createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721296674280
version11
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd1500000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose26-08-2024 17:30:00
tenderQueryClose20-08-2024 17:30:00
technicalBidOpen28-08-2024 10:30:00
publishedDate25-07-2024 11:54:09
publishedByPostPWD_EE_DIV_UDP
publishedByUserKPE15146 - KIRAN S
bidValidityPeriod90
noOfCalls1
preBidMeetingDate21-08-2024 10:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonShanthala.J.G
splitEmdRequiredYnTrue
emdBankGuarantee1400000.00
emdCash100000.00
bgValidityPeriod180
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08202531802
mobileNumber7019413273
tenderSupplierListNone
tenderSchedule
createdTs1721296674313
version11
createdDateNone
modifiedDateNone
tenderNumberPWD/2024-25/BD/WORK_INDENT10765
titleConstruction of Annex court building in Udupi court Premises with Advocates Bhavan & ADR complex in Udupi Dist. (Stage-1)
descriptionConstruction of Annex court building in Udupi court Premises with Advocates Bhavan & ADR complex in Udupi Dist. (Stage-1)
categoryWORKS
categoryTextWorks
ecv114647893.59
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1698
locationNamePWD Division Office Udupi
provisionalAmount151400000.0
groupOverheadTotal0.0
fileNumberKPWD/UDP/AnnexCourtbuilding/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17212966740000NoneNoneBuildingsConstruction of Annex court building in Udupi court Premises with Advocates Bhavan & ADR complex in Udupi Dist.100901196.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3541661127865None1.14.1 V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum119.95119.958392.02FalseNoneNoneFalseNoneFalse1006622.7990
3541662127865None1.14.2 v-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m to 6.00 m ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum131.04131.048392.02FalseNoneNoneFalseNoneFalse1099690.30080
3541663127865None1.14.3 V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth Above 6.00 m ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum161.28161.287308.81FalseNoneNoneFalseNoneFalse1178764.87680
3541664127865None1.15.1 V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum406.56406.56628.52FalseNoneNoneFalseNoneFalse255531.09120
3541665127865None4.1 V-2Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm132.16132.162763.95FalseNoneNoneFalseNoneFalse365283.6320
3541666127865None2.1.3 V-1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum6707.686707.68553.18FalseNoneNoneFalseNoneFalse3710554.42240
3541667127865None2.2.3 V-1Providing and laying in position Cement Concrete for all Foundation works. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Footing the cost of form work included) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum7664.037664.031355.1FalseNoneNoneFalseNoneFalse10385527.0530
3541668127865None2.4.3 V-1Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Column below basement (The cost of form work included) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum12063.7412063.7482.62FalseNoneNoneFalseNoneFalse996706.19880
3541669127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.- Columns a) Basement-1 (The cost of form work included) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum13029.0713029.0796.13FalseNoneNoneFalseNoneFalse1252484.49910
3541670127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.- Columns b) Basement-2 (The cost of form work included) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum13029.0713029.0791.62FalseNoneNoneFalseNoneFalse1193723.39340
3541671127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.- Columns c)Ground Floor (The cost of form work included) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum13029.0713029.0799.29FalseNoneNoneFalseNoneFalse1293656.36030
3541672127865None2.4.2 V-1Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - First floor dummy column. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum12159.3812159.3829.79FalseNoneNoneFalseNoneFalse362227.93020
3541673127865None2.4.3 V-1Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Plinth Beam (The cost of form work included) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum10644.4810644.4880.04FalseNoneNoneFalseNoneFalse851984.17920
3541674127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (P.16/2.5.2) - a)Beams - Basement -1 (The cost of form work included) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum12262.6612262.66143.19FalseNoneNoneFalseNoneFalse1755890.28540
3541675127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Beams b)Basement-2(The cost of form work included) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum12262.6612262.66160.43FalseNoneNoneFalseNoneFalse1967298.54380
3541676127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Beams c) Ground Floor (The cost of form work included) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum12262.6612262.66113.53FalseNoneNoneFalseNoneFalse1392179.78980
3541677127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - For Lintel. a) Basement to Ground (The cost of form work included) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum12262.6612262.6619.0FalseNoneNoneFalseNoneFalse232990.540
3541678127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (The cost of form work included) For Roof Slab. a)Basement-2 ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum11496.2411496.24392.77FalseNoneNoneFalseNoneFalse4515378.18480
3541679127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (The cost of form work included) For Roof Slab.b) Basement-1 ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum11496.2411496.24419.44FalseNoneNoneFalseNoneFalse4821982.90560
3541680127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (The cost of form work included) For Roof Slab c) Ground Floor. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum11496.2411496.24275.09FalseNoneNoneFalseNoneFalse3162500.66160
3541681127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (The cost of form work included). For Roof Slab d)Sump bottom & Top slab ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum11496.2411496.245.25FalseNoneNoneFalseNoneFalse60355.260
3541682127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. For Chejja. c) Ground Floor. (The cost of form work included) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum11113.0311113.037.14FalseNoneNoneFalseNoneFalse79347.03420
3541683127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Staircase a) For BASEMENT-2(The cost of form work included) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum11496.2411496.244.55FalseNoneNoneFalseNoneFalse52307.8920
3541684127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Staircase a) For BASEMENT-1 (The cost of form work included) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum11496.2411496.245.12FalseNoneNoneFalseNoneFalse58860.74880
3541685127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Staircase c) For GROUND(The cost of form work included) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum11496.2411496.249.19FalseNoneNoneFalseNoneFalse105650.44560
3541686127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Staircase d) For First Floor(The cost of form work included) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum11611.2111611.218.9FalseNoneNoneFalseNoneFalse103339.7690
3541687127865None7.18 V-2Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. a)Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum2259.042259.0418.83FalseNoneNoneFalseNoneFalse42537.72320
3541688127865None7.18 V-2Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. b)First floor ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum2281.632281.6318.83FalseNoneNoneFalseNoneFalse42963.09290
3541689127865None15.1 V-2Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating of New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. a) First floor roof slab ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm924.19924.191762.13FalseNoneNoneFalseNoneFalse1628542.92470
3541690127865None15.4 V-2Providing and laying water proofing treatment to the Retaining wall area with PU Elastomeric Single component liquid applied, cold applied,moisture cured high tensile elastomeric PU having elongation of more than 400% and having solid content ofwaterproofing membrane above 90% @ 1.6kg per m2 in 2 coats to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g/ m2. The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm994.56994.561530.15FalseNoneNoneFalseNoneFalse1521825.9840
3541691127865None2.11(a) V-1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/ welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.a) Buildings-Basemnet to Ground Floor ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.t100191.84100191.84332.27FalseNoneNoneFalseNoneFalse33290742.67680
3541692127865None2.11(a) V-1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/ welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.a) Buildings-First floor ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.t101193.76101193.765.64FalseNoneNoneFalseNoneFalse570732.80640
3541693127865None2.5.2 V-1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - a) For Parapet wall ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum11113.0311113.0320.14FalseNoneNoneFalseNoneFalse223816.42420
3541694127865None1.9 V-1Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, c onsolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum297.92297.926412.09FalseNoneNoneFalseNoneFalse1910289.85280
3541695127865None6.32 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - a) basement to ground floor ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm1467.21467.21453.1FalseNoneNoneFalseNoneFalse2131988.320
3541696127865None6.33 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. a) Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm1378.721378.72252.03FalseNoneNoneFalseNoneFalse347478.80160
3541697127865None6.34 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. a) Basemnet To ground. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm1236.481236.48452.94FalseNoneNoneFalseNoneFalse560051.25120
3541698127865None8.5.1 V-2Providing 15 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. a)Basemnet To ground. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm409.92409.924735.39FalseNoneNoneFalseNoneFalse1941131.06880
3541699127865None8.8 V-2Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. -a) basement floor to ground floor ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm415.52415.521807.33FalseNoneNoneFalseNoneFalse750981.76160
3541700127865None8.51 V-2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer incharge. a)Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm112.0112.04735.38FalseNoneNoneFalseNoneFalse530362.560
3541701127865None8.51 V-2Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. a)Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm112.0112.06225.45FalseNoneNoneFalseNoneFalse697250.40
3541702127865None8.2.2 V-2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. a)Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm312.48312.48276.24FalseNoneNoneFalseNoneFalse86319.47520
3541703127865None9.12.3 V-2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 800x800 mm. - a) basement floor to ground floor ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm1407.841407.84968.44FalseNoneNoneFalseNoneFalse1363408.56960
3541704127865None9.19 V-2Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge a) Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm1313.761313.7665.62FalseNoneNoneFalseNoneFalse86208.93120
3541705127865None9.11 V-2Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. a)Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm995.68995.6893.5FalseNoneNoneFalseNoneFalse93096.080
3541706127865None9.24 V-2Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. a)Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm3194.243194.24582.51FalseNoneNoneFalseNoneFalse1860676.74240
3541707127865None9.42.2 Ist Addenda V-2Providing Nosing/Edge finishing to Granite slab using required machinery & labour complete- Full Nosing to Granite Slab of 20mm thick. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m280.0280.0150.0FalseNoneNoneFalseNoneFalse42000.00
3541708127865None9.39 V-2Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. a)Basement To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm1622.881622.88276.24FalseNoneNoneFalseNoneFalse448304.37120
3541709127865None12.15 V-2Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) a)Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm7724.647724.6410.26FalseNoneNoneFalseNoneFalse79254.80640
3541710127865None12.93.1 V-2Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)- Size 62 x 150mm. a) basement to ground floor ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m786.24786.2440.8FalseNoneNoneFalseNoneFalse32078.5920
3541711127865None12.55.1 V-2Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelam a) basement to ground floor ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm2649.922649.9215.12FalseNoneNoneFalseNoneFalse40066.79040
3541712127865None12.13.1 V-2Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. a)Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum110672.8110672.83.18FalseNoneNoneFalseNoneFalse351939.5040
3541713127865None12.51 V-2Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No1137.921137.9231.0FalseNoneNoneFalseNoneFalse35275.520
3541714127865None12.57.4 V-2Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. a) Basemnet To ground -35 mm thick both side Teak ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm5075.845075.8485.07FalseNoneNoneFalseNoneFalse431801.70880
3541715127865None12.90 V-2Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). a) basement floor to ground floor ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm7542.087542.08126.2FalseNoneNoneFalseNoneFalse951810.4960
3541716127865None12.85 V-2Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of minor T&P's shall not be made)all fixtures and separate charges for minor T&P's shall not be made) a)Basement To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm6405.286405.2822.32FalseNoneNoneFalseNoneFalse142965.84960
3541717127865None11.52 V-2Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge a)Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm5288.645288.642.52FalseNoneNoneFalseNoneFalse13327.37280
3541718127865None11.28 V-2Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. a)Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Kg632.8632.8772.2FalseNoneNoneFalseNoneFalse488648.160
3541719127865None11.34B V-2Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. a)Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Kg204.96204.964656.32FalseNoneNoneFalseNoneFalse954359.34720
3541720127865None11.6.1 V-2Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. a)Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm2948.962948.9639.0FalseNoneNoneFalseNoneFalse115009.440
3541721127865None11.3 V-2Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. a)Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm9269.129269.1214.25FalseNoneNoneFalseNoneFalse132084.960
3541722127865None8.39 V-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. a)Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm142.24142.246225.45FalseNoneNoneFalseNoneFalse885508.0080
3541723127865None8.39 V-2Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. a)Basemnet To ground ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm142.24142.244735.38FalseNoneNoneFalseNoneFalse673560.45120
3541724127865None8.30 V-2Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter materials, labour complete as per specifications and as per directionsincluding preparing the surface even and sand paper smooth, cost ofof Engineer-in-charge. a)Ground Floor. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm194.88194.881946.72FalseNoneNoneFalseNoneFalse379376.79360
3541725127865None8.41 V-2Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions materials, labour complete as per specifications and as per directions of Engineer-in-charge. a) Ground Floor. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm187.04187.04148.52FalseNoneNoneFalseNoneFalse27779.18080
3541726127865None9.25 V-2Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. a) Ground Floor. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm896.0896.0845.5FalseNoneNoneFalseNoneFalse757568.00
3541727127865None8.16.2 V-2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m 2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment-Plaster mesh 150mm wide ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m42.5642.56500.0FalseNoneNoneFalseNoneFalse21280.00
3541728127865None6.32 V-2Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - b) First Floor Parapet wall ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm1481.871481.87315.32FalseNoneNoneFalseNoneFalse467263.24840
3541729127865None7.38 V-2Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm642.52642.52102.5FalseNoneNoneFalseNoneFalse65858.30
3541730127865None10.19 V-2Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4(1cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar,labour for all items of work, usage charges of machinery etc., complete as per specification. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm4039.844039.84352.2FalseNoneNoneFalseNoneFalse1422831.6480
17212966740000NoneNoneBuildingsProviding Electrification to Annex court building in Udupi court Premises with Advocates Bhavan & ADR complex in Udupi Dist.8777181.09
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3541731127866None1.2.1Concealed Conduit System: Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.-19/20mm dia 2mm thick ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m73.9273.921300.0FalseNoneNoneFalseNoneFalse96096.00
3541732127866None1.2.2Concealed Conduit System:Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.-25mm dia 2.5 mm thick ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m87.3687.362800.0FalseNoneNoneFalseNoneFalse244608.00
3541733127866None1.2.3Concealed Conduit System:Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary.-32 mm dia 2.5 mm thick ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m115.36115.36800.0FalseNoneNoneFalseNoneFalse92288.00
3541734127866None1.3.1Supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.-19/20mm dia 2mm thick. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m76.1676.16900.0FalseNoneNoneFalseNoneFalse68544.00
3541735127866None1.3.2Supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.-25mm dia 2mm thick ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m88.4888.481200.0FalseNoneNoneFalseNoneFalse106176.00
3541736127866None1.3.3Supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.-32 mm dia 2.5 mm thick ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m110.88110.88300.0FalseNoneNoneFalseNoneFalse33264.00
3541737127866None1.1.1Open Conduit System:Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.-19/20 mm dia 2 mm thick ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m77.2877.28300.0FalseNoneNoneFalseNoneFalse23184.00
3541738127866None1.1.2Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws-25 mm dia 2 mm thick ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m90.7290.72100.0FalseNoneNoneFalseNoneFalse9072.00
3541739127866None1.5.1Supplying and fixing PVC/metal conduit Deep junction box. -19/20 mm deep Junction box. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each54.8854.88600.0FalseNoneNoneFalseNoneFalse32928.00
3541740127866None1.5.2Supplying and fixing PVC/metal conduit Deep junction box.-25 mm deep Junction box. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each62.7262.72700.0FalseNoneNoneFalseNoneFalse43904.00
3541741127866None1.8.1Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required-20 mm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m31.3631.36500.0FalseNoneNoneFalseNoneFalse15680.00
3541742127866None1.8.2Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required-25 mm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m39.239.2500.0FalseNoneNoneFalseNoneFalse19600.00
3541743127866None1.13Supplying And Fixing Metal Fan Box with Round Hook. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No131.04131.04193.0FalseNoneNoneFalseNoneFalse25290.720
3541744127866None2.2.1Wires and Cables-Point wiring using Copper wire without switch.:Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet-Short point upto 3Mtr from tapping point to out let via switch box ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Point301.28301.28200.0FalseNoneNoneFalseNoneFalse60256.00
3541745127866None2.2.2Wires and Cables-Point wiring using Copper wire without switch.:Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet-Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch box ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Point424.48424.48316.0FalseNoneNoneFalseNoneFalse134135.680
3541746127866None2.2.3Wires and Cables-Point wiring using Copper wire without switch.:Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet-Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch box ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Point621.6621.6219.0FalseNoneNoneFalseNoneFalse136130.40
3541747127866None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.-1.5 sqmm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m29.1229.126000.0FalseNoneNoneFalseNoneFalse174720.00
3541748127866None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.-2.5 sqmm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m47.0447.045800.0FalseNoneNoneFalseNoneFalse272832.00
3541749127866None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.-4 sqmm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m70.5670.563600.0FalseNoneNoneFalseNoneFalse254016.00
3541750127866None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments-6 sqmm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m103.04103.042000.0FalseNoneNoneFalseNoneFalse206080.00
3541751127866None3.6.1Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.-6Amps one way Switch ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each114.24114.241135.0FalseNoneNoneFalseNoneFalse129662.40
3541752127866None3.6.2Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293-6Amps Two way Switch ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each185.92185.9216.0FalseNoneNoneFalseNoneFalse2974.720
3541753127866None3.6.3Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293-6Amps 3way socket ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each191.52191.52400.0FalseNoneNoneFalseNoneFalse76608.00
3541754127866None3.6.4Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293-Stepped Fan Regulator Two Module ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each399.84399.84193.0FalseNoneNoneFalseNoneFalse77169.120
3541755127866None3.6.8Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293-6Amps Bell push ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each198.24198.249.0FalseNoneNoneFalseNoneFalse1784.160
3541756127866None3.6.9Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293-32Amps DP switch ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each365.12365.12100.0FalseNoneNoneFalseNoneFalse36512.00
3541757127866None3.6.10Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293 -6/16Amps universal socket ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each264.32264.3280.0FalseNoneNoneFalseNoneFalse21145.60
3541758127866None3.6.11Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293 - TV / Telephone Socket ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each174.72174.724.0FalseNoneNoneFalseNoneFalse698.880
3541759127866None3.6.12Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293 - RJ45 / I.O out let Cat-6 ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each377.44377.44100.0FalseNoneNoneFalseNoneFalse37744.00
3541760127866None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-1-2 Way ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each154.56154.5660.0FalseNoneNoneFalseNoneFalse9273.60
3541761127866None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall -4-5Way. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each198.24198.2450.0FalseNoneNoneFalseNoneFalse9912.00
3541762127866None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall- 6Way ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each246.4246.420.0FalseNoneNoneFalseNoneFalse4928.00
3541763127866None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-8Way ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each292.32292.3240.0FalseNoneNoneFalseNoneFalse11692.80
3541764127866None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-10-12Way ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each357.28357.2850.0FalseNoneNoneFalseNoneFalse17864.00
3541765127866None3.4.8Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall -18 Way ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each453.6453.650.0FalseNoneNoneFalseNoneFalse22680.00
3541766127866None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box -1-2 Module ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each153.44153.4460.0FalseNoneNoneFalseNoneFalse9206.40
3541767127866None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. -4 Module ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each180.32180.3250.0FalseNoneNoneFalseNoneFalse9016.00
3541768127866None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box -6 Module ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each262.08262.0820.0FalseNoneNoneFalseNoneFalse5241.60
3541769127866None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 8 Module ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each318.08318.0840.0FalseNoneNoneFalseNoneFalse12723.20
3541770127866None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 10-12 Module ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each385.28385.2850.0FalseNoneNoneFalseNoneFalse19264.00
3541771127866None3.5.8Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 18 Module ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each511.84511.8450.0FalseNoneNoneFalseNoneFalse25592.00
3541772127866None12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote -Ding Dong Bell ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each275.52275.529.0FalseNoneNoneFalseNoneFalse2479.680
3541773127866None11.3.2Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. - LED light fighting 1 x4'- 20/22 w ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each772.8772.8267.0FalseNoneNoneFalseNoneFalse206337.60
3541774127866None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with . W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition.-LED square or round down light 10-12W ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each991.2991.2200.0FalseNoneNoneFalseNoneFalse198240.00
3541775127866None11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned. -LED Streetlight 40W ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each4506.884506.885.0FalseNoneNoneFalseNoneFalse22534.40
3541776127866None6.2.1Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.-12" Sweep (300 mm) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each3325.283325.288.0FalseNoneNoneFalseNoneFalse26602.240
3541777127866None6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty -48" Sweep 5 Star (1200mm) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each2998.242998.24193.0FalseNoneNoneFalseNoneFalse578660.320
3541778127866None6.5.2Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply.-400 mm Sweep ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each3597.443597.4410.0FalseNoneNoneFalseNoneFalse35974.40
3541779127866None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism -FOUR Pole-100 A 25 kA ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each9505.449505.4416.0FalseNoneNoneFalseNoneFalse152087.040
3541780127866None5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism -FOUR Pole-250 A 36 kA ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each26370.426370.42.0FalseNoneNoneFalseNoneFalse52740.80
3541781127866None5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6-32 Amps DP ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each827.68827.68120.0FalseNoneNoneFalseNoneFalse99321.60
3541782127866None5.18.5Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-40Amps TPN ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each3409.283409.2830.0FalseNoneNoneFalseNoneFalse102278.40
3541783127866None5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 -50-63 A TPN ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each3458.563458.5630.0FalseNoneNoneFalseNoneFalse103756.80
3541784127866None5.19.11Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.-111-Double Door-III - Double Door-4 Way TP & N ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each4522.564522.5626.0FalseNoneNoneFalseNoneFalse117586.560
3541785127866None5.20.10Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board-63 A 4 pole ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each6210.46210.410.0FalseNoneNoneFalseNoneFalse62104.00
3541786127866None5.31Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each4916.84916.82.0FalseNoneNoneFalseNoneFalse9833.60
3541787127866None5.35Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each6389.66389.67.0FalseNoneNoneFalseNoneFalse44727.20
3541788127866None5.34Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each629.44629.4430.0FalseNoneNoneFalseNoneFalse18883.20
3541789127866None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each576.8576.830.0FalseNoneNoneFalseNoneFalse17304.00
3541790127866None8.1Supplying and drawing UTP-CAT 6E LAN cable. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m42.5642.568000.0FalseNoneNoneFalseNoneFalse340480.00
3541791127866None8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.-2Pair ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m23.5223.523000.0FalseNoneNoneFalseNoneFalse70560.00
3541792127866None8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m49.2849.28200.0FalseNoneNoneFalseNoneFalse9856.00
3541793127866None8.4.5Supplying & Fixing of switch mounting rack with power manager & Cable manager.-18U with 650mm depth ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each31803.5231803.5210.0FalseNoneNoneFalseNoneFalse318035.20
3541794127866None8.9.2Supplying fixing of Network Switches.-24 Port Gigabyte (manageable) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each46424.046424.010.0FalseNoneNoneFalseNoneFalse464240.00
3541795127866None8.10.2Supplying & fixing of I/O socket with back box-Double I/O ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each616.0616.080.0FalseNoneNoneFalseNoneFalse49280.00
3541796127866None8.11.2Supplying & Fixing of . ms Cat 6 Patch Cable.-2m ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each287.84287.8480.0FalseNoneNoneFalseNoneFalse23027.20
3541797127866None8.12.1Supplying & Fixing of Patch panel for LAN cabling-48 Port 10/100 patch panel ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each15814.415814.45.0FalseNoneNoneFalseNoneFalse79072.00
3541798127866None11.11.4Supplying & fixing of retrofit type - LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition - 9 W , 6500 K ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each172.48172.4834.0FalseNoneNoneFalseNoneFalse5864.320
3541799127866None2.5.8Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990-3C x 2.5 mm2 ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m126.56126.56100.0FalseNoneNoneFalseNoneFalse12656.00
3541800127866None5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each10432.810432.81.0FalseNoneNoneFalseNoneFalse10432.80
3541801127866None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete-16SWG ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sq CM0.480.48300000.0FalseNoneNoneFalseNoneFalse144000.00
3541802127866None5.40.1Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete,-100Amps 4x30x6mm Aluminium Strips ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m2760.82760.810.0FalseNoneNoneFalseNoneFalse27608.00
3541803127866None5.40.2Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete-250 A 4 x 30 x 10 mm Aluminium Strips ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m3847.23847.210.0FalseNoneNoneFalseNoneFalse38472.00
3541804127866None5.41.2Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint - 50x50x6mm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m442.4442.420.0FalseNoneNoneFalseNoneFalse8848.00
3541805127866None13.2.2Supplying and Fixing.mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires.-Using 32mm dia G.I.Pipe ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each1450.41450.45.0FalseNoneNoneFalseNoneFalse7252.00
3541806127866None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps - On wall / ceiling / Rafter / Girders ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each136.64136.64467.0FalseNoneNoneFalseNoneFalse63810.880
3541807127866None13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each352.8352.8203.0FalseNoneNoneFalseNoneFalse71618.40
3541808127866None13.12Extra length of GI pipe of class B 19mm dia for down rod ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each220.64220.64203.0FalseNoneNoneFalseNoneFalse44789.920
3541809127866None13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each791.84791.8410.0FalseNoneNoneFalseNoneFalse7918.40
3541810127866None10.1.10DIESEL GENERATOR SET: Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have 1.0% Voltage regulation (max) in static conditions- IP: 23 protections with insulation class F&H. - 125 KVA / 100 kw ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Set1017654.41017654.41.0FalseNoneNoneFalseNoneFalse1017654.40
3541811127866None10.2.4Supply, Erection, testing and commissioning of AMF panel suitable for .kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .A 4 pole contactor for alternator with thermal O/L relay,. A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules - 82.5 KVA to 125 KVA ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each122674.72122674.721.0FalseNoneNoneFalseNoneFalse122674.720
3541812127866None32.11Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975 - 50 Sqmm, 3.50Core, (6 GI Strips - 4 x 0.8 mm) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Km200449.76200449.760.2FalseNoneNoneFalseNoneFalse40089.9520
3541813127866None32.18Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975, - 240 Sqmm, 3.5 Core, (30 GI Strips - 4 x 0.8 mm) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Km966185.92966185.920.35FalseNoneNoneFalseNoneFalse338165.0720
3541814127866None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock)in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.-In all kinds of soils. Depth upto 1.50m - Ic, 120 x 0.60 x 0.60 = 43.20 cmt ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum542.08542.0843.2FalseNoneNoneFalseNoneFalse23417.8560
3541815127866None1.10Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications.-In Hard Soil. Ic, 120 x 0.60 x 0.60 = 43.20 cmt ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum179.2179.243.2FalseNoneNoneFalseNoneFalse7741.440
3541816127866None21.01Laying of cable in existing Trench / GI Pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff,-HT Cable-3x95 to 150 Sqmm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Km68680.6468680.640.1FalseNoneNoneFalseNoneFalse6868.0640
3541817127866None21.06Laying of cable in existing Trench / GI Pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff,.-LT Cable-35 to 95 Sqmm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Km34875.6834875.680.2FalseNoneNoneFalseNoneFalse6975.1360
3541818127866None21.07Laying of cable in existing Trench / GI Pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff,.-LT Cable-120 to 240 Sqmm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Km36151.3636151.360.35FalseNoneNoneFalseNoneFalse12652.9760
3541819127866None48.04 GI Pipe B-Class as per IS 1239,.-GI Pipe -40 mm Dia ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Mtr280.0280.050.0FalseNoneNoneFalseNoneFalse14000.00
3541820127866None48.07GI Pipe B-Class as per IS 1239,.-GI Pipe -65 mm Dia ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Mtr519.68519.6830.0FalseNoneNoneFalseNoneFalse15590.40
3541821127866None63.01Supplying of Cable gland - 25 mm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No88.4888.4820.0FalseNoneNoneFalseNoneFalse1769.60
3541822127866None63.04Supplying of Cable gland - 45mm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No220.64220.6412.0FalseNoneNoneFalseNoneFalse2647.680
3541823127866None59.01Supplying of Haevy Duty Copper Terminal Long Barrel,.-25 Sqmm Copper Terminal, Apprx Wt: 11 Gm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No30.2430.2464.0FalseNoneNoneFalseNoneFalse1935.360
3541824127866None59.06Supplying of Haevy Duty Copper Terminal Long Barrel,.- 120 Sqmm Copper Terminal, Apprx Wt: 64 Gm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No156.8156.88.0FalseNoneNoneFalseNoneFalse1254.40
3541825127866None59.10Supplying of Haevy Duty Copper Terminal Long Barrel,.-240 Sqmm Copper Terminal, Apprx Wt: 218 Gm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No397.6397.624.0FalseNoneNoneFalseNoneFalse9542.40
3541826127866None36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975.-95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Km996425.92996425.920.1FalseNoneNoneFalseNoneFalse99642.5920
3541827127866None12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No4766.724766.7210.0FalseNoneNoneFalseNoneFalse47667.20
3541828127866None12.58.2GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m91.8491.84100.0FalseNoneNoneFalseNoneFalse9184.00
3541829127866None12.18Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014.-B. CABLE ENTRY TYPE-250 kVA, Aluminium Wdg, Star 2 (5 Star) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No603759.52603759.521.0FalseNoneNoneFalseNoneFalse603759.520
3541830127866None17.01LT Protection: LT Protection Kit(Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No2265.762265.761.0FalseNoneNoneFalseNoneFalse2265.760
3541831127866None18.02LT Distribution Box as per IS-13947 Part-1&2.-LT Distribution Box for 250 kVA DTC with MCCB's (Sheet Metal)(Dwg No. BESCOM/GM/QS&S/08 Dtd 24.11.2018) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No25551.6825551.681.0FalseNoneNoneFalseNoneFalse25551.680
3541832127866None19.01Lightning Arrester as per IEC-60099-4.-kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR(Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No1030.41030.43.0FalseNoneNoneFalseNoneFalse3091.20
3541833127866None20.01HG Fuse Unit as per IS-5350 Part-2-11 kV, HG Fuse Unit with Solid Core Insulator(Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Set of 3 Nos1197.281197.281.0FalseNoneNoneFalseNoneFalse1197.280
3541834127866None21.05Double Pole TC Set for erection of Transformer on RCC/PSCC 9 Mtr Long Poles as per IS-1977.-For 100/300 kVA 4/5 Star Rated Transformer on PSCC Pole - 9 Mtr Long, 300 Kg WL - MS(Dwg No. BESCOM/GM/QS&S/65 Dtd 24.11.2018. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Set25230.2425230.241.0FalseNoneNoneFalseNoneFalse25230.240
3541835127866None22.09Prefabricated Platform for erection of 250 kVA Transformer on 11 Mtr Spun Pole Structure involving Rectangular hollow Sections 96x48x4.87 Thk and 66x3x4.5 Thk, Circular hollow section of 165.6 OD x 10 Thk , MS Stiffner plate 12 mm Thk, MS plate Base Plate 16 mm Thk, J Blots 12 mm dia, Gusset Plates, Clamps,15 mm rods 2.5 Mtr length as per drawing details. Tor Steel Rods cut of Dia 8 mm,10 mm,12 mm,16 mm and 20 mm bent as per drawing & tied inclusive of labour for Reinforced foundation(Dwg No. BESCOM/GM/QS&S/70 Dtd 24.11.2018 ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Set59492.1659492.161.0FalseNoneNoneFalseNoneFalse59492.160
3541836127866None24.03GOS as per IS-9921, IS-1977-11 kV, 200 Amps Single Break GOS, Vertically Operated ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Set15374.2415374.241.0FalseNoneNoneFalseNoneFalse15374.240
3541837127866None24.06H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - GI. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Set4851.844851.841.0FalseNoneNoneFalseNoneFalse4851.840
3541838127866None25.01DOLO Cutout as per IS-9385, Part-1 to 3-11 kV, DOLO Cutout Conventional to Erstwhile KEB Specification. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Set of 3 Nos6580.06580.01.0FalseNoneNoneFalseNoneFalse6580.00
3541839127866None45.10Heat Shrinkable Indoor Type Cable Termination Kit for PILC Cable.-3x95 Sqmm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Set3514.563514.563.0FalseNoneNoneFalseNoneFalse10543.680
17212966740000NoneNoneBuildingsWater & Sanitory Water Harvesting to Annex court building in Udupi court Premises with Advocates Bhavan & ADR complex in Udupi Dist.2587659.16
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3541840127867None14.44 V-2Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each12570.8812570.886.0FalseNoneNoneFalseNoneFalse75425.280
3541841127867None14.1.1 V-2Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each5470.085470.084.0FalseNoneNoneFalseNoneFalse21880.320
3541842127867None14.4.1 V-2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each4988.484988.488.0FalseNoneNoneFalseNoneFalse39907.840
3541843127867None14.7.2 V-2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each2868.322868.3212.0FalseNoneNoneFalseNoneFalse34419.840
3541844127867None14.22A V-2Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each907.2907.212.0FalseNoneNoneFalseNoneFalse10886.40
3541845127867None14.32.4 V-2Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each1933.121933.1212.0FalseNoneNoneFalseNoneFalse23197.440
3541846127867None14.40.2 V-2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each555.52555.5214.0FalseNoneNoneFalseNoneFalse7777.280
3541847127867None14.33 V-2Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each1014.721014.726.0FalseNoneNoneFalseNoneFalse6088.320
3541848127867None14.34.1 V-2Providing and fixing toilet paper holder : C.P. brass ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each680.96680.9610.0FalseNoneNoneFalseNoneFalse6809.60
3541849127867None14.36.2 V-2Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each104.16104.1612.0FalseNoneNoneFalseNoneFalse1249.920
3541850127867None13.3.2 V-2Providing and fixing brass stop cock of approved quality : 20 mm nominal bore ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each341.6341.622.0FalseNoneNoneFalseNoneFalse7515.20
3541851127867None13.5.3 V-2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each371.84371.848.0FalseNoneNoneFalseNoneFalse2974.720
3541852127867None13.6.1.1 V-2Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each694.4694.48.0FalseNoneNoneFalseNoneFalse5555.20
3541853127867None14.28.2.2 V-2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe. 40 mm dia ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each103.04103.0422.0FalseNoneNoneFalseNoneFalse2266.880
3541854127867None13.58 V-2Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each387.52387.5220.0FalseNoneNoneFalseNoneFalse7750.40
3541855127867None13.4.1 V-2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each614.88614.8815.0FalseNoneNoneFalseNoneFalse9223.20
3541856127867None14.38 V-2Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each162.4162.46.0FalseNoneNoneFalseNoneFalse974.40
3541857127867None13.31.5 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal OD Pipe ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m600.32600.32540.0FalseNoneNoneFalseNoneFalse324172.80
3541858127867None13.31.6 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 50 mm nominal OD Pipe ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m874.72874.72480.0FalseNoneNoneFalseNoneFalse419865.60
3541859127867None13.31.2 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work. 20mm nominal OD Pipe ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m271.04271.04360.0FalseNoneNoneFalseNoneFalse97574.40
3541860127867None13.33.3 V-2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work. 25 mm nominal dia Pipes ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m331.52331.52450.0FalseNoneNoneFalseNoneFalse149184.00
3541861127867None10.1.4 V-5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 63mm dia., 6 kg/sqcm & class 3 From Sink ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m180.32180.3250.0FalseNoneNoneFalseNoneFalse9016.00
3541862127867None10.1.5 V-5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3 Waste Line ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m246.4246.4200.0FalseNoneNoneFalseNoneFalse49280.00
3541863127867None10.1.7 V-5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 Sanitary Line ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m460.32460.32300.0FalseNoneNoneFalseNoneFalse138096.00
3541864127867None10.1.7 V-5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 Rain Water Drainage ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m460.32460.32450.0FalseNoneNoneFalseNoneFalse207144.00
3541865127867None10.1.9 V-5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160mm dia., 6 kg/sqcm & class 3 Rain Water Drainage ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m692.16692.16300.0FalseNoneNoneFalseNoneFalse207648.00
3541866127867None10.1.5 V-5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3 Shaft Drainage ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m246.4246.4150.0FalseNoneNoneFalseNoneFalse36960.00
3541867127867None10.1.7 V-5Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 Shaft Drainage ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m460.32460.32150.0FalseNoneNoneFalseNoneFalse69048.00
3541868127867None16.9 V-5Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each6108.486108.4810.0FalseNoneNoneFalseNoneFalse61084.80
3541869127867None13.34 V-2Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Ltr10.0810.0840000.0FalseNoneNoneFalseNoneFalse403200.00
3541870127867None13.40.3 V-5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 3 HP, size 50x40 Head 30M, Discharge 198 LPM ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each21073.9221073.925.0FalseNoneNoneFalseNoneFalse105369.60
3541871127867None10.8 V-3Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm3123.683123.688.64FalseNoneNoneFalseNoneFalse26988.59520
3541872127867None14.8 V-3Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each1593.761593.7612.0FalseNoneNoneFalseNoneFalse19125.120
17212966740000NoneNoneBuildingsProviding fire fighting system to Annex court building in Udupi court Premises with Advocates Bhavan & ADR complex in Udupi Dist.1910693.12
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3541873127868None15.118.3 V-6Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal bore 4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm Nominal bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal bore 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes-do- Galvanized Iron Pipes 150 mm dia. complete two coats of metal primer and two coats of Red enamel paint etc.-do- ii)Galvanized Iron Pipes 150 mm dia. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Mtr4368.04368.0220.0FalseNoneNoneFalseNoneFalse960960.00
3541874127868None15.118.4 V-6Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal bore 4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm Nominal bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal bore 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes-do- Galvanized Iron Pipes 150 mm dia. complete two coats of metal primer and two coats of Red enamel paint etc.-do- iii)Galvanized Iron Pipes 100 mm dia. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Mtr3192.03192.020.0FalseNoneNoneFalseNoneFalse63840.00
3541875127868None15.118.5 V-6Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal bore 4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84 Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm Nominal bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal bore 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes-do- Galvanized Iron Pipes 150 mm dia. complete two coats of metal primer and two coats of Red enamel paint etc.-do-iv)Galvanized Iron Pipes 80 mm dia. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Mtr2576.02576.015.0FalseNoneNoneFalseNoneFalse38640.00
3541876127868None15.127.2 V-6Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete - etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work - 150mm dia CI butterfly valves (SR 2023-2024 V-6,CHAPTER 15, Page No. 94, Item No. 15.127.2 ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each14000.014000.06.0FalseNoneNoneFalseNoneFalse84000.00
3541877127868None15.127.3 V-6Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete - etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work - 100mm dia CI butterfly valves (SR 2023-2024 V-6,CHAPTER 15, Page No. 94, Item No. 15.127.3 ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each10080.010080.04.0FalseNoneNoneFalseNoneFalse40320.00
3541878127868None15.86 V-6FIRE HYDRANT SYSTEM Supplying Installing, testing and commissioning of 63mm mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve, spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. (SR 2023-2024 V-6,CHAPTER 15, Page No. 89, Item No. 15.86) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each11760.011760.014.0FalseNoneNoneFalseNoneFalse164640.00
3541879127868None15.87 V-6Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. (SR 2023-2024 V-6, CHAPTER 15, Page No. 89, Item No. 15.87) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each5040.05040.014.0FalseNoneNoneFalseNoneFalse70560.00
3541880127868None15.88 V-6Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos .RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. (SR 2023-2024 V-6,CHAPTER 15, Page No. 89, Item No. 15.88) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each5600.05600.014.0FalseNoneNoneFalseNoneFalse78400.00
3541881127868None15.89 V-6Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size 20"x24"x10" complete including cost of materials, labour, usage charges of machinery complete as per specifications. (SR 2023-2024 V-6,CHAPTER 15, Page No. 89, Item No. 15.89) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each7280.07280.014.0FalseNoneNoneFalseNoneFalse101920.00
3541882127868None15.91 V-6Supplying Installing, of M.S. Pressed reel of 600mm Dia swinging type motion which allows a 180 degree swing and conforms to IS 884/85 or Aluminum fitting Single Piece Compact Type. including cost of materials, labour, usage charges of machinery complete as per specifications. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each5824.05824.04.0FalseNoneNoneFalseNoneFalse23296.00
3541883127868None15.92 V-6Supplying Installing, testing and commissioning of 19mm dia 40.0m length hose with rubber lining smooth bore, reinforced of natural/synthetic fibres, a rubber cover finish shall be smooth, fluted or fabric marked with minimum thickness of 1.50mm and to with stand a working pressure of 10Kgf/sqcm confirms & tested as per IS 444/ IS 12585 including cost of materials, labour, usage charges of machinery complete as per specifications. (SR 2023-2024 V-6,CHAPTER 15, Page No. 90, Item No. 15.92) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each6720.06720.04.0FalseNoneNoneFalseNoneFalse26880.00
3541884127868None11.15.3 V-6Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. (SR 2023-2024 V-5, CHAPTER 11, Page No. 89, Item No. 11.15.3) For 25 mm dia GM (Copper alloy) Gate valves ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each1309.281309.284.0FalseNoneNoneFalseNoneFalse5237.120
3541885127868None15.86 V-6Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. Complete (SR 2023-2024 V-6,CHAPTER 15, Page No. 89, Item No. 15.86) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each1680.01680.04.0FalseNoneNoneFalseNoneFalse6720.00
3541886127868None15.8 V-6Providing ABC Powder based MAP 90, 6Kg - Supply, installation in position, testing and commissioning of 6kg Fire Extinguisher Mono Ammonium Phosphate Powder 90, Stored Pressure Type, Pressure Gauge, Gross Weight 9.40 Kg, empty weight 3.4 Kg, Can Height 480MM, Diameter 160MM, Discharge Time less than 13 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,B, C and electrically started Fire, A Rating 3A, B Rating 21B, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete IS 15683 and CE Approved. (SR 2023-2024 V-6,CHAPTER 15, Page No.64, Item No. 15.8) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No2856.02856.030.0FalseNoneNoneFalseNoneFalse85680.00
3541887127868None15.33 V-6Supply and installation of 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall, labour, usage charges of machinery complete as per specifications. complete. (SR 2023-2024 V-6,CHAPTER 15, Page No. 72, Item No. 15.33) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No6160.06160.020.0FalseNoneNoneFalseNoneFalse123200.00
3541888127868None15.34 V-6Supply, installation in position, testing and commissioning of 4.5Kg C0 Gas Type Fire Extinugisher, Trolley Mounted, 2 Easy Weight Management used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuctin : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved 1Year Warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete (SR 2023-2024 V-6,CHAPTER 15, Page No. 72, Item No. 15.34) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No7280.07280.05.0FalseNoneNoneFalseNoneFalse36400.00
17212966740000NoneNoneBuildingsBorewell for Annex court building in Udupi court Premises with Advocates Bhavan & ADR complex in Udupi Dist.416205.44
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3541889127869None12.1.1 V-5Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) (P.No. 139, I.No. 12.1.1, 12.1.2, 12.1.3, 12.1.4 V-5 BWSSB SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m414.4414.450.0FalseNoneNoneFalseNoneFalse20720.00
3541890127869None12.1.2 V-5Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) (P.No. 139, I.No. 12.1.1, 12.1.2, 12.1.3, 12.1.4 V-5 BWSSB SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m519.68519.6850.0FalseNoneNoneFalseNoneFalse25984.00
3541891127869None12.1.3 V-5Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) (P.No. 139, I.No. 12.1.1, 12.1.2, 12.1.3, 12.1.4 V-5 BWSSB SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m552.16552.1650.0FalseNoneNoneFalseNoneFalse27608.00
3541892127869None12.1.4 V-5Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) (P.No. 139, I.No. 12.1.1, 12.1.2, 12.1.3, 12.1.4 V-5 BWSSB SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m640.64640.6450.0FalseNoneNoneFalseNoneFalse32032.00
3541893127869None10.2.1 V-5Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 75mm dia. (P.No. 114, I.No. 10.2.1 V-5 BWSSB SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m243.04243.04200.0FalseNoneNoneFalseNoneFalse48608.00
3541894127869None12.32 V-5Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. (P.No. 143, I.No. 12.32 V-5 BWSSB SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m2164.962164.9650.0FalseNoneNoneFalseNoneFalse108248.00
3541895127869None13.23.3 V-5Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. 6 to 15 HP pumps (P.No. 155, I.No. 13.23.3 V-5 BWSSB SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each17808.017808.01.0FalseNoneNoneFalseNoneFalse17808.00
3541896127869None12.33 V-5Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments (P.No. 143, I.No. 12.33 V-5 BWSSB SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each168.0168.03.0FalseNoneNoneFalseNoneFalse504.00
3541897127869None12.34 V-5Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge (P.No. 143, I.No. 12.34 V-5 BWSSB SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each183.68183.681.0FalseNoneNoneFalseNoneFalse183.680
3541898127869None13.15.7 V-5Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 7.50 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00" (P.No. 152, I.No. 13.15.7 V-5 BWSSB SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each45707.245707.21.0FalseNoneNoneFalseNoneFalse45707.20
3541899127869None13.22.4 V-5Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x6 Sqm. (P.No. 154, I.No. 13.22.4 V-5 BWSSB SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m207.2207.2400.0FalseNoneNoneFalseNoneFalse82880.00
3541900127869None12.4 V-5Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete (P.No. 140 I.No. 12.4 V-5 BWSSB SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each5922.565922.561.0FalseNoneNoneFalseNoneFalse5922.560
17212966740000NoneNoneBuildingsRain water harvesting for annex court building in Udupi court Premises with Advocates Bhavan & ADR complex in Udupi Dist.54958.01
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3541901127870None1.14.1 V-1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In ALL type of Soil ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum114.24114.2417.67FalseNoneNoneFalseNoneFalse2018.62080
3541902127870None17.1 V-2Supplying, filling, spreading & leveling stone boulders of size range 5cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum1122.241122.245.66FalseNoneNoneFalseNoneFalse6351.87840
3541903127870None17.3 V-1Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum1335.041335.045.3FalseNoneNoneFalseNoneFalse7075.7120
3541904127870None2.2.1 V-1Providing and laying in position Cement Concrete for all Foundation works. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum7041.447041.443.07FalseNoneNoneFalseNoneFalse21617.22080
3541905127870NoneAppendix 1 V-1Additionalities for form work, Centring & Scaffolding - Percentage on Finished rate of Concrete per m3 - Foundation, Sub Structure ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum352.07352.073.07FalseNoneNoneFalseNoneFalse1080.85490
3541906127870None2.11 V-1Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/ welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.h) Others (P.18/2.11(a)). ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.t88493.3288493.320.19FalseNoneNoneFalseNoneFalse16813.73080
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17212966770000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17212966770000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17212966770000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17212966770000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17212966770000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17212967480000NoneNoneELIGIBILITYConditional tenders are not acceptedNone
17212967570000NoneNoneELIGIBILITYThe employer reserves the right to reject one and all tenders without assigning any reason there of.None
17212967670000NoneNoneELIGIBILITYThe employer is not responsible for any delay in accessing E- procurement portalNone
17212967770000NoneNoneELIGIBILITYTo qualify for award of this contract, each tenderer should give all details and documents as per Technical and Financial bid attached to this tenderNone
17212967890000NoneNoneELIGIBILITYAs per Karnataka state Government order LD/300/LET/2006 Blore dated 01.01.07 and Government letter no PW/134/BMS/2007 dated 27.07.07, a sum amounting to 1% of the bill amount will be deducted towards constructions labour welfare fundNone
17212967980000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner otherwise it will be rejectedNone
17212968080000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the Executive Engineer reserves the right to verify the documents before approvalNone
17212968240000NoneNoneELIGIBILITYThe tenderer should submit the Registration Certificate along with technical bid.None
17212968390000NoneNoneELIGIBILITYOriginal documents/ Certificates enclosed must be produced in the office of Executive Engineer at the time of opening of technical bid.None
17212968500002NoneNoneELIGIBILITYAll the items in the tender are inclusive of cost and conveyance of all materials, all lead ,lift, loading, unloading, transportation, labour, hire chares of machinery , curing for concrete works, Royalty charges, Work Insurance charge.None
17212968600000NoneNoneELIGIBILITYContractors should follow strictly prevailing rules of labour actNone
17212968720000NoneNoneELIGIBILITYIn case of the death of a contractor, after executing the agreement / commencement of the work, his legal heir, is an eligible registered contractor and is willing, can execute and complete the work, at the accepted tender rates, irrespective of the cost of the work.None
17212968850000NoneNoneELIGIBILITYDepartment will not supply any materialsNone
17212969000001NoneNoneELIGIBILITYThe tenderer should submit proposed methodology and program of construction backed with equipment and material planning, & deployment duly supported with broad calculation and quality management , plan, proposed to be adopted justifying their capability of execution and completion of the work as per technical specifications and within the stipulated period of completion .and shall submit the site layout plan locating stock yard and working site.None
17212969610000NoneNoneELIGIBILITYThe contractor should maintain the work for the period of 2 years (Two years) after the completion of the work at his own costNone
17212969720000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the Standard Bid document KW- IV.None
17212969840001NoneNoneELIGIBILITYPayment of EMD of Rs100000 shall be through E payment and remaining amount through the Bank Guarantee, Bankers Cheque/Demand Draft/Pay Order in favor of Executive Engineer, and shall be valid for 90 days beyond the validity of tender. Original Bank Guarantee shall be submitted to Division Office before Opening of Technical bid .None
17212969980000NoneNoneELIGIBILITYThe tenderer should bear all cost associated with the preparation and submission of his tender and the employer will in no case be resposble and liable for those cost.The cost of the tender form shall not be refundableNone
17212970080000NoneNoneELIGIBILITYTo qualify award of this contract the tenderer should submit proof of work qualification,for having executed similar nature of works,costing not less than 50 % of the value of work.None
17212970170000NoneNoneELIGIBILITYMaterials like Bitumen, steel,cement etc., required for the work shall be procured by the tenderer themselves and should get tested by the quality control authority before used on the work.None
17212970270001NoneNoneELIGIBILITYPERFORMANCE SECURITY The successful tenderer shall furnish Performance Security Deposit (Achievement Guarantee ) at 5% of the contract price plus additional security for unbalanced tender with in 20 days after approve of tender as per rule 25.5 of the tender and clause 44 of the agreement in the form of cash/Bankers Cheque ,D.D,Pay order Bank Guarantee, in the nature of EXECUTIVE ENGINEER,PWD Udupi Division.None
17212970720001NoneNoneELIGIBILITYContractors should be registered with CPWD Or KPWD Class I Registration and the tenderer should submit the Registration Certificate along with technical bid.None
17212971040000NoneNoneELIGIBILITYIncrease in GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delay as determined by the authority while granting the extension of time.None
17212971150000NoneNoneELIGIBILITYAny tender aggrieved by an order passed by the tender accepting authority other than the government under section 13 may appeal through Karnataka Public Procurement Portal only. written appeals will not be accepted.None
17213672450001NoneNoneELIGIBILITYEstimate rates are excluding GST as per Common SR 2024-25 and prevailing GST (18% of Amount Put to tender) amount is kept in form of Lump sum in sanctioned estimate according to guidelines in Common SR (GO:PWD 51 RDF 2019 Bangaluru Dt:18.03.2022). Therefore, amount put to Tender and ECV amount are excluding GST. Hence, GST will be paid separately for S.R Item Only for the quoted amount accordingly. Declaration Certificate must be attached mandatorily.None
17213678470000NoneNoneELIGIBILITYAll Concrete item Rates are inclusive of necessary centering and scaffolding charges. Steel Centering and Steel Scaffolding shall be used for all centering and scaffolding formworks as per specification of Schedule of Rates.None
17218056270000NoneNoneELIGIBILITYThe Successful bidder has to fallow the prevailing Government orders regarding royalty Charges. The contractor has to submit Material Dispatch Permit (MDP) for all naturally available Resources/ Materials along with the running contract bills, otherwise necessary action will be taken as per GO/Circulars.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSection 2: ITT 3.2 To qualify for award of this contract, each Tenderer in its name should have in the last five years b. Satisfactorily completed as prime contractor, at least (i.e.2019-20 to 2023-24):one similar work such as Building construction work of value not less than Rs 676.50 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work-done certificate from not below the rank of Executive Engineer or equivalent
NoneNoneNoneNoneSection 2 ITT 3.2-C: To qualify for award of this contract each tenderer in its name should have in the last five years (2019 20 to 2023-24) executed in any one year the following minimum quantities of work 1.Earth work excavation -19826.00 Cum, 2.PCC/RCC-3180.00 Cum, 3.Steel-271.00 t, 4.SSM/Laterite Stone Masonry/Solid Blocks-1979.00 Sqm,5.Flooring-1871.00 Sqm.Past ExperienceWork-done certificate issued from an officer not below the rank of Executive Engineer or equivalent
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work-done certificate from not below the rank of Executive Engineer or equivalent
NoneNoneNoneNoneSection 2: ITT 3.2 - To qualify for award of this contract, each Tenderer in its name should have in the last five years (i.e. 2019-20 to 2023-24) : (d) The Tenderer or his identified sub-contractor should possess required valid electrical license for executing building electrification works and should have executed similar electrical works totaling Rs.51.80 Lakhs. (usually not less than 50% of the electrical works) in any one year.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach certificate from not below the rank of Executive Engineer or equivalent.
NoneNoneNoneNoneSection 2: ITT 3.2 - To qualify for award of this contract, each Tenderer in its name should have in the last five years (i.e. 2019-20 to 2023-24) : (e) The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works and should have executed similar water supply/sanitary engineering works totaling Rs. 29.40 Lakhs (usually not less than 50% of the water supply/sanitary engineering works) in any one year.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach certificate from not below the rank of Executive Engineer or equivalent.
NoneNoneNoneNoneThe bidder should be a Class-I CPWD / KPWD contractor (With contact number)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach Registration Certificate here
NoneNoneNoneNoneSection 2:ITT.3.3-Each tenderer should further demonstrate: a. Machineries to be owned:1.Machine Concrete mixer-2 No,2.Tipper-3No,3.Water Tanker 5000liters-2 No,4. Excavator- 2 No,5.Centering Materials-5000.00Sqm.Capabilities of VendorPurchase invoice,Bills/Lease/Hire agreement ,R C issued by RTO
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- RC issued by RTO or Sale Deed or Purchase Invoice and Insurance Copy
NoneNoneNoneNoneSection 2:ITT 3.3:Each Tenderer Section 2:ITT 3.3-Each Tenderer should demonstrate: b. Machineries could be on Lease/Hire/Ownership:1. Machine Concrete mixer-2No,2.Excavator-1No, 3.Tipper-3No,4.Water Tanker 5000liters-1 No,5. Generator 10KW Capacity-1 No,6.Self Operating Lift-1No,7.Centering Materials-5000.00Sqm.Capabilities of VendorPurchase invoice,Bills/Lease/Hire agreement ,R C issued by RTO
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- RC issued by RTO or Heir/Lease agreement copy, Sale Deed or Purchase Invoice and Insurance Copy
NoneNoneNoneNoneInformation on works for which Tenders have been submitted and works which are yet to be completed as on the date of this Tender:(B) Works for which Tenders already submitted.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach details in prescribed format in 1.5(B) Section
NoneNoneNoneNoneInformation on works for which Tenders have been submitted and works which are yet to be completed as on the date of this Tender:(A) Existing commitments and on-going works.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach details in prescribed format in 1.5(A) Section-3.
NoneNoneNoneNoneQualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under: Assessed available tender capacity as per Clause 3.6.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach certificate from not below the rank of Executive Engineer or equivalent.
NoneNoneNoneNoneSection 2: ITT 3.3 - Each Tenderer should further demonstrate : (b) Liquid assets and /or availability of credit facilities of not less than Rs. 406.00 Lakhs (Credit lines/ letter of credit/ certificates from banks in prescribed format for meeting the fund requirement etc.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificates from Nationalized banks for meeting the fund requirement Credit Lines/Letter of Credit
NoneNoneNoneNoneSection 2: ITT 3.2 - To qualify for award of this contract, each Tenderer in its name should have in the last five years (i.e.2019-20 to 2023-24) (a) achieved in atleast two financial year, a minimum financial turn over (in all classes of civil engineering construction works only) of Rs 2706.00 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach Turnover Certificate from Registered Chartered Accountant along with profit and loss statement and Balance sheets.
NoneNoneNoneNoneEstimate rates are excluding GST as per Common SR 2023-24 and prevailing GST (18% of Amount Put to tender) amount is kept in form of Lump sum in sanctioned estimate according to guidelines in Common SR (GO:PWD 51 RDF 2019 Bangaluru Dt:18.03.2022). Therefore, amount put to Tender and ECV amount are excluding GST. Hence, GST will be paid separately for the quoted amount accordingly. Declaration Certificate must be attached mandatorily.OthersGST Declaration
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach GST Declaration certificate in prescribed format
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
The bidder should be a Class I CPWD / KPWD contractor With contact numberTrueTechnical Bid
Work CertificatedoneTrueTechnical Bid
Site Layout Plan locating work Site and Stock Yard of Material and Machineries along with PERT chart for 24months working periodTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsUdupiUdupiUdupiUDUPIUdupi court buildingNoneNoneNoneNoneNoneNone
BuildingsUdupiUdupiUdupiUDUPIUdupi Court BuildingNoneNoneNoneNoneNoneNone
BuildingsUdupiUdupiUdupiUDUPIUdupi Court BuildingNoneNoneNoneNoneNoneNone
BuildingsUdupiUdupiUdupiUDUPIUdupi Court BuildingNoneNoneNoneNoneNoneNone
BuildingsUdupiUdupiUdupiUDUPIDistrict court PremisesNoneNoneNoneNoneNoneNone
BuildingsUdupiUdupiUdupiUDUPIDistrict court PremisesNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1721806219000
version0
createdDateNone
modifiedDateNone
blockNumberO/o Executive Engineer,PWD Udupi Division
streetNone
cityUdupi
stateKarnataka
pin576101
tenderRecallDTONone