createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721912908193
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd3210000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose23-08-2024 16:00:00
tenderQueryClose08-08-2024 11:00:00
technicalBidOpen26-08-2024 11:00:00
publishedDate25-07-2024 19:03:15
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate09-08-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonGnanesh Kumar V P
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9449843360
tenderSupplierListNone
tenderSchedule
createdTs1721912908226
version5
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT547
titleConstruction of 100 Bedded Taluk Level Hospital at Nelamangala in Bengaluru Rural District.
descriptionConstruction of 100 Bedded Taluk Level Hospital at Nelamangala in Bengaluru Rural District.
categoryWORKS
categoryTextWorks
ecv320840685.53
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount371500000.0
groupOverheadTotal0.0
fileNumberHFWD/BNG/SD/2024-25/TLH(Nelamangala)
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17219129080000NoneNoneBuildingsProposed Construction of 100 Bedded Taluk Level Hospital at, Nelamangala in Bengaluru Rural District.320840685.53
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3622680131621NoneV-3,2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle GROUND FLOOR ---- etc., complete with all lead Sqm477.65477.65107.2FalseNoneNoneFalseNoneFalse51204.080
3622681131621NoneV-1,1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.GROUND FLOOR ---- etc., complete with all lead Cum115.46115.468368.75FalseNoneNoneFalseNoneFalse966255.8750
3622682131621NoneV-1,1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m.GROUND FLOOR ---- etc., complete with all lead Cum123.97123.979638.9FalseNoneNoneFalseNoneFalse1194934.4330
3622683131621NoneV-1,1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depthGROUND FLOOR ---- etc., complete with all lead Cum441.19441.191951.9FalseNoneNoneFalseNoneFalse861158.7610
3622684131621NoneV-1,1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 mGROUND FLOOR ---- etc., complete with all lead Cum516.55516.55157.6FalseNoneNoneFalseNoneFalse81408.280
3622685131621NoneV-1,1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. In Hard Rock requiring blasting Depth upto 1.50mGROUND FLOOR ---- etc., complete with all lead Cum673.33673.332097.57FalseNoneNoneFalseNoneFalse1412356.80810
3622686131621NoneV-1,1.16.2Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. Depth exceeding 1.5 m, but not exceeding 3 mGROUND FLOOR ---- etc., complete with all lead Cum757.19757.19412.16FalseNoneNoneFalseNoneFalse312083.43040
3622687131621NoneV-3,1.1ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum.GROUND FLOOR ---- etc., complete with all lead Cum164.08164.089140.1FalseNoneNoneFalseNoneFalse1499707.6080
3622688131621NoneV-2,4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. at 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.GROUND FLOOR ---- etc., complete with all lead Sqm143.42143.423971.6FalseNoneNoneFalseNoneFalse569606.8720
3622689131621NoneV-1,1.9Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.GROUND FLOOR ---- etc., complete with all lead Cum323.3323.36128.8FalseNoneNoneFalseNoneFalse1981441.040
3622690131621NoneV-1,1.8Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.GROUND FLOOR ---- etc., complete with all lead Cum576.1576.18292.5FalseNoneNoneFalseNoneFalse4777309.250
3622691131621NoneV-1,2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWorkGROUND FLOOR ---- etc., complete with all lead Cum7279.037279.03834.4FalseNoneNoneFalseNoneFalse6073622.6320
3622692131621NoneV-1,2.2.3FOOTINGS-Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork.GROUND FLOOR ---- etc., complete with all lead Cum8316.848316.84686.29FalseNoneNoneFalseNoneFalse5707764.12360
3622693131621NoneV-1,2.2.3PEDESTALS-Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork.GROUND FLOOR ---- etc., complete with all lead Cum8470.858470.8559.29FalseNoneNoneFalseNoneFalse502236.69650
3622694131621NoneV-1,2.5.2COLUMNS & LIFT WALL-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.GROUND FLOOR ---- etc., complete with all lead Cum14138.8714138.87317.49FalseNoneNoneFalseNoneFalse4488949.83630
3622695131621NoneV-1,2.5.2PLINTH BEAM & RCC SLAB & STAIRCASE-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.GROUND FLOOR ---- etc., complete with all lead Cum12475.4712475.471002.69FalseNoneNoneFalseNoneFalse12509029.01430
3622696131621NoneV-1,2.5.2RCC BEAMS & LINTEL--Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.GROUND FLOOR ---- etc., complete with all lead Cum13307.1713307.17370.6FalseNoneNoneFalseNoneFalse4931637.2020
3622697131621NoneV-1,2.5.1CILL-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.GROUND FLOOR ---- etc., complete with all lead Cum11684.2511684.2540.3FalseNoneNoneFalseNoneFalse470875.2750
3622698131621NoneV-2,8.16 aProviding lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.GROUND FLOOR ---- etc., complete with all lead Sqm1504.671504.6761.9FalseNoneNoneFalseNoneFalse93139.0730
3622699131621NoneV-1,2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.GROUND FLOOR ---- etc., complete with all lead Tonne108726.04108726.04304.4FalseNoneNoneFalseNoneFalse33096206.5760
3622700131621NoneV-2,5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 1 cement : 6 coarse sandGROUND FLOOR ---- etc., complete with all lead Cum7765.197765.19103.4FalseNoneNoneFalseNoneFalse802920.6460
3622701131621NoneV-2,6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 Part - I - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.GROUND FLOOR ---- etc., complete with all lead Sqm1592.171592.174879.6FalseNoneNoneFalseNoneFalse7769152.7320
3622702131621NoneV-2,6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 Part - I - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.GROUND FLOOR ---- etc., complete with all lead Sqm1341.81341.8356.1FalseNoneNoneFalseNoneFalse477814.980
3622703131621NoneV-2,12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications.GROUND FLOOR ---- etc., complete with all lead Cum120099.75120099.757.4FalseNoneNoneFalseNoneFalse888738.150
3622704131621NoneV-2,12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.GROUND FLOOR ---- etc., complete with all lead Nos1234.851234.8585.0FalseNoneNoneFalseNoneFalse104962.250
3622705131621NoneV-2,22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mmGROUND FLOOR ---- etc., complete with all lead No668.47668.47170.0FalseNoneNoneFalseNoneFalse113639.90
3622706131621NoneV-2,22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mmGROUND FLOOR ---- etc., complete with all lead No455.78455.7885.0FalseNoneNoneFalseNoneFalse38741.30
3622707131621NoneV-2,22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mmGROUND FLOOR ---- etc., complete with all lead No182.31182.31125.0FalseNoneNoneFalseNoneFalse22788.750
3622708131621NoneV-2,22.15.9Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mmGROUND FLOOR ---- etc., complete with all lead No85.0885.08280.0FalseNoneNoneFalseNoneFalse23822.40
3622709131621NoneV-2,22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mmGROUND FLOOR ---- etc., complete with all lead No121.54121.5485.0FalseNoneNoneFalseNoneFalse10330.90
3622710131621NoneV-2,12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.GROUND FLOOR ---- etc., complete with all lead No1278.61278.685.0FalseNoneNoneFalseNoneFalse108681.00
3622711131621NoneV-2,10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOOR ---- etc., complete with all lead Nos72.9272.92510.0FalseNoneNoneFalseNoneFalse37189.20
3622712131621NoneV-2,20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOOR ---- etc., complete with all lead Rmtr63.263.2581.2FalseNoneNoneFalseNoneFalse36731.840
3622713131621NoneV-2,12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 part-I 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side CommercialGROUND FLOOR ---- etc., complete with all lead Sqm4037.564037.56242.4FalseNoneNoneFalseNoneFalse978704.5440
3622714131621NoneV-2,12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVCMatching to RAL-9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be madeGROUND FLOOR ---- etc., complete with all lead Sqm8184.58184.5221.7FalseNoneNoneFalseNoneFalse1814503.650
3622715131621NoneV-2,12.85Providing & fixing of louvered ventilator made out of multi chambered UPVCMatching to RAL-9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made GROUND FLOOR ---- etc., complete with all lead Sqm6950.876950.8722.0FalseNoneNoneFalseNoneFalse152919.140
3622716131621NoneV-2,11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOOR ---- etc., complete with all lead Kg204.19204.195295.2FalseNoneNoneFalseNoneFalse1081226.8880
3622717131621NoneV-2,12.93.1Providing and fixing factory made single extruded WPC Wood Polymer Composite solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 Suspension Grade, calcium carbonate and natural fibres wood powder/rice husk/ wheat husk and non toxic additives maximum toxicity index of 12 for 100 g fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N Face & 1100 N Edge, minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. Fixtures shall be paid for separatelySize 62 x 100mmGROUND FLOOR ---- etc., complete with all lead m853.21853.21218.4FalseNoneNoneFalseNoneFalse186341.0640
3622718131621NoneV-2,12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC Wood PolymerComposite solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 Suspension Grade, calcium carbonate and natural fibers wood powder/rice husk/wheat husk and non toxic additives maximum toxicity index of 12 for 100 g having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N Face & 900 N Edge, minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.Cost of Fixtures to be paid separately30 mm thicknessGROUND FLOOR ---- etc., complete with all lead Sqm4235.674235.6770.1FalseNoneNoneFalseNoneFalse296920.4670
3622719131621NoneV-2,12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm, with necessary accessories and screws etc. complete.GROUND FLOOR ---- etc., complete with all lead Nos1353.961353.9686.0FalseNoneNoneFalseNoneFalse116440.560
3622720131621NoneV-2,11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.GROUND FLOOR ---- etc., complete with all lead Kgs165.29165.29241.92FalseNoneNoneFalseNoneFalse39986.95680
3622721131621NoneV-2,11.35.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. Glazing, paneling and dash fasteners to be paid for separately :For Fixed Portion : Anodised aluminium anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15 including cost of materials, labour, usage charges of machinery complete as per specifications.GROUND FLOOR ---- etc., complete with all lead Kg549.36549.36242.8FalseNoneNoneFalseNoneFalse133384.6080
3622722131621NoneV-2,11.37.1Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . Cost of aluminium snap beading shall be paid in basic item:With float glass panes of 4.0 mm thickness weight not less than 10kg/ Sqm including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.GROUND FLOOR ---- etc., complete with all lead Sqm1200.821200.8219.6FalseNoneNoneFalseNoneFalse23536.0720
3622723131621NoneV-2,8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... InsideGROUND FLOOR ---- etc., complete with all lead Sqm379.2379.26902.6FalseNoneNoneFalseNoneFalse2617465.920
3622724131621NoneV-2,8.1Providing 6 mm cement plaster with cement mortar 1:3 1 cement : 3 fine sand on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc., complete with all lead Sqm256.45256.455929.5FalseNoneNoneFalseNoneFalse1520620.2750
3622725131621NoneV-2,8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.GROUND FLOOR ---- etc., complete with all lead Sqm121.54121.5412832.17FalseNoneNoneFalseNoneFalse1559621.94180
3622726131621NoneV-2,8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. OutsideGROUND FLOOR ---- etc., complete with all lead Sqm424.17424.171799.9FalseNoneNoneFalseNoneFalse763463.5830
3622727131621NoneV-2,8.3.1Providing 20 mm cement plaster of mix :1:4 1 cement: 4 fine sand to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.GROUND FLOOR ---- etc., complete with all lead Sqm430.25430.25914.9FalseNoneNoneFalseNoneFalse393635.7250
3622728131621NoneV-2,8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment.Plaster mesh 150mm wideGROUND FLOOR ---- etc., complete with all lead Rmtr46.1946.199382.9FalseNoneNoneFalseNoneFalse433396.1510
3622729131621NoneV-2,8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.GROUND FLOOR ---- etc., complete with all lead Rmtr63.263.22650.0FalseNoneNoneFalseNoneFalse167480.00
3622730131621NoneV-2,9.17.2Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 1 cement: 3 coarse sand, jointing with grey cement slurry at 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mmGROUND FLOOR ---- etc., complete with all lead Sqm1428.11428.12395.03FalseNoneNoneFalseNoneFalse3420342.3430
3622731131621NoneV-2,9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 1 ce- ment : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size and top layer 12 mm thick cement hardener consisting of mix 1:2 1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size by volume, hardening compound mixed at 2 L per 50 kg of cement or as per direction of Engineer incharge.GROUND FLOOR ---- etc., complete with all lead Sqm972.32972.32202.21FalseNoneNoneFalseNoneFalse196612.82720
3622732131621NoneV-2,9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS : 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.Size of Tile 600x600 mmGROUND FLOOR ---- etc., complete with all lead Sqm1611.621611.62843.53FalseNoneNoneFalseNoneFalse1359449.81860
3622733131621NoneV-2,8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 1 cement: 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc., complete with all lead Sqm358.54358.541496.7FalseNoneNoneFalseNoneFalse536626.8180
3622734131621NoneV-2,9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 1:4 1 cement : 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.GROUND FLOOR ---- etc., complete with all lead Sqm3466.323466.321296.04FalseNoneNoneFalseNoneFalse4492489.37280
3622735131621NoneV-2,10.18Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 1 cement : 3 coarse sand proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete.GROUND FLOOR ---- etc., complete with all lead Sqm4082.534082.53100.65FalseNoneNoneFalseNoneFalse410906.64450
3622736131621NoneV-2,9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR ---- etc., complete with all lead Sqm6475.656475.65234.9FalseNoneNoneFalseNoneFalse1521130.1850
3622737131621NoneV-2,9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm average thick base of cement mortar 1:4 1 cement : 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.GROUND FLOOR ---- etc., complete with all lead Sqm3138.163138.16183.5FalseNoneNoneFalseNoneFalse575852.360
3622738131621NoneV-2,40180Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 1 cement : 4 coarse sand, joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2GROUND FLOOR ---- etc., complete with all lead Sqm4785.034785.03112.35FalseNoneNoneFalseNoneFalse537598.12050
3622739131621NoneV-2,15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed at 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix at 0.5 kg/bag of cement. For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysisGROUND FLOOR ---- etc., complete with all lead Sqm747.47747.47214.8FalseNoneNoneFalseNoneFalse160556.5560
3622740131621NoneV-2,9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm thick- ness to be specified by the manufacturer, of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 1 Cement : 4 Coarse sand, jointing with grey cement slurry at 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.GROUND FLOOR ---- etc., complete with all lead Sqm1080.491080.49132.6FalseNoneNoneFalseNoneFalse143272.9740
3622741131621NoneV-2,9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOOR ---- etc., complete with all lead Sqm1761.111761.11540.8FalseNoneNoneFalseNoneFalse952408.2880
3622742131621NoneV-2,11.28Providing and fixing stainless steel Grade 304 railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature wherever required and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.GROUND FLOOR ---- etc., complete with all lead Kg686.7686.7677.3FalseNoneNoneFalseNoneFalse465101.910
3622743131621NoneV-2,8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc., complete with all lead Sqm154.36154.3612832.2FalseNoneNoneFalseNoneFalse1980778.3920
3622744131621NoneV-2,8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted with silicon additives, New work Two coats applied at 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied at 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc., complete with all lead Sqm189.6189.61799.9FalseNoneNoneFalseNoneFalse341261.040
3622745131621NoneV-2,8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc., complete with all lead Sqm60.7760.77250.1FalseNoneNoneFalseNoneFalse15198.5770
3622746131621NoneV-2,8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc., complete with all lead Sqm139.77139.77262.8FalseNoneNoneFalseNoneFalse36731.5560
3622747131621NoneV-2,8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work hard and soft wood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc., complete with all lead Sqm64.4264.42581.8FalseNoneNoneFalseNoneFalse37479.5560
3622748131621NoneV-2,8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. Final coat to be done in 1 or 2 layers without gap of time.GROUND FLOOR ---- etc., complete with all lead Sqm822.83822.83581.8FalseNoneNoneFalseNoneFalse478722.4940
3622749131621NoneV-1 (CPWD),5.44.1Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universalaluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -inCharge. Material shall confirm to ASTM 6063. Floor Joint of 100 mm gapGROUND FLOOR ---- etc., complete with all lead m5800.155800.15105.0FalseNoneNoneFalseNoneFalse609015.750
3622750131621NoneV-1 (CPWD),5.45.1Providing and fixing of expansion joint system related with wall joint internal/external location as per drawings and direction of Engineer-InCharge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. Material shall confirm to ASTM 6063 Wall Joint of 100 mm gapGROUND FLOOR ---- etc., complete with all lead m4835.54835.5105.0FalseNoneNoneFalseNoneFalse507727.50
3622751131621NoneV-1 (CPWD),5.46.1Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed toaccommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. Material shall confirm to ASTM 6063. Roof Joint of 100 mm gapGROUND FLOOR ---- etc., complete with all lead m5424.25424.2231.0FalseNoneNoneFalseNoneFalse1252990.20
3622752131621NoneV-2,11.16.2Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc. trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.GROUND FLOOR ---- etc., complete with all lead Kg178.66178.661260.0FalseNoneNoneFalseNoneFalse225111.60
3622753131621NoneV-2,18.1Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account.The weight of aluminium extruded section shall be taken for purpose of payment.GROUND FLOOR ---- etc., complete with all lead Kg494.67494.67546.0FalseNoneNoneFalseNoneFalse270089.820
3622754131621NoneV-2,18.2Designing, fabricating, testing, protection, installing and fixing in position semi grid unitized system of structural glazing with open joints for linear as well as curvilinear portions of the building for all heights and all levels, including:a Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III the system must passed the proof test at 1.5 times design wind pressure without any failure, including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop barrier-cum- smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:b Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/ structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.cProviding and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.dProviding and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.e Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom if required, making necessary holes of required sizes and of required numbers etc. complete.This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required :(Item full specification refer document-1 item no-v-2, 18.2 Sl No-1) ---- etc., complete with all lead Sqm3263.353263.3584.0FalseNoneNoneFalseNoneFalse274121.40
3622755131621NoneV-1 (CPWD),9.137Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 Part-II, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet zinc coating not less than 120 gm/m2 duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge panneling to be paid for separately.GROUND FLOOR ---- etc., complete with all lead Sqm6444.956444.957.2FalseNoneNoneFalseNoneFalse46403.640
3622756131621NoneV-1 (CPWD),9.136Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet zinc coating not less than 120 gm/sqm duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm minimum alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge Dash fastener to bepaid for separately.GROUND FLOOR ---- etc., complete with all lead m1462.751462.7515.6FalseNoneNoneFalseNoneFalse22818.90
3622757131621NoneV-2,7.41Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections galvanising at 120 grams per m2 including both side consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick minimum sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm Minimum sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick Minimum sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size24x24X3000 mm made of 0.40 mm thick minimum sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws at 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.GROUND FLOOR ---- etc., complete with all lead Sqm2057.672057.67907.23FalseNoneNoneFalseNoneFalse1866779.95410
3622758131621NoneV-2,7.31Providing and fixing in position 12mm thick plaster of paris Gypsum anhydrous for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications.GROUND FLOOR ---- etc., complete with all lead Sqm1548.421548.42388.81FalseNoneNoneFalseNoneFalse602041.18020
3622759131621NoneV-2,10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 1 cement : 4 coarse sand, joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2GROUND FLOOR ---- etc., complete with all lead Sqm4868.894868.8927.42FalseNoneNoneFalseNoneFalse133504.96380
3622760131621NoneV-3,15.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/EpoxyGROUND FLOOR ---- etc., complete with all lead No247.94247.9410.0FalseNoneNoneFalseNoneFalse2479.40
3622761131621NoneV-2,11.36.1Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge: Pre- laminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications.GROUND FLOOR ---- etc., complete with all lead Sqm1090.211090.214.72FalseNoneNoneFalseNoneFalse5145.79120
3622762131621None18-19 SR,10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.GROUND FLOOR ---- etc., complete with all lead Sqm291.7291.710.0FalseNoneNoneFalseNoneFalse2917.00
3622763131621NoneV-2,15.12Newly Constructed Roof/Podium with PU Waterproof coating - Above 500 m2--Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied at 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer at0.2L/m2 and protection with 120gsm Geo-textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability no cracks up to 3.2mm Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo-textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification.GROUND FLOOR ---- etc., complete with all lead Sqm1415.941415.9490.11FalseNoneNoneFalseNoneFalse127590.35340
3622764131621NoneV-5,10.1.7Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3GROUND FLOOR ---- etc., complete with all lead Rmtr499.53499.5324.0FalseNoneNoneFalseNoneFalse11988.720
3622765131621NoneV-1,1.4.1Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mGROUND FLOOR ---- etc., complete with all lead Cum294.13294.131007.28FalseNoneNoneFalseNoneFalse296271.26640
3622766131621NoneV-3,3.1Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of workGROUND FLOOR ---- etc., complete with all lead Cum103.31103.31315.9FalseNoneNoneFalseNoneFalse32635.6290
3622767131621NoneV-3,4.11 AMaking 50 mm x 50 mm furrows, 25mm/ 50mm deep, 45 degrees to the center line of the road and at one metre interval in the existing thin bituminous wearing coarse including sweeping and disposal of excavated material.25 mm deep furrow cuttingGROUND FLOOR ---- etc., complete with all lead Sqm9.729.723159.0FalseNoneNoneFalseNoneFalse30705.480
3622768131621NoneV-3,3.7Compacting original ground supporting embankment-Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.GROUND FLOOR ---- etc., complete with all lead Cum127.62127.62473.85FalseNoneNoneFalseNoneFalse60472.7370
3622769131621NoneV-3,4.2 VConstruction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 .For Grading -V MaterialGROUND FLOOR ---- etc., complete with all lead Cum3022.73022.7315.9FalseNoneNoneFalseNoneFalse954870.930
3622770131621NoneV-3,4.17Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface andcompactingwithvibratoryrollertoachievethedesireddensity. GROUND FLOOR ---- etc., complete with all lead Cum3110.213110.21315.9FalseNoneNoneFalseNoneFalse982515.3390
3622771131621NoneV-3,5.1Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/m2 using mechanical means.GROUND FLOOR ---- etc., complete with all lead Sqm49.8349.833159.0FalseNoneNoneFalseNoneFalse157412.970
3622772131621NoneV-3,5.3Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broomGROUND FLOOR ---- etc., complete with all lead Sqm14.5814.583159.0FalseNoneNoneFalseNoneFalse46058.220
3622773131621NoneV-3,5.6 AProviding and laying Bituminous Macadam with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG- 40 at 3.3% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compactionGROUND FLOOR ---- etc., complete with all lead Cum9429.079429.07236.93FalseNoneNoneFalseNoneFalse2234029.55510
3622774131621NoneV-3,5.31Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 at 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision.GROUND FLOOR ---- etc., complete with all lead Cum12338.7412338.7472.15FalseNoneNoneFalseNoneFalse890240.0910
3622775131621NoneV-3,8.42.2Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. The cost of PCC shall be paid extra600 x 200 x 100 mm Kerb StoneGROUND FLOOR ---- etc., complete with all lead m303.85303.85962.0FalseNoneNoneFalseNoneFalse292303.70
3622776131621NoneV-3,4.19Construction of Median and Island above road level with approved material deposited at site from roadway cutting and excavation for drain and foundation of other structures, spread, graded and compacted as per clause 408GROUND FLOOR ---- etc., complete with all lead Cum446.05446.05129.87FalseNoneNoneFalseNoneFalse57928.51350
3622777131621NoneV-3,8.1Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces.GROUND FLOOR ---- etc., complete with all lead Sqm132.48132.48673.4FalseNoneNoneFalseNoneFalse89212.0320
3622778131621NoneV-1,1.14.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 to 6 m.GROUND FLOOR ---- etc., complete with all lead Cum142.2142.2221.14FalseNoneNoneFalseNoneFalse31446.1080
3622779131621NoneV-1,1.15.3Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 3m, but not exceeding 4.5mGROUND FLOOR ---- etc., complete with all lead Cum562.73562.7362.01FalseNoneNoneFalseNoneFalse34894.88730
3622780131621NoneV-1,2.5.2BOTTOM SLAB-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.GROUND FLOOR ---- etc., complete with all lead Cum8566.498566.4945.65FalseNoneNoneFalseNoneFalse391060.26850
3622781131621NoneV-1,2.5.2RC WALL-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.GROUND FLOOR ---- etc., complete with all lead Cum9148.689148.6899.82FalseNoneNoneFalseNoneFalse913221.23760
3622782131621NoneV-1,2.11 hSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structuresGROUND FLOOR ---- etc., complete with all lead Tonne96029.9796029.9726.9FalseNoneNoneFalseNoneFalse2583206.1930
3622783131621NoneV-2,11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.GROUND FLOOR ---- etc., complete with all lead Sqm5442.565442.568.4FalseNoneNoneFalseNoneFalse45717.5040
3622784131621NoneV-2,15.13STP inside waterproofing with Anticorrosive & Protective Coating--Providing and Applying two component coal tar epoxy-based coating on inside surface of Sewage & Effluent treatment tank at 0.30 kg/m2 in 2 coats to achieve a DFT of 200 microns when fully cured. Ensure that this coating is applied over the protective plaster and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Scratch resistance, for 7kg load as per ASTM : D 7027 - 05, Chemical resistance, immersion in dilute acid alkali & salt solutions 7 days confirms to ASTM : C 868, Salt Spray resistance confirms to ASTM : B 117. The finished cost to include surface preparation completely as per specification.GROUND FLOOR ---- etc., complete with all lead Sqm2023.642023.64497.39FalseNoneNoneFalseNoneFalse1006538.29960
3622785131621NoneV-2,8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 1 cement : 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 1 cement : 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc., complete with all lead Sqm450.91450.91591.0FalseNoneNoneFalseNoneFalse266487.810
3622786131621NoneV-2,8.21Providing White washing with lime to give an even shade :New work three coats with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc., complete with all lead Sqm31.631.61050.81FalseNoneNoneFalseNoneFalse33205.5960
3622787131621NoneV-2,8.28Finishing walls with water proofing cement paint of required shade :New work Two coats applied at 4.84 kg/10 Sqm to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc., complete with all lead Sqm108.17108.17454.61FalseNoneNoneFalseNoneFalse49175.16370
3622788131621NoneV-5,18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs weight of cover 23 kgs and weight of frame 15 kgsand necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.GROUND FLOOR ---- etc., complete with all lead No2384.612384.6122.0FalseNoneNoneFalseNoneFalse52461.420
3622789131621NoneV-2,15.14UGT/OHT inside waterproofing with Anti-microbial Coating---Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio Base: Hardener: Water 1:1:1 to be applied at 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification.GROUND FLOOR ---- etc., complete with all lead Sqm2033.362033.36252.83FalseNoneNoneFalseNoneFalse514094.40880
3622790131621NoneV-1,2.5.2Base slab -Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.GROUND FLOOR ---- etc., complete with all lead Cum8732.838732.8347.34FalseNoneNoneFalseNoneFalse413412.17220
3622791131621NoneV-1,2.5.2Side wall-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.GROUND FLOOR ---- etc., complete with all lead Cum11227.9311227.9369.42FalseNoneNoneFalseNoneFalse779442.90060
3622792131621NoneV-2,17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel at 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.GROUND FLOOR ---- etc., complete with all lead Sqm1127.891127.89432.9FalseNoneNoneFalseNoneFalse488263.5810
3622793131621NoneV-3,16.15cProviding and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row. Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1101.6.GROUND FLOOR ---- etc., complete with all lead m4053.364053.3612.0FalseNoneNoneFalseNoneFalse48640.320
3622794131621NoneV-3,6.8.1Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in- charge. WMM/WBM Base to be paid separately if necessary as per relevant technical specificationGROUND FLOOR ---- etc., complete with all lead Sqm1298.051298.0575.0FalseNoneNoneFalseNoneFalse97353.750
3622795131621NoneV-1,1.4.2Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mGROUND FLOOR ---- etc., complete with all lead Cum314.79314.7916.97FalseNoneNoneFalseNoneFalse5341.98630
3622796131621NoneV-2,17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations at 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.GROUND FLOOR ---- etc., complete with all lead Each1364.891364.8970.0FalseNoneNoneFalseNoneFalse95542.30
3622797131621NoneV-2,17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-chargeGROUND FLOOR ---- etc., complete with all lead Cum1217.831217.832.83FalseNoneNoneFalseNoneFalse3446.45890
3622798131621NoneV-2,17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineerin-charge.GROUND FLOOR ---- etc., complete with all lead Cum1441.461441.461.41FalseNoneNoneFalseNoneFalse2032.45860
3622799131621NoneV-2,17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.GROUND FLOOR ---- etc., complete with all lead Cum1448.761448.761.41FalseNoneNoneFalseNoneFalse2042.75160
3622800131621NoneV-2,17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin-charge.GROUND FLOOR ---- etc., complete with all lead Cum1627.421627.421.41FalseNoneNoneFalseNoneFalse2294.66220
3622801131621NoneV-2,17.14Providing and laying 100mm thick pre-cast cover slabs over Road side drains / utility ducts / Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 550 at 6kg/ m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. GROUND FLOOR ---- etc., complete with all lead Sqm1422.021422.0210.0FalseNoneNoneFalseNoneFalse14220.20
3622802131621NoneV-3,8.18Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25, fixed in position including finishing and lettering but excluding paintingGROUND FLOOR ---- etc., complete with all lead Nos909.12909.12287.67FalseNoneNoneFalseNoneFalse261526.55040
3622803131621NoneV-2,11.56Fencing with G.I. barbed wire R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 m minimum, between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post cost of R.C.C. posts, struts, earth work and concrete to be paid for separately :- Payment to be made per metre cost of total length of barbed wire used.GROUND FLOOR ---- etc., complete with all lead m14.5814.584300.0FalseNoneNoneFalseNoneFalse62694.00
3622804131621NoneV-1,2.5.2COLUMNS-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.FIRST & TERRACE FLOOR ---- etc., complete with all lead Cum14280.2614280.26187.3FalseNoneNoneFalseNoneFalse2674692.6980
3622805131621NoneV-1,2.5.2RCC BEAMS & LINTEL-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.FIRST & TERRACE FLOOR ---- etc., complete with all lead Cum13440.2413440.24305.1FalseNoneNoneFalseNoneFalse4100617.2240
3622806131621NoneV-1,2.5.2RCC SLAB & STAIRCASE--Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.FIRST & TERRACE FLOOR ---- etc., complete with all lead Cum12600.2312600.23424.5FalseNoneNoneFalseNoneFalse5348797.6350
3622807131621NoneV-1,2.5.1CILL-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWorkFIRST & TERRACE FLOOR ---- etc., complete with all lead Cum11801.0911801.0927.5FalseNoneNoneFalseNoneFalse324529.9750
3622808131621NoneV-1,2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.FIRST & TERRACE FLOOR ---- etc., complete with all lead Tonne109813.3109813.3143.14FalseNoneNoneFalseNoneFalse15718675.7620
3622809131621NoneV-2,6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 Part - I - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.FIRST & TERRACE FLOOR ---- etc., complete with all lead Cum1608.11608.13623.7FalseNoneNoneFalseNoneFalse5827271.970
3622810131621NoneV-2,6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 Part - I - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm1355.221355.22445.63FalseNoneNoneFalseNoneFalse603926.68860
3622811131621NoneV-2,12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications.FIRST & TERRACE FLOOR ---- etc., complete with all lead Cum121300.75121300.753.04FalseNoneNoneFalseNoneFalse368754.280
3622812131621NoneV-2,12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.FIRST & TERRACE FLOOR ---- etc., complete with all lead Nos1247.191247.1939.0FalseNoneNoneFalseNoneFalse48640.410
3622813131621NoneV-2,22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mmFIRST & TERRACE FLOOR ---- etc., complete with all lead No675.15675.1578.0FalseNoneNoneFalseNoneFalse52661.70
3622814131621NoneV-2,22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mmFIRST & TERRACE FLOOR ---- etc., complete with all lead No460.33460.3339.0FalseNoneNoneFalseNoneFalse17952.870
3622815131621NoneV-2,22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mmFIRST & TERRACE FLOOR ---- etc., complete with all lead No184.13184.1352.0FalseNoneNoneFalseNoneFalse9574.760
3622816131621NoneV-2,22.15.9Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mmFIRST & TERRACE FLOOR ---- etc., complete with all lead No85.9385.93117.0FalseNoneNoneFalseNoneFalse10053.810
3622817131621NoneV-2,22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mmFIRST & TERRACE FLOOR ---- etc., complete with all lead No122.76122.7613.0FalseNoneNoneFalseNoneFalse1595.880
3622818131621NoneV-2,12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.FIRST & TERRACE FLOOR ---- etc., complete with all lead No1291.391291.3939.0FalseNoneNoneFalseNoneFalse50364.210
3622819131621NoneV-2,10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmFIRST & TERRACE FLOOR ---- etc., complete with all lead Nos71.5171.51234.0FalseNoneNoneFalseNoneFalse16733.340
3622820131621NoneV-2,20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.FIRST & TERRACE FLOOR ---- etc., complete with all lead Rmtr63.8363.83234.0FalseNoneNoneFalseNoneFalse14936.220
3622821131621NoneV-2,12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 part-I 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side CommercialFIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm4077.934077.93112.32FalseNoneNoneFalseNoneFalse458033.09760
3622822131621NoneV-2,12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVCMatching to RAL-9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be madeFIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm8266.358266.35172.8FalseNoneNoneFalseNoneFalse1428425.280
3622823131621NoneV-2,12.85Providing & fixing of louvered ventilator made out of multi chambered UPVCMatching to RAL-9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm7020.387020.3823.76FalseNoneNoneFalseNoneFalse166804.22880
3622824131621NoneV-2,11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingFIRST & TERRACE FLOOR ---- etc., complete with all lead Kg206.23206.234127.8FalseNoneNoneFalseNoneFalse851276.1940
3622825131621NoneV-2,12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm, with necessary accessories and screws etc. complete.FIRST & TERRACE FLOOR ---- etc., complete with all lead Nos1367.51367.539.0FalseNoneNoneFalseNoneFalse53332.50
3622826131621NoneV-2,12.93.1Providing and fixing factory made single extruded WPC Wood Polymer Composite solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 Suspension Grade, calcium carbonate and natural fibres wood powder/rice husk/ wheat husk and non toxic additives maximum toxicity index of 12 for 100 g fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N Face & 1100 N Edge, minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. Fixtures shall be paid for separatelySize 62 x 100mmFIRST & TERRACE FLOOR ---- etc., complete with all lead m861.74861.74217.8FalseNoneNoneFalseNoneFalse187686.9720
3622827131621NoneV-2,12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC Wood PolymerComposite solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 Suspension Grade, calcium carbonate and natural fibers wood powder/rice husk/wheat husk and non toxic additives maximum toxicity index of 12 for 100 g having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N Face & 900 N Edge, minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.Cost of Fixtures to be paid separately30 mm thicknessFIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm4278.034278.0369.3FalseNoneNoneFalseNoneFalse296467.4790
3622828131621NoneV-2,11.35.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. Glazing, paneling and dash fasteners to be paid for separately :For Fixed Portion : Anodised aluminium anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15 including cost of materials, labour, usage charges of machinery complete as per specifications.FIRST & TERRACE FLOOR ---- etc., complete with all lead Kg554.85554.85129.6FalseNoneNoneFalseNoneFalse71908.560
3622829131621NoneV-2,11.37.1Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . Cost of aluminium snap beading shall be paid in basic item:With float glass panes of 4.0 mm thickness weight not less than 10kg/ Sqm including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm1212.821212.8212.96FalseNoneNoneFalseNoneFalse15718.14720
3622830131621NoneV-2,8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... InsideFIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm383.0383.04898.8FalseNoneNoneFalseNoneFalse1876240.40
3622831131621NoneV-2,8.1Providing 6 mm cement plaster with cement mortar 1:3 1 cement : 3 fine sand on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm259.01259.014831.3FalseNoneNoneFalseNoneFalse1251355.0130
3622832131621NoneV-2,8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. OutsideFIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm428.42428.421913.3FalseNoneNoneFalseNoneFalse819695.9860
3622833131621NoneV-2,8.3.1Providing 20 mm cement plaster of mix :1:4 1 cement: 4 fine sand to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm434.55434.5576.96FalseNoneNoneFalseNoneFalse33442.9680
3622834131621NoneV-2,8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment.Plaster mesh 150mm wideFIRST & TERRACE FLOOR ---- etc., complete with all lead Rmtr46.6546.657098.0FalseNoneNoneFalseNoneFalse331121.70
3622835131621NoneV-2,7.18Providing and laying cinder concrete in cement 1:15 1 cement : 15 cinder of 12.5mm nominal gauge on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.FIRST & TERRACE FLOOR ---- etc., complete with all lead Cum2475.982475.9899.65FalseNoneNoneFalseNoneFalse246731.4070
3622836131621NoneV-2,15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed at 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix at 0.5 kg/bag of cement. For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysisFIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm754.95754.95377.77FalseNoneNoneFalseNoneFalse285197.46150
3622837131621NoneV-2,8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.FIRST & TERRACE FLOOR ---- etc., complete with all lead Rmtr63.8363.831464.32FalseNoneNoneFalseNoneFalse93467.54560
3622838131621NoneV-2,9.17.2Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 1 cement: 3 coarse sand, jointing with grey cement slurry at 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mmFIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm1442.381442.381148.64FalseNoneNoneFalseNoneFalse1656775.36320
3622839131621NoneV-2,9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS : 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.Size of Tile 600x600 mmFIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm1627.741627.74661.38FalseNoneNoneFalseNoneFalse1076554.68120
3622840131621NoneV-2,9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 1:4 1 cement : 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm3500.983500.98526.12FalseNoneNoneFalseNoneFalse1841935.59760
3622841131621NoneV-2,10.18Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 1 cement : 3 coarse sand proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm4123.354123.35102.54FalseNoneNoneFalseNoneFalse422808.3090
3622842131621NoneV-2,9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm6540.416540.4189.92FalseNoneNoneFalseNoneFalse588113.66720
3622843131621NoneV-2,40180Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 1 cement : 4 coarse sand, joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm4832.884832.8814.26FalseNoneNoneFalseNoneFalse68916.86880
3622844131621NoneV-2,8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 1 cement: 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm362.13362.131682.16FalseNoneNoneFalseNoneFalse609160.60080
3622845131621NoneV-2,9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm thick- ness to be specified by the manufacturer, of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 1 Cement : 4 Coarse sand, jointing with grey cement slurry at 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm1091.31091.3221.43FalseNoneNoneFalseNoneFalse241646.5590
3622846131621NoneV-2,9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm1778.731778.73918.25FalseNoneNoneFalseNoneFalse1633318.82250
3622847131621NoneV-2,11.28Providing and fixing stainless steel Grade 304 railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature wherever required and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.FIRST & TERRACE FLOOR ---- etc., complete with all lead Kg693.57693.57264.89FalseNoneNoneFalseNoneFalse183719.75730
3622848131621NoneV-2,8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm155.9155.99698.6FalseNoneNoneFalseNoneFalse1512011.740
3622849131621NoneV-2,8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted with silicon additives, New work Two coats applied at 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied at 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm191.5191.51913.3FalseNoneNoneFalseNoneFalse366396.950
3622850131621NoneV-2,8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm61.3861.38202.9FalseNoneNoneFalseNoneFalse12454.0020
3622851131621NoneV-2,8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm141.17141.17202.9FalseNoneNoneFalseNoneFalse28643.3930
3622852131621NoneV-2,8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work hard and soft wood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm65.0665.06269.57FalseNoneNoneFalseNoneFalse17538.22420
3622853131621NoneV-2,8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. Final coat to be done in 1 or 2 layers without gap of time.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm831.05831.05269.57FalseNoneNoneFalseNoneFalse224026.14850
3622854131621NoneV-2,11.16.2Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc. trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.FIRST & TERRACE FLOOR ---- etc., complete with all lead Kg180.45180.451260.0FalseNoneNoneFalseNoneFalse227367.00
3622855131621NoneV-2,18.1Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account.The weight of aluminium extruded section shall be taken for purpose of payment.FIRST & TERRACE FLOOR ---- etc., complete with all lead Kg499.61499.61546.0FalseNoneNoneFalseNoneFalse272787.060
3622856131621NoneV-2,18.2Designing, fabricating, testing, protection, installing and fixing in position semi grid unitized system of structural glazing with open joints for linear as well as curvilinear portions of the building for all heights and all levels, including:a Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III the system must passed the proof test at 1.5 times design wind pressure without any failure, including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop barrier-cum- smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:b Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/ structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.cProviding and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.dProviding and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.e Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom if required, making necessary holes of required sizes and of required numbers etc. complete.This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the cur- tain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing including width (Item full specification refer document-1 item no-v-2, 18.2 Sl No-2) ---- etc., complete with all lead Sqm3295.983295.9884.0FalseNoneNoneFalseNoneFalse276862.320
3622857131621NoneV-1 (CPWD),9.137Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 Part-II, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet zinc coating not less than 120 gm/m2 duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge panneling to be paid for separately.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm6444.956444.957.2FalseNoneNoneFalseNoneFalse46403.640
3622858131621NoneV-1 (CPWD),9.136Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet zinc coating not less than 120 gm/sqm duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm minimum alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge Dash fastener to bepaid for separately.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm1462.751462.7515.6FalseNoneNoneFalseNoneFalse22818.90
3622859131621NoneV-2,7.41Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections galvanising at 120 grams per m2 including both side consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick minimum sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm Minimum sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick Minimum sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size24x24X3000 mm made of 0.40 mm thick minimum sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws at 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm2078.252078.25512.54FalseNoneNoneFalseNoneFalse1065186.2550
3622860131621NoneV-2,7.31Providing and fixing in position 12mm thick plaster of paris Gypsum anhydrous for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm1563.91563.9219.66FalseNoneNoneFalseNoneFalse343526.2740
3622861131621NoneV-1 (CPWD),5.44.1Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universalaluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -inCharge. Material shall confirm to ASTM 6063. Floor Joint of 100 mm gapFIRST & TERRACE FLOOR ---- etc., complete with all lead m5800.155800.15105.0FalseNoneNoneFalseNoneFalse609015.750
3622862131621NoneV-1 (CPWD),5.45.1Providing and fixing of expansion joint system related with wall joint internal/external location as per drawings and direction of Engineer-InCharge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. Material shall confirm to ASTM 6063 Wall Joint of 100 mm gapFIRST & TERRACE FLOOR ---- etc., complete with all lead m4835.54835.5105.0FalseNoneNoneFalseNoneFalse507727.50
3622863131621NoneV-1 (CPWD),5.46.1Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed toaccommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. Material shall confirm to ASTM 6063. Roof Joint of 100 mm gapFIRST & TERRACE FLOOR ---- etc., complete with all lead m5424.25424.2231.0FalseNoneNoneFalseNoneFalse1252990.20
3622864131621NoneV-1,2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.DUMMY COLUMNFIRST & TERRACE FLOOR ---- etc., complete with all lead Cum13835.7613835.768.38FalseNoneNoneFalseNoneFalse115943.66880
3622865131621NoneV-2,11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm5496.995496.996.72FalseNoneNoneFalseNoneFalse36939.77280
3622866131621NoneV-2,8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm122.76122.769730.07FalseNoneNoneFalseNoneFalse1194463.39320
3622867131621NoneV-2,15.12Newly Constructed Roof/Podium with PU Waterproof coating - Above 500 m2--Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied at 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer at0.2L/m2 and protection with 120gsm Geo-textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability no cracks up to 3.2mm Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo-textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification.FIRST & TERRACE FLOOR ---- etc., complete with all lead Sqm1430.11430.1525.37FalseNoneNoneFalseNoneFalse751331.6370
3622868131621NoneV-5,10.1.7Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3FIRST & TERRACE FLOOR ---- etc., complete with all lead Rmtr504.52504.5263.0FalseNoneNoneFalseNoneFalse31784.760
3622869131621NoneV-2,11.32Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. The laps and wastages shall not be measured separatelyFIRST & TERRACE FLOOR ---- etc., complete with all lead Tonne109813.3109813.31.24FalseNoneNoneFalseNoneFalse136168.4920
3622870131621NoneV-1,2.5.2COLUMNS-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.TERRACE FLOOR ---- etc., complete with all lead Cum14421.6514421.6539.07FalseNoneNoneFalseNoneFalse563453.86550
3622871131621NoneV-1,2.5.2RCC BEAMS & LINTEL-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.TERRACE FLOOR ---- etc., complete with all lead Cum13573.3113573.3123.28FalseNoneNoneFalseNoneFalse315986.65680
3622872131621NoneV-1,2.5.2RCC SLAB-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork.TERRACE FLOOR ---- etc., complete with all lead Cum12724.9812724.9825.35FalseNoneNoneFalseNoneFalse322578.2430
3622873131621NoneV-1,2.5.1CILL-Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWorkTERRACE FLOOR ---- etc., complete with all lead Cum11917.9311917.932.05FalseNoneNoneFalseNoneFalse24431.75650
3622874131621NoneV-1,2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.TERRACE FLOOR ---- etc., complete with all lead Tonne110900.56110900.5611.77FalseNoneNoneFalseNoneFalse1305299.59120
3622875131621NoneV-2,6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 Part - I - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.TERRACE FLOOR ---- etc., complete with all lead Sqm1624.021624.02421.66FalseNoneNoneFalseNoneFalse684784.27320
3622876131621NoneV-2,12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVCMatching to RAL-9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be madeTERRACE FLOOR ---- etc., complete with all lead Sqm8348.198348.196.75FalseNoneNoneFalseNoneFalse56350.28250
3622877131621NoneV-2,11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingTERRACE FLOOR ---- etc., complete with all lead Kg208.27208.27141.75FalseNoneNoneFalseNoneFalse29522.27250
3622878131621NoneV-2,40664Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.TERRACE FLOOR ---- etc., complete with all lead Sqm5551.415551.4112.6FalseNoneNoneFalseNoneFalse69947.7660
3622879131621NoneV-2,8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... InsideTERRACE FLOOR ---- etc., complete with all lead Sqm386.79386.79314.0FalseNoneNoneFalseNoneFalse121452.060
3622880131621NoneV-2,8.1Providing 6 mm cement plaster with cement mortar 1:3 1 cement : 3 fine sand on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR ---- etc., complete with all lead Sqm261.58261.58209.0FalseNoneNoneFalseNoneFalse54670.220
3622881131621NoneV-2,8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.TERRACE FLOOR ---- etc., complete with all lead Sqm123.97123.97523.0FalseNoneNoneFalseNoneFalse64836.310
3622882131621NoneV-2,8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. OutsideTERRACE FLOOR ---- etc., complete with all lead Sqm432.66432.66698.66FalseNoneNoneFalseNoneFalse302282.23560
3622883131621NoneV-2,15.12Newly Constructed Roof/Podium with PU Waterproof coating - Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied at 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer at0.2L/m2 and protection with 120gsm Geo-textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability no cracks up to 3.2mm Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo-textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification.TERRACE FLOOR ---- etc., complete with all lead Sqm1444.261444.262693.0FalseNoneNoneFalseNoneFalse3889392.180
3622884131621NoneV-1,2.1.6Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates.Including FormWorkTERRACE FLOOR ---- etc., complete with all lead Cum7739.57739.5134.65FalseNoneNoneFalseNoneFalse1042123.6750
3622885131621NoneV-2,8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR ---- etc., complete with all lead Sqm157.44157.44523.0FalseNoneNoneFalseNoneFalse82341.120
3622886131621NoneV-2,8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted with silicon additives, New work Two coats applied at 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied at 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR ---- etc., complete with all lead Sqm193.39193.39698.66FalseNoneNoneFalseNoneFalse135113.85740
3622887131621NoneV-2,8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR ---- etc., complete with all lead Sqm61.9961.9919.35FalseNoneNoneFalseNoneFalse1199.50650
3622888131621NoneV-2,8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR ---- etc., complete with all lead Sqm142.57142.5719.35FalseNoneNoneFalseNoneFalse2758.72950
3622889131621NoneV-5,10.1.7Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3TERRACE FLOOR ---- etc., complete with all lead Rmtr509.52509.52120.0FalseNoneNoneFalseNoneFalse61142.40
3622890131621NoneV-2,11.16.2Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc. trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.TERRACE FLOOR ---- etc., complete with all lead Kg182.24182.248220.0FalseNoneNoneFalseNoneFalse1498012.80
3622891131621NoneV-2,7.34Providing and fixing 6mm Clear/opal white/solar bronze /blue/green tinted Multi wall poly carbonate sheet for Tubular structure. The work including cost of all materials, labour charges and usage charges of machinery for cutting, welding, grinding and erection equipments, with all lead, transportation, loading and unloading and all other incidental charges etc. complete as per specification and directions of the Engineer in charge of the work.TERRACE FLOOR ---- etc., complete with all lead Sqm3874.093874.09328.8FalseNoneNoneFalseNoneFalse1273800.7920
3622892131621NoneV-6,2.2.1ELECTRICAL--Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead Point326.94326.94245.0FalseNoneNoneFalseNoneFalse80100.30
3622893131621NoneV-6,2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead Point460.64460.64379.0FalseNoneNoneFalseNoneFalse174582.560
3622894131621NoneV-6,2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead Point674.55674.55575.0FalseNoneNoneFalseNoneFalse387866.250
3622895131621NoneV-6,2.2.4Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete with all lead Point822.83822.8353.0FalseNoneNoneFalseNoneFalse43609.990
3622896131621NoneV-6,2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches ---- etc., complete with all lead Point1202.031202.0330.0FalseNoneNoneFalseNoneFalse36060.90
3622897131621NoneV-6,3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- etc., complete with all lead Each167.73167.73195.0FalseNoneNoneFalseNoneFalse32707.350
3622898131621NoneV-6,3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way ---- etc., complete with all lead Each193.25193.25245.0FalseNoneNoneFalseNoneFalse47346.250
3622899131621NoneV-6,3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete with all lead Each215.13215.1386.0FalseNoneNoneFalseNoneFalse18501.180
3622900131621NoneV-6,3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete with all lead Each267.39267.3994.0FalseNoneNoneFalseNoneFalse25134.660
3622901131621NoneV-6,3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete with all lead Each317.22317.22185.0FalseNoneNoneFalseNoneFalse58685.70
3622902131621NoneV-6,3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete with all lead Each387.71387.71282.0FalseNoneNoneFalseNoneFalse109334.220
3622903131621NoneV-6,3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete with all lead Each166.51166.51195.0FalseNoneNoneFalseNoneFalse32469.450
3622904131621NoneV-6,3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- etc., complete with all lead Each195.68195.68245.0FalseNoneNoneFalseNoneFalse47941.60
3622905131621NoneV-6,3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete with all lead Each212.7212.786.0FalseNoneNoneFalseNoneFalse18292.20
3622906131621NoneV-6,3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete with all lead Each284.4284.494.0FalseNoneNoneFalseNoneFalse26733.60
3622907131621NoneV-6,3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all lead Each345.17345.17185.0FalseNoneNoneFalseNoneFalse63856.450
3622908131621NoneV-6,3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete with all lead Each418.1418.1282.0FalseNoneNoneFalseNoneFalse117904.20
3622909131621NoneV-6,3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead Each123.97123.972059.0FalseNoneNoneFalseNoneFalse255254.230
3622910131621NoneV-6,3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete with all lead Each201.76201.7638.0FalseNoneNoneFalseNoneFalse7666.880
3622911131621NoneV-6,3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all lead Each207.83207.83760.0FalseNoneNoneFalseNoneFalse157950.80
3622912131621NoneV-6,3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead Each433.9433.9272.0FalseNoneNoneFalseNoneFalse118020.80
3622913131621NoneV-6,3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead Each396.22396.22172.0FalseNoneNoneFalseNoneFalse68149.840
3622914131621NoneV-6,3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all lead Each286.83286.83252.0FalseNoneNoneFalseNoneFalse72281.160
3622915131621NoneV-6,3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete with all lead Each218.77218.7780.0FalseNoneNoneFalseNoneFalse17501.60
3622916131621NoneV-6,1.13Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead No142.2142.2268.0FalseNoneNoneFalseNoneFalse38109.60
3622917131621NoneV-6,5.45.2Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB Without MCB.The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. SP & N 20Amps ---- etc., complete with all lead Each1180.151180.157.0FalseNoneNoneFalseNoneFalse8261.050
3622918131621NoneV-6,5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all lead Each504.39504.39609.0FalseNoneNoneFalseNoneFalse307173.510
3622919131621NoneV-6,5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all lead Sq CM0.520.521894000.0FalseNoneNoneFalseNoneFalse984880.00
3622920131621NoneV-6,5.15.9Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., complete with all lead Each10315.110315.115.0FalseNoneNoneFalseNoneFalse154726.50
3622921131621NoneV-6,5.15.13Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE250Amps 25kA ---- etc., complete with all lead Each25998.6225998.622.0FalseNoneNoneFalseNoneFalse51997.240
3622922131621NoneV-6,5.18.7Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps TPN ---- etc., complete with all lead Each2086.842086.8424.0FalseNoneNoneFalseNoneFalse50084.160
3622923131621NoneV-6,5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 63Amps TPN ---- etc., complete with all lead Each3753.163753.1627.0FalseNoneNoneFalseNoneFalse101335.320
3622924131621NoneV-6,1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all lead Mtr80.2280.228050.0FalseNoneNoneFalseNoneFalse645771.00
3622925131621NoneV-6,1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead Mtr94.894.820900.0FalseNoneNoneFalseNoneFalse1981320.00
3622926131621NoneV-6,1.2.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all lead Mtr125.19125.192195.0FalseNoneNoneFalseNoneFalse274792.050
3622927131621NoneV-6,1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all lead Mtr82.6582.653570.0FalseNoneNoneFalseNoneFalse295060.50
3622928131621NoneV-6,1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead Mtr96.0296.025405.0FalseNoneNoneFalseNoneFalse518988.10
3622929131621NoneV-6,1.3.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all lead Mtr120.32120.321090.0FalseNoneNoneFalseNoneFalse131148.80
3622930131621NoneV-6,2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete with all lead Mtr31.631.68280.0FalseNoneNoneFalseNoneFalse261648.00
3622931131621NoneV-6,2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete with all lead Mtr51.0551.0523465.0FalseNoneNoneFalseNoneFalse1197888.250
3622932131621NoneV-6,2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete with all lead Mtr76.5776.5711250.0FalseNoneNoneFalseNoneFalse861412.50
3622933131621NoneV-6,2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete with all lead Mtr111.82111.827135.0FalseNoneNoneFalseNoneFalse797835.70
3622934131621NoneV-6,2.3.6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 10 sqmm ---- etc., complete with all lead Mtr202.97202.97300.0FalseNoneNoneFalseNoneFalse60891.00
3622935131621NoneV-6,5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete with all lead Each4907.794907.7915.0FalseNoneNoneFalseNoneFalse73616.850
3622936131621NoneV-6,5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete with all lead Each6004.086004.0813.0FalseNoneNoneFalseNoneFalse78053.040
3622937131621NoneV-6,5.19.13Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 8 Way TP & N ---- etc., complete with all lead Each7403.07403.02.0FalseNoneNoneFalseNoneFalse14806.00
3622938131621NoneV-6,5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete with all lead Each2830.672830.6710.0FalseNoneNoneFalseNoneFalse28306.70
3622939131621NoneV-6,5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all lead Each898.18898.1820.0FalseNoneNoneFalseNoneFalse17963.60
3622940131621NoneV-6,5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN ---- etc., complete with all lead Each3699.683699.6849.0FalseNoneNoneFalseNoneFalse181284.320
3622941131621NoneV-6,5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete with all lead Each6255.666255.6622.0FalseNoneNoneFalseNoneFalse137624.520
3622942131621NoneV-6,5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete with all lead Each5198.275198.2719.0FalseNoneNoneFalseNoneFalse98767.130
3622943131621NoneV-6,32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 10 sqmm ---- etc., complete with all lead Km143422.06143422.060.65FalseNoneNoneFalseNoneFalse93224.3390
3622944131621NoneV-6,32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete with all lead Km107463.24107463.240.7FalseNoneNoneFalseNoneFalse75224.2680
3622945131621NoneV-6,32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25 sqmm ---- etc., complete with all lead Km169607.85169607.850.15FalseNoneNoneFalseNoneFalse25441.17750
3622946131621NoneV-6,32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete with all lead Km187246.95187246.950.2FalseNoneNoneFalseNoneFalse37449.390
3622947131621NoneV-6,32.111.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 50 sqmm ---- etc., complete with all lead Km217523.78217523.780.2FalseNoneNoneFalseNoneFalse43504.7560
3622948131621NoneV-6,32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete with all lead Km386390.24386390.240.1FalseNoneNoneFalseNoneFalse38639.0240
3622949131621NoneV-6,32.141.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 95 sqmm ---- etc., complete with all lead Km453605.51453605.510.05FalseNoneNoneFalseNoneFalse22680.27550
3622950131621NoneV-6,32.171.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 185 sqmm ---- etc., complete with all lead Km840106.36840106.360.06FalseNoneNoneFalseNoneFalse50406.38160
3622951131621NoneV-6,32.181.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 240 sqmm ---- etc., complete with all lead Km1048484.261048484.260.1FalseNoneNoneFalseNoneFalse104848.4260
3622952131621NoneV-6,32.191.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 300 sqmm ---- etc., complete with all lead Km1295633.421295633.420.2FalseNoneNoneFalseNoneFalse259126.6840
3622953131621NoneV-6,21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete with all lead Km25384.8425384.840.5FalseNoneNoneFalseNoneFalse12692.420
3622954131621NoneV-6,21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete with all lead Km37846.3437846.340.45FalseNoneNoneFalseNoneFalse17030.8530
3622955131621NoneV-6,21.07Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 120 sqmm to 300 sqmm ---- etc., complete with all lead Km39230.6839230.680.85FalseNoneNoneFalseNoneFalse33346.0780
3622956131621NonePWD SR 19-20,6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class metal only 32mm dia ---- etc., complete with all lead Each138.06138.0614.0FalseNoneNoneFalseNoneFalse1932.840
3622957131621NonePWD SR 19-20,6.11.4Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class metal only 50mm dia ---- etc., complete with all lead Each311.52311.5210.0FalseNoneNoneFalseNoneFalse3115.20
3622958131621NonePWD SR 19-20,6.11.5Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class metal only 75mm dia ---- etc., complete with all lead Each605.34605.3410.0FalseNoneNoneFalseNoneFalse6053.40
3622959131621NonePWD SR 19-20,6.11.6Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class metal only 63mm dia ---- etc., complete with all lead Each457.84457.845.0FalseNoneNoneFalseNoneFalse2289.20
3622960131621NonePWD SR 19-20,6.17.5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmm ---- etc., complete with all lead Each9.449.4416.0FalseNoneNoneFalseNoneFalse151.040
3622961131621NonePWD SR 19-20,6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete with all lead Each14.6814.6864.0FalseNoneNoneFalseNoneFalse939.520
3622962131621NonePWD SR 19-20,6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete with all lead Each37.7637.7632.0FalseNoneNoneFalseNoneFalse1208.320
3622963131621NonePWD SR 19-20,6.17.9Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 50 sqmm Long Barrel ---- etc., complete with all lead Each70.870.832.0FalseNoneNoneFalseNoneFalse2265.60
3622964131621NonePWD SR 19-20,6.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete with all lead Each141.59141.5932.0FalseNoneNoneFalseNoneFalse4530.880
3622965131621NonePWD SR 19-20,6.17.11Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 95 sqmm Long Barrel ---- etc., complete with all lead Each177.0177.08.0FalseNoneNoneFalseNoneFalse1416.00
3622966131621NonePWD SR 19-20,6.17.14Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 185 sqmm Long Barrel ---- etc., complete with all lead Each385.85385.858.0FalseNoneNoneFalseNoneFalse3086.80
3622967131621NonePWD SR 19-20,6.17.15Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 240 sqmm Long Barrel ---- etc., complete with all lead Each546.34546.348.0FalseNoneNoneFalseNoneFalse4370.720
3622968131621NonePWD SR 19-20,6.17.16Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 300 sqmm Long Barrel ---- etc., complete with all lead Each739.86739.8624.0FalseNoneNoneFalseNoneFalse17756.640
3622969131621NoneV-6,12.59.1Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary Gl bolts/nuts and washer or welding as required 150x50mm ---- etc., complete with all lead Mtr562.73562.73500.0FalseNoneNoneFalseNoneFalse281365.00
3622970131621NoneV-6,12.59.3Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary Gl bolts/nuts and washer or welding as required 450x50mm ---- etc., complete with all lead Mtr1109.661109.6650.0FalseNoneNoneFalseNoneFalse55483.00
3622971131621NoneV-6,12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all lead No4266.054266.0540.0FalseNoneNoneFalseNoneFalse170642.00
3622972131621NoneV-6,12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all lead Mtr99.6699.66200.0FalseNoneNoneFalseNoneFalse19932.00
3622973131621NoneV-6,12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete with all lead Mtr155.57155.57350.0FalseNoneNoneFalseNoneFalse54449.50
3622974131621NoneV-6,12.58.4Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm GI strip ---- etc., complete with all lead Mtr219.99219.9930.0FalseNoneNoneFalseNoneFalse6599.70
3622975131621NoneV-6,12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600 X 600 X 3 mm GI plate. ---- etc., complete with all lead Mtr1063.481063.484.0FalseNoneNoneFalseNoneFalse4253.920
3622976131621NoneV-6,12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper strip ---- etc., complete with all lead Mtr692.78692.78110.0FalseNoneNoneFalseNoneFalse76205.80
3622977131621NoneV-6,12.58.8Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm Copper strip ---- etc., complete with all lead Mtr1336.941336.9480.0FalseNoneNoneFalseNoneFalse106955.20
3622978131621NoneV-6,12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete with all lead Mtr1996.91996.9220.0FalseNoneNoneFalseNoneFalse439318.00
3622979131621NoneV-6,12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 600x600x3mm Copper plate ---- etc., complete with all lead Each9019.489019.4832.0FalseNoneNoneFalseNoneFalse288623.360
3622980131621NoneQtn RateSupply and installation of Bedded Panel with 4 no's 6 amps sockets and 2 no's 16 amps sockets with switches and 6 watt LED light fixtures & Provision for 4Nos gas pipeline sockets. ---- etc., complete with all lead Each10330.910330.915.0FalseNoneNoneFalseNoneFalse154963.50
3622981131621NoneV-6,11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V at 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc., complete with all lead Each1075.631075.63154.0FalseNoneNoneFalseNoneFalse165647.020
3622982131621NoneV-6,11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V at 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc., complete with all lead Each1609.191609.1914.0FalseNoneNoneFalseNoneFalse22528.660
3622983131621NoneV-6,11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V at 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete with all lead Each838.63838.63549.0FalseNoneNoneFalseNoneFalse460407.870
3622984131621NoneV-6,11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead Each181.09181.0943.0FalseNoneNoneFalseNoneFalse7786.870
3622985131621NoneV-6,11.11.5Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete with all lead Each326.94326.94153.0FalseNoneNoneFalseNoneFalse50021.820
3622986131621NoneV-6,11.6.3Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' - 34 -36watt ---- etc., complete with all lead Each5533.725533.7286.0FalseNoneNoneFalseNoneFalse475899.920
3622987131621NoneV-6,11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70watts ---- etc., complete with all lead No7282.687282.6821.0FalseNoneNoneFalseNoneFalse152936.280
3622988131621NoneV-6,6.1Supplying exhaust fan of 1440 RPM of 300mm 12" size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead Each1813.381813.3841.0FalseNoneNoneFalseNoneFalse74348.580
3622989131621NoneV-6,6.2.2Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 15" Sweep 450mm ---- etc., complete with all lead Each5014.745014.746.0FalseNoneNoneFalseNoneFalse30088.440
3622990131621NoneV-6,6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 laggingmin, Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms 2M Ohms, Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. BLDC fans 48" Sweep 5 Star 1200 mm ---- etc., complete with all lead Each3253.633253.63268.0FalseNoneNoneFalseNoneFalse871972.840
3622991131621NoneV-6,6.5.1Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply. 300mm Sweep ---- etc., complete with all lead Each3028.783028.7822.0FalseNoneNoneFalseNoneFalse66633.160
3622992131621NoneV-6,12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all lead Each76.5776.57202.0FalseNoneNoneFalseNoneFalse15467.140
3622993131621NoneV-6,13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all lead Each148.28148.28839.0FalseNoneNoneFalseNoneFalse124406.920
3622994131621NoneV-6,13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead Each382.85382.85290.0FalseNoneNoneFalseNoneFalse111026.50
3622995131621NoneV-6,13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead Each859.29859.2949.0FalseNoneNoneFalseNoneFalse42105.210
3622996131621NoneV-6,13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead Each1775.71775.732.0FalseNoneNoneFalseNoneFalse56822.40
3622997131621NoneV-6,13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead Each196.89196.8942.0FalseNoneNoneFalseNoneFalse8269.380
3622998131621NoneV-6,12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead Each298.99298.9921.0FalseNoneNoneFalseNoneFalse6278.790
3622999131621NoneV-6,5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead Sq CM0.610.611666000.0FalseNoneNoneFalseNoneFalse1016260.00
3623000131621NoneV-6,5.40.5Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 1000 A double run of 4 x 60 x 10 mm Aluminium Strips ---- etc., complete with all lead Mtr12858.9312858.9325.0FalseNoneNoneFalseNoneFalse321473.250
3623001131621NoneV-6,5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm ---- etc., complete with all lead Mtr674.55674.5542.0FalseNoneNoneFalseNoneFalse28331.10
3623002131621NoneV-6,5.41.5Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x150x75x6mm C channel ---- etc., complete with all lead Mtr1125.461125.4642.0FalseNoneNoneFalseNoneFalse47269.320
3623003131621NoneV-6,5.15.10Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA125Amps 25kA ---- etc., complete with all lead Each12568.4512568.456.0FalseNoneNoneFalseNoneFalse75410.70
3623004131621NoneV-6,5.15.17Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Therm IS-13947. Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE320-400Amps 50kA ---- etc., complete with all lead Each36596.9136596.912.0FalseNoneNoneFalseNoneFalse73193.820
3623005131621NoneV-6,5.15.20Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Therm IS-13947. Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE700-800Amps 50kA ---- etc., complete with all lead Each60648.4660648.462.0FalseNoneNoneFalseNoneFalse121296.920
3623006131621NoneQtn RateSupply and fixing of 800Amps fully Enclosed Automatic Transfer Switch ATS Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,.Adjustable Time Delay0.1sec to 3 hours,.Double-Break Contact System offering High Short-time Withstand Icw,.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 Volts ---- etc., complete with all lead Each112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3623007131621NoneV-6,5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board ---- etc., complete with all lead Each11248.5311248.532.0FalseNoneNoneFalseNoneFalse22497.060
3623008131621NoneV-6,5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all lead Each11321.4511321.4512.0FalseNoneNoneFalseNoneFalse135857.40
3623009131621NoneV-6,5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all lead Each625.93625.9351.0FalseNoneNoneFalseNoneFalse31922.430
3623010131621NoneV-6,5.34Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all lead Each683.05683.0532.0FalseNoneNoneFalseNoneFalse21857.60
3623011131621NoneV-6,5.16Suppiying and fixing of Shunt trip suitable for MCCB.CBCT ---- etc., complete with all lead Each2069.832069.832.0FalseNoneNoneFalseNoneFalse4139.660
3623012131621NoneV-6,5.36Supplying,fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer ---- etc., complete with all lead Each1020.941020.9412.0FalseNoneNoneFalseNoneFalse12251.280
3623013131621NoneV-6,5.40.3Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 400Amps 4x50x10mm Aluminum Strips ---- etc., complete with all lead Mtr5402.455402.455.0FalseNoneNoneFalseNoneFalse27012.250
3623014131621NoneV-6,5.41.2Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x50x6mm ---- etc., complete with all lead Mtr480.08480.0810.0FalseNoneNoneFalseNoneFalse4800.80
3623015131621NoneV-6,5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead Mtr918.84918.84103.0FalseNoneNoneFalseNoneFalse94640.520
3623016131621NoneV-6,5.39Supplying, fixing and wiring Automatic Power Factor controller fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three place LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect I disconnect banks, with automatic recognition or with standard programs. ---- etc., complete with all lead Each26301.2626301.261.0FalseNoneNoneFalseNoneFalse26301.260
3623017131621NoneV-6,5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete with all lead Kvar583.39583.39150.0FalseNoneNoneFalseNoneFalse87508.50
3623018131621NoneV-6,5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete with all lead Each1567.871567.873.0FalseNoneNoneFalseNoneFalse4703.610
3623019131621NoneV-6,5.13.2Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 40 Amps ---- etc., complete with all lead Each2744.372744.374.0FalseNoneNoneFalseNoneFalse10977.480
3623020131621NoneV-6,5.40.2Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete with all lead Mtr4174.94174.927.0FalseNoneNoneFalseNoneFalse112722.30
3623021131621NoneV-6,5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all lead Mtr370.7370.793.0FalseNoneNoneFalseNoneFalse34475.10
3623022131621NoneV-6,5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete with all lead Mtr2995.962995.9626.0FalseNoneNoneFalseNoneFalse77894.960
3623023131621NoneV-6,5.2.1Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired ajter fixing to the existing wooden board for motor Upto 12.5 HP ---- etc., complete with all lead Each9060.819060.816.0FalseNoneNoneFalseNoneFalse54364.860
3623024131621NoneQtn RateSTREET LIGHTING PANEL-Fabricating, Supplying & Mounting M.S. Box made out of 16 SWG of size 700x750x220mm suitable for floor / wall mounting, fully weather proof with provision for better heat desipation, with two chambers & window for energy meter, provided with hinged front cover, two inside doors, with tamper proof locking arrangments, suitable size clamps with necessary cable entry pipe with gland and box should be finished with two coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. The box should be mounted on M.S.angle iron of size 40x40x6mm total length 4.7 mtr with 1:2:4 concreting 0.25x0.75x0.9 mtr including coping. provision for housing 3 phase energy meter, suitable size bus bar, 100 A cut out 3 Nos, with timer 3-120sec & contactorc 60-70Amps, 63 A MCB TPN 1 No, 2 Nos 32 A TPN MCB on 4mm thick hylum sheet, wiring with suitable size copper wire & lugs. The box should be earthed with pipe type earthing. AS PER PWD SR ---- etc., complete with all lead Set35400.035400.01.0FalseNoneNoneFalseNoneFalse35400.00
3623025131621NoneV-6,4.1.1Fabricating, supplying and erecting swaged tubular pole of height …Mtr having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the poleas per IS and 40mm dia GI / flexible PVC pipe of 1 mtr length fitted to the heavy gauge polycarbonate control box including 5way connector of size 167x125x82mm for 7.5M pole/200x160x98mm for remaining length of pole with front opening cover, with locking arrangements and suitable capacity MCB / DP switch, The pole shall be erected in cement concrete work 1:2:4 including excavation and refilling of planting depth of the pole to the ground level and the coping CC shall be up to 0.6M above ground level as per IS 2713 - 7. Erection of heavy duty pole on Footpath / median 9Mt 5Mt Hb,165.1mm dia 4.85mm thick x2M Hm, 139.7mm dia 4.50mm thick x 2M Ht,114.3mm dia 3.65mm thick as per IS 410 SP 32 ---- etc., complete with all lead Each18838.718838.710.0FalseNoneNoneFalseNoneFalse188387.00
3623026131621NoneV-6,11.12.2Supply of LED Bollard light fitting of ...W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition. 8W 1 Mtr Height ---- etc., complete with all lead Each5504.495504.495.0FalseNoneNoneFalseNoneFalse27522.450
3623027131621NoneV-6,32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete with all lead Km96298.5796298.570.25FalseNoneNoneFalseNoneFalse24074.64250
3623028131621NoneV-6,31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete with all lead Km25384.8425384.841.25FalseNoneNoneFalseNoneFalse31731.050
3623029131621NoneV-6,6.7.1Supplying of…TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube.High wall chorded/cordless suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 Star 1 ton capacity ---- etc., complete with all lead Each50689.4750689.475.0FalseNoneNoneFalseNoneFalse253447.350
3623030131621NoneV-6,6.7.3Supplying of…TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube.High wall chorded/cordless suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 Star 2 ton capacity ---- etc., complete with all lead Each65689.9465689.9412.0FalseNoneNoneFalseNoneFalse788279.280
3623031131621NoneV-6,6.7.2Supplying of…TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube.High wall chorded/cordless suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 Star 1.5 ton capacity ---- etc., complete with all lead Each57953.9257953.925.0FalseNoneNoneFalseNoneFalse289769.60
3623032131621NoneV-6,6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 ton split/cassette type A/C. ---- etc., complete with all lead Each3858.93858.922.0FalseNoneNoneFalseNoneFalse84895.80
3623033131621NoneV-6,9.1.1Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v in put and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. 3 KVA Capacity ---- etc., complete with all lead Each5824.25824.210.0FalseNoneNoneFalseNoneFalse58242.00
3623034131621NoneV-6,9.1.2Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v in put and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. 4 KVA Capacity ---- etc., complete with all lead Each5824.25824.212.0FalseNoneNoneFalseNoneFalse69890.40
3623035131621NoneV-6,7.4.3Supplying, installation, testing and commissioning of solar hot water heater comprising of high quality Evacuated Glass Tube EGT with absorber coating collector of size 58 x 1800 mm. Inner tank Material-Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode 300 Liter capacity- 29 nos Tubes ---- etc., complete with all lead Each64895.0764895.078.0FalseNoneNoneFalseNoneFalse519160.560
3623036131621NoneV-6 BSR,31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete with all lead Km37846.3437846.340.1FalseNoneNoneFalseNoneFalse3784.6340
3623037131621NoneV-6 ,5.14.9Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 100Amps 25kA ---- etc., complete with all lead Each10315.110315.14.0FalseNoneNoneFalseNoneFalse41260.40
3623038131621NoneV-6,13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete with all lead No58.3458.3430.0FalseNoneNoneFalseNoneFalse1750.20
3623039131621NoneV-6,2.16Supply of Spiral Earth Electrode ---- etc., complete with all lead No290.48290.4813.0FalseNoneNoneFalseNoneFalse3776.240
3623040131621NoneV-6,68.17Supply and fixing of Caution/Danger Board ---- etc., complete with all lead No182.31182.317.0FalseNoneNoneFalseNoneFalse1276.170
3623041131621NoneV-6,24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete with all lead Set25839.425839.42.0FalseNoneNoneFalseNoneFalse51678.80
3623042131621NoneV-6,24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete with all lead No7378.697378.692.0FalseNoneNoneFalseNoneFalse14757.380
3623043131621NoneV-6,25.01Supply of DOLO Cut Out ---- etc., complete with all lead Set7140.487140.482.0FalseNoneNoneFalseNoneFalse14280.960
3623044131621NoneV-6,13.01Erection of DOLO Cut Out ---- etc., complete with all lead Set288.05288.052.0FalseNoneNoneFalseNoneFalse576.10
3623045131621NoneV-6,13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180Part-1:2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete with all lead Each206940.08206940.081.0FalseNoneNoneFalseNoneFalse206940.080
3623046131621NoneV-6,45.07Supply & Making of 11KV E Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete with all lead Set4943.034943.038.0FalseNoneNoneFalseNoneFalse39544.240
3623047131621NoneV-6,45.04Supply & Making of 11KV E Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete with all lead Set3813.933813.934.0FalseNoneNoneFalseNoneFalse15255.720
3623048131621NoneV-6,36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 Part-2 Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, 54 GI Wires - 2.5 mm Dia ---- etc., complete with all lead Km1081300.061081300.060.2FalseNoneNoneFalseNoneFalse216260.0120
3623049131621NoneV-6,38Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete with all lead Sqm1199.61199.6300.0FalseNoneNoneFalseNoneFalse359880.00
3623050131621NoneV-6,5.15.15Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete with all lead Each28616.5928616.591.0FalseNoneNoneFalseNoneFalse28616.590
3623051131621NoneV-6,3.6.11TV/Telephone socket ---- etc., complete with all lead Each189.6189.626.0FalseNoneNoneFalseNoneFalse4929.60
3623052131621NoneV-6,5.19.8Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure II - Double Door 8 Way SP & N ---- etc., complete with all lead Each2253.352253.353.0FalseNoneNoneFalseNoneFalse6760.050
3623053131621NonePWD SR 19-20,6.11.1Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class metal only 19/20mm ---- etc., complete with all lead Each80.2480.2412.0FalseNoneNoneFalseNoneFalse962.880
3623054131621NoneV-6,8.2.2Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable. ---- etc., complete with all lead Mtr25.5225.522200.0FalseNoneNoneFalseNoneFalse56144.00
3623055131621NoneV-6,8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. ---- etc., complete with all lead Mtr53.4853.48950.0FalseNoneNoneFalseNoneFalse50806.00
3623056131621NoneV-6,11.11.7Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete with all lead Each517.76517.7610.0FalseNoneNoneFalseNoneFalse5177.60
3623057131621NoneV-6,12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead Each63.263.212.0FalseNoneNoneFalseNoneFalse758.40
3623058131621NoneV-6,11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete with all lead No2947.352947.356.0FalseNoneNoneFalseNoneFalse17684.10
3623059131621NoneV-6,5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete with all lead Each292.91292.9110.0FalseNoneNoneFalseNoneFalse2929.10
3623060131621NoneV-6,5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers63Amps ---- etc., complete with all lead Each487.38487.385.0FalseNoneNoneFalseNoneFalse2436.90
3623061131621NoneV-6,5.3Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead Each1677.251677.259.0FalseNoneNoneFalseNoneFalse15095.250
3623062131621NoneV-6,7.1.3Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete with all lead Each12448.1312448.136.0FalseNoneNoneFalseNoneFalse74688.780
3623063131621NoneV-6,14.4.6Design, supplying, erecting testing and commissioning of - 20Passenger/ Bed-cum-passenger hospital lift3 stops/3 Opening with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665/2016 with latest amendments part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code NEC, NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. ---- etc., complete with all lead Each3504618.033504618.032.0FalseNoneNoneFalseNoneFalse7009236.060
3623064131621NoneQtn RateSupply, Installation Testing and commissioning of double convertsion, DSP Based, True on line 2 x20KVA UPS system with 415V +/- 15% V,50Hz,3Ph Input & 415V+/-1%, 50 Hz ,3Ph Output, With Output 0.9 PF, working on 16 Bit microprocessor Architecture,Isolation transformers, RS 232 ports, monitoring software , O/L, SC. protections & self diagnostic features, LCD Display Panel for Functions & all parameters, complying with IEC standards. Convertors, Invertors & Battery Charger shall utilize PWM technology with IGBT. Battery Back up time of 30 minutes back up on 40kva load with required VRLA SMF individual Battery bank System65AH-64 Nos housed in suitable Cabinet /Rack, Static ByPass, complete with Internal wiring & all accessories to be provided. The System shall have in-built P.F.correction & shall ensure THD as per latest International standards. The efficiency of UPS shall be 96% or more. ---- etc., complete with all lead Each1062000.01062000.01.0FalseNoneNoneFalseNoneFalse1062000.00
3623065131621NoneV-6,3.6.13RJ45/ I.O. outlet Cat 6 ---- etc., complete with all lead Each409.59409.5970.0FalseNoneNoneFalseNoneFalse28671.30
3623066131621NoneV-6,3.6.12Telephone socket ---- etc., complete with all lead Each189.6189.650.0FalseNoneNoneFalseNoneFalse9480.00
3623067131621NoneV-6,8.1Supplying and drawing UTP-CAT 6E LAN cable. ---- etc., complete with all lead Mtr46.1946.199800.0FalseNoneNoneFalseNoneFalse452662.00
3623068131621NoneV-6,8.10.1Supplying & Fixing of I/O Socket with back box Single I/O ---- etc., complete with all lead Each595.55595.5570.0FalseNoneNoneFalseNoneFalse41688.50
3623069131621NoneV-6,8.4.3Supplying & Fixing of switch mounting rack with power manager & Cable manager as per standard specification 9U with 450mm depth ---- etc., complete with all lead Each10301.7310301.732.0FalseNoneNoneFalseNoneFalse20603.460
3623070131621NoneV-6,8.9.5Supplying fixing of Network Switches. 24 port 10/100 Switch ---- etc., complete with all lead Each5712.385712.384.0FalseNoneNoneFalseNoneFalse22849.520
3623071131621NoneV-6,8.11.2Supplying & fixing of ..mtrs. Cat 6Patch Cable. 2Mtr ---- etc., complete with all lead Each312.36312.3670.0FalseNoneNoneFalseNoneFalse21865.20
3623072131621NoneV-6,8.12.3Supplying & Fixing of Patch panel for Lan Cabling. 16 Port 10/100 patch panel ---- etc., complete with all lead Each3706.973706.972.0FalseNoneNoneFalseNoneFalse7413.940
3623073131621NoneV-6,8.2.5Supplying and drawing PVC flexible 5 pair telepone unarmoured tinned copper cable. ---- etc., complete with all lead Mtr55.9155.91100.0FalseNoneNoneFalseNoneFalse5591.00
3623074131621NoneV-6,8.2.6Supplying and drawing PVC flexible 10 pair telepone unarmoured tinned copper cable. ---- etc., complete with all lead Mtr98.4598.45150.0FalseNoneNoneFalseNoneFalse14767.50
3623075131621NoneV-6,8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 20 Pair ---- etc., complete with all lead Each465.5465.53.0FalseNoneNoneFalseNoneFalse1396.50
3623076131621NoneV-6,8.13.4Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 50 Pair ---- etc., complete with all lead Each766.92766.921.0FalseNoneNoneFalseNoneFalse766.920
3623077131621NoneQtn RateEPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , IP READY,based on Linux/GRUB compliant, integrated Software for multiTasking for Hospitality Services including Billing ,comprising of items as below but not limited to them. Expanadable upto 50 Ports Providing PRI cards for Trunk lines / for tie line with reqd.software 16Analog Trunk Lines 4 Digital Extensions 20 Analogue Extensions Expandable up to 50 In-Built Voicemail 4 Port & 80 Min LAN Connectivity Embedded WELCOME MESSAGE Least Cost Routing Personal Assistant Music on Hold . ---- etc., complete with all lead Nos141600.0141600.01.0FalseNoneNoneFalseNoneFalse141600.00
3623078131621NoneQtn RateTELEPHONES Analog push button telephone with Caller ID, flash and radial ---- etc., complete with all lead Nos2124.02124.050.0FalseNoneNoneFalseNoneFalse106200.00
3623079131621NoneQtn RateSupply, Installation, Testing and Commissioning of Line Interface Unit-6 Port LIU with Coupler and Connector SM Type ---- etc., complete with all lead Nos2125.182125.182.0FalseNoneNoneFalseNoneFalse4250.360
3623080131621NoneQtn RateSupply, Installation, Testing and Commissioning of 6-core OFC - Armoured outdoor cable SM ---- etc., complete with all lead Mtr115.64115.64200.0FalseNoneNoneFalseNoneFalse23128.00
3623081131621NoneQtn RateIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x10802MP,2.7mm13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4IRon,30M IR distance, BLC/HLC/WDR120db,min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets. ---- etc., complete with all lead Each23836.023836.018.0FalseNoneNoneFalseNoneFalse429048.00
3623082131621NoneQtn RateIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x10802MP,2.7mm13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4IRon,60M IR distance, BLC/HLC/WDR120db,min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets. ---- etc., complete with all lead Each25606.025606.05.0FalseNoneNoneFalseNoneFalse128030.00
3623083131621NoneQtn RateSupplying, installation, testing and commissioning of SITC of complete 32 channel 4K embedded network video recorder,up to 12MP4K resolution live view,preview,and play back,full POE Support for up to 16 channels,internal storage supports 8HDDs expandable up to 64TB 8TB each,operating temperatures-10 degree C and 55 degree C,UL,CE,FCC. ---- etc., complete with all lead Each271400.0271400.01.0FalseNoneNoneFalseNoneFalse271400.00
3623084131621NoneQtn RateSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete with all lead Each17110.017110.06.0FalseNoneNoneFalseNoneFalse102660.00
3623085131621NoneQtn RateSupply and Installation of 16 Port L2 Managed Poe Switch The rate shall include all mounting accessories complete as required ---- etc., complete with all lead Each47495.047495.02.0FalseNoneNoneFalseNoneFalse94990.00
3623086131621NoneQtn RateSupply and Installation of I/Os ---- etc., complete with all lead Each147.5147.523.0FalseNoneNoneFalseNoneFalse3392.50
3623087131621NoneQtn RateSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete with all lead Each265.5265.530.0FalseNoneNoneFalseNoneFalse7965.00
3623088131621NoneQtn RateSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete with all lead Each336.3336.330.0FalseNoneNoneFalseNoneFalse10089.00
3623089131621NoneQtn RateSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete with all lead Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3623090131621NoneV-6,8.12.2Supplying & Fixing of Patch panel for LAN cabling .24 Port 10/100 patch panel ---- etc., complete with all lead Each4983.144983.146.0FalseNoneNoneFalseNoneFalse29898.840
3623091131621NoneV-6,8.4.4Supplying & Fixing of switch mounting rack with power manager & Cable manager 12U with 450mm depth ---- etc., complete with all lead Each10738.0610738.062.0FalseNoneNoneFalseNoneFalse21476.120
3623092131621NoneQtn RateThe Scope of work is Supply,istallation, Testing for T.V. System with following Items & components in Rooms & other Specific Areas. It also covers co-ordination with T.V service provider for completeness & usage of the Items /components erected by Vendor.Booster amplifier. ---- etc., complete with all lead Each3540.03540.04.0FalseNoneNoneFalseNoneFalse14160.00
3623093131621NoneQtn RateThe Scope of work is Supply,istallation, Testing for T.V. System with following Items & components in Rooms & other Specific Areas. It also covers co-ordination with T.V service provider for completeness & usage of the Items /components erected by Vendor. 3 way splitter. ---- etc., complete with all lead Each236.0236.06.0FalseNoneNoneFalseNoneFalse1416.00
3623094131621NoneQtn RateSupply, installation, testing and commissioning of 'The Bedside call unit shall be mounted on the head boards where there are patient headboards or on the walls where it can be implemented within the system.'The Bedside call unit shall be 2 input\output ports for RJ45 Endings for cabling in a chain with overdoor lights and other call units and eventually to one zone controller. 'On the standard bedside call unit front side there shall be: 'An "End Call" Button with a green tick mark symbol.'Reassurance backlight in order to give visual information about call ststus.'Continous backlight for easy visibility of the unit at night.'Pressing on the end call button ends the call and turns the assigned overdoor light to green. IP System controller logs the event as "Presence"'Pressing the end call button for the second time ends the "presence" and turns off the assigned overdoor light.'The Bedside Call Unit shall made from noninflammable PC-ABS-FR Materials.'It can be used individually as a call button where patient handset is not needed. Other wise, its connection with the patient handset shall be easily established ny the connecting via RJ45 on its front side.'A Nurse call shall be initated via the patient handset or the bedside call unit. These two buttons shall be accepted by the system as equivalent. In the event that these buttons are pressed.'If the unit is ablee to transmit the call to the zone controller, the LED on the unit shall flash with 1.0 second intervals, call transmission information shall be audibly notified to the patient.'If there is an error in the call transmission, a continuous red light showing error status shall only stop when the call termination button is pressed, subsequent presses of the button shall trigger an audio alert each time.'Its connection shall be made with cat 6 UTP Cable RJ45 of B Standard.'This device shall be powered by the Zone Controller. ---- etc., complete with all lead Nos4130.04130.0100.0FalseNoneNoneFalseNoneFalse413000.00
3623095131621NoneQtn RateSupply, installation, testing and commissioning of PATIENT HANDSET BASIC.This Handset will be used in the locations that are connected to the system by a zone controller.'It Shall be ergonomically suitable to be handheld.'It shall be connected to the bedside call unit with an independent cable.'on its front side there shall be 'A "start Call" Button with red nurse symbol.'Reassurance LED light in order to give visual information about the call status.Continues LED Light for easy visibility at night.'Call Initation and error notification procedures is the same as bedside call unit except audio alerts are always issued by the bedside call unit its call initiation button and back light works in parallel with the one on the bedside call unit.It shall have an easily cleanable surface that dose not promote bacterial growth.Patient handset shall be made from non inflammable PC-ABS-FR Materials. ---- etc., complete with all lead Nos5900.05900.0100.0FalseNoneNoneFalseNoneFalse590000.00
3623096131621NoneQtn RateSupply, installation, testing and commissioning of CODE BLIE CALL UNIT;- The Code Blue Call Unit shall be mounted on headboards where there are patient headboards or on the walls where it can be implemented within the system. The Code Blue Call Unit has 2 Input/Output ports for RJ45 endings for cabling in a chain with Over Door Lights and other call units and eventually to one Zone Controller. On the Code Blue call unit front side there shall be; A “start code blue” button with a blue medicine symbol. Pressing the button initiates a Code Blue event, turning on the assigned Overdoor lights to Blue. An “end code blue” button with a green tick mark symbol. Pressing the Button shall cancel the Code blue alarm turning the assigned Overdoor lights. Reassurance backlight in order to give visual information about the call status. Continuous backlight for easy visibility of the unit at night. The Code Blue Call Unit shall be made from nonflammable PC-ABS-FR materials. If the unit is able to transmit the call to the zone controller, the LED on the unit shall flash with 1.0-second intervals. Call transmission information shall be audibly notified to the patient. If there is an error in call transmission, a continuous red light showing the error status shall only stop when the call termination button is pressed or room control connection is made. Subsequent presses of the button shall trigger an audio alert each time. Its connection shall be made with Cat 6 UTP cable and RJ45 of B standard. ---- etc., complete with all lead Nos4071.04071.0100.0FalseNoneNoneFalseNoneFalse407100.00
3623097131621NoneQtn RateSupply, installation, testing and commissioning of PULL-CORD CALL UNITWC\Bathroom-The Pull-cord call unit has 2 input\output ports for RJ45 Ending for cabling in a chain with overdoor lights and other call units and eventually to one zone controller. on its front side there shall be A pull-code call unit with customizable length with minimum 1.5 meters to serve as a call-code.A call termination button indicated by a green tick Mark Symbol.Its Connection shall be made with CAT6 UTP cable and RJ45 of B standard.A priority WC Emergency call shall start when the cord is pulled.This Device will be used in the locations that are connected to the system by a zone controller. ---- etc., complete with all lead Nos4189.04189.020.0FalseNoneNoneFalseNoneFalse83780.00
3623098131621NoneQtn RateSupply, installation, testing and commissioning of 'Over Door Light shall use environmentally friendly LEDs.'It shall consist of Red, Green, Blue, white, Pink Colored Warning Light.'In Normal Condition, no light shall be lit, if the patient makes nurse call, Red Light shall be Lit with in 0.5 Seconds. After all nurse call, when the nurse presses the green presence button on the call unit, the light of the over door light will return green.'In code blue, the blue light shall be lit.'The outer casing of the over door light shall be made of nonflammble PC-ABS-FR Materials.'Over door light shall have 2 input\output ports for RJ45 ending for cabling in a chain with call units on one of the communication lines of the zone controller. Alternativley, it connects to the RCU in private & semi private rooms.'Its connection shall be made with cat 6 UTP Cable RJ45 of B Standard.'This device shall be powered by the Zone Controller or black colored communication ports of RCU unit to which it is connected. It shall not require additional energy supply. ---- etc., complete with all lead Nos11463.711463.720.0FalseNoneNoneFalseNoneFalse229274.00
3623099131621NoneQtn RateSupply, installation, testing and commissioning of 'IP BASED NURSE CALL SYSTEM Supply, Installation, testing and commissioning of the IP based Nurse Call System based on the following components including but not restricted to gold plated connecting leads, connectors, patch cables, jumpers, nuts, screws, bolts, mounting plates, cover plates, back boxes etc., 'Shall be in accordance with International guidelines and shall be in such a way that the most effective communication between Patient, Nursing Staff, Doctor & management staff can be provided in the least possible time. 'System Operation\Ward Nurse Station;-'The ward Nurse Station Shall be used in the location that are connected to the system by a zone controller. It is placed in each multi bed ward areas at the nurse station overlooking the patent beds.'The ward Nurse station Shall have a minimum 10 Inch touchscreen and include its own integrated handsfree voice communication with other Nurse control Panels.'The Nurse control panel may be used to monitor the status of every assigned call points, call and alarm status.the screen will show active calls and emergency code with top to bottom priority, highest priority active calls is on top and longest awaiting calls within same call type having more priority than same type.'The origin room and the bed information of all active nurse calls, code blue calls shall be shown with an audiovisual alert along with the call type.'onscreen call points shall have notification of relevant icons, colors, and tones according to their call status as well as time the call started and time passed since.'call shall be shown real time. Each activity will be send to IP System Controller for logging enabling later inspection and reporting.'Time stamp and error logs for situations when the energy supply of the panel is cut or there is no network connection shall be recorded on the IP System controller.'Emergency codeblue, Red, pink, and white shall be initiated from the touch screen. ---- etc., complete with all lead Nos95138.6895138.686.0FalseNoneNoneFalseNoneFalse570832.080
3623100131621NoneQtn RateSupply, installation, testing and commissioning of IP ZONE CONTROLLER This is the main node device used to network the Nurse call system devices to each other for areas are not private or semi-private rooms and do not have item 3.2RCU. It is to be used for multi bed wards areas in a single open soace with a nurse desk overlooking the assigned patient beds.Each zone controller has 2 communication ports which support chains of up to 24 calls initiation devices each,and up to as many over door lights as the number of the call initiation devices, for a total maximum support of 48 call devices.The connection shall be made with cat 6 UTP Cable and RJ45 of B Standard. Toatl cable length from the Zone Controller to the last call device Cannot be longer than 500 meters for each communication line oneach communication port.Zone controller shall have 2 power injectors to be included with the device to be used for injecting 12V power to be used on each communication line. Each power injector has 2 RJ% Ports to be connected at suitable location to prevent voltage drops on the lines.Each Power injector require 110-240 V Power.There shall not be any limits to the number of zone controllers that can be used in a nurse call system, they may be placed in the network switch, its connection shall be made with cat 6 UTP cable and RJ% of B Standard.The zone controller shall have 1 port for 110-240 V Power.'The zone controller must be configurable from the IP System Controller. ---- etc., complete with all lead Nos85388.3485388.346.0FalseNoneNoneFalseNoneFalse512330.040
3623101131621NoneV-6,6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete with all lead No105.74105.7412.0FalseNoneNoneFalseNoneFalse1268.880
3623102131621NoneV-6,1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete with all lead Set8600.178600.1710.0FalseNoneNoneFalseNoneFalse86001.70
3623103131621NoneV-6,2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete with all lead Set1352.741352.7410.0FalseNoneNoneFalseNoneFalse13527.40
3623104131621NoneV-6,2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL ---- etc., complete with all lead Set591.9591.96.0FalseNoneNoneFalseNoneFalse3551.40
3623105131621NoneV-6,5.03Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL ---- etc., complete with all lead Set312.36312.366.0FalseNoneNoneFalseNoneFalse1874.160
3623106131621NoneV-6,6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator 24 mm Dia FRP Rod ---- etc., complete with all lead No249.16249.1618.0FalseNoneNoneFalseNoneFalse4484.880
3623107131621NoneV-6,6.1Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete with all lead No226.06226.0618.0FalseNoneNoneFalseNoneFalse4069.080
3623108131621NoneV-6,6.08Supply and fixing of 15 Strain Insulator ---- etc., complete with all lead Set71.7171.714.0FalseNoneNoneFalseNoneFalse286.840
3623109131621NoneV-6,7.02Supply of Rabbit ACSR Conductor ---- etc., complete with all lead Km56192.856192.81.0FalseNoneNoneFalseNoneFalse56192.80
3623110131621NoneV-6,6.02Erection of Rabbit ACSR Conductor ---- etc., complete with all lead Km5300.365300.361.0FalseNoneNoneFalseNoneFalse5300.360
3623111131621NoneV-6,10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete with all lead No170.16170.1615.0FalseNoneNoneFalseNoneFalse2552.40
3623112131621NoneV-6,2.08Erection of Spiral Earth Electrode ---- etc., complete with all lead No113.03113.0313.0FalseNoneNoneFalseNoneFalse1469.390
3623113131621NoneV-6,4.02Supply of Anti Climbing Device 12 Mtr GI Barbed Wire ---- etc., complete with all lead Each108.17108.1710.0FalseNoneNoneFalseNoneFalse1081.70
3623114131621NoneV-6,5.09Erection of Anti Climbing Device 12 Mtr GI Barbed Wire ---- etc., complete with all lead Each51.0551.0510.0FalseNoneNoneFalseNoneFalse510.50
3623115131621NoneV-6,41.01Load Break Switch with Panel ---- etc., complete with all lead No89014.6889014.681.0FalseNoneNoneFalseNoneFalse89014.680
3623116131621NoneV-6,58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated as per revised Specification Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018 ---- etc., complete with all lead No295915.87295915.871.0FalseNoneNoneFalseNoneFalse295915.870
3623117131621NoneV-6,53.01CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 PortUNIDIRACTIONAL Used for HT Installation, LT Metering Cubicle 50-150 KW ---- etc., complete with all lead No23840.0723840.071.0FalseNoneNoneFalseNoneFalse23840.070
3623118131621NoneV-6,13.1Supply, erection, testing and commissioning of 500 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180Part-1:2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete with all lead Each1188649.051188649.051.0FalseNoneNoneFalseNoneFalse1188649.050
3623119131621NoneQtn RateSupplying, installing, testing and commissioning of 180KVA/144kw Diesel Generator set CPCB 4 norms with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer Hospital grade,Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf lag suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation max in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage 1 ph or 3 ph line to line and line to neutral voltage, Current 1 ph or 3 ph, kVA 3 ph and total, Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA at 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, (Item full specification refer document-1 Sl No-3) ---- etc., complete with all lead Set2224300.02224300.01.0FalseNoneNoneFalseNoneFalse2224300.00
3623120131621NoneV-6,10.2.5Supply, Erection, testing and commissioning of AMF panel suitable for .....KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....amps 4 pole contactor for alternator with thermal O/L relay,..... Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 180 KVA ---- etc., complete with all lead Each171727.51171727.511.0FalseNoneNoneFalseNoneFalse171727.510
3623121131621NoneQtn RateSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete with all lead m4779.04779.015.0FalseNoneNoneFalseNoneFalse71685.00
3623122131621NoneQtn RateSupply and installing of DG set stack using angular structure, channel, necessary nut and bolt and all required accessories for erecting exhaust pipe from 2 nos DG set and space provision for provinding exhaust pipe for 2 more DG set in future. The design of the stack with foundation shall be got approved before fabrication. The foundation for the stack shall be measured separately. ---- etc., complete with all lead Kg171.1171.1300.0FalseNoneNoneFalseNoneFalse51330.00
3623123131621NoneQtn RateSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete with all lead Mtr330.59330.59100.0FalseNoneNoneFalseNoneFalse33059.00
3623124131621NoneV-2,13.50.5WATER SUPPLY--Providing and fixing Unplasticised Polyvinyl Chloride uPVC pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines Ground Floor ---- etc., complete with all lead m369.48369.48124.0FalseNoneNoneFalseNoneFalse45815.520
3623125131621NoneV-2,13.50.6Providing and fixing Unplasticised Polyvinyl Chloride uPVC pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines Ground Floor ---- etc., complete with all lead m469.14469.1453.0FalseNoneNoneFalseNoneFalse24864.420
3623126131621NoneV-2,13.64.1Providing and fixing Sewer SWR pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. Internal drainage & Shaft Drainage 75mm nominal dia pipes Ground Floor ---- etc., complete with all lead m351.25351.25695.0FalseNoneNoneFalseNoneFalse244118.750
3623127131621NoneV-2,13.64.2Providing and fixing Sewer SWR pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. Internal drainage & Shaft Drainage 110mm nominal dia pipes Ground Floor ---- etc., complete with all lead m467.93467.93644.0FalseNoneNoneFalseNoneFalse301346.920
3623128131621NoneV-2,13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, i Single socketed pipes 75 mm diameter Ground Floor ---- etc., complete with all lead m239.43239.43158.0FalseNoneNoneFalseNoneFalse37829.940
3623129131621NoneV-2,13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, i Single socketed pipes 100 mm diameter Ground Floor ---- etc., complete with all lead m353.68353.68235.0FalseNoneNoneFalseNoneFalse83114.80
3623130131621NoneV-2,13.63Providing and fixing PVC S.W.R Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete Ground Floor ---- etc., complete with all lead Each296.56296.56142.0FalseNoneNoneFalseNoneFalse42111.520
3623131131621NoneV-2,14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Ground Floor ---- etc., complete with all lead Each1482.791482.7933.0FalseNoneNoneFalseNoneFalse48932.070
3623132131621NoneV-2,13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter Ground Floor ---- etc., complete with all lead Nos339.1339.113.0FalseNoneNoneFalseNoneFalse4408.30
3623133131621NoneV-2,14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. Ground Floor ---- etc., complete with all lead Each6760.056760.0513.0FalseNoneNoneFalseNoneFalse87880.650
3623134131621NoneV-2,14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g Ground Floor ---- etc., complete with all lead Each602.84602.8413.0FalseNoneNoneFalseNoneFalse7836.920
3623135131621NoneV-2,14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g Ground Floor ---- etc., complete with all lead Each176.23176.2313.0FalseNoneNoneFalseNoneFalse2290.990
3623136131621NoneV-2,13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 Ground Floor ---- etc., complete with all lead Each753.55753.55154.0FalseNoneNoneFalseNoneFalse116046.70
3623137131621NoneV-2,14.2.1Providing and fixing white vitreous china pedestal type water closet European type W.C. pan with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever, conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Ground Floor ---- etc., complete with all lead Each5880.115880.1129.0FalseNoneNoneFalseNoneFalse170523.190
3623138131621NoneV-2,20.44.2Providing & fixing White vitreous china water closet squatting pan Indian type along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.Orissa pattern W.C Pan of size 580x440 mm Ground Floor ---- etc., complete with all lead Each4311.024311.022.0FalseNoneNoneFalseNoneFalse8622.040
3623139131621NoneV-2,14.4.2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern Ground Floor ---- etc., complete with all lead Each8245.278245.278.0FalseNoneNoneFalseNoneFalse65962.160
3623140131621NoneV-2,14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Ground Floor ---- etc., complete with all lead Each6176.666176.666.0FalseNoneNoneFalseNoneFalse37059.960
3623141131621NoneV-2,14.10.1.1Providing and fixing Stainless Steel A ISI 304 18/8 kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mm Ground Floor ---- etc., complete with all lead Each6828.126828.1212.0FalseNoneNoneFalseNoneFalse81937.440
3623142131621NoneV-2,14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps Ground Floor ---- etc., complete with all lead Each3745.863745.8631.0FalseNoneNoneFalseNoneFalse116121.660
3623143131621NoneV-2,13.15Providing and fixing C.P. brass stop cock concealed of standard design and of approved make conforming to IS:8931. Ground Floor ---- etc., complete with all lead Nos881.17881.17133.0FalseNoneNoneFalseNoneFalse117195.610
3623144131621NoneV-2,14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. Ground Floor ---- etc., complete with all lead Each984.47984.47119.0FalseNoneNoneFalseNoneFalse117151.930
3623145131621NoneV-2,13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :30 cm length 15 mm nominal bore Ground Floor ---- etc., complete with all lead Each100.88100.88119.0FalseNoneNoneFalseNoneFalse12004.720
3623146131621NoneV-2,14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g Ground Floor ---- etc., complete with all lead Each371.91371.91119.0FalseNoneNoneFalseNoneFalse44257.290
3623147131621NoneV-2,13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g Ground Floor ---- etc., complete with all lead Nos77.7977.79228.0FalseNoneNoneFalseNoneFalse17736.120
3623148131621NoneV-2,13.2.1Providing and fixing brass bib cock of approved quality 15 mm nominal bore Ground Floor ---- etc., complete with all lead Nos347.6347.6111.0FalseNoneNoneFalseNoneFalse38583.60
3623149131621NoneV2,9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. Ground Floor ---- etc., complete with all lead Sqm5233.515233.5148.0FalseNoneNoneFalseNoneFalse251208.480
3623150131621NoneV-2,13.32.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes Ground Floor ---- etc., complete with all lead m375.56375.56141.0FalseNoneNoneFalseNoneFalse52953.960
3623151131621NoneV-2,13.32.2Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes Ground Floor ---- etc., complete with all lead m460.64460.64175.0FalseNoneNoneFalseNoneFalse80612.00
3623152131621NoneV-2,13.32.3Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Ground Floor ---- etc., complete with all lead m579.75579.75210.0FalseNoneNoneFalseNoneFalse121747.50
3623153131621NoneV-2,13.32.4Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Ground Floor ---- etc., complete with all lead m676.98676.98135.0FalseNoneNoneFalseNoneFalse91392.30
3623154131621NoneV-2,13.31.5Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 40 mm nominal dia Pipes Ground Floor ---- etc., complete with all lead m651.45651.45100.0FalseNoneNoneFalseNoneFalse65145.00
3623155131621NoneV-2,13.31.6Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 50 mm nominal dia Pipes Ground Floor ---- etc., complete with all lead m949.23949.2315.0FalseNoneNoneFalseNoneFalse14238.450
3623156131621NoneV-2,13.33.3Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes Ground Floor ---- etc., complete with all lead m359.76359.76300.0FalseNoneNoneFalseNoneFalse107928.00
3623157131621NoneV-2,13.33.4Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia pipes Ground Floor ---- etc., complete with all lead m452.13452.1380.0FalseNoneNoneFalseNoneFalse36170.40
3623158131621NoneV-2,13.33.5Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes Ground Floor ---- etc., complete with all lead m579.75579.75430.0FalseNoneNoneFalseNoneFalse249292.50
3623159131621NoneV-2,13.33.6Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal dia Pipes Ground Floor ---- etc., complete with all lead m876.3876.31405.0FalseNoneNoneFalseNoneFalse1231201.50
3623160131621NoneV-2,13.33.7Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 65 mm nominal dia Pipes Ground Floor ---- etc., complete with all lead m1701.561701.56675.0FalseNoneNoneFalseNoneFalse1148553.00
3623161131621NoneV-2,13.5.2Providing and fixing ball valve brass of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore Ground Floor ---- etc., complete with all lead Nos403.51403.5147.0FalseNoneNoneFalseNoneFalse18964.970
3623162131621NoneV-2,13.4.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality screwed end : 32 mm nominal bore Ground Floor ---- etc., complete with all lead Nos726.81726.8141.0FalseNoneNoneFalseNoneFalse29799.210
3623163131621NoneV-2,13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality screwed end : 40 mm nominal bore Ground Floor ---- etc., complete with all lead Nos853.21853.2140.0FalseNoneNoneFalseNoneFalse34128.40
3623164131621NoneV-2,13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality screwed end : 50 mm nominal bore Ground Floor ---- etc., complete with all lead Nos1039.171039.1724.0FalseNoneNoneFalseNoneFalse24940.080
3623165131621NoneV-2,13.4.5Providing and fixing Brass full way valve gate with C.I. wheel of approved quality screwed end : 65 mm nominal bore Ground Floor ---- etc., complete with all lead Nos1714.931714.9310.0FalseNoneNoneFalseNoneFalse17149.30
3623166131621NoneV-2,13.50.5Providing and fixing Unplasticised Polyvinyl Chloride uPVC pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines First Floor ---- etc., complete with all lead m373.18373.1896.0FalseNoneNoneFalseNoneFalse35825.280
3623167131621NoneV-2,13.50.6Providing and fixing Unplasticised Polyvinyl Chloride uPVC pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines First Floor ---- etc., complete with all lead m473.84473.8430.0FalseNoneNoneFalseNoneFalse14215.20
3623168131621NoneV-2,13.64.1Providing and fixing Sewer SWR pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. Internal drainage 75mm nominal dia pipes First Floor ---- etc., complete with all lead m354.76354.76600.0FalseNoneNoneFalseNoneFalse212856.00
3623169131621NoneV-2,13.64.2Providing and fixing Sewer SWR pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. Internal drainage 110mm nominal dia pipes First Floor ---- etc., complete with all lead m472.61472.61550.0FalseNoneNoneFalseNoneFalse259935.50
3623170131621NoneV-2,13.63Providing and fixing PVC S.W.R Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete First Floor ---- etc., complete with all lead Each299.52299.52120.0FalseNoneNoneFalseNoneFalse35942.40
3623171131621NoneV-2,14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. First Floor ---- etc., complete with all lead Each1497.621497.6242.0FalseNoneNoneFalseNoneFalse62900.040
3623172131621NoneV-2,13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter First Floor ---- etc., complete with all lead Nos342.49342.4924.0FalseNoneNoneFalseNoneFalse8219.760
3623173131621NoneV-2,14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. First Floor ---- etc., complete with all lead Each6827.666827.6624.0FalseNoneNoneFalseNoneFalse163863.840
3623174131621NoneV-2,14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g First Floor ---- etc., complete with all lead Each608.87608.8724.0FalseNoneNoneFalseNoneFalse14612.880
3623175131621NoneV-2,14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g First Floor ---- etc., complete with all lead Each178.0178.024.0FalseNoneNoneFalseNoneFalse4272.00
3623176131621NoneV-2,13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 First Floor ---- etc., complete with all lead Each761.08761.0895.0FalseNoneNoneFalseNoneFalse72302.60
3623177131621NoneV-2,14.2.1Providing and fixing white vitreous china pedestal type water closet European type W.C. pan with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever, conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid First Floor ---- etc., complete with all lead Each5938.915938.9128.0FalseNoneNoneFalseNoneFalse166289.480
3623178131621NoneV-2,20.44.2Providing & fixing White vitreous china water closet squatting pan Indian type along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.Orissa pattern W.C Pan of size 580x440 mm First Floor ---- etc., complete with all lead Each4354.134354.132.0FalseNoneNoneFalseNoneFalse8708.260
3623179131621NoneV-2,14.4.2Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern First Floor ---- etc., complete with all lead Each8327.738327.735.0FalseNoneNoneFalseNoneFalse41638.650
3623180131621NoneV-2,14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm First Floor ---- etc., complete with all lead Each6238.436238.436.0FalseNoneNoneFalseNoneFalse37430.580
3623181131621NoneV-2,14.10.1.1Providing and fixing Stainless Steel A ISI 304 18/8 kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mm First Floor ---- etc., complete with all lead Each6896.46896.42.0FalseNoneNoneFalseNoneFalse13792.80
3623182131621NoneV-2,14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps First Floor ---- etc., complete with all lead Each3783.323783.325.0FalseNoneNoneFalseNoneFalse18916.60
3623183131621NoneV-2,13.15Providing and fixing C.P. brass stop cock concealed of standard design and of approved make conforming to IS:8931. First Floor ---- etc., complete with all lead Nos889.98889.9882.0FalseNoneNoneFalseNoneFalse72978.360
3623184131621NoneV-2,14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. First Floor ---- etc., complete with all lead Each994.32994.3265.0FalseNoneNoneFalseNoneFalse64630.80
3623185131621NoneV-2,13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :30 cm length 15 mm nominal bore First Floor ---- etc., complete with all lead Each101.89101.8965.0FalseNoneNoneFalseNoneFalse6622.850
3623186131621NoneV-2,14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g First Floor ---- etc., complete with all lead Each375.63375.6365.0FalseNoneNoneFalseNoneFalse24415.950
3623187131621NoneV-2,13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g First Floor ---- etc., complete with all lead Nos78.5678.5674.0FalseNoneNoneFalseNoneFalse5813.440
3623188131621NoneV-2,13.2.1Providing and fixing brass bib cock of approved quality 15 mm nominal bore First Floor ---- etc., complete with all lead Nos351.08351.0868.0FalseNoneNoneFalseNoneFalse23873.440
3623189131621NoneV2,9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. First Floor ---- etc., complete with all lead Sqm5285.855285.8522.0FalseNoneNoneFalseNoneFalse116288.70
3623190131621NoneV-2,13.32.1Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes First Floor ---- etc., complete with all lead m379.31379.31100.0FalseNoneNoneFalseNoneFalse37931.00
3623191131621NoneV-2,13.32.2Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes First Floor ---- etc., complete with all lead m465.24465.24175.0FalseNoneNoneFalseNoneFalse81417.00
3623192131621NoneV-2,13.32.3Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes First Floor ---- etc., complete with all lead m585.54585.54250.0FalseNoneNoneFalseNoneFalse146385.00
3623193131621NoneV-2,13.32.4Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.32 mm nominal dia pipes First Floor ---- etc., complete with all lead m683.75683.75275.0FalseNoneNoneFalseNoneFalse188031.250
3623194131621NoneV-2,13.31.5Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 40 mm nominal dia Pipes First Floor ---- etc., complete with all lead m657.97657.97200.0FalseNoneNoneFalseNoneFalse131594.00
3623195131621NoneV-2,13.31.6Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 50 mm nominal dia Pipes First Floor ---- etc., complete with all lead m958.72958.7250.0FalseNoneNoneFalseNoneFalse47936.00
3623196131621NoneV-2,13.34Providing and placing on terrace at all floor levels polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. First Floor ---- etc., complete with all lead l11.0511.055000.0FalseNoneNoneFalseNoneFalse55250.00
3623197131621NoneQuotation RateProviding, fixing, testing and commissioning of Air Vent Cowel 110mm ---- etc., complete with all lead Nos219.48219.4840.0FalseNoneNoneFalseNoneFalse8779.20
3623198131621NoneQuotation RateProviding, fixing, testing and commissioning of Air Vent Cowel 75mm ---- etc., complete with all lead Nos189.98189.9835.0FalseNoneNoneFalseNoneFalse6649.30
3623199131621NoneQuotation RateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. Jaguar make or Equalent GF Toilet ---- etc., complete with all lead Nos9318.469318.4674.0FalseNoneNoneFalseNoneFalse689566.040
3623200131621NoneQuotation RateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit instant type CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. Jaguar make or Equalent GF Toilet ---- etc., complete with all lead Nos2183.02183.057.0FalseNoneNoneFalseNoneFalse124431.00
3623201131621NoneQuotation RateSupplying, fixing, testing and commissioning of single sink with large basin for Hospital use. Pedal-controlled faucet and button-controlled soap dispenser. The basin is supplied complete with drain, siphon, flexible connection to the water mains and plugs for wall mounting. ---- etc., complete with all lead Nos25370.025370.02.0FalseNoneNoneFalseNoneFalse50740.00
3623202131621NoneV-6,ELE 7.3.2Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector FPC of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding. 200 L Capacity Ground Floor ---- etc., complete with all lead Each57019.2857019.283.0FalseNoneNoneFalseNoneFalse171057.840
3623203131621NoneV2,13.34Providing and placing on terrace at all floor levels polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Ground Floor ---- etc., complete with all lead l10.9410.944000.0FalseNoneNoneFalseNoneFalse43760.00
3623204131621NoneV-1,1.4Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. ---- etc., complete with all lead Cum294.13294.13705.0FalseNoneNoneFalseNoneFalse207361.650
3623205131621NoneV-1,1.11Filling approved earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead Cum526.27526.27705.0FalseNoneNoneFalseNoneFalse371020.350
3623206131621NoneV-5,10.3.7Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes with cost of elastomeric sealing rings and specials excluding cost of specials with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS contractor will make his own arrangements for procuring water for testing etc. complete. for: Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete with all lead m749.9749.9600.0FalseNoneNoneFalseNoneFalse449940.00
3623207131621NoneV-5,10.3.8Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes with cost of elastomeric sealing rings and specials excluding cost of specials with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS contractor will make his own arrangements for procuring water for testing etc. complete. for: Pipes of SN8 Self Fit - 200mm dia. ---- etc., complete with all lead m1081.711081.71100.0FalseNoneNoneFalseNoneFalse108171.00
3623208131621NoneV-5,10.3.9Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes with cost of elastomeric sealing rings and specials excluding cost of specials with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS contractor will make his own arrangements for procuring water for testing etc. complete. for: Pipes of SN8 Self Fit - 250mm dia. ---- etc., complete with all lead m1662.671662.67100.0FalseNoneNoneFalseNoneFalse166267.00
3623209131621NoneV-5,10.2.4Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes with cost of elastomeric sealing rings and specials excluding cost of specials with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS contractor will make his own arrangements for procuring water for testing etc. complete for: Pipes of SN4, 160mm dia. ---- etc., complete with all lead m700.07700.07250.0FalseNoneNoneFalseNoneFalse175017.50
3623210131621NoneV-5,16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm inner dimensions with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., complete with all lead Each6628.796628.7950.0FalseNoneNoneFalseNoneFalse331439.50
3623211131621NoneV-5,16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm inner dimensions with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..CATCH BASIN ---- etc., complete with all lead Each6628.796628.7925.0FalseNoneNoneFalseNoneFalse165719.750
3623212131621NoneV-2,13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size inside the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: ---- etc., complete with all lead Each3136.953136.9542.0FalseNoneNoneFalseNoneFalse131751.90
3623213131621NoneV-5,16.18.6Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame Heavy duty conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps as per IS 10910 on 12 mm dia. Grade Fe-500 steel bar as per IS 1786 staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole: Constructing Pre-cast RCC Machinehole 1.2 m internal dia. ,3.0M depth & SFRC cover & frame ---- etc., complete with all lead Nos95394.3295394.328.0FalseNoneNoneFalseNoneFalse763154.560
3623214131621NoneV5,7.5.1Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of 80mm dia. ---- etc., complete with all lead Each1920.331920.338.0FalseNoneNoneFalseNoneFalse15362.640
3623215131621NoneV5,7.5.2Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of 100mm dia. ---- etc., complete with all lead Each2261.862261.866.0FalseNoneNoneFalseNoneFalse13571.160
3623216131621NoneV5,7.5.3Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of 150mm dia. ---- etc., complete with all lead Each2879.282879.282.0FalseNoneNoneFalseNoneFalse5758.560
3623217131621NoneV-2,13.33.5Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes ---- etc., complete with all lead m579.75579.75250.0FalseNoneNoneFalseNoneFalse144937.50
3623218131621NoneV-2,13.33.6Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal dia Pipes ---- etc., complete with all lead m876.3876.3250.0FalseNoneNoneFalseNoneFalse219075.00
3623219131621NoneV-5,21.1.11Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant RO+UF with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. Ref- detailed specification enclosed seperatly. Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each componentsFor For 2000 LPH FRP : Skid Type ---- etc., complete with all lead Each748686.4748686.41.0FalseNoneNoneFalseNoneFalse748686.40
3623220131621NoneV-5,20.8.3Automatic Online Hydraulically Operated Self Cleaning Multi grade Pressure Filter for the flow rate of ........................... LPH ............... M.L.D with 16 hour pumping NOTE : For Detailed Specification of Automatic hydraulic self cleaning screen filter400 Microns, FILTRATION & Filter Media For Pressure Filter, Anthracite, Carbon . Detailed Specification and Rates fot Separate components i.e.., Online Sensore, Filtration & Filder media of 10000 LPH to 225000 LPH Refer Annexure-C For 30000 LPH 0.48 M.L.D ---- etc., complete with all lead Set1542342.61542342.61.0FalseNoneNoneFalseNoneFalse1542342.60
3623221131621NoneV5,13.40.1Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. pump room collection sump pumps 2 HP, Size 65x50 Head 13M, Discharge 462 LPM ---- etc., complete with all lead Each18972.3918972.392.0FalseNoneNoneFalseNoneFalse37944.780
3623222131621NoneV5,13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all lead Job7900.17900.12.0FalseNoneNoneFalseNoneFalse15800.20
3623223131621NoneV5,13.40.5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. Raw water pumps 5 HP, size 50x40 Head 46M, Discharge 174 LPM ---- etc., complete with all lead Each32107.2232107.222.0FalseNoneNoneFalseNoneFalse64214.440
3623224131621NoneV5,13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all lead Job7900.17900.12.0FalseNoneNoneFalseNoneFalse15800.20
3623225131621NoneV5,13.40.3Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. DOMESTIC 3 HP, size 50x40 Head 30M, Discharge 198 LPM ---- etc., complete with all lead Each22868.9722868.972.0FalseNoneNoneFalseNoneFalse45737.940
3623226131621NoneV5,13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all lead Job7900.17900.12.0FalseNoneNoneFalseNoneFalse15800.20
3623227131621NoneV5,13.40.3Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. FLUSHING 3 HP, size 50x40 Head 30M, Discharge 198 LPM ---- etc., complete with all lead Each22868.9722868.972.0FalseNoneNoneFalseNoneFalse45737.940
3623228131621NoneV5,13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all lead Job7900.17900.12.0FalseNoneNoneFalseNoneFalse15800.20
3623229131621NoneV5,13.40.3Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. DOMESTIC 2 HP, Size 50x40 Head 22M, Discharge 186 LPMDOCTOR'S QTRS ---- etc., complete with all lead Each20653.2920653.292.0FalseNoneNoneFalseNoneFalse41306.580
3623230131621NoneV5,13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all lead Job7900.17900.12.0FalseNoneNoneFalseNoneFalse15800.20
3623231131621NoneV5,13.40.3Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. DOMESTIC 2 HP, Size 50x40 Head 22M, Discharge 186 LPMNURSE'S QTRS ---- etc., complete with all lead Each20653.2920653.292.0FalseNoneNoneFalseNoneFalse41306.580
3623232131621NoneV5,13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all lead Job7900.17900.12.0FalseNoneNoneFalseNoneFalse15800.20
3623233131621NoneV5,13.40.3Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. DOMESTIC 2 HP, Size 50x40 Head 22M, Discharge 186 LPMMORTUARY ---- etc., complete with all lead Each20653.2920653.292.0FalseNoneNoneFalseNoneFalse41306.580
3623234131621NoneV5,13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all lead Job7900.17900.12.0FalseNoneNoneFalseNoneFalse15800.20
3623235131621NoneV-6,15.83.1FIRE FIGHTING-Supplying, Installing, testing and commissioning approved make Centrifugal pump end suction type couple to Electric motor of suitable Hp, fitted on a common base frame and rated for Fire duty. The quoted price shall aslso include 2 nos. Pressure guages fitted on suction & delivery side of the pump. The pumps shall run on 400/440V, 3 ph, 50Hz electric supply. Duty of pums: 1620 Lpm at 70.0m Head.Control panel shall be per specification stated in Item No.87. including cost of materials, labour, usage charges of machinery complete as per specifications. Cost of control pannel is not included ---- etc., complete with all lead No285619.0285619.01.0FalseNoneNoneFalseNoneFalse285619.00
3623236131621NoneV-6,15.84.2Supplying, Installing testing and commissioning of fire hydrant multi stage pump capable of delivering 1620 Lpmat 70.0m head coupled to water coiled diesel enginer of adequate. HP It shall be fitted with a radiator on a common base frame with complete ancillary units such as coiling sytem, non return vialve, Y strainer, fuel tank of adequante capactiy, Pressure guage, pressure switch etc. complete Control panel shall be per specification stated in Item No.87. including cost of materials, labour, usage charges of machinery complete as per specifications. Cost of control pannel is not included ---- etc., complete with all lead No595546.0595546.01.0FalseNoneNoneFalseNoneFalse595546.00
3623237131621NoneV-6,15.85Supplying, Installing testing & commissioning electrically driven jockey pump of capacity 180.0 Lmpm at 75.0m head with all the necessary accessories viz. Pressure guages etc. operating on 3Ph 50Hz, 400/440V AC supply including foundation bolt etc. complete. Control panel shall be as per item No.87, including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead No103309.0103309.01.0FalseNoneNoneFalseNoneFalse103309.00
3623238131621NoneV-6,15.139Supplying Installing testing and commissiong COMMON Control panel for fire fighting system consiting of electrical motor driven 60HP Main fire pump, Diesel engine driven pump 60 HP Sprinkler pump 50HP & Jockey pump 25HP ---- etc., complete with all lead Unit337881.2337881.21.0FalseNoneNoneFalseNoneFalse337881.20
3623239131621NoneV-6,15.127.1Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 200mm dia ---- etc., complete with all lead Nos19446.419446.42.0FalseNoneNoneFalseNoneFalse38892.80
3623240131621NoneV-6,15.127.2Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 150mm dia ---- etc., complete with all lead Nos15192.515192.53.0FalseNoneNoneFalseNoneFalse45577.50
3623241131621NoneV-6,15.127.3Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 100mm dia ---- etc., complete with all lead Nos10938.610938.69.0FalseNoneNoneFalseNoneFalse98447.40
3623242131621NoneV-6,15.127.4Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 80mm dia ---- etc., complete with all lead Nos8507.88507.81.0FalseNoneNoneFalseNoneFalse8507.80
3623243131621NoneV-6,15.128.2Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150 mm dia ---- etc., complete with all lead Nos13977.113977.12.0FalseNoneNoneFalseNoneFalse27954.20
3623244131621NoneV-6,15.128.3Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia ---- etc., complete with all lead Nos8653.658653.652.0FalseNoneNoneFalseNoneFalse17307.30
3623245131621NoneV-6,15.128.4Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80 mm dia ---- etc., complete with all lead Nos6684.76684.71.0FalseNoneNoneFalseNoneFalse6684.70
3623246131621NoneV-6,15.129.1Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.200mm dia ---- etc., complete with all lead No29777.329777.31.0FalseNoneNoneFalseNoneFalse29777.30
3623247131621NoneV-6,15.129.2Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia ---- etc., complete with all lead No22545.6722545.672.0FalseNoneNoneFalseNoneFalse45091.340
3623248131621NoneV-6,15.136Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. ---- etc., complete with all lead No36462.036462.01.0FalseNoneNoneFalseNoneFalse36462.00
3623249131621NoneV-6,15.132Pressure guage of 150 mm dia including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec. ---- etc., complete with all lead No3524.663524.663.0FalseNoneNoneFalseNoneFalse10573.980
3623250131621NoneV-6,15.131Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. ---- etc., complete with all lead Nos2370.032370.033.0FalseNoneNoneFalseNoneFalse7110.090
3623251131621NoneVOL-2,11.16.2Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc. trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead Kg178.66178.66450.0FalseNoneNoneFalseNoneFalse80397.00
3623252131621NoneBSR 21-22,32.14FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed.3.5 Core 95.00 Sq.mm.Main Panel Electrical Pump ---- etc., complete with all lead Mtr624764.22624764.220.12FalseNoneNoneFalseNoneFalse74971.70640
3623253131621NoneBSR 21-22,32.05FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed.4.0 Core 16.00 Sq.mm.Main Panel to Jockey ---- etc., complete with all lead Mtr222955.41222955.410.5FalseNoneNoneFalseNoneFalse111477.7050
3623254131621NoneQuotation RateFIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed.12 Core x 2.5Sqmm For Main Panel to DG ---- etc., complete with all lead Mtr684.4684.450.0FalseNoneNoneFalseNoneFalse34220.00
3623255131621NoneV-6,2.5.2Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and Virgin PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990, 3C x 1.5 mm for Pressure switch ---- etc., complete with all lead Mtr87.5187.51110.0FalseNoneNoneFalseNoneFalse9626.10
3623256131621NoneV-6,9.4.6Supplying, installation, testing & commissioning of 12V ..AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type. 150 AH capacity ---- etc., complete with all lead Nos34258.4834258.481.0FalseNoneNoneFalseNoneFalse34258.480
3623257131621NoneQuotation RateSupply, installing, diesel tank for diesel engine 200lit cap ---- etc., complete with all lead Nos33630.033630.01.0FalseNoneNoneFalseNoneFalse33630.00
3623258131621NoneCPWD SR 21-22,4.1.4Supplying and installing following size of perforated painted with powder cating m.s. cable trays with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspendrrs etc as required. ---- etc., complete with all lead Mtr944.37944.37100.0FalseNoneNoneFalseNoneFalse94437.00
3623259131621NoneV-6,12.58.2GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 3 mm GI strip ---- etc., complete with all lead Mtr99.6699.66200.0FalseNoneNoneFalseNoneFalse19932.00
3623260131621NoneV-6,15.86Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all lead Each1823.11823.11.0FalseNoneNoneFalseNoneFalse1823.10
3623261131621NoneV-6,15.125SITC of Gun metal BALL VALVE SIZE OF 25mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all lead Nos1458.481458.485.0FalseNoneNoneFalseNoneFalse7292.40
3623262131621NoneV-6,15.97.2Supply, Installation testing and commissioning of approved make heavy quantity Class 'C' confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.200 mm dia ---- etc., complete with all lead m5226.225226.2230.0FalseNoneNoneFalseNoneFalse156786.60
3623263131621NoneV-6,15.97.3Supply, Installation testing and commissioning of approved make heavy quantity Class 'C' confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.150 mm dia ---- etc., complete with all lead m4740.064740.0615.0FalseNoneNoneFalseNoneFalse71100.90
3623264131621NoneV-6,15.97.4Supply, Installation testing and commissioning of approved make heavy quantity Class 'C' confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.100 mm dia ---- etc., complete with all lead m3463.893463.8915.0FalseNoneNoneFalseNoneFalse51958.350
3623265131621NoneV-6,15.97.5Supply, Installation testing and commissioning of approved make heavy quantity Class 'C' confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 80 mm dia ---- etc., complete with all lead m2795.422795.426.0FalseNoneNoneFalseNoneFalse16772.520
3623266131621NoneV-6,15.97.10Supply, Installation testing and commissioning of approved make heavy quantity Class 'C' confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.25 mm dia ---- etc., complete with all lead m850.78850.7824.0FalseNoneNoneFalseNoneFalse20418.720
3623267131621NoneQuotation RateSupply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the worSocket Elbow 25/15 ---- etc., complete with all lead Nos212.4212.4400.0FalseNoneNoneFalseNoneFalse84960.00
3623268131621NoneQuotation RateSupply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the worSocket Elbow 25/25 ---- etc., complete with all lead Nos212.4212.430.0FalseNoneNoneFalseNoneFalse6372.00
3623269131621NoneQuotation RateSupply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the wor Socket Tee 25/15/25 ---- etc., complete with all lead Nos295.0295.040.0FalseNoneNoneFalseNoneFalse11800.00
3623270131621NoneQuotation RateSupply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the wor Socket Tee 25/25/25 ---- etc., complete with all lead Nos295.0295.020.0FalseNoneNoneFalseNoneFalse5900.00
3623271131621NoneQuotation RateSupply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the wor Socket Tee 32/15/32 ---- etc., complete with all lead Nos413.0413.030.0FalseNoneNoneFalseNoneFalse12390.00
3623272131621NoneQuotation RateSupply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the wor Socket Tee 32/25/32 ---- etc., complete with all lead Nos365.8365.810.0FalseNoneNoneFalseNoneFalse3658.00
3623273131621NoneQuotation RateSupply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the wor Socket Tee 40/15/40 ---- etc., complete with all lead Nos531.0531.060.0FalseNoneNoneFalseNoneFalse31860.00
3623274131621NoneQuotation RateSupply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the wor Socket Tee 40/25/40 ---- etc., complete with all lead Nos531.0531.060.0FalseNoneNoneFalseNoneFalse31860.00
3623275131621NoneQuotation RateSupply, Erection, Testing & commissioning of MS Forged Tees & Collar ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the worForged Collar 25/15 ---- etc., complete with all lead Nos129.8129.8800.0FalseNoneNoneFalseNoneFalse103840.00
3623276131621NoneV-6,15.97.3Supply, Installation testing and commissioning of approved make heavy quantity Class 'C' confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 150 mm dia ---- etc., complete with all lead m4740.064740.06500.0FalseNoneNoneFalseNoneFalse2370030.00
3623277131621NoneV-6,15.97.4Supply, Installation testing and commissioning of approved make heavy quantity Class 'C' confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 100 mm dia ---- etc., complete with all lead m3463.893463.89300.0FalseNoneNoneFalseNoneFalse1039167.00
3623278131621NoneV-6,15.97.5Supply, Installation testing and commissioning of approved make heavy quantity Class 'C' confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 80 mm dia ---- etc., complete with all lead m2795.422795.42400.0FalseNoneNoneFalseNoneFalse1118168.00
3623279131621NoneV-6,15.97.6Supply, Installation testing and commissioning of approved make heavy quantity Class 'C' confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 65 mm dia ---- etc., complete with all lead m2066.182066.18200.0FalseNoneNoneFalseNoneFalse413236.00
3623280131621NoneV-6,15.97.7Supply, Installation testing and commissioning of approved make heavy quantity Class 'C' confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 50 mm dia ---- etc., complete with all lead m1580.021580.02275.0FalseNoneNoneFalseNoneFalse434505.50
3623281131621NoneV-6,15.97.8Supply, Installation testing and commissioning of approved make heavy quantity Class 'C' confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 40 mm dia ---- etc., complete with all lead m1276.171276.17185.0FalseNoneNoneFalseNoneFalse236091.450
3623282131621NoneV-6,15.97.9Supply, Installation testing and commissioning of approved make heavy quantity Class 'C' confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 32 mm dia ---- etc., complete with all lead m972.32972.32120.0FalseNoneNoneFalseNoneFalse116678.40
3623283131621NoneV-6,15.97.10Supply, Installation testing and commissioning of approved make heavy quantity Class 'C' confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 25 mm dia ---- etc., complete with all lead m850.78850.78300.0FalseNoneNoneFalseNoneFalse255234.00
3623284131621NoneV-6,15.98.2Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint Black and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 150 mm dia ---- etc., complete with all lead m486.16486.16500.0FalseNoneNoneFalseNoneFalse243080.00
3623285131621NoneV-6,15.98.3Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint Black and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 100 mm dia ---- etc., complete with all lead m303.85303.85150.0FalseNoneNoneFalseNoneFalse45577.50
3623286131621NoneV-6,15.127.6Supplying, installing , testing and commissioning approved make CI butterfly valves of 50mm diameter confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all lead Nos5469.35469.36.0FalseNoneNoneFalseNoneFalse32815.80
3623287131621NoneCPWD -21-22,18.23.2Providing & fixing Flow Switch in following sizes M.S. pipe including connnection etc as required.150mm dia ---- etc., complete with all lead Each10964.1210964.126.0FalseNoneNoneFalseNoneFalse65784.720
3623288131621NoneV-6,15.96.2Providing, fixing, testing & commissioning ofinstallation control valve of cast iron body,brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm andhydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia ---- etc., complete with all lead Each85078.085078.01.0FalseNoneNoneFalseNoneFalse85078.00
3623289131621NoneV-6,15.123Supplying Installing, testing and commissioning of 150mm dia 4 way Fire brigade inlet connection with Non retrn valve of 4 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead No46185.246185.21.0FalseNoneNoneFalseNoneFalse46185.20
3623290131621NoneV-6,15.124Supplying Installing, testing and commissioning of 100mm dia 2 way Fire brigade inlet connection of 2 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead No40108.240108.21.0FalseNoneNoneFalseNoneFalse40108.20
3623291131621NoneV-6,15.86FIRE HYDRANT SYSTEM Supplying Installing, testing and commissioning of 63mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve,spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead No12761.712761.715.0FalseNoneNoneFalseNoneFalse191425.50
3623292131621NoneV-6,15.88Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos .RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead Each6077.06077.030.0FalseNoneNoneFalseNoneFalse182310.00
3623293131621NoneV-6,15.87Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour,usage charges of machinery complete as per specifications. ---- etc., complete with all lead Each5469.35469.315.0FalseNoneNoneFalseNoneFalse82039.50
3623294131621NoneV-6,15.89Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size 20"x24"x10" complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead Each7900.17900.19.0FalseNoneNoneFalseNoneFalse71100.90
3623295131621NoneV-6,15.9Supplying Installing, testing and commissioning of Hose reel cabin ---- etc., complete with all lead Each6198.546198.546.0FalseNoneNoneFalseNoneFalse37191.240
3623296131621NoneV-6,15.91Supplying Installing, of M.S. Pressed reel of 600mm dia swinging type motion which allows a 180 swing and conforms to IS:884/85 or Aluminium fitting Single Piece Compact Type. including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead Each6320.086320.086.0FalseNoneNoneFalseNoneFalse37920.480
3623297131621NoneV-6,15.92Supplying Installing, testing and commissioning of 19mm dia 40.0m length hose with rubber lining smooth bore, reinforced of natural/synthetic fibres, a rubber cover finish shall be smooth, fluted or fabric marked with minimum thickness of 1.50mm and to with stand a working pressure of 10Kgf/sqcm confirms & tested as per IS 444/ IS 12585 including cost of materials, labour, usage charges of machinery complete as per specifications ---- etc., complete with all lead Each6320.086320.0815.0FalseNoneNoneFalseNoneFalse94801.20
3623298131621NoneV-6,15.86Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all lead Each1823.11823.13.0FalseNoneNoneFalseNoneFalse5469.30
3623299131621NoneV-6,15.125SITC of Gun metal BALL VALVE SIZE OF 25mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all lead Nos1458.481458.486.0FalseNoneNoneFalseNoneFalse8750.880
3623300131621NoneV-6,13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete so as to make it leak proof. ---- etc., complete with all lead Nos380.42380.4218.0FalseNoneNoneFalseNoneFalse6847.560
3623301131621NoneV-6,15.93Supplying Installing, testing and commissioning of approved make 15mm dia sprinkler bulb pendent/wall mounted type designed to operate 68 degrees centegrad Make Tyco/HD FIRE complete Colour code of bulb liquid inside Glass bulb type Pendents As per IS 9972: 57 COrange, 68 C - Red, 79 C - Yellow, 93 C - Green, 141 C - Blue, 182 C Mauve, 227/260 C - Black ---- etc., complete with all lead Each455.78455.78800.0FalseNoneNoneFalseNoneFalse364624.00
3623302131621NoneQuotation RateSupply, Erection, Testing & commissioning of MS Forged Collar 1" ---- etc., complete as per specificaiton with all lead and lift and as per directions of the Engineer-in-charge of the work ---- etc., complete with all lead Nos259.6259.6800.0FalseNoneNoneFalseNoneFalse207680.00
3623303131621NonePWD SR VOL-2,11.16.2Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc. trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead Kg178.66178.662000.0FalseNoneNoneFalseNoneFalse357320.00
3623304131621NoneV-6,15.33CO2 2Kg Squeeze grip Providing 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all lead Each6684.76684.76.0FalseNoneNoneFalseNoneFalse40108.20
3623305131621NoneV-6,15.4Providing Aqueous Film-Forming Foam - 9 Ltr Providing 9 Ltr Fire Extinugisher Aqueous Film-Forming Foam Type, Stored Pressure Type, Pressure Gauge, Gross Weight 15.1Okg. empty weight 6.10kg Can Height 615 MM, Diameter 175 MM, Discharge Time less than 60 Sees, Controllable discharge mechanism Squeeze grip with easy snap safety seal, Range minimum 6 Meters, applicable on Class A,8,CARating 13A, 8 Rating 558, Can Construction;Deep drawn & CO, Mig welded, Valve Construction: Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy PoIyster Powder coating, Sheet metal thickness: 2.0MM, lSI and EN Approved, Helium Leak Detection Tested, 1 Years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all lead Each9844.749844.742.0FalseNoneNoneFalseNoneFalse19689.480
3623306131621NoneV-6,15.4Providing ABC Powder based MAP 50, 6Kg:-Providing 6kg Fire Extinguisher Mono Ammonium Phos phate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees, Controllable discharge mechanism Squeeze grip with easy snap safety seal, Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire, A Rating 3A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete. IS 15683 Approved, ---- etc., complete with all lead Each3463.893463.892.0FalseNoneNoneFalseNoneFalse6927.780
3623307131621NoneV-6,15.34Supply, installation in position, testing and commissioning of 4.5Kg C0 Gas Type Fire Extinugisher, Trolley Mounted, 2 Easy Weight Management used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuctin : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved 1Year Warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all lead Each7900.17900.14.0FalseNoneNoneFalseNoneFalse31600.40
3623308131621NonePWD SR -21-22,15.72Providing and fixing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners. Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source in minutes 60 minutes, Luminescent intensity milicandelas * per square meter - mcd/sqm : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* In Minutes :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.Signage with the following text "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" Size:-25cm x 30 cm ---- etc., complete with all lead Sq CM2.432.4311640.0FalseNoneNoneFalseNoneFalse28285.20
3623309131621NoneV-6,15.106Providing and fixing in position the signages FIRE ORDER it should contain the following text on 3mm thick Opaque PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of size 3' x 4'.A ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS.B EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POITS.C IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER.D BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC, WALK, DO NOT RUN.D GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE.E IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER: Current phone numbers to be provided in this location by the contractorF FIRE FIGHTING AGENCY: PHONE : Current phone numbers to be provided in this location by the contractorFAX : Current fax numbers to be provided in this location by the contractor ---- etc., complete with all lead Each3038.53038.54.0FalseNoneNoneFalseNoneFalse12154.00
3623310131621NoneV-6,15.108.2Supplying Installing, testing and commissioning of P.A.System console panel with push button with speaker and indictoron Accomdated in M.S.Cabinet with painting -do- 20 Zone cansole. Complete ---- etc., complete with all lead Nos51046.851046.81.0FalseNoneNoneFalseNoneFalse51046.80
3623311131621NoneV-6,15.109P.A.System amplifier 250W RMS out put with complete wiring and controls accessable form front ---- etc., complete with all lead Nos42842.8542842.851.0FalseNoneNoneFalseNoneFalse42842.850
3623312131621NoneV-6,15.109Supplying Installing, testing and commissioning of MIKE ---- etc., complete with all lead Each6684.76684.71.0FalseNoneNoneFalseNoneFalse6684.70
3623313131621NoneV-6,15.107Supplying Installing, testing and commissioning of Public address system Two way comminication type as per requirement of Fire Force authority and which Generally comprise of Supplying Installing, testing and commissioning of Approved make 5W.wall mounted speaker with talk back facility with store enamel painted M.S.Sheet hosing etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead Each2977.732977.734.0FalseNoneNoneFalseNoneFalse11910.920
3623314131621NoneV-6,15.105Supply & Laying of 2 X 1.5 Sqmm fire alarm armored cable,600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. ---- etc., complete with all lead Mtr182.31182.312365.0FalseNoneNoneFalseNoneFalse431163.150
3623315131621NoneV-6,15.66.1Supply, install, test and commissioning of addressable peer to peer Networkable analogue addressable type fire alarm control panel with minimum 1500 Character /240X64 Pixel / 7inch Touchscreen graphic LCD display. The panel should be equipped with sufficient numbers of loop with 20% spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 126/240 detectors/ devices in any combination with key pad, dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NAC's, min 20 programmable Zonal LEDs and operates on 240V AC + 10% with 50Hz with built in charger. The panel shall have fire, fault relays, option of BMS integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, Class 'X' wiring with provision of both class 'A' and class 'B' wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels/ Nodes in one network with all other accessories required to successfully run the system. The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design. Approval: VDS/UL/EN-54 Std.2 Loop Panel ---- etc., complete with all lead Each255234.0255234.01.0FalseNoneNoneFalseNoneFalse255234.00
3623316131621NoneCPWD,17.2.2Supply, intallation, testing and Commissioning of Graphical software for entire fire alarm panels including detector configuration, commissioning etc ---- etc., complete with all lead Each243822.61243822.611.0FalseNoneNoneFalseNoneFalse243822.610
3623317131621NoneV-6,15.103Supplying Installing, testing and commissioning of Response Indicator constists of twin LED wioth electronic circutarx work on 24 DC enclose in PVC retangular. complete including cost of materials, labour, HOM complete as per specifications. ---- etc., complete with all lead Each303.85303.8550.0FalseNoneNoneFalseNoneFalse15192.50
3623318131621NoneV-6,15.67Supply, Installation , Testing & Commissioning  of Network Active Repeater Panel with 1500 Character / 240X64 Pixel / 7inch Touchscreen. The LCD shall Display all events / detectors, devices status of complete systems in the networked.  Approval: UL/VDS/EN54. Make: ---- etc., complete with all lead Each79001.079001.01.0FalseNoneNoneFalseNoneFalse79001.00
3623319131621NonePWD SR 21-22,15.66Supply, intallation, testing and Commissioning of loop card ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead Each3403.123403.122.0FalseNoneNoneFalseNoneFalse6806.240
3623320131621NoneV-6,15.1Supply Installation testing & Commissioning of conventional type photo/Heat electric smoke sensor with flashing LED capable of woking at 9V to 33 V DC .The Optical Smoke Detector is unaffected by wind or atmosphericpressure and operates over the temperature range -20 C to +60 C. IP Rating at IP 23D & Approval with EN-54 -7, LPCB Approved. ---- etc., complete with all lead Each2552.342552.34415.0FalseNoneNoneFalseNoneFalse1059221.10
3623321131621NoneLeast Quotation Rate,SITC OF Fault isolation module:- Supply, Erection,Testing and Commissioning of UL-APPROVED Analog addressable fault isolator circuit modules of wall mounted type with mounting accessories. ---- etc., complete with all lead Each7080.07080.014.0FalseNoneNoneFalseNoneFalse99120.00
3623322131621NoneV-6,15.68Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Sounder & Beacon  with inbuilt isolator and  having Min 15 distinct sound patterns/ multitone to indicate Exit doors and direct occupants for safe and fast evacuation and 100dB output with minimum 1Hz Frequency flash rate designed for IP65 requirements and approved to operate in 10 C to +55 C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device Approval: VDS/UL/EN54. Make: Advanced UK,Simplex, Notifier,ArgusUk ---- etc., complete with all lead Each5955.465955.4620.0FalseNoneNoneFalseNoneFalse119109.20
3623323131621NoneV-6,15.102Supplying Installing, testing and commissioning of electronic Hooter, it conists of electronic circuit to give dual Fire alaram sound with works. 24V DC with speaker all encased in suitable in MS 16 gauge red painted box. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead Each1823.11823.14.0FalseNoneNoneFalseNoneFalse7292.40
3623324131621NoneV-6,15.73Supplying Installing, testing and commissioning of Resettable type Manual Call point . works on 24V DC LED indicator with glass Fronted. Fire Symbol .The red Manual Call Point is approved to EN54-11 standard. MECHANICAL CONSTRUCTION The component parts of the call point are moulded in polycarbonate or ABS, depending on their function. ---- etc., complete with all lead Each3646.23646.28.0FalseNoneNoneFalseNoneFalse29169.60
3623325131621NoneELE-SR - 23-24,1.4.2Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.100 x 75 x 65 mm ---- etc., complete with all lead Each143.42143.42415.0FalseNoneNoneFalseNoneFalse59519.30
3623326131621NonePWD SR,15.72Supply, install, test and commissioning of Analogue addressable Monitor Cum Control Input/Output module 1+1 with inbuilt relay and isolator with LED indicator, approved to operate in 10 C to +55 C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. In case of Manufacturer with single Input or Output module need to supply One quantity of each for line item.For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device Approval: EN54. ---- etc., complete with all lead Each4740.064740.061.0FalseNoneNoneFalseNoneFalse4740.060
3623327131621NonePWD SR-21-22,15.113SITC of 7AM-12 V Battery for fire alarm system ---- etc., complete with all lead Each1301.691301.696.0FalseNoneNoneFalseNoneFalse7810.140
3623328131621NoneV-5,11.2.6STP-MACHINARIES--Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings excluding the cost of fittings with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. contractor will make his own arrangements for procuring water for testing For:Heavy Duty GI Pipe etc. complete. 50 mm dia Medium duty ---- etc., complete with all lead Mtr709.79709.7930.0FalseNoneNoneFalseNoneFalse21293.70
3623329131621NoneV-5,11.2.7Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings excluding the cost of fittings with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. contractor will make his own arrangements for procuring water for testing For:Heavy Duty GI Pipe etc. complete. 65mm dia Medium duty ---- etc., complete with all lead Mtr873.87873.8712.0FalseNoneNoneFalseNoneFalse10486.440
3623330131621NoneV-5,11.2.8Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings excluding the cost of fittings with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. contractor will make his own arrangements for procuring water for testing For:Heavy Duty GI Pipe etc. complete. 80 mm dia Medium duty ---- etc., complete with all lead Mtr1082.921082.926.0FalseNoneNoneFalseNoneFalse6497.520
3623331131621NoneV-5,11.3.9Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings excluding the cost of fittings with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. contractor will make his own arrangements for procuring water for testing For:Heavy Duty GI Pipe etc. complete. 100mm dia Heavy duty ---- etc., complete with all lead Mtr1716.141716.143.0FalseNoneNoneFalseNoneFalse5148.420
3623332131621NoneQuotation RateProviding, Supplying and fixing 100 mm CI flanged puddle pipe thrust line hoisting confirming IS PRED SR page no 132/152 ---- etc., complete with all lead No7798.627798.624.0FalseNoneNoneFalseNoneFalse31194.480
3623333131621NoneV-2,13.31.6Providing and fixing Chorinated Poly Venyl Chloride CPVC/UPVC pipes conforming to IS 15778, having thermal stability for not and cold water supply including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete. Internal work exposed on wall 50mm Nominal OD Pipes PWD SR 2018-19 Page No.98. It. No.13.85.6 ---- etc., complete with all lead Mtr949.23949.2352.42FalseNoneNoneFalseNoneFalse49758.63660
3623334131621NoneV-2,13.6.4.1Providing and fixing gun metal non- return valve of approved quality screwed end : 50 mm nominal bore Horizontal ---- etc., complete with all lead No1686.281686.286.0FalseNoneNoneFalseNoneFalse10117.680
3623335131621NoneV-2,13.6.6.1Providing and fixing gun metal non- return valve of approved quality screwed end : 80 mm nominal bore Horizontal ---- etc., complete with all lead No4421.994421.994.0FalseNoneNoneFalseNoneFalse17687.960
3623336131621NoneQuotation RateKSRB-13-7.1-1 : Providing and fixing in position 100mm nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. KSRB-13-7.1-7 : do 100mm nominal bore KSRB-13-7.1-7 : do 100mm nominal bore PWD SR 2018-19 Page No.95. It. No.13.58 ---- etc., complete with all lead No3706.973706.972.0FalseNoneNoneFalseNoneFalse7413.940
3623337131621NoneQuotation RateBar Screen of size 1000 x 50mm & Bar of SS frame with 10 mm spacing ---- etc., complete with all lead No29500.029500.02.0FalseNoneNoneFalseNoneFalse59000.00
3623338131621NoneQuotation RateTwin lobe roots blower of capacity 100 cum/hr at 0.50 Kg/Cm2 with motors ---- etc., complete with all lead No182900.0182900.02.0FalseNoneNoneFalseNoneFalse365800.00
3623339131621NoneQuotation RateSS Laterals & EPDM Diffusers for SBR Bio Reactor ---- etc., complete with all lead No200600.0200600.01.0FalseNoneNoneFalseNoneFalse200600.00
3623340131621NoneQuotation RateCoarse Diffusers of Disc type, , size 50MM, ---- etc., complete with all lead No6490.06490.06.0FalseNoneNoneFalseNoneFalse38940.00
3623341131621NoneQuotation RatePressurised Sand filter of MS construction with 50 NB frontal piping and valves with air safety valve, size 1000 dia x 1250 HOS ---- etc., complete with all lead No177000.0177000.01.0FalseNoneNoneFalseNoneFalse177000.00
3623342131621NoneQuotation RateActivated Carbon Filter of MS construction with 50 NB frontal piping and valves with air safety valve, size 1000 dia x 1250 HOS ---- etc., complete with all lead No147500.0147500.01.0FalseNoneNoneFalseNoneFalse147500.00
3623343131621NoneQuotation RateRaw Effluent Pumps of size 2 HP, 3 Phase, to lift particle size of 25mm. Effluent transfer pumps one working & one standby for STP, ---- etc., complete with all lead No64900.064900.02.0FalseNoneNoneFalseNoneFalse129800.00
3623344131621NoneQuotation RateSludge Recirculation Pumps 2Nos. - 1 working &1 standby :- ---- etc., complete with all lead No41300.041300.02.0FalseNoneNoneFalseNoneFalse82600.00
3623345131621NoneQuotation RateFilter feed pumps of size3.0 HP. 3PH, to lift particle size of 25mmone working & one standby ---- etc., complete with all lead No35400.035400.02.0FalseNoneNoneFalseNoneFalse70800.00
3623346131621NoneQuotation RateChlorinator, online chlorine dosing system ---- etc., complete with all lead No29500.029500.01.0FalseNoneNoneFalseNoneFalse29500.00
3623347131621NoneQuotation RateSupply and laying of foot valve 50 nb ---- etc., complete with all lead No3687.53687.52.0FalseNoneNoneFalseNoneFalse7375.00
3623348131621NoneQuotation RateSupply and laying of Butterfly valves of 50NB, in delivery lines of delivery lines ---- etc., complete with all lead No2891.02891.015.0FalseNoneNoneFalseNoneFalse43365.00
3623349131621NoneQuotation RateSupply and fixing of non compart mentalized motor control panel with PLC & HMI , Ultrasonic level sensors ---- etc., complete with all lead No177000.0177000.01.0FalseNoneNoneFalseNoneFalse177000.00
3623350131621NoneQuotation RateSupply and laying of Electric copper cables of suitable capacity 4 core, 2.5 Sqmm with specials for all pumps ---- etc., complete with all lead No885.0885.085.0FalseNoneNoneFalseNoneFalse75225.00
3623351131621NoneQuotation RateDecanting mechanism- Electricaly actuated motorised valve of 100 mm Dia ---- etc., complete with all lead No112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3623352131621NoneQuotation RateInstrumentation & Automation - Flow meters, pr gauges, level switches ---- etc., complete with all lead No100300.0100300.01.0FalseNoneNoneFalseNoneFalse100300.00
3623353131621NoneQuotation RateMiscellaneous Consulting charges for design, drawing, preparing estimate, priliminary visit ---- etc., complete with all lead Lot29500.029500.01.0FalseNoneNoneFalseNoneFalse29500.00
3623354131621NoneQuotation RateETP - Effluent Pumps of size 1 HP, 3 Phase, to lift particle size of 25mm. Effluent transfer pumps one working & one standby for ETP, ---- etc., complete with all lead No41300.041300.02.0FalseNoneNoneFalseNoneFalse82600.00
3623355131621NoneQuotation RateAgitator - Slow speed agitator/ Submerged Aerator for mixing ETP effluent ---- etc., complete with all lead No112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3623356131621NoneQuotation RateFlocculator - Flocculator for mixing coagulants ---- etc., complete with all lead No96760.096760.01.0FalseNoneNoneFalseNoneFalse96760.00
3623357131621NoneQuotation RateChemical Dosing system - Dosing pumps, tank, strieres for mixing chemicals ---- etc., complete with all lead No94400.094400.02.0FalseNoneNoneFalseNoneFalse188800.00
3623358131621NoneQuotation RateETP modular plant - MS Epoxy coated pre fabricated ETP plant ---- etc., complete with all lead No365800.0365800.01.0FalseNoneNoneFalseNoneFalse365800.00
3623359131621NoneQuotation RateElectrical Panel - Non compartmentalised MCC panel with all control ---- etc., complete with all lead No123900.0123900.01.0FalseNoneNoneFalseNoneFalse123900.00
3623360131621NoneQuotation RatePiping - Plant Piping, valves NRV complete ---- etc., complete with all lead No41300.041300.01.0FalseNoneNoneFalseNoneFalse41300.00
3623361131621NoneQuotation RateSS Bar screen - SS bar sreen to fitt in to Screening Chamber ---- etc., complete with all lead No9440.09440.01.0FalseNoneNoneFalseNoneFalse9440.00
3623362131621NoneV-5,12.4BOREWELL-Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indic ting the location of the site, recommended depth of casing pipe required seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casin pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging techn al personal and labour required etc. NOTE: 1 Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M for fixing Casing pipes only a Above M and upto 30 M - 15%, b Above 30 M - 30% Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level. 2 A sum of R . 100/- is to be deducted for Dry Borewell towards yield test. tc. complete. ---- etc., complete with all lead Each6427.046427.041.0FalseNoneNoneFalseNoneFalse6427.040
3623363131621NoneV-5,40909Borewell depth of 0 to 50 Mtrs-Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes, collars, cap etc., complete Above 450m of drilling add 10% for every 50m depth ---- etc., complete with all lead Rmtr449.7449.750.0FalseNoneNoneFalseNoneFalse22485.00
3623364131621NoneV-5,40910Borewell depth of 50 to 100 Mtrs-Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes, collars, cap etc., complete Above 450m of drilling add 10% for every 50m depth ---- etc., complete with all lead Rmtr563.95563.9550.0FalseNoneNoneFalseNoneFalse28197.50
3623365131621NoneV-5,40911Borewell depth of 100 to 150 Mtrs-Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes, collars, cap etc., complete Above 450m of drilling add 10% for every 50m depth ---- etc., complete with all lead Rmtr599.19599.1950.0FalseNoneNoneFalseNoneFalse29959.50
3623366131621NoneV-5,40912Borewell depth of 150 to 200 Mtrs-Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes, collars, cap etc., complete Above 450m of drilling add 10% for every 50m depth ---- etc., complete with all lead Rmtr695.21695.2150.0FalseNoneNoneFalseNoneFalse34760.50
3623367131621NoneV-5,40913Borewell depth of 200 to 250 Mtrs-Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes, collars, cap etc., complete Above 450m of drilling add 10% for every 50m depth ---- etc., complete with all lead Rmtr815.53815.5350.0FalseNoneNoneFalseNoneFalse40776.50
3623368131621NoneV-5,40914Borewell depth of 250 to 300 Mtrs-Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes, collars, cap etc., complete Above 450m of drilling add 10% for every 50m depth ---- etc., complete with all lead Rmtr899.4899.450.0FalseNoneNoneFalseNoneFalse44970.00
3623369131621NoneV-5,40915Borewell depth of 300 to 350 Mtrs-Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes, collars, cap etc., complete Above 450m of drilling add 10% for every 50m depth ---- etc., complete with all lead Rmtr1054.971054.9750.0FalseNoneNoneFalseNoneFalse52748.50
3623370131621NoneV-5,12.32Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 nd latest ammendments, electrical resistance welded steel tubes, terial and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixe with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete with all lead m2349.372349.3735.0FalseNoneNoneFalseNoneFalse82227.950
3623371131621NoneV-5,13.28Supply and delivery at site 50mm2” dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments. ---- etc., complete with all lead Rmtr668.47668.47200.0FalseNoneNoneFalseNoneFalse133694.00
3623372131621NoneV-5,12.33Providing and fixing MS casing collars per IS 1239 part-II 1982 with all latest amendments if any for any dia. The thic ness of plate used for covering one end shall be 3mm minimum. The dimensions of caps and colars shall be strictly as per IS 1239 Part-II 1982 with all amendments. ---- etc., complete with all lead Nos182.31182.311.0FalseNoneNoneFalseNoneFalse182.310
3623373131621NoneV-5,12.34Providing and laying at site of wor MS asing caps as per IS 1239 part- II 1982 with all latest amendm nts if any for any dia. The thickness of plate used for covering one e shall be 3mm minimum. The dimensions of caps and olars shall be strictly as per IS 1239 Part-II 1982 with all mendments including cost of material and labour charges for fixing, if a y etc. complete with all lead and lifts and as directed by the Engineer in charge. ---- etc., complete with all lead Nos199.33199.331.0FalseNoneNoneFalseNoneFalse199.330
3623374131621None95,13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions Rates includes cost of materials fixtures and conveyance to work spot etc complete ---- etc., complete with all lead Nos255.23255.231.0FalseNoneNoneFalseNoneFalse255.230
3623375131621NoneV-5,13.13.6Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For HP etc Complete.5.00 HP - 90 LPM at 110 m = 15 STG Outlet Dia - 2.00" ---- etc., complete with all lead Each39059.3139059.311.0FalseNoneNoneFalseNoneFalse39059.310
3623376131621NoneV-5,13.23.2Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protectionsuitable for thepumpdescribedabove 1 no Indoor type NOTE: 1 DOL- Direct Online Starter 2 S-D- Star Delta Starter etc. complete.3 to 6 HP pumps ---- etc., complete with all lead Each11607.0711607.071.0FalseNoneNoneFalseNoneFalse11607.070
3623377131621NoneV-5,13.29Supply and delivery at site 50mm2” dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets ---- etc., complete with all lead Set1883.871883.871.0FalseNoneNoneFalseNoneFalse1883.870
3623378131621NoneV-5,13.31Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead Job48.6248.62100.0FalseNoneNoneFalseNoneFalse4862.00
3623379131621NoneV-5,13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all lead Job7900.17900.11.0FalseNoneNoneFalseNoneFalse7900.10
3623380131621NoneV-5,13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all lead Job1640.791640.791.0FalseNoneNoneFalseNoneFalse1640.790
3623381131621NoneV-6,2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete with all lead m204.19204.19275.0FalseNoneNoneFalseNoneFalse56152.250
3623382131621NoneV-6,5.42.2Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG ---- etc., complete with all lead Sq CM0.520.5230000.0FalseNoneNoneFalseNoneFalse15600.00
3623383131621NoneV-6,5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 Weather Proof, rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete with all lead Each17647.6117647.611.0FalseNoneNoneFalseNoneFalse17647.610
3623384131621NoneV-6,5.6.6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete with all lead Each396.38396.381.0FalseNoneNoneFalseNoneFalse396.380
3623385131621NoneV-6,5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete with all lead Each504.39504.391.0FalseNoneNoneFalseNoneFalse504.390
3623386131621NoneV-6,13.18.1Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling..15A to 63A TPST ---- etc., complete with all lead Each337.88337.881.0FalseNoneNoneFalseNoneFalse337.880
3623387131621NoneV-6,5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete with all lead Kvar583.39583.391.0FalseNoneNoneFalseNoneFalse583.390
3623388131621NoneQuotation RateMODULAR OT-DESIGN,SUPPLY ERECTION TESTING & COMISSIONING OF CLEAN ROOM SYSTEM -Providing and fixing 50 mm thick prefabricated walkable stainless steel panels ceiling The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick. And these two sheets are held together with aluminum ‘w’ section of 48mm x 10.2mm for frame work & inner space between two sheets is filled with Puff insulation with density of 40KG per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtrs. The stainless steel surface should be brush / MAT finish with antiglare property. The false ceiling panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum ‘H ‘ section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon sealent to ensure air tight vapor tight construction. The false ceiling shall be walkable with provision of service panel. The false ceiling should be fixed to the concrete slab by using 8mm treaded tension bars with adjustable turn buckles, fastener, nuts, bolts etc., complete to the concrete slab. Coving: Providing corner joint coving for wall to wall used to provide smooth and seamless corner coving buffed aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile. The required size cut outs for fixing of lights & also for any other services shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift and etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Note: The panel should be free from scratches & dents MODULAR OT area -8 mtr X6 mtr apprxt. Say 50.00 Sqm ---- etc., complete with all lead Sqm10354.510354.550.0FalseNoneNoneFalseNoneFalse517725.00
3623389131621NoneQuotation RateProviding and fixing 50 mm thick prefabricated stainless steel wall panels. The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick and these two sheets are held together with aluminum W section size 48mm x 10.2mm for frame work and inner space between two sheets is filled with Puff insulation with density of 40KG per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtrs. The stainless steel surface should be brush / MAT finish with antiglare property. The wall panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum H section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon to ensure air tight vapour tight construction. Coving:Providing corner joint coving used to provide smooth and seamless corner coving buffed Aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile. The covings shall be provided wall to wall, wall to ceiling, wall to floor. The required size cut outs for fixing of control panel and switch plate shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Note: The panel should be free from scratches & dents 6 mtr X 3 mtr X2 Nos. =36 Sqmtr 8 mtr X 3 mtr X2 Nos. =48 Sqmtr Say 84.00 Sqm Door area will be detected form wall panel ---- etc., complete with all lead Sqm10354.510354.584.0FalseNoneNoneFalseNoneFalse869778.00
3623390131621NoneQuotation RateSupplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,6mm thick. All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Srub Door /Dirty utility Door single leaf 1 mtr X 2.10 mtr Say 2.10 Sqmtr ---- etc., complete with all lead Sqm53843.453843.42.1FalseNoneNoneFalseNoneFalse113071.140
3623391131621NoneQuotation RateSupplying and Fixing HERMATICALLY SEALED STAINLESS STEEL SLIDING DOOR Providing, fabrication and fixing of manually operated hermetically sealed stainless steel sliding door of size1500 x 2100mm. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. The sliding Door runs on Nylon wheel within an Aluminium extrusion high quality rail complete with required accessories. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,6mm thick. All accessories including SS 304 grade handles- 02 sets, SS concealed Tower Bolt, etc., Complete are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ---- etc., complete with all lead Sqm96585.3696585.363.5FalseNoneNoneFalseNoneFalse338048.760
3623392131621NoneQuotation RateAntistatic Epoxy Flooring : Providing and laying 4mm thick anti-static, anti-fungal and anti-bacterial epoxy flooring after preparing the floor surface by removing all loose particles, dirt by using coir brush and vacuum cleaner. Applying one coat of Moisture barrier primer and then applying self-leveling 2mm thick moisture barrier layer to capture the moisture of the existing flooring. Then the anti static grid is laid with conductive granules and copper strips. Then apply one coat of epoxy based primer and allow for dry 6- 8 hours. Then apply epoxy putty and allow for dry 6 8 hours. And then apply 2 mm thick self-leveling epoxy flooring of approved make, colour and shade. The Epoxy flooring should be impact resistance, chemical resistance including abrasion and fumigation with R75mm coving wall to wall, wall to flooring etc., The cost includes cost of material, labour, transportation etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ---- etc., complete with all lead Sqm3835.03835.054.0FalseNoneNoneFalseNoneFalse207090.00
3623393131621NoneQuotation RateSupplying and Fixingof 2'x2' LED recessed luminarie with…. Watts system wattage. Housing shall be with pressure die cast aluminium alloy with corrosion proof resistant polyester powder coated. Driver operates with voltage range from 100v to 270V 50/60 Hz with short circuit, overload & mis-wring protection. Lumen maintenance of 70% at 50000 Hrs. injection moulded poly carbonate diffuser for better mechanical stability, light transmission & avoid pot hole effect. Junction temperature shall be 70 degree Celsius. Driver is on constant current driver at 0.06A with PF 0.9, line voltage at 50Hz, driver efficiency 85% & THD15%. LED Efficiency 130 Im/W & Fixture Efficiency 75lm/w with CRI 75 with injection moulded Polycarbonate lens with 8mm depth. 5 years Warranty against any manufacturing defect working under standard electrical condition.] ---- etc., complete with all lead Each9725.569725.568.0FalseNoneNoneFalseNoneFalse77804.480
3623394131621NoneQuotation RateSupplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X ray viewing screen shall be concealed with wall panel. ---- etc., complete with all lead Each33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
3623395131621NoneQuotation RateSupplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel. ---- etc., complete with all lead Each6903.06903.01.0FalseNoneNoneFalseNoneFalse6903.00
3623396131621NoneQuotation RatePlenum Laminar Flow :-Supply and installation of Stainless steel 304 grade Plenum LAMINAR FLOW- Plan air Ceiling mounted system with unidirectional airflow,Air flow velocity of 25 to 35 FPM Plenum unit, Holding structure & Top plenum are conforming to DIN 4799 / EU14 Mini pleate HEPA filter standards for the air distribution system complete with provision for 6 Nos. Size 1220mmX610mmX90mm thick HEPA Filters efficiency 99.97% down to 0.3 micron , 4000 cfm. The Plenum size is 1800 x 2400mm. The Diffuser is made out of SS 304 Grade material for laminar of filtered air. The complete unit will have factory prepared fine sealing system. It will be perfectly seamless. It will be made out of SS 304 Sheet of required thickness With perforated SS 304 sheet with etc., complete. ---- etc., complete with all lead Each312700.0312700.01.0FalseNoneNoneFalseNoneFalse312700.00
3623397131621NoneQuotation RateSupplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units. ---- etc., complete with all lead Each70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3623398131621NoneQuotation RateSupplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.Size 600mm x 600mm x 600mm with double door inter lock and consisiting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceted accessories. ---- etc., complete with all lead Each76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
3623399131621NoneQuotation RateSupplying and Fixing OT control Panel 6 Tile : Supply and installation of 6 tile OT control panel with distribution box, control panel will be mounted flush in the theatre wall, comprising of the following-1. Medical gas card-2. Laminar Air flow controls Temperature & humidity indicators, filter status, temperature & humidity control.-3. Digital elapsed timer -4. Hand free phone-5. Digital day timer clock-6. Lighting control panel ---- etc., complete with all lead Each129800.0129800.01.0FalseNoneNoneFalseNoneFalse129800.00
3623400131621NoneQuotation RateProviding & fixing SS304 grade return air grill. The cut out for return air grill size in panel is 600mmX450mm. The cost includes cost of material, labour charges for fixing etc complete. ---- etc., complete with all lead Each4130.04130.04.0FalseNoneNoneFalseNoneFalse16520.00
3623401131621NoneQuotation RateSUPPLY ERECTION TESTING & COMISSIONING of Return air riser made out of SS 304 grade with 18 SWG in the clean room area of 1000 CFM and provision for return air collar damper anf grill with all concted accessories. ---- etc., complete with all lead Each21240.021240.04.0FalseNoneNoneFalseNoneFalse84960.00
3623402131621NoneQuotation RateSupplying and Fixing Providing and making trap door of size 600 x 600mm in the ceiling panel by cutting. The required frame work shall be made by using Aluminium sections. The cost includes cost of material, labour charges for fixing etc complete. ---- etc., complete with all lead Each7375.07375.01.0FalseNoneNoneFalseNoneFalse7375.00
3623403131621NoneQuotation RateAHU's RECYCLE SYSTEM FOR OT AREA AS PER NABH NORMS -SUPPLY ERECTION TESTING & COMISSIONING Air handling units of GSS powder coated sheet metal cabinet type Double skin Recirculatory type 40-45 mm thick,Thermal break,modular construction.Air handling units shall be complete with Backward curved blower having capacity of 3500 t0 4000 cfm Minimum 25 to 35 ACPH with 125 mm capacity, 3.75kw TEFC motor,fan motor drive filter section with 10 microns pre filter,3 microns fine filters, DX coil 6 row section of copper coil with aluminium fins,Mist eleminator, inlet and outlet volume control dampers and bypass dampers with access doors and accessories including 10% Fresh air with module with console type and grill, 20 Microns Fresh air filter. 10% Bleed module with hepa filter,damper and grille, View glass, View lamp, limit switch for door & Pressure port for filter sections & provision to fix pressure port to measure the pressure drop across the filter, EFF1 Motor coil should be 5. 5 TR x 2 circute with all concted accessories. ---- etc., complete with all lead No597788.0597788.01.0FalseNoneNoneFalseNoneFalse597788.00
3623404131621NoneQuotation RateAIR COOLED CONDENSER UNIT & COPPER PIPING-SUPPLY ERECTION TESTING & COMISSIONING 5.5 TR Air cooled out door condensing units comprising of semi -hermetic / hermetic reciprocating/scrool compressors with matching air cooled condenser suitable for 3500 to 4000 CFM AHU provided with necessary controls.like Thermostart , Draier with MS painted stand ---- etc., complete with all lead No146320.0146320.02.0FalseNoneNoneFalseNoneFalse292640.00
3623405131621NoneQuotation RateGRILLE & DAMPER-SUPPLY ERECTION TESTING & COMISSIONING Collar damper made out of Al. with powder coated as per return air openinig size. ---- etc., complete with all lead Sqm10384.010384.02.0FalseNoneNoneFalseNoneFalse20768.00
3623406131621NoneQuotation RateSUPPLY ERECTION TESTING & COMISSIONING Aluminium Volume control dampers manual operated, Only for hepa module, unit mouth & branch Ducts ---- etc., complete with all lead Sqm13924.013924.02.0FalseNoneNoneFalseNoneFalse27848.00
3623407131621NoneQuotation RateSUPPLY ERECTION TESTING & COMISSIONING Fire Dampers with Fusible Links rated for 72 C for AHU mouth, with fire damper actuator with inter link with AHU controll panel in case of fire AHU motor should stop. ---- etc., complete with all lead No6254.06254.01.0FalseNoneNoneFalseNoneFalse6254.00
3623408131621NoneQuotation RateSUPPLY ERECTION TESTING & COMISSIONING Fire retardant flexible connections for AHU supply & return air mouth ---- etc., complete with all lead No5546.05546.02.0FalseNoneNoneFalseNoneFalse11092.00
3623409131621NoneQuotation RateDUCTING & INSULATION-SUPPLY ERECTION TESTING & COMISSIONING Al. ducting including the supports,selicon sealent with painted MS angle flanges.22 guage ---- etc., complete with all lead Sqm2006.02006.0160.0FalseNoneNoneFalseNoneFalse320960.00
3623410131621NoneQuotation RateSUPPLY ERECTION TESTING & COMISSIONING Supply & return air duct Insulation with factory laminated Al. foil class 'O' grade-13 mm thk for return air duct ---- etc., complete with all lead Sqm920.4920.480.0FalseNoneNoneFalseNoneFalse73632.00
3623411131621NoneQuotation RateSUPPLY ERECTION TESTING & COMISSIONING Supply & return air duct Insulation with factory laminated Al. foil class 'O' grade-19 mm thk for supply air duct ---- etc., complete with all lead Sqm1097.41097.490.0FalseNoneNoneFalseNoneFalse98766.00
3623412131621NoneQuotation RatePolishield covering with two coats paint for exposed duct ---- etc., complete with all lead Sqm1038.41038.470.0FalseNoneNoneFalseNoneFalse72688.00
3623413131621NoneQuotation RateSUPPLY & Fixing 300 dia Insulated flexible connection for grille module & return air raiser ---- etc., complete with all lead Rmtr979.4979.420.0FalseNoneNoneFalseNoneFalse19588.00
3623414131621NoneQuotation Rate25 mm PVC dia drain piping with supports for AHUs ---- etc., complete with all lead Rmtr625.4625.450.0FalseNoneNoneFalseNoneFalse31270.00
3623415131621NoneQuotation RateELECTRICAL & CONTROLLS-SUPPLY ERECTION TESTING & COMISSIONING Ele.controll panel inter lock with AHUs and 5.5 TR 2 nos condenser unit with TEMP. & RH Controller For AHU ---- etc., complete with all lead Set12272.012272.01.0FalseNoneNoneFalseNoneFalse12272.00
3623416131621NoneQuotation RateSUPPLY ERECTION TESTING & COMISSIONING 4 Kw Ele. Heater with RH controller to controll humidity of 50 to 60% ---- etc., complete with all lead Set66788.066788.01.0FalseNoneNoneFalseNoneFalse66788.00
3623417131621NoneQuotation Rate4C X 6 Sqmm -Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP ---- etc., complete with all lead m218.3218.360.0FalseNoneNoneFalseNoneFalse13098.00
3623418131621NoneQuotation Rate4C X 4 Sqmm -Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP ---- etc., complete with all lead m177.0177.060.0FalseNoneNoneFalseNoneFalse10620.00
3623419131621NoneQuotation Rate4C X 2.5 Sqmm -Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP ---- etc., complete with all lead m123.9123.930.0FalseNoneNoneFalseNoneFalse3717.00
3623420131621NoneQuotation Rate8C X 2.5 Sqmm S.R. -Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP ---- etc., complete with all lead m348.1348.130.0FalseNoneNoneFalseNoneFalse10443.00
3623421131621NoneQuotation Rate4C X 10 Sqmm -Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP ---- etc., complete with all lead m348.1348.130.0FalseNoneNoneFalseNoneFalse10443.00
3623422131621NoneQuotation Rate300 width x 50 ht perforated P. No.63 Item No.7.19.2-SUPPLY & Fixing Cable trey ---- etc., complete with all lead Rmtr645.46645.4630.0FalseNoneNoneFalseNoneFalse19363.80
3623423131621NoneQuotation RatePlate COpper Earthing strip 24 x 3 mm connected to existing earthing P.55 Item No.7.3.6 ---- etc., complete with all lead Rmtr617.14617.1450.0FalseNoneNoneFalseNoneFalse30857.00
3623424131621NoneQuotation RateSUPPLY & FIXING DP Gauge range 0 to 6 mm wg for OT room to monitoring positive pressure ---- etc., complete with all lead Nos10089.010089.01.0FalseNoneNoneFalseNoneFalse10089.00
3623425131621NoneQuotation RateDSUPPLY & FIXING DP Gauge range 0 to 50 mm wg for AHU & EAU pre & fine filter section to monitoring pressure drop in the filters ---- etc., complete with all lead Nos9735.09735.02.0FalseNoneNoneFalseNoneFalse19470.00
3623426131621NoneQuotation RateSupplying & Fixing Single Arm Rotating OT Pendant: Single ARM 320 Deg Rotating Anesthesia Pendant Complete with Electrical Outlets 8 Nos, Data Points 1 Nos and Medical Gas Outlets 7 Nos, 1 Monitor Tray, 2 Nos. Shelfs, 2 Nos I V Stand ---- etc., complete with all lead Nos194700.0194700.01.0FalseNoneNoneFalseNoneFalse194700.00
3623427131621NoneQuotation RateSupplying & Fixing Single Arm Rotating OT Pendant: Single ARM 320 Deg Rotating Anesthesia Pendant Complete with Electrical Outlets 8 Nos, Data Points 1 Nos and Medical Gas Outlets 7 Nos, 1 Monitor Tray, 2 Nos. Shelfs, 2 Nos I V Stand ---- etc., complete with all lead Nos194700.0194700.01.0FalseNoneNoneFalseNoneFalse194700.00
3623428131621NoneQuotation RateScrub Station MOT SCRUB STATION minimum size 1500 mm supply , installation and commissioning of compact surgical scrub sink shall be designed for use in OT area for pre-procedural scrub. Double sink combination shall be provided. Fabricated from heavy gauge type 304 stainless steel minimum thicknes 1.5 mm and shall be of seamless welded construction, polished to a satin finish.With a front access panel which shall be easily removable for access to the water controlled valve, waste connections, stoppers and strainers. Hands free operation shall include infra-red sensors with programmable adjustment. .Thermostatic mixing, valve control shall be located behind the access panel and it shall maintain constant water temperature.Timing shall be adjustable to meet individual application requiements.built in with timer setting from 1 to 10 micIt shall be provided with infrared sensors, thermostatic control taps with fail safe temprerature controls. All units shall have reduced anti-splash fronts.Knee/foot operated switch shall be provided additionally with all connected accessories. ---- etc., complete with all lead Nos278480.0278480.01.0FalseNoneNoneFalseNoneFalse278480.00
3623429131621NoneQuotation RateSupply , installation, testing and commissioning OT surgical Lighting system with connected accessroies MOT surgical lighting system shall provide an ideal combination of brightness, manoeuvrability and shadow resolution without sacrificing colour and accuracy through a consistent LED technology. Such lighting system shall have the following technical specifications: a Number of light heads : Two b Rotation system : 360 c Colour temperature range : 3800 K to 5000 K +/-10%-variable colour temperature. d CRI : 93 Ra. e LED's : Low temp . 3 Colours combination. f LED bulb life : 50,000 hrs. g Field size diameter : 20 to 28 cm +/-10% h Working range : 750 to 1100 mm +/-10% i Focus : Adjustable 100mm-250mm. j Illumination leve l: minimum 160,000 lux both for major dome and minor dome separately. k Controls : control panel two:one on the wall and other on dome/ digital with wireless remote. l Power supply : 220 V/ 50Hz AC. ---- etc., complete with all lead Nos413118.0413118.01.0FalseNoneNoneFalseNoneFalse413118.00
3623430131621NoneQuotation RateMGPS-OXYGEN MAIN MANIFOLD SYSTEM : 40 cylinder 20+20 Oxygen Manifold should be suitable to withstand a pressure of 140 Kg/Cm2and above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising high pressure copper pipes of size 12mm I.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested hydraulically at 3500 psig. ---- etc., complete with all lead Set224554.0224554.01.0FalseNoneNoneFalseNoneFalse224554.00
3623431131621NoneQuotation RateMicro process based Automatic High flow Upto 2200 ltrs/min Oxygen Control Panel. Fully automatic changeover panel 3 SOURCE FULLY AUTOMATIC OXYGEN CONTROL PANEL Working Pressure from the oxygen concentrator plant 4.1 kg/cm2 Future Provision. Working Pressure from fully automatic control panel 4.1 kg/cm2. Working Pressure from Emergency manifold system 4.1 kg/cm2. Changeover unit of all 3 sources should be at the pressure from oxygen concentrator plant Below 4.1kg/cm2. Changeover unit of all 3 sources should be at the pressure from main Manifold system Below 4.1kg/cm2.Changeover unit of all 3 sources should be at the pressure from Emergency manifold system Below 4.1kg/cm2. The Control panel shall be of fully integrated type with all safety features inbuilt for high pressure and high flow Upto 2200 ltrs / min Oxygen system. All the electrical circuits should be operated at 12 volts & 24 volts with provision of inbuilt power conversion equipment. The Panel shall have the necessary instruments, gauges, LED Indicators etc. complete with separate indicators far from separate 3 sources. Pressure from oxygen concentrator plant Green signal for Normal pressure & Red signal for Low pressure. Pressure for manifold system Green signal for Normal Pressure & Red signal for low pressure.Left bank Green signal for Normal Pressure & Red for Low pressure. In Right bank Green signal for Normal Pressure & Red for Low pressure. In Emergency manifold Green signal for Normal Pressure & Red for Low pressure. Main Line Green signal for Normal Pressure & Red for Low pressure. ---- etc., complete with all lead Nos217120.0217120.01.0FalseNoneNoneFalseNoneFalse217120.00
3623432131621NoneQuotation RateOXYGEN MANIFOLD SYSTEM :EMERGENY The Control pannel shall be of fully integrated type with all saftety futures inbuilt for high pressure and high flow upto 2200 ltrs / min Oxygen system. 4+4 Cylinder Oxygen Manifold Should be suitable be withstand a pressure of 140 Kg/Cm2and above, along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mmI.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick and a single state high pressure high flow regulator connected to a high pressure brass block. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested hydraulically at 3500 psig and necessary test certificates should accompany along with the supply. SEMI AUTOMATIC EMERGENCY OXYGEN MANIFOLD CONTROL PANEL Semi automatic control panels designed for various control functions required during supply of oxygen through the manifold unit. Enclosed in a metal cabinet. This semi automatic control panel is highly efficient in triggering the signal for the Reserve system to go operational in case primary and secondary system fails in emergency. This panel is normally connected in a permanent mode and change over is semi automatic. Some of the features of this pannels are as follows : Control panel shall be made of M.S.duly powder coated.  Easy maintenance. Highly reliable.  Designed for safety and continuity of flow supply at a constant pressure. Pressure gauge facility to indicate the gas pressure of each header and pipe line distribution pressure.  Capable to provide a distribution flow rate in excess of 1500LPM.Should have Incorporation of safety features in case pressure exceeds 100Psi. ---- etc., complete with all lead Set155760.0155760.01.0FalseNoneNoneFalseNoneFalse155760.00
3623433131621NoneQuotation RateNITROUS OXIDE MAIN MANIFOLD SYSTEM Supply, Installation, Testing and commissioning of 2 cylinder 1 + 1 Nitrous Oxide manifold supply with all necessary controls and safety fittings. Make of AKTIV or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.-SEMI AUTOMATIC NITROUS OXIDE MAIN MANIFOLD CONTROL PANEL Supply, Installation, Testing and commissioning of 500 lpm deliver capacity manifold control panel, control panel should have all necessary controls and safety fittings. with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Nitrous Oxide System ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead Set88500.088500.01.0FalseNoneNoneFalseNoneFalse88500.00
3623434131621NoneQuotation RateNITROUS OXIDE EMERGENCY MANIFOLD SYSTEM Supply, Installation, Testing and commissioning of 1 cylinders Nitrous Oxide manifold supply with all necessary controls and safety fittings and 0 To 10 Kg/cm2 High Presuure Regulator complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead Set47200.047200.01.0FalseNoneNoneFalseNoneFalse47200.00
3623435131621NoneQuotation RateMEDICAL AND SURGICAL AIR SYSTEM-Compressed Air System: System For Medical use.-Type : Reciprocating, Air cooled, Oil/ Grease free-Capacity of Piston Displacement : 52.7 cfm 1620 LpmCapacity of Piston Displacement : 52.7 cfm 1620 Lpm-Drive : Belt driven-No. of Air Compressors : 2 Nos. 1W + 1S by-Motor Capacity : 15 HP as required-Receiver Capacity : 2000 liters water capacity -After Reservoir shall have oil seperator and Moisture Receiver type : Automatic Vertical type with inlet, outlet & drain provisions ---- etc., complete with all lead Set1770000.01770000.01.0FalseNoneNoneFalseNoneFalse1770000.00
3623436131621NoneQuotation RateDuplex Medical Air Dryer System Breathing Air System 2 Nos of 1 set 100 CFM -Air Dryer Min Working Pressure should be 4 bar,-Rated Inlet Pressure should be 7 bar -Max Working Pressure should be 16 bar-Supply Voltage Should be 100-240 VAC, 50/60 Hz, 1 Ph-Rated Inlet temperature should be 38 deg C-Dryer capable to give should be 40 PDP-Purge Loss 15% -Air quality As per NFPA 99-Dual System-Three stage filter Dessicated drier-CO & Dew point level as per NFPA 99-Bacterial Penetration 0.00001%-Failure Indication-Purge Saving control Manual-No refrigerant used-Energy saving Dew point based dryer cycling. ---- etc., complete with all lead Set118000.0118000.01.0FalseNoneNoneFalseNoneFalse118000.00
3623437131621NoneQuotation RateDUPLEX COMPRESSED AIR BREATHING FILTERATION SYSTEM-3 STAGE-The filters Shouldhave maximum contaminant removal efficiency with minimum pressure drop. The filtration system should conform to breathing air filtration as per ISO 8573 Ch I Standard. Total 3-stages of filters Shouldbe used as mentioned below:-Stage 1: Oil aerosol contents removal up to 0.5 mg/cum. -Stage 2: Oil aerosol contents removal up to 0.01 mg/cum.-Stage 3: Oil content removal up to 0.003 mg/cum along with removal of oil vapor and hydrocarbon odor as per ISO 8573 Ch-I Standard. ---- etc., complete with all lead Set70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3623438131621NoneQuotation RateAir Cooler : Supply, Installation, Testing and Commissioning of 80 CFM Air cooler system, with 3 phase fan High RPM Fan suitable for 415 V, 3Phs 50 Hz ---- etc., complete with all lead Set70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3623439131621NoneQuotation RateVACCUM SUPPLY SYSTEM The pump installation shall be Duplex system consisting of 2 Nos 1W+1S BY identical Rotary Vane Type Pumps each of which shall be capable of independently producing designed systems flow rate. The pump shall be clearly marked with its performance, both its free air displacement and its volumetric throughput. Each pump should have capacity of minimum 4928LPM 300m3/h i.e., 176 CFM. Pump should be capable of providing a vacuum of not less than 650 mm Hg 87 kPa. The driving motor shall directly drive the pump unit and it shall be manufactured in accordance with HTM 2022/HTM 02-01 / conforms to IEC Standards. Recommendations suitable for 415 voltes, 3 phase, 50 Hz power supply.Each pump shall have a built in non-return valve and pressure switch such that inadvertent reversal of the motor Should not pressurize the Reservoir or the distribution system protection.-The control panel shall consist of three separate , The system should include vacuum storage reservoir tank, Rated for full vacuum services with the storage capacity of approx 3000Ltr 2Nos Receiver Tank as per standard recommendation. It should be equipped with an vacuum gauge and provision for manual draining by pass valve. The inside of the tank should be coated with a two-component coating to provide a hard, durable lining for rust -Compartments, two compartments shall hold the motor starters, MCBS ammeters, and hour’s run-meters, for each pump. The remaining compartment shall house the vacuum switches, status monitoring equipment, delay timer and necessary interlock, selector switch with automatic change over, etc., complete with internal wiring using copper conductors. Control Panel system should be front operable. ---- etc., complete with all lead Set1593000.01593000.01.0FalseNoneNoneFalseNoneFalse1593000.00
3623440131621NoneQuotation RateVACUUM BACTERIAL FILTERATION, Suitable Medical Vacuum filters are used for removal of bacteria & other contamination from the suction side of vacuum pumps, preventing infection of pump and the atmosphere. These elements shall be of pleated construction giving a high surface area and long operational life. The efficiency to exceed the 0.005% penetration specified in HTM2022 for infectious disease unit.- i.e. complete bacterial removal. Elements shall be fitted in an aluminum housing suitable for various capacities. These are to be internally protected against corrosion by an alocrom treatment. The inner & outer surfaces of the housing are epoxy coated. Complete assembly shall be fitted with a sterilisable drain flask with isolation valve for removal of liquid if any. Differential pressure indicators are to be provided to monitor the status of element. Basics Specifications are as given below. ---- etc., complete with all lead Set165200.0165200.01.0FalseNoneNoneFalseNoneFalse165200.00
3623441131621NoneQuotation RateCopper Pipe 54mm. ODx1.2 mm.thick.-PIPELINE DISTRIBUTION SYSTEM-Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead Mtr4854.524854.5280.0FalseNoneNoneFalseNoneFalse388361.60
3623442131621NoneQuotation RateCopper Pipe 42mm. ODx1.2 mm.thick.-PIPELINE DISTRIBUTION SYSTEM-Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead Mtr3608.443608.44150.0FalseNoneNoneFalseNoneFalse541266.00
3623443131621NoneQuotation RateCopper Pipe 35mm. ODx1.2 mm.thick.-PIPELINE DISTRIBUTION SYSTEM-Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead Mtr2570.042570.04230.0FalseNoneNoneFalseNoneFalse591109.20
3623444131621NoneQuotation RateCopper Pipe 28mm. ODx0.9 mm.thick.-PIPELINE DISTRIBUTION SYSTEM-Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead Mtr1492.71492.7360.0FalseNoneNoneFalseNoneFalse537372.00
3623445131621NoneQuotation RateCopper Pipe 22mm. ODx0.9 mm.thick.-PIPELINE DISTRIBUTION SYSTEM-Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.-PIPELINE DISTRIBUTION SYSTEM-Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead Mtr1156.41156.41220.0FalseNoneNoneFalseNoneFalse1410808.00
3623446131621NoneQuotation RateCopper Pipe 15mm. ODx0.9 mm.thick.-PIPELINE DISTRIBUTION SYSTEM-Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead Mtr949.9949.91970.0FalseNoneNoneFalseNoneFalse1871303.00
3623447131621NoneQuotation RateCopper Pipe 12mm. ODx0.7 mm.thick.-PIPELINE DISTRIBUTION SYSTEM-Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead Mtr651.36651.36820.0FalseNoneNoneFalseNoneFalse534115.20
3623448131621NoneQuotation RateOxygen Outlets - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keysGas specific probes ---- etc., complete with all lead Nos3392.53392.5205.0FalseNoneNoneFalseNoneFalse695462.50
3623449131621NoneQuotation RateVacuum Outlets - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keysGas specific probes ---- etc., complete with all lead Nos3392.53392.5154.0FalseNoneNoneFalseNoneFalse522445.00
3623450131621NoneQuotation RateCompressed Air Outlets 4 Bar - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keysGas specific probes ---- etc., complete with all lead Nos3392.53392.5155.0FalseNoneNoneFalseNoneFalse525837.50
3623451131621NoneQuotation RateCompressed Air Outlets 7 Bar- drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keysGas specific probes ---- etc., complete with all lead Nos3392.53392.56.0FalseNoneNoneFalseNoneFalse20355.00
3623452131621NoneQuotation RateNitrous Oxide Outlets - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keysGas specific probes ---- etc., complete with all lead Nos3392.53392.58.0FalseNoneNoneFalseNoneFalse27140.00
3623453131621NoneQuotation RateACCESSORIES ALONG WITH CALIBRATION CERTIFICATES.-Oxygen Flow meter with Humidifier Bottle        Flow meter should be Backpressure Compensated.       Flow meter should be accurate gas flow measurement and control within a range of 0-15 liters per minute.         It should meet strict precision and durability standards.        Flow meter body should be made of brass material        Flow tube and shroud components should be made of clear, impact resistant polycarbonate.        The humidifier bottle should be unbreakable polycarbonate material and autoclavable at 134 degrees centigrade.-The humidifier should have built in safety valve.-With Calibration Certificate’s. ---- etc., complete with all lead Nos2849.72849.7154.0FalseNoneNoneFalseNoneFalse438853.80
3623454131621NoneQuotation RateSingle piece wall mounted suction collection & regulation unit. With jar capacity of 600ml each shall be provided at each of the bed side. Jars are should be made of autoclavable materials. The units shall be clamped to the wall using suitable clamps. ---- etc., complete with all lead Nos3528.23528.2148.0FalseNoneNoneFalseNoneFalse522173.60
3623455131621NoneQuotation RateTheatre Vacuum      The unit should comprise of two reusable 2000 ml shatter resistant bottle, each made up of poly carbonate material and fully auto cleavable at 134 degree centigrade        Should have a vacuum regulator with instant ON / OFF switch a three way selector switch with an option to operate either. Left, Right or Both ---- etc., complete with all lead Nos14750.014750.03.0FalseNoneNoneFalseNoneFalse44250.00
3623456131621NoneQuotation RateIsolation Valves 54 mm -ISOLATION VALVES:-Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction ---- etc., complete with all lead Nos8826.48826.42.0FalseNoneNoneFalseNoneFalse17652.80
3623457131621NoneQuotation RateIsolation Valves 42 mm-ISOLATION VALVES:-Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction ---- etc., complete with all lead Nos8142.08142.03.0FalseNoneNoneFalseNoneFalse24426.00
3623458131621NoneQuotation RateIsolation Valves 35 mm -ISOLATION VALVES:-Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction ---- etc., complete with all lead Nos5428.05428.07.0FalseNoneNoneFalseNoneFalse37996.00
3623459131621NoneQuotation RateIsolation Valves 28 mm -ISOLATION VALVES:-Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction ---- etc., complete with all lead Nos4071.04071.05.0FalseNoneNoneFalseNoneFalse20355.00
3623460131621NoneQuotation RateIsolation Valves 22 mm -ISOLATION VALVES:-Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction ---- etc., complete with all lead Nos3392.53392.513.0FalseNoneNoneFalseNoneFalse44102.50
3623461131621NoneQuotation RateIsolation Valves 15 mm -ISOLATION VALVES:-Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction ---- etc., complete with all lead Nos2714.02714.072.0FalseNoneNoneFalseNoneFalse195408.00
3623462131621NoneQuotation RateZonal Valve box five Gas services -An Zonal area valve box should have bellow spec.- Wall mounted M.S. box with powder coated & lockable,- Front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.-The valve box door cannot be close during valve close position. ---- etc., complete with all lead Nos23364.023364.03.0FalseNoneNoneFalseNoneFalse70092.00
3623463131621NoneQuotation RateZonal Valve box three Gas services -An Zonal area valve box should have bellow spec.-  Wall mounted M.S. box with powder coated & lockable,  Front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.-The valve box door cannot be close during valve close position. ---- etc., complete with all lead Nos18319.518319.59.0FalseNoneNoneFalseNoneFalse164875.50
3623464131621NoneQuotation RateDigital Area Alarm for five Gas Systems.-Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors. ---- etc., complete with all lead Nos41300.041300.03.0FalseNoneNoneFalseNoneFalse123900.00
3623465131621NoneQuotation RateDigital Area Alarm for Three Gas Systems.-Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors. ---- etc., complete with all lead Nos34220.034220.09.0FalseNoneNoneFalseNoneFalse307980.00
3623466131621NoneQuotation RateBed Headed Panel and Railing. 1.5meter Double railing Bed headed panels should have below Specifications. Accessories 1. IV Stand extendable type with aluminium slider. 2. Monitor stand wall panel mounted. 3. Ward vaccum unit slider. 4. 3/6W LED light fixture. 5. Twpo duplex 230 V,6/16 Amp 6 nos of 6 amps sockets with control switches Electrical Sockets. Provision Medical Gas Terminal Units as follows.  2.1 Two oxygen outlet. 2.2  One Vacuum outlet. 2.3 One compressed Air outlet 4 Bar. ---- etc., complete with all lead Nos31860.031860.045.0FalseNoneNoneFalseNoneFalse1433700.00
3623467131621NoneQuotation RateAnaesthesia Single Arm Pendant: The material of the Pendent should be Single-armed rotary ceiling mounted surgical Pendent High-strength aluminum alloy. Extension arm 700mm.Loading capacity: 70-150kg.Level degrees rotation:340n.w.:158kg.Should be provision for Gas outlets Oxygen 02 nos, Vaccum 01 nos,Air 4 Bar 01 nos,Air 7 Bar 01 nos, Nitrous Oxide01 nos,Power socket 08 nos,Grounding terminal 01 nos,Platform 03 nos, IV pole 01 nos,Drawer 01 nos. ---- etc., complete with all lead Nos194700.0194700.02.0FalseNoneNoneFalseNoneFalse389400.00
3623468131621NoneQuotation RateConversion Kit for Anesthesia for Oxygen. Should have high pressure antistatic tubing which is color coded. ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead Nos1652.01652.03.0FalseNoneNoneFalseNoneFalse4956.00
3623469131621NoneQuotation RateConversion Kit for Anesthesia for Nitrous Oxide. Should have high pressure antistatic tubing which is color coded. ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead Nos1652.01652.03.0FalseNoneNoneFalseNoneFalse4956.00
3623470131621NoneQuotation RatePreparation of architectural drawings, structural design and drawings as per I.S Codes and got it proof checked from IISC/IIT/REC or any other equivalent reputed agency. Prepration of drawings and estimate for internal and external Electrical works, public health, engineering, fire fighting, roads, drains, land scaping, rain water harvesting, sewage treatement plant, hvac, mgps , Nurse calling system etc., ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead Lot4000000.04000000.01.0FalseNoneNoneFalseNoneFalse4000000.00
3623471131621NoneQuotation RateFURNITURE-Providing and fixing storage unit of 0.75m width made out of 19mm thick commercial ply vertical support finished in approved 1.5mm laminate with 12mm thick ply packing internally & Externally finish, shelves shall be formed out of 19mm ply finished with 1.5mm laminate of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.5mm thick laminate of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specification. ---- etc., complete with all lead Sqm11493.211493.2368.77FalseNoneNoneFalseNoneFalse4238347.3640
3623472131621NoneQuotation RateTable 2400 mm x 900 mm x 750 mm ht, Side Table 1100 mm x 450 mm x 750 mm ht. -Table : Providing and fixing Executive tables of different sizes with 19 mm waterproof plywood frame work laminated on all the exposed surface with 1 mm thick laminate and a key board tray is provided and all edges of the plywood is lipped with 19mm x 6mm teak/beach wood lipping and the edge of the table top is lipped with 32 mm x 19 mm teak/beach wood lipping. The item to include a side cabinet with 19 mm thick waterproof plywood framework, shelves and shutters laminated on all the exposed surface with 1mm thick laminate and inside surface is also laminate with 0.8 mm laminate. The item to include all hardware like stainless steel hinges, drawer sliders, Euro multipurpose locks, brush steel handles, magnetic catch, all hardware complete and all the teak/beach wood beading is polished. ---- etc., complete with all lead Set41654.041654.06.0FalseNoneNoneFalseNoneFalse249924.00
3623473131621NoneQuotation RateTable 2100 mm x 750 mm x 750 mm ht, Side Table 1100 mm x 450 mm x 750 mm ht.-Table : Providing and fixing Executive tables of different sizes with 19 mm waterproof plywood frame work laminated on all the exposed surface with 1 mm thick laminate and a key board tray is provided and all edges of the plywood is lipped with 19mm x 6mm teak/beach wood lipping and the edge of the table top is lipped with 32 mm x 19 mm teak/beach wood lipping. The item to include a side cabinet with 19 mm thick waterproof plywood framework, shelves and shutters laminated on all the exposed surface with 1mm thick laminate and inside surface is also laminate with 0.8 mm laminate. The item to include all hardware like stainless steel hinges, drawer sliders, Euro multipurpose locks, brush steel handles, magnetic catch, all hardware complete and all the teak/beach wood beading is polished. ---- etc., complete with all lead Set31270.031270.07.0FalseNoneNoneFalseNoneFalse218890.00
3623474131621NoneQuotation RateProviding and fixing Main table 1500x750x735mm, table top 25mm thick PLPB 1000x450x735mm, 25 MM THICK PLAIN PARTICLE BOARD PPB CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK Main and Side tables BACKINGLAMINATE BDL. FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD PPBCLAD WITH 1.0MM THICK DECORATIVE LAMINATE DL ON BOTH SIDES. EDGE SEALED WITH 2MM THICK PVC BEADING 25 MM THICK PLAIN PARTICLE BOARD PPB CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK BACKINGLAMINATE BDL. FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD PPBCLAD WITH 1.0MM THICK DECORATIVE LAMINATE DL ON BOTHSIDES. EDGE SEALED WITH 2MM THICK PVC BEADING. etc. as per approved drawing and directed by the engineer in charge. ---- etc., complete with all lead Set27730.027730.017.0FalseNoneNoneFalseNoneFalse471410.00
3623475131621NoneQuotation RateProviding and fixing of Three Seater Stainless Steel Waiting Chair complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Hassan Approved Rate ---- etc., complete with all lead Each42480.042480.030.0FalseNoneNoneFalseNoneFalse1274400.00
3623476131621NoneQuotation RateOptima Chairs with High Back with mesh and lumber support SEAT/BACK ASSEMBLY: The Cushioned seat assembly consists of seat outer material-30% Glass Fiber Filled Nylon& upholstered Seat inner material- Poly Propylene with moulded Polyurethane foam & polyester fabric. The Net Back is made up of Back outer material-Glass Fiber Filled Nylon& Back inner material- PP upholstered with polyester Mesh fabric. FULL BACK SIZE: 46.5 cm. W x 60.0 cm. H SEAT SIZE : 51.0 cm. W x 49.0 cm. D POLYURETHANE FOAM: The Polyurethane foam is moulded with density = 45 +/- 2 kg/m , ARMRESTS : The armrest is having two adjustment, Height and Depth. Height adjustment is provided in Aluminum structure of armrest which is connected to Aluminum Back spine And is operated by button. The depth adjustment is provided in pad which is fixed to armrest structure. Armrest Top is made up of PU molded over plastic inner. LUMBAR SUPPORT ASSEMBLY: The Lumbar suport assembly consists of lumbar spine material-Glass Fiber Filled Nylon which is fixed to Aluminum Back spine. The Lumbar pad material- Poly Propylene is fixed to lumbar spine through lumbar Pad support. Lumbar Support Assembly has height adjustment of 50mm. Neck-rest ASSEMBLY: The Neck-rest assembly consists of upholstered Neck-rest inner material- Poly Propylene etc., complete as per the direction of Engineer in charge of the work. ---- etc., complete with all lead No19470.019470.029.0FalseNoneNoneFalseNoneFalse564630.00
3623477131621NoneQuotation RateSTAFF CHAIRS : Supplying HIGH BACK Chair Blue mango with contact crome flex back chair with co-active synchro, gas lift, revolving, tilting, and height adjustable fully cushioned medium back chairs and two way adjustable arms. prior confirmation shall be obtain from the officer / Architect for approval. ---- etc., complete with all lead No7316.07316.053.0FalseNoneNoneFalseNoneFalse387748.00
3623478131621NoneQuotation RateProviding and fixing Centre Teapoy of size of 900 x 600mm oval shape as per principal chief architecht dwg no 120816/16 made out of good quality Burma Teak wood legs of cross section 50 x 10 mm and side bars of 50 x 60mm with 12mm thick modi guard glass top wtih edge grainding on polishing of oval shape of 900 x 600mm as per dwg. Polished with melamine finish in spray with necessary compressor Complete with all materials, labour, leads lifts etc and directed by Engineer in charge ---- etc., complete with all lead No10856.010856.04.0FalseNoneNoneFalseNoneFalse43424.00
3623479131621NoneQuotation RateProviding and fixing Key Board Tray plastic oridnary Tray is made of ABS in approved color and texture. Size: 570 W x275 D x 38 H MM. 350 mm Long x 11.8 mm Thk Single extension Stroke: 230 mmBall-slide Made of combination of 1.2/1.5 mm thk roll-formed CRCASteel sheet. Retrofit mouse tray is provided which could be fitted at right hand or lefthand as per user requirement. Mouse tray is made of ABS in approvedcolor and texture. Mouse Tray Size is 450 L x 198 D x 15 H MM. complete including cost and conveyance of all materials, labour for all items of work, as per the dirctions of the Engineer in charge of the work. ---- etc., complete with all lead No1416.01416.015.0FalseNoneNoneFalseNoneFalse21240.00
3623480131621NoneQuotation RateProviding and fixing CPU Trolly is made of 1.0 mm thick MS CRCA Sheet and Side support is madeof 0.8 mm thick MS CRCA Sheet.Lockable/Non-lockable twin wheel castors are injection molded in BlackNylon.as per the dirctions of the Engineer in charge of the work. ---- etc., complete with all lead No885.0885.015.0FalseNoneNoneFalseNoneFalse13275.00
3623481131621NoneQuotation RateDRINKING WATER COOLER : Providing and installing water cooler ss body and ss tank with specification Storage Capacity 80 Ltr, Normal cooling capacity 40Ltr, No of Faucets 2nos, Dimensions MM 665W x 480 D x 1210H, weight 47kg, Glasses Per hr 200Ltr, Refrigerant R-134a, current amps2.50, water over flow 1/2BSP, Typer of Compresser REIP. Including UV Corbon & Sediment filter of 250L PH water Purifier Fixing Seperatly duly connect. The rate to includ of water piping From OHT To Necessary drainage system for out let, angle cock system for as per specification. GROUND FLOOR ---- etc., complete with all lead No47200.047200.02.0FalseNoneNoneFalseNoneFalse94400.00
3623482131621NoneQuotation RatePROVIDING ALL SAFE OFFICE LOCKER STEEL ALMIRAH 900X1800X600. depth with 5 shelves of 14 gauge powder coated the rate including one locker ---- etc., complete with all lead No11564.011564.06.0FalseNoneNoneFalseNoneFalse69384.00
3623483131621NoneQuotation RateProviding and fixing 450mmw x 450 mmd x 685 mmht Mobile pedestal unit-WOODEN with 18mm thick PLPB with edge bonded for body, Two equal drawer and filing drawer with centralized locking system, Telescopic channels, castors, Handles and lock, etc., complete as per specifications, drawings and as directed by Engineer in charge. ---- etc., complete with all lead Nos4956.04956.026.0FalseNoneNoneFalseNoneFalse128856.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17219131710000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17219131710000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17219131710001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17219131710000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17219131710000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17219132110000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17219132210000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17219132290000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17219132370000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17219132450000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17219132560000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17219132650000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17219132750000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17219132840000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17219132930000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17219133050000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17219133160000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17219133260000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17219133410000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17219133500000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17219133590000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17219133720000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17219133820000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21 2021-22, 2022-23 & 2023-24.None
17219133930000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least one Satisfactorily completed at least one Similar work of value not less than Rs. 1605.00 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24). Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1) Earthwork Excavation / Filling/Embankment 12455.00 Cum 2) RCC and PCC 3801.00 Cum 3) Steel Reinforcement for RCC work 390.00 Tonnes 4) Cement Concrete Block Masonry/Solid Block Masonry/SSM 7782.00 Sqm 5) Flooring / Dadooing (Vitrified/Granite/Ceramic/Cement concrete/ cladding) 6795.00 Sqm, 6)Plastering 25809.00 Sqm, 7)Painting 23180.00 Sqm Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (c).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.201.00 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.78.00 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(f) The Tenderer or his identified Sub Contractor should have executed similar MGPLS works totaling to Rs.81.00 Lakhs in any one year.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(g) The Tenderer or his identified Sub Contractor should have executed similar Modular OT works totaling to Rs.29.00 Lakhs in any one year.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(h) The Tenderer or his identified Sub Contractor should have executed similar Furniture works totaling to Rs.40.00 Lakhs in any one year.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(i) The Tenderer or his identified Sub Contractor should have executed similar Fire Fighting works totaling to Rs.69.00 Lakhs in any one year.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.3(a)Each Tenderer should further demonstrate(a)Equipment capacity Each tenderer should further demonstrate(a) available by owning at least 50% of the required, specified key and critical equipment for this work and (b) the remaining 50% can be deployed on ease, hire basis for all works provided, the relevant documents (commitment agreements etc., for availability for this work are furnished. Sl.No Description of Equipment Total Quantity, Own, Hire 1) Self loading Concrete Mixer / Concrete Mixer Min 10 cft capacity 2 Nos, 1 No., 1No. 2) Tipper 4 Nos, 2 Nos, 2 Nos, 3) Hydraulic Excavator 1 No. 1 No 4) Centering & shuttering sheets 2500 Sqm, 1250 Sqm, 1250 Sqm, 6) Water tanker 2 Nos, 1 No., 1 No.7) Barbending Machine 2 Nos., 1 No., 1 No. & 8) Generator 2 Nos, 1 No 1 No.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tax Invoice/Agreements from the supplier
NoneNoneNoneNoneKPWD Class-I Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2019-20 to 2023-24 updated to 2024-25 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2024-25 price level of existing commitments and ongoing works to be completed during the next 18 months. Note The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Ongoing commitments and Bids submitted for the works certificate issued by the officer not less than the rank of Executive Engineer
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No Position Qualification and Requirement No Of Persons 1) Project Manager B.E. Civil with minimum experience of 15 years in the Construction of buildings 1(One). 2)Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years (1 One) and 3)Electrical Engineer B.E. Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years.1(One), 4) MEP Engineer B.E. Mechanical with minimum experience of 5 years in the Construction of buildings with plumbing, PHE, HVAC, Fire protections system etc., OR Diploma in Mechanical Engineering with minimum experience of 10 years in the Construction of buildings with plumbing, PHE, HVAC, Fire protections system etc.,1(One) 5) Site Engineer (QA QC) B.E. Civil with minimum experience of 5 years in the Construction of buildings with QA QC 1(One).6) Site Engineer(Safety Manager) Any Degree with minimum experience of 5 years in the Construction of similar buildings with Safety management OR Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings with QA QC. 1(One). Computer Operator Diploma in Computer Application & Office Procedures with 5 Years Experience1(One).Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates
NoneNoneNoneNoneClause ITT 3.2(a):The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs. 4278.00 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.642.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by a Scheduled/ Nationalized Bank
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate issued by Chartered AccountantTrueTechnical Bid
Company Registration CertificateFalseTechnical Bid
ESI & PF Registration certificatesTrueTechnical Bid
Work done certificatesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1721914053000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, HFWD, Arogya Soudha, 3rd Floor, 1st Cross Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone