3612219 | 131290 | None | 001 | Earth work in surface excavation for stripping, seating of bund, Road way by manual means for lowering & levelling the ground for all works other than foundation & depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting& stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work | Cum | 644.0 | 644.0 | 94.5 | False | None | None | False | None | False | 60858.0 | 0 |
3612220 | 131290 | None | 002 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & otherappurtenaces required to complete the work. In all kinds of soils Depth upto 3m. | Cum | 114.24 | 114.24 | 33.51 | False | None | None | False | None | False | 3828.1824 | 0 |
3612221 | 131290 | None | 003 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7041.44 | 7041.44 | 5.44 | False | None | None | False | None | False | 38305.4336 | 0 |
3612222 | 131290 | None | 004 | Providing and constructing laterite size stone masonry in CM 1:6 using available Laterite Stone including cost and conveyance of materials (except Laterite), curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Basement in CM 1:6. | Cum | 4062.24 | 4062.24 | 30.28 | False | None | None | False | None | False | 123004.6272 | 0 |
3612223 | 131290 | None | 005 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. 2.2.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7664.16 | 7664.16 | 4.31 | False | None | None | False | None | False | 33032.5296 | 0 |
3612224 | 131290 | None | 006 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6992.16 | 6992.16 | 0.97 | False | None | None | False | None | False | 6782.3952 | 0 |
3612225 | 131290 | None | 007 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 297.92 | 297.92 | 3.45 | False | None | None | False | None | False | 1027.824 | 0 |
3612226 | 131290 | None | 008 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 484.96 | 484.96 | 19.55 | False | None | None | False | None | False | 9480.968 | 0 |
3612227 | 131290 | None | 009 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specification. | Sqm | 1378.72 | 1378.72 | 81.86 | False | None | None | False | None | False | 112862.0192 | 0 |
3612228 | 131290 | None | 010 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationa. Buildings | Tonne | 100191.84 | 100191.84 | 0.42 | False | None | None | False | None | False | 42080.5728 | 0 |
3612229 | 131290 | None | 011 | Framework and Centering Considering for Percentage on finished rate of concrete per m3 (Page No:116 Appendix I SR-2021-22) beam Chejja 45% | Cum | 2809.35 | 2809.35 | 0.12 | False | None | None | False | None | False | 337.122 | 0 |
3612230 | 131290 | None | 012 | Framework and Centering Considering for Percentage on finished rate of concrete per m3 (Page No:116 Appendix I SR-2021-22) beam RCC Beams, Lintels 60% | Cum | 3745.8 | 3745.8 | 4.19 | False | None | None | False | None | False | 15694.902 | 0 |
3612231 | 131290 | None | 013 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour, curing complete as per specifications and as per directions of Engineer incharge. | Sqm | 312.48 | 312.48 | 116.69 | False | None | None | False | None | False | 36463.2912 | 0 |
3612232 | 131290 | None | 014 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6(1cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour,curingcomplete as per specifications and as per directions of Engineer-in-charge | Sqm | 415.52 | 415.52 | 117.98 | False | None | None | False | None | False | 49023.0496 | 0 |
3612233 | 131290 | None | 015 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification- 30 mm thick one side teak and one side commercial.
| Sqm | 3912.16 | 3912.16 | 2.52 | False | None | None | False | None | False | 9858.6432 | 0 |
3612234 | 131290 | None | 016 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (plus 0.05%) total coated thickness with zinc coating 120 g/m2 as per IS 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using selfdrilling/self tapping screws of size (5.5x55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required | Sqm | 636.16 | 636.16 | 60.0 | False | None | None | False | None | False | 38169.6 | 0 |
3612235 | 131290 | None | 017 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost ofmaterials, labour complete as per specifications and as per directions of Engineer in charge. | Sqm | 199.36 | 199.36 | 120.16 | False | None | None | False | None | False | 23955.0976 | 0 |
3612236 | 131290 | None | 018 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 174.72 | 174.72 | 116.9 | False | None | None | False | None | False | 20424.768 | 0 |
3612237 | 131290 | None | 019 | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).
| Sqm | 1386.56 | 1386.56 | 41.77 | False | None | None | False | None | False | 57916.6112 | 0 |
3612238 | 131290 | None | 020 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including costof materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge
| Kgs | 152.32 | 152.32 | 389.25 | False | None | None | False | None | False | 59290.56 | 0 |
3612239 | 131290 | None | 021 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware & Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7542.08 | 7542.08 | 4.14 | False | None | None | False | None | False | 31224.2112 | 0 |
3612240 | 131290 | None | 022 | Supplying heavy gauge PVC conduit pipe……mm dia thick confirming to IS 2509 with suitable size bends, metal/ PVC junction boxes, adhesive paste etc., and running before concreating the slab . The conduit should be tied to the reinforcement rods by using bending wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick (PWD Electrical SR 2023-24 P.No:2 I.No.1.2.2) | Mtr | 78.0 | 78.0 | 60.0 | False | None | None | False | None | False | 4680.0 | 0 |
3612241 | 131290 | None | 023 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box (PWD Electrical SR 2023-24 P.No:2 I.No.1.5.2) | Each | 56.0 | 56.0 | 15.0 | False | None | None | False | None | False | 840.0 | 0 |
3612242 | 131290 | None | 024 | Extra for Groove cutting in brick wall/cc floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing the wall upto wall surface complete. upto 50mm conduit CC floor (PWD Electrical SR 2023-24 P.No:3 I.No:1.7.2) | Mtr | 69.0 | 69.0 | 50.0 | False | None | None | False | None | False | 3450.0 | 0 |
3612243 | 131290 | None | 025 | Supplying and fixing Metal fan box with round hook. (PWD Electrical SR 2023-24 P.No:4 I.No:1.13) | No | 117.0 | 117.0 | 2.0 | False | None | None | False | None | False | 234.0 | 0 |
3612244 | 131290 | None | 026 | Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing caping using 1100V Grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2X1.5Sqmm cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose in a wood/PVC round block complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch box (PWD Electrical SR 2023-24 P.No:5 I.No:2.2.1) | Point | 269.0 | 269.0 | 2.0 | False | None | None | False | None | False | 538.0 | 0 |
3612245 | 131290 | None | 027 | Medium point above 3Mtr up to 6Mtrs from tapping point to out let via switch box (PWD Electrical SR 2023-24 P.No:5 I.No:2.2.2) | Point | 379.0 | 379.0 | 5.0 | False | None | None | False | None | False | 1895.0 | 0 |
3612246 | 131290 | None | 028 | Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box (PWD Electrical SR 2023-24 P.No:5 I.No:2.2.3) | Point | 555.0 | 555.0 | 8.0 | False | None | None | False | None | False | 4440.0 | 0 |
3612247 | 131290 | None | 029 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 (PWD Electrical SR 2023-24 P.No:5 I.No.2.3.1) 1 sqmm | Mtr | 19.0 | 19.0 | 50.0 | False | None | None | False | None | False | 950.0 | 0 |
3612248 | 131290 | None | 030 | 1.5 sqmm | Mtr | 26.0 | 26.0 | 100.0 | False | None | None | False | None | False | 2600.0 | 0 |
3612249 | 131290 | None | 031 | 2.5 sqmm | Mtr | 42.0 | 42.0 | 250.0 | False | None | None | False | None | False | 10500.0 | 0 |
3612250 | 131290 | None | 032 | 4 sqmm | Mtr | 63.0 | 63.0 | 120.0 | False | None | None | False | None | False | 7560.0 | 0 |
3612251 | 131290 | None | 033 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (PWD Electrical SR 2023-24 P.No: 8 I.No:3.4) 8 Way | Each | 261.0 | 261.0 | 1.0 | False | None | None | False | None | False | 261.0 | 0 |
3612252 | 131290 | None | 034 | 10-12 Way | Each | 319.0 | 319.0 | 1.0 | False | None | None | False | None | False | 319.0 | 0 |
3612253 | 131290 | None | 035 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. 8 Module (PWD Electrical SR 2023-24 P.No:8 I.No:3.5.1) | Each | 284.0 | 284.0 | 1.0 | False | None | None | False | None | False | 284.0 | 0 |
3612254 | 131290 | None | 036 | 10-12 Module | Each | 344.0 | 344.0 | 1.0 | False | None | None | False | None | False | 344.0 | 0 |
3612255 | 131290 | None | 037 | Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 (PWD Electrical SR 2023-24 P.No:9 I.No:3.6)
6 Amps one way Switch | Each | 102.0 | 102.0 | 12.0 | False | None | None | False | None | False | 1224.0 | 0 |
3612256 | 131290 | None | 038 | 16 Amps one way Switch | Each | 180.0 | 180.0 | 3.0 | False | None | None | False | None | False | 540.0 | 0 |
3612257 | 131290 | None | 039 | 6/16 Amps Universal Socket | Each | 236.0 | 236.0 | 3.0 | False | None | None | False | None | False | 708.0 | 0 |
3612258 | 131290 | None | 040 | Stepped fan regulator Two Module | Each | 357.0 | 357.0 | 2.0 | False | None | None | False | None | False | 714.0 | 0 |
3612259 | 131290 | None | 041 | Supplying and fixing miniature circuit breakers on existence MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. (PWD Electrical SR 2023-24 P.No:17 I.No:5.18) 6-32 Amps SP | Each | 415.0 | 415.0 | 3.0 | False | None | None | False | None | False | 1245.0 | 0 |
3612260 | 131290 | None | 042 | 6-32 Amps DP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 |
3612261 | 131290 | None | 043 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure. 12 Way SP & N Single Door (PWD Electrical SR 2023-24 P.No:18 I.No:5.19.4) | Each | 1863.0 | 1863.0 | 1.0 | False | None | None | False | None | False | 1863.0 | 0 |
3612262 | 131290 | None | 044 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cutouts & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 6ft. Copper bonded rod with backfill compound (PWD Electrical SR 2023-24 P.No:55 I.No:12.60.2) | Kit | 6230.0 | 6230.0 | 1.0 | False | None | None | False | None | False | 6230.0 | 0 |
3612263 | 131290 | None | 045 | Supplying of Grounding Material Bentonite clay slurry for earthing in 50 Kg Bag ESCOMs SR 2023-24 P.No:23 Sl.No:393 I.No:51.05) | Bag | 368.0 | 368.0 | 2.0 | False | None | None | False | None | False | 736.0 | 0 |
3612264 | 131290 | None | 046 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper Strip (PWD Electrical SR 2023-24 P.No:54 I.No:12.58.7) | Mtr | 570.0 | 570.0 | 8.0 | False | None | None | False | None | False | 4560.0 | 0 |
3612265 | 131290 | None | 047 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20 A single phase Class-1 Accuracy with Temper Proof Energy Meter. (PWD Electrical SR 2023-24 P.No:19 I.No:5.30) | Each | 1380.0 | 1380.0 | 1.0 | False | None | None | False | None | False | 1380.0 | 0 |
3612266 | 131290 | None | 048 | Supplying of LT Metering Box for housing the ETV Meter without CT's busbar wiring etc (ESCOMs SR 2023-24 P.No:25 Sl.No:428 I.No:55.04) | Unit | 3644.0 | 3644.0 | 1.0 | False | None | None | False | None | False | 3644.0 | 0 |
3612267 | 131290 | None | 049 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm ) Regular model (PWD Electrical SR 2023-24 P.No:30 I.No:6.3.1) | Each | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 |
3612268 | 131290 | None | 050 | Supply and fixing of 4 pole contactor with NO/NC contacts on existing wood/ panel board using necessary bolts, nitsm washers and wiring etc, complete with AC-3 rating and as per IS- 13947. 40 Amps (PWD Electrical SR 2023-24 P.No:15 I.No:5.13.2) | Each | 2258.0 | 2258.0 | 1.0 | False | None | None | False | None | False | 2258.0 | 0 |
3612269 | 131290 | None | 051 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input : 220-240V @ 50/60 Hz & power factor greater than 0.9 along with CE approved. 2 years warranty against any manufacturing defect working under standard lectrical condition. LED light fitting 1x4' - 20/22 W (PWD Electrical SR 2023-24 P.No:43 I.No:11.3.2) | Each | 690.0 | 690.0 | 6.0 | False | None | None | False | None | False | 4140.0 | 0 |
3612270 | 131290 | None | 052 | LED light fitting 1 x 4' - 36/40 W (PWD Electrical SR 2023-24 P.No:43 I.No:11.3.2) | Each | 1269.0 | 1269.0 | 1.0 | False | None | None | False | None | False | 1269.0 | 0 |
3612271 | 131290 | None | 053 | Fixing all types and all capacities fluorescent /false ceiling/spot light/CFL/LED fittings indoor on the wall / ceiling / rafters / girders using 23 / 0.00076 " twin twisted PVC insulated wires, required nos of round blocks and clamps. On wall / ceiling / Rafters / Girders (PWD Electrical SR 2023-24 P.No:56 I.No:13.7.1) | Each | 122.0 | 122.0 | 7.0 | False | None | None | False | None | False | 854.0 | 0 |
3612272 | 131290 | None | 054 | Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together supplying and fixing a 5 amps ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. (PWD Electrical SR 2023-24 P.No:57 I.No:13.10) | Each | 171.0 | 171.0 | 2.0 | False | None | None | False | None | False | 342.0 | 0 |