createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1721627782220
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2890.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose13-08-2024 17:00:00
tenderQueryClose09-08-2024 17:00:00
technicalBidOpen14-08-2024 17:15:00
publishedDate26-07-2024 17:18:02
publishedByPostCMC_MCOM_HYR
publishedByUserKPE12679 - H MAHANTESH
bidValidityPeriod90
noOfCalls1
preBidMeetingDate29-07-2024 10:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonAEE je
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber9738903974
mobileNumber8123006788
tenderSupplierListNone
tenderSchedule
createdTs1721627782255
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT19435
titleConstruction of Primary and secondary shed for 9TPD capacity material recovery facilities MRF Center in the area of solid waste disposal unit of hiriyur city
descriptionConstruction of Primary and secondary shed for 9TPD capacity material recovery facilities MRF Center in the area of solid waste disposal unit of hiriyur city CMC HIRIYUR LIMITS
categoryWORKS
categoryTextWorks
ecv11550000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2277
locationNameDMA City Municipal Council Hiriyur
provisionalAmount11550000.0
groupOverheadTotal1839769.51
fileNumberCMC/HYR/SBM20/MRF/01/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17216277820000NoneNoneBuildingsConstruction of Primary and secondary shed for 9TPD capacity material recovery facilities MRF Center in the area of solid waste disposal unit of hiriyur city9710230.49
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3573748129909Nonecode01KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum105.06105.06540.07FalseNoneNoneFalseNoneFalse56739.75420
3573749129909Nonecode02Providing and Filling in foundation with granite trap broken metal 100mm and down size with approved sand including hand packing ramming watering including cost of all materials and labor with all lead and lift complete as per specificationsCum2762.462762.4628.14FalseNoneNoneFalseNoneFalse77735.62440
3573750129909Nonecode03KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5833.925833.9290.01FalseNoneNoneFalseNoneFalse525111.13920
3573751129909Nonecode04KSRB 2232Providing and laying in position Reinforced cement concrete for all Foundation works The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers well compacted using needle vibrators including all lead lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications The cost of steel reinforcement formwork to be paid separately M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Specification No KBS 23 23 Item No 232 Page No 16 Vol1 PWD SR Appendix I page No111Addendum I Percentage Additionalities for Formwork Centering Scaffolding 1 Foundation upto Plinth a Isolated 8 percentCum7192.87192.824.16FalseNoneNoneFalseNoneFalse173778.0480
3573752129909Nonecode05KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding 9. RCC Columns / Shaft (Slip Centering) 70%Cum11210.411210.415.41FalseNoneNoneFalseNoneFalse172752.2640
3573753129909Nonecode06KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding 1. Foundation upto Plinth - a. Isolated 8%Cum7192.87192.8106.21FalseNoneNoneFalseNoneFalse763947.2880
3573754129909Nonecode07KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding 2. Plinth Beams of Buildings 50%Cum9694.089694.0810.71FalseNoneNoneFalseNoneFalse103823.59680
3573755129909Nonecode08Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings t 89457.00 (Item No. 2.11a Page No. 18 Vol.1 PWD SR)Tonne92140.7192140.7112.9327FalseNoneNoneFalseNoneFalse1191628.1602170
3573756129909Nonecode09KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6580.676580.6768.28FalseNoneNoneFalseNoneFalse449328.14760
3573757129909Nonecode10KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum488.22488.22756.01FalseNoneNoneFalseNoneFalse369099.20220
3573758129909Nonecode11Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. (Item No. 1.4.27 Page No. 24 Vol.3 PWD SR)Cum2635.772635.77106.42FalseNoneNoneFalseNoneFalse280498.64340
3573759129909Nonecode12KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Sqm1267.931267.93274.42FalseNoneNoneFalseNoneFalse347945.35060
3573760129909Nonecode13KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2)Sqm303.85303.85599.37FalseNoneNoneFalseNoneFalse182118.57450
3573761129909Nonecode14Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kgs116.39116.3927260.0FalseNoneNoneFalseNoneFalse3172791.40
3573762129909Nonecode15Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/ self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever equired. (Item No. 7.38, Page No. 26, Vol.2 PWD SR 2023-24)Sqm585.04585.041623.51FalseNoneNoneFalseNoneFalse949818.29040
3573763129909Nonecode16KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2)Sqm103.0103.0599.37FalseNoneNoneFalseNoneFalse61735.110
3573764129909Nonecode17KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)Sqm75.1975.19569.95FalseNoneNoneFalseNoneFalse42854.54050
3573765129909Nonecode18KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm2711.992711.9933.75FalseNoneNoneFalseNoneFalse91529.66250
3573766129909Nonecode19KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)No25426.5825426.582.0FalseNoneNoneFalseNoneFalse50853.160
3573767129909Nonecode20KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2)Kgs465.56465.56480.0FalseNoneNoneFalseNoneFalse223468.80
3573768129909Nonecode21Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS 1554 (Part 1) or IS 7098 Part 1, Armouring strip thickness and resistivity as per IS 3975Km240813.0240813.00.25FalseNoneNoneFalseNoneFalse60203.250
3573769129909Nonecode22Fabricating supplying and mounting MS box made out 14 SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.Sq CM0.50.578965.0FalseNoneNoneFalseNoneFalse39482.50
3573770129909Nonecode23Supplying heavy gauge PVC conduit pipe 32 mm dia 2.5 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thickMtr81.081.0500.0FalseNoneNoneFalseNoneFalse40500.00
3573771129909Nonecode24Supplying heavy gauge PVC conduit pipe 32 mm dia 2.5 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32 mm dia 2.5 mm thickMtr106.0106.0250.0FalseNoneNoneFalseNoneFalse26500.00
3573772129909Nonecode25Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 125 A 25 kAEach10341.010341.05.0FalseNoneNoneFalseNoneFalse51705.00
3573773129909Nonecode26Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 700 A 50 kAEach49900.049900.01.0FalseNoneNoneFalseNoneFalse49900.00
3573774129909Nonecode27Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.Each415.0415.03.0FalseNoneNoneFalseNoneFalse1245.00
3573775129909Nonecode28Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.Each562.0562.04.0FalseNoneNoneFalseNoneFalse2248.00
3573776129909Nonecode29Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., completeRmtr3435.03435.016.0FalseNoneNoneFalseNoneFalse54960.00
3573777129909Nonecode30Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cut outs and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit. The pits hould be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to bee stablished through GI wire of size as per lSI specification 7.3.3. of IS732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaNo3510.03510.06.0FalseNoneNoneFalseNoneFalse21060.00
3573778129909Nonecode31Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1 mm2Rmtr19.019.0400.0FalseNoneNoneFalseNoneFalse7600.00
3573779129909Nonecode32Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2Rmtr26.026.0600.0FalseNoneNoneFalseNoneFalse15600.00
3573780129909Nonecode33Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2Rmtr42.042.0400.0FalseNoneNoneFalseNoneFalse16800.00
3573781129909Nonecode34Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4.00 mm2Rmtr63.063.0250.0FalseNoneNoneFalseNoneFalse15750.00
3573782129909Nonecode35Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way SwitchEach102.0102.040.0FalseNoneNoneFalseNoneFalse4080.00
3573783129909Nonecode36Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way 5 Pin SocketEach70.070.08.0FalseNoneNoneFalseNoneFalse560.00
3573784129909Nonecode37Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal SocketEach236.0236.04.0FalseNoneNoneFalseNoneFalse944.00
3573785129909Nonecode38Supply of LED flood light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output Rated life Burning Hrs 50000hr @Lumen Maintenance of 70%, CCT 5500K, IP66 optical and electrical compartment & impactresistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection-Min 5KV along with Over voltage/OverloadEach6768.06768.02.0FalseNoneNoneFalseNoneFalse13536.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17216277840000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17216277840000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17216277840000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17216277840000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17216277840000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17216280020000NoneNoneELIGIBILITYEach bidder should have satisfactorily completed, at least one similar nature of work of value not less than the amount shown in the tender document in the last 5 years reckoned back from 2024-25. Work done certificate should be obtained from competent authority not below the rank of Executive EngineerNone
17216280140000NoneNoneELIGIBILITYConditional tenders will not be accepted. Tenderers are required to read the Bid Documents carefully before submission of their bidNone
17216280250000NoneNoneELIGIBILITYBefore submission of the tender, the contractor should see the work site. CMC Hiriyur is not responsible for technical or legal problems or queries from public accrued at the time of execution of workNone
17216280360000NoneNoneELIGIBILITYContractor should maintain up to 2 years after completion of work if any defects in the work found, if contractor fails FSD amount shall be forfeited and further action shall be takenNone
17216280460000NoneNoneELIGIBILITYContractors should be bound to conditions mentioned in tender document, circulars and orders given time to time by government and Royalty, Income tax, Sales tax, Labour cess shall be deducted according to government circulars in the work billNone
17216280570000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reason or what so everNone
17216280680000NoneNoneELIGIBILITYThe Tenderer shall scan Original Work done certificates / Turnover Statements and any other documents specified by the employer and attach the scanned file to the Bid. The Original Documents shall be produced for physical verification within one week from the date of Technical bid openingNone
17216280800000NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weightage of 10% per year to bring them to the price level of the 2024-25None
17216280920000NoneNoneELIGIBILITYAs per Karnataka State Government order No.LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No.PW/134/BMS/2007 Dated 27-07-2007, a sum amounting to 1%of the bill amount will be deducted towards Construction Labour Welfare fundNone
17216281020000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejectedNone
17216281120000NoneNoneELIGIBILITYThe work is subjected to the supervision of Junior Engineer, CMC, HIRIYUR, and Assistant Executive Engineer CMC HIRIYUR, Executive Engineer, District Urban Development Cell, Chitradurga, and Third Party appointed by the Deputy CommissionerNone
17216281240000NoneNoneELIGIBILITYThe earnest money deposit will be forfeited if the documents submitted by the tenderer found to be misleading/forged or fakeNone
17216281340000NoneNoneELIGIBILITYBidder has to quote rates exculding GST, GST shall be paid separatelyNone
17216281430000NoneNoneELIGIBILITYAll the Work done certificate uploaded should include E-procurement indent numberNone
17216281530000NoneNoneELIGIBILITYTurnover certificate from CA with valid UDIN No. to be furnished along with necessary documentsNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneSatisfactory completed, at least one similar development work of value not less than Rs.48.55 Lakhs as prime contractor(Work Done certificate with E-procurement Indent number and issued by the officer not below the rank of Executive Engineer or Equivalent)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe tenderer should have executed in any one year i.e., 2019-20 to 2023-24 (for a continuous period of 12 months) in last five years, the following minimum quantities of work Earth work excavation/embankment 1037.36Cum, PCC/RCC 197.20 Cum, TMT Steel 10.30 Tonne, MS Structural steel 21808 Kg, SSM/Solid Block 98.53 Cum, , Galvanized Sheet/Ac Sheet 1298.80 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe Tender should be a KPWD Registered Class-III and Above Contractor (Attach Registration Certificate)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneTo qualify for Award of this contract, each Tenderer in his name should have in the last five years i.e. 2019-20 to 2023-24, achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs.194.20 Lakhs certified by chartered accountant with valid UDIN No.to be furnished along with necessary documents)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and or availability of credit facilities of not less than Rs.29.13 lakhs (Unconditional Credit lines/Letters of Credit / Certificates from any Nationalized and scheduled Banks) for meeting the fund requirement etcFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNonePAN CARD and GST REGISTRATION CERTIFICATEFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneNOT APPLICABLEOthersOTHERS
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersothers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersothers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersothers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersothers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersothers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersothers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersothers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersothers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersothers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual turnover certificate Achieved in at least two financial years a minimum annual financial turnover of Rs.194.20 LakhsTrueTechnical Bid
Work done certificate Satisfactory completed, at least one similar development work of value not less than Rs.48.55 Lakhs as prime contractorTrueTechnical Bid
PWD CONTRACTOR LICENCE REGISTRATION CERTIFICATE CLASS 3 AND ABOVETrueTechnical Bid
PAN CARD and GST REGISTRATION CERTIFICATETrueTechnical Bid
The tenderer should have executed in any one year i.e. 2019-20 to 2023-24 for a continuous period of 12 months in last five years, the following minimum quantities of work Earth work excavation/embnkment 1037.36Cum, PCC/RCC 197.20 Cum, TMT Steel 10.30 Tonne, MS Structural steel 21808 Kg, SSM/Solid Block 98.53 Cum, , Galvanized Sheet/Ac Sheet 1298.80 SqmTrueTechnical Bid
Line of credit Liquid assets and or availability of credit facilities of not less than Rs.29.13 lakhs Unconditional Credit lines/Letters of Credit / Certificates from any Nationalized and scheduled Banks for meeting the fund requirement etc.TrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1721823359000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of Muncipal Commissioner.City Muncipal Council Hiriyur.MAIN ROAD HIRIYUR
streetNone
cityHiriyur
stateKarnataka
pin577598
tenderRecallDTONone