| 3622595 | 131618 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 254.1 | 254.1 | 75.27 | False | None | None | False | None | False | 19126.107 | 0 |
| 3622596 | 131618 | None | code02 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m | Cum | 271.95 | 271.95 | 22.82 | False | None | None | False | None | False | 6205.899 | 0 |
| 3622597 | 131618 | None | code03 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 7.15 | False | None | None | False | None | False | 44962.4175 | 0 |
| 3622598 | 131618 | None | code04 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6852.38 | 6852.38 | 12.29 | False | None | None | False | None | False | 84215.7502 | 0 |
| 3622599 | 131618 | None | code05 | Additional for Formwork, Centering & Scaffolding for Columns | Cum | 11309.76 | 11309.76 | 1.74 | False | None | None | False | None | False | 19678.9824 | 0 |
| 3622600 | 131618 | None | code06 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12214.76 | 12214.76 | 4.77 | False | None | None | False | None | False | 58264.4052 | 0 |
| 3622601 | 131618 | None | code07 | Additional for Formwork, Centering & Scaffolding for Beams | Cum | 10777.73 | 10777.73 | 14.03 | False | None | None | False | None | False | 151211.5519 | 0 |
| 3622602 | 131618 | None | code08 | Additional for Formwork, Centering & Scaffolding for Beams | Cum | 11496.24 | 11496.24 | 9.0 | False | None | None | False | None | False | 103466.16 | 0 |
| 3622603 | 131618 | None | code09 | Additional for Formwork, Centering & Scaffolding for Chajjas | Cum | 10418.47 | 10418.47 | 0.28 | False | None | None | False | None | False | 2917.1716 | 0 |
| 3622604 | 131618 | None | code10 | Additional for Formwork, Centering & Scaffolding for slab | Cum | 10777.73 | 10777.73 | 17.56 | False | None | None | False | None | False | 189256.9388 | 0 |
| 3622605 | 131618 | None | code11 | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 93929.85 | 93929.85 | 5.44 | False | None | None | False | None | False | 510978.384 | 0 |
| 3622606 | 131618 | None | code12 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9094.05 | 9094.05 | 4.44 | False | None | None | False | None | False | 40377.582 | 0 |
| 3622607 | 131618 | None | code13 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 31.34 | False | None | None | False | None | False | 262235.883 | 0 |
| 3622608 | 131618 | None | code14 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 53.86 | False | None | None | False | None | False | 15043.098 | 0 |
| 3622609 | 131618 | None | code15 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work. | Cum | 496.52 | 496.52 | 107.8 | False | None | None | False | None | False | 53524.856 | 0 |
| 3622610 | 131618 | None | code16 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4454.1 | 4454.1 | 18.0 | False | None | None | False | None | False | 80173.8 | 0 |
| 3622611 | 131618 | None | code17 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 176.4 | 176.4 | 396.9 | False | None | None | False | None | False | 70013.16 | 0 |
| 3622612 | 131618 | None | code18 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6463.8 | 6463.8 | 10.63 | False | None | None | False | None | False | 68710.194 | 0 |
| 3622613 | 131618 | None | code19 | Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. | Sqm | 2189.25 | 2189.25 | 122.28 | False | None | None | False | None | False | 267701.49 | 0 |
| 3622614 | 131618 | None | code20 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 292.95 | 292.95 | 156.06 | False | None | None | False | None | False | 45717.777 | 0 |
| 3622615 | 131618 | None | code21 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. | Sqm | 349.65 | 349.65 | 224.24 | False | None | None | False | None | False | 78405.516 | 0 |
| 3622616 | 131618 | None | code22 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 87.15 | 87.15 | 268.87 | False | None | None | False | None | False | 23432.0205 | 0 |
| 3622617 | 131618 | None | code23 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 133.35 | 133.35 | 493.11 | False | None | None | False | None | False | 65756.2185 | 0 |
| 3622618 | 131618 | None | code24 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. E.R.W. tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 136.5 | 136.5 | 75.6 | False | None | None | False | None | False | 10319.4 | 0 |
| 3622619 | 131618 | None | code25 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | cm | 4.2 | 4.2 | 1000.0 | False | None | None | False | None | False | 4200.0 | 0 |
| 3622620 | 131618 | None | code26 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter | m | 305.55 | 305.55 | 10.0 | False | None | None | False | None | False | 3055.5 | 0 |
| 3622621 | 131618 | None | code27 | Electrical :Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2mm thick | Mtr | 66.0 | 66.0 | 60.0 | False | None | None | False | None | False | 3960.0 | 0 |
| 3622622 | 131618 | None | code28 | 25mm dia 2mm thick | Mtr | 78.0 | 78.0 | 20.0 | False | None | None | False | None | False | 1560.0 | 0 |
| 3622623 | 131618 | None | code29 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 75x75x65mm | Each | 106.0 | 106.0 | 1.0 | False | None | None | False | None | False | 106.0 | 0 |
| 3622624 | 131618 | None | code30 | 180X90X65mm | Each | 161.0 | 161.0 | 1.0 | False | None | None | False | None | False | 161.0 | 0 |
| 3622625 | 131618 | None | code31 | 200x90x65mm | Each | 179.0 | 179.0 | 3.0 | False | None | None | False | None | False | 537.0 | 0 |
| 3622626 | 131618 | None | code32 | Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction Box | Each | 49.0 | 49.0 | 5.0 | False | None | None | False | None | False | 245.0 | 0 |
| 3622627 | 131618 | None | code33 | 25mm Deep Junction Box | Each | 56.0 | 56.0 | 1.0 | False | None | None | False | None | False | 56.0 | 0 |
| 3622628 | 131618 | None | code34 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50mm Conduit in Brick Walls | Mtr | 29.0 | 29.0 | 30.0 | False | None | None | False | None | False | 870.0 | 0 |
| 3622629 | 131618 | None | code35 | Supplying And Fixing Metal Fan Box with Round Hook. | Nos | 160.0 | 160.0 | 4.0 | False | None | None | False | None | False | 640.0 | 0 |
| 3622630 | 131618 | None | code36 | Point wiring Copper without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing usingf 1100v Grade , COPPER conductor flexible multistrand FRLS PVC insulated., 2x1.5 Sqm. Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood /PVC round block. Complete for each outlet(5/2.3) Group A Short piont up to 3 Mtr from tapping piont out let via switch. | Point | 285.0 | 285.0 | 8.0 | False | None | None | False | None | False | 2280.0 | 0 |
| 3622631 | 131618 | None | code37 | A medium point above 3m to 6 Mtr from tapping piont out | Point | 394.0 | 394.0 | 6.0 | False | None | None | False | None | False | 2364.0 | 0 |
| 3622632 | 131618 | None | code38 | A Short piont up to 10 Mtr from tapping piont out | Point | 570.0 | 570.0 | 2.0 | False | None | None | False | None | False | 1140.0 | 0 |
| 3622633 | 131618 | None | code39 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5sqmm | Mtr | 26.0 | 26.0 | 120.0 | False | None | None | False | None | False | 3120.0 | 0 |
| 3622634 | 131618 | None | code40 | 2.5 Sqmm | Mtr | 42.0 | 42.0 | 10.0 | False | None | None | False | None | False | 420.0 | 0 |
| 3622635 | 131618 | None | code41 | 4 Sqmm | Mtr | 63.0 | 63.0 | 8.0 | False | None | None | False | None | False | 504.0 | 0 |
| 3622636 | 131618 | None | code42 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box. 1 to 3 Module | Each | 161.0 | 161.0 | 2.0 | False | None | None | False | None | False | 322.0 | 0 |
| 3622637 | 131618 | None | code43 | 4 Module | Each | 175.0 | 175.0 | 4.0 | False | None | None | False | None | False | 700.0 | 0 |
| 3622638 | 131618 | None | code44 | 8 Module | Each | 234.0 | 234.0 | 1.0 | False | None | None | False | None | False | 234.0 | 0 |
| 3622639 | 131618 | None | code45 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way | Each | 102.0 | 102.0 | 2.0 | False | None | None | False | None | False | 204.0 | 0 |
| 3622640 | 131618 | None | code46 | 16Amps two way switch | Each | 177.0 | 177.0 | 2.0 | False | None | None | False | None | False | 354.0 | 0 |
| 3622641 | 131618 | None | code47 | 6/16Amps universal socket | Each | 156.0 | 156.0 | 7.0 | False | None | None | False | None | False | 1092.0 | 0 |
| 3622642 | 131618 | None | code48 | Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts,50Hz AC supply & completely wired on existing box. | Each | 646.0 | 646.0 | 1.0 | False | None | None | False | None | False | 646.0 | 0 |
| 3622643 | 131618 | None | code49 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps SP | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 |
| 3622644 | 131618 | None | code50 | 6-32 Amps DP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 |
| 3622645 | 131618 | None | code51 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door 12 Way SP & N | Each | 3088.0 | 3088.0 | 1.0 | False | None | None | False | None | False | 3088.0 | 0 |
| 3622646 | 131618 | None | code52 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 9255.0 | 9255.0 | 1.0 | False | None | None | False | None | False | 9255.0 | 0 |
| 3622647 | 131618 | None | code53 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminium Strips | m | 3435.0 | 3435.0 | 1.0 | False | None | None | False | None | False | 3435.0 | 0 |
| 3622648 | 131618 | None | code54 | Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired | Each | 4390.0 | 4390.0 | 1.0 | False | None | None | False | None | False | 4390.0 | 0 |
| 3622649 | 131618 | None | code55 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. | Each | 690.0 | 690.0 | 8.0 | False | None | None | False | None | False | 5520.0 | 0 |
| 3622650 | 131618 | None | code56 | Supplying & Fixing of 70-150 W lamp holder 2 Pin | Nos | 63.0 | 63.0 | 8.0 | False | None | None | False | None | False | 504.0 | 0 |
| 3622651 | 131618 | None | code57 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 8.0 | False | None | None | False | None | False | 976.0 | 0 |
| 3622652 | 131618 | None | code58 | Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. | Each | 490.0 | 490.0 | 8.0 | False | None | None | False | None | False | 3920.0 | 0 |
| 3622653 | 131618 | None | code59 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model | Each | 2984.0 | 2984.0 | 4.0 | False | None | None | False | None | False | 11936.0 | 0 |
| 3622654 | 131618 | None | code60 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 315.0 | 315.0 | 4.0 | False | None | None | False | None | False | 1260.0 | 0 |