| 1721979962000 | 0 | None | None | Buildings | Construction of muslim jamat community bhavan and Devlopment of moulali and hiredevar Bhavan in managuli | 1889454.49 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3627113 | 131846 | None | code01 | Earth Work Excavation Mechanical :Earth work excavation for Foundation by mechanical means for all works & depth up to 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift up to 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work ( In all kinds of soils Depth upto 3 m) | Cum | 105.06 | 105.06 | 8.64 | False | None | None | False | None | False | 907.7184 | 0 | | 3627114 | 131846 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6168.67 | 6168.67 | 0.72 | False | None | None | False | None | False | 4441.4424 | 0 | | 3627115 | 131846 | None | code03 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates | Cum | 6475.61 | 6475.61 | 1.7799 | False | None | None | False | None | False | 11525.938239 | 0 | | 3627116 | 131846 | None | code04 | Form Work As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For Footing. consider 8% | Cum | 518.05 | 518.05 | 1.5 | False | None | None | False | None | False | 777.075 | 0 | | 3627117 | 131846 | None | code05 | Providing and laying in position Reinforced cement concrete for all superstructures of building, Road works, Water works, Irrigation works & superstructure works of bridges upto 3.50m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes,labour,Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) -do- M20 Design Mix Using 20mm nominal size graded crushed coarse aggregates | Cum | 6828.9 | 6828.9 | 9.6617 | False | None | None | False | None | False | 65978.78313 | 0 | | 3627118 | 131846 | None | code06 | Form Work As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For Staircase and other similar structures 50% | Cum | 3237.8 | 3237.8 | 9.7217 | False | None | None | False | None | False | 31476.92026 | 0 | | 3627119 | 131846 | None | code07 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 81381.33 | 81381.33 | 1.11 | False | None | None | False | None | False | 90333.2763 | 0 | | 3627120 | 131846 | None | code08 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8217.34 | 8217.34 | 21.31 | False | None | None | False | None | False | 175111.5154 | 0 | | 3627121 | 131846 | None | code09 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of
Engineer-in-charge. | Sqm | 248.23 | 248.23 | 662.88 | False | None | None | False | None | False | 164546.7024 | 0 | | 3627122 | 131846 | None | code10 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 91.67 | 91.67 | 662.88 | False | None | None | False | None | False | 60766.2096 | 0 | | 3627123 | 131846 | None | code11 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 2937.56 | 2937.56 | 181.25 | False | None | None | False | None | False | 532432.75 | 0 | | 3627124 | 131846 | None | code12 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 142216.22 | 142216.22 | 0.24 | False | None | None | False | None | False | 34131.8928 | 0 | | 3627125 | 131846 | None | code13 | Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 35mm. thick with bottom and lock rails
180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 7297.55 | 7297.55 | 6.09 | False | None | None | False | None | False | 44442.0795 | 0 | | 3627126 | 131846 | None | code14 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size,with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 8524.28 | 8524.28 | 11.43 | False | None | None | False | None | False | 97432.5204 | 0 | | 3627127 | 131846 | None | code15 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 2343.25 | 2343.25 | 37.77 | False | None | None | False | None | False | 88504.5525 | 0 | | 3627128 | 131846 | None | code16 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per
specifications and as per directions of the Engineer-in-Charge. | Kg | 123.6 | 123.6 | 257.669 | False | None | None | False | None | False | 31847.8884 | 0 | | 3627129 | 131846 | None | code17 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge | Sqm | 54.59 | 54.59 | 662.88 | False | None | None | False | None | False | 36186.6192 | 0 | | 3627130 | 131846 | None | code18 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life | Sqm | 162.74 | 162.74 | 662.88 | False | None | None | False | None | False | 107877.0912 | 0 | | 3627131 | 131846 | None | code19 | Painting with oil type wood preservative of approved brand and manu facture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer- | Sqm | 41.2 | 41.2 | 6.09 | False | None | None | False | None | False | 250.908 | 0 | | 3627132 | 131846 | None | code20 | Varnishing with varnish of approved brand and manufacture: One coats with spar varnish including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer in-charge | Sqm | 71.07 | 71.07 | 49.2 | False | None | None | False | None | False | 3496.644 | 0 | | 3627133 | 131846 | None | code21 | Providing fixing of 2 track 2 panel sliding windows made out of multi chambered UPVC sections and with minimum TiO2 at 6 PHR with TPE and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-honeycomb structure inside in lieu of GI UPVC | Sqm | 5173.69 | 5173.69 | 13.34 | False | None | None | False | None | False | 69017.0246 | 0 | | 3627134 | 131846 | None | code22 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery
complete as per specifications and as per directions of the Engineer-in Charge.Angle size 25x25x5.0mm Weight-1.65kg/m | Kg | 140.08 | 140.08 | 145.2 | False | None | None | False | None | False | 20339.616 | 0 | | 3627135 | 131846 | None | code23 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of urlins, rafters and trusses and including cutting to size and shape wherever required as per the irection of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m² | Sqm | 905.37 | 905.37 | 36.0 | False | None | None | False | None | False | 32593.32 | 0 | | 3627136 | 131846 | None | code24 | Concealed Conduit System: Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 19/20 mm dia 2 mm thick | m | 66.0 | 66.0 | 130.0 | False | None | None | False | None | False | 8580.0 | 0 | | 3627137 | 131846 | None | code25 | Short point upto 3m from tapping point to out let via switch | Point | 285.0 | 285.0 | 13.0 | False | None | None | False | None | False | 3705.0 | 0 | | 3627138 | 131846 | None | code26 | Medium point above 3m upto 6m from tapping point to out let via switch | Point | 394.0 | 394.0 | 20.0 | False | None | None | False | None | False | 7880.0 | 0 | | 3627139 | 131846 | None | code27 | 1.5 mm2 | m | 26.0 | 26.0 | 230.0 | False | None | None | False | None | False | 5980.0 | 0 | | 3627140 | 131846 | None | code28 | 2.5 mm2 | m | 42.0 | 42.0 | 80.0 | False | None | None | False | None | False | 3360.0 | 0 | | 3627141 | 131846 | None | code29 | 1-3 Way | Each | 138.0 | 138.0 | 10.0 | False | None | None | False | None | False | 1380.0 | 0 | | 3627142 | 131846 | None | code30 | 6 Way | Each | 220.0 | 220.0 | 6.0 | False | None | None | False | None | False | 1320.0 | 0 | | 3627143 | 131846 | None | code31 | 1 to 3 Module | Each | 137.0 | 137.0 | 12.0 | False | None | None | False | None | False | 1644.0 | 0 | | 3627144 | 131846 | None | code32 | 4 Module | Each | 175.0 | 175.0 | 4.0 | False | None | None | False | None | False | 700.0 | 0 | | 3627145 | 131846 | None | code33 | 6 Module | Each | 234.0 | 234.0 | 6.0 | False | None | None | False | None | False | 1404.0 | 0 | | 3627146 | 131846 | None | code34 | 6Amps One Way Switch | Each | 102.0 | 102.0 | 40.0 | False | None | None | False | None | False | 4080.0 | 0 | | 3627147 | 131846 | None | code35 | 6A Three Way socket | Each | 166.0 | 166.0 | 20.0 | False | None | None | False | None | False | 3320.0 | 0 | | 3627148 | 131846 | None | code36 | Stepped Fan Regulator Two Module | Each | 276.0 | 276.0 | 8.0 | False | None | None | False | None | False | 2208.0 | 0 | | 3627149 | 131846 | None | code37 | 6/16A Universal Socket | Each | 236.0 | 236.0 | 6.0 | False | None | None | False | None | False | 1416.0 | 0 | | 3627150 | 131846 | None | code38 | 32A DP Switch | Each | 326.0 | 326.0 | 6.0 | False | None | None | False | None | False | 1956.0 | 0 | | 3627151 | 131846 | None | code40 | 6A Bakelite Ceiling Rose | No | 78.0 | 78.0 | 45.0 | False | None | None | False | None | False | 3510.0 | 0 | | 3627152 | 131846 | None | code41 | 6A Lamp Holder | No | 71.0 | 71.0 | 15.0 | False | None | None | False | None | False | 1065.0 | 0 | | 3627153 | 131846 | None | code42 | Supplying & fixing of retrofit type - LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI70 efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated 12W, 6500K | Each | 269.0 | 269.0 | 50.0 | False | None | None | False | None | False | 13450.0 | 0 | | 3627154 | 131846 | None | code43 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 8.0 | False | None | None | False | None | False | 23872.0 | 0 | | 3627155 | 131846 | None | code44 | Supply of LED Streetlight luminaire with pressure die cast aluminum housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection molded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70, maximum light intensity should be between 60 degrees to 70 degrees. C. LED Streetlight 90 W | No | 5992.0 | 5992.0 | 3.0 | False | None | None | False | None | False | 17976.0 | 0 | | 3627156 | 131846 | None | code45 | Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket 1x40/2x40 W fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clA, bolts, and nuts and wiring using suitable capacity wires. Using 32mm dia G.I.Pipe | Each | 1045.0 | 1045.0 | 3.0 | False | None | None | False | None | False | 3135.0 | 0 | | 3627157 | 131846 | None | code46 | Fixing all types and all capacities of fluorescent /false ceiling /spot light / CFL / LED fittings indoor on the wall/ ceiling /rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 24.0 | False | None | None | False | None | False | 2928.0 | 0 | | 3627158 | 131846 | None | code47 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 315.0 | 315.0 | 8.0 | False | None | None | False | None | False | 2520.0 | 0 | | 3627159 | 131846 | None | code48 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. | Each | 6086.0 | 6086.0 | 3.0 | False | None | None | False | None | False | 18258.0 | 0 | | 3627160 | 131846 | None | code49 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT | Each | 1703.0 | 1703.0 | 3.0 | False | None | None | False | None | False | 5109.0 | 0 | | 3627161 | 131846 | None | code50 | 6-32 Amps SP | Each | 415.0 | 415.0 | 20.0 | False | None | None | False | None | False | 8300.0 | 0 | | 3627162 | 131846 | None | code51 | 6-32 Amps DP | Each | 739.0 | 739.0 | 20.0 | False | None | None | False | None | False | 14780.0 | 0 | | 3627163 | 131846 | None | code52 | 6-32 Amps TPN | Each | 1717.0 | 1717.0 | 8.0 | False | None | None | False | None | False | 13736.0 | 0 | | 3627164 | 131846 | None | code53 | G I Grounding pipe, B-Class, 42 mm dia, 2.50 Mtr long, 3.2 mm thick with bolt, nut, GI strips and washers complete . Minimum weight of GI pipe : 7.3 Kg. | No | 743.0 | 743.0 | 3.0 | False | None | None | False | None | False | 2229.0 | 0 | | 3627165 | 131846 | None | code54 | Good quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each. | No | 676.0 | 676.0 | 3.0 | False | None | None | False | None | False | 2028.0 | 0 | | 3627166 | 131846 | None | code55 | Good quality Salt for grounding purposes packed in 50 Kg gunny bag. | Bag | 310.0 | 310.0 | 3.0 | False | None | None | False | None | False | 930.0 | 0 | | 3627167 | 131846 | None | code56 | Digging pit for G I Pipe tye earthing in Hard soil | Per Pit | 759.0 | 759.0 | 3.0 | False | None | None | False | None | False | 2277.0 | 0 |
|