createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1720679710479
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee630.00
emd50000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose02-08-2024 17:00:00
tenderQueryClose01-08-2024 17:00:00
technicalBidOpenNone
publishedDate26-07-2024 11:47:20
publishedByPostRDPR_EE_DIV_VJN
publishedByUserKPE12111 - J R PAMPAPATHI
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEE OFFICE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9482100616
tenderSupplierListNone
tenderSchedule
createdTs1720679710519
version4
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT6870
titleConstruction Of Class rooms Building to Hampanakatte Ghps School On First Floor at Hampanakatte Village In Hosapete taluk
descriptionConstruction Of Class rooms Building to Hampanakatte Ghps School On First Floor at Hampanakatte Village In Hosapete taluk
categoryWORKS
categoryTextWorks
ecv2500000.00
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location943
locationNameRDPR Division Office Vijayanagara
provisionalAmount2500000.0
groupOverheadTotal386349.95
fileNumberPRED/HPT/AE/KKRDB/MICRO/2021-22/2
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17206797110000NoneNoneBuildingsConstruction Of Class rooms Building to Hampanakatte Ghps School On First Floor at Hampanakatte Village In Hosapete taluk2113650.05
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3506095125443Nonecode01Construction Of Class rooms Building to Hampanakatte Ghps School On First Floor at Hampanakatte Village In Hosapete taluk.First Floor Estimates.Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum8046.618046.617.95FalseNoneNoneFalseNoneFalse63970.54950
3506096125443Nonecode02Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8786.038786.0323.58FalseNoneNoneFalseNoneFalse207174.58740
3506097125443Nonecode03Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum9784.549784.540.45FalseNoneNoneFalseNoneFalse4403.0430
3506098125443Nonecode04Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design cost of material labour usage charges complete as per specifications. (The laps and wastages shall not be measured separatelyKgs95.4595.452990.8FalseNoneNoneFalseNoneFalse285471.860
3506099125443Nonecode05Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum9184.999184.9942.92FalseNoneNoneFalseNoneFalse394219.77080
3506100125443Nonecode06Providing Mathi/nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specificationsCum131716.22131716.220.083FalseNoneNoneFalseNoneFalse10932.446260
3506101125443Nonecode07Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm4287.64287.65.04FalseNoneNoneFalseNoneFalse21609.5040
3506102125443Nonecode08Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKgs178.16178.16181.44FalseNoneNoneFalseNoneFalse32325.35040
3506103125443Nonecode09Providing & fixing of 2.5-track x 2-panel sliding windows made out of multi chambered UPVC Matching to RAL 9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wallthickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made).EtcSqm6947.346947.348.64FalseNoneNoneFalseNoneFalse60025.01760
3506104125443Nonecode10Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm338.04338.04134.52FalseNoneNoneFalseNoneFalse45473.14080
3506105125443Nonecode11Providing 20 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm469.28469.28362.69FalseNoneNoneFalseNoneFalse170203.16320
3506106125443Nonecode12Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs178.16178.16375.0FalseNoneNoneFalseNoneFalse66810.00
3506107125443Nonecode13Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mmSqm1214.271214.27130.5FalseNoneNoneFalseNoneFalse158462.2350
3506108125443Nonecode14Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1536.661536.6633.1FalseNoneNoneFalseNoneFalse50863.4460
3506109125443Nonecode15Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.cm4.244.241200.0FalseNoneNoneFalseNoneFalse5088.00
3506110125443Nonecode16Providing lime wash on walls with one coat with lime of approved quality to give an even shade, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm10.6110.61473.99FalseNoneNoneFalseNoneFalse5029.03390
3506111125443Nonecode17Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm171.8171.8134.52FalseNoneNoneFalseNoneFalse23110.5360
3506112125443Nonecode18Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drop and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm264.71264.71722.75FalseNoneNoneFalseNoneFalse191319.15250
3506113125443Nonecode19Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm177.1177.110.08FalseNoneNoneFalseNoneFalse1785.1680
3506114125443Nonecode20Concealed Conduit System : Supplying 19/20 mm dia 2 mm 2.5 mm thick heavy gauge PVC conduit pipe with suitable size bends metal / PC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18 SWG GI fish wire wherever necessary.Mtr66.066.080.0FalseNoneNoneFalseNoneFalse5280.00
3506115125443Nonecode21Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing caping using copper PVC insulated multi strand 2x1.5Sqmm copper wire with a 6Amps flush type SP control switch shall be fixed on the exisiting plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.Point wiring using class A Materials: for Short point upto 3Mtr from tapping point to out let via switch Item No. 2.1, Page No.5.and as per directed by Engineer Incharge of Work.a. Long point from 6mtr to 10 Mtr from tapping to via switchPoint394.0394.06.0FalseNoneNoneFalseNoneFalse2364.00
3506116125443Nonecode22Wiring for lighting/power circuit using one of PVC insulated 1100v grade multis and Copper conductor single core cable in open or consealed system of wiring as per IS-694:1990 & confirming to GTP of Group-B . Group B Materials and as per directed by Engineer Incharge of Work.c.6 SqmmMtr117.0117.080.0FalseNoneNoneFalseNoneFalse9360.00
3506117125443Nonecode23Supplying Patti type Flourcent tube light fitting of 2' suitable for 14 watts flour cent tube fitting made out of M.S. Sheet and stove enameled with loss open construction copper wound ferromagnetic ballast starter locking type brass contract holders moulded on double fold type sheet base fully wired to use on 230 volts AC supply including T5 lamp. Item No.4.5, Page no.20.and as per directed by Engineer Incharge of Work.Each1269.01269.08.0FalseNoneNoneFalseNoneFalse10152.00
3506118125443Nonecode24Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating andI S: 374/79 and alsocomply with IS: 1709/1984 with latest amendment Rated voltage220V/50 Hz, Rated power input 48W+/-10%,Rated current As per IS:374/79, Rated power factor 0.9l agging (min), Rated speed 350+/-10%RPM, Rated airdelivery 210+/-10% Cubic Meter Minimum, Rated service value 4.2 CMM /W,Three Blade sofblade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation ,210Micro Amp, Power input,W&current, Air Delivery & Fan Speed asperIS:374/1979 with latest amendment, 2year manufacturerWarranty.Each2677.02677.04.0FalseNoneNoneFalseNoneFalse10708.00
3506119125443Nonecode25Supplying and fixing PVC / metal conduit accessories Deep type junction box a) 19/20 mm dia 2 mm thickEach49.049.06.0FalseNoneNoneFalseNoneFalse294.00
3506120125443Nonecode26Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, necessary masonry patch work complete a)12"x12x3" (300x300x76 mm)Each120.0120.06.0FalseNoneNoneFalseNoneFalse720.00
3506121125443Nonecode27Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC conduit / casing caping using copper PVC insulated multi strand 2x1 5 sqmm copper wire with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shaft be terminated with sufficient boose length in a wood / PVC round block complete for each outlet.Each285.0285.05.0FalseNoneNoneFalseNoneFalse1425.00
3506122125443Nonecode28Point wiring using copper wire with switch Supplying and wiring adopting loop system in existing PVC conduit / casing caping using copper PVC insulated multi strand 2x1 5 sqmm copper wire with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shaft be terminated with sufficient boose length in a wood / PVC round block complete for each outlet.b) Medium point upto 3 Mtr from tapping point to outlet via switchEach379.0379.05.0FalseNoneNoneFalseNoneFalse1895.00
3506123125443Nonecode29Supplying and fixing of modular switch / socket / stepped electronic fan regulator dimmer / telephone socket etc on existing modular switch plate.Each102.0102.010.0FalseNoneNoneFalseNoneFalse1020.00
3506124125443Nonecode30Supplying and fixing 3 mm thick hylum plastic sheet etc complete with necessary nitches and screws etc complete.cm0.410.41552.0FalseNoneNoneFalseNoneFalse226.320
3506125125443Nonecode31Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm8776.78776.73.6FalseNoneNoneFalseNoneFalse31596.120
3506126125443Nonecode32Providing and laying in position plain cement concrete for levellingcourse for all works in foundation. The granite/trap/basalt crushedgraded coarse aggregates and fine aggregates laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts,cost ofall materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formworkshall be paid separately)Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarseaggregatesCum6797.76797.77.31FalseNoneNoneFalseNoneFalse49691.1870
3506127125443Nonecode33Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water all materials,usage& all other appurtenaces required to complete the workCum497.7497.7156.0FalseNoneNoneFalseNoneFalse77641.20
3506128125443Nonecode34Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. 3.00 HP - 120 LPM @ 55 m = 5 STG Outlet Dia - 2.00”Each24323.2524323.251.0FalseNoneNoneFalseNoneFalse24323.250
3506129125443Nonecode35Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. HDPE Grade PE80-PN6.0, 63mm diaMtr198.45198.45110.0FalseNoneNoneFalseNoneFalse21829.50
3506130125443Nonecode36Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.1x3x4 m2Mtr173.25173.25125.0FalseNoneNoneFalseNoneFalse21656.250
3506131125443Nonecode37Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter Upto 6 HP pumpsEach10027.510027.51.0FalseNoneNoneFalseNoneFalse10027.50
3506132125443Nonecode38Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the workCum572.25572.2530.6FalseNoneNoneFalseNoneFalse17510.850
3506133125443Nonecode39Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia, 6 kg/sqcm & class 3Mtr50.450.485.0FalseNoneNoneFalseNoneFalse4284.00
3506134125443Nonecode40Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum128.1128.130.6FalseNoneNoneFalseNoneFalse3919.860
3506135125443Nonecode41Providing and Placing on terrace (at all floor levels) polythylene water storage tank IS:12701 Marked with cover and suitable locking arrangements and making neccessary holes for inlet outlet and overflow pipes but without fitting and the base support for tank.Ltr9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17206797110000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17206797110000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17206797110000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17206797110000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17206797110000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17206797110000NoneNoneELIGIBILITYMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)None
17206797110000NoneNoneELIGIBILITYSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)None
17206797110000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17206797110000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17206797110000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17206797110000NoneNoneELIGIBILITYList of existing commitments and ongoing worksNone
17206797110000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17206797110000NoneNoneELIGIBILITYBanker Details for referenceNone
17206797110000NoneNoneELIGIBILITYConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNone
17206797110000NoneNoneELIGIBILITYReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNone
17206797110000NoneNoneELIGIBILITYQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNone
17206797110000NoneNoneELIGIBILITYProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)None
17206797480000NoneNoneELIGIBILITYIf the bidder uploaded the false document while participating in the tender, the bidder will be responsible and action will be initiated as per the tender clause.None
17206797560000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weight of 10per per year to bring them to the price level of the 2023 24 in the Technical Qualification Criteria mentioned in the next sectionNone
17206797650000NoneNoneELIGIBILITYFinancial Year will be reckoned as the period between first day of April and Thirty first day of March of succeeding year (both days inclusive)None
17206797720000NoneNoneELIGIBILITYList of existing commitments and ongoing worksNone
17206797800000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reason.None
17206797880000NoneNoneELIGIBILITYCorrigendum, modifications, correction if any, will be published in the website onlyNone
17206797960000NoneNoneELIGIBILITYDefect liability period will be one yearNone
17206798050000NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e 2019-20 to 2023-24 a. Achieved in at least two financial years a minimum financial turnover in all classes of civil engineering construction works only of Amount Put Tender (Turn over With compulsory UDIN Number)None
17206798120000NoneNoneELIGIBILITYTo qualify for award of this contract, each Tenderer in his name should have in the last five years i.e 2019-20 to 2023-24 b. Satisfactorily completed, as prime contractor, at least one similar work (Checkdam) of value not less than 50% of the amount put tender (Workdone with indent No)None
17206798290000NoneNoneELIGIBILITYIf the tenderer has quoted below the schedule-B amount the difference amount should be paid in the form of F.D.R or D.D (As per G.O) in the name of Executive Engineer, PRE Division, Vijayanagara Hosapete from Nationalized Bank only and upload the scanned copy of the same in e-portal at the time of applying the tender The Same Scanned copy for Different work will be liable for RejectionNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Valid PWD Registration copyTrueTechnical Bid
Last 5 years Audit Report with UDIN NoTrueTechnical Bid
Similar Nature Work done certificate with eproc Indent NoTrueTechnical Bid
Ongoing commitments and other KW DocumentsTrueTechnical Bid
Difference Amount DD or FDR Scanned copyTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsVijayanagaraHosapeteBellaryHOSPETHampanakatte VillageNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone