| 3625254 | 131750 | None | code01 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge | Cum | 1663.0 | 1663.0 | 10.03 | False | None | None | False | None | False | 16679.89 | 0 |
| 3625255 | 131750 | None | code02 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the
appropriate disposal area as per direction of Engineer-in-charge.& with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 1029.0 | 1029.0 | 3.37 | False | None | None | False | None | False | 3467.73 | 0 |
| 3625256 | 131750 | None | code03 | 19.55 Dismantling old plaster or skirting raking out joints and cleaning the
surface for plaster including disposal of rubbish to the dumping ground
to the appropriate disposal area as per direction of Engineer-in-charge.& with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 37.0 | 37.0 | 19.44 | False | None | None | False | None | False | 719.28 | 0 |
| 3625257 | 131750 | None | code04 | Earth work in surface excavation by manual means for lowering & levelling
the ground by chiselling and wedging in Hard rock for all works other than
foundation & depth not exceeding 100 mm as per drawing and technical
specifications, including setting out, barricading, caution lights, dressing of
excavated surfaces, disposing off the excavated spalls/stuff & stacking the
selected spall/ stuff for reuse in a radius of 50 m and lift upto 1.5 m including
cost of labour, tools, usage & other appurtenances required to complete the
work& with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 177.0 | 177.0 | 13.75 | False | None | None | False | None | False | 2433.75 | 0 |
| 3625258 | 131750 | None | code05 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work. | Cum | 242.0 | 242.0 | 11.16 | False | None | None | False | None | False | 2700.72 | 0 |
| 3625259 | 131750 | None | code06 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregates& with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 5664.0 | 5664.0 | 5.84 | False | None | None | False | None | False | 33077.76 | 0 |
| 3625260 | 131750 | None | code07 | Providing and Constructing Laterite size stone Masonry including Cost and Conveince of all metirials curing etc Complete as specification IS 3620/1979 having compressive strenght not less than 3.5 N/MM Sqm for Satulated Dry Samples - For Foundation In CM 1:6 & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 6374.0 | 6374.0 | 8.21 | False | None | None | False | None | False | 52330.54 | 0 |
| 3625261 | 131750 | None | code08 | Providing and Constructing Laterite size stone Masonry including Cost and Conveince of all metirials curing etc Complete as specification IS 3620/1979 having compressive strenght not less than 3.5 N/MM Sqm for Satulated Dry Samples - For Basement In CM 1:6& with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 6448.0 | 6448.0 | 2.98 | False | None | None | False | None | False | 19215.04 | 0 |
| 3625262 | 131750 | None | code09 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works ofbridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates& with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 6336.0 | 6336.0 | 1.49 | False | None | None | False | None | False | 9440.64 | 0 |
| 3625263 | 131750 | None | code10 | Add Centring Charges for Plinth Beams& with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 3168.0 | 3168.0 | 1.49 | False | None | None | False | None | False | 4720.32 | 0 |
| 3625264 | 131750 | None | code11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.& with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 204.0 | 204.0 | 11.16 | False | None | None | False | None | False | 2276.64 | 0 |
| 3625265 | 131750 | None | code12 | Providing Brick work with clay flyash Non Modular brick of classdesignation 3.5 in superstructure above plinth level up to floor I level in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.& with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 8080.0 | 8080.0 | 10.97 | False | None | None | False | None | False | 88637.6 | 0 |
| 3625266 | 131750 | None | code13 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work& with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 1060.0 | 1060.0 | 7.44 | False | None | None | False | None | False | 7886.4 | 0 |
| 3625267 | 131750 | None | code14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates& with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 6323.0 | 6323.0 | 0.57 | False | None | None | False | None | False | 3604.11 | 0 |
| 3625268 | 131750 | None | code15 | Add Centring Charges for Lintel& with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 3793.8 | 3793.8 | 0.57 | False | None | None | False | None | False | 2162.466 | 0 |
| 3625269 | 131750 | None | code16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 6843.0 | 6843.0 | 13.31 | False | None | None | False | None | False | 91080.33 | 0 |
| 3625270 | 131750 | None | code17 | Add Centring Charges for Beems & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 3421.5 | 3421.5 | 3.18 | False | None | None | False | None | False | 10880.37 | 0 |
| 3625271 | 131750 | None | code18 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (Thelaps and wastages shall not be measured separately& with all lead and lift. and as per direction of the Engineer in charge of work. | t | 89457.0 | 89457.0 | 0.55 | False | None | None | False | None | False | 49201.35 | 0 |
| 3625272 | 131750 | None | code19 | Supplying and fixing rolling shutters of approved make, made of required
size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 2633.0 | 2633.0 | 8.1 | False | None | None | False | None | False | 21327.3 | 0 |
| 3625273 | 131750 | None | code20 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge& with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 295.0 | 295.0 | 226.6 | False | None | None | False | None | False | 66847.0 | 0 |
| 3625274 | 131750 | None | code21 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 312.0 | 312.0 | 44.43 | False | None | None | False | None | False | 13862.16 | 0 |
| 3625275 | 131750 | None | code22 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 323.0 | 323.0 | 13.8 | False | None | None | False | None | False | 4457.4 | 0 |
| 3625276 | 131750 | None | code23 | KSRB15-7 : Providing lime rendering for plastering to wall and ceiling, including cost of materials, labour, curing complete as per specifications.& with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 32.0 | 32.0 | 58.23 | False | None | None | False | None | False | 1863.36 | 0 |
| 3625277 | 131750 | None | code24 | 9.12 Providing and laying vitrified floor tiles with thickness 9-10 mm in
different sizes with water absorption less than 0.08% and conforming to
IS: 15622, of approved make, in all colours and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement
slurry @ 3.3 kg/ m2 including grouting the joints with white cement and
matching pigments etc., complete.9.12.2 Size of Tile 600x600 mm& with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 1145.0 | 1145.0 | 8.58 | False | None | None | False | None | False | 9824.1 | 0 |
| 3625278 | 131750 | None | code25 | 9.2 Providing and laying 52 mm thick cement concrete flooring with concrete
hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 L per 50 kg of cement or as per direction of Engineer incharge & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 800.0 | 800.0 | 13.8 | False | None | None | False | None | False | 11040.0 | 0 |
| 3625279 | 131750 | None | code26 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid& with all lead and lift. and as per direction of the Engineer in charge of work. | No | 5977.0 | 5977.0 | 1.0 | False | None | None | False | None | False | 5977.0 | 0 |
| 3625280 | 131750 | None | code27 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal sibility for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 1S mm nominal 25dia Pipes& with all lead and lift. and as per direction of the Engineer in charge of work. | Mtr | 318.0 | 318.0 | 13.0 | False | None | None | False | None | False | 4134.0 | 0 |
| 3625281 | 131750 | None | code28 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.& with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 53.0 | 53.0 | 72.45 | False | None | None | False | None | False | 3839.85 | 0 |
| 3625282 | 131750 | None | code29 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.& with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 89.0 | 89.0 | 72.45 | False | None | None | False | None | False | 6448.05 | 0 |
| 3625283 | 131750 | None | code30 | 8.25 Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly
brooming the surface to remove all dirt, dust, mortar drops and foreign
matter including preparing the surface even and sand paper smooth, cost
of materials, labour complete as per specifications and as per directions
of Engineer-in-charge. | Sqm | 137.0 | 137.0 | 129.72 | False | None | None | False | None | False | 17771.64 | 0 |
| 3625284 | 131750 | None | code31 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 8276.0 | 8276.0 | 2.88 | False | None | None | False | None | False | 23834.88 | 0 |
| 3625285 | 131750 | None | code32 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 167.0 | 167.0 | 56.5 | False | None | None | False | None | False | 9435.5 | 0 |
| 3625286 | 131750 | None | code33 | 12.90 Providing & fixing of 3track x 2panel sliding windows made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum
TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer)
and lead free gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 108mm width 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm 75mm with GI reinforcement of 2mm and mesh sash of size 37mm 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware Multi point locking system with touch lock. Wall thickn ss of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P s shall not be made) | Sqm | 6551.0 | 6551.0 | 2.76 | False | None | None | False | None | False | 18080.76 | 0 |
| 3625287 | 131750 | None | code34 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter | No | 291.0 | 291.0 | 12.0 | False | None | None | False | None | False | 3492.0 | 0 |
| 3625288 | 131750 | None | code35 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 g/m2 (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having
lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered
and square edges of the board with recommended jointing compound, jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with
frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS Certification marks only) Common SR Volume (1) (P-25,It No 7.32.1 ) 2023-24 | No | 983.0 | 983.0 | 12.6 | False | None | None | False | None | False | 12385.8 | 0 |
| 3625289 | 131750 | None | code36 | Kacheri Chairs
PU handle I pipe with Powder Coated good quality bushes inside sheet back spring and absolutly with fabric & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 6500.0 | 6500.0 | 6.0 | False | None | None | False | None | False | 39000.0 | 0 |
| 3625290 | 131750 | None | code37 | Table
1'' Square tube 18 guage frame construction and two no's lockers instead one side and wooden top instead & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 8000.0 | 8000.0 | 2.0 | False | None | None | False | None | False | 16000.0 | 0 |
| 3625291 | 131750 | None | code38 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with whitecement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, completeas per specifications.& with all lead and lift. and as per direction of the Engineer in charge of work.) | Sqm | 1449.0 | 1449.0 | 6.3 | False | None | None | False | None | False | 9128.7 | 0 |
| 3625292 | 131750 | None | code39 | Supplying ......TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper
cable and a battery operated wireless remote unit 6.7.2 1.5 Ton capacity& with all lead and lift. and as per direction of the Engineer in charge of work.) | No | 47683.0 | 47683.0 | 1.0 | False | None | None | False | None | False | 47683.0 | 0 |
| 3625293 | 131750 | None | code40 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be
terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch& with all lead and lift. and as per direction of the Engineer in charge of work.) | Sqm | 276.0 | 276.0 | 2.0 | False | None | None | False | None | False | 552.0 | 0 |
| 3625294 | 131750 | None | code41 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be
terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let
via switch& with all lead and lift. and as per direction of the Engineer in charge of work.) | Sqm | 386.0 | 386.0 | 1.0 | False | None | None | False | None | False | 386.0 | 0 |
| 3625295 | 131750 | None | code42 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be
terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via
switch& with all lead and lift. and as per direction of the Engineer in charge of work.) | Sqm | 567.0 | 567.0 | 2.0 | False | None | None | False | None | False | 1134.0 | 0 |
| 3625296 | 131750 | None | code43 | Concelaed conduit System Supplying heavy gauge PVC Conduit pipe 19/20mm dia2mm thick confirming To IS 2509 with suitable size bends, metal/PVC junction boxes boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered PVC end enclosers, run with 18SWG GI fish wire wherever neccesary 19/20mm dia 2mm thick& with all lead and lift. and as per direction of the Engineer in charge of work.) | Mtr | 61.0 | 61.0 | 60.0 | False | None | None | False | None | False | 3660.0 | 0 |
| 3625297 | 131750 | None | code44 | Supplying and flush mounting teak wood box without front plank, made of not less than 12mm thick wood, after due grove cutting, finishing with necessary cement plastering complete & with all lead and lift. and as per direction of the Engineer in charge of work.) | Mtr | 101.0 | 101.0 | 1.0 | False | None | None | False | None | False | 101.0 | 0 |
| 3625298 | 131750 | None | code45 | Supplying and fixing regular M.C.B. distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts with provision for fixing suitable type capacity MCB’s single phase/3phase/single door with powder coated painting made out of 14SWGM.S enclosure & with all lead and lift. and as per direction of the Engineer in charge of work.) | No | 777.0 | 777.0 | 1.0 | False | None | None | False | None | False | 777.0 | 0 |
| 3625299 | 131750 | None | code46 | Supplying of 2 feet - LED PVC Square Batten W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50Hz & Power factor 0.9 along with CE approved. 5 years Warranty against any manufacturing defect working under standard electrical condition ( 25 /4.29) LED light fighting 2 - 14 watts& with all lead and lift. and as per direction of the Engineer in charge of work.) | No | 740.0 | 740.0 | 1.0 | False | None | None | False | None | False | 740.0 | 0 |
| 3625300 | 131750 | None | code47 | Wiring for lighting/ power circuit using one FRLS P.V.C.insulated 1100v.grade multistrand Copper with low conducror resistance single core wire in open or concealed system of wiring with specified IS 694 :1990 &confirming to the attached GTP of GROUP-A2.5 sq mm & with all lead and lift. and as per direction of the Engineer in charge of work.) | Mtr | 40.0 | 40.0 | 120.0 | False | None | None | False | None | False | 4800.0 | 0 |
| 3625301 | 131750 | None | code48 | Wiring for lighting/ power circuit using one FRLS P.V.C.insulated 1100v.grade multistrand Copper with low conducror resistance single core wire in open or concealed system of wiring with specified IS 694 :1990 &confirming to the attached GTP of GROUP-A4. sq mm& with all lead and lift. and as per direction of the Engineer in charge of work.) | Mtr | 59.0 | 59.0 | 30.0 | False | None | None | False | None | False | 1770.0 | 0 |
| 3625302 | 131750 | None | code49 | Supplying 6A flush type socket and 6amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box wiring using necessary capacity wires as required as per IS 1293 and IS 3654 & with all lead and lift. and as per direction of the Engineer in charge of work.) | No | 121.0 | 121.0 | 12.0 | False | None | None | False | None | False | 1452.0 | 0 |
| 3625303 | 131750 | None | code50 | Supplying and fixing of moudular switch/ socket/ steped electronic fan regulator/ dimmer / telephone socket etc., an existing modular switch plate as per IS 3854 and IS 12936A 1way DP switch & with all lead and lift. and as per direction of the Engineer in charge of work.) | No | 88.0 | 88.0 | 1.0 | False | None | None | False | None | False | 88.0 | 0 |
| 3625304 | 131750 | None | code51 | Fixing all types and all capacities of fluorescent/false ceiling/ spot light/ CFL/ LED fittings indoor on the wall/ceiling rafter/girders using 23/0.0076” twin twisted pvc insulated wires, required no.s of round blocks& clamps (if require & with all lead and lift. and as per direction of the Engineer in charge of work.) | No | 119.0 | 119.0 | 4.0 | False | None | None | False | None | False | 476.0 | 0 |