| 1721627782000 | 0 | None | None | Buildings | Construction of Primary and secondary shed for 9TPD capacity material recovery facilities MRF Center in the area of solid waste disposal unit of hiriyur city | 9710230.49 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3573748 | 129909 | None | code01 | KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR) | Cum | 105.06 | 105.06 | 540.07 | False | None | None | False | None | False | 56739.7542 | 0 | | 3573749 | 129909 | None | code02 | Providing and Filling in foundation with granite trap broken metal 100mm and down size with approved sand including hand packing ramming watering including cost of all materials and labor with all lead and lift complete as per specifications | Cum | 2762.46 | 2762.46 | 28.14 | False | None | None | False | None | False | 77735.6244 | 0 | | 3573750 | 129909 | None | code03 | KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR) | Cum | 5833.92 | 5833.92 | 90.01 | False | None | None | False | None | False | 525111.1392 | 0 | | 3573751 | 129909 | None | code04 | KSRB 2232Providing and laying in position Reinforced cement concrete for all Foundation works The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers well compacted using needle vibrators including all lead lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications The cost of steel reinforcement formwork to be paid separately M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Specification No KBS 23 23 Item No 232 Page No 16 Vol1 PWD SR Appendix I page No111Addendum I Percentage Additionalities for Formwork Centering Scaffolding 1 Foundation upto Plinth
a Isolated 8 percent | Cum | 7192.8 | 7192.8 | 24.16 | False | None | None | False | None | False | 173778.048 | 0 | | 3573752 | 129909 | None | code05 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding 9. RCC Columns / Shaft (Slip Centering) 70% | Cum | 11210.4 | 11210.4 | 15.41 | False | None | None | False | None | False | 172752.264 | 0 | | 3573753 | 129909 | None | code06 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding 1. Foundation upto Plinth -
a. Isolated 8% | Cum | 7192.8 | 7192.8 | 106.21 | False | None | None | False | None | False | 763947.288 | 0 | | 3573754 | 129909 | None | code07 | KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.111)Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding 2. Plinth Beams of Buildings 50% | Cum | 9694.08 | 9694.08 | 10.71 | False | None | None | False | None | False | 103823.5968 | 0 | | 3573755 | 129909 | None | code08 | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings t 89457.00 (Item No. 2.11a Page No. 18 Vol.1 PWD SR) | Tonne | 92140.71 | 92140.71 | 12.9327 | False | None | None | False | None | False | 1191628.160217 | 0 | | 3573756 | 129909 | None | code09 | KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR) | Cum | 6580.67 | 6580.67 | 68.28 | False | None | None | False | None | False | 449328.1476 | 0 | | 3573757 | 129909 | None | code10 | KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR) | Cum | 488.22 | 488.22 | 756.01 | False | None | None | False | None | False | 369099.2022 | 0 | | 3573758 | 129909 | None | code11 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. (Item No. 1.4.27 Page No. 24 Vol.3 PWD SR) | Cum | 2635.77 | 2635.77 | 106.42 | False | None | None | False | None | False | 280498.6434 | 0 | | 3573759 | 129909 | None | code12 | KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR) | Sqm | 1267.93 | 1267.93 | 274.42 | False | None | None | False | None | False | 347945.3506 | 0 | | 3573760 | 129909 | None | code13 | KSRB 8-8.3.1: Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2) | Sqm | 303.85 | 303.85 | 599.37 | False | None | None | False | None | False | 182118.5745 | 0 | | 3573761 | 129909 | None | code14 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2) | Kgs | 116.39 | 116.39 | 27260.0 | False | None | None | False | None | False | 3172791.4 | 0 | | 3573762 | 129909 | None | code15 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/ self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever equired. (Item No. 7.38, Page No. 26, Vol.2 PWD SR 2023-24) | Sqm | 585.04 | 585.04 | 1623.51 | False | None | None | False | None | False | 949818.2904 | 0 | | 3573763 | 129909 | None | code16 | KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2) | Sqm | 103.0 | 103.0 | 599.37 | False | None | None | False | None | False | 61735.11 | 0 | | 3573764 | 129909 | None | code17 | KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2) | Sqm | 75.19 | 75.19 | 569.95 | False | None | None | False | None | False | 42854.5405 | 0 | | 3573765 | 129909 | None | code18 | KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2) | Sqm | 2711.99 | 2711.99 | 33.75 | False | None | None | False | None | False | 91529.6625 | 0 | | 3573766 | 129909 | None | code19 | KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2) | No | 25426.58 | 25426.58 | 2.0 | False | None | None | False | None | False | 50853.16 | 0 | | 3573767 | 129909 | None | code20 | KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2) | Kgs | 465.56 | 465.56 | 480.0 | False | None | None | False | None | False | 223468.8 | 0 | | 3573768 | 129909 | None | code21 | Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS 1554 (Part 1) or IS 7098 Part 1, Armouring strip thickness and resistivity as per IS 3975 | Km | 240813.0 | 240813.0 | 0.25 | False | None | None | False | None | False | 60203.25 | 0 | | 3573769 | 129909 | None | code22 | Fabricating supplying and mounting MS box made out 14 SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. | Sq CM | 0.5 | 0.5 | 78965.0 | False | None | None | False | None | False | 39482.5 | 0 | | 3573770 | 129909 | None | code23 | Supplying heavy gauge PVC conduit pipe 32 mm dia 2.5 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick | Mtr | 81.0 | 81.0 | 500.0 | False | None | None | False | None | False | 40500.0 | 0 | | 3573771 | 129909 | None | code24 | Supplying heavy gauge PVC conduit pipe 32 mm dia 2.5 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32 mm dia 2.5 mm thick | Mtr | 106.0 | 106.0 | 250.0 | False | None | None | False | None | False | 26500.0 | 0 | | 3573772 | 129909 | None | code25 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 125 A 25 kA | Each | 10341.0 | 10341.0 | 5.0 | False | None | None | False | None | False | 51705.0 | 0 | | 3573773 | 129909 | None | code26 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 700 A 50 kA | Each | 49900.0 | 49900.0 | 1.0 | False | None | None | False | None | False | 49900.0 | 0 | | 3573774 | 129909 | None | code27 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. | Each | 415.0 | 415.0 | 3.0 | False | None | None | False | None | False | 1245.0 | 0 | | 3573775 | 129909 | None | code28 | Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. | Each | 562.0 | 562.0 | 4.0 | False | None | None | False | None | False | 2248.0 | 0 | | 3573776 | 129909 | None | code29 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete | Rmtr | 3435.0 | 3435.0 | 16.0 | False | None | None | False | None | False | 54960.0 | 0 | | 3573777 | 129909 | None | code30 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cut outs and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit. The pits hould be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to bee stablished through GI wire of size as per lSI specification 7.3.3. of IS732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | No | 3510.0 | 3510.0 | 6.0 | False | None | None | False | None | False | 21060.0 | 0 | | 3573778 | 129909 | None | code31 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1 mm2 | Rmtr | 19.0 | 19.0 | 400.0 | False | None | None | False | None | False | 7600.0 | 0 | | 3573779 | 129909 | None | code32 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | Rmtr | 26.0 | 26.0 | 600.0 | False | None | None | False | None | False | 15600.0 | 0 | | 3573780 | 129909 | None | code33 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | Rmtr | 42.0 | 42.0 | 400.0 | False | None | None | False | None | False | 16800.0 | 0 | | 3573781 | 129909 | None | code34 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4.00 mm2 | Rmtr | 63.0 | 63.0 | 250.0 | False | None | None | False | None | False | 15750.0 | 0 | | 3573782 | 129909 | None | code35 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 102.0 | 102.0 | 40.0 | False | None | None | False | None | False | 4080.0 | 0 | | 3573783 | 129909 | None | code36 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way 5 Pin Socket | Each | 70.0 | 70.0 | 8.0 | False | None | None | False | None | False | 560.0 | 0 | | 3573784 | 129909 | None | code37 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket | Each | 236.0 | 236.0 | 4.0 | False | None | None | False | None | False | 944.0 | 0 | | 3573785 | 129909 | None | code38 | Supply of LED flood light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output Rated life Burning Hrs 50000hr @Lumen Maintenance of 70%, CCT 5500K, IP66 optical and electrical compartment & impactresistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection-Min 5KV along with Over voltage/Overload | Each | 6768.0 | 6768.0 | 2.0 | False | None | None | False | None | False | 13536.0 | 0 |
|