createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721979021551
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1000.00
emd80000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose03-08-2024 17:00:00
tenderQueryClose27-07-2024 15:00:00
technicalBidOpenNone
publishedDate26-07-2024 13:08:01
publishedByPostKKRTC_EE_HOFF_BLR
publishedByUserKPE10109 - M ERESH
bidValidityPeriod90
noOfCalls1
preBidMeetingDate29-07-2024 12:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSri.M.Eresh
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber8392294828
mobileNumber9972039797
tenderSupplierListNone
tenderSchedule
createdTs1721979021584
version4
createdDateNone
modifiedDateNone
tenderNumberKKRTC/2024-25/BD/WORK_INDENT72
titleConstruction of Modal Toilet in Bus Station at Siruguppa.(Ballari District)
descriptionConstruction of Modal Toilet in Bus Station at Siruguppa.(Ballari District)
categoryWORKS
categoryTextWorks
ecv4000000.00
deptNameKalyana Karnataka Road Transport Corporation
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location5937
locationNameKKRTC Divisional Controller Office Bellari
provisionalAmount4000000.0
groupOverheadTotal141438.28
fileNumber00035
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17219790220000NoneNoneBuildingsConstruction of Modal Toilet in Bus Station at Siruguppa.(Ballari District)3858561.72
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3626728131835Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as perdrawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.SRP- Vol-I (8/1.14.1) Depth up to 3 m.Cum126.37126.37136.88FalseNoneNoneFalseNoneFalse17297.52560
3626729131835Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances requiredcomplete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately).SRP- Vol-I (16/2.1.2) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum7017.697017.6923.21FalseNoneNoneFalseNoneFalse162880.58490
3626730131835Nonecode03Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (16/2.4.1) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregatesCum7934.557934.553.0FalseNoneNoneFalseNoneFalse23803.650
3626731131835Nonecode04Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.1.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8412.768412.7612.15FalseNoneNoneFalseNoneFalse102215.0340
3626732131835Nonecode05Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (16/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum13964.7613964.766.26FalseNoneNoneFalseNoneFalse87419.39760
3626733131835Nonecode06Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (16/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum13143.3113143.3113.7FalseNoneNoneFalseNoneFalse180063.3470
3626734131835Nonecode07Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (16/2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12321.8512321.8515.64FalseNoneNoneFalseNoneFalse192713.7340
3626735131835Nonecode08KSRB 2.3 : Filling (new earth )Refilling available earth around trenches/pipelines, cables in layersnot exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m .Including cost of all labour complete as per specifications.SRP- Vol-I (7/1.10)Cum520.38520.3898.12FalseNoneNoneFalseNoneFalse51059.68560
3626736131835Nonecode09Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SRP Vol-I(18/2.11a)Kg110.82110.826049.46FalseNoneNoneFalseNoneFalse670401.15720
3626737131835Nonecode10Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.SRP- Vol-II (14/6.8)Cum9873.599873.5934.57FalseNoneNoneFalseNoneFalse341330.00630
3626738131835Nonecode11Providing half brick Masonary with common burnt clay non modular bricks of class designation 3.5 in Foundation and plinth in Cement morter 1;4 (1 cement ;4 coarse sand ) including Cost of all materials SRP-Vol-2(14/6.13)Sqm1209.261209.2628.35FalseNoneNoneFalseNoneFalse34282.5210
3626739131835Nonecode12Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.2)Sqm365.5365.5209.44FalseNoneNoneFalseNoneFalse76550.320
3626740131835Nonecode13Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (41/8.2.2)Sqm315.94315.94208.46FalseNoneNoneFalseNoneFalse65860.85240
3626741131835Nonecode14Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. SRP- Vol-II (104/12.54)Rmtr394.0394.079.8FalseNoneNoneFalseNoneFalse31441.20
3626742131835Nonecode15Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.SRP- Vol-II (104/12.55.2) with one side prelam.Sqm2527.562527.5622.05FalseNoneNoneFalseNoneFalse55732.6980
3626743131835Nonecode16Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.SRP- Vol-II (86/34A)Kg208.15208.15917.9FalseNoneNoneFalseNoneFalse191060.8850
3626744131835Nonecode17Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (91/11.44)Sqm5383.455383.4512.6FalseNoneNoneFalseNoneFalse67831.470
3626745131835Nonecode18Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. SRP- Vol-II (64/9.30)Sqm3199.093199.098.91FalseNoneNoneFalseNoneFalse28503.89190
3626746131835Nonecode19Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-charge. SRP- Vol-II (68/10.2)Rmtr406.39406.3918.3FalseNoneNoneFalseNoneFalse7436.9370
3626747131835Nonecode20Constructing brick maconary inspection chamber of internal dimention 600 X 450 mm, and depth of 600mm ( Inner dimension ) with modular bricks of class designation 75 in Cm 1:6 bed concrete 150mm thick with 1:3:6 with plastering 12 mm thick with CM 1:4.CC 1:2:4 cooping 75mm thick for fixing CI cover & frame etc.(excluding cost of CI frame & cover). SRP- Vol-V 126/8/T130AEach6990.436990.4310.0FalseNoneNoneFalseNoneFalse69904.30
3626748131835Nonecode21Supplying and laying at site Factory made perforated hard HDPE subsoil drainage pipes pre-wrapped with 150 gsm Geotextile for subsoil drainage system including all necessary coupling/ fittings for joints & back filling with aggregates. The pipe shall be manufactured from High Density Polyethylene (HDPE). It shall be extruded into an open lattice wall structure, with greater-than 60 personage of the circumference consisting of open area and a 30% solid area along the invert. The product should satisfy the following parameters as below 1. Ring Stiffness as per ISO 9969: 2016 should be greater-than 0.8 kN/m2 2. Resistance to Acid with 3 personage HCl for 24 hrs without mass loss, change in colour softening cracking or spalling. Resistance to Alkali with 3% KOH for 24 hrs without without mass loss, change in colour, softening, cracking or spalling. (Excavated material to be utlised in roadway at site) SRPVol-III 19 / 3.14Rmtr385.32385.3280.0FalseNoneNoneFalseNoneFalse30825.60
3626749131835Nonecode22Supplying, lowering, laying, jointing, testing and commissioning of Glazed Stone Ware Pipes of following dia, conforming to IS 651:1992,IS 4127 with latest amendments, including conveying to work site,caulking with hemp dipped in tar and jointing with CM 1:1.5 using OPC, perfect linking and curing for 10 days and testing with water etc. with all lead, lifts and as per Technical Specifications. The cost to include the cost of all jointing materials, necessary survey works for laying of sewer lines etc. complete. The contractor will make own arrangements for procuring water for testing.150 mm dia. pipes SRP- Vol-V 184/2.2/T040BRmtr633.12633.1235.0FalseNoneNoneFalseNoneFalse22159.20
3626750131835Nonecode23Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (48/8.40)Sqm139.39139.3925.0FalseNoneNoneFalseNoneFalse3484.750
3626751131835Nonecode24Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SRP- Vol-II (48/8.25)Sqm178.1178.1100.0FalseNoneNoneFalseNoneFalse17810.00
3626752131835Nonecode25Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. (Apex Paint) SRP- Vol-II (45/8.28)Sqm137.83137.83200.0FalseNoneNoneFalseNoneFalse27566.00
3626753131835Nonecode26Providing and Placing on terrace (at all floot Levels) Polythylene water storage tank IS 12701 marked with cover and sutable locking arrangementsand making necessery holes for inlet, outlet and overflow pipes but without fittings and the base support for tank SRP Vol-II ( 9/13.34)Ltr11.1511.158000.0FalseNoneNoneFalseNoneFalse89200.00
3626754131835Nonecode27Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall vOl-11/122/13.31 40 mm diaMtr664.1664.1120.0FalseNoneNoneFalseNoneFalse79692.00
3626755131835Nonecode28Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall vOl-11/122/13.31 25 mm diaMtr397.75397.7540.0FalseNoneNoneFalseNoneFalse15910.00
3626756131835Nonecode29Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall vOl-11/122/13.31 20 mm diaMtr299.83299.8335.0FalseNoneNoneFalseNoneFalse10494.050
3626757131835Nonecode30Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall vOl-11/122/13.31 15 mm diaMtr225.49225.4918.0FalseNoneNoneFalseNoneFalse4058.820
3626758131835Nonecode31White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap SRP- Vol-II (133/14.7.7)Nos2600.662600.663.0FalseNoneNoneFalseNoneFalse7801.980
3626759131835Nonecode32Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required. SRP- Vol-II (131/14.3.2) W.C. pan with ISI marked black solid plastic seat and lid.Each7192.397192.393.0FalseNoneNoneFalseNoneFalse21577.170
3626760131835Nonecode33Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required SRP- Vol-II (138/14.1.1)White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.Nos2888.12888.16.0FalseNoneNoneFalseNoneFalse17328.60
3626761131835Nonecode34Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern. with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single Half stall urinals with 5 litre P.V.C. automatic flushing cistern Vol II/132/14.5.1Each10707.4310707.438.0FalseNoneNoneFalseNoneFalse85659.440
3626762131835Nonecode35KSRB 11-15.4 : Providing and fixing 450 x 350mm dia oval shape mirror with plastic moulded frame of approved make and shade with 6mm thick hard board backig including cost of materials, labour complete as per specifications. SRP 136/14.32.3Unit1320.771320.772.0FalseNoneNoneFalseNoneFalse2641.540
3626763131835Nonecode36Providing and fixing C I Nahani trap of approved make confirming to ISI specifications and construction of cistern in CC 1:2:4 as per directions (Inclusive of cost of materials and fixtures) 12.5 cms x 7.5 cms SRP 90 / 12.113.2Each336.3336.38.0FalseNoneNoneFalseNoneFalse2690.40
3626764131835Nonecode37Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. 15 mm nominal bore SRP- Vol-II (117/13.5.1)Nos366.74366.744.0FalseNoneNoneFalseNoneFalse1466.960
3626765131835Nonecode38Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 40 mm nominal bore SRP- Vol-II (117/13.4.3)Nos740.92740.924.0FalseNoneNoneFalseNoneFalse2963.680
3626766131835Nonecode39Providing and fixing brass stop cock of approved quality 15 mm nominal bore SRP- Vol-II (117/13.3.1)Nos370.46370.4618.0FalseNoneNoneFalseNoneFalse6668.280
3626767131835Nonecode40Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. SRP- Vol-II (60/9.11)Sqm1101.471101.4772.0FalseNoneNoneFalseNoneFalse79305.840
3626768131835Nonecode41Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. SRP- Vol-II (65/9.38)Sqm1724.681724.68130.88FalseNoneNoneFalseNoneFalse225726.11840
3626769131835Nonecode42Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification.SRP- Vol-II (65/9.40)Sqm1154.741154.7428.5FalseNoneNoneFalseNoneFalse32910.090
3626770131835Nonecode43Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing,polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SRP- Vol-II (83/11.28)Kg700.03700.0375.6FalseNoneNoneFalseNoneFalse52922.2680
3626771131835Nonecode44Polyurethane based single component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace or Chajjas or Sunken portion of WC Bathroom cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400 personage and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in two coats at 1.6 kg/ m square to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer at 150 g/ m square and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation making coving at Junction Bore Packing treatment of construction joints completely as per specification. Vol II/149/15.1Sqm1012.261012.26104.25FalseNoneNoneFalseNoneFalse105528.1050
3626772131835Nonecode45Hydraulic Excavator of 0.9 m3 bucket (J.C.B excavator) Levelling the ground 2021-22 SRP- Vol-I (A-45/50)Sqm9356.929356.923.0FalseNoneNoneFalseNoneFalse28070.760
3626773131835Nonecode46Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories,sealing shall be done with necessary rods etc., complete SRP- Vol-II (71/10.15.1)Sqm4880.424880.4210.0FalseNoneNoneFalseNoneFalse48804.20
3626774131835Nonecode47Misl , Consultency charges and Rounding OffLS1.181.18662.0FalseNoneNoneFalseNoneFalse781.160
3626775131835Nonecode48Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications Vol-1 SRP 7/1.10Cum198.24198.243.94FalseNoneNoneFalseNoneFalse781.06560
3626776131835Nonecode49Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances requiredcomplete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately).SRP- Vol-I (16/2.1.2) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum8214.578214.573.94FalseNoneNoneFalseNoneFalse32365.40580
3626777131835Nonecode50Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (15/2.2.1.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7789.597789.5918.45FalseNoneNoneFalseNoneFalse143717.93550
3626778131835Nonecode51Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick (1.2.1/2 of 105)Mtr81.7781.77200.0FalseNoneNoneFalseNoneFalse16354.00
3626779131835Nonecode52Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick (1.2.2/2 of 105)Mtr96.6496.64400.0FalseNoneNoneFalseNoneFalse38656.00
3626780131835Nonecode53Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 20 mm dia 2 mm thick (1.3.1/ 2of105 )Mtr84.2584.2530.0FalseNoneNoneFalseNoneFalse2527.50
3626781131835Nonecode54Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 25 mm dia 2 mm thick (1.3.2/ 2of105 )Mtr97.8897.8875.0FalseNoneNoneFalseNoneFalse7341.00
3626782131835Nonecode55Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box (2.2.1/5 of 105)Point333.29333.295.0FalseNoneNoneFalseNoneFalse1666.450
3626783131835Nonecode56Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box .(2.2.1/5 of 105)Point469.58469.588.0FalseNoneNoneFalseNoneFalse3756.640
3626784131835Nonecode57Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box (2.2.3/5 of 105)Point687.64687.6414.0FalseNoneNoneFalseNoneFalse9626.960
3626785131835Nonecode58Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 sqmm wire (2.3.3/5 of 105)Mtr52.0352.03300.0FalseNoneNoneFalseNoneFalse15609.00
3626786131835Nonecode59Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 sqmm wire (2.3.2/ 5 of 105)Mtr32.2132.21500.0FalseNoneNoneFalseNoneFalse16105.00
3626787131835Nonecode60Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 6 sqmm wire (2.3.5/5 of 105)Mtr113.98113.9850.0FalseNoneNoneFalseNoneFalse5699.00
3626788131835Nonecode61Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 sqmm wire (2.3.4/5 of 105)Mtr78.0578.05200.0FalseNoneNoneFalseNoneFalse15610.00
3626789131835Nonecode62Supplying of feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater-than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater-than 0.9 along with CE approved 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W (11.3.2/43 of 105)Each854.91854.9120.0FalseNoneNoneFalseNoneFalse17098.20
3626790131835Nonecode63Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps .On wall/ ceiling / Rafter / Girders (13.7.1/56 of 105Each151.15151.1520.0FalseNoneNoneFalseNoneFalse3023.00
3626791131835Nonecode64Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 way (3.4.3/8of 105)Each219.3219.32.0FalseNoneNoneFalseNoneFalse438.60
3626792131835Nonecode65Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 way (3.4.4/8 of 105)Each272.58272.584.0FalseNoneNoneFalseNoneFalse1090.320
3626793131835Nonecode66Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 way (3.4.5/ 8 of 105)Each323.37323.376.0FalseNoneNoneFalseNoneFalse1940.220
3626794131835Nonecode67Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 way (3.4.6/ 8 of 105)Each395.24395.244.0FalseNoneNoneFalseNoneFalse1580.960
3626795131835Nonecode68Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 18 way (3.4.8/ 8 of 105)Each501.79501.792.0FalseNoneNoneFalseNoneFalse1003.580
3626796131835Nonecode69Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module (3.5.3/ 8 of 105)Each216.82216.822.0FalseNoneNoneFalseNoneFalse433.640
3626797131835Nonecode70Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module (3.5.4/ 8 of 105)Each289.92289.924.0FalseNoneNoneFalseNoneFalse1159.680
3626798131835Nonecode71Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module (3.5.5/ 8 of 105)Each351.87351.876.0FalseNoneNoneFalseNoneFalse2111.220
3626799131835Nonecode72Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module (3.5.6/ 8 of 105)Each426.21426.214.0FalseNoneNoneFalseNoneFalse1704.840
3626800131835Nonecode73Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 18 Module (3.5.8/8 of 105)Each566.22566.222.0FalseNoneNoneFalseNoneFalse1132.440
3626801131835Nonecode74Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket (3.6.3/9 of 105)Each211.86211.8610.0FalseNoneNoneFalseNoneFalse2118.60
3626802131835Nonecode75Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch (3.6.1/ 8 of 105)Each126.37126.3750.0FalseNoneNoneFalseNoneFalse6318.50
3626803131835Nonecode76Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch (3.6.7/ 8 of 105)Each223.01223.014.0FalseNoneNoneFalseNoneFalse892.040
3626804131835Nonecode77Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket (3.6.10/9 of 105)Each292.4292.44.0FalseNoneNoneFalseNoneFalse1169.60
3626805131835Nonecode78Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch (3.6.9/ 9 of105)Each403.91403.914.0FalseNoneNoneFalseNoneFalse1615.640
3626806131835Nonecode79Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DP (5.18.4/17 of105)Each915.62915.623.0FalseNoneNoneFalseNoneFalse2746.860
3626807131835Nonecode80Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A TPN (5.148.7/17 of 105)Each2127.362127.362.0FalseNoneNoneFalseNoneFalse4254.720
3626808131835Nonecode81Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps SP (5.18.1/ 17 of 105)Each514.18514.184.0FalseNoneNoneFalseNoneFalse2056.720
3626809131835Nonecode821.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 5 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) (201/32.05/13 of 81)Km175742.23175742.230.05FalseNoneNoneFalseNoneFalse8787.11150
3626810131835Nonecode83Optical Fibre Cable (OFC) and its Accessories HDPE/PLB Pipe 50/42 mm (536/66.04/30 of 81)Km105332.34105332.340.04FalseNoneNoneFalseNoneFalse4213.29360
3626811131835Nonecode84Aluminium End Terminal (Lug) 16 sqmm (470/60.02/27 of 81)No2.472.478.0FalseNoneNoneFalseNoneFalse19.760
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17219790220000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17219790220000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17219790220000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17219790220000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17219790220000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17219790220000NoneNoneELIGIBILITYMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)None
17219790220000NoneNoneELIGIBILITYSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)None
17219790220000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17219790220000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNone
17219790220000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17219790220000NoneNoneELIGIBILITYList of existing commitments and ongoing worksNone
17219790220000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17219790220000NoneNoneELIGIBILITYBanker Details for referenceNone
17219790220000NoneNoneELIGIBILITYConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNone
17219790220000NoneNoneELIGIBILITYReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNone
17219790220000NoneNoneELIGIBILITYQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNone
17219790220000NoneNoneELIGIBILITYProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)None
17219790320000NoneNoneELIGIBILITYEstimated Rates inclusive of all applicable taxes including GST.None
17219790380000NoneNoneELIGIBILITYThe bidder shall quote their rates inclusive of all applicable taxes and inclusive of GST.None
17219790450000NoneNoneELIGIBILITYGST will not be paid separately. It is added in the individual items rates.None
17219790520000NoneNoneELIGIBILITYTERMS AND CONDITIONS AS PER TENDER NOTIFICATIONNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Upload a Scanned copy of attested Valid contractors Registration Certificate as per tender notification Eligibility CriteriaFalseTechnical Bid
Upload a Scanned copy of work done one work of similar nature / Building as per tender notification Eligibility CriteriaFalseTechnical Bid
Upload a Scanned copy of Annual Financial Turnover audited balance sheet and profit & loss accounts statement certified by a Chartered Accountant as per tender notification Eligibility CriteriaFalseTechnical Bid
Upload a Scanned copy of self declaration certificate as per tender notification Eligibility CriteriaFalseTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1721979259000
version0
createdDateNone
modifiedDateNone
blockNumberO/o the EE KKRTC Near SP Circle Ballari
streetNone
cityBallari
stateKarnataka
pin583102
tenderRecallDTONone