-6 2.02 | Erection of 11 kV, Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr
Long, 145 Kg WL"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 318.42 | 318.42 | 6.0 | False | None | None | False | None | False | 1910.52 | 0 | 3610056 | 131237 | None | v-6 6.06 | Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP
Rod) "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 254.0 | 254.0 | 18.0 | False | None | None | False | None | False | 4572.0 | 0 | 3610057 | 131237 | None | v-6 6.10 | Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 235.45 | 235.45 | 18.0 | False | None | None | False | None | False | 4238.1 | 0 | 3610058 | 131237 | None | 13.12 v-6 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 59.47 | 59.47 | 18.0 | False | None | None | False | None | False | 1070.46 | 0 | 3610059 | 131237 | None | v-6 6.08 | Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 73.1 | 73.1 | 4.0 | False | None | None | False | None | False | 292.4 | 0 | 3610060 | 131237 | None | 7.02 | Supply of Rabbit ACSR Conductor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 57283.93 | 57283.93 | 1.0 | False | None | None | False | None | False | 57283.93 | 0 | 3610061 | 131237 | None | 6.02 V-6 | Erection of Rabbit ACSR Conductor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 5403.28 | 5403.28 | 1.0 | False | None | None | False | None | False | 5403.28 | 0 |
| 1721828234000 | 0 | None | None | Buildings | KANPUR SH IN SHORAPUR TALUK OF YADGIR DISTRICT | 34741282.93 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3610062 | 131238 | None | CSR:V-3 PAGE NO 9 Itm 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | 100 Sqm | 486.93 | 486.93 | 17.49 | False | None | None | False | None | False | 8516.4057 | 0 | 3610063 | 131238 | None | V-1 page 8 itm 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 117.71 | 117.71 | 768.64 | False | None | None | False | None | False | 90476.6144 | 0 | 3610064 | 131238 | None | V-1page 8 itm 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 126.38 | 126.38 | 1311.57 | False | None | None | False | None | False | 165756.2166 | 0 | 3610065 | 131238 | None | V-1page 8 itm 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 449.76 | 449.76 | 230.53 | False | None | None | False | None | False | 103683.1728 | 0 | 3610066 | 131238 | None | V-3page 3 A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 167.27 | 167.27 | 225.13 | False | None | None | False | None | False | 37657.4951 | 0 | 3610067 | 131238 | None | V-2page5 itm 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 146.2 | 146.2 | 774.16 | False | None | None | False | None | False | 113182.192 | 0 | 3610068 | 131238 | None | V-1pg7 itm1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 329.57 | 329.57 | 807.35 | False | None | None | False | None | False | 266078.3395 | 0 | 3610069 | 131238 | None | V-1page7vitm1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 587.29 | 587.29 | 728.89 | False | None | None | False | None | False | 428069.8081 | 0 | 3610070 | 131238 | None | V-1page 15 itm2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7420.37 | 7420.37 | 161.37 | False | None | None | False | None | False | 1197425.1069 | 0 | 3610071 | 131238 | None | V-1page15 itm 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8478.33 | 8478.33 | 177.95 | False | None | None | False | None | False | 1508718.8235 | 0 | 3610072 | 131238 | None | V-1page16 itm 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8635.33 | 8635.33 | 13.4 | False | None | None | False | None | False | 115713.422 | 0 | 3610073 | 131238 | None | V-1page15itm 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 14413.41 | 14413.41 | 55.14 | False | None | None | False | None | False | 794755.4274 | 0 | 3610074 | 131238 | None | V-3page135itm15.4 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 252.76 | 252.76 | 13.0 | False | None | None | False | None | False | 3285.88 | 0 | 3610075 | 131238 | None | V-2page55 itm 8.16.a | Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1533.88 | 1533.88 | 13.81 | False | None | None | False | None | False | 21182.8828 | 0 | 3610076 | 131238 | None | V-1page18itm2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Tonne | 110837.22 | 110837.22 | 50.82 | False | None | None | False | None | False | 5632747.5204 | 0 | 3610077 | 131238 | None | 18-19SR ITM4.21 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 38.94 | 38.94 | 145.02 | False | None | None | False | None | False | 5647.0788 | 0 | 3610078 | 131238 | None | DATA RATE | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 86.14 | 86.14 | 145.02 | False | None | None | False | None | False | 12492.0228 | 0 | 3610079 | 131238 | None | V-2PAGE 9 ITM5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7915.97 | 7915.97 | 8.76 | False | None | None | False | None | False | 69343.8972 | 0 | 3610080 | 131238 | None | V-2PAGE 14 ITM 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1623.09 | 1623.09 | 1313.93 | False | None | None | False | None | False | 2132626.6437 | 0 | 3610081 | 131238 | None | V-2page 14 itm 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks
of size 400x100x200mm having block density more than 1800kg/m3
and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005
including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1367.86 | 1367.86 | 171.24 | False | None | None | False | None | False | 234232.3464 | 0 | 3610082 | 131238 | None | V-2 page100 itm 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 122431.79 | 122431.79 | 1.2 | False | None | None | False | None | False | 146918.148 | 0 | 3610083 | 131238 | None | V-2 page 105 itm 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 1258.82 | 1258.82 | 32.0 | False | None | None | False | None | False | 40282.24 | 0 | 3610084 | 131238 | None | 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 681.45 | 681.45 | 64.0 | False | None | None | False | None | False | 43612.8 | 0 | 3610085 | 131238 | None | 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 464.63 | 464.63 | 32.0 | False | None | None | False | None | False | 14868.16 | 0 | 3610086 | 131238 | None | 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 185.85 | 185.85 | 64.0 | False | None | None | False | None | False | 11894.4 | 0 | 3610087 | 131238 | None | 22.15.9 | PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 86.73 | 86.73 | 128.0 | False | None | None | False | None | False | 11101.44 | 0 | 3610088 | 131238 | None | 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 123.9 | 123.9 | 32.0 | False | None | None | False | None | False | 3964.8 | 0 | 3610089 | 131238 | None | 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 1303.43 | 1303.43 | 32.0 | False | None | None | False | None | False | 41709.76 | 0 | 3610090 | 131238 | None | V-2page69 itm 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 74.34 | 74.34 | 192.0 | False | None | None | False | None | False | 14273.28 | 0 | 3610091 | 131238 | None | 20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 64.43 | 64.43 | 168.45 | False | None | None | False | None | False | 10853.2335 | 0 | 3610092 | 131238 | None | V-2page105 itm 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4115.96 | 4115.96 | 74.84 | False | None | None | False | None | False | 308038.4464 | 0 | 3610093 | 131238 | None | V-2page109 itm 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 8343.43 | 8343.43 | 69.39 | False | None | None | False | None | False | 578950.6077 | 0 | 3610094 | 131238 | None | V-2page109 itm 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 7085.84 | 7085.84 | 6.84 | False | None | None | False | None | False | 48467.1456 | 0 | 3610095 | 131238 | None | V-2page 86itm11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 208.15 | 208.15 | 1600.83 | False | None | None | False | None | False | 333212.7645 | 0 | 3610096 | 131238 | None | V-2page 111itm 12.93.1 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/
cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | m | 869.78 | 869.78 | 64.35 | False | None | None | False | None | False | 55970.343 | 0 | 3610097 | 131238 | None | V-2page84 itm 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kgs | 168.5 | 168.5 | 1724.91 | False | None | None | False | None | False | 290647.335 | 0 | 3610098 | 131238 | None | V-2page 41itm 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 386.57 | 386.57 | 1763.82 | False | None | None | False | None | False | 681839.8974 | 0 | 3610099 | 131238 | None | V-2page 43 itm 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 261.43 | 261.43 | 1176.83 | False | None | None | False | None | False | 307658.6669 | 0 | 3610100 | 131238 | None | V-2page50 itm 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 123.9 | 123.9 | 2919.03 | False | None | None | False | None | False | 361667.817 | 0 | 3610101 | 131238 | None | V-2page42itm 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 432.41 | 432.41 | 975.48 | False | None | None | False | None | False | 421807.3068 | 0 | 3610102 | 131238 | None | V-2page41 itm 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 438.61 | 438.61 | 163.05 | False | None | None | False | None | False | 71515.3605 | 0 | 3610103 | 131238 | None | 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 47.08 | 47.08 | 2013.85 | False | None | None | False | None | False | 94812.058 | 0 | 3610104 | 131238 | None | 10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 254.88 | 254.88 | 13.0 | False | None | None | False | None | False | 3313.44 | 0 | 3610105 | 131238 | None | V-2page 54itm 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 64.43 | 64.43 | 628.05 | False | None | None | False | None | False | 40465.2615 | 0 | 3610106 | 131238 | None | V-2page61itm 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1455.83 | 1455.83 | 580.89 | False | None | None | False | None | False | 845677.0887 | 0 | 3610107 | 131238 | None | V-2page59 itm9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 991.2 | 991.2 | 71.5 | False | None | None | False | None | False | 70870.8 | 0 | 3610108 | 131238 | None | V-2page63 itm 9.32 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3199.1 | 3199.1 | 34.54 | False | None | None | False | None | False | 110496.914 | 0 | 3610109 | 131238 | None | V-2page 4 itm 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 365.51 | 365.51 | 316.07 | False | None | None | False | None | False | 115526.7457 | 0 | 3610110 | 131238 | None | V-2page 60 itm 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1101.47 | 1101.47 | 59.14 | False | None | None | False | None | False | 65140.9358 | 0 | 3610111 | 131238 | None | V-2page65 itmv9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1795.31 | 1795.31 | 259.57 | False | None | None | False | None | False | 466008.6167 | 0 | 3610112 | 131238 | None | V-2 page85 itm11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 700.04 | 700.04 | 357.82 | False | None | None | False | None | False | 250488.3128 | 0 | 3610113 | 131238 | None | V-2 page 48itm 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 157.35 | 157.35 | 2741.14 | False | None | None | False | None | False | 431318.379 | 0 | 3610114 | 131238 | None | V-2page 46itm8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 193.28 | 193.28 | 759.66 | False | None | None | False | None | False | 146827.0848 | 0 | 3610115 | 131238 | None | V-2page47 itm8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 61.95 | 61.95 | 96.21 | False | None | None | False | None | False | 5960.2095 | 0 | 3610116 | 131238 | None | V-2page48 itm 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 142.49 | 142.49 | 76.23 | False | None | None | False | None | False | 10862.0127 | 0 | 3610117 | 131238 | None | V-2page47itm 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 65.67 | 65.67 | 179.6 | False | None | None | False | None | False | 11794.332 | 0 | 3610118 | 131238 | None | 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 838.8 | 838.8 | 179.6 | False | None | None | False | None | False | 150648.48 | 0 | 3610119 | 131238 | None | V-2page64itm 9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 2044.35 | 2044.35 | 17.32 | False | None | None | False | None | False | 35408.142 | 0 | 3610120 | 131238 | None | V-2page77 itm 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 5548.24 | 5548.24 | 5.25 | False | None | None | False | None | False | 29128.26 | 0 | 3610121 | 131238 | None | 15.12 | Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1443.44 | 1443.44 | 726.5 | False | None | None | False | None | False | 1048659.16 | 0 | 3610122 | 131238 | None | V-2PAGE22 ITM 7.17 | Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 411.35 | 411.35 | 24.74 | False | None | None | False | None | False | 10176.799 | 0 | 3610123 | 131238 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 102.35 | False | None | None | False | None | False | 1301658.642 | 0 | 3610124 | 131238 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 13565.56 | 13565.56 | 51.01 | False | None | None | False | None | False | 691979.2156 | 0 | 3610125 | 131238 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 115.4 | False | None | None | False | None | False | 1467624.888 | 0 | 3610126 | 131238 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 7.07 | False | None | None | False | None | False | 89914.2804 | 0 | 3610127 | 131238 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 13565.56 | 13565.56 | 12.12 | False | None | None | False | None | False | 164414.5872 | 0 | 3610128 | 131238 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 11911.13 | 11911.13 | 14.18 | False | None | None | False | None | False | 168899.8234 | 0 | 3610129 | 131238 | None | 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4317.92 | 4317.92 | 20.48 | False | None | None | False | None | False | 88431.0016 | 0 | 3610130 | 131238 | None | 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 141.25 | 141.25 | 36.0 | False | None | None | False | None | False | 5085.0 | 0 | 3610131 | 131238 | None | 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1642.91 | 1642.91 | 56.5 | False | None | None | False | None | False | 92824.415 | 0 | 3610132 | 131238 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 6601.39 | 6601.39 | 30.54 | False | None | None | False | None | False | 201606.4506 | 0 | 3610133 | 131238 | None | 10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4877.94 | 4877.94 | 9.69 | False | None | None | False | None | False | 47267.2386 | 0 | 3610134 | 131238 | None | 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 761.99 | 761.99 | 92.01 | False | None | None | False | None | False | 70110.6999 | 0 | 3610135 | 131238 | None | 8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 350.64 | 350.64 | 215.82 | False | None | None | False | None | False | 75675.1248 | 0 | 3610136 | 131238 | None | 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 360.55 | 360.55 | 68.92 | False | None | None | False | None | False | 24849.106 | 0 | 3610137 | 131238 | None | 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3533.63 | 3533.63 | 11.09 | False | None | None | False | None | False | 39187.9567 | 0 | 3610138 | 131238 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 6601.39 | 6601.39 | 13.73 | False | None | None | False | None | False | 90637.0847 | 0 | 3610139 | 131238 | None | 10.1.1 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4963.43 | 4963.43 | 3.81 | False | None | None | False | None | False | 18910.6683 | 0 | 3610140 | 131238 | None | 1.4.1 V-1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 299.84 | 299.84 | 11.06 | False | None | None | False | None | False | 3316.2304 | 0 | 3610141 | 131238 | None | 1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 320.9 | 320.9 | 1.7 | False | None | None | False | None | False | 545.53 | 0 | 3610142 | 131238 | None | 17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1391.4 | 1391.4 | 7.0 | False | None | None | False | None | False | 9739.8 | 0 | 3610143 | 131238 | None | 17.1 V-2 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1241.48 | 1241.48 | 0.28 | False | None | None | False | None | False | 347.6144 | 0 | 3610144 | 131238 | None | 17.2 V-2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1469.45 | 1469.45 | 0.14 | False | None | None | False | None | False | 205.723 | 0 | 3610145 | 131238 | None | 17. V-2 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1476.89 | 1476.89 | 0.14 | False | None | None | False | None | False | 206.7646 | 0 | 3610146 | 131238 | None | 17.4 V-2 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1659.02 | 1659.02 | 0.14 | False | None | None | False | None | False | 232.2628 | 0 | 3610147 | 131238 | None | 17.14 V-2 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1449.63 | 1449.63 | 1.0 | False | None | None | False | None | False | 1449.63 | 0 | 3610148 | 131238 | None | V3 305.3.4 | Compacting Original Ground
Compacting original ground supporting embankment
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 130.1 | 130.1 | 72.0 | False | None | None | False | None | False | 9367.2 | 0 | 3610149 | 131238 | None | V-3 4.2 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 2922.8 | 2922.8 | 36.0 | False | None | None | False | None | False | 105220.8 | 0 | 3610150 | 131238 | None | V3 6.1 ISSUE RATE | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 6095.88 | 6095.88 | 24.0 | False | None | None | False | None | False | 146301.12 | 0 | 3610151 | 131238 | None | V-3 6.2 ISSUE RATE | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 11107.64 | 11107.64 | 48.0 | False | None | None | False | None | False | 533166.72 | 0 | 3610152 | 131238 | None | V-3 8.10 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 105.32 | 105.32 | 15.0 | False | None | None | False | None | False | 1579.8 | 0 | 3610153 | 131238 | None | V-3 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 87.97 | 87.97 | 448.0 | False | None | None | False | None | False | 39410.56 | 0 | 3610154 | 131238 | None | V-314621A | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)
300 x 250 x 100 mm Kerb Stone
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 296.12 | 296.12 | 150.0 | False | None | None | False | None | False | 44418.0 | 0 | 3610155 | 131238 | None | 2.1.4 V-1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7702.86 | 7702.86 | 2.0 | False | None | None | False | None | False | 15405.72 | 0 | 3610156 | 131238 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 9156.76 | 9156.76 | 10.8 | False | None | None | False | None | False | 98893.008 | 0 | 3610157 | 131238 | None | 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 459.67 | 459.67 | 320.0 | False | None | None | False | None | False | 147094.4 | 0 | 3610158 | 131238 | None | 8.31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 220.54 | 220.54 | 320.0 | False | None | None | False | None | False | 70572.8 | 0 | 3610159 | 131238 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8761.09 | 8761.09 | 9.36 | False | None | None | False | None | False | 82003.8024 | 0 | 3610160 | 131238 | None | 8.20 V-3 | Providing and fixing 1.8 m high GI barbed wire fencing with
2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete,
0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 672.78 | 672.78 | 390.0 | False | None | None | False | None | False | 262384.2 | 0 | 3610161 | 131238 | None | V1 1.15.2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 526.58 | 526.58 | 22.51 | False | None | None | False | None | False | 11853.3158 | 0 | 3610162 | 131238 | None | 2.5.2 V1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8732.83 | 8732.83 | 4.32 | False | None | None | False | None | False | 37725.8256 | 0 | 3610163 | 131238 | None | 2.5.2 V1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 9326.32 | 9326.32 | 5.89 | False | None | None | False | None | False | 54932.0248 | 0 | 3610164 | 131238 | None | V2 15.14 | UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 2072.85 | 2072.85 | 36.6 | False | None | None | False | None | False | 75866.31 | 0 | 3610165 | 131238 | None | V5 18.3 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2430.92 | 2430.92 | 8.0 | False | None | None | False | None | False | 19447.36 | 0 | 3610166 | 131238 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 14413.41 | 14413.41 | 9.87 | False | None | None | False | None | False | 142260.3567 | 0 | 3610167 | 131238 | None | 15.5 V-2 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 749.6 | 749.6 | 63.57 | False | None | None | False | None | False | 47652.072 | 0 | 3610168 | 131238 | None | 8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 110.27 | 110.27 | 20.1 | False | None | None | False | None | False | 2216.427 | 0 | 3610169 | 131238 | None | V-5P140I12.4 | Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3610170 | 131238 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3610171 | 131238 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above 50 Mtrs and upto 100 Mtr
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3610172 | 131238 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above100 Mtrs. and upto 150 Mtr
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3610173 | 131238 | None | V-5P143I12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 2394.99 | 2394.99 | 20.0 | False | None | None | False | None | False | 47899.8 | 0 | 3610174 | 131238 | None | V-5P155I13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 681.45 | 681.45 | 150.0 | False | None | None | False | None | False | 102217.5 | 0 | 3610175 | 131238 | None | V-5P143I12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3610176 | 131238 | None | V-5P154I12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3610177 | 131238 | None | 18-19 SR13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3610178 | 131238 | None | V-5P154I13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.
5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 39817.74 | 39817.74 | 1.0 | False | None | None | False | None | False | 39817.74 | 0 | 3610179 | 131238 | None | V-5P155I13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3610180 | 131238 | None | V-5P155I13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3610181 | 131238 | None | V-5P155I13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3610182 | 131238 | None | V-5P156I13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3610183 | 131238 | None | V-5P156I13.33 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 1672.65 | 1672.65 | 1.0 | False | None | None | False | None | False | 1672.65 | 0 | 3610184 | 131238 | None | 2.6.2 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 208.15 | 208.15 | 165.0 | False | None | None | False | None | False | 34344.75 | 0 | 3610185 | 131238 | None | V-5P20I5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete
16 SWG
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3610186 | 131238 | None | V-5P21I5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.
600mmx600mmx170mm.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3610187 | 131238 | None | 5.6.6 V-6 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 404.08 | 404.08 | 1.0 | False | None | None | False | None | False | 404.08 | 0 | 3610188 | 131238 | None | 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 514.19 | 514.19 | 1.0 | False | None | None | False | None | False | 514.19 | 0 | 3610189 | 131238 | None | 13.18.1 | Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 344.44 | 344.44 | 1.0 | False | None | None | False | None | False | 344.44 | 0 | 3610190 | 131238 | None | 5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kvar | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 | 3610191 | 131238 | None | V-2 13.50.5 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work
40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 376.66 | 376.66 | 50.0 | False | None | None | False | None | False | 18833.0 | 0 | 3610192 | 131238 | None | V-2 13.50.6 | Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 478.25 | 478.25 | 20.0 | False | None | None | False | None | False | 9565.0 | 0 | 3610193 | 131238 | None | V-2 13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 358.07 | 358.07 | 185.0 | False | None | None | False | None | False | 66242.95 | 0 | 3610194 | 131238 | None | V-2 13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 477.02 | 477.02 | 120.0 | False | None | None | False | None | False | 57242.4 | 0 | 3610195 | 131238 | None | V-2 IT.NO 13.47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 244.08 | 244.08 | 35.0 | False | None | None | False | None | False | 8542.8 | 0 | 3610196 | 131238 | None | V-2 IT.NO 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 360.55 | 360.55 | 50.0 | False | None | None | False | None | False | 18027.5 | 0 | 3610197 | 131238 | None | V-2 P.NO 128 IT.NO 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 302.32 | 302.32 | 55.0 | False | None | None | False | None | False | 16627.6 | 0 | 3610198 | 131238 | None | V-2 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed
to wooden cleats with C.P. brass screws and washers complete."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1511.58 | 1511.58 | 21.0 | False | None | None | False | None | False | 31743.18 | 0 | 3610199 | 131238 | None | V-2 P.NO 127 IT.NO 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6891.32 | 6891.32 | 4.0 | False | None | None | False | None | False | 27565.28 | 0 | 3610200 | 131238 | None | V-2 P.NO 130 IT.NO 14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 614.54 | 614.54 | 4.0 | False | None | None | False | None | False | 2458.16 | 0 | 3610201 | 131238 | None | V-2 P.NO 123 IT.NO 14.38 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of
the same materials with snap fittings of approved quality and colour,
weighing not less than 105 g"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 179.66 | 179.66 | 4.0 | False | None | None | False | None | False | 718.64 | 0 | 3610202 | 131238 | None | V-2 P.NO 178 IT.NO 14.3.1 | Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush
bend, overflow arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete, including
painting of fittings and brackets, cutting and making good the walls and
floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 7405.5 | 7405.5 | 9.0 | False | None | None | False | None | False | 66649.5 | 0 | 3610203 | 131238 | None | V-2 P.NO 124 IT.NO14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6051.28 | 6051.28 | 10.0 | False | None | None | False | None | False | 60512.8 | 0 | 3610204 | 131238 | None | V-2 P.NO 126 IT.NO 14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6296.6 | 6296.6 | 2.0 | False | None | None | False | None | False | 12593.2 | 0 | 3610205 | 131238 | None | V-2 P.NO 126 IT.NO 14.10.1.1 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per
IS:13983 with C.I. brackets and stainless steel plug 40 mm, including
painting of fittings and brackets, cutting and making good the walls
wherever required : (510x1040 mm bowl depth 250 mm)"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6960.7 | 6960.7 | 4.0 | False | None | None | False | None | False | 27842.8 | 0 | 3610206 | 131238 | None | V-2 13.15 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 898.28 | 898.28 | 12.0 | False | None | None | False | None | False | 10779.36 | 0 | 3610207 | 131238 | None | V-2 P.NO 124 IT.NO 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3818.6 | 3818.6 | 13.0 | False | None | None | False | None | False | 49641.8 | 0 | 3610208 | 131238 | None | V-2 P.NO 120 IT.NO 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 382.85 | 382.85 | 90.0 | False | None | None | False | None | False | 34456.5 | 0 | 3610209 | 131238 | None | V-2 P.NO 120 IT.NO 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 469.58 | 469.58 | 70.0 | False | None | None | False | None | False | 32870.6 | 0 | 3610210 | 131238 | None | V-2 p.NO 120 IT.NO 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
25 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 70.0 | False | None | None | False | None | False | 41370.0 | 0 | 3610211 | 131238 | None | V-2 P.NO 120 IT.NO 13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
32 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 690.12 | 690.12 | 30.0 | False | None | None | False | None | False | 20703.6 | 0 | 3610212 | 131238 | None | V-2 P.NO 120 IT.NO 13.31.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
40 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 664.1 | 664.1 | 20.0 | False | None | None | False | None | False | 13282.0 | 0 | 3610213 | 131238 | None | V-2 P.NO 120IT.NO 13.31.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
50 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 967.66 | 967.66 | 20.0 | False | None | None | False | None | False | 19353.2 | 0 | 3610214 | 131238 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
20mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 268.86 | 268.86 | 50.0 | False | None | None | False | None | False | 13443.0 | 0 | 3610215 | 131238 | None | V-2 P.NO 120 IT.NO 13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
25mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 366.74 | 366.74 | 50.0 | False | None | None | False | None | False | 18337.0 | 0 | 3610216 | 131238 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
40mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 215.0 | False | None | None | False | None | False | 127065.0 | 0 | 3610217 | 131238 | None | V-2 P.NO 120 IT.NO 13.33.7 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
65mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 1734.6 | 1734.6 | 25.0 | False | None | None | False | None | False | 43365.0 | 0 | 3610218 | 131238 | None | V-2 P.NO 120 IT.NO 13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
50mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 893.32 | 893.32 | 40.0 | False | None | None | False | None | False | 35732.8 | 0 | 3610219 | 131238 | None | V2 13.5.2 | Providing and fixing ball valve (brass) of approved quality, High or low
pressure, with plastic floats complete :"
25 mm nominal bore
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 411.35 | 411.35 | 12.0 | False | None | None | False | None | False | 4936.2 | 0 | 3610220 | 131238 | None | V2-13.4 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 32 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 740.92 | 740.92 | 7.0 | False | None | None | False | None | False | 5186.44 | 0 | 3610221 | 131238 | None | V-2 13.4.3 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 40 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 869.78 | 869.78 | 9.0 | False | None | None | False | None | False | 7828.02 | 0 | 3610222 | 131238 | None | v2-13.4.4 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 50 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1059.35 | 1059.35 | 2.0 | False | None | None | False | None | False | 2118.7 | 0 | 3610223 | 131238 | None | V-2,A-13, IT.NO 13.2.1 | Brass bib-cock 15 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 354.35 | 354.35 | 19.0 | False | None | None | False | None | False | 6732.65 | 0 | 3610224 | 131238 | None | V-2 IT.NO 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Ltr | 11.15 | 11.15 | 3000.0 | False | None | None | False | None | False | 33450.0 | 0 | 3610225 | 131238 | None | V2 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 182.13 | 182.13 | 125.0 | False | None | None | False | None | False | 22766.25 | 0 | 3610226 | 131238 | None | Market Rate | Providing and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 177.0 | 177.0 | 55.0 | False | None | None | False | None | False | 9735.0 | 0 | 3610227 | 131238 | None | Market Rate | Air Vent Cowel
75mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 413.0 | 413.0 | 12.0 | False | None | None | False | None | False | 4956.0 | 0 | 3610228 | 131238 | None | Market Rate | Air Vent Cowel
110mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 590.0 | 590.0 | 12.0 | False | None | None | False | None | False | 7080.0 | 0 | 3610229 | 131238 | None | Market Rate | Supplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6844.0 | 6844.0 | 9.0 | False | None | None | False | None | False | 61596.0 | 0 | 3610230 | 131238 | None | Market Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2183.0 | 2183.0 | 9.0 | False | None | None | False | None | False | 19647.0 | 0 | 3610231 | 131238 | None | Market Rate | Supplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 767.0 | 767.0 | 95.0 | False | None | None | False | None | False | 72865.0 | 0 | 3610232 | 131238 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
a) 65mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4130.0 | 4130.0 | 2.0 | False | None | None | False | None | False | 8260.0 | 0 | 3610233 | 131238 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
b) 50mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3304.0 | 3304.0 | 4.0 | False | None | None | False | None | False | 13216.0 | 0 | 3610234 | 131238 | None | V2 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Unit | 345.68 | 345.68 | 4.0 | False | None | None | False | None | False | 1382.72 | 0 | 3610235 | 131238 | None | V2 9.29 | Providing and laying flooring and steps fine dressed granite stone slabs
40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with
cement mortar 1:3 over existing cement concrete bed , including cost
of materials, mortar, labour, curing complete as per specifications."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 5335.13 | 5335.13 | 18.0 | False | None | None | False | None | False | 96032.34 | 0 | 3610236 | 131238 | None | V2 10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded
and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti
tions by cutting a chase of appropriate width with chase cutter and embed
ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3455.57 | 3455.57 | 10.0 | False | None | None | False | None | False | 34555.7 | 0 | 3610237 | 131238 | None | V2 13.28 | Providing and fixing PTMT extension nipple for water tank pipe, fittings
of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 79.3 | 79.3 | 70.0 | False | None | None | False | None | False | 5551.0 | 0 | 3610238 | 131238 | None | 14.36.1 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of
approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g
"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 111.51 | 111.51 | 23.0 | False | None | None | False | None | False | 2564.73 | 0 | 3610239 | 131238 | None | 14.37.1 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective
length of tail pipe 260 mm from the centre of the waste coupling, 77 mm
breadth with 25 mm minimum water seal, weighing not less than 260 g"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Unit | 379.13 | 379.13 | 23.0 | False | None | None | False | None | False | 8719.99 | 0 | 3610240 | 131238 | None | 13.8.1.1 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 102.84 | 102.84 | 23.0 | False | None | None | False | None | False | 2365.32 | 0 | 3610241 | 131238 | None | 14.22.A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1003.59 | 1003.59 | 23.0 | False | None | None | False | None | False | 23082.57 | 0 | 3610242 | 131238 | None | 13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 768.18 | 768.18 | 53.0 | False | None | None | False | None | False | 40713.54 | 0 | 3610243 | 131238 | None | V2 14.63A | Providing and fixing Single lever sink mixer with swivel spout top
outlet wall mountable made of Stainless steel with all concealed fitting
arrangements & all necessary accesories complete - Class Economy "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4667.31 | 4667.31 | 4.0 | False | None | None | False | None | False | 18669.24 | 0 | 3610244 | 131238 | None | 14.4.1 | Providing and fixing white vitreous china flat back or wall corner type
lipped front urinal basin of 430x260x350 mm and 340x410x265 mm
sizes respectively with automatic flushing cistern with standard flush
pipe and C.P. brass spreaders with brass unions and G.I clamps complete,
including painting of fittings and brackets, cutting and making good the
walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 5518.51 | 5518.51 | 4.0 | False | None | None | False | None | False | 22074.04 | 0 | 3610245 | 131238 | None | ELE 7.3 | Supplying, installation, testing and commissioning of solar hot water
heater comprising of solar Flat Plate Collector (FPC) of size
2120x1040x100mm and stainless steel hot water storage tank with
stainless steel heat exchanger absorber made of copper sheet and
copper tube of following capacity aluminium box collector with
appropriate capacity electrical back up arrangement excluding inlet
and out let pipes. SS Model with 100mm thick of 48Kg/M3 density
Rock wool insulation with 22SWG Aluminium cladding."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 39372.94 | 39372.94 | 3.0 | False | None | None | False | None | False | 118118.82 | 0 | 3610246 | 131238 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-110mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 944.0 | 944.0 | 10.0 | False | None | None | False | None | False | 9440.0 | 0 | 3610247 | 131238 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-75mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 767.0 | 767.0 | 2.0 | False | None | None | False | None | False | 1534.0 | 0 | 3610248 | 131238 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-160MM dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1298.0 | 1298.0 | 1.0 | False | None | None | False | None | False | 1298.0 | 0 | 3610249 | 131238 | None | V-1,P.NO 6,IT.NO 1.4.1 | Earth work excavation by manual means for drains,canals, waste weir,
draft, approach channels, key trenches, foundation of bridges and
such simillar works in all kinds of soils , as per drawing and technical
specifications, including setting out, shoring, strutting, barricading,
caution lights, removal of stumps and other deleterious matter,
excavated surface leveled and sides neatly dressed disposing off the
excavated stuff or sorting & stacking the selected stuff for reuse in a
radius of 50 m and lift upto 1.5 m including cost of labour, tools & other
appurtenaces required to complete the work."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 299.84 | 299.84 | 224.0 | False | None | None | False | None | False | 67164.16 | 0 | 3610250 | 131238 | None | V-1 P.NO 7 IT.NO 1.11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 536.49 | 536.49 | 224.0 | False | None | None | False | None | False | 120173.76 | 0 | 3610251 | 131238 | None | V-5 P.NO 134 IT.NO 10.3 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013
with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of
elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing
the pipes alround to a depth of not less than 15 cms. with soft gravel
or selected earth available from the excavation etc. complete and giving
necessary hydraulic test to the required pressure as per ISS (contractor
will make his own arrangements for procuring water for testing) etc.
complete. for:"
Pipes of SN8 Self Fit - 160mm dia.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 764.46 | 764.46 | 300.0 | False | None | None | False | None | False | 229338.0 | 0 | 3610252 | 131238 | None | V-5 P.NO 134 IT.NO 10.2.4 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ).
- do - 160 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 713.66 | 713.66 | 70.0 | False | None | None | False | None | False | 49956.2 | 0 | 3610253 | 131238 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6757.51 | 6757.51 | 45.0 | False | None | None | False | None | False | 304087.95 | 0 | 3610254 | 131238 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6757.51 | 6757.51 | 15.0 | False | None | None | False | None | False | 101362.65 | 0 | 3610255 | 131238 | None | 13.39 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete
with C.I. grating brick masonry chamber 150 x 100 mm size P type With
Non Modular common burnt clay bricks of designation 3.5 & with water
tight C.I. cover with frame of 300 x300 mm size (inside) the weight of
cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as
per standard design:"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3197.86 | 3197.86 | 25.0 | False | None | None | False | None | False | 79946.5 | 0 | 3610256 | 131238 | None | 16.18 | Construction of RCC Machinehole chambers of 1:1.5:3 proportion
or approved type Cast-insitu / Pre-cast RCC Machinehole chambers,
constructed using form vibrators of standard type, with barricading,
danger lighting and using of sight rails and boning rods wherever
necessary, shoring and strutting wherever required using Ordinary
Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down
graded jelly, well graded sand and steel of approved quality, 200 mm
thick top concrete slab, having wall thickness and raft thickness as in
approved drawings and with an offset in raft alround the chamber as
in approved drawing, benching concrete with 1:6 slope towards the
central drain finished smooth, including fixing and grouting of pipes,
including conveying to work spot supply and fixing SFRC Machinehole
cover and frame (Heavy duty) conforming to IS:12592 with latest
amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3
mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia.
Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as
detailed in Technical specifications, including stone grit beding wherever
required, watering, curing, engraving Machinehole number with flow
direction on the inner cylindrical surface etc., complete including
cost of reinforcement steel and fabrication charges and also cost and
conveyance of all materials, labour with all lead and lifts. The Pre-cast
RCC Machinehole are for various diamters and depths as stated below
and as per detailed drawings, specifications and direction of the Engineer.
For 1.2m dia Machinehole:"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 97246.63 | 97246.63 | 1.0 | False | None | None | False | None | False | 97246.63 | 0 | 3610257 | 131238 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
External & Shafts & Terrace
40mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 80.0 | False | None | None | False | None | False | 47280.0 | 0 | 3610258 | 131238 | None | 13.23 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g)
T.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1665.22 | 1665.22 | 5.0 | False | None | None | False | None | False | 8326.1 | 0 | 3610259 | 131238 | None | 13.40.1 V-5 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 19340.79 | 19340.79 | 2.0 | False | None | None | False | None | False | 38681.58 | 0 | 3610260 | 131238 | None | 13.32 V-5 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and
equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 8053.5 | 8053.5 | 2.0 | False | None | None | False | None | False | 16107.0 | 0 | 3610261 | 131238 | None | PWD ELE SR V-6 IT.NO 2.2.1 | WIRES & CABLES
Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Short point up to 3Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 333.29 | 333.29 | 25.0 | False | None | None | False | None | False | 8332.25 | 0 | 3610262 | 131238 | None | PWD ELE SR V-10 IT.NO 2.2.2 | Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Pack | 469.58 | 469.58 | 36.0 | False | None | None | False | None | False | 16904.88 | 0 | 3610263 | 131238 | None | PWD ELE SR V-11 IT.NO 2.2.3 | Point wiring using Copper wire without switch.
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Long point above 6Mtr up to 10Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 687.65 | 687.65 | 63.0 | False | None | None | False | None | False | 43321.95 | 0 | 3610264 | 131238 | None | PWD ELE SR V-12 IT.NO 2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 838.8 | 838.8 | 8.0 | False | None | None | False | None | False | 6710.4 | 0 | 3610265 | 131238 | None | PWD ELE SR V-14 IT.NO 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
1-3Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 170.98 | 170.98 | 25.0 | False | None | None | False | None | False | 4274.5 | 0 | 3610266 | 131238 | None | PWD ELE SR V-15 IT.NO 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
4-5Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 197.0 | 197.0 | 32.0 | False | None | None | False | None | False | 6304.0 | 0 | 3610267 | 131238 | None | PWD ELE SR V-16 IT.NO 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
6Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 219.3 | 219.3 | 16.0 | False | None | None | False | None | False | 3508.8 | 0 | 3610268 | 131238 | None | PWD ELE SR V-17 IT.NO 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
8 Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 272.58 | 272.58 | 7.0 | False | None | None | False | None | False | 1908.06 | 0 | 3610269 | 131238 | None | PWD ELE SR V-18 IT.NO 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
10-12Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 323.38 | 323.38 | 20.0 | False | None | None | False | None | False | 6467.6 | 0 | 3610270 | 131238 | None | PWD ELE SR V-20 IT.NO 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
1 to 3 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 199.48 | 199.48 | 32.0 | False | None | None | False | None | False | 6383.36 | 0 | 3610271 | 131238 | None | PWD ELE SR V-21 IT.NO 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
4 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 216.83 | 216.83 | 16.0 | False | None | None | False | None | False | 3469.28 | 0 | 3610272 | 131238 | None | PWD ELE SR V-22 IT.NO 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
6 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 289.93 | 289.93 | 7.0 | False | None | None | False | None | False | 2029.51 | 0 | 3610273 | 131238 | None | PWD ELE SR V-23 IT.NO 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
8 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 351.88 | 351.88 | 21.0 | False | None | None | False | None | False | 7389.48 | 0 | 3610274 | 131238 | None | PWD ELE SR V-24 IT.NO 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
10-12 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 426.22 | 426.22 | 31.0 | False | None | None | False | None | False | 13212.82 | 0 | 3610275 | 131238 | None | PWD ELE SR V-26 IT.NO 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps one way Switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 126.38 | 126.38 | 217.0 | False | None | None | False | None | False | 27424.46 | 0 | 3610276 | 131238 | None | PWD ELE SR V-6 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps Two way Switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 205.67 | 205.67 | 2.0 | False | None | None | False | None | False | 411.34 | 0 | 3610277 | 131238 | None | PWD ELE SR V-6,IT.NO 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps 3way socket
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 211.87 | 211.87 | 81.0 | False | None | None | False | None | False | 17161.47 | 0 | 3610278 | 131238 | None | PWD ELE SR V-6,IT.NO 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Stepped Fan Regulator.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 442.32 | 442.32 | 24.0 | False | None | None | False | None | False | 10615.68 | 0 | 3610279 | 131238 | None | PWD ELE SR V-6,IT.NO 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
16Amps one way switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 223.02 | 223.02 | 10.0 | False | None | None | False | None | False | 2230.2 | 0 | 3610280 | 131238 | None | PWD ELE SR V-6, IT.NO 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
32Amps DP switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 403.91 | 403.91 | 15.0 | False | None | None | False | None | False | 6058.65 | 0 | 3610281 | 131238 | None | PWD ELE SR V-6,IT.NO 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6/16Amps universal socket
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 292.4 | 292.4 | 25.0 | False | None | None | False | None | False | 7310.0 | 0 | 3610282 | 131238 | None | PWD ELE SR V-6,IT.NO 1.13 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Supplyin and Fixing Metal Fan Box with Round Hook.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 144.96 | 144.96 | 24.0 | False | None | None | False | None | False | 3479.04 | 0 | 3610283 | 131238 | None | PWD ELE SR V-6,IT.NO-1.2.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
19/20mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 81.77 | 81.77 | 890.0 | False | None | None | False | None | False | 72775.3 | 0 | 3610284 | 131238 | None | PWD ELE SR V-6,IT.NO 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
25mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 96.64 | 96.64 | 1030.0 | False | None | None | False | None | False | 99539.2 | 0 | 3610285 | 131238 | None | PWD ELE SR V-6, IT.NO .2.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
32mm dia 2.5mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 127.62 | 127.62 | 250.0 | False | None | None | False | None | False | 31905.0 | 0 | 3610286 | 131238 | None | PWD ELE SR V-6,IT.NO1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
19/20mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 84.25 | 84.25 | 445.0 | False | None | None | False | None | False | 37491.25 | 0 | 3610287 | 131238 | None | PWD ELE SR V-6,IT.NO-1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 97.88 | 97.88 | 515.0 | False | None | None | False | None | False | 50408.2 | 0 | 3610288 | 131238 | None | PWD ELE SR V-6,IT.NO-1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
32mm dia 2.5mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 122.66 | 122.66 | 150.0 | False | None | None | False | None | False | 18399.0 | 0 | 3610289 | 131238 | None | PWD ELE SR V-6,IT.NO 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 32.21 | 32.21 | 470.0 | False | None | None | False | None | False | 15138.7 | 0 | 3610290 | 131238 | None | PWD ELE SR V-6,IT.NO 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 52.04 | 52.04 | 1530.0 | False | None | None | False | None | False | 79621.2 | 0 | 3610291 | 131238 | None | PWD ELE SR V-6,IT.NO 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
4 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 78.06 | 78.06 | 740.0 | False | None | None | False | None | False | 57764.4 | 0 | 3610292 | 131238 | None | PWD ELE SR V-6,IT.NO 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
6 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 113.99 | 113.99 | 580.0 | False | None | None | False | None | False | 66114.2 | 0 | 3610293 | 131238 | None | PWD ELE SR V-6,IT.NO 5.19.11 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure
III - Double Door
4 Way TP & N
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 5003.08 | 5003.08 | 2.0 | False | None | None | False | None | False | 10006.16 | 0 | 3610294 | 131238 | None | PWD ELE SR V-6,IT.NO 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
6-32Amps SP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 514.19 | 514.19 | 62.0 | False | None | None | False | None | False | 31879.78 | 0 | 3610295 | 131238 | None | PWD ELE SR V-6 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
40Amps TPN
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3771.52 | 3771.52 | 2.0 | False | None | None | False | None | False | 7543.04 | 0 | 3610296 | 131238 | None | PWD ELE SR V-6,IT.NO 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board
16-25 Amps 2 pole
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 5299.2 | 5299.2 | 2.0 | False | None | None | False | None | False | 10598.4 | 0 | 3610297 | 131238 | None | PWD ELE SR V-6,IT.NO 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only)
32mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 480.73 | 480.73 | 10.0 | False | None | None | False | None | False | 4807.3 | 0 | 3610298 | 131238 | None | PWD ELE SR V-6,IT.NO 6.17.8 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.
35 sqmm Long Barrel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 39.65 | 39.65 | 16.0 | False | None | None | False | None | False | 634.4 | 0 | 3610299 | 131238 | None | V-6 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4348.89 | 4348.89 | 7.0 | False | None | None | False | None | False | 30442.23 | 0 | 3610300 | 131238 | None | V-6 12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x3mm GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 101.6 | 101.6 | 100.0 | False | None | None | False | None | False | 10160.0 | 0 | 3610301 | 131238 | None | 12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
600X600X3 GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1084.13 | 1084.13 | 6.0 | False | None | None | False | None | False | 6504.78 | 0 | 3610302 | 131238 | None | 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1096.52 | 1096.52 | 19.0 | False | None | None | False | None | False | 20833.88 | 0 | 3610303 | 131238 | None | 11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1640.44 | 1640.44 | 5.0 | False | None | None | False | None | False | 8202.2 | 0 | 3610304 | 131238 | None | 11.3.2 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 854.91 | 854.91 | 51.0 | False | None | None | False | None | False | 43600.41 | 0 | 3610305 | 131238 | None | 11.11.3 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 184.61 | 184.61 | 15.0 | False | None | None | False | None | False | 2769.15 | 0 | 3610306 | 131238 | None | PWD ELE SR V-6,IT.NO 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1848.59 | 1848.59 | 13.0 | False | None | None | False | None | False | 24031.67 | 0 | 3610307 | 131238 | None | PWD ELE SR V-6,IT.NO 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3316.8 | 3316.8 | 24.0 | False | None | None | False | None | False | 79603.2 | 0 | 3610308 | 131238 | None | PWD ELE SR V-6,IT.NO 13.11 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.
On wall / ceiling / Rafter / Girders
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 390.29 | 390.29 | 24.0 | False | None | None | False | None | False | 9366.96 | 0 | 3610309 | 131238 | None | PWD ELE SR V-6,IT.NO 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 151.16 | 151.16 | 83.0 | False | None | None | False | None | False | 12546.28 | 0 | 3610310 | 131238 | None | PWD ELE SR V-6,IT.NO 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 875.97 | 875.97 | 13.0 | False | None | None | False | None | False | 11387.61 | 0 | 3610311 | 131238 | None | PWD ELE SR V-6,IT.NO 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 200.72 | 200.72 | 3.0 | False | None | None | False | None | False | 602.16 | 0 | 3610312 | 131238 | None | PWD ELE SR V-6,IT.NO 5.42.1 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete
16SWG
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 86000.0 | False | None | None | False | None | False | 45580.0 | 0 | 3610313 | 131238 | None | PWD ELE SR V-6,IT.NO 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 4255.97 | 4255.97 | 5.0 | False | None | None | False | None | False | 21279.85 | 0 | 3610314 | 131238 | None | PWD ELE SR V-6,IT.NO 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
40x40x6mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 377.9 | 377.9 | 10.0 | False | None | None | False | None | False | 3779.0 | 0 | 3610315 | 131238 | None | PWD ELE SR V-6,IT.NO 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
50x100x50x6mm C channel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 936.68 | 936.68 | 10.0 | False | None | None | False | None | False | 9366.8 | 0 | 3610316 | 131238 | None | PWD ELE SR V-6,IT.NO 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs)
100Amps 25kA
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 10515.39 | 10515.39 | 1.0 | False | None | None | False | None | False | 10515.39 | 0 | 3610317 | 131238 | None | PWD ELE SR V-6,iT.NO 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
50-63Amps DP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3826.03 | 3826.03 | 10.0 | False | None | None | False | None | False | 38260.3 | 0 | 3610318 | 131238 | None | PWD ELE SR V-6,IT.NO 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 11541.29 | 11541.29 | 1.0 | False | None | None | False | None | False | 11541.29 | 0 | 3610319 | 131238 | None | PWD ELE SR V-6,IT.NO 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3610320 | 131238 | None | PWD ELE SR V-6,IT.NO 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 696.32 | 696.32 | 3.0 | False | None | None | False | None | False | 2088.96 | 0 | 3610321 | 131238 | None | PWD ELE SR V-6,IT.NO5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kvar | 594.72 | 594.72 | 15.0 | False | None | None | False | None | False | 8920.8 | 0 | 3610322 | 131238 | None | 5.19.9 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2885.63 | 2885.63 | 2.0 | False | None | None | False | None | False | 5771.26 | 0 | 3610323 | 131238 | None | 5.19.12 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6120.66 | 6120.66 | 1.0 | False | None | None | False | None | False | 6120.66 | 0 | 3610324 | 131238 | None | 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3826.03 | 3826.03 | 1.0 | False | None | None | False | None | False | 3826.03 | 0 | 3610325 | 131238 | None | 5.20.8 | Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6377.13 | 6377.13 | 3.0 | False | None | None | False | None | False | 19131.39 | 0 | 3610326 | 131238 | None | 32.05 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 109549.9 | 109549.9 | 0.1 | False | None | None | False | None | False | 10954.99 | 0 | 3610327 | 131238 | None | 32.09 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 190882.82 | 190882.82 | 0.05 | False | None | None | False | None | False | 9544.141 | 0 | 3610328 | 131238 | None | 32.13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 393892.97 | 393892.97 | 0.1 | False | None | None | False | None | False | 39389.297 | 0 | 3610329 | 131238 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 25877.75 | 25877.75 | 0.05 | False | None | None | False | None | False | 1293.8875 | 0 | 3610330 | 131238 | None | 31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 38581.22 | 38581.22 | 0.2 | False | None | None | False | None | False | 7716.244 | 0 | 3610331 | 131238 | None | 6.17.6 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 15.41 | 15.41 | 20.0 | False | None | None | False | None | False | 308.2 | 0 | 3610332 | 131238 | None | 16.17.10 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 148.68 | 148.68 | 16.0 | False | None | None | False | None | False | 2378.88 | 0 | 3610333 | 131238 | None | 11.11.5 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 333.29 | 333.29 | 9.0 | False | None | None | False | None | False | 2999.61 | 0 | 3610334 | 131238 | None | 11.6.3 | Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 5641.17 | 5641.17 | 8.0 | False | None | None | False | None | False | 45129.36 | 0 | 3610335 | 131238 | None | 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4985.74 | 4985.74 | 2.0 | False | None | None | False | None | False | 9971.48 | 0 | 3610336 | 131238 | None | 13.4.1 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1810.18 | 1810.18 | 3.0 | False | None | None | False | None | False | 5430.54 | 0 | 3610337 | 131238 | None | 5.14.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 2738.19 | 2738.19 | 2.0 | False | None | None | False | None | False | 5476.38 | 0 | 3610338 | 131238 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 169.74 | 169.74 | 24.0 | False | None | None | False | None | False | 4073.76 | 0 | 3610339 | 131238 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 395.24 | 395.24 | 31.0 | False | None | None | False | None | False | 12252.44 | 0 | 3610340 | 131238 | None | 2.2.5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 1225.37 | 1225.37 | 4.0 | False | None | None | False | None | False | 4901.48 | 0 | 3610341 | 131238 | None | 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 144.96 | 144.96 | 6.0 | False | None | None | False | None | False | 869.76 | 0 | 3610342 | 131238 | None | 12.46 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 78.06 | 78.06 | 21.0 | False | None | None | False | None | False | 1639.26 | 0 | 3610343 | 131238 | None | 3.6.11 | TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 193.28 | 193.28 | 2.0 | False | None | None | False | None | False | 386.56 | 0 | 3610344 | 131238 | None | 12.2.1 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 304.79 | 304.79 | 1.0 | False | None | None | False | None | False | 304.79 | 0 | 3610345 | 131238 | None | 32.02 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 98168.45 | 98168.45 | 0.1 | False | None | None | False | None | False | 9816.845 | 0 | 3610346 | 131238 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 25877.75 | 25877.75 | 0.1 | False | None | None | False | None | False | 2587.775 | 0 | 3610347 | 131238 | None | pwd sr | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 15.41 | 15.41 | 15.0 | False | None | None | False | None | False | 231.15 | 0 | 3610348 | 131238 | None | 11..11.7 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 527.81 | 527.81 | 3.0 | False | None | None | False | None | False | 1583.43 | 0 | 3610349 | 131238 | None | 12.27 | Supplying & Fixing of Special Type pigmy and candle lamp.
Operating voltage range from 180V to 265V, 50Hz AC power Supply"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 64.43 | 64.43 | 2.0 | False | None | None | False | None | False | 128.86 | 0 | 3610350 | 131238 | None | 11.8.1 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3004.58 | 3004.58 | 1.0 | False | None | None | False | None | False | 3004.58 | 0 | 3610351 | 131238 | None | 5.7.2 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 298.6 | 298.6 | 1.0 | False | None | None | False | None | False | 298.6 | 0 | 3610352 | 131238 | None | 5.30 | Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1709.82 | 1709.82 | 1.0 | False | None | None | False | None | False | 1709.82 | 0 | 3610353 | 131238 | None | 7.1.3 | Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 12689.84 | 12689.84 | 1.0 | False | None | None | False | None | False | 12689.84 | 0 | 3610354 | 131238 | None | PWD SR 2023-24 Volume 6 It No-9.3.3 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 84726.54 | 84726.54 | 1.0 | False | None | None | False | None | False | 84726.54 | 0 | 3610355 | 131238 | None | PWD SR 2023-24 Volume 6 It No-9.5.9 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 19693.91 | 19693.91 | 4.0 | False | None | None | False | None | False | 78775.64 | 0 | 3610356 | 131238 | None | A.R | Item Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 300000.0 | 300000.0 | 1.0 | False | None | None | False | None | False | 300000.0 | 0 | 3610357 | 131238 | None | LQR | IP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 23836.0 | 23836.0 | 4.0 | False | None | None | False | None | False | 95344.0 | 0 | 3610358 | 131238 | None | LQR | IP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 25606.0 | 25606.0 | 2.0 | False | None | None | False | None | False | 51212.0 | 0 | 3610359 | 131238 | None | LQR | Supplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3610360 | 131238 | None | LQR | Supply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 17110.0 | 17110.0 | 2.0 | False | None | None | False | None | False | 34220.0 | 0 | 3610361 | 131238 | None | LQR | Supply and Installation of I/Os
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 147.5 | 147.5 | 12.0 | False | None | None | False | None | False | 1770.0 | 0 | 3610362 | 131238 | None | LQR | Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 265.5 | 265.5 | 12.0 | False | None | None | False | None | False | 3186.0 | 0 | 3610363 | 131238 | None | LQR | Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 336.3 | 336.3 | 6.0 | False | None | None | False | None | False | 2017.8 | 0 | 3610364 | 131238 | None | LQR | Supply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3610365 | 131238 | None | V-6 8.1 | Supplying and drawing UTP-CAT 6E LAN cable
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 47.08 | 47.08 | 600.0 | False | None | None | False | None | False | 28248.0 | 0 | 3610366 | 131238 | None | 1.2.2 | Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 96.64 | 96.64 | 500.0 | False | None | None | False | None | False | 48320.0 | 0 | 3610367 | 131238 | None | 8.12.3 | Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3778.95 | 3778.95 | 1.0 | False | None | None | False | None | False | 3778.95 | 0 | 3610368 | 131238 | None | 8.4.1 v-6 | Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 6061.19 | 6061.19 | 1.0 | False | None | None | False | None | False | 6061.19 | 0 | 3610369 | 131238 | None | 1.01 | Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 8767.16 | 8767.16 | 8.0 | False | None | None | False | None | False | 70137.28 | 0 | 3610370 | 131238 | None | 2.02 | Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 1379.01 | 1379.01 | 8.0 | False | None | None | False | None | False | 11032.08 | 0 | 3610371 | 131238 | None | 6.05 | Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 107.79 | 107.79 | 6.0 | False | None | None | False | None | False | 646.74 | 0 | 3610372 | 131238 | None | 13.12 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 59.47 | 59.47 | 6.0 | False | None | None | False | None | False | 356.82 | 0 | 3610373 | 131238 | None | 2.16 | Supply of Spiral Earth Electrode
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 296.12 | 296.12 | 11.0 | False | None | None | False | None | False | 3257.32 | 0 | 3610374 | 131238 | None | 2.16 | Erection of Spiral Earth Electrode
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 115.23 | 115.23 | 11.0 | False | None | None | False | None | False | 1267.53 | 0 | 3610375 | 131238 | None | 68.17 | Supply and fixing of Caution/Danger Board
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 185.85 | 185.85 | 6.0 | False | None | None | False | None | False | 1115.1 | 0 | 3610376 | 131238 | None | 4.02 | Supply of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 110.27 | 110.27 | 8.0 | False | None | None | False | None | False | 882.16 | 0 | 3610377 | 131238 | None | 5.09 | Erection of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 52.04 | 52.04 | 8.0 | False | None | None | False | None | False | 416.32 | 0 | 3610378 | 131238 | None | 24.05 | Supply and fixing of 11 kV, 400 Amps Double Break GOS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 26341.14 | 26341.14 | 1.0 | False | None | None | False | None | False | 26341.14 | 0 | 3610379 | 131238 | None | 24.07 | Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 7521.97 | 7521.97 | 1.0 | False | None | None | False | None | False | 7521.97 | 0 | 3610380 | 131238 | None | 25.01 | Supply of DOLO Cut Out
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set of 3 Nos | 7279.13 | 7279.13 | 1.0 | False | None | None | False | None | False | 7279.13 | 0 | 3610381 | 131238 | None | 13.01 | Erection of DOLO Cut Out
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set of 3 Nos | 293.64 | 293.64 | 1.0 | False | None | None | False | None | False | 293.64 | 0 | 3610382 | 131238 | None | 13.07 | Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 210958.34 | 210958.34 | 1.0 | False | None | None | False | None | False | 210958.34 | 0 | 3610383 | 131238 | None | 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 4348.89 | 4348.89 | 8.0 | False | None | None | False | None | False | 34791.12 | 0 | 3610384 | 131238 | None | 12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | MT | 158.59 | 158.59 | 100.0 | False | None | None | False | None | False | 15859.0 | 0 | 3610385 | 131238 | None | 12.58.9 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 2035.68 | 2035.68 | 100.0 | False | None | None | False | None | False | 203568.0 | 0 | 3610386 | 131238 | None | 12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 9194.62 | 9194.62 | 10.0 | False | None | None | False | None | False | 91946.2 | 0 | 3610387 | 131238 | None | 45.07 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 5039.01 | 5039.01 | 4.0 | False | None | None | False | None | False | 20156.04 | 0 | 3610388 | 131238 | None | 45.04 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 3887.98 | 3887.98 | 2.0 | False | None | None | False | None | False | 7775.96 | 0 | 3610389 | 131238 | None | 36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 1102296.17 | 1102296.17 | 0.1 | False | None | None | False | None | False | 110229.617 | 0 | 3610390 | 131238 | None | 38. | Providing chain link fencing 50 mm size of 8 guage properly stretched between
rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be
welded to the Pole and block pipe at top and bottom as required including cost
of all materials, labour, lead and lifts, cutting, bending wherever necessary,
wastage and lapping etc., complete as per the direction of the engineer
incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1222.89 | 1222.89 | 150.0 | False | None | None | False | None | False | 183433.5 | 0 | 3610391 | 131238 | None | 5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 176000.0 | False | None | None | False | None | False | 93280.0 | 0 | 3610392 | 131238 | None | 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 4255.97 | 4255.97 | 6.0 | False | None | None | False | None | False | 25535.82 | 0 | 3610393 | 131238 | None | 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 377.9 | 377.9 | 12.0 | False | None | None | False | None | False | 4534.8 | 0 | 3610394 | 131238 | None | 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 936.68 | 936.68 | 12.0 | False | None | None | False | None | False | 11240.16 | 0 | 3610395 | 131238 | None | 5.15.15 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 29172.26 | 29172.26 | 1.0 | False | None | None | False | None | False | 29172.26 | 0 | 3610396 | 131238 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3610397 | 131238 | None | 10.1.3 | Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have +
1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating
lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting
battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr
at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 558914.14 | 558914.14 | 1.0 | False | None | None | False | None | False | 558914.14 | 0 | 3610398 | 131238 | None | 10.2.2 | Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the
accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 72742.93 | 72742.93 | 1.0 | False | None | None | False | None | False | 72742.93 | 0 | 3610399 | 131238 | None | A.R | Supply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 3540.0 | 3540.0 | 5.0 | False | None | None | False | None | False | 17700.0 | 0 | 3610400 | 131238 | None | A.R | Supply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 236.0 | 236.0 | 50.0 | False | None | None | False | None | False | 11800.0 | 0 | 3610401 | 131238 | None | 58.02 | LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 98973.8 | 98973.8 | 1.0 | False | None | None | False | None | False | 98973.8 | 0 | 3610402 | 131238 | None | 53.01 | CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 24302.99 | 24302.99 | 1.0 | False | None | None | False | None | False | 24302.99 | 0 | 3610403 | 131238 | None | 10.01 | Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 173.46 | 173.46 | 15.0 | False | None | None | False | None | False | 2601.9 | 0 | 3610404 | 131238 | None | v-6 2.02 | Supply of 11 kV, Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr
Long, 145 Kg WL"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 603.39 | 603.39 | 6.0 | False | None | None | False | None | False | 3620.34 | 0 | 3610405 | 131238 | None | v-6 2.02 | Erection of 11 kV, Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr
Long, 145 Kg WL"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 318.42 | 318.42 | 6.0 | False | None | None | False | None | False | 1910.52 | 0 | 3610406 | 131238 | None | v-6 6.06 | Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP
Rod) "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 254.0 | 254.0 | 18.0 | False | None | None | False | None | False | 4572.0 | 0 | 3610407 | 131238 | None | v-6 6.10 | Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 235.45 | 235.45 | 18.0 | False | None | None | False | None | False | 4238.1 | 0 | 3610408 | 131238 | None | 13.12 v-6 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 59.47 | 59.47 | 18.0 | False | None | None | False | None | False | 1070.46 | 0 | 3610409 | 131238 | None | v-6 6.08 | Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 73.1 | 73.1 | 4.0 | False | None | None | False | None | False | 292.4 | 0 | 3610410 | 131238 | None | 7.02 | Supply of Rabbit ACSR Conductor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 57283.93 | 57283.93 | 1.0 | False | None | None | False | None | False | 57283.93 | 0 | 3610411 | 131238 | None | 6.02 V-6 | Erection of Rabbit ACSR Conductor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 5403.28 | 5403.28 | 1.0 | False | None | None | False | None | False | 5403.28 | 0 |
| 1721828234000 | 0 | None | None | Buildings | TINTHANI IN SHORAPUR TALUK OF YADGIR DISTRICT | 34741282.93 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3610412 | 131239 | None | CSR:V-3 PAGE NO 9 Itm 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | 100 Sqm | 486.93 | 486.93 | 17.49 | False | None | None | False | None | False | 8516.4057 | 0 | 3610413 | 131239 | None | V-1 page 8 itm 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 117.71 | 117.71 | 768.64 | False | None | None | False | None | False | 90476.6144 | 0 | 3610414 | 131239 | None | V-1page 8 itm 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 126.38 | 126.38 | 1311.57 | False | None | None | False | None | False | 165756.2166 | 0 | 3610415 | 131239 | None | V-1page 8 itm 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 449.76 | 449.76 | 230.53 | False | None | None | False | None | False | 103683.1728 | 0 | 3610416 | 131239 | None | V-3page 3 A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 167.27 | 167.27 | 225.13 | False | None | None | False | None | False | 37657.4951 | 0 | 3610417 | 131239 | None | V-2page5 itm 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 146.2 | 146.2 | 774.16 | False | None | None | False | None | False | 113182.192 | 0 | 3610418 | 131239 | None | V-1pg7 itm1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 329.57 | 329.57 | 807.35 | False | None | None | False | None | False | 266078.3395 | 0 | 3610419 | 131239 | None | V-1page7vitm1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 587.29 | 587.29 | 728.89 | False | None | None | False | None | False | 428069.8081 | 0 | 3610420 | 131239 | None | V-1page 15 itm2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7420.37 | 7420.37 | 161.37 | False | None | None | False | None | False | 1197425.1069 | 0 | 3610421 | 131239 | None | V-1page15 itm 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8478.33 | 8478.33 | 177.95 | False | None | None | False | None | False | 1508718.8235 | 0 | 3610422 | 131239 | None | V-1page16 itm 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8635.33 | 8635.33 | 13.4 | False | None | None | False | None | False | 115713.422 | 0 | 3610423 | 131239 | None | V-1page15itm 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 14413.41 | 14413.41 | 55.14 | False | None | None | False | None | False | 794755.4274 | 0 | 3610424 | 131239 | None | V-3page135itm15.4 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 252.76 | 252.76 | 13.0 | False | None | None | False | None | False | 3285.88 | 0 | 3610425 | 131239 | None | V-2page55 itm 8.16.a | Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1533.88 | 1533.88 | 13.81 | False | None | None | False | None | False | 21182.8828 | 0 | 3610426 | 131239 | None | V-1page18itm2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Tonne | 110837.22 | 110837.22 | 50.82 | False | None | None | False | None | False | 5632747.5204 | 0 | 3610427 | 131239 | None | 18-19SR ITM4.21 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 38.94 | 38.94 | 145.02 | False | None | None | False | None | False | 5647.0788 | 0 | 3610428 | 131239 | None | DATA RATE | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 86.14 | 86.14 | 145.02 | False | None | None | False | None | False | 12492.0228 | 0 | 3610429 | 131239 | None | V-2PAGE 9 ITM5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7915.97 | 7915.97 | 8.76 | False | None | None | False | None | False | 69343.8972 | 0 | 3610430 | 131239 | None | V-2PAGE 14 ITM 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1623.09 | 1623.09 | 1313.93 | False | None | None | False | None | False | 2132626.6437 | 0 | 3610431 | 131239 | None | V-2page 14 itm 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks
of size 400x100x200mm having block density more than 1800kg/m3
and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005
including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1367.86 | 1367.86 | 171.24 | False | None | None | False | None | False | 234232.3464 | 0 | 3610432 | 131239 | None | V-2 page100 itm 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 122431.79 | 122431.79 | 1.2 | False | None | None | False | None | False | 146918.148 | 0 | 3610433 | 131239 | None | V-2 page 105 itm 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 1258.82 | 1258.82 | 32.0 | False | None | None | False | None | False | 40282.24 | 0 | 3610434 | 131239 | None | 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 681.45 | 681.45 | 64.0 | False | None | None | False | None | False | 43612.8 | 0 | 3610435 | 131239 | None | 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 464.63 | 464.63 | 32.0 | False | None | None | False | None | False | 14868.16 | 0 | 3610436 | 131239 | None | 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 185.85 | 185.85 | 64.0 | False | None | None | False | None | False | 11894.4 | 0 | 3610437 | 131239 | None | 22.15.9 | PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 86.73 | 86.73 | 128.0 | False | None | None | False | None | False | 11101.44 | 0 | 3610438 | 131239 | None | 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 123.9 | 123.9 | 32.0 | False | None | None | False | None | False | 3964.8 | 0 | 3610439 | 131239 | None | 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 1303.43 | 1303.43 | 32.0 | False | None | None | False | None | False | 41709.76 | 0 | 3610440 | 131239 | None | V-2page69 itm 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 74.34 | 74.34 | 192.0 | False | None | None | False | None | False | 14273.28 | 0 | 3610441 | 131239 | None | 20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 64.43 | 64.43 | 168.45 | False | None | None | False | None | False | 10853.2335 | 0 | 3610442 | 131239 | None | V-2page105 itm 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4115.96 | 4115.96 | 74.84 | False | None | None | False | None | False | 308038.4464 | 0 | 3610443 | 131239 | None | V-2page109 itm 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 8343.43 | 8343.43 | 69.39 | False | None | None | False | None | False | 578950.6077 | 0 | 3610444 | 131239 | None | V-2page109 itm 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 7085.84 | 7085.84 | 6.84 | False | None | None | False | None | False | 48467.1456 | 0 | 3610445 | 131239 | None | V-2page 86itm11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 208.15 | 208.15 | 1600.83 | False | None | None | False | None | False | 333212.7645 | 0 | 3610446 | 131239 | None | V-2page 111itm 12.93.1 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/
cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | m | 869.78 | 869.78 | 64.35 | False | None | None | False | None | False | 55970.343 | 0 | 3610447 | 131239 | None | V-2page84 itm 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kgs | 168.5 | 168.5 | 1724.91 | False | None | None | False | None | False | 290647.335 | 0 | 3610448 | 131239 | None | V-2page 41itm 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 386.57 | 386.57 | 1763.82 | False | None | None | False | None | False | 681839.8974 | 0 | 3610449 | 131239 | None | V-2page 43 itm 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 261.43 | 261.43 | 1176.83 | False | None | None | False | None | False | 307658.6669 | 0 | 3610450 | 131239 | None | V-2page50 itm 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 123.9 | 123.9 | 2919.03 | False | None | None | False | None | False | 361667.817 | 0 | 3610451 | 131239 | None | V-2page42itm 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 432.41 | 432.41 | 975.48 | False | None | None | False | None | False | 421807.3068 | 0 | 3610452 | 131239 | None | V-2page41 itm 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 438.61 | 438.61 | 163.05 | False | None | None | False | None | False | 71515.3605 | 0 | 3610453 | 131239 | None | 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 47.08 | 47.08 | 2013.85 | False | None | None | False | None | False | 94812.058 | 0 | 3610454 | 131239 | None | 10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 254.88 | 254.88 | 13.0 | False | None | None | False | None | False | 3313.44 | 0 | 3610455 | 131239 | None | V-2page 54itm 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 64.43 | 64.43 | 628.05 | False | None | None | False | None | False | 40465.2615 | 0 | 3610456 | 131239 | None | V-2page61itm 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1455.83 | 1455.83 | 580.89 | False | None | None | False | None | False | 845677.0887 | 0 | 3610457 | 131239 | None | V-2page59 itm9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 991.2 | 991.2 | 71.5 | False | None | None | False | None | False | 70870.8 | 0 | 3610458 | 131239 | None | V-2page63 itm 9.32 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3199.1 | 3199.1 | 34.54 | False | None | None | False | None | False | 110496.914 | 0 | 3610459 | 131239 | None | V-2page 4 itm 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 365.51 | 365.51 | 316.07 | False | None | None | False | None | False | 115526.7457 | 0 | 3610460 | 131239 | None | V-2page 60 itm 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1101.47 | 1101.47 | 59.14 | False | None | None | False | None | False | 65140.9358 | 0 | 3610461 | 131239 | None | V-2page65 itmv9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1795.31 | 1795.31 | 259.57 | False | None | None | False | None | False | 466008.6167 | 0 | 3610462 | 131239 | None | V-2 page85 itm11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 700.04 | 700.04 | 357.82 | False | None | None | False | None | False | 250488.3128 | 0 | 3610463 | 131239 | None | V-2 page 48itm 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 157.35 | 157.35 | 2741.14 | False | None | None | False | None | False | 431318.379 | 0 | 3610464 | 131239 | None | V-2page 46itm8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 193.28 | 193.28 | 759.66 | False | None | None | False | None | False | 146827.0848 | 0 | 3610465 | 131239 | None | V-2page47 itm8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 61.95 | 61.95 | 96.21 | False | None | None | False | None | False | 5960.2095 | 0 | 3610466 | 131239 | None | V-2page48 itm 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 142.49 | 142.49 | 76.23 | False | None | None | False | None | False | 10862.0127 | 0 | 3610467 | 131239 | None | V-2page47itm 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 65.67 | 65.67 | 179.6 | False | None | None | False | None | False | 11794.332 | 0 | 3610468 | 131239 | None | 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 838.8 | 838.8 | 179.6 | False | None | None | False | None | False | 150648.48 | 0 | 3610469 | 131239 | None | V-2page64itm 9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 2044.35 | 2044.35 | 17.32 | False | None | None | False | None | False | 35408.142 | 0 | 3610470 | 131239 | None | V-2page77 itm 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 5548.24 | 5548.24 | 5.25 | False | None | None | False | None | False | 29128.26 | 0 | 3610471 | 131239 | None | 15.12 | Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1443.44 | 1443.44 | 726.5 | False | None | None | False | None | False | 1048659.16 | 0 | 3610472 | 131239 | None | V-2PAGE22 ITM 7.17 | Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 411.35 | 411.35 | 24.74 | False | None | None | False | None | False | 10176.799 | 0 | 3610473 | 131239 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 102.35 | False | None | None | False | None | False | 1301658.642 | 0 | 3610474 | 131239 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 13565.56 | 13565.56 | 51.01 | False | None | None | False | None | False | 691979.2156 | 0 | 3610475 | 131239 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 115.4 | False | None | None | False | None | False | 1467624.888 | 0 | 3610476 | 131239 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 7.07 | False | None | None | False | None | False | 89914.2804 | 0 | 3610477 | 131239 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 13565.56 | 13565.56 | 12.12 | False | None | None | False | None | False | 164414.5872 | 0 | 3610478 | 131239 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 11911.13 | 11911.13 | 14.18 | False | None | None | False | None | False | 168899.8234 | 0 | 3610479 | 131239 | None | 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4317.92 | 4317.92 | 20.48 | False | None | None | False | None | False | 88431.0016 | 0 | 3610480 | 131239 | None | 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 141.25 | 141.25 | 36.0 | False | None | None | False | None | False | 5085.0 | 0 | 3610481 | 131239 | None | 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1642.91 | 1642.91 | 56.5 | False | None | None | False | None | False | 92824.415 | 0 | 3610482 | 131239 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 6601.39 | 6601.39 | 30.54 | False | None | None | False | None | False | 201606.4506 | 0 | 3610483 | 131239 | None | 10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4877.94 | 4877.94 | 9.69 | False | None | None | False | None | False | 47267.2386 | 0 | 3610484 | 131239 | None | 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 761.99 | 761.99 | 92.01 | False | None | None | False | None | False | 70110.6999 | 0 | 3610485 | 131239 | None | 8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 350.64 | 350.64 | 215.82 | False | None | None | False | None | False | 75675.1248 | 0 | 3610486 | 131239 | None | 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 360.55 | 360.55 | 68.92 | False | None | None | False | None | False | 24849.106 | 0 | 3610487 | 131239 | None | 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3533.63 | 3533.63 | 11.09 | False | None | None | False | None | False | 39187.9567 | 0 | 3610488 | 131239 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 6601.39 | 6601.39 | 13.73 | False | None | None | False | None | False | 90637.0847 | 0 | 3610489 | 131239 | None | 10.1.1 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4963.43 | 4963.43 | 3.81 | False | None | None | False | None | False | 18910.6683 | 0 | 3610490 | 131239 | None | 1.4.1 V-1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 299.84 | 299.84 | 11.06 | False | None | None | False | None | False | 3316.2304 | 0 | 3610491 | 131239 | None | 1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 320.9 | 320.9 | 1.7 | False | None | None | False | None | False | 545.53 | 0 | 3610492 | 131239 | None | 17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1391.4 | 1391.4 | 7.0 | False | None | None | False | None | False | 9739.8 | 0 | 3610493 | 131239 | None | 17.1 V-2 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1241.48 | 1241.48 | 0.28 | False | None | None | False | None | False | 347.6144 | 0 | 3610494 | 131239 | None | 17.2 V-2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1469.45 | 1469.45 | 0.14 | False | None | None | False | None | False | 205.723 | 0 | 3610495 | 131239 | None | 17. V-2 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1476.89 | 1476.89 | 0.14 | False | None | None | False | None | False | 206.7646 | 0 | 3610496 | 131239 | None | 17.4 V-2 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1659.02 | 1659.02 | 0.14 | False | None | None | False | None | False | 232.2628 | 0 | 3610497 | 131239 | None | 17.14 V-2 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1449.63 | 1449.63 | 1.0 | False | None | None | False | None | False | 1449.63 | 0 | 3610498 | 131239 | None | V3 305.3.4 | Compacting Original Ground
Compacting original ground supporting embankment
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 130.1 | 130.1 | 72.0 | False | None | None | False | None | False | 9367.2 | 0 | 3610499 | 131239 | None | V-3 4.2 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 2922.8 | 2922.8 | 36.0 | False | None | None | False | None | False | 105220.8 | 0 | 3610500 | 131239 | None | V3 6.1 ISSUE RATE | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 6095.88 | 6095.88 | 24.0 | False | None | None | False | None | False | 146301.12 | 0 | 3610501 | 131239 | None | V-3 6.2 ISSUE RATE | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 11107.64 | 11107.64 | 48.0 | False | None | None | False | None | False | 533166.72 | 0 | 3610502 | 131239 | None | V-3 8.10 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 105.32 | 105.32 | 15.0 | False | None | None | False | None | False | 1579.8 | 0 | 3610503 | 131239 | None | V-3 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 87.97 | 87.97 | 448.0 | False | None | None | False | None | False | 39410.56 | 0 | 3610504 | 131239 | None | V-314621A | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)
300 x 250 x 100 mm Kerb Stone
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 296.12 | 296.12 | 150.0 | False | None | None | False | None | False | 44418.0 | 0 | 3610505 | 131239 | None | 2.1.4 V-1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7702.86 | 7702.86 | 2.0 | False | None | None | False | None | False | 15405.72 | 0 | 3610506 | 131239 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 9156.76 | 9156.76 | 10.8 | False | None | None | False | None | False | 98893.008 | 0 | 3610507 | 131239 | None | 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 459.67 | 459.67 | 320.0 | False | None | None | False | None | False | 147094.4 | 0 | 3610508 | 131239 | None | 8.31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 220.54 | 220.54 | 320.0 | False | None | None | False | None | False | 70572.8 | 0 | 3610509 | 131239 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8761.09 | 8761.09 | 9.36 | False | None | None | False | None | False | 82003.8024 | 0 | 3610510 | 131239 | None | 8.20 V-3 | Providing and fixing 1.8 m high GI barbed wire fencing with
2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete,
0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 672.78 | 672.78 | 390.0 | False | None | None | False | None | False | 262384.2 | 0 | 3610511 | 131239 | None | V1 1.15.2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 526.58 | 526.58 | 22.51 | False | None | None | False | None | False | 11853.3158 | 0 | 3610512 | 131239 | None | 2.5.2 V1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8732.83 | 8732.83 | 4.32 | False | None | None | False | None | False | 37725.8256 | 0 | 3610513 | 131239 | None | 2.5.2 V1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 9326.32 | 9326.32 | 5.89 | False | None | None | False | None | False | 54932.0248 | 0 | 3610514 | 131239 | None | V2 15.14 | UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 2072.85 | 2072.85 | 36.6 | False | None | None | False | None | False | 75866.31 | 0 | 3610515 | 131239 | None | V5 18.3 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2430.92 | 2430.92 | 8.0 | False | None | None | False | None | False | 19447.36 | 0 | 3610516 | 131239 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 14413.41 | 14413.41 | 9.87 | False | None | None | False | None | False | 142260.3567 | 0 | 3610517 | 131239 | None | 15.5 V-2 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 749.6 | 749.6 | 63.57 | False | None | None | False | None | False | 47652.072 | 0 | 3610518 | 131239 | None | 8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 110.27 | 110.27 | 20.1 | False | None | None | False | None | False | 2216.427 | 0 | 3610519 | 131239 | None | V-5P140I12.4 | Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3610520 | 131239 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3610521 | 131239 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above 50 Mtrs and upto 100 Mtr
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3610522 | 131239 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above100 Mtrs. and upto 150 Mtr
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3610523 | 131239 | None | V-5P143I12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 2394.99 | 2394.99 | 20.0 | False | None | None | False | None | False | 47899.8 | 0 | 3610524 | 131239 | None | V-5P155I13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 681.45 | 681.45 | 150.0 | False | None | None | False | None | False | 102217.5 | 0 | 3610525 | 131239 | None | V-5P143I12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3610526 | 131239 | None | V-5P154I12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3610527 | 131239 | None | 18-19 SR13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3610528 | 131239 | None | V-5P154I13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.
5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 39817.74 | 39817.74 | 1.0 | False | None | None | False | None | False | 39817.74 | 0 | 3610529 | 131239 | None | V-5P155I13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3610530 | 131239 | None | V-5P155I13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3610531 | 131239 | None | V-5P155I13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3610532 | 131239 | None | V-5P156I13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3610533 | 131239 | None | V-5P156I13.33 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 1672.65 | 1672.65 | 1.0 | False | None | None | False | None | False | 1672.65 | 0 | 3610534 | 131239 | None | 2.6.2 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 208.15 | 208.15 | 165.0 | False | None | None | False | None | False | 34344.75 | 0 | 3610535 | 131239 | None | V-5P20I5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete
16 SWG
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3610536 | 131239 | None | V-5P21I5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.
600mmx600mmx170mm.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3610537 | 131239 | None | 5.6.6 V-6 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 404.08 | 404.08 | 1.0 | False | None | None | False | None | False | 404.08 | 0 | 3610538 | 131239 | None | 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 514.19 | 514.19 | 1.0 | False | None | None | False | None | False | 514.19 | 0 | 3610539 | 131239 | None | 13.18.1 | Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 344.44 | 344.44 | 1.0 | False | None | None | False | None | False | 344.44 | 0 | 3610540 | 131239 | None | 5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kvar | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 | 3610541 | 131239 | None | V-2 13.50.5 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work
40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 376.66 | 376.66 | 50.0 | False | None | None | False | None | False | 18833.0 | 0 | 3610542 | 131239 | None | V-2 13.50.6 | Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 478.25 | 478.25 | 20.0 | False | None | None | False | None | False | 9565.0 | 0 | 3610543 | 131239 | None | V-2 13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 358.07 | 358.07 | 185.0 | False | None | None | False | None | False | 66242.95 | 0 | 3610544 | 131239 | None | V-2 13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 477.02 | 477.02 | 120.0 | False | None | None | False | None | False | 57242.4 | 0 | 3610545 | 131239 | None | V-2 IT.NO 13.47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 244.08 | 244.08 | 35.0 | False | None | None | False | None | False | 8542.8 | 0 | 3610546 | 131239 | None | V-2 IT.NO 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 360.55 | 360.55 | 50.0 | False | None | None | False | None | False | 18027.5 | 0 | 3610547 | 131239 | None | V-2 P.NO 128 IT.NO 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 302.32 | 302.32 | 55.0 | False | None | None | False | None | False | 16627.6 | 0 | 3610548 | 131239 | None | V-2 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed
to wooden cleats with C.P. brass screws and washers complete."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1511.58 | 1511.58 | 21.0 | False | None | None | False | None | False | 31743.18 | 0 | 3610549 | 131239 | None | V-2 P.NO 127 IT.NO 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6891.32 | 6891.32 | 4.0 | False | None | None | False | None | False | 27565.28 | 0 | 3610550 | 131239 | None | V-2 P.NO 130 IT.NO 14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 614.54 | 614.54 | 4.0 | False | None | None | False | None | False | 2458.16 | 0 | 3610551 | 131239 | None | V-2 P.NO 123 IT.NO 14.38 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of
the same materials with snap fittings of approved quality and colour,
weighing not less than 105 g"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 179.66 | 179.66 | 4.0 | False | None | None | False | None | False | 718.64 | 0 | 3610552 | 131239 | None | V-2 P.NO 178 IT.NO 14.3.1 | Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush
bend, overflow arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete, including
painting of fittings and brackets, cutting and making good the walls and
floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 7405.5 | 7405.5 | 9.0 | False | None | None | False | None | False | 66649.5 | 0 | 3610553 | 131239 | None | V-2 P.NO 124 IT.NO14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6051.28 | 6051.28 | 10.0 | False | None | None | False | None | False | 60512.8 | 0 | 3610554 | 131239 | None | V-2 P.NO 126 IT.NO 14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6296.6 | 6296.6 | 2.0 | False | None | None | False | None | False | 12593.2 | 0 | 3610555 | 131239 | None | V-2 P.NO 126 IT.NO 14.10.1.1 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per
IS:13983 with C.I. brackets and stainless steel plug 40 mm, including
painting of fittings and brackets, cutting and making good the walls
wherever required : (510x1040 mm bowl depth 250 mm)"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6960.7 | 6960.7 | 4.0 | False | None | None | False | None | False | 27842.8 | 0 | 3610556 | 131239 | None | V-2 13.15 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 898.28 | 898.28 | 12.0 | False | None | None | False | None | False | 10779.36 | 0 | 3610557 | 131239 | None | V-2 P.NO 124 IT.NO 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3818.6 | 3818.6 | 13.0 | False | None | None | False | None | False | 49641.8 | 0 | 3610558 | 131239 | None | V-2 P.NO 120 IT.NO 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 382.85 | 382.85 | 90.0 | False | None | None | False | None | False | 34456.5 | 0 | 3610559 | 131239 | None | V-2 P.NO 120 IT.NO 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 469.58 | 469.58 | 70.0 | False | None | None | False | None | False | 32870.6 | 0 | 3610560 | 131239 | None | V-2 p.NO 120 IT.NO 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
25 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 70.0 | False | None | None | False | None | False | 41370.0 | 0 | 3610561 | 131239 | None | V-2 P.NO 120 IT.NO 13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
32 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 690.12 | 690.12 | 30.0 | False | None | None | False | None | False | 20703.6 | 0 | 3610562 | 131239 | None | V-2 P.NO 120 IT.NO 13.31.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
40 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 664.1 | 664.1 | 20.0 | False | None | None | False | None | False | 13282.0 | 0 | 3610563 | 131239 | None | V-2 P.NO 120IT.NO 13.31.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
50 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 967.66 | 967.66 | 20.0 | False | None | None | False | None | False | 19353.2 | 0 | 3610564 | 131239 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
20mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 268.86 | 268.86 | 50.0 | False | None | None | False | None | False | 13443.0 | 0 | 3610565 | 131239 | None | V-2 P.NO 120 IT.NO 13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
25mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 366.74 | 366.74 | 50.0 | False | None | None | False | None | False | 18337.0 | 0 | 3610566 | 131239 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
40mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 215.0 | False | None | None | False | None | False | 127065.0 | 0 | 3610567 | 131239 | None | V-2 P.NO 120 IT.NO 13.33.7 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
65mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 1734.6 | 1734.6 | 25.0 | False | None | None | False | None | False | 43365.0 | 0 | 3610568 | 131239 | None | V-2 P.NO 120 IT.NO 13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
50mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 893.32 | 893.32 | 40.0 | False | None | None | False | None | False | 35732.8 | 0 | 3610569 | 131239 | None | V2 13.5.2 | Providing and fixing ball valve (brass) of approved quality, High or low
pressure, with plastic floats complete :"
25 mm nominal bore
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 411.35 | 411.35 | 12.0 | False | None | None | False | None | False | 4936.2 | 0 | 3610570 | 131239 | None | V2-13.4 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 32 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 740.92 | 740.92 | 7.0 | False | None | None | False | None | False | 5186.44 | 0 | 3610571 | 131239 | None | V-2 13.4.3 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 40 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 869.78 | 869.78 | 9.0 | False | None | None | False | None | False | 7828.02 | 0 | 3610572 | 131239 | None | v2-13.4.4 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 50 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1059.35 | 1059.35 | 2.0 | False | None | None | False | None | False | 2118.7 | 0 | 3610573 | 131239 | None | V-2,A-13, IT.NO 13.2.1 | Brass bib-cock 15 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 354.35 | 354.35 | 19.0 | False | None | None | False | None | False | 6732.65 | 0 | 3610574 | 131239 | None | V-2 IT.NO 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Ltr | 11.15 | 11.15 | 3000.0 | False | None | None | False | None | False | 33450.0 | 0 | 3610575 | 131239 | None | V2 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 182.13 | 182.13 | 125.0 | False | None | None | False | None | False | 22766.25 | 0 | 3610576 | 131239 | None | Market Rate | Providing and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 177.0 | 177.0 | 55.0 | False | None | None | False | None | False | 9735.0 | 0 | 3610577 | 131239 | None | Market Rate | Air Vent Cowel
75mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 413.0 | 413.0 | 12.0 | False | None | None | False | None | False | 4956.0 | 0 | 3610578 | 131239 | None | Market Rate | Air Vent Cowel
110mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 590.0 | 590.0 | 12.0 | False | None | None | False | None | False | 7080.0 | 0 | 3610579 | 131239 | None | Market Rate | Supplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6844.0 | 6844.0 | 9.0 | False | None | None | False | None | False | 61596.0 | 0 | 3610580 | 131239 | None | Market Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2183.0 | 2183.0 | 9.0 | False | None | None | False | None | False | 19647.0 | 0 | 3610581 | 131239 | None | Market Rate | Supplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 767.0 | 767.0 | 95.0 | False | None | None | False | None | False | 72865.0 | 0 | 3610582 | 131239 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
a) 65mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4130.0 | 4130.0 | 2.0 | False | None | None | False | None | False | 8260.0 | 0 | 3610583 | 131239 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
b) 50mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3304.0 | 3304.0 | 4.0 | False | None | None | False | None | False | 13216.0 | 0 | 3610584 | 131239 | None | V2 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Unit | 345.68 | 345.68 | 4.0 | False | None | None | False | None | False | 1382.72 | 0 | 3610585 | 131239 | None | V2 9.29 | Providing and laying flooring and steps fine dressed granite stone slabs
40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with
cement mortar 1:3 over existing cement concrete bed , including cost
of materials, mortar, labour, curing complete as per specifications."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 5335.13 | 5335.13 | 18.0 | False | None | None | False | None | False | 96032.34 | 0 | 3610586 | 131239 | None | V2 10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded
and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti
tions by cutting a chase of appropriate width with chase cutter and embed
ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3455.57 | 3455.57 | 10.0 | False | None | None | False | None | False | 34555.7 | 0 | 3610587 | 131239 | None | V2 13.28 | Providing and fixing PTMT extension nipple for water tank pipe, fittings
of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 79.3 | 79.3 | 70.0 | False | None | None | False | None | False | 5551.0 | 0 | 3610588 | 131239 | None | 14.36.1 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of
approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g
"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 111.51 | 111.51 | 23.0 | False | None | None | False | None | False | 2564.73 | 0 | 3610589 | 131239 | None | 14.37.1 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective
length of tail pipe 260 mm from the centre of the waste coupling, 77 mm
breadth with 25 mm minimum water seal, weighing not less than 260 g"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Unit | 379.13 | 379.13 | 23.0 | False | None | None | False | None | False | 8719.99 | 0 | 3610590 | 131239 | None | 13.8.1.1 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 102.84 | 102.84 | 23.0 | False | None | None | False | None | False | 2365.32 | 0 | 3610591 | 131239 | None | 14.22.A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1003.59 | 1003.59 | 23.0 | False | None | None | False | None | False | 23082.57 | 0 | 3610592 | 131239 | None | 13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 768.18 | 768.18 | 53.0 | False | None | None | False | None | False | 40713.54 | 0 | 3610593 | 131239 | None | V2 14.63A | Providing and fixing Single lever sink mixer with swivel spout top
outlet wall mountable made of Stainless steel with all concealed fitting
arrangements & all necessary accesories complete - Class Economy "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4667.31 | 4667.31 | 4.0 | False | None | None | False | None | False | 18669.24 | 0 | 3610594 | 131239 | None | 14.4.1 | Providing and fixing white vitreous china flat back or wall corner type
lipped front urinal basin of 430x260x350 mm and 340x410x265 mm
sizes respectively with automatic flushing cistern with standard flush
pipe and C.P. brass spreaders with brass unions and G.I clamps complete,
including painting of fittings and brackets, cutting and making good the
walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 5518.51 | 5518.51 | 4.0 | False | None | None | False | None | False | 22074.04 | 0 | 3610595 | 131239 | None | ELE 7.3 | Supplying, installation, testing and commissioning of solar hot water
heater comprising of solar Flat Plate Collector (FPC) of size
2120x1040x100mm and stainless steel hot water storage tank with
stainless steel heat exchanger absorber made of copper sheet and
copper tube of following capacity aluminium box collector with
appropriate capacity electrical back up arrangement excluding inlet
and out let pipes. SS Model with 100mm thick of 48Kg/M3 density
Rock wool insulation with 22SWG Aluminium cladding."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 39372.94 | 39372.94 | 3.0 | False | None | None | False | None | False | 118118.82 | 0 | 3610596 | 131239 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-110mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 944.0 | 944.0 | 10.0 | False | None | None | False | None | False | 9440.0 | 0 | 3610597 | 131239 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-75mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 767.0 | 767.0 | 2.0 | False | None | None | False | None | False | 1534.0 | 0 | 3610598 | 131239 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-160MM dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1298.0 | 1298.0 | 1.0 | False | None | None | False | None | False | 1298.0 | 0 | 3610599 | 131239 | None | V-1,P.NO 6,IT.NO 1.4.1 | Earth work excavation by manual means for drains,canals, waste weir,
draft, approach channels, key trenches, foundation of bridges and
such simillar works in all kinds of soils , as per drawing and technical
specifications, including setting out, shoring, strutting, barricading,
caution lights, removal of stumps and other deleterious matter,
excavated surface leveled and sides neatly dressed disposing off the
excavated stuff or sorting & stacking the selected stuff for reuse in a
radius of 50 m and lift upto 1.5 m including cost of labour, tools & other
appurtenaces required to complete the work."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 299.84 | 299.84 | 224.0 | False | None | None | False | None | False | 67164.16 | 0 | 3610600 | 131239 | None | V-1 P.NO 7 IT.NO 1.11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 536.49 | 536.49 | 224.0 | False | None | None | False | None | False | 120173.76 | 0 | 3610601 | 131239 | None | V-5 P.NO 134 IT.NO 10.3 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013
with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of
elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing
the pipes alround to a depth of not less than 15 cms. with soft gravel
or selected earth available from the excavation etc. complete and giving
necessary hydraulic test to the required pressure as per ISS (contractor
will make his own arrangements for procuring water for testing) etc.
complete. for:"
Pipes of SN8 Self Fit - 160mm dia.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 764.46 | 764.46 | 300.0 | False | None | None | False | None | False | 229338.0 | 0 | 3610602 | 131239 | None | V-5 P.NO 134 IT.NO 10.2.4 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ).
- do - 160 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 713.66 | 713.66 | 70.0 | False | None | None | False | None | False | 49956.2 | 0 | 3610603 | 131239 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6757.51 | 6757.51 | 45.0 | False | None | None | False | None | False | 304087.95 | 0 | 3610604 | 131239 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6757.51 | 6757.51 | 15.0 | False | None | None | False | None | False | 101362.65 | 0 | 3610605 | 131239 | None | 13.39 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete
with C.I. grating brick masonry chamber 150 x 100 mm size P type With
Non Modular common burnt clay bricks of designation 3.5 & with water
tight C.I. cover with frame of 300 x300 mm size (inside) the weight of
cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as
per standard design:"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3197.86 | 3197.86 | 25.0 | False | None | None | False | None | False | 79946.5 | 0 | 3610606 | 131239 | None | 16.18 | Construction of RCC Machinehole chambers of 1:1.5:3 proportion
or approved type Cast-insitu / Pre-cast RCC Machinehole chambers,
constructed using form vibrators of standard type, with barricading,
danger lighting and using of sight rails and boning rods wherever
necessary, shoring and strutting wherever required using Ordinary
Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down
graded jelly, well graded sand and steel of approved quality, 200 mm
thick top concrete slab, having wall thickness and raft thickness as in
approved drawings and with an offset in raft alround the chamber as
in approved drawing, benching concrete with 1:6 slope towards the
central drain finished smooth, including fixing and grouting of pipes,
including conveying to work spot supply and fixing SFRC Machinehole
cover and frame (Heavy duty) conforming to IS:12592 with latest
amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3
mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia.
Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as
detailed in Technical specifications, including stone grit beding wherever
required, watering, curing, engraving Machinehole number with flow
direction on the inner cylindrical surface etc., complete including
cost of reinforcement steel and fabrication charges and also cost and
conveyance of all materials, labour with all lead and lifts. The Pre-cast
RCC Machinehole are for various diamters and depths as stated below
and as per detailed drawings, specifications and direction of the Engineer.
For 1.2m dia Machinehole:"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 97246.63 | 97246.63 | 1.0 | False | None | None | False | None | False | 97246.63 | 0 | 3610607 | 131239 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
External & Shafts & Terrace
40mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 80.0 | False | None | None | False | None | False | 47280.0 | 0 | 3610608 | 131239 | None | 13.23 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g)
T.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1665.22 | 1665.22 | 5.0 | False | None | None | False | None | False | 8326.1 | 0 | 3610609 | 131239 | None | 13.40.1 V-5 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 19340.79 | 19340.79 | 2.0 | False | None | None | False | None | False | 38681.58 | 0 | 3610610 | 131239 | None | 13.32 V-5 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and
equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 8053.5 | 8053.5 | 2.0 | False | None | None | False | None | False | 16107.0 | 0 | 3610611 | 131239 | None | PWD ELE SR V-6 IT.NO 2.2.1 | WIRES & CABLES
Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Short point up to 3Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 333.29 | 333.29 | 25.0 | False | None | None | False | None | False | 8332.25 | 0 | 3610612 | 131239 | None | PWD ELE SR V-10 IT.NO 2.2.2 | Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Pack | 469.58 | 469.58 | 36.0 | False | None | None | False | None | False | 16904.88 | 0 | 3610613 | 131239 | None | PWD ELE SR V-11 IT.NO 2.2.3 | Point wiring using Copper wire without switch.
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Long point above 6Mtr up to 10Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 687.65 | 687.65 | 63.0 | False | None | None | False | None | False | 43321.95 | 0 | 3610614 | 131239 | None | PWD ELE SR V-12 IT.NO 2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 838.8 | 838.8 | 8.0 | False | None | None | False | None | False | 6710.4 | 0 | 3610615 | 131239 | None | PWD ELE SR V-14 IT.NO 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
1-3Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 170.98 | 170.98 | 25.0 | False | None | None | False | None | False | 4274.5 | 0 | 3610616 | 131239 | None | PWD ELE SR V-15 IT.NO 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
4-5Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 197.0 | 197.0 | 32.0 | False | None | None | False | None | False | 6304.0 | 0 | 3610617 | 131239 | None | PWD ELE SR V-16 IT.NO 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
6Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 219.3 | 219.3 | 16.0 | False | None | None | False | None | False | 3508.8 | 0 | 3610618 | 131239 | None | PWD ELE SR V-17 IT.NO 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
8 Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 272.58 | 272.58 | 7.0 | False | None | None | False | None | False | 1908.06 | 0 | 3610619 | 131239 | None | PWD ELE SR V-18 IT.NO 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
10-12Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 323.38 | 323.38 | 20.0 | False | None | None | False | None | False | 6467.6 | 0 | 3610620 | 131239 | None | PWD ELE SR V-20 IT.NO 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
1 to 3 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 199.48 | 199.48 | 32.0 | False | None | None | False | None | False | 6383.36 | 0 | 3610621 | 131239 | None | PWD ELE SR V-21 IT.NO 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
4 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 216.83 | 216.83 | 16.0 | False | None | None | False | None | False | 3469.28 | 0 | 3610622 | 131239 | None | PWD ELE SR V-22 IT.NO 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
6 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 289.93 | 289.93 | 7.0 | False | None | None | False | None | False | 2029.51 | 0 | 3610623 | 131239 | None | PWD ELE SR V-23 IT.NO 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
8 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 351.88 | 351.88 | 21.0 | False | None | None | False | None | False | 7389.48 | 0 | 3610624 | 131239 | None | PWD ELE SR V-24 IT.NO 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
10-12 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 426.22 | 426.22 | 31.0 | False | None | None | False | None | False | 13212.82 | 0 | 3610625 | 131239 | None | PWD ELE SR V-26 IT.NO 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps one way Switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 126.38 | 126.38 | 217.0 | False | None | None | False | None | False | 27424.46 | 0 | 3610626 | 131239 | None | PWD ELE SR V-6 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps Two way Switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 205.67 | 205.67 | 2.0 | False | None | None | False | None | False | 411.34 | 0 | 3610627 | 131239 | None | PWD ELE SR V-6,IT.NO 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps 3way socket
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 211.87 | 211.87 | 81.0 | False | None | None | False | None | False | 17161.47 | 0 | 3610628 | 131239 | None | PWD ELE SR V-6,IT.NO 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Stepped Fan Regulator.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 442.32 | 442.32 | 24.0 | False | None | None | False | None | False | 10615.68 | 0 | 3610629 | 131239 | None | PWD ELE SR V-6,IT.NO 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
16Amps one way switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 223.02 | 223.02 | 10.0 | False | None | None | False | None | False | 2230.2 | 0 | 3610630 | 131239 | None | PWD ELE SR V-6, IT.NO 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
32Amps DP switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 403.91 | 403.91 | 15.0 | False | None | None | False | None | False | 6058.65 | 0 | 3610631 | 131239 | None | PWD ELE SR V-6,IT.NO 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6/16Amps universal socket
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 292.4 | 292.4 | 25.0 | False | None | None | False | None | False | 7310.0 | 0 | 3610632 | 131239 | None | PWD ELE SR V-6,IT.NO 1.13 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Supplyin and Fixing Metal Fan Box with Round Hook.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 144.96 | 144.96 | 24.0 | False | None | None | False | None | False | 3479.04 | 0 | 3610633 | 131239 | None | PWD ELE SR V-6,IT.NO-1.2.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
19/20mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 81.77 | 81.77 | 890.0 | False | None | None | False | None | False | 72775.3 | 0 | 3610634 | 131239 | None | PWD ELE SR V-6,IT.NO 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
25mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 96.64 | 96.64 | 1030.0 | False | None | None | False | None | False | 99539.2 | 0 | 3610635 | 131239 | None | PWD ELE SR V-6, IT.NO .2.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
32mm dia 2.5mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 127.62 | 127.62 | 250.0 | False | None | None | False | None | False | 31905.0 | 0 | 3610636 | 131239 | None | PWD ELE SR V-6,IT.NO1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
19/20mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 84.25 | 84.25 | 445.0 | False | None | None | False | None | False | 37491.25 | 0 | 3610637 | 131239 | None | PWD ELE SR V-6,IT.NO-1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 97.88 | 97.88 | 515.0 | False | None | None | False | None | False | 50408.2 | 0 | 3610638 | 131239 | None | PWD ELE SR V-6,IT.NO-1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
32mm dia 2.5mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 122.66 | 122.66 | 150.0 | False | None | None | False | None | False | 18399.0 | 0 | 3610639 | 131239 | None | PWD ELE SR V-6,IT.NO 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 32.21 | 32.21 | 470.0 | False | None | None | False | None | False | 15138.7 | 0 | 3610640 | 131239 | None | PWD ELE SR V-6,IT.NO 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 52.04 | 52.04 | 1530.0 | False | None | None | False | None | False | 79621.2 | 0 | 3610641 | 131239 | None | PWD ELE SR V-6,IT.NO 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
4 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 78.06 | 78.06 | 740.0 | False | None | None | False | None | False | 57764.4 | 0 | 3610642 | 131239 | None | PWD ELE SR V-6,IT.NO 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
6 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 113.99 | 113.99 | 580.0 | False | None | None | False | None | False | 66114.2 | 0 | 3610643 | 131239 | None | PWD ELE SR V-6,IT.NO 5.19.11 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure
III - Double Door
4 Way TP & N
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 5003.08 | 5003.08 | 2.0 | False | None | None | False | None | False | 10006.16 | 0 | 3610644 | 131239 | None | PWD ELE SR V-6,IT.NO 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
6-32Amps SP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 514.19 | 514.19 | 62.0 | False | None | None | False | None | False | 31879.78 | 0 | 3610645 | 131239 | None | PWD ELE SR V-6 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
40Amps TPN
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3771.52 | 3771.52 | 2.0 | False | None | None | False | None | False | 7543.04 | 0 | 3610646 | 131239 | None | PWD ELE SR V-6,IT.NO 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board
16-25 Amps 2 pole
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 5299.2 | 5299.2 | 2.0 | False | None | None | False | None | False | 10598.4 | 0 | 3610647 | 131239 | None | PWD ELE SR V-6,IT.NO 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only)
32mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 480.73 | 480.73 | 10.0 | False | None | None | False | None | False | 4807.3 | 0 | 3610648 | 131239 | None | PWD ELE SR V-6,IT.NO 6.17.8 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.
35 sqmm Long Barrel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 39.65 | 39.65 | 16.0 | False | None | None | False | None | False | 634.4 | 0 | 3610649 | 131239 | None | V-6 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4348.89 | 4348.89 | 7.0 | False | None | None | False | None | False | 30442.23 | 0 | 3610650 | 131239 | None | V-6 12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x3mm GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 101.6 | 101.6 | 100.0 | False | None | None | False | None | False | 10160.0 | 0 | 3610651 | 131239 | None | 12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
600X600X3 GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1084.13 | 1084.13 | 6.0 | False | None | None | False | None | False | 6504.78 | 0 | 3610652 | 131239 | None | 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1096.52 | 1096.52 | 19.0 | False | None | None | False | None | False | 20833.88 | 0 | 3610653 | 131239 | None | 11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1640.44 | 1640.44 | 5.0 | False | None | None | False | None | False | 8202.2 | 0 | 3610654 | 131239 | None | 11.3.2 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 854.91 | 854.91 | 51.0 | False | None | None | False | None | False | 43600.41 | 0 | 3610655 | 131239 | None | 11.11.3 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 184.61 | 184.61 | 15.0 | False | None | None | False | None | False | 2769.15 | 0 | 3610656 | 131239 | None | PWD ELE SR V-6,IT.NO 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1848.59 | 1848.59 | 13.0 | False | None | None | False | None | False | 24031.67 | 0 | 3610657 | 131239 | None | PWD ELE SR V-6,IT.NO 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3316.8 | 3316.8 | 24.0 | False | None | None | False | None | False | 79603.2 | 0 | 3610658 | 131239 | None | PWD ELE SR V-6,IT.NO 13.11 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.
On wall / ceiling / Rafter / Girders
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 390.29 | 390.29 | 24.0 | False | None | None | False | None | False | 9366.96 | 0 | 3610659 | 131239 | None | PWD ELE SR V-6,IT.NO 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 151.16 | 151.16 | 83.0 | False | None | None | False | None | False | 12546.28 | 0 | 3610660 | 131239 | None | PWD ELE SR V-6,IT.NO 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 875.97 | 875.97 | 13.0 | False | None | None | False | None | False | 11387.61 | 0 | 3610661 | 131239 | None | PWD ELE SR V-6,IT.NO 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 200.72 | 200.72 | 3.0 | False | None | None | False | None | False | 602.16 | 0 | 3610662 | 131239 | None | PWD ELE SR V-6,IT.NO 5.42.1 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete
16SWG
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 86000.0 | False | None | None | False | None | False | 45580.0 | 0 | 3610663 | 131239 | None | PWD ELE SR V-6,IT.NO 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 4255.97 | 4255.97 | 5.0 | False | None | None | False | None | False | 21279.85 | 0 | 3610664 | 131239 | None | PWD ELE SR V-6,IT.NO 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
40x40x6mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 377.9 | 377.9 | 10.0 | False | None | None | False | None | False | 3779.0 | 0 | 3610665 | 131239 | None | PWD ELE SR V-6,IT.NO 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
50x100x50x6mm C channel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 936.68 | 936.68 | 10.0 | False | None | None | False | None | False | 9366.8 | 0 | 3610666 | 131239 | None | PWD ELE SR V-6,IT.NO 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs)
100Amps 25kA
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 10515.39 | 10515.39 | 1.0 | False | None | None | False | None | False | 10515.39 | 0 | 3610667 | 131239 | None | PWD ELE SR V-6,iT.NO 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
50-63Amps DP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3826.03 | 3826.03 | 10.0 | False | None | None | False | None | False | 38260.3 | 0 | 3610668 | 131239 | None | PWD ELE SR V-6,IT.NO 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 11541.29 | 11541.29 | 1.0 | False | None | None | False | None | False | 11541.29 | 0 | 3610669 | 131239 | None | PWD ELE SR V-6,IT.NO 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3610670 | 131239 | None | PWD ELE SR V-6,IT.NO 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 696.32 | 696.32 | 3.0 | False | None | None | False | None | False | 2088.96 | 0 | 3610671 | 131239 | None | PWD ELE SR V-6,IT.NO5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kvar | 594.72 | 594.72 | 15.0 | False | None | None | False | None | False | 8920.8 | 0 | 3610672 | 131239 | None | 5.19.9 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2885.63 | 2885.63 | 2.0 | False | None | None | False | None | False | 5771.26 | 0 | 3610673 | 131239 | None | 5.19.12 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6120.66 | 6120.66 | 1.0 | False | None | None | False | None | False | 6120.66 | 0 | 3610674 | 131239 | None | 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3826.03 | 3826.03 | 1.0 | False | None | None | False | None | False | 3826.03 | 0 | 3610675 | 131239 | None | 5.20.8 | Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6377.13 | 6377.13 | 3.0 | False | None | None | False | None | False | 19131.39 | 0 | 3610676 | 131239 | None | 32.05 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 109549.9 | 109549.9 | 0.1 | False | None | None | False | None | False | 10954.99 | 0 | 3610677 | 131239 | None | 32.09 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 190882.82 | 190882.82 | 0.05 | False | None | None | False | None | False | 9544.141 | 0 | 3610678 | 131239 | None | 32.13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 393892.97 | 393892.97 | 0.1 | False | None | None | False | None | False | 39389.297 | 0 | 3610679 | 131239 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 25877.75 | 25877.75 | 0.05 | False | None | None | False | None | False | 1293.8875 | 0 | 3610680 | 131239 | None | 31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 38581.22 | 38581.22 | 0.2 | False | None | None | False | None | False | 7716.244 | 0 | 3610681 | 131239 | None | 6.17.6 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 15.41 | 15.41 | 20.0 | False | None | None | False | None | False | 308.2 | 0 | 3610682 | 131239 | None | 16.17.10 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 148.68 | 148.68 | 16.0 | False | None | None | False | None | False | 2378.88 | 0 | 3610683 | 131239 | None | 11.11.5 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 333.29 | 333.29 | 9.0 | False | None | None | False | None | False | 2999.61 | 0 | 3610684 | 131239 | None | 11.6.3 | Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 5641.17 | 5641.17 | 8.0 | False | None | None | False | None | False | 45129.36 | 0 | 3610685 | 131239 | None | 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4985.74 | 4985.74 | 2.0 | False | None | None | False | None | False | 9971.48 | 0 | 3610686 | 131239 | None | 13.4.1 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1810.18 | 1810.18 | 3.0 | False | None | None | False | None | False | 5430.54 | 0 | 3610687 | 131239 | None | 5.14.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 2738.19 | 2738.19 | 2.0 | False | None | None | False | None | False | 5476.38 | 0 | 3610688 | 131239 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 169.74 | 169.74 | 24.0 | False | None | None | False | None | False | 4073.76 | 0 | 3610689 | 131239 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 395.24 | 395.24 | 31.0 | False | None | None | False | None | False | 12252.44 | 0 | 3610690 | 131239 | None | 2.2.5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 1225.37 | 1225.37 | 4.0 | False | None | None | False | None | False | 4901.48 | 0 | 3610691 | 131239 | None | 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 144.96 | 144.96 | 6.0 | False | None | None | False | None | False | 869.76 | 0 | 3610692 | 131239 | None | 12.46 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 78.06 | 78.06 | 21.0 | False | None | None | False | None | False | 1639.26 | 0 | 3610693 | 131239 | None | 3.6.11 | TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 193.28 | 193.28 | 2.0 | False | None | None | False | None | False | 386.56 | 0 | 3610694 | 131239 | None | 12.2.1 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 304.79 | 304.79 | 1.0 | False | None | None | False | None | False | 304.79 | 0 | 3610695 | 131239 | None | 32.02 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 98168.45 | 98168.45 | 0.1 | False | None | None | False | None | False | 9816.845 | 0 | 3610696 | 131239 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 25877.75 | 25877.75 | 0.1 | False | None | None | False | None | False | 2587.775 | 0 | 3610697 | 131239 | None | pwd sr | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 15.41 | 15.41 | 15.0 | False | None | None | False | None | False | 231.15 | 0 | 3610698 | 131239 | None | 11..11.7 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 527.81 | 527.81 | 3.0 | False | None | None | False | None | False | 1583.43 | 0 | 3610699 | 131239 | None | 12.27 | Supplying & Fixing of Special Type pigmy and candle lamp.
Operating voltage range from 180V to 265V, 50Hz AC power Supply"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 64.43 | 64.43 | 2.0 | False | None | None | False | None | False | 128.86 | 0 | 3610700 | 131239 | None | 11.8.1 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3004.58 | 3004.58 | 1.0 | False | None | None | False | None | False | 3004.58 | 0 | 3610701 | 131239 | None | 5.7.2 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 298.6 | 298.6 | 1.0 | False | None | None | False | None | False | 298.6 | 0 | 3610702 | 131239 | None | 5.30 | Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1709.82 | 1709.82 | 1.0 | False | None | None | False | None | False | 1709.82 | 0 | 3610703 | 131239 | None | 7.1.3 | Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 12689.84 | 12689.84 | 1.0 | False | None | None | False | None | False | 12689.84 | 0 | 3610704 | 131239 | None | PWD SR 2023-24 Volume 6 It No-9.3.3 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 84726.54 | 84726.54 | 1.0 | False | None | None | False | None | False | 84726.54 | 0 | 3610705 | 131239 | None | PWD SR 2023-24 Volume 6 It No-9.5.9 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 19693.91 | 19693.91 | 4.0 | False | None | None | False | None | False | 78775.64 | 0 | 3610706 | 131239 | None | A.R | Item Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 300000.0 | 300000.0 | 1.0 | False | None | None | False | None | False | 300000.0 | 0 | 3610707 | 131239 | None | LQR | IP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 23836.0 | 23836.0 | 4.0 | False | None | None | False | None | False | 95344.0 | 0 | 3610708 | 131239 | None | LQR | IP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 25606.0 | 25606.0 | 2.0 | False | None | None | False | None | False | 51212.0 | 0 | 3610709 | 131239 | None | LQR | Supplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3610710 | 131239 | None | LQR | Supply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 17110.0 | 17110.0 | 2.0 | False | None | None | False | None | False | 34220.0 | 0 | 3610711 | 131239 | None | LQR | Supply and Installation of I/Os
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 147.5 | 147.5 | 12.0 | False | None | None | False | None | False | 1770.0 | 0 | 3610712 | 131239 | None | LQR | Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 265.5 | 265.5 | 12.0 | False | None | None | False | None | False | 3186.0 | 0 | 3610713 | 131239 | None | LQR | Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 336.3 | 336.3 | 6.0 | False | None | None | False | None | False | 2017.8 | 0 | 3610714 | 131239 | None | LQR | Supply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3610715 | 131239 | None | V-6 8.1 | Supplying and drawing UTP-CAT 6E LAN cable
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 47.08 | 47.08 | 600.0 | False | None | None | False | None | False | 28248.0 | 0 | 3610716 | 131239 | None | 1.2.2 | Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 96.64 | 96.64 | 500.0 | False | None | None | False | None | False | 48320.0 | 0 | 3610717 | 131239 | None | 8.12.3 | Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3778.95 | 3778.95 | 1.0 | False | None | None | False | None | False | 3778.95 | 0 | 3610718 | 131239 | None | 8.4.1 v-6 | Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 6061.19 | 6061.19 | 1.0 | False | None | None | False | None | False | 6061.19 | 0 | 3610719 | 131239 | None | 1.01 | Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 8767.16 | 8767.16 | 8.0 | False | None | None | False | None | False | 70137.28 | 0 | 3610720 | 131239 | None | 2.02 | Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 1379.01 | 1379.01 | 8.0 | False | None | None | False | None | False | 11032.08 | 0 | 3610721 | 131239 | None | 6.05 | Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 107.79 | 107.79 | 6.0 | False | None | None | False | None | False | 646.74 | 0 | 3610722 | 131239 | None | 13.12 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 59.47 | 59.47 | 6.0 | False | None | None | False | None | False | 356.82 | 0 | 3610723 | 131239 | None | 2.16 | Supply of Spiral Earth Electrode
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 296.12 | 296.12 | 11.0 | False | None | None | False | None | False | 3257.32 | 0 | 3610724 | 131239 | None | 2.16 | Erection of Spiral Earth Electrode
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 115.23 | 115.23 | 11.0 | False | None | None | False | None | False | 1267.53 | 0 | 3610725 | 131239 | None | 68.17 | Supply and fixing of Caution/Danger Board
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 185.85 | 185.85 | 6.0 | False | None | None | False | None | False | 1115.1 | 0 | 3610726 | 131239 | None | 4.02 | Supply of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 110.27 | 110.27 | 8.0 | False | None | None | False | None | False | 882.16 | 0 | 3610727 | 131239 | None | 5.09 | Erection of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 52.04 | 52.04 | 8.0 | False | None | None | False | None | False | 416.32 | 0 | 3610728 | 131239 | None | 24.05 | Supply and fixing of 11 kV, 400 Amps Double Break GOS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 26341.14 | 26341.14 | 1.0 | False | None | None | False | None | False | 26341.14 | 0 | 3610729 | 131239 | None | 24.07 | Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 7521.97 | 7521.97 | 1.0 | False | None | None | False | None | False | 7521.97 | 0 | 3610730 | 131239 | None | 25.01 | Supply of DOLO Cut Out
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set of 3 Nos | 7279.13 | 7279.13 | 1.0 | False | None | None | False | None | False | 7279.13 | 0 | 3610731 | 131239 | None | 13.01 | Erection of DOLO Cut Out
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set of 3 Nos | 293.64 | 293.64 | 1.0 | False | None | None | False | None | False | 293.64 | 0 | 3610732 | 131239 | None | 13.07 | Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 210958.34 | 210958.34 | 1.0 | False | None | None | False | None | False | 210958.34 | 0 | 3610733 | 131239 | None | 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 4348.89 | 4348.89 | 8.0 | False | None | None | False | None | False | 34791.12 | 0 | 3610734 | 131239 | None | 12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | MT | 158.59 | 158.59 | 100.0 | False | None | None | False | None | False | 15859.0 | 0 | 3610735 | 131239 | None | 12.58.9 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 2035.68 | 2035.68 | 100.0 | False | None | None | False | None | False | 203568.0 | 0 | 3610736 | 131239 | None | 12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 9194.62 | 9194.62 | 10.0 | False | None | None | False | None | False | 91946.2 | 0 | 3610737 | 131239 | None | 45.07 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 5039.01 | 5039.01 | 4.0 | False | None | None | False | None | False | 20156.04 | 0 | 3610738 | 131239 | None | 45.04 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 3887.98 | 3887.98 | 2.0 | False | None | None | False | None | False | 7775.96 | 0 | 3610739 | 131239 | None | 36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 1102296.17 | 1102296.17 | 0.1 | False | None | None | False | None | False | 110229.617 | 0 | 3610740 | 131239 | None | 38. | Providing chain link fencing 50 mm size of 8 guage properly stretched between
rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be
welded to the Pole and block pipe at top and bottom as required including cost
of all materials, labour, lead and lifts, cutting, bending wherever necessary,
wastage and lapping etc., complete as per the direction of the engineer
incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1222.89 | 1222.89 | 150.0 | False | None | None | False | None | False | 183433.5 | 0 | 3610741 | 131239 | None | 5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 176000.0 | False | None | None | False | None | False | 93280.0 | 0 | 3610742 | 131239 | None | 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 4255.97 | 4255.97 | 6.0 | False | None | None | False | None | False | 25535.82 | 0 | 3610743 | 131239 | None | 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 377.9 | 377.9 | 12.0 | False | None | None | False | None | False | 4534.8 | 0 | 3610744 | 131239 | None | 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 936.68 | 936.68 | 12.0 | False | None | None | False | None | False | 11240.16 | 0 | 3610745 | 131239 | None | 5.15.15 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 29172.26 | 29172.26 | 1.0 | False | None | None | False | None | False | 29172.26 | 0 | 3610746 | 131239 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3610747 | 131239 | None | 10.1.3 | Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have +
1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating
lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting
battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr
at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 558914.14 | 558914.14 | 1.0 | False | None | None | False | None | False | 558914.14 | 0 | 3610748 | 131239 | None | 10.2.2 | Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the
accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 72742.93 | 72742.93 | 1.0 | False | None | None | False | None | False | 72742.93 | 0 | 3610749 | 131239 | None | A.R | Supply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 3540.0 | 3540.0 | 5.0 | False | None | None | False | None | False | 17700.0 | 0 | 3610750 | 131239 | None | A.R | Supply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 236.0 | 236.0 | 50.0 | False | None | None | False | None | False | 11800.0 | 0 | 3610751 | 131239 | None | 58.02 | LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 98973.8 | 98973.8 | 1.0 | False | None | None | False | None | False | 98973.8 | 0 | 3610752 | 131239 | None | 53.01 | CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 24302.99 | 24302.99 | 1.0 | False | None | None | False | None | False | 24302.99 | 0 | 3610753 | 131239 | None | 10.01 | Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 173.46 | 173.46 | 15.0 | False | None | None | False | None | False | 2601.9 | 0 | 3610754 | 131239 | None | v-6 2.02 | Supply of 11 kV, Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr
Long, 145 Kg WL"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 603.39 | 603.39 | 6.0 | False | None | None | False | None | False | 3620.34 | 0 | 3610755 | 131239 | None | v-6 2.02 | Erection of 11 kV, Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr
Long, 145 Kg WL"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 318.42 | 318.42 | 6.0 | False | None | None | False | None | False | 1910.52 | 0 | 3610756 | 131239 | None | v-6 6.06 | Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP
Rod) "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 254.0 | 254.0 | 18.0 | False | None | None | False | None | False | 4572.0 | 0 | 3610757 | 131239 | None | v-6 6.10 | Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 235.45 | 235.45 | 18.0 | False | None | None | False | None | False | 4238.1 | 0 | 3610758 | 131239 | None | 13.12 v-6 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 59.47 | 59.47 | 18.0 | False | None | None | False | None | False | 1070.46 | 0 | 3610759 | 131239 | None | v-6 6.08 | Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 73.1 | 73.1 | 4.0 | False | None | None | False | None | False | 292.4 | 0 | 3610760 | 131239 | None | 7.02 | Supply of Rabbit ACSR Conductor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 57283.93 | 57283.93 | 1.0 | False | None | None | False | None | False | 57283.93 | 0 | 3610761 | 131239 | None | 6.02 V-6 | Erection of Rabbit ACSR Conductor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 5403.28 | 5403.28 | 1.0 | False | None | None | False | None | False | 5403.28 | 0 |
| 1721828234000 | 0 | None | None | Buildings | MUDNOOR IN SHORAPUR TALUK OF YADGIR DISTRICT (CIVIL WORKS) | 27736381.66 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3610762 | 131240 | None | CSR:V-3 PAGE NO 9 Itm 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | 100 Sqm | 486.93 | 486.93 | 17.09 | False | None | None | False | None | False | 8321.6337 | 0 | 3610763 | 131240 | None | V-1 page 8 itm 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 117.71 | 117.71 | 540.95 | False | None | None | False | None | False | 63675.2245 | 0 | 3610764 | 131240 | None | V-1page 8 itm 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 126.38 | 126.38 | 1430.43 | False | None | None | False | None | False | 180777.7434 | 0 | 3610765 | 131240 | None | V-1page 8 itm 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 449.76 | 449.76 | 254.05 | False | None | None | False | None | False | 114261.528 | 0 | 3610766 | 131240 | None | V-3page 3 A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 167.27 | 167.27 | 218.94 | False | None | None | False | None | False | 36622.0938 | 0 | 3610767 | 131240 | None | V-2page5 itm 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 146.2 | 146.2 | 774.16 | False | None | None | False | None | False | 113182.192 | 0 | 3610768 | 131240 | None | V-1pg7 itm1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 329.57 | 329.57 | 901.41 | False | None | None | False | None | False | 297077.6937 | 0 | 3610769 | 131240 | None | V-1page7vitm1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 587.29 | 587.29 | 747.04 | False | None | None | False | None | False | 438729.1216 | 0 | 3610770 | 131240 | None | V-1page 15 itm2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7420.37 | 7420.37 | 155.33 | False | None | None | False | None | False | 1152606.0721 | 0 | 3610771 | 131240 | None | V-1page15 itm 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8478.33 | 8478.33 | 177.95 | False | None | None | False | None | False | 1508718.8235 | 0 | 3610772 | 131240 | None | V-1page16 itm 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8635.33 | 8635.33 | 13.4 | False | None | None | False | None | False | 115713.422 | 0 | 3610773 | 131240 | None | V-1page15itm 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 14413.41 | 14413.41 | 57.58 | False | None | None | False | None | False | 829924.1478 | 0 | 3610774 | 131240 | None | V-3page135itm15.4 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 252.76 | 252.76 | 13.0 | False | None | None | False | None | False | 3285.88 | 0 | 3610775 | 131240 | None | V-2page55 itm 8.16.a | Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1533.88 | 1533.88 | 13.81 | False | None | None | False | None | False | 21182.8828 | 0 | 3610776 | 131240 | None | V-1page18itm2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Tonne | 110837.22 | 110837.22 | 50.59 | False | None | None | False | None | False | 5607254.9598 | 0 | 3610777 | 131240 | None | 18-19SR ITM4.21 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 38.94 | 38.94 | 145.02 | False | None | None | False | None | False | 5647.0788 | 0 | 3610778 | 131240 | None | DATA RATE | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 86.14 | 86.14 | 145.02 | False | None | None | False | None | False | 12492.0228 | 0 | 3610779 | 131240 | None | V-2PAGE 9 ITM5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7915.97 | 7915.97 | 8.76 | False | None | None | False | None | False | 69343.8972 | 0 | 3610780 | 131240 | None | V-2PAGE 14 ITM 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1623.09 | 1623.09 | 1253.93 | False | None | None | False | None | False | 2035241.2437 | 0 | 3610781 | 131240 | None | V-2page 14 itm 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks
of size 400x100x200mm having block density more than 1800kg/m3
and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005
including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1367.86 | 1367.86 | 171.24 | False | None | None | False | None | False | 234232.3464 | 0 | 3610782 | 131240 | None | V-2 page100 itm 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 122431.79 | 122431.79 | 1.2 | False | None | None | False | None | False | 146918.148 | 0 | 3610783 | 131240 | None | V-2 page 105 itm 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 1258.82 | 1258.82 | 32.0 | False | None | None | False | None | False | 40282.24 | 0 | 3610784 | 131240 | None | 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 681.45 | 681.45 | 64.0 | False | None | None | False | None | False | 43612.8 | 0 | 3610785 | 131240 | None | 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 464.63 | 464.63 | 32.0 | False | None | None | False | None | False | 14868.16 | 0 | 3610786 | 131240 | None | 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 185.85 | 185.85 | 64.0 | False | None | None | False | None | False | 11894.4 | 0 | 3610787 | 131240 | None | 22.15.9 | PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 86.73 | 86.73 | 128.0 | False | None | None | False | None | False | 11101.44 | 0 | 3610788 | 131240 | None | 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 123.9 | 123.9 | 32.0 | False | None | None | False | None | False | 3964.8 | 0 | 3610789 | 131240 | None | 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 1303.43 | 1303.43 | 32.0 | False | None | None | False | None | False | 41709.76 | 0 | 3610790 | 131240 | None | V-2page69 itm 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 74.34 | 74.34 | 192.0 | False | None | None | False | None | False | 14273.28 | 0 | 3610791 | 131240 | None | 20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 64.43 | 64.43 | 168.45 | False | None | None | False | None | False | 10853.2335 | 0 | 3610792 | 131240 | None | V-2page105 itm 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4115.96 | 4115.96 | 74.84 | False | None | None | False | None | False | 308038.4464 | 0 | 3610793 | 131240 | None | V-2page109 itm 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 8343.43 | 8343.43 | 69.39 | False | None | None | False | None | False | 578950.6077 | 0 | 3610794 | 131240 | None | V-2page109 itm 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 7085.84 | 7085.84 | 6.84 | False | None | None | False | None | False | 48467.1456 | 0 | 3610795 | 131240 | None | V-2page 86itm11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 208.15 | 208.15 | 1600.83 | False | None | None | False | None | False | 333212.7645 | 0 | 3610796 | 131240 | None | V-2page 111itm 12.93.1 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/
cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | m | 869.78 | 869.78 | 64.35 | False | None | None | False | None | False | 55970.343 | 0 | 3610797 | 131240 | None | V-2page84 itm 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kgs | 168.5 | 168.5 | 1724.91 | False | None | None | False | None | False | 290647.335 | 0 | 3610798 | 131240 | None | V-2page 41itm 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 386.57 | 386.57 | 1763.82 | False | None | None | False | None | False | 681839.8974 | 0 | 3610799 | 131240 | None | V-2page 43 itm 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 261.43 | 261.43 | 1176.83 | False | None | None | False | None | False | 307658.6669 | 0 | 3610800 | 131240 | None | V-2page50 itm 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 123.9 | 123.9 | 2919.03 | False | None | None | False | None | False | 361667.817 | 0 | 3610801 | 131240 | None | V-2page42itm 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 432.41 | 432.41 | 975.48 | False | None | None | False | None | False | 421807.3068 | 0 | 3610802 | 131240 | None | V-2page41 itm 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 438.61 | 438.61 | 163.05 | False | None | None | False | None | False | 71515.3605 | 0 | 3610803 | 131240 | None | 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 47.08 | 47.08 | 2013.85 | False | None | None | False | None | False | 94812.058 | 0 | 3610804 | 131240 | None | 10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 254.88 | 254.88 | 13.0 | False | None | None | False | None | False | 3313.44 | 0 | 3610805 | 131240 | None | V-2page 54itm 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 64.43 | 64.43 | 628.05 | False | None | None | False | None | False | 40465.2615 | 0 | 3610806 | 131240 | None | V-2page61itm 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1455.83 | 1455.83 | 580.89 | False | None | None | False | None | False | 845677.0887 | 0 | 3610807 | 131240 | None | V-2page59 itm9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 991.2 | 991.2 | 71.5 | False | None | None | False | None | False | 70870.8 | 0 | 3610808 | 131240 | None | V-2page63 itm 9.32 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3199.1 | 3199.1 | 34.54 | False | None | None | False | None | False | 110496.914 | 0 | 3610809 | 131240 | None | V-2page 4 itm 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 365.51 | 365.51 | 316.07 | False | None | None | False | None | False | 115526.7457 | 0 | 3610810 | 131240 | None | V-2page 60 itm 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1101.47 | 1101.47 | 59.14 | False | None | None | False | None | False | 65140.9358 | 0 | 3610811 | 131240 | None | V-2page65 itmv9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1795.31 | 1795.31 | 259.57 | False | None | None | False | None | False | 466008.6167 | 0 | 3610812 | 131240 | None | V-2 page85 itm11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 700.04 | 700.04 | 357.82 | False | None | None | False | None | False | 250488.3128 | 0 | 3610813 | 131240 | None | V-2 page 48itm 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 157.35 | 157.35 | 2741.14 | False | None | None | False | None | False | 431318.379 | 0 | 3610814 | 131240 | None | V-2page 46itm8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 193.28 | 193.28 | 759.66 | False | None | None | False | None | False | 146827.0848 | 0 | 3610815 | 131240 | None | V-2page47 itm8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 61.95 | 61.95 | 96.21 | False | None | None | False | None | False | 5960.2095 | 0 | 3610816 | 131240 | None | V-2page48 itm 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 142.49 | 142.49 | 76.23 | False | None | None | False | None | False | 10862.0127 | 0 | 3610817 | 131240 | None | V-2page47itm 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 65.67 | 65.67 | 179.6 | False | None | None | False | None | False | 11794.332 | 0 | 3610818 | 131240 | None | 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 838.8 | 838.8 | 179.6 | False | None | None | False | None | False | 150648.48 | 0 | 3610819 | 131240 | None | V-2page64itm 9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 2044.35 | 2044.35 | 17.32 | False | None | None | False | None | False | 35408.142 | 0 | 3610820 | 131240 | None | V-2page77 itm 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 5548.24 | 5548.24 | 5.25 | False | None | None | False | None | False | 29128.26 | 0 | 3610821 | 131240 | None | 15.12 | Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1443.44 | 1443.44 | 726.5 | False | None | None | False | None | False | 1048659.16 | 0 | 3610822 | 131240 | None | V-2PAGE22 ITM 7.17 | Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 411.35 | 411.35 | 24.74 | False | None | None | False | None | False | 10176.799 | 0 | 3610823 | 131240 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 94.35 | False | None | None | False | None | False | 1199916.882 | 0 | 3610824 | 131240 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 13565.56 | 13565.56 | 51.01 | False | None | None | False | None | False | 691979.2156 | 0 | 3610825 | 131240 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 115.4 | False | None | None | False | None | False | 1467624.888 | 0 | 3610826 | 131240 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 7.07 | False | None | None | False | None | False | 89914.2804 | 0 | 3610827 | 131240 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 13565.56 | 13565.56 | 12.12 | False | None | None | False | None | False | 164414.5872 | 0 | 3610828 | 131240 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 11911.13 | 11911.13 | 14.18 | False | None | None | False | None | False | 168899.8234 | 0 | 3610829 | 131240 | None | 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4317.92 | 4317.92 | 20.48 | False | None | None | False | None | False | 88431.0016 | 0 | 3610830 | 131240 | None | 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 141.25 | 141.25 | 36.0 | False | None | None | False | None | False | 5085.0 | 0 | 3610831 | 131240 | None | 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1642.91 | 1642.91 | 56.5 | False | None | None | False | None | False | 92824.415 | 0 | 3610832 | 131240 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 6601.39 | 6601.39 | 30.54 | False | None | None | False | None | False | 201606.4506 | 0 | 3610833 | 131240 | None | 10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4877.94 | 4877.94 | 9.69 | False | None | None | False | None | False | 47267.2386 | 0 | 3610834 | 131240 | None | 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 761.99 | 761.99 | 92.01 | False | None | None | False | None | False | 70110.6999 | 0 | 3610835 | 131240 | None | 8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 350.64 | 350.64 | 215.82 | False | None | None | False | None | False | 75675.1248 | 0 | 3610836 | 131240 | None | 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 360.55 | 360.55 | 68.92 | False | None | None | False | None | False | 24849.106 | 0 | 3610837 | 131240 | None | 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3533.63 | 3533.63 | 11.09 | False | None | None | False | None | False | 39187.9567 | 0 | 3610838 | 131240 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 6601.39 | 6601.39 | 13.73 | False | None | None | False | None | False | 90637.0847 | 0 | 3610839 | 131240 | None | 10.1.1 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4963.43 | 4963.43 | 3.81 | False | None | None | False | None | False | 18910.6683 | 0 | 3610840 | 131240 | None | 1.4.1 V-1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 299.84 | 299.84 | 11.06 | False | None | None | False | None | False | 3316.2304 | 0 | 3610841 | 131240 | None | 1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 320.9 | 320.9 | 1.7 | False | None | None | False | None | False | 545.53 | 0 | 3610842 | 131240 | None | 17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1391.4 | 1391.4 | 7.0 | False | None | None | False | None | False | 9739.8 | 0 | 3610843 | 131240 | None | 17.1 V-2 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1241.48 | 1241.48 | 0.28 | False | None | None | False | None | False | 347.6144 | 0 | 3610844 | 131240 | None | 17.2 V-2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1469.45 | 1469.45 | 0.14 | False | None | None | False | None | False | 205.723 | 0 | 3610845 | 131240 | None | 17. V-2 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1476.89 | 1476.89 | 0.14 | False | None | None | False | None | False | 206.7646 | 0 | 3610846 | 131240 | None | 17.4 V-2 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1659.02 | 1659.02 | 0.14 | False | None | None | False | None | False | 232.2628 | 0 | 3610847 | 131240 | None | 17.14 V-2 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1449.63 | 1449.63 | 1.0 | False | None | None | False | None | False | 1449.63 | 0 | 3610848 | 131240 | None | V3 305.3.4 | Compacting Original Ground
Compacting original ground supporting embankment
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 130.1 | 130.1 | 60.0 | False | None | None | False | None | False | 7806.0 | 0 | 3610849 | 131240 | None | V-3 4.2 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 2922.8 | 2922.8 | 30.0 | False | None | None | False | None | False | 87684.0 | 0 | 3610850 | 131240 | None | V3 6.1 ISSUE RATE | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 6095.88 | 6095.88 | 20.0 | False | None | None | False | None | False | 121917.6 | 0 | 3610851 | 131240 | None | V-3 6.2 ISSUE RATE | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 11107.64 | 11107.64 | 40.0 | False | None | None | False | None | False | 444305.6 | 0 | 3610852 | 131240 | None | V-3 8.10 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 105.32 | 105.32 | 15.0 | False | None | None | False | None | False | 1579.8 | 0 | 3610853 | 131240 | None | V-3 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 87.97 | 87.97 | 448.0 | False | None | None | False | None | False | 39410.56 | 0 | 3610854 | 131240 | None | V-314621A | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)
300 x 250 x 100 mm Kerb Stone
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 296.12 | 296.12 | 100.0 | False | None | None | False | None | False | 29612.0 | 0 | 3610855 | 131240 | None | 2.1.4 V-1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7702.86 | 7702.86 | 1.2 | False | None | None | False | None | False | 9243.432 | 0 | 3610856 | 131240 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 9156.76 | 9156.76 | 6.48 | False | None | None | False | None | False | 59335.8048 | 0 | 3610857 | 131240 | None | 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 459.67 | 459.67 | 192.0 | False | None | None | False | None | False | 88256.64 | 0 | 3610858 | 131240 | None | 8.31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 220.54 | 220.54 | 192.0 | False | None | None | False | None | False | 42343.68 | 0 | 3610859 | 131240 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8761.09 | 8761.09 | 9.36 | False | None | None | False | None | False | 82003.8024 | 0 | 3610860 | 131240 | None | 8.20 V-3 | Providing and fixing 1.8 m high GI barbed wire fencing with
2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete,
0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 672.78 | 672.78 | 390.0 | False | None | None | False | None | False | 262384.2 | 0 | 3610861 | 131240 | None | V1 1.15.2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 526.58 | 526.58 | 22.51 | False | None | None | False | None | False | 11853.3158 | 0 | 3610862 | 131240 | None | 2.5.2 V1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8732.83 | 8732.83 | 4.32 | False | None | None | False | None | False | 37725.8256 | 0 | 3610863 | 131240 | None | 2.5.2 V1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 9326.32 | 9326.32 | 5.89 | False | None | None | False | None | False | 54932.0248 | 0 | 3610864 | 131240 | None | V2 15.14 | UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 2072.85 | 2072.85 | 36.6 | False | None | None | False | None | False | 75866.31 | 0 | 3610865 | 131240 | None | V5 18.3 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2430.92 | 2430.92 | 8.0 | False | None | None | False | None | False | 19447.36 | 0 | 3610866 | 131240 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 14413.41 | 14413.41 | 9.87 | False | None | None | False | None | False | 142260.3567 | 0 | 3610867 | 131240 | None | 15.5 V-2 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 749.6 | 749.6 | 63.57 | False | None | None | False | None | False | 47652.072 | 0 | 3610868 | 131240 | None | 8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 110.27 | 110.27 | 20.1 | False | None | None | False | None | False | 2216.427 | 0 | 3610869 | 131240 | None | V-5P140I12.4 | Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3610870 | 131240 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3610871 | 131240 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above 50 Mtrs and upto 100 Mtr
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3610872 | 131240 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above100 Mtrs. and upto 150 Mtr
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3610873 | 131240 | None | V-5P143I12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 2394.99 | 2394.99 | 20.0 | False | None | None | False | None | False | 47899.8 | 0 | 3610874 | 131240 | None | V-5P155I13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 681.45 | 681.45 | 150.0 | False | None | None | False | None | False | 102217.5 | 0 | 3610875 | 131240 | None | V-5P143I12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3610876 | 131240 | None | V-5P154I12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3610877 | 131240 | None | 18-19 SR13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3610878 | 131240 | None | V-5P154I13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.
5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 39817.74 | 39817.74 | 1.0 | False | None | None | False | None | False | 39817.74 | 0 | 3610879 | 131240 | None | V-5P155I13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3610880 | 131240 | None | V-5P155I13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3610881 | 131240 | None | V-5P155I13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3610882 | 131240 | None | V-5P156I13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3610883 | 131240 | None | V-5P156I13.33 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 1672.65 | 1672.65 | 1.0 | False | None | None | False | None | False | 1672.65 | 0 | 3610884 | 131240 | None | 2.6.2 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 208.15 | 208.15 | 165.0 | False | None | None | False | None | False | 34344.75 | 0 | 3610885 | 131240 | None | V-5P20I5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete
16 SWG
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3610886 | 131240 | None | V-5P21I5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.
600mmx600mmx170mm.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3610887 | 131240 | None | 5.6.6 V-6 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 404.08 | 404.08 | 1.0 | False | None | None | False | None | False | 404.08 | 0 | 3610888 | 131240 | None | 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 514.19 | 514.19 | 1.0 | False | None | None | False | None | False | 514.19 | 0 | 3610889 | 131240 | None | 13.18.1 | Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 344.44 | 344.44 | 1.0 | False | None | None | False | None | False | 344.44 | 0 | 3610890 | 131240 | None | 5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kvar | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 | 3610891 | 131240 | None | 1.23 | Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per
specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 3323.0 | 3323.0 | 164.36 | False | None | None | False | None | False | 546168.28 | 0 |
| 1721828234000 | 0 | None | None | Buildings | MUDNOOR IN SHORAPUR TALUK OF YADGIR DISTRICT (WATER SUPPLY AND SANITARY WORKS) | 2711710.47 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3610892 | 131241 | None | V-2 13.50.5 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work
40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 376.66 | 376.66 | 50.0 | False | None | None | False | None | False | 18833.0 | 0 | 3610893 | 131241 | None | V-2 13.50.6 | Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 478.25 | 478.25 | 20.0 | False | None | None | False | None | False | 9565.0 | 0 | 3610894 | 131241 | None | V-2 13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 358.07 | 358.07 | 185.0 | False | None | None | False | None | False | 66242.95 | 0 | 3610895 | 131241 | None | V-2 13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 477.02 | 477.02 | 120.0 | False | None | None | False | None | False | 57242.4 | 0 | 3610896 | 131241 | None | V-2 IT.NO 13.47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 244.08 | 244.08 | 35.0 | False | None | None | False | None | False | 8542.8 | 0 | 3610897 | 131241 | None | V-2 IT.NO 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 360.55 | 360.55 | 50.0 | False | None | None | False | None | False | 18027.5 | 0 | 3610898 | 131241 | None | V-2 P.NO 128 IT.NO 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 302.32 | 302.32 | 55.0 | False | None | None | False | None | False | 16627.6 | 0 | 3610899 | 131241 | None | V-2 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed
to wooden cleats with C.P. brass screws and washers complete."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1511.58 | 1511.58 | 21.0 | False | None | None | False | None | False | 31743.18 | 0 | 3610900 | 131241 | None | V-2 P.NO 127 IT.NO 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6891.32 | 6891.32 | 4.0 | False | None | None | False | None | False | 27565.28 | 0 | 3610901 | 131241 | None | V-2 P.NO 130 IT.NO 14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 614.54 | 614.54 | 4.0 | False | None | None | False | None | False | 2458.16 | 0 | 3610902 | 131241 | None | V-2 P.NO 123 IT.NO 14.38 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of
the same materials with snap fittings of approved quality and colour,
weighing not less than 105 g"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 179.66 | 179.66 | 4.0 | False | None | None | False | None | False | 718.64 | 0 | 3610903 | 131241 | None | V-2 P.NO 178 IT.NO 14.3.1 | Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush
bend, overflow arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete, including
painting of fittings and brackets, cutting and making good the walls and
floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 7405.5 | 7405.5 | 9.0 | False | None | None | False | None | False | 66649.5 | 0 | 3610904 | 131241 | None | V-2 P.NO 124 IT.NO14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6051.28 | 6051.28 | 10.0 | False | None | None | False | None | False | 60512.8 | 0 | 3610905 | 131241 | None | V-2 P.NO 126 IT.NO 14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6296.6 | 6296.6 | 2.0 | False | None | None | False | None | False | 12593.2 | 0 | 3610906 | 131241 | None | V-2 P.NO 126 IT.NO 14.10.1.1 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per
IS:13983 with C.I. brackets and stainless steel plug 40 mm, including
painting of fittings and brackets, cutting and making good the walls
wherever required : (510x1040 mm bowl depth 250 mm)"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6960.7 | 6960.7 | 4.0 | False | None | None | False | None | False | 27842.8 | 0 | 3610907 | 131241 | None | V-2 13.15 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 898.28 | 898.28 | 12.0 | False | None | None | False | None | False | 10779.36 | 0 | 3610908 | 131241 | None | V-2 P.NO 124 IT.NO 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3818.6 | 3818.6 | 13.0 | False | None | None | False | None | False | 49641.8 | 0 | 3610909 | 131241 | None | V-2 P.NO 120 IT.NO 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 382.85 | 382.85 | 90.0 | False | None | None | False | None | False | 34456.5 | 0 | 3610910 | 131241 | None | V-2 P.NO 120 IT.NO 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 469.58 | 469.58 | 70.0 | False | None | None | False | None | False | 32870.6 | 0 | 3610911 | 131241 | None | V-2 p.NO 120 IT.NO 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
25 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 70.0 | False | None | None | False | None | False | 41370.0 | 0 | 3610912 | 131241 | None | V-2 P.NO 120 IT.NO 13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
32 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 690.12 | 690.12 | 30.0 | False | None | None | False | None | False | 20703.6 | 0 | 3610913 | 131241 | None | V-2 P.NO 120 IT.NO 13.31.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
40 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 664.1 | 664.1 | 20.0 | False | None | None | False | None | False | 13282.0 | 0 | 3610914 | 131241 | None | V-2 P.NO 120IT.NO 13.31.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
50 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 967.66 | 967.66 | 20.0 | False | None | None | False | None | False | 19353.2 | 0 | 3610915 | 131241 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
20mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 268.86 | 268.86 | 50.0 | False | None | None | False | None | False | 13443.0 | 0 | 3610916 | 131241 | None | V-2 P.NO 120 IT.NO 13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
25mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 366.74 | 366.74 | 50.0 | False | None | None | False | None | False | 18337.0 | 0 | 3610917 | 131241 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
40mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 215.0 | False | None | None | False | None | False | 127065.0 | 0 | 3610918 | 131241 | None | V-2 P.NO 120 IT.NO 13.33.7 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
65mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 1734.6 | 1734.6 | 25.0 | False | None | None | False | None | False | 43365.0 | 0 | 3610919 | 131241 | None | V-2 P.NO 120 IT.NO 13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
50mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 893.32 | 893.32 | 40.0 | False | None | None | False | None | False | 35732.8 | 0 | 3610920 | 131241 | None | V2 13.5.2 | Providing and fixing ball valve (brass) of approved quality, High or low
pressure, with plastic floats complete :"
25 mm nominal bore
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 411.35 | 411.35 | 12.0 | False | None | None | False | None | False | 4936.2 | 0 | 3610921 | 131241 | None | V2-13.4 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 32 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 740.92 | 740.92 | 7.0 | False | None | None | False | None | False | 5186.44 | 0 | 3610922 | 131241 | None | V-2 13.4.3 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 40 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 869.78 | 869.78 | 9.0 | False | None | None | False | None | False | 7828.02 | 0 | 3610923 | 131241 | None | v2-13.4.4 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 50 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1059.35 | 1059.35 | 2.0 | False | None | None | False | None | False | 2118.7 | 0 | 3610924 | 131241 | None | V-2,A-13, IT.NO 13.2.1 | Brass bib-cock 15 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 354.35 | 354.35 | 19.0 | False | None | None | False | None | False | 6732.65 | 0 | 3610925 | 131241 | None | V-2 IT.NO 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Ltr | 11.15 | 11.15 | 3000.0 | False | None | None | False | None | False | 33450.0 | 0 | 3610926 | 131241 | None | V2 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 182.13 | 182.13 | 125.0 | False | None | None | False | None | False | 22766.25 | 0 | 3610927 | 131241 | None | Market Rate | Providing and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 177.0 | 177.0 | 55.0 | False | None | None | False | None | False | 9735.0 | 0 | 3610928 | 131241 | None | Market Rate | Air Vent Cowel
75mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 413.0 | 413.0 | 12.0 | False | None | None | False | None | False | 4956.0 | 0 | 3610929 | 131241 | None | Market Rate | Air Vent Cowel
110mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 590.0 | 590.0 | 12.0 | False | None | None | False | None | False | 7080.0 | 0 | 3610930 | 131241 | None | Market Rate | Supplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6844.0 | 6844.0 | 9.0 | False | None | None | False | None | False | 61596.0 | 0 | 3610931 | 131241 | None | Market Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2183.0 | 2183.0 | 9.0 | False | None | None | False | None | False | 19647.0 | 0 | 3610932 | 131241 | None | Market Rate | Supplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 767.0 | 767.0 | 95.0 | False | None | None | False | None | False | 72865.0 | 0 | 3610933 | 131241 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
a) 65mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4130.0 | 4130.0 | 2.0 | False | None | None | False | None | False | 8260.0 | 0 | 3610934 | 131241 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
b) 50mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3304.0 | 3304.0 | 4.0 | False | None | None | False | None | False | 13216.0 | 0 | 3610935 | 131241 | None | V2 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Unit | 345.68 | 345.68 | 4.0 | False | None | None | False | None | False | 1382.72 | 0 | 3610936 | 131241 | None | V2 9.29 | Providing and laying flooring and steps fine dressed granite stone slabs
40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with
cement mortar 1:3 over existing cement concrete bed , including cost
of materials, mortar, labour, curing complete as per specifications."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 5335.13 | 5335.13 | 18.0 | False | None | None | False | None | False | 96032.34 | 0 | 3610937 | 131241 | None | V2 10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded
and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti
tions by cutting a chase of appropriate width with chase cutter and embed
ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3455.57 | 3455.57 | 10.0 | False | None | None | False | None | False | 34555.7 | 0 | 3610938 | 131241 | None | V2 13.28 | Providing and fixing PTMT extension nipple for water tank pipe, fittings
of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 79.3 | 79.3 | 70.0 | False | None | None | False | None | False | 5551.0 | 0 | 3610939 | 131241 | None | 14.36.1 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of
approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g
"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 111.51 | 111.51 | 23.0 | False | None | None | False | None | False | 2564.73 | 0 | 3610940 | 131241 | None | 14.37.1 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective
length of tail pipe 260 mm from the centre of the waste coupling, 77 mm
breadth with 25 mm minimum water seal, weighing not less than 260 g"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Unit | 379.13 | 379.13 | 23.0 | False | None | None | False | None | False | 8719.99 | 0 | 3610941 | 131241 | None | 13.8.1.1 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 102.84 | 102.84 | 23.0 | False | None | None | False | None | False | 2365.32 | 0 | 3610942 | 131241 | None | 14.22.A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1003.59 | 1003.59 | 23.0 | False | None | None | False | None | False | 23082.57 | 0 | 3610943 | 131241 | None | 13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 768.18 | 768.18 | 53.0 | False | None | None | False | None | False | 40713.54 | 0 | 3610944 | 131241 | None | V2 14.63A | Providing and fixing Single lever sink mixer with swivel spout top
outlet wall mountable made of Stainless steel with all concealed fitting
arrangements & all necessary accesories complete - Class Economy "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4667.31 | 4667.31 | 4.0 | False | None | None | False | None | False | 18669.24 | 0 | 3610945 | 131241 | None | 14.4.1 | Providing and fixing white vitreous china flat back or wall corner type
lipped front urinal basin of 430x260x350 mm and 340x410x265 mm
sizes respectively with automatic flushing cistern with standard flush
pipe and C.P. brass spreaders with brass unions and G.I clamps complete,
including painting of fittings and brackets, cutting and making good the
walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 5518.51 | 5518.51 | 4.0 | False | None | None | False | None | False | 22074.04 | 0 | 3610946 | 131241 | None | ELE 7.3 | Supplying, installation, testing and commissioning of solar hot water
heater comprising of solar Flat Plate Collector (FPC) of size
2120x1040x100mm and stainless steel hot water storage tank with
stainless steel heat exchanger absorber made of copper sheet and
copper tube of following capacity aluminium box collector with
appropriate capacity electrical back up arrangement excluding inlet
and out let pipes. SS Model with 100mm thick of 48Kg/M3 density
Rock wool insulation with 22SWG Aluminium cladding."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 39372.94 | 39372.94 | 3.0 | False | None | None | False | None | False | 118118.82 | 0 | 3610947 | 131241 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-110mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 944.0 | 944.0 | 10.0 | False | None | None | False | None | False | 9440.0 | 0 | 3610948 | 131241 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-75mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 767.0 | 767.0 | 2.0 | False | None | None | False | None | False | 1534.0 | 0 | 3610949 | 131241 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-160MM dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1298.0 | 1298.0 | 1.0 | False | None | None | False | None | False | 1298.0 | 0 | 3610950 | 131241 | None | V-1,P.NO 6,IT.NO 1.4.1 | Earth work excavation by manual means for drains,canals, waste weir,
draft, approach channels, key trenches, foundation of bridges and
such simillar works in all kinds of soils , as per drawing and technical
specifications, including setting out, shoring, strutting, barricading,
caution lights, removal of stumps and other deleterious matter,
excavated surface leveled and sides neatly dressed disposing off the
excavated stuff or sorting & stacking the selected stuff for reuse in a
radius of 50 m and lift upto 1.5 m including cost of labour, tools & other
appurtenaces required to complete the work."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 299.84 | 299.84 | 224.0 | False | None | None | False | None | False | 67164.16 | 0 | 3610951 | 131241 | None | V-1 P.NO 7 IT.NO 1.11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 536.49 | 536.49 | 224.0 | False | None | None | False | None | False | 120173.76 | 0 | 3610952 | 131241 | None | V-5 P.NO 134 IT.NO 10.3 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013
with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of
elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing
the pipes alround to a depth of not less than 15 cms. with soft gravel
or selected earth available from the excavation etc. complete and giving
necessary hydraulic test to the required pressure as per ISS (contractor
will make his own arrangements for procuring water for testing) etc.
complete. for:"
Pipes of SN8 Self Fit - 160mm dia.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 764.46 | 764.46 | 300.0 | False | None | None | False | None | False | 229338.0 | 0 | 3610953 | 131241 | None | V-5 P.NO 134 IT.NO 10.2.4 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ).
- do - 160 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 713.66 | 713.66 | 70.0 | False | None | None | False | None | False | 49956.2 | 0 | 3610954 | 131241 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6757.51 | 6757.51 | 45.0 | False | None | None | False | None | False | 304087.95 | 0 | 3610955 | 131241 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6757.51 | 6757.51 | 15.0 | False | None | None | False | None | False | 101362.65 | 0 | 3610956 | 131241 | None | 13.39 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete
with C.I. grating brick masonry chamber 150 x 100 mm size P type With
Non Modular common burnt clay bricks of designation 3.5 & with water
tight C.I. cover with frame of 300 x300 mm size (inside) the weight of
cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as
per standard design:"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3197.86 | 3197.86 | 25.0 | False | None | None | False | None | False | 79946.5 | 0 | 3610957 | 131241 | None | 16.18 | Construction of RCC Machinehole chambers of 1:1.5:3 proportion
or approved type Cast-insitu / Pre-cast RCC Machinehole chambers,
constructed using form vibrators of standard type, with barricading,
danger lighting and using of sight rails and boning rods wherever
necessary, shoring and strutting wherever required using Ordinary
Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down
graded jelly, well graded sand and steel of approved quality, 200 mm
thick top concrete slab, having wall thickness and raft thickness as in
approved drawings and with an offset in raft alround the chamber as
in approved drawing, benching concrete with 1:6 slope towards the
central drain finished smooth, including fixing and grouting of pipes,
including conveying to work spot supply and fixing SFRC Machinehole
cover and frame (Heavy duty) conforming to IS:12592 with latest
amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3
mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia.
Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as
detailed in Technical specifications, including stone grit beding wherever
required, watering, curing, engraving Machinehole number with flow
direction on the inner cylindrical surface etc., complete including
cost of reinforcement steel and fabrication charges and also cost and
conveyance of all materials, labour with all lead and lifts. The Pre-cast
RCC Machinehole are for various diamters and depths as stated below
and as per detailed drawings, specifications and direction of the Engineer.
For 1.2m dia Machinehole:"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 97246.63 | 97246.63 | 1.0 | False | None | None | False | None | False | 97246.63 | 0 | 3610958 | 131241 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
External & Shafts & Terrace
40mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 80.0 | False | None | None | False | None | False | 47280.0 | 0 | 3610959 | 131241 | None | 13.23 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g)
T.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1665.22 | 1665.22 | 5.0 | False | None | None | False | None | False | 8326.1 | 0 | 3610960 | 131241 | None | 13.40.1 V-5 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 19340.79 | 19340.79 | 2.0 | False | None | None | False | None | False | 38681.58 | 0 | 3610961 | 131241 | None | 13.32 V-5 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and
equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 8053.5 | 8053.5 | 2.0 | False | None | None | False | None | False | 16107.0 | 0 |
| 1721828234000 | 0 | None | None | Buildings | MUDNOOR IN SHORAPUR TALUK OF YADGIR DISTRICT (ELECTRICAL WORKS) | 4364380.98 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3610962 | 131242 | None | PWD ELE SR V-6 IT.NO 2.2.1 | WIRES & CABLES
Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Short point up to 3Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 333.29 | 333.29 | 25.0 | False | None | None | False | None | False | 8332.25 | 0 | 3610963 | 131242 | None | PWD ELE SR V-10 IT.NO 2.2.2 | Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Pack | 469.58 | 469.58 | 36.0 | False | None | None | False | None | False | 16904.88 | 0 | 3610964 | 131242 | None | PWD ELE SR V-11 IT.NO 2.2.3 | Point wiring using Copper wire without switch.
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Long point above 6Mtr up to 10Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 687.65 | 687.65 | 63.0 | False | None | None | False | None | False | 43321.95 | 0 | 3610965 | 131242 | None | PWD ELE SR V-12 IT.NO 2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 838.8 | 838.8 | 8.0 | False | None | None | False | None | False | 6710.4 | 0 | 3610966 | 131242 | None | PWD ELE SR V-14 IT.NO 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
1-3Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 170.98 | 170.98 | 25.0 | False | None | None | False | None | False | 4274.5 | 0 | 3610967 | 131242 | None | PWD ELE SR V-15 IT.NO 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
4-5Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 197.0 | 197.0 | 32.0 | False | None | None | False | None | False | 6304.0 | 0 | 3610968 | 131242 | None | PWD ELE SR V-16 IT.NO 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
6Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 219.3 | 219.3 | 16.0 | False | None | None | False | None | False | 3508.8 | 0 | 3610969 | 131242 | None | PWD ELE SR V-17 IT.NO 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
8 Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 272.58 | 272.58 | 7.0 | False | None | None | False | None | False | 1908.06 | 0 | 3610970 | 131242 | None | PWD ELE SR V-18 IT.NO 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
10-12Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 323.38 | 323.38 | 20.0 | False | None | None | False | None | False | 6467.6 | 0 | 3610971 | 131242 | None | PWD ELE SR V-20 IT.NO 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
1 to 3 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 199.48 | 199.48 | 32.0 | False | None | None | False | None | False | 6383.36 | 0 | 3610972 | 131242 | None | PWD ELE SR V-21 IT.NO 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
4 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 216.83 | 216.83 | 16.0 | False | None | None | False | None | False | 3469.28 | 0 | 3610973 | 131242 | None | PWD ELE SR V-22 IT.NO 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
6 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 289.93 | 289.93 | 7.0 | False | None | None | False | None | False | 2029.51 | 0 | 3610974 | 131242 | None | PWD ELE SR V-23 IT.NO 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
8 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 351.88 | 351.88 | 21.0 | False | None | None | False | None | False | 7389.48 | 0 | 3610975 | 131242 | None | PWD ELE SR V-24 IT.NO 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
10-12 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 426.22 | 426.22 | 31.0 | False | None | None | False | None | False | 13212.82 | 0 | 3610976 | 131242 | None | PWD ELE SR V-26 IT.NO 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps one way Switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 126.38 | 126.38 | 217.0 | False | None | None | False | None | False | 27424.46 | 0 | 3610977 | 131242 | None | PWD ELE SR V-6 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps Two way Switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 205.67 | 205.67 | 2.0 | False | None | None | False | None | False | 411.34 | 0 | 3610978 | 131242 | None | PWD ELE SR V-6,IT.NO 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps 3way socket
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 211.87 | 211.87 | 81.0 | False | None | None | False | None | False | 17161.47 | 0 | 3610979 | 131242 | None | PWD ELE SR V-6,IT.NO 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Stepped Fan Regulator.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 442.32 | 442.32 | 24.0 | False | None | None | False | None | False | 10615.68 | 0 | 3610980 | 131242 | None | PWD ELE SR V-6,IT.NO 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
16Amps one way switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 223.02 | 223.02 | 10.0 | False | None | None | False | None | False | 2230.2 | 0 | 3610981 | 131242 | None | PWD ELE SR V-6, IT.NO 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
32Amps DP switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 403.91 | 403.91 | 15.0 | False | None | None | False | None | False | 6058.65 | 0 | 3610982 | 131242 | None | PWD ELE SR V-6,IT.NO 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6/16Amps universal socket
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 292.4 | 292.4 | 25.0 | False | None | None | False | None | False | 7310.0 | 0 | 3610983 | 131242 | None | PWD ELE SR V-6,IT.NO 1.13 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Supplyin and Fixing Metal Fan Box with Round Hook.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 144.96 | 144.96 | 24.0 | False | None | None | False | None | False | 3479.04 | 0 | 3610984 | 131242 | None | PWD ELE SR V-6,IT.NO-1.2.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
19/20mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 81.77 | 81.77 | 890.0 | False | None | None | False | None | False | 72775.3 | 0 | 3610985 | 131242 | None | PWD ELE SR V-6,IT.NO 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
25mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 96.64 | 96.64 | 1030.0 | False | None | None | False | None | False | 99539.2 | 0 | 3610986 | 131242 | None | PWD ELE SR V-6, IT.NO .2.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
32mm dia 2.5mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 127.62 | 127.62 | 250.0 | False | None | None | False | None | False | 31905.0 | 0 | 3610987 | 131242 | None | PWD ELE SR V-6,IT.NO1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
19/20mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 84.25 | 84.25 | 445.0 | False | None | None | False | None | False | 37491.25 | 0 | 3610988 | 131242 | None | PWD ELE SR V-6,IT.NO-1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 97.88 | 97.88 | 515.0 | False | None | None | False | None | False | 50408.2 | 0 | 3610989 | 131242 | None | PWD ELE SR V-6,IT.NO-1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
32mm dia 2.5mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 122.66 | 122.66 | 150.0 | False | None | None | False | None | False | 18399.0 | 0 | 3610990 | 131242 | None | PWD ELE SR V-6,IT.NO 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 32.21 | 32.21 | 470.0 | False | None | None | False | None | False | 15138.7 | 0 | 3610991 | 131242 | None | PWD ELE SR V-6,IT.NO 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 52.04 | 52.04 | 1530.0 | False | None | None | False | None | False | 79621.2 | 0 | 3610992 | 131242 | None | PWD ELE SR V-6,IT.NO 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
4 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 78.06 | 78.06 | 740.0 | False | None | None | False | None | False | 57764.4 | 0 | 3610993 | 131242 | None | PWD ELE SR V-6,IT.NO 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
6 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 113.99 | 113.99 | 580.0 | False | None | None | False | None | False | 66114.2 | 0 | 3610994 | 131242 | None | PWD ELE SR V-6,IT.NO 5.19.11 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure
III - Double Door
4 Way TP & N
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 5003.08 | 5003.08 | 2.0 | False | None | None | False | None | False | 10006.16 | 0 | 3610995 | 131242 | None | PWD ELE SR V-6,IT.NO 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
6-32Amps SP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 514.19 | 514.19 | 62.0 | False | None | None | False | None | False | 31879.78 | 0 | 3610996 | 131242 | None | PWD ELE SR V-6 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
40Amps TPN
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3771.52 | 3771.52 | 2.0 | False | None | None | False | None | False | 7543.04 | 0 | 3610997 | 131242 | None | PWD ELE SR V-6,IT.NO 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board
16-25 Amps 2 pole
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 5299.2 | 5299.2 | 2.0 | False | None | None | False | None | False | 10598.4 | 0 | 3610998 | 131242 | None | PWD ELE SR V-6,IT.NO 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only)
32mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 480.73 | 480.73 | 10.0 | False | None | None | False | None | False | 4807.3 | 0 | 3610999 | 131242 | None | PWD ELE SR V-6,IT.NO 6.17.8 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.
35 sqmm Long Barrel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 39.65 | 39.65 | 16.0 | False | None | None | False | None | False | 634.4 | 0 | 3611000 | 131242 | None | V-6 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4348.89 | 4348.89 | 7.0 | False | None | None | False | None | False | 30442.23 | 0 | 3611001 | 131242 | None | V-6 12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x3mm GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 101.6 | 101.6 | 100.0 | False | None | None | False | None | False | 10160.0 | 0 | 3611002 | 131242 | None | 12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
600X600X3 GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1084.13 | 1084.13 | 6.0 | False | None | None | False | None | False | 6504.78 | 0 | 3611003 | 131242 | None | 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1096.52 | 1096.52 | 19.0 | False | None | None | False | None | False | 20833.88 | 0 | 3611004 | 131242 | None | 11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1640.44 | 1640.44 | 5.0 | False | None | None | False | None | False | 8202.2 | 0 | 3611005 | 131242 | None | 11.3.2 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 854.91 | 854.91 | 51.0 | False | None | None | False | None | False | 43600.41 | 0 | 3611006 | 131242 | None | 11.11.3 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 184.61 | 184.61 | 15.0 | False | None | None | False | None | False | 2769.15 | 0 | 3611007 | 131242 | None | PWD ELE SR V-6,IT.NO 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1848.59 | 1848.59 | 13.0 | False | None | None | False | None | False | 24031.67 | 0 | 3611008 | 131242 | None | PWD ELE SR V-6,IT.NO 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3316.8 | 3316.8 | 24.0 | False | None | None | False | None | False | 79603.2 | 0 | 3611009 | 131242 | None | PWD ELE SR V-6,IT.NO 13.11 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.
On wall / ceiling / Rafter / Girders
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 390.29 | 390.29 | 24.0 | False | None | None | False | None | False | 9366.96 | 0 | 3611010 | 131242 | None | PWD ELE SR V-6,IT.NO 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 151.16 | 151.16 | 83.0 | False | None | None | False | None | False | 12546.28 | 0 | 3611011 | 131242 | None | PWD ELE SR V-6,IT.NO 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 875.97 | 875.97 | 13.0 | False | None | None | False | None | False | 11387.61 | 0 | 3611012 | 131242 | None | PWD ELE SR V-6,IT.NO 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 200.72 | 200.72 | 3.0 | False | None | None | False | None | False | 602.16 | 0 | 3611013 | 131242 | None | PWD ELE SR V-6,IT.NO 5.42.1 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete
16SWG
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 86000.0 | False | None | None | False | None | False | 45580.0 | 0 | 3611014 | 131242 | None | PWD ELE SR V-6,IT.NO 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 4255.97 | 4255.97 | 5.0 | False | None | None | False | None | False | 21279.85 | 0 | 3611015 | 131242 | None | PWD ELE SR V-6,IT.NO 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
40x40x6mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 377.9 | 377.9 | 10.0 | False | None | None | False | None | False | 3779.0 | 0 | 3611016 | 131242 | None | PWD ELE SR V-6,IT.NO 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
50x100x50x6mm C channel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 936.68 | 936.68 | 10.0 | False | None | None | False | None | False | 9366.8 | 0 | 3611017 | 131242 | None | PWD ELE SR V-6,IT.NO 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs)
100Amps 25kA
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 10515.39 | 10515.39 | 1.0 | False | None | None | False | None | False | 10515.39 | 0 | 3611018 | 131242 | None | PWD ELE SR V-6,iT.NO 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
50-63Amps DP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3826.03 | 3826.03 | 10.0 | False | None | None | False | None | False | 38260.3 | 0 | 3611019 | 131242 | None | PWD ELE SR V-6,IT.NO 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 11541.29 | 11541.29 | 1.0 | False | None | None | False | None | False | 11541.29 | 0 | 3611020 | 131242 | None | PWD ELE SR V-6,IT.NO 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3611021 | 131242 | None | PWD ELE SR V-6,IT.NO 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 696.32 | 696.32 | 3.0 | False | None | None | False | None | False | 2088.96 | 0 | 3611022 | 131242 | None | PWD ELE SR V-6,IT.NO5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kvar | 594.72 | 594.72 | 15.0 | False | None | None | False | None | False | 8920.8 | 0 | 3611023 | 131242 | None | 5.19.9 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2885.63 | 2885.63 | 2.0 | False | None | None | False | None | False | 5771.26 | 0 | 3611024 | 131242 | None | 5.19.12 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6120.66 | 6120.66 | 1.0 | False | None | None | False | None | False | 6120.66 | 0 | 3611025 | 131242 | None | 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3826.03 | 3826.03 | 1.0 | False | None | None | False | None | False | 3826.03 | 0 | 3611026 | 131242 | None | 5.20.8 | Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6377.13 | 6377.13 | 3.0 | False | None | None | False | None | False | 19131.39 | 0 | 3611027 | 131242 | None | 32.05 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 109549.9 | 109549.9 | 0.1 | False | None | None | False | None | False | 10954.99 | 0 | 3611028 | 131242 | None | 32.09 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 190882.82 | 190882.82 | 0.05 | False | None | None | False | None | False | 9544.141 | 0 | 3611029 | 131242 | None | 32.13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 393892.97 | 393892.97 | 0.1 | False | None | None | False | None | False | 39389.297 | 0 | 3611030 | 131242 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 25877.75 | 25877.75 | 0.05 | False | None | None | False | None | False | 1293.8875 | 0 | 3611031 | 131242 | None | 31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 38581.22 | 38581.22 | 0.2 | False | None | None | False | None | False | 7716.244 | 0 | 3611032 | 131242 | None | 6.17.6 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 15.41 | 15.41 | 20.0 | False | None | None | False | None | False | 308.2 | 0 | 3611033 | 131242 | None | 16.17.10 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 148.68 | 148.68 | 16.0 | False | None | None | False | None | False | 2378.88 | 0 | 3611034 | 131242 | None | 11.11.5 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 333.29 | 333.29 | 9.0 | False | None | None | False | None | False | 2999.61 | 0 | 3611035 | 131242 | None | 11.6.3 | Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 5641.17 | 5641.17 | 8.0 | False | None | None | False | None | False | 45129.36 | 0 | 3611036 | 131242 | None | 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4985.74 | 4985.74 | 2.0 | False | None | None | False | None | False | 9971.48 | 0 | 3611037 | 131242 | None | 13.4.1 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1810.18 | 1810.18 | 3.0 | False | None | None | False | None | False | 5430.54 | 0 | 3611038 | 131242 | None | 5.14.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 2738.19 | 2738.19 | 2.0 | False | None | None | False | None | False | 5476.38 | 0 | 3611039 | 131242 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 169.74 | 169.74 | 24.0 | False | None | None | False | None | False | 4073.76 | 0 | 3611040 | 131242 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 395.24 | 395.24 | 31.0 | False | None | None | False | None | False | 12252.44 | 0 | 3611041 | 131242 | None | 2.2.5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 1225.37 | 1225.37 | 4.0 | False | None | None | False | None | False | 4901.48 | 0 | 3611042 | 131242 | None | 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 144.96 | 144.96 | 6.0 | False | None | None | False | None | False | 869.76 | 0 | 3611043 | 131242 | None | 12.46 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 78.06 | 78.06 | 21.0 | False | None | None | False | None | False | 1639.26 | 0 | 3611044 | 131242 | None | 3.6.11 | TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 193.28 | 193.28 | 2.0 | False | None | None | False | None | False | 386.56 | 0 | 3611045 | 131242 | None | 12.2.1 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 304.79 | 304.79 | 1.0 | False | None | None | False | None | False | 304.79 | 0 | 3611046 | 131242 | None | 32.02 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 98168.45 | 98168.45 | 0.1 | False | None | None | False | None | False | 9816.845 | 0 | 3611047 | 131242 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 25877.75 | 25877.75 | 0.1 | False | None | None | False | None | False | 2587.775 | 0 | 3611048 | 131242 | None | pwd sr | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 15.41 | 15.41 | 15.0 | False | None | None | False | None | False | 231.15 | 0 | 3611049 | 131242 | None | 11..11.7 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 527.81 | 527.81 | 3.0 | False | None | None | False | None | False | 1583.43 | 0 | 3611050 | 131242 | None | 12.27 | Supplying & Fixing of Special Type pigmy and candle lamp.
Operating voltage range from 180V to 265V, 50Hz AC power Supply"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 64.43 | 64.43 | 2.0 | False | None | None | False | None | False | 128.86 | 0 | 3611051 | 131242 | None | 11.8.1 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3004.58 | 3004.58 | 1.0 | False | None | None | False | None | False | 3004.58 | 0 | 3611052 | 131242 | None | 5.7.2 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 298.6 | 298.6 | 1.0 | False | None | None | False | None | False | 298.6 | 0 | 3611053 | 131242 | None | 5.30 | Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1709.82 | 1709.82 | 1.0 | False | None | None | False | None | False | 1709.82 | 0 | 3611054 | 131242 | None | 7.1.3 | Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 12689.84 | 12689.84 | 1.0 | False | None | None | False | None | False | 12689.84 | 0 | 3611055 | 131242 | None | PWD SR 2023-24 Volume 6 It No-9.3.3 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 84726.54 | 84726.54 | 1.0 | False | None | None | False | None | False | 84726.54 | 0 | 3611056 | 131242 | None | PWD SR 2023-24 Volume 6 It No-9.5.9 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 19693.91 | 19693.91 | 4.0 | False | None | None | False | None | False | 78775.64 | 0 | 3611057 | 131242 | None | A.R | Item Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 300000.0 | 300000.0 | 1.0 | False | None | None | False | None | False | 300000.0 | 0 | 3611058 | 131242 | None | LQR | IP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 23836.0 | 23836.0 | 4.0 | False | None | None | False | None | False | 95344.0 | 0 | 3611059 | 131242 | None | LQR | IP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 25606.0 | 25606.0 | 2.0 | False | None | None | False | None | False | 51212.0 | 0 | 3611060 | 131242 | None | LQR | Supplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3611061 | 131242 | None | LQR | Supply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 17110.0 | 17110.0 | 2.0 | False | None | None | False | None | False | 34220.0 | 0 | 3611062 | 131242 | None | LQR | Supply and Installation of I/Os
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 147.5 | 147.5 | 12.0 | False | None | None | False | None | False | 1770.0 | 0 | 3611063 | 131242 | None | LQR | Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 265.5 | 265.5 | 12.0 | False | None | None | False | None | False | 3186.0 | 0 | 3611064 | 131242 | None | LQR | Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 336.3 | 336.3 | 6.0 | False | None | None | False | None | False | 2017.8 | 0 | 3611065 | 131242 | None | LQR | Supply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3611066 | 131242 | None | V-6 8.1 | Supplying and drawing UTP-CAT 6E LAN cable
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 47.08 | 47.08 | 600.0 | False | None | None | False | None | False | 28248.0 | 0 | 3611067 | 131242 | None | 1.2.2 | Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 96.64 | 96.64 | 500.0 | False | None | None | False | None | False | 48320.0 | 0 | 3611068 | 131242 | None | 8.12.3 | Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3778.95 | 3778.95 | 1.0 | False | None | None | False | None | False | 3778.95 | 0 | 3611069 | 131242 | None | 8.4.1 v-6 | Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 6061.19 | 6061.19 | 1.0 | False | None | None | False | None | False | 6061.19 | 0 | 3611070 | 131242 | None | 1.01 | Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 8767.16 | 8767.16 | 8.0 | False | None | None | False | None | False | 70137.28 | 0 | 3611071 | 131242 | None | 2.02 | Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 1379.01 | 1379.01 | 8.0 | False | None | None | False | None | False | 11032.08 | 0 | 3611072 | 131242 | None | 6.05 | Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 107.79 | 107.79 | 6.0 | False | None | None | False | None | False | 646.74 | 0 | 3611073 | 131242 | None | 13.12 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 59.47 | 59.47 | 6.0 | False | None | None | False | None | False | 356.82 | 0 | 3611074 | 131242 | None | 2.16 | Supply of Spiral Earth Electrode
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 296.12 | 296.12 | 11.0 | False | None | None | False | None | False | 3257.32 | 0 | 3611075 | 131242 | None | 2.16 | Erection of Spiral Earth Electrode
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 115.23 | 115.23 | 11.0 | False | None | None | False | None | False | 1267.53 | 0 | 3611076 | 131242 | None | 68.17 | Supply and fixing of Caution/Danger Board
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 185.85 | 185.85 | 6.0 | False | None | None | False | None | False | 1115.1 | 0 | 3611077 | 131242 | None | 4.02 | Supply of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 110.27 | 110.27 | 8.0 | False | None | None | False | None | False | 882.16 | 0 | 3611078 | 131242 | None | 5.09 | Erection of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 52.04 | 52.04 | 8.0 | False | None | None | False | None | False | 416.32 | 0 | 3611079 | 131242 | None | 24.05 | Supply and fixing of 11 kV, 400 Amps Double Break GOS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 26341.14 | 26341.14 | 1.0 | False | None | None | False | None | False | 26341.14 | 0 | 3611080 | 131242 | None | 24.07 | Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 7521.97 | 7521.97 | 1.0 | False | None | None | False | None | False | 7521.97 | 0 | 3611081 | 131242 | None | 25.01 | Supply of DOLO Cut Out
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set of 3 Nos | 7279.13 | 7279.13 | 1.0 | False | None | None | False | None | False | 7279.13 | 0 | 3611082 | 131242 | None | 13.01 | Erection of DOLO Cut Out
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set of 3 Nos | 293.64 | 293.64 | 1.0 | False | None | None | False | None | False | 293.64 | 0 | 3611083 | 131242 | None | 13.07 | Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 210958.34 | 210958.34 | 1.0 | False | None | None | False | None | False | 210958.34 | 0 | 3611084 | 131242 | None | 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 4348.89 | 4348.89 | 8.0 | False | None | None | False | None | False | 34791.12 | 0 | 3611085 | 131242 | None | 12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | MT | 158.59 | 158.59 | 100.0 | False | None | None | False | None | False | 15859.0 | 0 | 3611086 | 131242 | None | 12.58.9 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 2035.68 | 2035.68 | 100.0 | False | None | None | False | None | False | 203568.0 | 0 | 3611087 | 131242 | None | 12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 9194.62 | 9194.62 | 10.0 | False | None | None | False | None | False | 91946.2 | 0 | 3611088 | 131242 | None | 45.07 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 5039.01 | 5039.01 | 4.0 | False | None | None | False | None | False | 20156.04 | 0 | 3611089 | 131242 | None | 45.04 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 3887.98 | 3887.98 | 2.0 | False | None | None | False | None | False | 7775.96 | 0 | 3611090 | 131242 | None | 36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 1102296.17 | 1102296.17 | 0.1 | False | None | None | False | None | False | 110229.617 | 0 | 3611091 | 131242 | None | 38. | Providing chain link fencing 50 mm size of 8 guage properly stretched between
rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be
welded to the Pole and block pipe at top and bottom as required including cost
of all materials, labour, lead and lifts, cutting, bending wherever necessary,
wastage and lapping etc., complete as per the direction of the engineer
incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1222.89 | 1222.89 | 150.0 | False | None | None | False | None | False | 183433.5 | 0 | 3611092 | 131242 | None | 5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 176000.0 | False | None | None | False | None | False | 93280.0 | 0 | 3611093 | 131242 | None | 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 4255.97 | 4255.97 | 6.0 | False | None | None | False | None | False | 25535.82 | 0 | 3611094 | 131242 | None | 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 377.9 | 377.9 | 12.0 | False | None | None | False | None | False | 4534.8 | 0 | 3611095 | 131242 | None | 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 936.68 | 936.68 | 12.0 | False | None | None | False | None | False | 11240.16 | 0 | 3611096 | 131242 | None | 5.15.15 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 29172.26 | 29172.26 | 1.0 | False | None | None | False | None | False | 29172.26 | 0 | 3611097 | 131242 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3611098 | 131242 | None | 10.1.3 | Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have +
1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating
lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting
battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr
at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 558914.14 | 558914.14 | 1.0 | False | None | None | False | None | False | 558914.14 | 0 | 3611099 | 131242 | None | 10.2.2 | Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the
accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 72742.93 | 72742.93 | 1.0 | False | None | None | False | None | False | 72742.93 | 0 | 3611100 | 131242 | None | A.R | Supply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 3540.0 | 3540.0 | 5.0 | False | None | None | False | None | False | 17700.0 | 0 | 3611101 | 131242 | None | A.R | Supply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 236.0 | 236.0 | 50.0 | False | None | None | False | None | False | 11800.0 | 0 | 3611102 | 131242 | None | 58.02 | LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 98973.8 | 98973.8 | 1.0 | False | None | None | False | None | False | 98973.8 | 0 | 3611103 | 131242 | None | 53.01 | CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 24302.99 | 24302.99 | 1.0 | False | None | None | False | None | False | 24302.99 | 0 | 3611104 | 131242 | None | 10.01 | Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 173.46 | 173.46 | 15.0 | False | None | None | False | None | False | 2601.9 | 0 | 3611105 | 131242 | None | v-6 2.02 | Supply of 11 kV, Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr
Long, 145 Kg WL"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 603.39 | 603.39 | 6.0 | False | None | None | False | None | False | 3620.34 | 0 | 3611106 | 131242 | None | v-6 2.02 | Erection of 11 kV, Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr
Long, 145 Kg WL"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 318.42 | 318.42 | 6.0 | False | None | None | False | None | False | 1910.52 | 0 | 3611107 | 131242 | None | v-6 6.06 | Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP
Rod) "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 254.0 | 254.0 | 18.0 | False | None | None | False | None | False | 4572.0 | 0 | 3611108 | 131242 | None | v-6 6.10 | Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 235.45 | 235.45 | 18.0 | False | None | None | False | None | False | 4238.1 | 0 | 3611109 | 131242 | None | 13.12 v-6 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 59.47 | 59.47 | 18.0 | False | None | None | False | None | False | 1070.46 | 0 | 3611110 | 131242 | None | v-6 6.08 | Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 73.1 | 73.1 | 4.0 | False | None | None | False | None | False | 292.4 | 0 | 3611111 | 131242 | None | 7.02 | Supply of Rabbit ACSR Conductor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 57283.93 | 57283.93 | 1.0 | False | None | None | False | None | False | 57283.93 | 0 | 3611112 | 131242 | None | 6.02 V-6 | Erection of Rabbit ACSR Conductor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 5403.28 | 5403.28 | 1.0 | False | None | None | False | None | False | 5403.28 | 0 |
| 1721828234000 | 0 | None | None | Buildings | HEGGANDODDI IN SHORAPUR TALUK OF YADGIR DISTRICT | 34812473.11 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3611113 | 131243 | None | CSR:V-3 PAGE NO 9 Itm 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | 100 Sqm | 486.93 | 486.93 | 17.09 | False | None | None | False | None | False | 8321.6337 | 0 | 3611114 | 131243 | None | V-1 page 8 itm 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 117.71 | 117.71 | 540.95 | False | None | None | False | None | False | 63675.2245 | 0 | 3611115 | 131243 | None | V-1page 8 itm 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 126.38 | 126.38 | 1430.43 | False | None | None | False | None | False | 180777.7434 | 0 | 3611116 | 131243 | None | V-1page 8 itm 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 449.76 | 449.76 | 254.05 | False | None | None | False | None | False | 114261.528 | 0 | 3611117 | 131243 | None | V-3page 3 A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 167.27 | 167.27 | 218.94 | False | None | None | False | None | False | 36622.0938 | 0 | 3611118 | 131243 | None | V-2page5 itm 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 146.2 | 146.2 | 774.16 | False | None | None | False | None | False | 113182.192 | 0 | 3611119 | 131243 | None | V-1pg7 itm1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 329.57 | 329.57 | 901.41 | False | None | None | False | None | False | 297077.6937 | 0 | 3611120 | 131243 | None | V-1page7vitm1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 587.29 | 587.29 | 747.04 | False | None | None | False | None | False | 438729.1216 | 0 | 3611121 | 131243 | None | V-1page 15 itm2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7420.37 | 7420.37 | 155.33 | False | None | None | False | None | False | 1152606.0721 | 0 | 3611122 | 131243 | None | V-1page15 itm 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8478.33 | 8478.33 | 177.95 | False | None | None | False | None | False | 1508718.8235 | 0 | 3611123 | 131243 | None | V-1page16 itm 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8635.33 | 8635.33 | 13.4 | False | None | None | False | None | False | 115713.422 | 0 | 3611124 | 131243 | None | V-1page15itm 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 14413.41 | 14413.41 | 57.58 | False | None | None | False | None | False | 829924.1478 | 0 | 3611125 | 131243 | None | V-3page135itm15.4 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 252.76 | 252.76 | 13.0 | False | None | None | False | None | False | 3285.88 | 0 | 3611126 | 131243 | None | V-2page55 itm 8.16.a | Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1533.88 | 1533.88 | 13.81 | False | None | None | False | None | False | 21182.8828 | 0 | 3611127 | 131243 | None | V-1page18itm2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Tonne | 110837.22 | 110837.22 | 50.59 | False | None | None | False | None | False | 5607254.9598 | 0 | 3611128 | 131243 | None | 18-19SR ITM4.21 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 38.94 | 38.94 | 145.02 | False | None | None | False | None | False | 5647.0788 | 0 | 3611129 | 131243 | None | DATA RATE | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 86.14 | 86.14 | 145.02 | False | None | None | False | None | False | 12492.0228 | 0 | 3611130 | 131243 | None | V-2PAGE 9 ITM5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7915.97 | 7915.97 | 8.76 | False | None | None | False | None | False | 69343.8972 | 0 | 3611131 | 131243 | None | V-2PAGE 14 ITM 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1623.09 | 1623.09 | 1253.93 | False | None | None | False | None | False | 2035241.2437 | 0 | 3611132 | 131243 | None | V-2page 14 itm 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks
of size 400x100x200mm having block density more than 1800kg/m3
and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005
including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1367.86 | 1367.86 | 171.24 | False | None | None | False | None | False | 234232.3464 | 0 | 3611133 | 131243 | None | V-2 page100 itm 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 122431.79 | 122431.79 | 1.2 | False | None | None | False | None | False | 146918.148 | 0 | 3611134 | 131243 | None | V-2 page 105 itm 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 1258.82 | 1258.82 | 32.0 | False | None | None | False | None | False | 40282.24 | 0 | 3611135 | 131243 | None | 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 681.45 | 681.45 | 64.0 | False | None | None | False | None | False | 43612.8 | 0 | 3611136 | 131243 | None | 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 464.63 | 464.63 | 32.0 | False | None | None | False | None | False | 14868.16 | 0 | 3611137 | 131243 | None | 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 185.85 | 185.85 | 64.0 | False | None | None | False | None | False | 11894.4 | 0 | 3611138 | 131243 | None | 22.15.9 | PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 86.73 | 86.73 | 128.0 | False | None | None | False | None | False | 11101.44 | 0 | 3611139 | 131243 | None | 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 123.9 | 123.9 | 32.0 | False | None | None | False | None | False | 3964.8 | 0 | 3611140 | 131243 | None | 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 1303.43 | 1303.43 | 32.0 | False | None | None | False | None | False | 41709.76 | 0 | 3611141 | 131243 | None | V-2page69 itm 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 74.34 | 74.34 | 192.0 | False | None | None | False | None | False | 14273.28 | 0 | 3611142 | 131243 | None | 20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 64.43 | 64.43 | 168.45 | False | None | None | False | None | False | 10853.2335 | 0 | 3611143 | 131243 | None | V-2page105 itm 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4115.96 | 4115.96 | 74.84 | False | None | None | False | None | False | 308038.4464 | 0 | 3611144 | 131243 | None | V-2page109 itm 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 8343.43 | 8343.43 | 69.39 | False | None | None | False | None | False | 578950.6077 | 0 | 3611145 | 131243 | None | V-2page109 itm 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 7085.84 | 7085.84 | 6.84 | False | None | None | False | None | False | 48467.1456 | 0 | 3611146 | 131243 | None | V-2page 86itm11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 208.15 | 208.15 | 1600.83 | False | None | None | False | None | False | 333212.7645 | 0 | 3611147 | 131243 | None | V-2page 111itm 12.93.1 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/
cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | m | 869.78 | 869.78 | 64.35 | False | None | None | False | None | False | 55970.343 | 0 | 3611148 | 131243 | None | V-2page84 itm 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kgs | 168.5 | 168.5 | 1724.91 | False | None | None | False | None | False | 290647.335 | 0 | 3611149 | 131243 | None | V-2page 41itm 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 386.57 | 386.57 | 1763.82 | False | None | None | False | None | False | 681839.8974 | 0 | 3611150 | 131243 | None | V-2page 43 itm 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 261.43 | 261.43 | 1176.83 | False | None | None | False | None | False | 307658.6669 | 0 | 3611151 | 131243 | None | V-2page50 itm 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 123.9 | 123.9 | 2919.03 | False | None | None | False | None | False | 361667.817 | 0 | 3611152 | 131243 | None | V-2page42itm 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 432.41 | 432.41 | 975.48 | False | None | None | False | None | False | 421807.3068 | 0 | 3611153 | 131243 | None | V-2page41 itm 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 438.61 | 438.61 | 163.05 | False | None | None | False | None | False | 71515.3605 | 0 | 3611154 | 131243 | None | 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 47.08 | 47.08 | 2013.85 | False | None | None | False | None | False | 94812.058 | 0 | 3611155 | 131243 | None | 10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 254.88 | 254.88 | 13.0 | False | None | None | False | None | False | 3313.44 | 0 | 3611156 | 131243 | None | V-2page 54itm 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 64.43 | 64.43 | 628.05 | False | None | None | False | None | False | 40465.2615 | 0 | 3611157 | 131243 | None | V-2page61itm 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1455.83 | 1455.83 | 580.89 | False | None | None | False | None | False | 845677.0887 | 0 | 3611158 | 131243 | None | V-2page59 itm9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 991.2 | 991.2 | 71.5 | False | None | None | False | None | False | 70870.8 | 0 | 3611159 | 131243 | None | V-2page63 itm 9.32 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3199.1 | 3199.1 | 34.54 | False | None | None | False | None | False | 110496.914 | 0 | 3611160 | 131243 | None | V-2page 4 itm 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 365.51 | 365.51 | 316.07 | False | None | None | False | None | False | 115526.7457 | 0 | 3611161 | 131243 | None | V-2page 60 itm 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1101.47 | 1101.47 | 59.14 | False | None | None | False | None | False | 65140.9358 | 0 | 3611162 | 131243 | None | V-2page65 itmv9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1795.31 | 1795.31 | 259.57 | False | None | None | False | None | False | 466008.6167 | 0 | 3611163 | 131243 | None | V-2 page85 itm11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 700.04 | 700.04 | 357.82 | False | None | None | False | None | False | 250488.3128 | 0 | 3611164 | 131243 | None | V-2 page 48itm 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 157.35 | 157.35 | 2741.14 | False | None | None | False | None | False | 431318.379 | 0 | 3611165 | 131243 | None | V-2page 46itm8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 193.28 | 193.28 | 759.66 | False | None | None | False | None | False | 146827.0848 | 0 | 3611166 | 131243 | None | V-2page47 itm8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 61.95 | 61.95 | 96.21 | False | None | None | False | None | False | 5960.2095 | 0 | 3611167 | 131243 | None | V-2page48 itm 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 142.49 | 142.49 | 76.23 | False | None | None | False | None | False | 10862.0127 | 0 | 3611168 | 131243 | None | V-2page47itm 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 65.67 | 65.67 | 179.6 | False | None | None | False | None | False | 11794.332 | 0 | 3611169 | 131243 | None | 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 838.8 | 838.8 | 179.6 | False | None | None | False | None | False | 150648.48 | 0 | 3611170 | 131243 | None | V-2page64itm 9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 2044.35 | 2044.35 | 17.32 | False | None | None | False | None | False | 35408.142 | 0 | 3611171 | 131243 | None | V-2page77 itm 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 5548.24 | 5548.24 | 5.25 | False | None | None | False | None | False | 29128.26 | 0 | 3611172 | 131243 | None | 15.12 | Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1443.44 | 1443.44 | 726.5 | False | None | None | False | None | False | 1048659.16 | 0 | 3611173 | 131243 | None | V-2PAGE22 ITM 7.17 | Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 411.35 | 411.35 | 24.74 | False | None | None | False | None | False | 10176.799 | 0 | 3611174 | 131243 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 94.35 | False | None | None | False | None | False | 1199916.882 | 0 | 3611175 | 131243 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 13565.56 | 13565.56 | 51.01 | False | None | None | False | None | False | 691979.2156 | 0 | 3611176 | 131243 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 115.4 | False | None | None | False | None | False | 1467624.888 | 0 | 3611177 | 131243 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 7.07 | False | None | None | False | None | False | 89914.2804 | 0 | 3611178 | 131243 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 13565.56 | 13565.56 | 12.12 | False | None | None | False | None | False | 164414.5872 | 0 | 3611179 | 131243 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 11911.13 | 11911.13 | 14.18 | False | None | None | False | None | False | 168899.8234 | 0 | 3611180 | 131243 | None | 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4317.92 | 4317.92 | 20.48 | False | None | None | False | None | False | 88431.0016 | 0 | 3611181 | 131243 | None | 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 141.25 | 141.25 | 36.0 | False | None | None | False | None | False | 5085.0 | 0 | 3611182 | 131243 | None | 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1642.91 | 1642.91 | 56.5 | False | None | None | False | None | False | 92824.415 | 0 | 3611183 | 131243 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 6601.39 | 6601.39 | 30.54 | False | None | None | False | None | False | 201606.4506 | 0 | 3611184 | 131243 | None | 10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4877.94 | 4877.94 | 9.69 | False | None | None | False | None | False | 47267.2386 | 0 | 3611185 | 131243 | None | 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 761.99 | 761.99 | 92.01 | False | None | None | False | None | False | 70110.6999 | 0 | 3611186 | 131243 | None | 8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 350.64 | 350.64 | 215.82 | False | None | None | False | None | False | 75675.1248 | 0 | 3611187 | 131243 | None | 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 360.55 | 360.55 | 68.92 | False | None | None | False | None | False | 24849.106 | 0 | 3611188 | 131243 | None | 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3533.63 | 3533.63 | 11.09 | False | None | None | False | None | False | 39187.9567 | 0 | 3611189 | 131243 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 6601.39 | 6601.39 | 13.73 | False | None | None | False | None | False | 90637.0847 | 0 | 3611190 | 131243 | None | 10.1.1 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4963.43 | 4963.43 | 3.81 | False | None | None | False | None | False | 18910.6683 | 0 | 3611191 | 131243 | None | 1.4.1 V-1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 299.84 | 299.84 | 11.06 | False | None | None | False | None | False | 3316.2304 | 0 | 3611192 | 131243 | None | 1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 320.9 | 320.9 | 1.7 | False | None | None | False | None | False | 545.53 | 0 | 3611193 | 131243 | None | 17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1391.4 | 1391.4 | 7.0 | False | None | None | False | None | False | 9739.8 | 0 | 3611194 | 131243 | None | 17.1 V-2 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1241.48 | 1241.48 | 0.28 | False | None | None | False | None | False | 347.6144 | 0 | 3611195 | 131243 | None | 17.2 V-2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1469.45 | 1469.45 | 0.14 | False | None | None | False | None | False | 205.723 | 0 | 3611196 | 131243 | None | 17. V-2 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1476.89 | 1476.89 | 0.14 | False | None | None | False | None | False | 206.7646 | 0 | 3611197 | 131243 | None | 17.4 V-2 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1659.02 | 1659.02 | 0.14 | False | None | None | False | None | False | 232.2628 | 0 | 3611198 | 131243 | None | 17.14 V-2 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1449.63 | 1449.63 | 1.0 | False | None | None | False | None | False | 1449.63 | 0 | 3611199 | 131243 | None | V3 305.3.4 | Compacting Original Ground
Compacting original ground supporting embankment
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 130.1 | 130.1 | 60.0 | False | None | None | False | None | False | 7806.0 | 0 | 3611200 | 131243 | None | V-3 4.2 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 2922.8 | 2922.8 | 30.0 | False | None | None | False | None | False | 87684.0 | 0 | 3611201 | 131243 | None | V3 6.1 ISSUE RATE | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 6095.88 | 6095.88 | 20.0 | False | None | None | False | None | False | 121917.6 | 0 | 3611202 | 131243 | None | V-3 6.2 ISSUE RATE | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 11107.64 | 11107.64 | 40.0 | False | None | None | False | None | False | 444305.6 | 0 | 3611203 | 131243 | None | V-3 8.10 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 105.32 | 105.32 | 15.0 | False | None | None | False | None | False | 1579.8 | 0 | 3611204 | 131243 | None | V-3 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 87.97 | 87.97 | 448.0 | False | None | None | False | None | False | 39410.56 | 0 | 3611205 | 131243 | None | V-314621A | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)
300 x 250 x 100 mm Kerb Stone
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 296.12 | 296.12 | 100.0 | False | None | None | False | None | False | 29612.0 | 0 | 3611206 | 131243 | None | 2.1.4 V-1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7702.86 | 7702.86 | 1.2 | False | None | None | False | None | False | 9243.432 | 0 | 3611207 | 131243 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 9156.76 | 9156.76 | 6.48 | False | None | None | False | None | False | 59335.8048 | 0 | 3611208 | 131243 | None | 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 459.67 | 459.67 | 192.0 | False | None | None | False | None | False | 88256.64 | 0 | 3611209 | 131243 | None | 8.31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 220.54 | 220.54 | 192.0 | False | None | None | False | None | False | 42343.68 | 0 | 3611210 | 131243 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8761.09 | 8761.09 | 9.36 | False | None | None | False | None | False | 82003.8024 | 0 | 3611211 | 131243 | None | 8.20 V-3 | Providing and fixing 1.8 m high GI barbed wire fencing with
2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete,
0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 672.78 | 672.78 | 390.0 | False | None | None | False | None | False | 262384.2 | 0 | 3611212 | 131243 | None | V1 1.15.2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 526.58 | 526.58 | 22.51 | False | None | None | False | None | False | 11853.3158 | 0 | 3611213 | 131243 | None | 2.5.2 V1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8732.83 | 8732.83 | 4.32 | False | None | None | False | None | False | 37725.8256 | 0 | 3611214 | 131243 | None | 2.5.2 V1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 9326.32 | 9326.32 | 5.89 | False | None | None | False | None | False | 54932.0248 | 0 | 3611215 | 131243 | None | V2 15.14 | UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 2072.85 | 2072.85 | 36.6 | False | None | None | False | None | False | 75866.31 | 0 | 3611216 | 131243 | None | V5 18.3 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2430.92 | 2430.92 | 8.0 | False | None | None | False | None | False | 19447.36 | 0 | 3611217 | 131243 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 14413.41 | 14413.41 | 9.87 | False | None | None | False | None | False | 142260.3567 | 0 | 3611218 | 131243 | None | 15.5 V-2 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 749.6 | 749.6 | 63.57 | False | None | None | False | None | False | 47652.072 | 0 | 3611219 | 131243 | None | 8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 110.27 | 110.27 | 20.1 | False | None | None | False | None | False | 2216.427 | 0 | 3611220 | 131243 | None | V-5P140I12.4 | Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3611221 | 131243 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3611222 | 131243 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above 50 Mtrs and upto 100 Mtr
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3611223 | 131243 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above100 Mtrs. and upto 150 Mtr
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3611224 | 131243 | None | V-5P143I12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 2394.99 | 2394.99 | 20.0 | False | None | None | False | None | False | 47899.8 | 0 | 3611225 | 131243 | None | V-5P155I13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 681.45 | 681.45 | 150.0 | False | None | None | False | None | False | 102217.5 | 0 | 3611226 | 131243 | None | V-5P143I12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3611227 | 131243 | None | V-5P154I12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3611228 | 131243 | None | 18-19 SR13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3611229 | 131243 | None | V-5P154I13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.
5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 39817.74 | 39817.74 | 1.0 | False | None | None | False | None | False | 39817.74 | 0 | 3611230 | 131243 | None | V-5P155I13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3611231 | 131243 | None | V-5P155I13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3611232 | 131243 | None | V-5P155I13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3611233 | 131243 | None | V-5P156I13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3611234 | 131243 | None | V-5P156I13.33 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 1672.65 | 1672.65 | 1.0 | False | None | None | False | None | False | 1672.65 | 0 | 3611235 | 131243 | None | 2.6.2 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 208.15 | 208.15 | 165.0 | False | None | None | False | None | False | 34344.75 | 0 | 3611236 | 131243 | None | V-5P20I5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete
16 SWG
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3611237 | 131243 | None | V-5P21I5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.
600mmx600mmx170mm.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3611238 | 131243 | None | 5.6.6 V-6 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 404.08 | 404.08 | 1.0 | False | None | None | False | None | False | 404.08 | 0 | 3611239 | 131243 | None | 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 514.19 | 514.19 | 1.0 | False | None | None | False | None | False | 514.19 | 0 | 3611240 | 131243 | None | 13.18.1 | Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 344.44 | 344.44 | 1.0 | False | None | None | False | None | False | 344.44 | 0 | 3611241 | 131243 | None | 5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kvar | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 | 3611242 | 131243 | None | 1.23 | Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per
specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 3323.0 | 3323.0 | 164.36 | False | None | None | False | None | False | 546168.28 | 0 | 3611243 | 131243 | None | V-2 13.50.5 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work
40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 376.66 | 376.66 | 50.0 | False | None | None | False | None | False | 18833.0 | 0 | 3611244 | 131243 | None | V-2 13.50.6 | Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 478.25 | 478.25 | 20.0 | False | None | None | False | None | False | 9565.0 | 0 | 3611245 | 131243 | None | V-2 13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 358.07 | 358.07 | 185.0 | False | None | None | False | None | False | 66242.95 | 0 | 3611246 | 131243 | None | V-2 13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 477.02 | 477.02 | 120.0 | False | None | None | False | None | False | 57242.4 | 0 | 3611247 | 131243 | None | V-2 IT.NO 13.47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 244.08 | 244.08 | 35.0 | False | None | None | False | None | False | 8542.8 | 0 | 3611248 | 131243 | None | V-2 IT.NO 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 360.55 | 360.55 | 50.0 | False | None | None | False | None | False | 18027.5 | 0 | 3611249 | 131243 | None | V-2 P.NO 128 IT.NO 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 302.32 | 302.32 | 55.0 | False | None | None | False | None | False | 16627.6 | 0 | 3611250 | 131243 | None | V-2 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed
to wooden cleats with C.P. brass screws and washers complete."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1511.58 | 1511.58 | 21.0 | False | None | None | False | None | False | 31743.18 | 0 | 3611251 | 131243 | None | V-2 P.NO 127 IT.NO 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6891.32 | 6891.32 | 4.0 | False | None | None | False | None | False | 27565.28 | 0 | 3611252 | 131243 | None | V-2 P.NO 130 IT.NO 14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 614.54 | 614.54 | 4.0 | False | None | None | False | None | False | 2458.16 | 0 | 3611253 | 131243 | None | V-2 P.NO 123 IT.NO 14.38 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of
the same materials with snap fittings of approved quality and colour,
weighing not less than 105 g"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 179.66 | 179.66 | 4.0 | False | None | None | False | None | False | 718.64 | 0 | 3611254 | 131243 | None | V-2 P.NO 178 IT.NO 14.3.1 | Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush
bend, overflow arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete, including
painting of fittings and brackets, cutting and making good the walls and
floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 7405.5 | 7405.5 | 9.0 | False | None | None | False | None | False | 66649.5 | 0 | 3611255 | 131243 | None | V-2 P.NO 124 IT.NO14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6051.28 | 6051.28 | 10.0 | False | None | None | False | None | False | 60512.8 | 0 | 3611256 | 131243 | None | V-2 P.NO 126 IT.NO 14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6296.6 | 6296.6 | 2.0 | False | None | None | False | None | False | 12593.2 | 0 | 3611257 | 131243 | None | V-2 P.NO 126 IT.NO 14.10.1.1 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per
IS:13983 with C.I. brackets and stainless steel plug 40 mm, including
painting of fittings and brackets, cutting and making good the walls
wherever required : (510x1040 mm bowl depth 250 mm)"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6960.7 | 6960.7 | 4.0 | False | None | None | False | None | False | 27842.8 | 0 | 3611258 | 131243 | None | V-2 13.15 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 898.28 | 898.28 | 12.0 | False | None | None | False | None | False | 10779.36 | 0 | 3611259 | 131243 | None | V-2 P.NO 124 IT.NO 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3818.6 | 3818.6 | 13.0 | False | None | None | False | None | False | 49641.8 | 0 | 3611260 | 131243 | None | V-2 P.NO 120 IT.NO 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 382.85 | 382.85 | 90.0 | False | None | None | False | None | False | 34456.5 | 0 | 3611261 | 131243 | None | V-2 P.NO 120 IT.NO 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 469.58 | 469.58 | 70.0 | False | None | None | False | None | False | 32870.6 | 0 | 3611262 | 131243 | None | V-2 p.NO 120 IT.NO 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
25 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 70.0 | False | None | None | False | None | False | 41370.0 | 0 | 3611263 | 131243 | None | V-2 P.NO 120 IT.NO 13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
32 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 690.12 | 690.12 | 30.0 | False | None | None | False | None | False | 20703.6 | 0 | 3611264 | 131243 | None | V-2 P.NO 120 IT.NO 13.31.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
40 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 664.1 | 664.1 | 20.0 | False | None | None | False | None | False | 13282.0 | 0 | 3611265 | 131243 | None | V-2 P.NO 120IT.NO 13.31.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
50 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 967.66 | 967.66 | 20.0 | False | None | None | False | None | False | 19353.2 | 0 | 3611266 | 131243 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
20mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 268.86 | 268.86 | 50.0 | False | None | None | False | None | False | 13443.0 | 0 | 3611267 | 131243 | None | V-2 P.NO 120 IT.NO 13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
25mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 366.74 | 366.74 | 50.0 | False | None | None | False | None | False | 18337.0 | 0 | 3611268 | 131243 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
40mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 215.0 | False | None | None | False | None | False | 127065.0 | 0 | 3611269 | 131243 | None | V-2 P.NO 120 IT.NO 13.33.7 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
65mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 1734.6 | 1734.6 | 25.0 | False | None | None | False | None | False | 43365.0 | 0 | 3611270 | 131243 | None | V-2 P.NO 120 IT.NO 13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
50mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 893.32 | 893.32 | 40.0 | False | None | None | False | None | False | 35732.8 | 0 | 3611271 | 131243 | None | V2 13.5.2 | Providing and fixing ball valve (brass) of approved quality, High or low
pressure, with plastic floats complete :"
25 mm nominal bore
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 411.35 | 411.35 | 12.0 | False | None | None | False | None | False | 4936.2 | 0 | 3611272 | 131243 | None | V2-13.4 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 32 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 740.92 | 740.92 | 7.0 | False | None | None | False | None | False | 5186.44 | 0 | 3611273 | 131243 | None | V-2 13.4.3 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 40 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 869.78 | 869.78 | 9.0 | False | None | None | False | None | False | 7828.02 | 0 | 3611274 | 131243 | None | v2-13.4.4 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 50 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1059.35 | 1059.35 | 2.0 | False | None | None | False | None | False | 2118.7 | 0 | 3611275 | 131243 | None | V-2,A-13, IT.NO 13.2.1 | Brass bib-cock 15 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 354.35 | 354.35 | 19.0 | False | None | None | False | None | False | 6732.65 | 0 | 3611276 | 131243 | None | V-2 IT.NO 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Ltr | 11.15 | 11.15 | 3000.0 | False | None | None | False | None | False | 33450.0 | 0 | 3611277 | 131243 | None | V2 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 182.13 | 182.13 | 125.0 | False | None | None | False | None | False | 22766.25 | 0 | 3611278 | 131243 | None | Market Rate | Providing and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 177.0 | 177.0 | 55.0 | False | None | None | False | None | False | 9735.0 | 0 | 3611279 | 131243 | None | Market Rate | Air Vent Cowel
75mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 413.0 | 413.0 | 12.0 | False | None | None | False | None | False | 4956.0 | 0 | 3611280 | 131243 | None | Market Rate | Air Vent Cowel
110mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 590.0 | 590.0 | 12.0 | False | None | None | False | None | False | 7080.0 | 0 | 3611281 | 131243 | None | Market Rate | Supplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6844.0 | 6844.0 | 9.0 | False | None | None | False | None | False | 61596.0 | 0 | 3611282 | 131243 | None | Market Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2183.0 | 2183.0 | 9.0 | False | None | None | False | None | False | 19647.0 | 0 | 3611283 | 131243 | None | Market Rate | Supplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 767.0 | 767.0 | 95.0 | False | None | None | False | None | False | 72865.0 | 0 | 3611284 | 131243 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
a) 65mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4130.0 | 4130.0 | 2.0 | False | None | None | False | None | False | 8260.0 | 0 | 3611285 | 131243 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
b) 50mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3304.0 | 3304.0 | 4.0 | False | None | None | False | None | False | 13216.0 | 0 | 3611286 | 131243 | None | V2 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Unit | 345.68 | 345.68 | 4.0 | False | None | None | False | None | False | 1382.72 | 0 | 3611287 | 131243 | None | V2 9.29 | Providing and laying flooring and steps fine dressed granite stone slabs
40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with
cement mortar 1:3 over existing cement concrete bed , including cost
of materials, mortar, labour, curing complete as per specifications."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 5335.13 | 5335.13 | 18.0 | False | None | None | False | None | False | 96032.34 | 0 | 3611288 | 131243 | None | V2 10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded
and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti
tions by cutting a chase of appropriate width with chase cutter and embed
ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3455.57 | 3455.57 | 10.0 | False | None | None | False | None | False | 34555.7 | 0 | 3611289 | 131243 | None | V2 13.28 | Providing and fixing PTMT extension nipple for water tank pipe, fittings
of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 79.3 | 79.3 | 70.0 | False | None | None | False | None | False | 5551.0 | 0 | 3611290 | 131243 | None | 14.36.1 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of
approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g
"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 111.51 | 111.51 | 23.0 | False | None | None | False | None | False | 2564.73 | 0 | 3611291 | 131243 | None | 14.37.1 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective
length of tail pipe 260 mm from the centre of the waste coupling, 77 mm
breadth with 25 mm minimum water seal, weighing not less than 260 g"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Unit | 379.13 | 379.13 | 23.0 | False | None | None | False | None | False | 8719.99 | 0 | 3611292 | 131243 | None | 13.8.1.1 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 102.84 | 102.84 | 23.0 | False | None | None | False | None | False | 2365.32 | 0 | 3611293 | 131243 | None | 14.22.A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1003.59 | 1003.59 | 23.0 | False | None | None | False | None | False | 23082.57 | 0 | 3611294 | 131243 | None | 13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 768.18 | 768.18 | 53.0 | False | None | None | False | None | False | 40713.54 | 0 | 3611295 | 131243 | None | V2 14.63A | Providing and fixing Single lever sink mixer with swivel spout top
outlet wall mountable made of Stainless steel with all concealed fitting
arrangements & all necessary accesories complete - Class Economy "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4667.31 | 4667.31 | 4.0 | False | None | None | False | None | False | 18669.24 | 0 | 3611296 | 131243 | None | 14.4.1 | Providing and fixing white vitreous china flat back or wall corner type
lipped front urinal basin of 430x260x350 mm and 340x410x265 mm
sizes respectively with automatic flushing cistern with standard flush
pipe and C.P. brass spreaders with brass unions and G.I clamps complete,
including painting of fittings and brackets, cutting and making good the
walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 5518.51 | 5518.51 | 4.0 | False | None | None | False | None | False | 22074.04 | 0 | 3611297 | 131243 | None | ELE 7.3 | Supplying, installation, testing and commissioning of solar hot water
heater comprising of solar Flat Plate Collector (FPC) of size
2120x1040x100mm and stainless steel hot water storage tank with
stainless steel heat exchanger absorber made of copper sheet and
copper tube of following capacity aluminium box collector with
appropriate capacity electrical back up arrangement excluding inlet
and out let pipes. SS Model with 100mm thick of 48Kg/M3 density
Rock wool insulation with 22SWG Aluminium cladding."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 39372.94 | 39372.94 | 3.0 | False | None | None | False | None | False | 118118.82 | 0 | 3611298 | 131243 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-110mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 944.0 | 944.0 | 10.0 | False | None | None | False | None | False | 9440.0 | 0 | 3611299 | 131243 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-75mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 767.0 | 767.0 | 2.0 | False | None | None | False | None | False | 1534.0 | 0 | 3611300 | 131243 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-160MM dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1298.0 | 1298.0 | 1.0 | False | None | None | False | None | False | 1298.0 | 0 | 3611301 | 131243 | None | V-1,P.NO 6,IT.NO 1.4.1 | Earth work excavation by manual means for drains,canals, waste weir,
draft, approach channels, key trenches, foundation of bridges and
such simillar works in all kinds of soils , as per drawing and technical
specifications, including setting out, shoring, strutting, barricading,
caution lights, removal of stumps and other deleterious matter,
excavated surface leveled and sides neatly dressed disposing off the
excavated stuff or sorting & stacking the selected stuff for reuse in a
radius of 50 m and lift upto 1.5 m including cost of labour, tools & other
appurtenaces required to complete the work."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 299.84 | 299.84 | 224.0 | False | None | None | False | None | False | 67164.16 | 0 | 3611302 | 131243 | None | V-1 P.NO 7 IT.NO 1.11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 536.49 | 536.49 | 224.0 | False | None | None | False | None | False | 120173.76 | 0 | 3611303 | 131243 | None | V-5 P.NO 134 IT.NO 10.3 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013
with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of
elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing
the pipes alround to a depth of not less than 15 cms. with soft gravel
or selected earth available from the excavation etc. complete and giving
necessary hydraulic test to the required pressure as per ISS (contractor
will make his own arrangements for procuring water for testing) etc.
complete. for:"
Pipes of SN8 Self Fit - 160mm dia.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 764.46 | 764.46 | 300.0 | False | None | None | False | None | False | 229338.0 | 0 | 3611304 | 131243 | None | V-5 P.NO 134 IT.NO 10.2.4 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ).
- do - 160 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 713.66 | 713.66 | 70.0 | False | None | None | False | None | False | 49956.2 | 0 | 3611305 | 131243 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6757.51 | 6757.51 | 45.0 | False | None | None | False | None | False | 304087.95 | 0 | 3611306 | 131243 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6757.51 | 6757.51 | 15.0 | False | None | None | False | None | False | 101362.65 | 0 | 3611307 | 131243 | None | 13.39 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete
with C.I. grating brick masonry chamber 150 x 100 mm size P type With
Non Modular common burnt clay bricks of designation 3.5 & with water
tight C.I. cover with frame of 300 x300 mm size (inside) the weight of
cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as
per standard design:"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3197.86 | 3197.86 | 25.0 | False | None | None | False | None | False | 79946.5 | 0 | 3611308 | 131243 | None | 16.18 | Construction of RCC Machinehole chambers of 1:1.5:3 proportion
or approved type Cast-insitu / Pre-cast RCC Machinehole chambers,
constructed using form vibrators of standard type, with barricading,
danger lighting and using of sight rails and boning rods wherever
necessary, shoring and strutting wherever required using Ordinary
Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down
graded jelly, well graded sand and steel of approved quality, 200 mm
thick top concrete slab, having wall thickness and raft thickness as in
approved drawings and with an offset in raft alround the chamber as
in approved drawing, benching concrete with 1:6 slope towards the
central drain finished smooth, including fixing and grouting of pipes,
including conveying to work spot supply and fixing SFRC Machinehole
cover and frame (Heavy duty) conforming to IS:12592 with latest
amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3
mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia.
Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as
detailed in Technical specifications, including stone grit beding wherever
required, watering, curing, engraving Machinehole number with flow
direction on the inner cylindrical surface etc., complete including
cost of reinforcement steel and fabrication charges and also cost and
conveyance of all materials, labour with all lead and lifts. The Pre-cast
RCC Machinehole are for various diamters and depths as stated below
and as per detailed drawings, specifications and direction of the Engineer.
For 1.2m dia Machinehole:"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 97246.63 | 97246.63 | 1.0 | False | None | None | False | None | False | 97246.63 | 0 | 3611309 | 131243 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
External & Shafts & Terrace
40mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 80.0 | False | None | None | False | None | False | 47280.0 | 0 | 3611310 | 131243 | None | 13.23 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g)
T.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1665.22 | 1665.22 | 5.0 | False | None | None | False | None | False | 8326.1 | 0 | 3611311 | 131243 | None | 13.40.1 V-5 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 19340.79 | 19340.79 | 2.0 | False | None | None | False | None | False | 38681.58 | 0 | 3611312 | 131243 | None | 13.32 V-5 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and
equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 8053.5 | 8053.5 | 2.0 | False | None | None | False | None | False | 16107.0 | 0 | 3611313 | 131243 | None | PWD ELE SR V-6 IT.NO 2.2.1 | WIRES & CABLES
Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Short point up to 3Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 333.29 | 333.29 | 25.0 | False | None | None | False | None | False | 8332.25 | 0 | 3611314 | 131243 | None | PWD ELE SR V-10 IT.NO 2.2.2 | Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Pack | 469.58 | 469.58 | 36.0 | False | None | None | False | None | False | 16904.88 | 0 | 3611315 | 131243 | None | PWD ELE SR V-11 IT.NO 2.2.3 | Point wiring using Copper wire without switch.
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Long point above 6Mtr up to 10Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 687.65 | 687.65 | 63.0 | False | None | None | False | None | False | 43321.95 | 0 | 3611316 | 131243 | None | PWD ELE SR V-12 IT.NO 2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 838.8 | 838.8 | 8.0 | False | None | None | False | None | False | 6710.4 | 0 | 3611317 | 131243 | None | PWD ELE SR V-14 IT.NO 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
1-3Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 170.98 | 170.98 | 25.0 | False | None | None | False | None | False | 4274.5 | 0 | 3611318 | 131243 | None | PWD ELE SR V-15 IT.NO 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
4-5Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 197.0 | 197.0 | 32.0 | False | None | None | False | None | False | 6304.0 | 0 | 3611319 | 131243 | None | PWD ELE SR V-16 IT.NO 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
6Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 219.3 | 219.3 | 16.0 | False | None | None | False | None | False | 3508.8 | 0 | 3611320 | 131243 | None | PWD ELE SR V-17 IT.NO 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
8 Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 272.58 | 272.58 | 7.0 | False | None | None | False | None | False | 1908.06 | 0 | 3611321 | 131243 | None | PWD ELE SR V-18 IT.NO 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
10-12Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 323.38 | 323.38 | 20.0 | False | None | None | False | None | False | 6467.6 | 0 | 3611322 | 131243 | None | PWD ELE SR V-20 IT.NO 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
1 to 3 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 199.48 | 199.48 | 32.0 | False | None | None | False | None | False | 6383.36 | 0 | 3611323 | 131243 | None | PWD ELE SR V-21 IT.NO 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
4 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 216.83 | 216.83 | 16.0 | False | None | None | False | None | False | 3469.28 | 0 | 3611324 | 131243 | None | PWD ELE SR V-22 IT.NO 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
6 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 289.93 | 289.93 | 7.0 | False | None | None | False | None | False | 2029.51 | 0 | 3611325 | 131243 | None | PWD ELE SR V-23 IT.NO 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
8 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 351.88 | 351.88 | 21.0 | False | None | None | False | None | False | 7389.48 | 0 | 3611326 | 131243 | None | PWD ELE SR V-24 IT.NO 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
10-12 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 426.22 | 426.22 | 31.0 | False | None | None | False | None | False | 13212.82 | 0 | 3611327 | 131243 | None | PWD ELE SR V-26 IT.NO 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps one way Switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 126.38 | 126.38 | 217.0 | False | None | None | False | None | False | 27424.46 | 0 | 3611328 | 131243 | None | PWD ELE SR V-6 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps Two way Switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 205.67 | 205.67 | 2.0 | False | None | None | False | None | False | 411.34 | 0 | 3611329 | 131243 | None | PWD ELE SR V-6,IT.NO 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps 3way socket
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 211.87 | 211.87 | 81.0 | False | None | None | False | None | False | 17161.47 | 0 | 3611330 | 131243 | None | PWD ELE SR V-6,IT.NO 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Stepped Fan Regulator.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 442.32 | 442.32 | 24.0 | False | None | None | False | None | False | 10615.68 | 0 | 3611331 | 131243 | None | PWD ELE SR V-6,IT.NO 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
16Amps one way switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 223.02 | 223.02 | 10.0 | False | None | None | False | None | False | 2230.2 | 0 | 3611332 | 131243 | None | PWD ELE SR V-6, IT.NO 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
32Amps DP switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 403.91 | 403.91 | 15.0 | False | None | None | False | None | False | 6058.65 | 0 | 3611333 | 131243 | None | PWD ELE SR V-6,IT.NO 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6/16Amps universal socket
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 292.4 | 292.4 | 25.0 | False | None | None | False | None | False | 7310.0 | 0 | 3611334 | 131243 | None | PWD ELE SR V-6,IT.NO 1.13 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Supplyin and Fixing Metal Fan Box with Round Hook.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 144.96 | 144.96 | 24.0 | False | None | None | False | None | False | 3479.04 | 0 | 3611335 | 131243 | None | PWD ELE SR V-6,IT.NO-1.2.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
19/20mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 81.77 | 81.77 | 890.0 | False | None | None | False | None | False | 72775.3 | 0 | 3611336 | 131243 | None | PWD ELE SR V-6,IT.NO 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
25mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 96.64 | 96.64 | 1030.0 | False | None | None | False | None | False | 99539.2 | 0 | 3611337 | 131243 | None | PWD ELE SR V-6, IT.NO .2.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
32mm dia 2.5mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 127.62 | 127.62 | 250.0 | False | None | None | False | None | False | 31905.0 | 0 | 3611338 | 131243 | None | PWD ELE SR V-6,IT.NO1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
19/20mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 84.25 | 84.25 | 445.0 | False | None | None | False | None | False | 37491.25 | 0 | 3611339 | 131243 | None | PWD ELE SR V-6,IT.NO-1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 97.88 | 97.88 | 515.0 | False | None | None | False | None | False | 50408.2 | 0 | 3611340 | 131243 | None | PWD ELE SR V-6,IT.NO-1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
32mm dia 2.5mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 122.66 | 122.66 | 150.0 | False | None | None | False | None | False | 18399.0 | 0 | 3611341 | 131243 | None | PWD ELE SR V-6,IT.NO 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 32.21 | 32.21 | 470.0 | False | None | None | False | None | False | 15138.7 | 0 | 3611342 | 131243 | None | PWD ELE SR V-6,IT.NO 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 52.04 | 52.04 | 1530.0 | False | None | None | False | None | False | 79621.2 | 0 | 3611343 | 131243 | None | PWD ELE SR V-6,IT.NO 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
4 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 78.06 | 78.06 | 740.0 | False | None | None | False | None | False | 57764.4 | 0 | 3611344 | 131243 | None | PWD ELE SR V-6,IT.NO 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
6 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 113.99 | 113.99 | 580.0 | False | None | None | False | None | False | 66114.2 | 0 | 3611345 | 131243 | None | PWD ELE SR V-6,IT.NO 5.19.11 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure
III - Double Door
4 Way TP & N
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 5003.08 | 5003.08 | 2.0 | False | None | None | False | None | False | 10006.16 | 0 | 3611346 | 131243 | None | PWD ELE SR V-6,IT.NO 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
6-32Amps SP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 514.19 | 514.19 | 62.0 | False | None | None | False | None | False | 31879.78 | 0 | 3611347 | 131243 | None | PWD ELE SR V-6 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
40Amps TPN
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3771.52 | 3771.52 | 2.0 | False | None | None | False | None | False | 7543.04 | 0 | 3611348 | 131243 | None | PWD ELE SR V-6,IT.NO 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board
16-25 Amps 2 pole
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 5299.2 | 5299.2 | 2.0 | False | None | None | False | None | False | 10598.4 | 0 | 3611349 | 131243 | None | PWD ELE SR V-6,IT.NO 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only)
32mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 480.73 | 480.73 | 10.0 | False | None | None | False | None | False | 4807.3 | 0 | 3611350 | 131243 | None | PWD ELE SR V-6,IT.NO 6.17.8 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.
35 sqmm Long Barrel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 39.65 | 39.65 | 16.0 | False | None | None | False | None | False | 634.4 | 0 | 3611351 | 131243 | None | V-6 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4348.89 | 4348.89 | 7.0 | False | None | None | False | None | False | 30442.23 | 0 | 3611352 | 131243 | None | V-6 12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x3mm GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 101.6 | 101.6 | 100.0 | False | None | None | False | None | False | 10160.0 | 0 | 3611353 | 131243 | None | 12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
600X600X3 GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1084.13 | 1084.13 | 6.0 | False | None | None | False | None | False | 6504.78 | 0 | 3611354 | 131243 | None | 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1096.52 | 1096.52 | 19.0 | False | None | None | False | None | False | 20833.88 | 0 | 3611355 | 131243 | None | 11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1640.44 | 1640.44 | 5.0 | False | None | None | False | None | False | 8202.2 | 0 | 3611356 | 131243 | None | 11.3.2 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 854.91 | 854.91 | 51.0 | False | None | None | False | None | False | 43600.41 | 0 | 3611357 | 131243 | None | 11.11.3 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 184.61 | 184.61 | 15.0 | False | None | None | False | None | False | 2769.15 | 0 | 3611358 | 131243 | None | PWD ELE SR V-6,IT.NO 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1848.59 | 1848.59 | 13.0 | False | None | None | False | None | False | 24031.67 | 0 | 3611359 | 131243 | None | PWD ELE SR V-6,IT.NO 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3316.8 | 3316.8 | 24.0 | False | None | None | False | None | False | 79603.2 | 0 | 3611360 | 131243 | None | PWD ELE SR V-6,IT.NO 13.11 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.
On wall / ceiling / Rafter / Girders
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 390.29 | 390.29 | 24.0 | False | None | None | False | None | False | 9366.96 | 0 | 3611361 | 131243 | None | PWD ELE SR V-6,IT.NO 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 151.16 | 151.16 | 83.0 | False | None | None | False | None | False | 12546.28 | 0 | 3611362 | 131243 | None | PWD ELE SR V-6,IT.NO 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 875.97 | 875.97 | 13.0 | False | None | None | False | None | False | 11387.61 | 0 | 3611363 | 131243 | None | PWD ELE SR V-6,IT.NO 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 200.72 | 200.72 | 3.0 | False | None | None | False | None | False | 602.16 | 0 | 3611364 | 131243 | None | PWD ELE SR V-6,IT.NO 5.42.1 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete
16SWG
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 86000.0 | False | None | None | False | None | False | 45580.0 | 0 | 3611365 | 131243 | None | PWD ELE SR V-6,IT.NO 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 4255.97 | 4255.97 | 5.0 | False | None | None | False | None | False | 21279.85 | 0 | 3611366 | 131243 | None | PWD ELE SR V-6,IT.NO 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
40x40x6mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 377.9 | 377.9 | 10.0 | False | None | None | False | None | False | 3779.0 | 0 | 3611367 | 131243 | None | PWD ELE SR V-6,IT.NO 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
50x100x50x6mm C channel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 936.68 | 936.68 | 10.0 | False | None | None | False | None | False | 9366.8 | 0 | 3611368 | 131243 | None | PWD ELE SR V-6,IT.NO 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs)
100Amps 25kA
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 10515.39 | 10515.39 | 1.0 | False | None | None | False | None | False | 10515.39 | 0 | 3611369 | 131243 | None | PWD ELE SR V-6,iT.NO 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
50-63Amps DP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3826.03 | 3826.03 | 10.0 | False | None | None | False | None | False | 38260.3 | 0 | 3611370 | 131243 | None | PWD ELE SR V-6,IT.NO 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 11541.29 | 11541.29 | 1.0 | False | None | None | False | None | False | 11541.29 | 0 | 3611371 | 131243 | None | PWD ELE SR V-6,IT.NO 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3611372 | 131243 | None | PWD ELE SR V-6,IT.NO 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 696.32 | 696.32 | 3.0 | False | None | None | False | None | False | 2088.96 | 0 | 3611373 | 131243 | None | PWD ELE SR V-6,IT.NO5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kvar | 594.72 | 594.72 | 15.0 | False | None | None | False | None | False | 8920.8 | 0 | 3611374 | 131243 | None | 5.19.9 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2885.63 | 2885.63 | 2.0 | False | None | None | False | None | False | 5771.26 | 0 | 3611375 | 131243 | None | 5.19.12 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6120.66 | 6120.66 | 1.0 | False | None | None | False | None | False | 6120.66 | 0 | 3611376 | 131243 | None | 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3826.03 | 3826.03 | 1.0 | False | None | None | False | None | False | 3826.03 | 0 | 3611377 | 131243 | None | 5.20.8 | Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6377.13 | 6377.13 | 3.0 | False | None | None | False | None | False | 19131.39 | 0 | 3611378 | 131243 | None | 32.05 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 109549.9 | 109549.9 | 0.1 | False | None | None | False | None | False | 10954.99 | 0 | 3611379 | 131243 | None | 32.09 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 190882.82 | 190882.82 | 0.05 | False | None | None | False | None | False | 9544.141 | 0 | 3611380 | 131243 | None | 32.13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 393892.97 | 393892.97 | 0.1 | False | None | None | False | None | False | 39389.297 | 0 | 3611381 | 131243 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 25877.75 | 25877.75 | 0.05 | False | None | None | False | None | False | 1293.8875 | 0 | 3611382 | 131243 | None | 31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 38581.22 | 38581.22 | 0.2 | False | None | None | False | None | False | 7716.244 | 0 | 3611383 | 131243 | None | 6.17.6 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 15.41 | 15.41 | 20.0 | False | None | None | False | None | False | 308.2 | 0 | 3611384 | 131243 | None | 16.17.10 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 148.68 | 148.68 | 16.0 | False | None | None | False | None | False | 2378.88 | 0 | 3611385 | 131243 | None | 11.11.5 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 333.29 | 333.29 | 9.0 | False | None | None | False | None | False | 2999.61 | 0 | 3611386 | 131243 | None | 11.6.3 | Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 5641.17 | 5641.17 | 8.0 | False | None | None | False | None | False | 45129.36 | 0 | 3611387 | 131243 | None | 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4985.74 | 4985.74 | 2.0 | False | None | None | False | None | False | 9971.48 | 0 | 3611388 | 131243 | None | 13.4.1 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1810.18 | 1810.18 | 3.0 | False | None | None | False | None | False | 5430.54 | 0 | 3611389 | 131243 | None | 5.14.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 2738.19 | 2738.19 | 2.0 | False | None | None | False | None | False | 5476.38 | 0 | 3611390 | 131243 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 169.74 | 169.74 | 24.0 | False | None | None | False | None | False | 4073.76 | 0 | 3611391 | 131243 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 395.24 | 395.24 | 31.0 | False | None | None | False | None | False | 12252.44 | 0 | 3611392 | 131243 | None | 2.2.5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 1225.37 | 1225.37 | 4.0 | False | None | None | False | None | False | 4901.48 | 0 | 3611393 | 131243 | None | 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 144.96 | 144.96 | 6.0 | False | None | None | False | None | False | 869.76 | 0 | 3611394 | 131243 | None | 12.46 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 78.06 | 78.06 | 21.0 | False | None | None | False | None | False | 1639.26 | 0 | 3611395 | 131243 | None | 3.6.11 | TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 193.28 | 193.28 | 2.0 | False | None | None | False | None | False | 386.56 | 0 | 3611396 | 131243 | None | 12.2.1 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 304.79 | 304.79 | 1.0 | False | None | None | False | None | False | 304.79 | 0 | 3611397 | 131243 | None | 32.02 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 98168.45 | 98168.45 | 0.1 | False | None | None | False | None | False | 9816.845 | 0 | 3611398 | 131243 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 25877.75 | 25877.75 | 0.1 | False | None | None | False | None | False | 2587.775 | 0 | 3611399 | 131243 | None | pwd sr | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 15.41 | 15.41 | 15.0 | False | None | None | False | None | False | 231.15 | 0 | 3611400 | 131243 | None | 11..11.7 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 527.81 | 527.81 | 3.0 | False | None | None | False | None | False | 1583.43 | 0 | 3611401 | 131243 | None | 12.27 | Supplying & Fixing of Special Type pigmy and candle lamp.
Operating voltage range from 180V to 265V, 50Hz AC power Supply"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 64.43 | 64.43 | 2.0 | False | None | None | False | None | False | 128.86 | 0 | 3611402 | 131243 | None | 11.8.1 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3004.58 | 3004.58 | 1.0 | False | None | None | False | None | False | 3004.58 | 0 | 3611403 | 131243 | None | 5.7.2 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 298.6 | 298.6 | 1.0 | False | None | None | False | None | False | 298.6 | 0 | 3611404 | 131243 | None | 5.30 | Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1709.82 | 1709.82 | 1.0 | False | None | None | False | None | False | 1709.82 | 0 | 3611405 | 131243 | None | 7.1.3 | Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 12689.84 | 12689.84 | 1.0 | False | None | None | False | None | False | 12689.84 | 0 | 3611406 | 131243 | None | PWD SR 2023-24 Volume 6 It No-9.3.3 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 84726.54 | 84726.54 | 1.0 | False | None | None | False | None | False | 84726.54 | 0 | 3611407 | 131243 | None | PWD SR 2023-24 Volume 6 It No-9.5.9 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 19693.91 | 19693.91 | 4.0 | False | None | None | False | None | False | 78775.64 | 0 | 3611408 | 131243 | None | A.R | Item Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 300000.0 | 300000.0 | 1.0 | False | None | None | False | None | False | 300000.0 | 0 | 3611409 | 131243 | None | LQR | IP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 23836.0 | 23836.0 | 4.0 | False | None | None | False | None | False | 95344.0 | 0 | 3611410 | 131243 | None | LQR | IP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 25606.0 | 25606.0 | 2.0 | False | None | None | False | None | False | 51212.0 | 0 | 3611411 | 131243 | None | LQR | Supplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3611412 | 131243 | None | LQR | Supply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 17110.0 | 17110.0 | 2.0 | False | None | None | False | None | False | 34220.0 | 0 | 3611413 | 131243 | None | LQR | Supply and Installation of I/Os
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 147.5 | 147.5 | 12.0 | False | None | None | False | None | False | 1770.0 | 0 | 3611414 | 131243 | None | LQR | Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 265.5 | 265.5 | 12.0 | False | None | None | False | None | False | 3186.0 | 0 | 3611415 | 131243 | None | LQR | Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 336.3 | 336.3 | 6.0 | False | None | None | False | None | False | 2017.8 | 0 | 3611416 | 131243 | None | LQR | Supply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3611417 | 131243 | None | V-6 8.1 | Supplying and drawing UTP-CAT 6E LAN cable
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 47.08 | 47.08 | 600.0 | False | None | None | False | None | False | 28248.0 | 0 | 3611418 | 131243 | None | 1.2.2 | Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 96.64 | 96.64 | 500.0 | False | None | None | False | None | False | 48320.0 | 0 | 3611419 | 131243 | None | 8.12.3 | Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3778.95 | 3778.95 | 1.0 | False | None | None | False | None | False | 3778.95 | 0 | 3611420 | 131243 | None | 8.4.1 v-6 | Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 6061.19 | 6061.19 | 1.0 | False | None | None | False | None | False | 6061.19 | 0 | 3611421 | 131243 | None | 1.01 | Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 8767.16 | 8767.16 | 8.0 | False | None | None | False | None | False | 70137.28 | 0 | 3611422 | 131243 | None | 2.02 | Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 1379.01 | 1379.01 | 8.0 | False | None | None | False | None | False | 11032.08 | 0 | 3611423 | 131243 | None | 6.05 | Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 107.79 | 107.79 | 6.0 | False | None | None | False | None | False | 646.74 | 0 | 3611424 | 131243 | None | 13.12 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 59.47 | 59.47 | 6.0 | False | None | None | False | None | False | 356.82 | 0 | 3611425 | 131243 | None | 2.16 | Supply of Spiral Earth Electrode
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 296.12 | 296.12 | 11.0 | False | None | None | False | None | False | 3257.32 | 0 | 3611426 | 131243 | None | 2.16 | Erection of Spiral Earth Electrode
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 115.23 | 115.23 | 11.0 | False | None | None | False | None | False | 1267.53 | 0 | 3611427 | 131243 | None | 68.17 | Supply and fixing of Caution/Danger Board
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 185.85 | 185.85 | 6.0 | False | None | None | False | None | False | 1115.1 | 0 | 3611428 | 131243 | None | 4.02 | Supply of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 110.27 | 110.27 | 8.0 | False | None | None | False | None | False | 882.16 | 0 | 3611429 | 131243 | None | 5.09 | Erection of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 52.04 | 52.04 | 8.0 | False | None | None | False | None | False | 416.32 | 0 | 3611430 | 131243 | None | 24.05 | Supply and fixing of 11 kV, 400 Amps Double Break GOS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 26341.14 | 26341.14 | 1.0 | False | None | None | False | None | False | 26341.14 | 0 | 3611431 | 131243 | None | 24.07 | Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 7521.97 | 7521.97 | 1.0 | False | None | None | False | None | False | 7521.97 | 0 | 3611432 | 131243 | None | 25.01 | Supply of DOLO Cut Out
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set of 3 Nos | 7279.13 | 7279.13 | 1.0 | False | None | None | False | None | False | 7279.13 | 0 | 3611433 | 131243 | None | 13.01 | Erection of DOLO Cut Out
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set of 3 Nos | 293.64 | 293.64 | 1.0 | False | None | None | False | None | False | 293.64 | 0 | 3611434 | 131243 | None | 13.07 | Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 210958.34 | 210958.34 | 1.0 | False | None | None | False | None | False | 210958.34 | 0 | 3611435 | 131243 | None | 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 4348.89 | 4348.89 | 8.0 | False | None | None | False | None | False | 34791.12 | 0 | 3611436 | 131243 | None | 12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | MT | 158.59 | 158.59 | 100.0 | False | None | None | False | None | False | 15859.0 | 0 | 3611437 | 131243 | None | 12.58.9 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 2035.68 | 2035.68 | 100.0 | False | None | None | False | None | False | 203568.0 | 0 | 3611438 | 131243 | None | 12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 9194.62 | 9194.62 | 10.0 | False | None | None | False | None | False | 91946.2 | 0 | 3611439 | 131243 | None | 45.07 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 5039.01 | 5039.01 | 4.0 | False | None | None | False | None | False | 20156.04 | 0 | 3611440 | 131243 | None | 45.04 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 3887.98 | 3887.98 | 2.0 | False | None | None | False | None | False | 7775.96 | 0 | 3611441 | 131243 | None | 36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 1102296.17 | 1102296.17 | 0.1 | False | None | None | False | None | False | 110229.617 | 0 | 3611442 | 131243 | None | 38. | Providing chain link fencing 50 mm size of 8 guage properly stretched between
rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be
welded to the Pole and block pipe at top and bottom as required including cost
of all materials, labour, lead and lifts, cutting, bending wherever necessary,
wastage and lapping etc., complete as per the direction of the engineer
incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1222.89 | 1222.89 | 150.0 | False | None | None | False | None | False | 183433.5 | 0 | 3611443 | 131243 | None | 5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 176000.0 | False | None | None | False | None | False | 93280.0 | 0 | 3611444 | 131243 | None | 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 4255.97 | 4255.97 | 6.0 | False | None | None | False | None | False | 25535.82 | 0 | 3611445 | 131243 | None | 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 377.9 | 377.9 | 12.0 | False | None | None | False | None | False | 4534.8 | 0 | 3611446 | 131243 | None | 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 936.68 | 936.68 | 12.0 | False | None | None | False | None | False | 11240.16 | 0 | 3611447 | 131243 | None | 5.15.15 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 29172.26 | 29172.26 | 1.0 | False | None | None | False | None | False | 29172.26 | 0 | 3611448 | 131243 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3611449 | 131243 | None | 10.1.3 | Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have +
1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating
lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting
battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr
at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 558914.14 | 558914.14 | 1.0 | False | None | None | False | None | False | 558914.14 | 0 | 3611450 | 131243 | None | 10.2.2 | Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the
accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 72742.93 | 72742.93 | 1.0 | False | None | None | False | None | False | 72742.93 | 0 | 3611451 | 131243 | None | A.R | Supply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 3540.0 | 3540.0 | 5.0 | False | None | None | False | None | False | 17700.0 | 0 | 3611452 | 131243 | None | A.R | Supply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 236.0 | 236.0 | 50.0 | False | None | None | False | None | False | 11800.0 | 0 | 3611453 | 131243 | None | 58.02 | LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 98973.8 | 98973.8 | 1.0 | False | None | None | False | None | False | 98973.8 | 0 | 3611454 | 131243 | None | 53.01 | CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 24302.99 | 24302.99 | 1.0 | False | None | None | False | None | False | 24302.99 | 0 | 3611455 | 131243 | None | 10.01 | Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 173.46 | 173.46 | 15.0 | False | None | None | False | None | False | 2601.9 | 0 | 3611456 | 131243 | None | v-6 2.02 | Supply of 11 kV, Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr
Long, 145 Kg WL"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 603.39 | 603.39 | 6.0 | False | None | None | False | None | False | 3620.34 | 0 | 3611457 | 131243 | None | v-6 2.02 | Erection of 11 kV, Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr
Long, 145 Kg WL"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 318.42 | 318.42 | 6.0 | False | None | None | False | None | False | 1910.52 | 0 | 3611458 | 131243 | None | v-6 6.06 | Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP
Rod) "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 254.0 | 254.0 | 18.0 | False | None | None | False | None | False | 4572.0 | 0 | 3611459 | 131243 | None | v-6 6.10 | Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 235.45 | 235.45 | 18.0 | False | None | None | False | None | False | 4238.1 | 0 | 3611460 | 131243 | None | 13.12 v-6 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 59.47 | 59.47 | 18.0 | False | None | None | False | None | False | 1070.46 | 0 | 3611461 | 131243 | None | v-6 6.08 | Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 73.1 | 73.1 | 4.0 | False | None | None | False | None | False | 292.4 | 0 | 3611462 | 131243 | None | 7.02 | Supply of Rabbit ACSR Conductor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 57283.93 | 57283.93 | 1.0 | False | None | None | False | None | False | 57283.93 | 0 | 3611463 | 131243 | None | 6.02 V-6 | Erection of Rabbit ACSR Conductor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 5403.28 | 5403.28 | 1.0 | False | None | None | False | None | False | 5403.28 | 0 |
| 1721828234000 | 0 | None | None | Buildings | NARAYANPUR IN SHORAPUR TALUK OF YADGIR DISTRICT (CIVIL WORKS) | 27725914.4 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3611464 | 131244 | None | CSR:V-3 PAGE NO 9 Itm 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | 100 Sqm | 486.93 | 486.93 | 17.49 | False | None | None | False | None | False | 8516.4057 | 0 | 3611465 | 131244 | None | V-1 page 8 itm 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 117.71 | 117.71 | 768.64 | False | None | None | False | None | False | 90476.6144 | 0 | 3611466 | 131244 | None | V-1page 8 itm 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 126.38 | 126.38 | 809.88 | False | None | None | False | None | False | 102352.6344 | 0 | 3611467 | 131244 | None | V-1page 8 itm 1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 449.76 | 449.76 | 583.66 | False | None | None | False | None | False | 262506.9216 | 0 | 3611468 | 131244 | None | V-3page 3 A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 167.27 | 167.27 | 225.13 | False | None | None | False | None | False | 37657.4951 | 0 | 3611469 | 131244 | None | V-2page5 itm 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 146.2 | 146.2 | 774.16 | False | None | None | False | None | False | 113182.192 | 0 | 3611470 | 131244 | None | V-1pg7 itm1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 329.57 | 329.57 | 305.66 | False | None | None | False | None | False | 100736.3662 | 0 | 3611471 | 131244 | None | V-1page7vitm1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 587.29 | 587.29 | 1082.02 | False | None | None | False | None | False | 635459.5258 | 0 | 3611472 | 131244 | None | V-1page 15 itm2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7420.37 | 7420.37 | 161.37 | False | None | None | False | None | False | 1197425.1069 | 0 | 3611473 | 131244 | None | V-1page15 itm 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR FOOTING ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8478.33 | 8478.33 | 177.95 | False | None | None | False | None | False | 1508718.8235 | 0 | 3611474 | 131244 | None | V-1page16 itm 2.2.3 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatess FOR PEDESTAL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8635.33 | 8635.33 | 13.4 | False | None | None | False | None | False | 115713.422 | 0 | 3611475 | 131244 | None | V-1page15itm 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR COLUMNS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 14413.41 | 14413.41 | 52.43 | False | None | None | False | None | False | 755695.0863 | 0 | 3611476 | 131244 | None | V-3page135itm15.4 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 252.76 | 252.76 | 13.0 | False | None | None | False | None | False | 3285.88 | 0 | 3611477 | 131244 | None | V-2page55 itm 8.16.a | Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1533.88 | 1533.88 | 13.81 | False | None | None | False | None | False | 21182.8828 | 0 | 3611478 | 131244 | None | V-1page18itm2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. - Buildings ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Tonne | 110837.22 | 110837.22 | 50.48 | False | None | None | False | None | False | 5595062.8656 | 0 | 3611479 | 131244 | None | 18-19SR ITM4.21 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No KBS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 38.94 | 38.94 | 145.02 | False | None | None | False | None | False | 5647.0788 | 0 | 3611480 | 131244 | None | DATA RATE | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 86.14 | 86.14 | 145.02 | False | None | None | False | None | False | 12492.0228 | 0 | 3611481 | 131244 | None | V-2PAGE 9 ITM5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7915.97 | 7915.97 | 8.76 | False | None | None | False | None | False | 69343.8972 | 0 | 3611482 | 131244 | None | V-2PAGE 14 ITM 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1623.09 | 1623.09 | 1313.93 | False | None | None | False | None | False | 2132626.6437 | 0 | 3611483 | 131244 | None | V-2page 14 itm 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks
of size 400x100x200mm having block density more than 1800kg/m3
and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005
including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1367.86 | 1367.86 | 171.24 | False | None | None | False | None | False | 234232.3464 | 0 | 3611484 | 131244 | None | V-2 page100 itm 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 122431.79 | 122431.79 | 1.2 | False | None | None | False | None | False | 146918.148 | 0 | 3611485 | 131244 | None | V-2 page 105 itm 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 1258.82 | 1258.82 | 32.0 | False | None | None | False | None | False | 40282.24 | 0 | 3611486 | 131244 | None | 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 681.45 | 681.45 | 64.0 | False | None | None | False | None | False | 43612.8 | 0 | 3611487 | 131244 | None | 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 464.63 | 464.63 | 32.0 | False | None | None | False | None | False | 14868.16 | 0 | 3611488 | 131244 | None | 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 185.85 | 185.85 | 64.0 | False | None | None | False | None | False | 11894.4 | 0 | 3611489 | 131244 | None | 22.15.9 | PProviding and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 86.73 | 86.73 | 128.0 | False | None | None | False | None | False | 11101.44 | 0 | 3611490 | 131244 | None | 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 123.9 | 123.9 | 32.0 | False | None | None | False | None | False | 3964.8 | 0 | 3611491 | 131244 | None | 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 1303.43 | 1303.43 | 32.0 | False | None | None | False | None | False | 41709.76 | 0 | 3611492 | 131244 | None | V-2page69 itm 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 74.34 | 74.34 | 192.0 | False | None | None | False | None | False | 14273.28 | 0 | 3611493 | 131244 | None | 20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 64.43 | 64.43 | 168.45 | False | None | None | False | None | False | 10853.2335 | 0 | 3611494 | 131244 | None | V-2page105 itm 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4115.96 | 4115.96 | 74.84 | False | None | None | False | None | False | 308038.4464 | 0 | 3611495 | 131244 | None | V-2page109 itm 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 8343.43 | 8343.43 | 69.39 | False | None | None | False | None | False | 578950.6077 | 0 | 3611496 | 131244 | None | V-2page109 itm 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 7085.84 | 7085.84 | 6.84 | False | None | None | False | None | False | 48467.1456 | 0 | 3611497 | 131244 | None | V-2page 86itm11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 208.15 | 208.15 | 1600.83 | False | None | None | False | None | False | 333212.7645 | 0 | 3611498 | 131244 | None | V-2page 111itm 12.93.1 | Providing and fixing factory made single extruded WPC (WoodPolymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58- 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/
cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately).Size 62 x 100mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | m | 869.78 | 869.78 | 64.35 | False | None | None | False | None | False | 55970.343 | 0 | 3611499 | 131244 | None | V-2page84 itm 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kgs | 168.5 | 168.5 | 1724.91 | False | None | None | False | None | False | 290647.335 | 0 | 3611500 | 131244 | None | V-2page 41itm 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 386.57 | 386.57 | 1763.82 | False | None | None | False | None | False | 681839.8974 | 0 | 3611501 | 131244 | None | V-2page 43 itm 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 261.43 | 261.43 | 1176.83 | False | None | None | False | None | False | 307658.6669 | 0 | 3611502 | 131244 | None | V-2page50 itm 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 123.9 | 123.9 | 2919.03 | False | None | None | False | None | False | 361667.817 | 0 | 3611503 | 131244 | None | V-2page42itm 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 432.41 | 432.41 | 975.48 | False | None | None | False | None | False | 421807.3068 | 0 | 3611504 | 131244 | None | V-2page41 itm 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 438.61 | 438.61 | 163.05 | False | None | None | False | None | False | 71515.3605 | 0 | 3611505 | 131244 | None | 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 47.08 | 47.08 | 2013.85 | False | None | None | False | None | False | 94812.058 | 0 | 3611506 | 131244 | None | 10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 254.88 | 254.88 | 13.0 | False | None | None | False | None | False | 3313.44 | 0 | 3611507 | 131244 | None | V-2page 54itm 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 64.43 | 64.43 | 628.05 | False | None | None | False | None | False | 40465.2615 | 0 | 3611508 | 131244 | None | V-2page61itm 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.).Size of Tile 600x600 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1455.83 | 1455.83 | 580.89 | False | None | None | False | None | False | 845677.0887 | 0 | 3611509 | 131244 | None | V-2page59 itm9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 991.2 | 991.2 | 71.5 | False | None | None | False | None | False | 70870.8 | 0 | 3611510 | 131244 | None | V-2page63 itm 9.32 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3199.1 | 3199.1 | 34.54 | False | None | None | False | None | False | 110496.914 | 0 | 3611511 | 131244 | None | V-2page 4 itm 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 365.51 | 365.51 | 316.07 | False | None | None | False | None | False | 115526.7457 | 0 | 3611512 | 131244 | None | V-2page 60 itm 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1101.47 | 1101.47 | 59.14 | False | None | None | False | None | False | 65140.9358 | 0 | 3611513 | 131244 | None | V-2page65 itmv9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1795.31 | 1795.31 | 259.57 | False | None | None | False | None | False | 466008.6167 | 0 | 3611514 | 131244 | None | V-2 page85 itm11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 700.04 | 700.04 | 357.82 | False | None | None | False | None | False | 250488.3128 | 0 | 3611515 | 131244 | None | V-2 page 48itm 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 157.35 | 157.35 | 2741.14 | False | None | None | False | None | False | 431318.379 | 0 | 3611516 | 131244 | None | V-2page 46itm8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 193.28 | 193.28 | 759.66 | False | None | None | False | None | False | 146827.0848 | 0 | 3611517 | 131244 | None | V-2page47 itm8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 61.95 | 61.95 | 96.21 | False | None | None | False | None | False | 5960.2095 | 0 | 3611518 | 131244 | None | V-2page48 itm 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 142.49 | 142.49 | 76.23 | False | None | None | False | None | False | 10862.0127 | 0 | 3611519 | 131244 | None | V-2page47itm 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 65.67 | 65.67 | 179.6 | False | None | None | False | None | False | 11794.332 | 0 | 3611520 | 131244 | None | 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 838.8 | 838.8 | 179.6 | False | None | None | False | None | False | 150648.48 | 0 | 3611521 | 131244 | None | V-2page64itm 9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 2044.35 | 2044.35 | 17.32 | False | None | None | False | None | False | 35408.142 | 0 | 3611522 | 131244 | None | V-2page77 itm 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 5548.24 | 5548.24 | 5.25 | False | None | None | False | None | False | 29128.26 | 0 | 3611523 | 131244 | None | 15.12 | Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1443.44 | 1443.44 | 726.5 | False | None | None | False | None | False | 1048659.16 | 0 | 3611524 | 131244 | None | V-2PAGE22 ITM 7.17 | Providing and laying to required line and slope roofing with corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses including cost of materials, labour, complete as per specifications ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 411.35 | 411.35 | 24.74 | False | None | None | False | None | False | 10176.799 | 0 | 3611525 | 131244 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR PLINTH BEAM ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 102.35 | False | None | None | False | None | False | 1301658.642 | 0 | 3611526 | 131244 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC BEAMS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 13565.56 | 13565.56 | 51.01 | False | None | None | False | None | False | 691979.2156 | 0 | 3611527 | 131244 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC SLAB ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 115.4 | False | None | None | False | None | False | 1467624.888 | 0 | 3611528 | 131244 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR RCC STARICASE ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 12717.72 | 12717.72 | 7.07 | False | None | None | False | None | False | 89914.2804 | 0 | 3611529 | 131244 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOR LINTEL ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 13565.56 | 13565.56 | 12.12 | False | None | None | False | None | False | 164414.5872 | 0 | 3611530 | 131244 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 11911.13 | 11911.13 | 14.18 | False | None | None | False | None | False | 168899.8234 | 0 | 3611531 | 131244 | None | 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4317.92 | 4317.92 | 20.48 | False | None | None | False | None | False | 88431.0016 | 0 | 3611532 | 131244 | None | 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 141.25 | 141.25 | 36.0 | False | None | None | False | None | False | 5085.0 | 0 | 3611533 | 131244 | None | 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1642.91 | 1642.91 | 56.5 | False | None | None | False | None | False | 92824.415 | 0 | 3611534 | 131244 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 6601.39 | 6601.39 | 30.54 | False | None | None | False | None | False | 201606.4506 | 0 | 3611535 | 131244 | None | 10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4877.94 | 4877.94 | 9.69 | False | None | None | False | None | False | 47267.2386 | 0 | 3611536 | 131244 | None | 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 761.99 | 761.99 | 92.01 | False | None | None | False | None | False | 70110.6999 | 0 | 3611537 | 131244 | None | 8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 350.64 | 350.64 | 215.82 | False | None | None | False | None | False | 75675.1248 | 0 | 3611538 | 131244 | None | 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 360.55 | 360.55 | 68.92 | False | None | None | False | None | False | 24849.106 | 0 | 3611539 | 131244 | None | 9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3533.63 | 3533.63 | 11.09 | False | None | None | False | None | False | 39187.9567 | 0 | 3611540 | 131244 | None | 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 6601.39 | 6601.39 | 13.73 | False | None | None | False | None | False | 90637.0847 | 0 | 3611541 | 131244 | None | 10.1.1 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 4963.43 | 4963.43 | 3.81 | False | None | None | False | None | False | 18910.6683 | 0 | 3611542 | 131244 | None | 1.4.1 V-1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 299.84 | 299.84 | 11.06 | False | None | None | False | None | False | 3316.2304 | 0 | 3611543 | 131244 | None | 1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 320.9 | 320.9 | 1.7 | False | None | None | False | None | False | 545.53 | 0 | 3611544 | 131244 | None | 17.5 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1391.4 | 1391.4 | 7.0 | False | None | None | False | None | False | 9739.8 | 0 | 3611545 | 131244 | None | 17.1 V-2 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1241.48 | 1241.48 | 0.28 | False | None | None | False | None | False | 347.6144 | 0 | 3611546 | 131244 | None | 17.2 V-2 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1469.45 | 1469.45 | 0.14 | False | None | None | False | None | False | 205.723 | 0 | 3611547 | 131244 | None | 17. V-2 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1476.89 | 1476.89 | 0.14 | False | None | None | False | None | False | 206.7646 | 0 | 3611548 | 131244 | None | 17.4 V-2 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 1659.02 | 1659.02 | 0.14 | False | None | None | False | None | False | 232.2628 | 0 | 3611549 | 131244 | None | 17.14 V-2 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1449.63 | 1449.63 | 1.0 | False | None | None | False | None | False | 1449.63 | 0 | 3611550 | 131244 | None | V3 305.3.4 | Compacting Original Ground
Compacting original ground supporting embankment
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 130.1 | 130.1 | 72.0 | False | None | None | False | None | False | 9367.2 | 0 | 3611551 | 131244 | None | V-3 4.2 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 2922.8 | 2922.8 | 36.0 | False | None | None | False | None | False | 105220.8 | 0 | 3611552 | 131244 | None | V3 6.1 ISSUE RATE | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 6095.88 | 6095.88 | 24.0 | False | None | None | False | None | False | 146301.12 | 0 | 3611553 | 131244 | None | V-3 6.2 ISSUE RATE | Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, de-bonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 11107.64 | 11107.64 | 48.0 | False | None | None | False | None | False | 533166.72 | 0 | 3611554 | 131244 | None | V-3 8.10 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 105.32 | 105.32 | 15.0 | False | None | None | False | None | False | 1579.8 | 0 | 3611555 | 131244 | None | V-3 | Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 87.97 | 87.97 | 448.0 | False | None | None | False | None | False | 39410.56 | 0 | 3611556 | 131244 | None | V-314621A | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)
300 x 250 x 100 mm Kerb Stone
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 296.12 | 296.12 | 150.0 | False | None | None | False | None | False | 44418.0 | 0 | 3611557 | 131244 | None | 2.1.4 V-1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 7702.86 | 7702.86 | 2.0 | False | None | None | False | None | False | 15405.72 | 0 | 3611558 | 131244 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 9156.76 | 9156.76 | 10.8 | False | None | None | False | None | False | 98893.008 | 0 | 3611559 | 131244 | None | 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 459.67 | 459.67 | 320.0 | False | None | None | False | None | False | 147094.4 | 0 | 3611560 | 131244 | None | 8.31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 220.54 | 220.54 | 320.0 | False | None | None | False | None | False | 70572.8 | 0 | 3611561 | 131244 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (FOR COMPOUND WALL) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8761.09 | 8761.09 | 9.36 | False | None | None | False | None | False | 82003.8024 | 0 | 3611562 | 131244 | None | 8.20 V-3 | Providing and fixing 1.8 m high GI barbed wire fencing with
2.4 m angle iron posts 50 mm x 50 mm x 6 mm placed every 3 m center to center founded in M15 grade cement concrete,
0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 12 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 808"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 672.78 | 672.78 | 390.0 | False | None | None | False | None | False | 262384.2 | 0 | 3611563 | 131244 | None | V1 1.15.2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 m FOR SUMP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 526.58 | 526.58 | 22.51 | False | None | None | False | None | False | 11853.3158 | 0 | 3611564 | 131244 | None | 2.5.2 V1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Raft for Water tank
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 8732.83 | 8732.83 | 4.32 | False | None | None | False | None | False | 37725.8256 | 0 | 3611565 | 131244 | None | 2.5.2 V1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Outer wall water tank
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 9326.32 | 9326.32 | 5.89 | False | None | None | False | None | False | 54932.0248 | 0 | 3611566 | 131244 | None | V2 15.14 | UGT/OHT (inside) waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification SUMP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 2072.85 | 2072.85 | 36.6 | False | None | None | False | None | False | 75866.31 | 0 | 3611567 | 131244 | None | V5 18.3 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. SUMP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2430.92 | 2430.92 | 8.0 | False | None | None | False | None | False | 19447.36 | 0 | 3611568 | 131244 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RC WALL FOR SEPTIC TANK ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 14413.41 | 14413.41 | 9.87 | False | None | None | False | None | False | 142260.3567 | 0 | 3611569 | 131244 | None | 15.5 V-2 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self adhesive polymer layer, etc, including surface preparation completely as per specification. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 749.6 | 749.6 | 63.57 | False | None | None | False | None | False | 47652.072 | 0 | 3611570 | 131244 | None | 8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 110.27 | 110.27 | 20.1 | False | None | None | False | None | False | 2216.427 | 0 | 3611571 | 131244 | None | V-5P140I12.4 | Geophysical investigation of site for sinking Borewell for supplying drinking water to Habitation either through the Handpump, MWS or PWSS by vertical sounding by adopting veener sounding by adopting veener or schlumbergers's including reconassiance of survey of Geological formation,geophysical investigation of existing ground water in the vicinity quality, quantity and acceptability of the user including the location of site,recommended department of casing pipe required to seal the top and consolidated formation including an extra depth of 1.00Mtr in consolidated formation including an extra depth of drilling required to cover full depth of occupier proposed to trap probable yield and other information required including transportation of instrument and accessories to work site engaging technical personnel labour required etc complete as directed by Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3611572 | 131244 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 458.43 | 458.43 | 50.0 | False | None | None | False | None | False | 22921.5 | 0 | 3611573 | 131244 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above 50 Mtrs and upto 100 Mtr
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 574.9 | 574.9 | 50.0 | False | None | None | False | None | False | 28745.0 | 0 | 3611574 | 131244 | None | V-5P139I12.1 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig
of capacity 300 PSIG & above 1100 CMF & above in all strata including
over burdern upto 20 m. Fixing of casing pipes, collars and cap with
necessary cutting, threading and welding including transportation of
rig and supporting vehicle, crew charges and cost of consumables etc.,
complete including yield testing at the final depth with a minimum
working of compressor for one hour (Excluding cost of casing pipes,
collars, cap etc., complete ) (Above 450m of drilling add 10% for every
50m depth"
Above100 Mtrs. and upto 150 Mtr
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 610.83 | 610.83 | 50.0 | False | None | None | False | None | False | 30541.5 | 0 | 3611575 | 131244 | None | V-5P143I12.32 | Supply Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 2394.99 | 2394.99 | 20.0 | False | None | None | False | None | False | 47899.8 | 0 | 3611576 | 131244 | None | V-5P155I13.28 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 681.45 | 681.45 | 150.0 | False | None | None | False | None | False | 102217.5 | 0 | 3611577 | 131244 | None | V-5P143I12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 185.85 | 185.85 | 1.0 | False | None | None | False | None | False | 185.85 | 0 | 3611578 | 131244 | None | V-5P154I12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3611579 | 131244 | None | 18-19 SR13.81.3 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Nos | 260.19 | 260.19 | 1.0 | False | None | None | False | None | False | 260.19 | 0 | 3611580 | 131244 | None | V-5P154I13.11.5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 90 LPM @ 110 m = 10 STG Outlet Dia - 2.00" - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.
5.00 HP - 90 LPM @ 66 m = 10 STG Outlet Dia - 2.00"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 39817.74 | 39817.74 | 1.0 | False | None | None | False | None | False | 39817.74 | 0 | 3611581 | 131244 | None | V-5P155I13.23 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Up to 6 HP - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 11832.45 | 11832.45 | 1.0 | False | None | None | False | None | False | 11832.45 | 0 | 3611582 | 131244 | None | V-5P155I13.29 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets. complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 1920.45 | 1920.45 | 1.0 | False | None | None | False | None | False | 1920.45 | 0 | 3611583 | 131244 | None | V-5P155I13.31 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.
- etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 49.56 | 49.56 | 100.0 | False | None | None | False | None | False | 4956.0 | 0 | 3611584 | 131244 | None | V-5P156I13.32 | Labour charges for Erection, Electrification and commissioning works of Pump sets including aligning and balancing with all necessary erection of materials and labour including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job. as per specifications, with testing of as per instructions of engineer incharge of work - etc., complete with all lead & lift and work to be executed as per the specification and
Engineer-in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 8053.5 | 8053.5 | 1.0 | False | None | None | False | None | False | 8053.5 | 0 | 3611585 | 131244 | None | V-5P156I13.33 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 1672.65 | 1672.65 | 1.0 | False | None | None | False | None | False | 1672.65 | 0 | 3611586 | 131244 | None | 2.6.2 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 208.15 | 208.15 | 165.0 | False | None | None | False | None | False | 34344.75 | 0 | 3611587 | 131244 | None | V-5P20I5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour enameled metal paint etc., complete
16 SWG
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 30000.0 | False | None | None | False | None | False | 15900.0 | 0 | 3611588 | 131244 | None | V-5P21I5.44.4 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase /Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.
600mmx600mmx170mm.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 17990.28 | 17990.28 | 1.0 | False | None | None | False | None | False | 17990.28 | 0 | 3611589 | 131244 | None | 5.6.6 V-6 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 404.08 | 404.08 | 1.0 | False | None | None | False | None | False | 404.08 | 0 | 3611590 | 131244 | None | 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 514.19 | 514.19 | 1.0 | False | None | None | False | None | False | 514.19 | 0 | 3611591 | 131244 | None | 13.18.1 | Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.15A to 63A TPST
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 344.44 | 344.44 | 1.0 | False | None | None | False | None | False | 344.44 | 0 | 3611592 | 131244 | None | 5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kvar | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 |
| 1721828234000 | 0 | None | None | Buildings | NARAYANPUR IN SHORAPUR TALUK OF YADGIR DISTRICT (WATER SUPPLY AND SANITARY WORKS) | 2711710.47 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3611593 | 131245 | None | V-2 13.50.5 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work
40mm dia pipes, From wash basin waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 376.66 | 376.66 | 50.0 | False | None | None | False | None | False | 18833.0 | 0 | 3611594 | 131245 | None | V-2 13.50.6 | Providing and fixing normal gauge polythene pipes of approved quality Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for
cold water supply including all uPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step uPVC solvent
cement, trenching, refilling & testing of joints complete as per direction
of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 478.25 | 478.25 | 20.0 | False | None | None | False | None | False | 9565.0 | 0 | 3611595 | 131245 | None | V-2 13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
75mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 358.07 | 358.07 | 185.0 | False | None | None | False | None | False | 66242.95 | 0 | 3611596 | 131245 | None | V-2 13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This
includes jointing of pipes & fittings with one step solvent cement,
trenching, refilling & testing of joints complete as per direction of
Engineer in Charge. ( Internal drainage)
110mm nominal dia pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 477.02 | 477.02 | 120.0 | False | None | None | False | None | False | 57242.4 | 0 | 3611597 | 131245 | None | V-2 IT.NO 13.47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 244.08 | 244.08 | 35.0 | False | None | None | False | None | False | 8542.8 | 0 | 3611598 | 131245 | None | V-2 IT.NO 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 360.55 | 360.55 | 50.0 | False | None | None | False | None | False | 18027.5 | 0 | 3611599 | 131245 | None | V-2 P.NO 128 IT.NO 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 302.32 | 302.32 | 55.0 | False | None | None | False | None | False | 16627.6 | 0 | 3611600 | 131245 | None | V-2 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed
to wooden cleats with C.P. brass screws and washers complete."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1511.58 | 1511.58 | 21.0 | False | None | None | False | None | False | 31743.18 | 0 | 3611601 | 131245 | None | V-2 P.NO 127 IT.NO 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6891.32 | 6891.32 | 4.0 | False | None | None | False | None | False | 27565.28 | 0 | 3611602 | 131245 | None | V-2 P.NO 130 IT.NO 14.40.2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 614.54 | 614.54 | 4.0 | False | None | None | False | None | False | 2458.16 | 0 | 3611603 | 131245 | None | V-2 P.NO 123 IT.NO 14.38 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of
the same materials with snap fittings of approved quality and colour,
weighing not less than 105 g"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 179.66 | 179.66 | 4.0 | False | None | None | False | None | False | 718.64 | 0 | 3611604 | 131245 | None | V-2 P.NO 178 IT.NO 14.3.1 | Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush
bend, overflow arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete, including
painting of fittings and brackets, cutting and making good the walls and
floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 7405.5 | 7405.5 | 9.0 | False | None | None | False | None | False | 66649.5 | 0 | 3611605 | 131245 | None | V-2 P.NO 124 IT.NO14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6051.28 | 6051.28 | 10.0 | False | None | None | False | None | False | 60512.8 | 0 | 3611606 | 131245 | None | V-2 P.NO 126 IT.NO 14.11.2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6296.6 | 6296.6 | 2.0 | False | None | None | False | None | False | 12593.2 | 0 | 3611607 | 131245 | None | V-2 P.NO 126 IT.NO 14.10.1.1 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per
IS:13983 with C.I. brackets and stainless steel plug 40 mm, including
painting of fittings and brackets, cutting and making good the walls
wherever required : (510x1040 mm bowl depth 250 mm)"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6960.7 | 6960.7 | 4.0 | False | None | None | False | None | False | 27842.8 | 0 | 3611608 | 131245 | None | V-2 13.15 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 898.28 | 898.28 | 12.0 | False | None | None | False | None | False | 10779.36 | 0 | 3611609 | 131245 | None | V-2 P.NO 124 IT.NO 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3818.6 | 3818.6 | 13.0 | False | None | None | False | None | False | 49641.8 | 0 | 3611610 | 131245 | None | V-2 P.NO 120 IT.NO 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
15 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 382.85 | 382.85 | 90.0 | False | None | None | False | None | False | 34456.5 | 0 | 3611611 | 131245 | None | V-2 P.NO 120 IT.NO 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
20 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 469.58 | 469.58 | 70.0 | False | None | None | False | None | False | 32870.6 | 0 | 3611612 | 131245 | None | V-2 p.NO 120 IT.NO 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
25 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 70.0 | False | None | None | False | None | False | 41370.0 | 0 | 3611613 | 131245 | None | V-2 P.NO 120 IT.NO 13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
32 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 690.12 | 690.12 | 30.0 | False | None | None | False | None | False | 20703.6 | 0 | 3611614 | 131245 | None | V-2 P.NO 120 IT.NO 13.31.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
40 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 664.1 | 664.1 | 20.0 | False | None | None | False | None | False | 13282.0 | 0 | 3611615 | 131245 | None | V-2 P.NO 120IT.NO 13.31.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc."
50 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 967.66 | 967.66 | 20.0 | False | None | None | False | None | False | 19353.2 | 0 | 3611616 | 131245 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
20mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 268.86 | 268.86 | 50.0 | False | None | None | False | None | False | 13443.0 | 0 | 3611617 | 131245 | None | V-2 P.NO 120 IT.NO 13.33.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
25mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 366.74 | 366.74 | 50.0 | False | None | None | False | None | False | 18337.0 | 0 | 3611618 | 131245 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
40mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 215.0 | False | None | None | False | None | False | 127065.0 | 0 | 3611619 | 131245 | None | V-2 P.NO 120 IT.NO 13.33.7 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
65mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 1734.6 | 1734.6 | 25.0 | False | None | None | False | None | False | 43365.0 | 0 | 3611620 | 131245 | None | V-2 P.NO 120 IT.NO 13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
50mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 893.32 | 893.32 | 40.0 | False | None | None | False | None | False | 35732.8 | 0 | 3611621 | 131245 | None | V2 13.5.2 | Providing and fixing ball valve (brass) of approved quality, High or low
pressure, with plastic floats complete :"
25 mm nominal bore
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 411.35 | 411.35 | 12.0 | False | None | None | False | None | False | 4936.2 | 0 | 3611622 | 131245 | None | V2-13.4 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 32 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 740.92 | 740.92 | 7.0 | False | None | None | False | None | False | 5186.44 | 0 | 3611623 | 131245 | None | V-2 13.4.3 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 40 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 869.78 | 869.78 | 9.0 | False | None | None | False | None | False | 7828.02 | 0 | 3611624 | 131245 | None | v2-13.4.4 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) : 50 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1059.35 | 1059.35 | 2.0 | False | None | None | False | None | False | 2118.7 | 0 | 3611625 | 131245 | None | V-2,A-13, IT.NO 13.2.1 | Brass bib-cock 15 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 354.35 | 354.35 | 19.0 | False | None | None | False | None | False | 6732.65 | 0 | 3611626 | 131245 | None | V-2 IT.NO 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Ltr | 11.15 | 11.15 | 3000.0 | False | None | None | False | None | False | 33450.0 | 0 | 3611627 | 131245 | None | V2 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kg | 182.13 | 182.13 | 125.0 | False | None | None | False | None | False | 22766.25 | 0 | 3611628 | 131245 | None | Market Rate | Providing and fixing 7.50cms to 15cms dia N.P. Grating 100mm dia. (Page.91/I.No.12.111)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 177.0 | 177.0 | 55.0 | False | None | None | False | None | False | 9735.0 | 0 | 3611629 | 131245 | None | Market Rate | Air Vent Cowel
75mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 413.0 | 413.0 | 12.0 | False | None | None | False | None | False | 4956.0 | 0 | 3611630 | 131245 | None | Market Rate | Air Vent Cowel
110mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 590.0 | 590.0 | 12.0 | False | None | None | False | None | False | 7080.0 | 0 | 3611631 | 131245 | None | Market Rate | Supplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6844.0 | 6844.0 | 9.0 | False | None | None | False | None | False | 61596.0 | 0 | 3611632 | 131245 | None | Market Rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2183.0 | 2183.0 | 9.0 | False | None | None | False | None | False | 19647.0 | 0 | 3611633 | 131245 | None | Market Rate | Supplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 767.0 | 767.0 | 95.0 | False | None | None | False | None | False | 72865.0 | 0 | 3611634 | 131245 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
a) 65mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4130.0 | 4130.0 | 2.0 | False | None | None | False | None | False | 8260.0 | 0 | 3611635 | 131245 | None | Market Rate | Supplying, installing, testing and commissioning of approved make butterfly valve (upto 150mm dia with hand lever operation & above with gear box operation). Tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, G.I. flanges, G.I. nuts, G.I. bolts, G.I. washers & painting complete as required.
b) 50mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3304.0 | 3304.0 | 4.0 | False | None | None | False | None | False | 13216.0 | 0 | 3611636 | 131245 | None | V2 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Unit | 345.68 | 345.68 | 4.0 | False | None | None | False | None | False | 1382.72 | 0 | 3611637 | 131245 | None | V2 9.29 | Providing and laying flooring and steps fine dressed granite stone slabs
40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with
cement mortar 1:3 over existing cement concrete bed , including cost
of materials, mortar, labour, curing complete as per specifications."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 5335.13 | 5335.13 | 18.0 | False | None | None | False | None | False | 96032.34 | 0 | 3611638 | 131245 | None | V2 10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded
and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti
tions by cutting a chase of appropriate width with chase cutter and embed
ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 3455.57 | 3455.57 | 10.0 | False | None | None | False | None | False | 34555.7 | 0 | 3611639 | 131245 | None | V2 13.28 | Providing and fixing PTMT extension nipple for water tank pipe, fittings
of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 79.3 | 79.3 | 70.0 | False | None | None | False | None | False | 5551.0 | 0 | 3611640 | 131245 | None | 14.36.1 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of
approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g
"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 111.51 | 111.51 | 23.0 | False | None | None | False | None | False | 2564.73 | 0 | 3611641 | 131245 | None | 14.37.1 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective
length of tail pipe 260 mm from the centre of the waste coupling, 77 mm
breadth with 25 mm minimum water seal, weighing not less than 260 g"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Unit | 379.13 | 379.13 | 23.0 | False | None | None | False | None | False | 8719.99 | 0 | 3611642 | 131245 | None | 13.8.1.1 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 102.84 | 102.84 | 23.0 | False | None | None | False | None | False | 2365.32 | 0 | 3611643 | 131245 | None | 14.22.A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1003.59 | 1003.59 | 23.0 | False | None | None | False | None | False | 23082.57 | 0 | 3611644 | 131245 | None | 13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 768.18 | 768.18 | 53.0 | False | None | None | False | None | False | 40713.54 | 0 | 3611645 | 131245 | None | V2 14.63A | Providing and fixing Single lever sink mixer with swivel spout top
outlet wall mountable made of Stainless steel with all concealed fitting
arrangements & all necessary accesories complete - Class Economy "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4667.31 | 4667.31 | 4.0 | False | None | None | False | None | False | 18669.24 | 0 | 3611646 | 131245 | None | 14.4.1 | Providing and fixing white vitreous china flat back or wall corner type
lipped front urinal basin of 430x260x350 mm and 340x410x265 mm
sizes respectively with automatic flushing cistern with standard flush
pipe and C.P. brass spreaders with brass unions and G.I clamps complete,
including painting of fittings and brackets, cutting and making good the
walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 5518.51 | 5518.51 | 4.0 | False | None | None | False | None | False | 22074.04 | 0 | 3611647 | 131245 | None | ELE 7.3 | Supplying, installation, testing and commissioning of solar hot water
heater comprising of solar Flat Plate Collector (FPC) of size
2120x1040x100mm and stainless steel hot water storage tank with
stainless steel heat exchanger absorber made of copper sheet and
copper tube of following capacity aluminium box collector with
appropriate capacity electrical back up arrangement excluding inlet
and out let pipes. SS Model with 100mm thick of 48Kg/M3 density
Rock wool insulation with 22SWG Aluminium cladding."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 39372.94 | 39372.94 | 3.0 | False | None | None | False | None | False | 118118.82 | 0 | 3611648 | 131245 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-110mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 944.0 | 944.0 | 10.0 | False | None | None | False | None | False | 9440.0 | 0 | 3611649 | 131245 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-75mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 767.0 | 767.0 | 2.0 | False | None | None | False | None | False | 1534.0 | 0 | 3611650 | 131245 | None | A.R | Drilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.
Core cut-160MM dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1298.0 | 1298.0 | 1.0 | False | None | None | False | None | False | 1298.0 | 0 | 3611651 | 131245 | None | V-1,P.NO 6,IT.NO 1.4.1 | Earth work excavation by manual means for drains,canals, waste weir,
draft, approach channels, key trenches, foundation of bridges and
such simillar works in all kinds of soils , as per drawing and technical
specifications, including setting out, shoring, strutting, barricading,
caution lights, removal of stumps and other deleterious matter,
excavated surface leveled and sides neatly dressed disposing off the
excavated stuff or sorting & stacking the selected stuff for reuse in a
radius of 50 m and lift upto 1.5 m including cost of labour, tools & other
appurtenaces required to complete the work."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 299.84 | 299.84 | 224.0 | False | None | None | False | None | False | 67164.16 | 0 | 3611652 | 131245 | None | V-1 P.NO 7 IT.NO 1.11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Cum | 536.49 | 536.49 | 224.0 | False | None | None | False | None | False | 120173.76 | 0 | 3611653 | 131245 | None | V-5 P.NO 134 IT.NO 10.3 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013
with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of
elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing
the pipes alround to a depth of not less than 15 cms. with soft gravel
or selected earth available from the excavation etc. complete and giving
necessary hydraulic test to the required pressure as per ISS (contractor
will make his own arrangements for procuring water for testing) etc.
complete. for:"
Pipes of SN8 Self Fit - 160mm dia.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 764.46 | 764.46 | 300.0 | False | None | None | False | None | False | 229338.0 | 0 | 3611654 | 131245 | None | V-5 P.NO 134 IT.NO 10.2.4 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ).
- do - 160 mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 713.66 | 713.66 | 70.0 | False | None | None | False | None | False | 49956.2 | 0 | 3611655 | 131245 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(INSPECTION CHAMBER)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6757.51 | 6757.51 | 45.0 | False | None | None | False | None | False | 304087.95 | 0 | 3611656 | 131245 | None | V-5 P.NO 187 IT.NO 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6757.51 | 6757.51 | 15.0 | False | None | None | False | None | False | 101362.65 | 0 | 3611657 | 131245 | None | 13.39 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete
with C.I. grating brick masonry chamber 150 x 100 mm size P type With
Non Modular common burnt clay bricks of designation 3.5 & with water
tight C.I. cover with frame of 300 x300 mm size (inside) the weight of
cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as
per standard design:"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3197.86 | 3197.86 | 25.0 | False | None | None | False | None | False | 79946.5 | 0 | 3611658 | 131245 | None | 16.18 | Construction of RCC Machinehole chambers of 1:1.5:3 proportion
or approved type Cast-insitu / Pre-cast RCC Machinehole chambers,
constructed using form vibrators of standard type, with barricading,
danger lighting and using of sight rails and boning rods wherever
necessary, shoring and strutting wherever required using Ordinary
Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down
graded jelly, well graded sand and steel of approved quality, 200 mm
thick top concrete slab, having wall thickness and raft thickness as in
approved drawings and with an offset in raft alround the chamber as
in approved drawing, benching concrete with 1:6 slope towards the
central drain finished smooth, including fixing and grouting of pipes,
including conveying to work spot supply and fixing SFRC Machinehole
cover and frame (Heavy duty) conforming to IS:12592 with latest
amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3
mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia.
Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as
detailed in Technical specifications, including stone grit beding wherever
required, watering, curing, engraving Machinehole number with flow
direction on the inner cylindrical surface etc., complete including
cost of reinforcement steel and fabrication charges and also cost and
conveyance of all materials, labour with all lead and lifts. The Pre-cast
RCC Machinehole are for various diamters and depths as stated below
and as per detailed drawings, specifications and direction of the Engineer.
For 1.2m dia Machinehole:"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 97246.63 | 97246.63 | 1.0 | False | None | None | False | None | False | 97246.63 | 0 | 3611659 | 131245 | None | V-2 P.NO 120 IT.NO 13.33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work)
External & Shafts & Terrace
40mm DWS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 591.0 | 591.0 | 80.0 | False | None | None | False | None | False | 47280.0 | 0 | 3611660 | 131245 | None | 13.23 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (50 mm nominal bore, 242mm long, weighing not less than 1240 g)
T.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1665.22 | 1665.22 | 5.0 | False | None | None | False | None | False | 8326.1 | 0 | 3611661 | 131245 | None | 13.40.1 V-5 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 19340.79 | 19340.79 | 2.0 | False | None | None | False | None | False | 38681.58 | 0 | 3611662 | 131245 | None | 13.32 V-5 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and
equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work."
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 8053.5 | 8053.5 | 2.0 | False | None | None | False | None | False | 16107.0 | 0 |
| 1721828234000 | 0 | None | None | Buildings | NARAYANPUR IN SHORAPUR TALUK OF YADGIR DISTRICT (ELECTRICAL WORKS) | 4364380.98 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3611663 | 131246 | None | PWD ELE SR V-6 IT.NO 2.2.1 | WIRES & CABLES
Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Short point up to 3Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 333.29 | 333.29 | 25.0 | False | None | None | False | None | False | 8332.25 | 0 | 3611664 | 131246 | None | PWD ELE SR V-10 IT.NO 2.2.2 | Point wiring using Copper wire without switch.
"Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet."
Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Pack | 469.58 | 469.58 | 36.0 | False | None | None | False | None | False | 16904.88 | 0 | 3611665 | 131246 | None | PWD ELE SR V-11 IT.NO 2.2.3 | Point wiring using Copper wire without switch.
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Long point above 6Mtr up to 10Mtr from tapping point to out let via switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 687.65 | 687.65 | 63.0 | False | None | None | False | None | False | 43321.95 | 0 | 3611666 | 131246 | None | PWD ELE SR V-12 IT.NO 2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet.
Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 838.8 | 838.8 | 8.0 | False | None | None | False | None | False | 6710.4 | 0 | 3611667 | 131246 | None | PWD ELE SR V-14 IT.NO 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
1-3Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 170.98 | 170.98 | 25.0 | False | None | None | False | None | False | 4274.5 | 0 | 3611668 | 131246 | None | PWD ELE SR V-15 IT.NO 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
4-5Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 197.0 | 197.0 | 32.0 | False | None | None | False | None | False | 6304.0 | 0 | 3611669 | 131246 | None | PWD ELE SR V-16 IT.NO 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
6Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 219.3 | 219.3 | 16.0 | False | None | None | False | None | False | 3508.8 | 0 | 3611670 | 131246 | None | PWD ELE SR V-17 IT.NO 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
8 Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 272.58 | 272.58 | 7.0 | False | None | None | False | None | False | 1908.06 | 0 | 3611671 | 131246 | None | PWD ELE SR V-18 IT.NO 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall
10-12Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 323.38 | 323.38 | 20.0 | False | None | None | False | None | False | 6467.6 | 0 | 3611672 | 131246 | None | PWD ELE SR V-20 IT.NO 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
1 to 3 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 199.48 | 199.48 | 32.0 | False | None | None | False | None | False | 6383.36 | 0 | 3611673 | 131246 | None | PWD ELE SR V-21 IT.NO 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
4 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 216.83 | 216.83 | 16.0 | False | None | None | False | None | False | 3469.28 | 0 | 3611674 | 131246 | None | PWD ELE SR V-22 IT.NO 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
6 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 289.93 | 289.93 | 7.0 | False | None | None | False | None | False | 2029.51 | 0 | 3611675 | 131246 | None | PWD ELE SR V-23 IT.NO 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
8 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 351.88 | 351.88 | 21.0 | False | None | None | False | None | False | 7389.48 | 0 | 3611676 | 131246 | None | PWD ELE SR V-24 IT.NO 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.
10-12 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 426.22 | 426.22 | 31.0 | False | None | None | False | None | False | 13212.82 | 0 | 3611677 | 131246 | None | PWD ELE SR V-26 IT.NO 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps one way Switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 126.38 | 126.38 | 217.0 | False | None | None | False | None | False | 27424.46 | 0 | 3611678 | 131246 | None | PWD ELE SR V-6 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps Two way Switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 205.67 | 205.67 | 2.0 | False | None | None | False | None | False | 411.34 | 0 | 3611679 | 131246 | None | PWD ELE SR V-6,IT.NO 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6Amps 3way socket
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 211.87 | 211.87 | 81.0 | False | None | None | False | None | False | 17161.47 | 0 | 3611680 | 131246 | None | PWD ELE SR V-6,IT.NO 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Stepped Fan Regulator.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 442.32 | 442.32 | 24.0 | False | None | None | False | None | False | 10615.68 | 0 | 3611681 | 131246 | None | PWD ELE SR V-6,IT.NO 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
16Amps one way switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 223.02 | 223.02 | 10.0 | False | None | None | False | None | False | 2230.2 | 0 | 3611682 | 131246 | None | PWD ELE SR V-6, IT.NO 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
32Amps DP switch
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 403.91 | 403.91 | 15.0 | False | None | None | False | None | False | 6058.65 | 0 | 3611683 | 131246 | None | PWD ELE SR V-6,IT.NO 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
6/16Amps universal socket
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 292.4 | 292.4 | 25.0 | False | None | None | False | None | False | 7310.0 | 0 | 3611684 | 131246 | None | PWD ELE SR V-6,IT.NO 1.13 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
Supplyin and Fixing Metal Fan Box with Round Hook.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 144.96 | 144.96 | 24.0 | False | None | None | False | None | False | 3479.04 | 0 | 3611685 | 131246 | None | PWD ELE SR V-6,IT.NO-1.2.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
19/20mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 81.77 | 81.77 | 890.0 | False | None | None | False | None | False | 72775.3 | 0 | 3611686 | 131246 | None | PWD ELE SR V-6,IT.NO 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
25mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 96.64 | 96.64 | 1030.0 | False | None | None | False | None | False | 99539.2 | 0 | 3611687 | 131246 | None | PWD ELE SR V-6, IT.NO .2.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)
32mm dia 2.5mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 127.62 | 127.62 | 250.0 | False | None | None | False | None | False | 31905.0 | 0 | 3611688 | 131246 | None | PWD ELE SR V-6,IT.NO1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
19/20mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 84.25 | 84.25 | 445.0 | False | None | None | False | None | False | 37491.25 | 0 | 3611689 | 131246 | None | PWD ELE SR V-6,IT.NO-1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 97.88 | 97.88 | 515.0 | False | None | None | False | None | False | 50408.2 | 0 | 3611690 | 131246 | None | PWD ELE SR V-6,IT.NO-1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.
32mm dia 2.5mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 122.66 | 122.66 | 150.0 | False | None | None | False | None | False | 18399.0 | 0 | 3611691 | 131246 | None | PWD ELE SR V-6,IT.NO 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
1.5 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 32.21 | 32.21 | 470.0 | False | None | None | False | None | False | 15138.7 | 0 | 3611692 | 131246 | None | PWD ELE SR V-6,IT.NO 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
2.5 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 52.04 | 52.04 | 1530.0 | False | None | None | False | None | False | 79621.2 | 0 | 3611693 | 131246 | None | PWD ELE SR V-6,IT.NO 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
4 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 78.06 | 78.06 | 740.0 | False | None | None | False | None | False | 57764.4 | 0 | 3611694 | 131246 | None | PWD ELE SR V-6,IT.NO 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.
6 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 113.99 | 113.99 | 580.0 | False | None | None | False | None | False | 66114.2 | 0 | 3611695 | 131246 | None | PWD ELE SR V-6,IT.NO 5.19.11 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure
III - Double Door
4 Way TP & N
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 5003.08 | 5003.08 | 2.0 | False | None | None | False | None | False | 10006.16 | 0 | 3611696 | 131246 | None | PWD ELE SR V-6,IT.NO 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
6-32Amps SP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 514.19 | 514.19 | 62.0 | False | None | None | False | None | False | 31879.78 | 0 | 3611697 | 131246 | None | PWD ELE SR V-6 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (47/6.16)
40Amps TPN
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3771.52 | 3771.52 | 2.0 | False | None | None | False | None | False | 7543.04 | 0 | 3611698 | 131246 | None | PWD ELE SR V-6,IT.NO 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board
16-25 Amps 2 pole
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 5299.2 | 5299.2 | 2.0 | False | None | None | False | None | False | 10598.4 | 0 | 3611699 | 131246 | None | PWD ELE SR V-6,IT.NO 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only)
32mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 480.73 | 480.73 | 10.0 | False | None | None | False | None | False | 4807.3 | 0 | 3611700 | 131246 | None | PWD ELE SR V-6,IT.NO 6.17.8 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.
35 sqmm Long Barrel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 39.65 | 39.65 | 16.0 | False | None | None | False | None | False | 634.4 | 0 | 3611701 | 131246 | None | V-6 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4348.89 | 4348.89 | 7.0 | False | None | None | False | None | False | 30442.23 | 0 | 3611702 | 131246 | None | V-6 12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
25x3mm GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 101.6 | 101.6 | 100.0 | False | None | None | False | None | False | 10160.0 | 0 | 3611703 | 131246 | None | 12.58.6 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
600X600X3 GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1084.13 | 1084.13 | 6.0 | False | None | None | False | None | False | 6504.78 | 0 | 3611704 | 131246 | None | 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10 12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1096.52 | 1096.52 | 19.0 | False | None | None | False | None | False | 20833.88 | 0 | 3611705 | 131246 | None | 11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 1640.44 | 1640.44 | 5.0 | False | None | None | False | None | False | 8202.2 | 0 | 3611706 | 131246 | None | 11.3.2 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 854.91 | 854.91 | 51.0 | False | None | None | False | None | False | 43600.41 | 0 | 3611707 | 131246 | None | 11.11.3 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 184.61 | 184.61 | 15.0 | False | None | None | False | None | False | 2769.15 | 0 | 3611708 | 131246 | None | PWD ELE SR V-6,IT.NO 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1848.59 | 1848.59 | 13.0 | False | None | None | False | None | False | 24031.67 | 0 | 3611709 | 131246 | None | PWD ELE SR V-6,IT.NO 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3316.8 | 3316.8 | 24.0 | False | None | None | False | None | False | 79603.2 | 0 | 3611710 | 131246 | None | PWD ELE SR V-6,IT.NO 13.11 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.
On wall / ceiling / Rafter / Girders
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 390.29 | 390.29 | 24.0 | False | None | None | False | None | False | 9366.96 | 0 | 3611711 | 131246 | None | PWD ELE SR V-6,IT.NO 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 151.16 | 151.16 | 83.0 | False | None | None | False | None | False | 12546.28 | 0 | 3611712 | 131246 | None | PWD ELE SR V-6,IT.NO 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 875.97 | 875.97 | 13.0 | False | None | None | False | None | False | 11387.61 | 0 | 3611713 | 131246 | None | PWD ELE SR V-6,IT.NO 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 200.72 | 200.72 | 3.0 | False | None | None | False | None | False | 602.16 | 0 | 3611714 | 131246 | None | PWD ELE SR V-6,IT.NO 5.42.1 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete
16SWG
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 86000.0 | False | None | None | False | None | False | 45580.0 | 0 | 3611715 | 131246 | None | PWD ELE SR V-6,IT.NO 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 4255.97 | 4255.97 | 5.0 | False | None | None | False | None | False | 21279.85 | 0 | 3611716 | 131246 | None | PWD ELE SR V-6,IT.NO 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
40x40x6mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 377.9 | 377.9 | 10.0 | False | None | None | False | None | False | 3779.0 | 0 | 3611717 | 131246 | None | PWD ELE SR V-6,IT.NO 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint
50x100x50x6mm C channel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 936.68 | 936.68 | 10.0 | False | None | None | False | None | False | 9366.8 | 0 | 3611718 | 131246 | None | PWD ELE SR V-6,IT.NO 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs)
100Amps 25kA
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 10515.39 | 10515.39 | 1.0 | False | None | None | False | None | False | 10515.39 | 0 | 3611719 | 131246 | None | PWD ELE SR V-6,iT.NO 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898
50-63Amps DP
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3826.03 | 3826.03 | 10.0 | False | None | None | False | None | False | 38260.3 | 0 | 3611720 | 131246 | None | PWD ELE SR V-6,IT.NO 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 11541.29 | 11541.29 | 1.0 | False | None | None | False | None | False | 11541.29 | 0 | 3611721 | 131246 | None | PWD ELE SR V-6,IT.NO 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3611722 | 131246 | None | PWD ELE SR V-6,IT.NO 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 696.32 | 696.32 | 3.0 | False | None | None | False | None | False | 2088.96 | 0 | 3611723 | 131246 | None | PWD ELE SR V-6,IT.NO5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Kvar | 594.72 | 594.72 | 15.0 | False | None | None | False | None | False | 8920.8 | 0 | 3611724 | 131246 | None | 5.19.9 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 2885.63 | 2885.63 | 2.0 | False | None | None | False | None | False | 5771.26 | 0 | 3611725 | 131246 | None | 5.19.12 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6120.66 | 6120.66 | 1.0 | False | None | None | False | None | False | 6120.66 | 0 | 3611726 | 131246 | None | 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3826.03 | 3826.03 | 1.0 | False | None | None | False | None | False | 3826.03 | 0 | 3611727 | 131246 | None | 5.20.8 | Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 6377.13 | 6377.13 | 3.0 | False | None | None | False | None | False | 19131.39 | 0 | 3611728 | 131246 | None | 32.05 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 109549.9 | 109549.9 | 0.1 | False | None | None | False | None | False | 10954.99 | 0 | 3611729 | 131246 | None | 32.09 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 190882.82 | 190882.82 | 0.05 | False | None | None | False | None | False | 9544.141 | 0 | 3611730 | 131246 | None | 32.13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 393892.97 | 393892.97 | 0.1 | False | None | None | False | None | False | 39389.297 | 0 | 3611731 | 131246 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 25877.75 | 25877.75 | 0.05 | False | None | None | False | None | False | 1293.8875 | 0 | 3611732 | 131246 | None | 31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 38581.22 | 38581.22 | 0.2 | False | None | None | False | None | False | 7716.244 | 0 | 3611733 | 131246 | None | 6.17.6 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 15.41 | 15.41 | 20.0 | False | None | None | False | None | False | 308.2 | 0 | 3611734 | 131246 | None | 16.17.10 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 148.68 | 148.68 | 16.0 | False | None | None | False | None | False | 2378.88 | 0 | 3611735 | 131246 | None | 11.11.5 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 333.29 | 333.29 | 9.0 | False | None | None | False | None | False | 2999.61 | 0 | 3611736 | 131246 | None | 11.6.3 | Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decastextruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 5641.17 | 5641.17 | 8.0 | False | None | None | False | None | False | 45129.36 | 0 | 3611737 | 131246 | None | 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 4985.74 | 4985.74 | 2.0 | False | None | None | False | None | False | 9971.48 | 0 | 3611738 | 131246 | None | 13.4.1 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1810.18 | 1810.18 | 3.0 | False | None | None | False | None | False | 5430.54 | 0 | 3611739 | 131246 | None | 5.14.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 2738.19 | 2738.19 | 2.0 | False | None | None | False | None | False | 5476.38 | 0 | 3611740 | 131246 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 169.74 | 169.74 | 24.0 | False | None | None | False | None | False | 4073.76 | 0 | 3611741 | 131246 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 395.24 | 395.24 | 31.0 | False | None | None | False | None | False | 12252.44 | 0 | 3611742 | 131246 | None | 2.2.5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Point | 1225.37 | 1225.37 | 4.0 | False | None | None | False | None | False | 4901.48 | 0 | 3611743 | 131246 | None | 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 144.96 | 144.96 | 6.0 | False | None | None | False | None | False | 869.76 | 0 | 3611744 | 131246 | None | 12.46 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 78.06 | 78.06 | 21.0 | False | None | None | False | None | False | 1639.26 | 0 | 3611745 | 131246 | None | 3.6.11 | TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 193.28 | 193.28 | 2.0 | False | None | None | False | None | False | 386.56 | 0 | 3611746 | 131246 | None | 12.2.1 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 304.79 | 304.79 | 1.0 | False | None | None | False | None | False | 304.79 | 0 | 3611747 | 131246 | None | 32.02 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 98168.45 | 98168.45 | 0.1 | False | None | None | False | None | False | 9816.845 | 0 | 3611748 | 131246 | None | 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 25877.75 | 25877.75 | 0.1 | False | None | None | False | None | False | 2587.775 | 0 | 3611749 | 131246 | None | pwd sr | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 15.41 | 15.41 | 15.0 | False | None | None | False | None | False | 231.15 | 0 | 3611750 | 131246 | None | 11..11.7 | Supplying & fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500-degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 527.81 | 527.81 | 3.0 | False | None | None | False | None | False | 1583.43 | 0 | 3611751 | 131246 | None | 12.27 | Supplying & Fixing of Special Type pigmy and candle lamp.
Operating voltage range from 180V to 265V, 50Hz AC power Supply"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 64.43 | 64.43 | 2.0 | False | None | None | False | None | False | 128.86 | 0 | 3611752 | 131246 | None | 11.8.1 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 3004.58 | 3004.58 | 1.0 | False | None | None | False | None | False | 3004.58 | 0 | 3611753 | 131246 | None | 5.7.2 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 298.6 | 298.6 | 1.0 | False | None | None | False | None | False | 298.6 | 0 | 3611754 | 131246 | None | 5.30 | Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 1709.82 | 1709.82 | 1.0 | False | None | None | False | None | False | 1709.82 | 0 | 3611755 | 131246 | None | 7.1.3 | Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 12689.84 | 12689.84 | 1.0 | False | None | None | False | None | False | 12689.84 | 0 | 3611756 | 131246 | None | PWD SR 2023-24 Volume 6 It No-9.3.3 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 84726.54 | 84726.54 | 1.0 | False | None | None | False | None | False | 84726.54 | 0 | 3611757 | 131246 | None | PWD SR 2023-24 Volume 6 It No-9.5.9 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150AH capacity
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 19693.91 | 19693.91 | 4.0 | False | None | None | False | None | False | 78775.64 | 0 | 3611758 | 131246 | None | A.R | Item Name : The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration &proof checking by reputedGovernment/Semi Government/IISC /IIT/NIT/or as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure, etc. Interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project and 6 sets of as built drawings should be submitted to the employer. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Job | 300000.0 | 300000.0 | 1.0 | False | None | None | False | None | False | 300000.0 | 0 | 3611759 | 131246 | None | LQR | IP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 23836.0 | 23836.0 | 4.0 | False | None | None | False | None | False | 95344.0 | 0 | 3611760 | 131246 | None | LQR | IP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 25606.0 | 25606.0 | 2.0 | False | None | None | False | None | False | 51212.0 | 0 | 3611761 | 131246 | None | LQR | Supplying, installation, testing and commissioning of SITC of complete 8 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3611762 | 131246 | None | LQR | Supply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 17110.0 | 17110.0 | 2.0 | False | None | None | False | None | False | 34220.0 | 0 | 3611763 | 131246 | None | LQR | Supply and Installation of I/Os
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 147.5 | 147.5 | 12.0 | False | None | None | False | None | False | 1770.0 | 0 | 3611764 | 131246 | None | LQR | Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 265.5 | 265.5 | 12.0 | False | None | None | False | None | False | 3186.0 | 0 | 3611765 | 131246 | None | LQR | Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 336.3 | 336.3 | 6.0 | False | None | None | False | None | False | 2017.8 | 0 | 3611766 | 131246 | None | LQR | Supply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 3611767 | 131246 | None | V-6 8.1 | Supplying and drawing UTP-CAT 6E LAN cable
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 47.08 | 47.08 | 600.0 | False | None | None | False | None | False | 28248.0 | 0 | 3611768 | 131246 | None | 1.2.2 | Supplying heavy gauge PVC Consealed conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 96.64 | 96.64 | 500.0 | False | None | None | False | None | False | 48320.0 | 0 | 3611769 | 131246 | None | 8.12.3 | Supplying & Fixing of Patch panel for LAN cabling .16 Port 10/100 patch panel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 3778.95 | 3778.95 | 1.0 | False | None | None | False | None | False | 3778.95 | 0 | 3611770 | 131246 | None | 8.4.1 v-6 | Supplying & Fixing of switch mounting rack with power manager & Cable manager 4U with 450mm depth
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 6061.19 | 6061.19 | 1.0 | False | None | None | False | None | False | 6061.19 | 0 | 3611771 | 131246 | None | 1.01 | Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 8767.16 | 8767.16 | 8.0 | False | None | None | False | None | False | 70137.28 | 0 | 3611772 | 131246 | None | 2.02 | Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 1379.01 | 1379.01 | 8.0 | False | None | None | False | None | False | 11032.08 | 0 | 3611773 | 131246 | None | 6.05 | Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 107.79 | 107.79 | 6.0 | False | None | None | False | None | False | 646.74 | 0 | 3611774 | 131246 | None | 13.12 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 59.47 | 59.47 | 6.0 | False | None | None | False | None | False | 356.82 | 0 | 3611775 | 131246 | None | 2.16 | Supply of Spiral Earth Electrode
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 296.12 | 296.12 | 11.0 | False | None | None | False | None | False | 3257.32 | 0 | 3611776 | 131246 | None | 2.16 | Erection of Spiral Earth Electrode
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 115.23 | 115.23 | 11.0 | False | None | None | False | None | False | 1267.53 | 0 | 3611777 | 131246 | None | 68.17 | Supply and fixing of Caution/Danger Board
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 185.85 | 185.85 | 6.0 | False | None | None | False | None | False | 1115.1 | 0 | 3611778 | 131246 | None | 4.02 | Supply of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 110.27 | 110.27 | 8.0 | False | None | None | False | None | False | 882.16 | 0 | 3611779 | 131246 | None | 5.09 | Erection of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 52.04 | 52.04 | 8.0 | False | None | None | False | None | False | 416.32 | 0 | 3611780 | 131246 | None | 24.05 | Supply and fixing of 11 kV, 400 Amps Double Break GOS
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 26341.14 | 26341.14 | 1.0 | False | None | None | False | None | False | 26341.14 | 0 | 3611781 | 131246 | None | 24.07 | Supply and fixing of H-Frame for mounting GOS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 7521.97 | 7521.97 | 1.0 | False | None | None | False | None | False | 7521.97 | 0 | 3611782 | 131246 | None | 25.01 | Supply of DOLO Cut Out
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set of 3 Nos | 7279.13 | 7279.13 | 1.0 | False | None | None | False | None | False | 7279.13 | 0 | 3611783 | 131246 | None | 13.01 | Erection of DOLO Cut Out
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set of 3 Nos | 293.64 | 293.64 | 1.0 | False | None | None | False | None | False | 293.64 | 0 | 3611784 | 131246 | None | 13.07 | Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 210958.34 | 210958.34 | 1.0 | False | None | None | False | None | False | 210958.34 | 0 | 3611785 | 131246 | None | 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 4348.89 | 4348.89 | 8.0 | False | None | None | False | None | False | 34791.12 | 0 | 3611786 | 131246 | None | 12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | MT | 158.59 | 158.59 | 100.0 | False | None | None | False | None | False | 15859.0 | 0 | 3611787 | 131246 | None | 12.58.9 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 2035.68 | 2035.68 | 100.0 | False | None | None | False | None | False | 203568.0 | 0 | 3611788 | 131246 | None | 12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 9194.62 | 9194.62 | 10.0 | False | None | None | False | None | False | 91946.2 | 0 | 3611789 | 131246 | None | 45.07 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 5039.01 | 5039.01 | 4.0 | False | None | None | False | None | False | 20156.04 | 0 | 3611790 | 131246 | None | 45.04 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 3887.98 | 3887.98 | 2.0 | False | None | None | False | None | False | 7775.96 | 0 | 3611791 | 131246 | None | 36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 1102296.17 | 1102296.17 | 0.1 | False | None | None | False | None | False | 110229.617 | 0 | 3611792 | 131246 | None | 38. | Providing chain link fencing 50 mm size of 8 guage properly stretched between
rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be
welded to the Pole and block pipe at top and bottom as required including cost
of all materials, labour, lead and lifts, cutting, bending wherever necessary,
wastage and lapping etc., complete as per the direction of the engineer
incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sqm | 1222.89 | 1222.89 | 150.0 | False | None | None | False | None | False | 183433.5 | 0 | 3611793 | 131246 | None | 5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Sq CM | 0.53 | 0.53 | 176000.0 | False | None | None | False | None | False | 93280.0 | 0 | 3611794 | 131246 | None | 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 4255.97 | 4255.97 | 6.0 | False | None | None | False | None | False | 25535.82 | 0 | 3611795 | 131246 | None | 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 377.9 | 377.9 | 12.0 | False | None | None | False | None | False | 4534.8 | 0 | 3611796 | 131246 | None | 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 936.68 | 936.68 | 12.0 | False | None | None | False | None | False | 11240.16 | 0 | 3611797 | 131246 | None | 5.15.15 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 29172.26 | 29172.26 | 1.0 | False | None | None | False | None | False | 29172.26 | 0 | 3611798 | 131246 | None | 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 3611799 | 131246 | None | 10.1.3 | Supplying, installing, testing and commissioning of 25KVA/20kw Diesel Generator set(CPCB-4) with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have +
1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating
lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting
battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr
at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 558914.14 | 558914.14 | 1.0 | False | None | None | False | None | False | 558914.14 | 0 | 3611800 | 131246 | None | 10.2.2 | Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the
accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 25 KVA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 72742.93 | 72742.93 | 1.0 | False | None | None | False | None | False | 72742.93 | 0 | 3611801 | 131246 | None | A.R | Supply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc.
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 3540.0 | 3540.0 | 5.0 | False | None | None | False | None | False | 17700.0 | 0 | 3611802 | 131246 | None | A.R | Supply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Rmtr | 236.0 | 236.0 | 50.0 | False | None | None | False | None | False | 11800.0 | 0 | 3611803 | 131246 | None | 58.02 | LT Metering Cubicle at Low Tension for 50KW to 150KW having specification and design as per the prototype approval (Excluding Meter cost and modem cost)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 98973.8 | 98973.8 | 1.0 | False | None | None | False | None | False | 98973.8 | 0 | 3611804 | 131246 | None | 53.01 | CT PT Operated ETV Meter 0.2s Accuracy class with ABT feature and DLMS protocal with ToD with RS232 Port UNIDIRACTIONAL ( Used for HT Installation, LT Metering Cubicle (50-150KW)
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 24302.99 | 24302.99 | 1.0 | False | None | None | False | None | False | 24302.99 | 0 | 3611805 | 131246 | None | 10.01 | Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Each | 173.46 | 173.46 | 15.0 | False | None | None | False | None | False | 2601.9 | 0 | 3611806 | 131246 | None | v-6 2.02 | Supply of 11 kV, Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr
Long, 145 Kg WL"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 603.39 | 603.39 | 6.0 | False | None | None | False | None | False | 3620.34 | 0 | 3611807 | 131246 | None | v-6 2.02 | Erection of 11 kV, Horizontal Cross Arm with clamps, HTST
supports, bolts, nuts and washers for RCC Pole - 9 Mtr
Long, 145 Kg WL"
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 318.42 | 318.42 | 6.0 | False | None | None | False | None | False | 1910.52 | 0 | 3611808 | 131246 | None | v-6 6.06 | Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP
Rod) "
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 254.0 | 254.0 | 18.0 | False | None | None | False | None | False | 4572.0 | 0 | 3611809 | 131246 | None | v-6 6.10 | Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 235.45 | 235.45 | 18.0 | False | None | None | False | None | False | 4238.1 | 0 | 3611810 | 131246 | None | 13.12 v-6 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | No | 59.47 | 59.47 | 18.0 | False | None | None | False | None | False | 1070.46 | 0 | 3611811 | 131246 | None | v-6 6.08 | Supply and fixing of 15 Strain Insulator ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Set | 73.1 | 73.1 | 4.0 | False | None | None | False | None | False | 292.4 | 0 | 3611812 | 131246 | None | 7.02 | Supply of Rabbit ACSR Conductor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 57283.93 | 57283.93 | 1.0 | False | None | None | False | None | False | 57283.93 | 0 | 3611813 | 131246 | None | 6.02 V-6 | Erection of Rabbit ACSR Conductor
---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work | Km | 5403.28 | 5403.28 | 1.0 | False | None | None | False | None | False | 5403.28 | 0 |
|
|
---|