tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1721369397000 | 0 | None | None | Buildings | Cutting and Levelling the area | 6257570.09 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546702 | 128169 | None | Item Code2.5(ii)a VOL 3 Page No9 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness By Mechanical Means using Dozer In area of light jungle
---- Work should be carried out as per the direction of engineer incharge of work. | 100 Sqm | 463.74 | 463.74 | 50.4 | False | None | None | False | None | False | 23372.496 | 0 | 3546703 | 128169 | None | Item Code1.14.1VOL Page No8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 120.36 | 120.36 | 3532.5 | False | None | None | False | None | False | 425171.7 | 0 | 3546704 | 128169 | None | Item Code1.15.2 VOL1 Page No9 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting depth exceeding 1.5m , but not exceeding 3m
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 501.5 | 501.5 | 392.5 | False | None | None | False | None | False | 196838.75 | 0 | 3546705 | 128169 | None | Item Code1.14.2 VOL1 Page No8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth 3 m to 6 m
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 138.06 | 138.06 | 16611.75 | False | None | None | False | None | False | 2293418.205 | 0 | 3546706 | 128169 | None | Item Code1.15.3VOL1 Page No9 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting Depth exceeding 3m, but not exceeding 4.5m Note: 3. Add 5% per m3 for every additional 1.50m depth or part thereoff beyond 4.50 m depth is provided
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 573.66 | 573.66 | 1845.75 | False | None | None | False | None | False | 1058832.945 | 0 | 3546707 | 128169 | None | Item Code1.9VOL1Page No7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 313.88 | 313.88 | 7200.0 | False | None | None | False | None | False | 2259936.0 | 0 |
| 1721369397000 | 0 | None | None | Buildings | Retaining wall | 16735206.43 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546708 | 128170 | None | Item Code1.14.1VOL1Page No8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including Cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m (Vol 1, Page No: 8, Item No: 1.14.1)
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 120.36 | 120.36 | 872.15 | False | None | None | False | None | False | 104971.974 | 0 | 3546709 | 128170 | None | Item Code1.15.2VOL1Page No9 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting depth exceeding 1.5m , but not exceeding 3m(Vol 1, Page No: 9, Item No: 1.15.2)
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 501.5 | 501.5 | 96.91 | False | None | None | False | None | False | 48600.365 | 0 | 3546710 | 128170 | None | Item Code2.1.4VOL1Page No15 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, andall the other appurtenances required to complete the work as per technical specifications. .Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates (Vol 1, Page No: 15, Item No: 2.1.4)
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7336.06 | 7336.06 | 105.9 | False | None | None | False | None | False | 776888.754 | 0 | 3546711 | 128170 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. (Vol 1, Page No: 18, Item No: 2.10 C)
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 965.79 | False | None | None | False | None | False | 7087372.6518 | 0 | 3546712 | 128170 | None | Item Code12.2VOL3Page No117 | Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with PVC Pipe 110mm outer dia at 2 kg per m2 ,extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications (Vol 3, Page No: 117, Item No: 12.2)
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 282.02 | 282.02 | 217.0 | False | None | None | False | None | False | 61198.34 | 0 | 3546713 | 128170 | None | Item Code12.4VOL3Page No117 | Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification. (Vol 3, Page No: 117, Item No: 12.4)
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3158.86 | 3158.86 | 573.06 | False | None | None | False | None | False | 1810216.3116 | 0 | 3546714 | 128170 | None | Item Code2.11aVOL1Page No18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Vol 1, Page No: 18, Item No: 2.11a)
Wall
---- Work should be carried out as per the direction of engineer incharge of work. | t | 105559.26 | 105559.26 | 58.14 | False | None | None | False | None | False | 6137215.3764 | 0 | 3546715 | 128170 | None | SINo11 VOL1Page No112 | Formwork, Centering & Scaffloding 10% For Earth retaining structures
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 733.84 | 733.84 | 965.8 | False | None | None | False | None | False | 708742.672 | 0 |
| 1721369397000 | 0 | None | None | Buildings | Ground Floor | 28910663.69 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546716 | 128171 | None | Item Code1.14.1VOL1Page No8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 120.36 | 120.36 | 826.13 | False | None | None | False | None | False | 99433.0068 | 0 | 3546717 | 128171 | None | Item Code1.15.2VOL1Page No9 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting depth exceeding 1.5m , but not exceeding 3m
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 501.5 | 501.5 | 91.79 | False | None | None | False | None | False | 46032.685 | 0 | 3546718 | 128171 | None | Item Code4.1VOL2Page No5 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, ground excavation top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 ltr/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 139.24 | 139.24 | 1126.83 | False | None | None | False | None | False | 156899.8092 | 0 | 3546719 | 128171 | None | Item Code1.9VOL1Page No7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 313.88 | 313.88 | 826.13 | False | None | None | False | None | False | 259305.6844 | 0 | 3546720 | 128171 | None | Item Code1.11VOL1Page No7 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 510.94 | 510.94 | 818.9 | False | None | None | False | None | False | 418408.766 | 0 | 3546721 | 128171 | None | Item Code2.1.3VOL1Page No15 | Providing and laying in position plain Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour,Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7067.02 | 7067.02 | 226.63 | False | None | None | False | None | False | 1601598.7426 | 0 | 3546722 | 128171 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Isolated Footing
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 215.41 | False | None | None | False | None | False | 1580769.0522 | 0 | 3546723 | 128171 | None | SINo1aVOL1Page No111 | Formwork, Centering & Scaffloding 8% For Isolated Footing
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 587.07 | 587.07 | 215.41 | False | None | None | False | None | False | 126460.7487 | 0 | 3546724 | 128171 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Combined Footing
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 32.96 | False | None | None | False | None | False | 241874.3232 | 0 | 3546725 | 128171 | None | SINo1bVOL1Page No111 | Formwork, Centering & Scaffloding 3% For Combined Footing
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 220.15 | 220.15 | 32.96 | False | None | None | False | None | False | 7256.144 | 0 | 3546726 | 128171 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Pedestal
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 10.47 | False | None | None | False | None | False | 76833.2574 | 0 | 3546727 | 128171 | None | SINo1aVOL1Page No111 | Formwork, Centering & Scaffloding 8% For Pedestal
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 587.07 | 587.07 | 10.47 | False | None | None | False | None | False | 6146.6229 | 0 | 3546728 | 128171 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Colums upto plinth
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 15.47 | False | None | None | False | None | False | 113525.3574 | 0 | 3546729 | 128171 | None | SINo9VOL1Page No111 | Formwork, Centering & Scaffloding 70% For Columns upto plinth
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 5136.89 | 5136.89 | 15.47 | False | None | None | False | None | False | 79467.6883 | 0 | 3546730 | 128171 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Columns
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 46.66 | False | None | None | False | None | False | 342410.6772 | 0 | 3546731 | 128171 | None | SL9VOL1Page No111 | Formwork, Centering & Scaffloding 70% For Columns
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 5136.89 | 5136.89 | 46.66 | False | None | None | False | None | False | 239687.2874 | 0 | 3546732 | 128171 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade.Plinth beams
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 56.79 | False | None | None | False | None | False | 416748.8718 | 0 | 3546733 | 128171 | None | SINo2VOL1Page No111 | Formwork, Centering & Scaffloding 50% For Plinth Beams
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3669.21 | 3669.21 | 56.79 | False | None | None | False | None | False | 208374.4359 | 0 | 3546734 | 128171 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade.Curtain wall
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 28.44 | False | None | None | False | None | False | 208704.6648 | 0 | 3546735 | 128171 | None | SL 11VOL1Page No112 | Formwork, Centering & Scaffloding 10% For Curtain wall
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 733.84 | 733.84 | 28.44 | False | None | None | False | None | False | 20870.4096 | 0 | 3546736 | 128171 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Beams
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 75.32 | False | None | None | False | None | False | 552729.7944 | 0 | 3546737 | 128171 | None | SL 14VOL1Page No112 | Formwork, Centering & Scaffloding 60% For Beams
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 4403.05 | 4403.05 | 75.32 | False | None | None | False | None | False | 331637.726 | 0 | 3546738 | 128171 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade.Slab & Staircase
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 148.78 | False | None | None | False | None | False | 1091810.1276 | 0 | 3546739 | 128171 | None | SL 16VOL1Page No112 | Formwork, Centering & Scaffloding 50% For Roof Slab & Staircase
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3669.21 | 3669.21 | 148.78 | False | None | None | False | None | False | 545905.0638 | 0 | 3546740 | 128171 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Sill & Lintel
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 26.15 | False | None | None | False | None | False | 191899.683 | 0 | 3546741 | 128171 | None | SL 14VOL1Page No112 | Formwork, Centering & Scaffloding 60% For Sill & Lintel
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 4403.05 | 4403.05 | 26.15 | False | None | None | False | None | False | 115139.7575 | 0 | 3546742 | 128171 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Chejja
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 14.6 | False | None | None | False | None | False | 107140.932 | 0 | 3546743 | 128171 | None | SL 19VOL1Page No112 | Formwork, Centering & Scaffloding 45% For Chejja
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3302.29 | 3302.29 | 14.6 | False | None | None | False | None | False | 48213.434 | 0 | 3546744 | 128171 | None | Item Code2.11AVOL1Page No18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
---- Work should be carried out as per the direction of engineer incharge of work. | Tonne | 105559.26 | 105559.26 | 61.1 | False | None | None | False | None | False | 6449670.786 | 0 | 3546745 | 128171 | None | Item Code5.4VOL2Page No9 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7539.02 | 7539.02 | 28.19 | False | None | None | False | None | False | 212524.9738 | 0 | 3546746 | 128171 | None | Item Code6.8VOL2Page No14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 9403.42 | 9403.42 | 315.31 | False | None | None | False | None | False | 2964992.3602 | 0 | 3546747 | 128171 | None | Item Code6.15VOL2Page No14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 1218.94 | 1218.94 | 106.24 | False | None | None | False | None | False | 129500.1856 | 0 | 3546748 | 128171 | None | Item Code12.13.1VOL2Page No100 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 116601.7 | 116601.7 | 4.48 | False | None | None | False | None | False | 522375.616 | 0 | 3546749 | 128171 | None | Item Code12.51VOL2Page No104 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 1198.88 | 1198.88 | 35.0 | False | None | None | False | None | False | 41960.8 | 0 | 3546750 | 128171 | None | Item Code10.6.3VOL2Page No69 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 70.8 | 70.8 | 210.0 | False | None | None | False | None | False | 14868.0 | 0 | 3546751 | 128171 | None | Item Code12.15VOL2Page No100 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 8783.92 | 8783.92 | 103.91 | False | None | None | False | None | False | 912737.1272 | 0 | 3546752 | 128171 | None | Item Code12.88VOL2Page No110 | Providing & fixing of 2-track x 2-panel sliding door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour havingisolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm (The cost is inclusive of all fixtures and separate charges for minor T shall not be made)
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 6360.2 | 6360.2 | 3.78 | False | None | None | False | None | False | 24041.556 | 0 | 3546753 | 128171 | None | Item Code12.90VOL2Page No110 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 7946.12 | 7946.12 | 133.6 | False | None | None | False | None | False | 1061601.632 | 0 | 3546754 | 128171 | None | Item Code12.85VOL2Page No109 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 6748.42 | 6748.42 | 27.45 | False | None | None | False | None | False | 185244.129 | 0 | 3546755 | 128171 | None | Item Code11.34BVOL2Page No86 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
---- Work should be carried out as per the direction of engineer incharge of work. | Kg | 215.94 | 215.94 | 3603.65 | False | None | None | False | None | False | 778172.181 | 0 | 3546756 | 128171 | None | Item Code8.1.2VOL2Page No41 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 284.38 | 284.38 | 2381.36 | False | None | None | False | None | False | 677211.1568 | 0 | 3546757 | 128171 | None | Item Code8.51VOL2Page No50 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 118.0 | 118.0 | 3902.96 | False | None | None | False | None | False | 460549.28 | 0 | 3546758 | 128171 | None | Item Code8.2.2VOL2Page No41 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Out side)
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 329.22 | 329.22 | 755.97 | False | None | None | False | None | False | 248880.4434 | 0 | 3546759 | 128171 | None | Item Code9.17.2VOL2Page No61 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.(Size of Tile 600x600 mm)
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 1386.5 | 1386.5 | 537.07 | False | None | None | False | None | False | 744647.555 | 0 | 3546760 | 128171 | None | Item Code9.2VOL2Page No59 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 944.0 | 944.0 | 174.6 | False | None | None | False | None | False | 164822.4 | 0 | 3546761 | 128171 | None | Item Code9.24VOL2Page No63 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 14 (1 cement 4 coarse sand) laid and jointed with cement slurry and pointing with whitecement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 3365.36 | 3365.36 | 496.73 | False | None | None | False | None | False | 1671675.2728 | 0 | 3546762 | 128171 | None | Item Code9.11VOL2Page No60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 1049.02 | 1049.02 | 59.18 | False | None | None | False | None | False | 62081.0036 | 0 | 3546763 | 128171 | None | Item Code10.14VOL2Page No71 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching
shade complete."
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 1305.08 | 1305.08 | 184.96 | False | None | None | False | None | False | 241387.5968 | 0 | 3546764 | 128171 | None | Item Code10.1.2VOL2Page No69 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 4645.66 | 4645.66 | 7.2 | False | None | None | False | None | False | 33448.752 | 0 | 3546765 | 128171 | None | Item Code11.28VOL2Page No85 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessoris such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 666.7 | 666.7 | 1700.37 | False | None | None | False | None | False | 1133636.679 | 0 | 3546766 | 128171 | None | Item Code8.33.1VOL2Page No46 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 186.44 | 186.44 | 3902.96 | False | None | None | False | None | False | 727667.8624 | 0 | 3546767 | 128171 | None | Item Code8.3VOL2Page No46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paer smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 205.32 | 205.32 | 755.97 | False | None | None | False | None | False | 155215.7604 | 0 | 3546768 | 128171 | None | Item Code8.33.3VOL2Page No47 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 164.02 | 164.02 | 171.6 | False | None | None | False | None | False | 28145.832 | 0 | 3546769 | 128171 | None | Item Code8.54VOL3Page No78 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge & MoRTH specification 804
---- Work should be carried out as per the direction of engineer incharge of work. | No | 10620.0 | 10620.0 | 2.0 | False | None | None | False | None | False | 21240.0 | 0 | 3546770 | 128171 | None | Item Code8.49VOL2Page No49 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Per cm Height Per Letter | 4.72 | 4.72 | 1500.0 | False | None | None | False | None | False | 7080.0 | 0 |
| 1721369397000 | 0 | None | None | Buildings | Terrace Floor (including waterproofing & parapet wall) | 3129507.24 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546771 | 128172 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Columns
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7411.8 | 7411.8 | 15.99 | False | None | None | False | None | False | 118514.682 | 0 | 3546772 | 128172 | None | SINo9VOL1Page No111 | Formwork, Centering & Scaffloding 70% For Columns
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 5188.26 | 5188.26 | 15.99 | False | None | None | False | None | False | 82960.2774 | 0 | 3546773 | 128172 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade.Sill & Lintel
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7411.8 | 7411.8 | 2.41 | False | None | None | False | None | False | 17862.438 | 0 | 3546774 | 128172 | None | SINo14VOL1Page No112 | Formwork, Centering & Scaffloding 60% For Sill & Lintel
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 4447.08 | 4447.08 | 2.41 | False | None | None | False | None | False | 10717.4628 | 0 | 3546775 | 128172 | None | Item Code2.11AVOL1Page No18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 106614.85 | 106614.85 | 3.44 | False | None | None | False | None | False | 366755.084 | 0 | 3546776 | 128172 | None | Item Code6.8VOL2Page No14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 9497.45 | 9497.45 | 46.55 | False | None | None | False | None | False | 442106.2975 | 0 | 3546777 | 128172 | None | Item Code6.15VOL2Page No14 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 1231.13 | 1231.13 | 172.23 | False | None | None | False | None | False | 212037.5199 | 0 | 3546778 | 128172 | None | Item Code12.90VOL2Page No110 | Providing fixing of 3track 2panel sliding windows made out of multi chambered UPVCMatching to RAL9016sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm 75mm with GI reinforcement of 2mm and mesh sash of size 37mm 58mm. Coextruded Glazing bead for fixing of glass shall be of size20mm 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware Multi point locking system with touch lock. Wall thickness of frame sash shall be of 2mm2.5mm. Maximum possible size 2419mm 2200mm. The cost is inclusive of all fixtures and separate charges for minor TPs shall not be made
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 8025.58 | 8025.58 | 8.1 | False | None | None | False | None | False | 65007.198 | 0 | 3546779 | 128172 | None | Item Code11.34BVOL2Page No86 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
---- Work should be carried out as per the direction of engineer incharge of work. | Kg | 218.1 | 218.1 | 170.1 | False | None | None | False | None | False | 37098.81 | 0 | 3546780 | 128172 | None | Item Code11.5.2VOL2Page No75 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 5055.62 | 5055.62 | 6.62 | False | None | None | False | None | False | 33468.2044 | 0 | 3546781 | 128172 | None | Item Code8.1.2VOL2Page No41 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 287.22 | 287.22 | 179.42 | False | None | None | False | None | False | 51533.0124 | 0 | 3546782 | 128172 | None | Item Code8.51VOL2Page No50 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 119.18 | 119.18 | 179.66 | False | None | None | False | None | False | 21411.8788 | 0 | 3546783 | 128172 | None | Item Code8.2.2VOL2Page No41 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Out side)
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 332.51 | 332.51 | 599.81 | False | None | None | False | None | False | 199442.8231 | 0 | 3546784 | 128172 | None | Item Code15.1VOL2Page No149 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product &work from certified manufacturers as per the direction of the Engineer In charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 973.7 | 973.7 | 1156.85 | False | None | None | False | None | False | 1126424.845 | 0 | 3546785 | 128172 | None | Item Code8.33.1VOL2Page No46 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 188.3 | 188.3 | 179.66 | False | None | None | False | None | False | 33829.978 | 0 | 3546786 | 128172 | None | Item Code8.3VOL2Page No46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paer smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 207.37 | 207.37 | 599.77 | False | None | None | False | None | False | 124374.3049 | 0 | 3546787 | 128172 | None | Item Code8.33.3VOL2Page No46 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 165.66 | 165.66 | 14.72 | False | None | None | False | None | False | 2438.5152 | 0 | 3546788 | 128172 | None | Item Code11.16.1VOL2Page No82 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 162.08 | 162.08 | 688.0 | False | None | None | False | None | False | 111511.04 | 0 | 3546789 | 128172 | None | Item Code7.38VOL2Page No26 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 676.94 | 676.94 | 106.38 | False | None | None | False | None | False | 72012.8772 | 0 |
| 1721369397000 | 0 | None | None | Buildings | Door Fixtures | 136876.46 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546790 | 128173 | None | Vol 2Item Code22.15.2 Pg No218 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS Handles 300mm (Pg.no 218 It.no 22.15.2)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 649.0 | 649.0 | 58.0 | False | None | None | False | None | False | 37642.0 | 0 | 3546791 | 128173 | None | Vol 2Item Code22.15.2Pg No218 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS Handles 300mm (Pg.no 218 It.no 22.15.2)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 649.0 | 649.0 | 20.0 | False | None | None | False | None | False | 12980.0 | 0 | 3546792 | 128173 | None | Vol 2Item Code22.15.4Pg No219 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS Aldrop 16mm dia, 300mm (Pg.no 219 It.no 22.15.4)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 442.5 | 442.5 | 29.0 | False | None | None | False | None | False | 12832.5 | 0 | 3546793 | 128173 | None | Vol 2Item Code22.15.4Pg No219 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS Aldrop 16mm dia, 300mm (Pg.no 219 It.no 22.15.4)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 442.5 | 442.5 | 10.0 | False | None | None | False | None | False | 4425.0 | 0 | 3546794 | 128173 | None | Vol 2Item Code22.15.5Pg No219 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS Tower Bolts 150x10mm (Pg.no 219 It.no 22.15.5)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 141.6 | 141.6 | 29.0 | False | None | None | False | None | False | 4106.4 | 0 | 3546795 | 128173 | None | Vol 2Item Code22.15.5Pg No219 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS Tower Bolts 150x10mm (Pg.no 219 It.no 22.15.5)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 141.6 | 141.6 | 10.0 | False | None | None | False | None | False | 1416.0 | 0 | 3546796 | 128173 | None | Vol 2Item Code22.15.7Pg No219 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS Tower Bolts 250x10mm (Pg.no 219 It.no 22.15.7)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 236.0 | 236.0 | 29.0 | False | None | None | False | None | False | 6844.0 | 0 | 3546797 | 128173 | None | Vol 2Item Code22.15.7Pg No219 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS Tower Bolts 250x10mm (Pg.no 219 It.no 22.15.7)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 236.0 | 236.0 | 10.0 | False | None | None | False | None | False | 2360.0 | 0 | 3546798 | 128173 | None | Vol 2Item Code22.15.9Pg No219 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS hinges 100 mm (Pg.no 219 It.no 22.15.9)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 82.6 | 82.6 | 145.0 | False | None | None | False | None | False | 11977.0 | 0 | 3546799 | 128173 | None | Vol 2Item Code22.15.9Pg No219 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS hinges 100 mm (Pg.no 219 It.no 22.15.9)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 82.6 | 82.6 | 50.0 | False | None | None | False | None | False | 4130.0 | 0 | 3546800 | 128173 | None | Vol 2Item Code22.15.10Pg No219 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS Door stopper 75mm (Pg.no 219 It.no 22.15.10)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 118.0 | 118.0 | 29.0 | False | None | None | False | None | False | 3422.0 | 0 | 3546801 | 128173 | None | Vol 2Item Code22.15.10Pg No219 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS Door stopper 75mm (Pg.no 219 It.no 22.15.10)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 118.0 | 118.0 | 10.0 | False | None | None | False | None | False | 1180.0 | 0 | 3546802 | 128173 | None | Vol 2Item Code12.60Pg No105 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (Pg.no 105 It.no 12.60)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 1241.36 | 1241.36 | 3.0 | False | None | None | False | None | False | 3724.08 | 0 | 3546803 | 128173 | None | Vol 2Item Code12.80.1Pg No108 | Providing and fixing door latch with necessary screws etc complete. Bright finished brass latch (Pg.no 108 It.no 12.80.1)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 336.3 | 336.3 | 29.0 | False | None | None | False | None | False | 9752.7 | 0 | 3546804 | 128173 | None | Vol 2Item Code12.80.1Pg No108 | Providing and fixing door latch with necessary screws etc complete. Bright finished brass latch (Pg.no 108 It.no 12.80.1)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 336.3 | 336.3 | 5.0 | False | None | None | False | None | False | 1681.5 | 0 | 3546805 | 128173 | None | Vol 2Item Code12.59Pg No105 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.(Pg.no 105 It.no 12.59)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 1314.52 | 1314.52 | 14.0 | False | None | None | False | None | False | 18403.28 | 0 |
| 1721369397000 | 0 | None | None | Buildings | Water supply & Sanitation | 2938565.8 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546806 | 128174 | None | Item Code13.2.1VOL2Page No117 | Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 1318.06 | 1318.06 | 74.0 | False | None | None | False | None | False | 97536.44 | 0 | 3546807 | 128174 | None | Item Code13.20.2VOL2Page No120 | Providing and fixing Pillar Cock made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class economy ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 1443.14 | 1443.14 | 18.0 | False | None | None | False | None | False | 25976.52 | 0 | 3546808 | 128174 | None | Item Code14.1.1VOL2Page No131 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 5763.12 | 5763.12 | 4.0 | False | None | None | False | None | False | 23052.48 | 0 | 3546809 | 128174 | None | Item Code14.2.1VOL2Page No131 | Providing and fixing white vitreous china pedestal type water closet (European pan with seat and lid 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever conforming to 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required pan with ISI marked white solid plastic seat and lid ---- Work should be carried out as per the direction of engineer incharge of work. | Each | 5708.84 | 5708.84 | 10.0 | False | None | None | False | None | False | 57088.4 | 0 | 3546810 | 128174 | None | Item Code14.7.8VOL2Page No133 | White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 4853.34 | 4853.34 | 18.0 | False | None | None | False | None | False | 87360.12 | 0 | 3546811 | 128174 | None | Item Code14.8VOL2Page No133 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 1679.14 | 1679.14 | 18.0 | False | None | None | False | None | False | 30224.52 | 0 | 3546812 | 128174 | None | Item Code14.4.2VOL2Page No131 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 8005.12 | 8005.12 | 10.0 | False | None | None | False | None | False | 80051.2 | 0 | 3546813 | 128174 | None | Item Code14.40.2VOL2Page No137 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 585.28 | 585.28 | 45.0 | False | None | None | False | None | False | 26337.6 | 0 | 3546814 | 128174 | None | Item Code14.32.2VOL2Page No136 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 1201.24 | 1201.24 | 45.0 | False | None | None | False | None | False | 54055.8 | 0 | 3546815 | 128174 | None | Item Code13.31.2VOL2Page No122 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 20mm nominal dia pipes
---- Work should be carried out as per the direction of engineer incharge of work. | Rmtr | 285.56 | 285.56 | 150.0 | False | None | None | False | None | False | 42834.0 | 0 | 3546816 | 128174 | None | Item Code13.31.3VOL2Page No122 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 25mm nominal dia pipes
---- Work should be carried out as per the direction of engineer incharge of work. | Rmtr | 375.24 | 375.24 | 150.0 | False | None | None | False | None | False | 56286.0 | 0 | 3546817 | 128174 | None | Item Code13.31.4VOL2Page No122 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 32mm nominal dia pipes
---- Work should be carried out as per the direction of engineer incharge of work. | Rmtr | 472.0 | 472.0 | 150.0 | False | None | None | False | None | False | 70800.0 | 0 | 3546818 | 128174 | None | Item Code13.31.6VOL2Page No122 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.Exposed on wall - 50mm nominal dia pipes
---- Work should be carried out as per the direction of engineer incharge of work. | Rmtr | 921.58 | 921.58 | 450.0 | False | None | None | False | None | False | 414711.0 | 0 | 3546819 | 128174 | None | Item Code13.4.4VOL2Page No117 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 1008.9 | 1008.9 | 90.0 | False | None | None | False | None | False | 90801.0 | 0 | 3546820 | 128174 | None | Item Code13.8.2.2VOL2Page No118 | Providing and fixing unplasticised PVC connection pipe with brass unions :45 cm length 20 mm nominal bore
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 129.8 | 129.8 | 90.0 | False | None | None | False | None | False | 11682.0 | 0 | 3546821 | 128174 | None | Item Code13.34VOL2Page No123 | Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes but without fittings and the base support for tank
---- Work should be carried out as per the direction of engineer incharge of work. | l | 10.62 | 10.62 | 15000.0 | False | None | None | False | None | False | 159300.0 | 0 | 3546822 | 128174 | None | Item Code660VOL5Page NoA-44 | PVC pipes of10 Kg/cm2 for 110mm
---- Work should be carried out as per the direction of engineer incharge of work. | Rmtr | 538.08 | 538.08 | 350.0 | False | None | None | False | None | False | 188328.0 | 0 | 3546823 | 128174 | None | Item Code664VOL5Page NoA-44 | PVC pipes of 10 Kg/cm2 for 200mm
---- Work should be carried out as per the direction of engineer incharge of work. | Rmtr | 1362.9 | 1362.9 | 150.0 | False | None | None | False | None | False | 204435.0 | 0 | 3546824 | 128174 | None | Item Code13.49VOL2Page No125 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes
---- Work should be carried out as per the direction of engineer incharge of work. | Rmtr | 670.24 | 670.24 | 50.0 | False | None | None | False | None | False | 33512.0 | 0 | 3546825 | 128174 | None | Item Code16.60.1VOL5Page No208 | Providing PVC-U INDIVIDUAL U.G.D House service connection (which shall be laid from inside the customer property ) which includes: a) Supply of PVC-U pipe (b) providing and fixing of 315 mm dia the PE Inspection chambres with lid consisting of inlet & outlet arrangements with base, riser of min. 0.42 m depth which includes earth work, fixing in CC-1:2:4 with appurtenances., complete. (c) civil works like Earthwork excavation for the pipeline trenches for laying of PVC-U pipes for the house connections in all types of soils , disintegrated rock,soft rock, hard rock, including cutting of any road using , crossing drains, compound, Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, c.c. wood work, steel work, including T & P and scaffolding wherever necessary sorting the dismantled material, disposal of unserviceable and stacking the serviceable material with all lifts and lead , restoring the damaged portions inside or outside the property premises, refilling the portions of trenches that are dug open including linking to existing sewer network with appurtenances. complete.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 9598.12 | 9598.12 | 45.0 | False | None | None | False | None | False | 431915.4 | 0 | 3546826 | 128174 | None | Item Code16.15.1VOL5Page No192 | Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia Circ.B M.H Constructing Brick Masonry Circular Machinehole 1.2 m internal dia1.0 M depth & SFRC cover & frame
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 34275.46 | 34275.46 | 12.0 | False | None | None | False | None | False | 411305.52 | 0 | 3546827 | 128174 | None | Item Code14.29VOL2Page No135 | Providing and fixing 100 mm sand cast Iron grating for gully trap.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 55.46 | 55.46 | 60.0 | False | None | None | False | None | False | 3327.6 | 0 | 3546828 | 128174 | None | Item Code13.22.1.2VOL2Page No120 | Providing and fixing PTMT grating of approved quality and colour 125 mm nominal dia
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 51.92 | 51.92 | 60.0 | False | None | None | False | None | False | 3115.2 | 0 | 3546829 | 128174 | None | ITEM CODE1.4.1 VOL1PGNO 5 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- Work should be carried out as per the direction of engineer incharge of work. | No | 285.56 | 285.56 | 30.0 | False | None | None | False | None | False | 8566.8 | 0 | 3546830 | 128174 | None | Item Code1.90VOL1Page NO7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 313.88 | 313.88 | 30.0 | False | None | None | False | None | False | 9416.4 | 0 | 3546831 | 128174 | None | Item13.33.10VolNo2P.No123 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge. External work - 150mm nominal dia pipes
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 6261.08 | 6261.08 | 30.0 | False | None | None | False | None | False | 187832.4 | 0 | 3546832 | 128174 | None | Item16.9VolNo5P.No191 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover
---- Work should be carried out as per the direction of engineer incharge of work. | No | 6435.72 | 6435.72 | 20.0 | False | None | None | False | None | False | 128714.4 | 0 |
| 1721369397000 | 0 | None | None | Buildings | Compound Wall | 5499591.31 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546833 | 128175 | None | Item Code1.12VOL1Page No8 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 112.1 | 112.1 | 108.0 | False | None | None | False | None | False | 12106.8 | 0 | 3546834 | 128175 | None | Item Code1.14.1VOL1Page No8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 120.36 | 120.36 | 401.23 | False | None | None | False | None | False | 48292.0428 | 0 | 3546835 | 128175 | None | Item Code1.9VOL1Page No7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 313.88 | 313.88 | 356.65 | False | None | None | False | None | False | 111945.302 | 0 | 3546836 | 128175 | None | Item Code2.1.4VOL1Page No15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately.Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7336.06 | 7336.06 | 48.04 | False | None | None | False | None | False | 352424.3224 | 0 | 3546837 | 128175 | None | Item Code2.11aVOL1Page No18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification
---- Work should be carried out as per the direction of engineer incharge of work. | t | 105559.26 | 105559.26 | 13.4663 | False | None | None | False | None | False | 1421492.662938 | 0 | 3546838 | 128175 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Isolated Footing
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 60.16 | False | None | None | False | None | False | 441479.3472 | 0 | 3546839 | 128175 | None | SINo1aVOL1Page No111 | Formwork, Centering & Scaffloding 8% For Isolated Footing
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 587.07 | 587.07 | 60.16 | False | None | None | False | None | False | 35318.1312 | 0 | 3546840 | 128175 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Columns
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 36.8 | False | None | None | False | None | False | 270053.856 | 0 | 3546841 | 128175 | None | SINo9VOL1Page No111 | Formwork, Centering & Scaffloding 70% For Columns
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 5136.89 | 5136.89 | 36.8 | False | None | None | False | None | False | 189037.552 | 0 | 3546842 | 128175 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Beams
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 16.9 | False | None | None | False | None | False | 124019.298 | 0 | 3546843 | 128175 | None | SL 14VOL1Page No112 | Formwork, Centering & Scaffloding 60% For Beams
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 4403.05 | 4403.05 | 16.9 | False | None | None | False | None | False | 74411.545 | 0 | 3546844 | 128175 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Curtain wall
Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade. Curtain wall
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 37.95 | False | None | None | False | None | False | 278493.039 | 0 | 3546845 | 128175 | None | SINo11VOL1Page No112 | Formwork, Centering & Scaffloding 10% For Curtain wall
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 733.84 | 733.84 | 37.95 | False | None | None | False | None | False | 27849.228 | 0 | 3546846 | 128175 | None | Item Code6.80VOL2Page No14 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 9403.42 | 9403.42 | 125.32 | False | None | None | False | None | False | 1178436.5944 | 0 | 3546847 | 128175 | None | Item Code11.57.1VOL2Page No95 | Fencing with G.I. barbed wire Angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire
---- Work should be carried out as per the direction of engineer incharge of work. | m | 21.24 | 21.24 | 1150.8 | False | None | None | False | None | False | 24442.992 | 0 | 3546848 | 128175 | None | Item Code8.2.1VOL2Page No41 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 348.1 | 348.1 | 1182.04 | False | None | None | False | None | False | 411468.124 | 0 | 3546849 | 128175 | None | Item Code8.30VOL2Page No46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 205.32 | 205.32 | 1182.04 | False | None | None | False | None | False | 242696.4528 | 0 | 3546850 | 128175 | None | Item Code11.25.2VOL2Page No84 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Kg | 160.48 | 160.48 | 756.0 | False | None | None | False | None | False | 121322.88 | 0 | 3546851 | 128175 | None | Item Code11.57.2VOL2Page No95 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.
---- Work should be carried out as per the direction of engineer incharge of work. | Kg | 133.34 | 133.34 | 864.0 | False | None | None | False | None | False | 115205.76 | 0 | 3546852 | 128175 | None | Item Code1.14.1VOL1Page No18 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 428.34 | 428.34 | 44.58 | False | None | None | False | None | False | 19095.3972 | 0 |
| 1721369397000 | 0 | None | None | Buildings | Drain | 4835769.61 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546853 | 128176 | None | Item Code1.14.1VOL1Page No8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m (Vol 1, P No -8, I No-1.14.1)
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 120.36 | 120.36 | 556.55 | False | None | None | False | None | False | 66986.358 | 0 | 3546854 | 128176 | None | Item Code2.1.3VOL1Page No15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (Vol 1, P No -15, I NO: 2.1.3)
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7067.02 | 7067.02 | 75.65 | False | None | None | False | None | False | 534620.063 | 0 | 3546855 | 128176 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 ( Vol 1, P No -18 ; I NO -2.10c)
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 260.75 | False | None | None | False | None | False | 1913493.015 | 0 | 3546856 | 128176 | None | SINo4VOL1Page No111 | Formwork, Centering & Scaffloding 35% For Cement concrete drains ---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 2568.45 | 2568.45 | 260.75 | False | None | None | False | None | False | 669723.3375 | 0 | 3546857 | 128176 | None | Item Code2.11aVOL1Page No18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Vol 1, P No -18 ; I NO -2.11 (a))
---- Work should be carried out as per the direction of engineer incharge of work. | t | 105559.26 | 105559.26 | 15.64 | False | None | None | False | None | False | 1650946.8264 | 0 |
| 1721369397000 | 0 | None | None | Buildings | Concrete Road | 3306891.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546858 | 128177 | None | Item Code1.12VOL1Page No8 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 112.1 | 112.1 | 700.0 | False | None | None | False | None | False | 78470.0 | 0 | 3546859 | 128177 | None | Item Code3.11(310)VOL3Page No18 | Preparation and surface treatment of formation by removing mud and slurry, watering to the extent needed to maintain the desired moisture content, trimming to the required line, grade, profile and rolling with 8-10 t smooth wheeled roller, complete as per clause 310.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 4.72 | 4.72 | 1750.0 | False | None | None | False | None | False | 8260.0 | 0 | 3546860 | 128177 | None | Item Code4.9iVOL3Page No24 | Construction of Granular Sub Base by providing graded Material, mixing with cement in a mechanical mix plant at OMC carriage of mixed material to work site spreading in a uniform layer with mechanical paver on prepared surface and compaction with vibratory power roller to achieve the desired density complete as per clause 401 (2.5% Cement) Grading III materials
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3426.72 | 3426.72 | 175.0 | False | None | None | False | None | False | 599676.0 | 0 | 3546861 | 128177 | None | Item Code4.17(406)VOL3Page No26 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 3019.62 | 3019.62 | 175.0 | False | None | None | False | None | False | 528433.5 | 0 | 3546862 | 128177 | None | Item Code16.28(1501)VOL3Page No149 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14- days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7969.72 | 7969.72 | 262.5 | False | None | None | False | None | False | 2092051.5 | 0 |
| 1721369397000 | 0 | None | None | Buildings | Pathway | 1382358.2 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546863 | 128178 | None | Item Code1.14.1VOL1Page No8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 120.36 | 120.36 | 105.0 | False | None | None | False | None | False | 12637.8 | 0 | 3546864 | 128178 | None | Item Code4.9iVOL3Page No24 | Construction of Granular Sub Base by providing graded Material, mixing with cement in a mechanical mix plant at OMC carriage of mixed material to work site spreading in a uniform layer with mechanical paver on prepared surface and compaction with vibratory power roller to achieve the desired density complete as per clause 401 (2.5% Cement) Laying using Mechanical Paver Grading IV materials
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3460.94 | 3460.94 | 52.5 | False | None | None | False | None | False | 181699.35 | 0 | 3546865 | 128178 | None | Item Code2.1.3VOL1Page No15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) vMix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7067.02 | 7067.02 | 52.5 | False | None | None | False | None | False | 371018.55 | 0 | 3546866 | 128178 | None | Item Code9.25VOL2Page No63 | Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 944.0 | 944.0 | 525.0 | False | None | None | False | None | False | 495600.0 | 0 | 3546867 | 128178 | None | Item Code8.42.3VOL3Page No74 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 150 mm Kerb Stone
---- Work should be carried out as per the direction of engineer incharge of work. | m | 546.34 | 546.34 | 500.0 | False | None | None | False | None | False | 273170.0 | 0 | 3546868 | 128178 | None | Item Code8.10(803)VOL3Page No66 | Painting Two Coats on New Concrete Surfaces Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 128.62 | 128.62 | 375.0 | False | None | None | False | None | False | 48232.5 | 0 |
| 1721369397000 | 0 | None | None | Buildings | Borewell | 900500.94 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546869 | 128179 | None | Item Code12.4VOL5Page No140 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 33% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 6239.84 | 6239.84 | 2.0 | False | None | None | False | None | False | 12479.68 | 0 | 3546870 | 128179 | None | Item Code12.1VOL5Page No139 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )
---- Work should be carried out as per the direction of engineer incharge of work. | Rmtr | 436.6 | 436.6 | 100.0 | False | None | None | False | None | False | 43660.0 | 0 | 3546871 | 128179 | None | Item Code12.1.2VOL5Page No139 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )
50-100Mtrs
---- Work should be carried out as per the direction of engineer incharge of work. | Rmtr | 547.52 | 547.52 | 100.0 | False | None | None | False | None | False | 54752.0 | 0 | 3546872 | 128179 | None | Item Code12.1.3VOL5Page No139 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )
100-150 Mtrs.
---- Work should be carried out as per the direction of engineer incharge of work. | Rmtr | 581.74 | 581.74 | 100.0 | False | None | None | False | None | False | 58174.0 | 0 | 3546873 | 128179 | None | Item Code12.1.4VOL5Page No139 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete )
150-200 Mtrs.
---- Work should be carried out as per the direction of engineer incharge of work. | Rmtr | 674.96 | 674.96 | 100.0 | False | None | None | False | None | False | 67496.0 | 0 | 3546874 | 128179 | None | Item Code12.32VOL5Page No143 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.
---- Work should be carried out as per the direction of engineer incharge of work. | Rmtr | 2280.94 | 2280.94 | 60.0 | False | None | None | False | None | False | 136856.4 | 0 | 3546875 | 128179 | None | Item Code12.34VOL5Page No143 | Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 193.52 | 193.52 | 2.0 | False | None | None | False | None | False | 387.04 | 0 | 3546876 | 128179 | None | Item13.13.6Vol5P.No151 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5 HP
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 37921.66 | 37921.66 | 2.0 | False | None | None | False | None | False | 75843.32 | 0 | 3546877 | 128179 | None | Item11.3.6Vol5P.No127 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Heavy Duty GI pipe:
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 801.22 | 801.22 | 300.0 | False | None | None | False | None | False | 240366.0 | 0 | 3546878 | 128179 | None | Item13.22.3Vol5P.No154 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 159.3 | 159.3 | 320.0 | False | None | None | False | None | False | 50976.0 | 0 | 3546879 | 128179 | None | Item13.32Vol5P.No156 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.
---- Work should be carried out as per the direction of engineer incharge of work. | Job | 7670.0 | 7670.0 | 2.0 | False | None | None | False | None | False | 15340.0 | 0 | 3546880 | 128179 | None | Electrical SR 2023-24 Vol 6Item No5.42.2 Pg No20 | Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with
hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete."
---- Work should be carried out as per the direction of engineer incharge of work. | Sq CM | 19500.0 | 19500.0 | 1.04 | False | None | None | False | None | False | 20280.0 | 0 | 3546881 | 128179 | None | Electrical SR 2023-24 Vol 6Item No5.41.3 Pg No20 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 654.9 | 654.9 | 4.0 | False | None | None | False | None | False | 2619.6 | 0 | 3546882 | 128179 | None | Electrical SR 2023-24 Vol 6Item No3.1.2 Pg No8 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 173.46 | 173.46 | 2.0 | False | None | None | False | None | False | 346.92 | 0 | 3546883 | 128179 | None | Electrical SR 2023-24 Vol 6Item No2.3.3 Pg No5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12
---- Work should be carried out as per the direction of engineer incharge of work. | m | 49.56 | 49.56 | 20.0 | False | None | None | False | None | False | 991.2 | 0 | 3546884 | 128179 | None | Electrical SR 2023-24 Vol 6Item No2.3.3 Pg No5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12
---- Work should be carried out as per the direction of engineer incharge of work. | m | 69.62 | 69.62 | 30.0 | False | None | None | False | None | False | 2088.6 | 0 | 3546885 | 128179 | None | Electrical SR 2023-24 Vol 6Item No5.7.2Pg No14 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 284.38 | 284.38 | 2.0 | False | None | None | False | None | False | 568.76 | 0 | 3546886 | 128179 | None | Electrical SR 2023-24 Vol 6Item No5.18.9Pg No18 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 3643.84 | 3643.84 | 2.0 | False | None | None | False | None | False | 7287.68 | 0 | 3546887 | 128179 | None | Electrical SR 2023-24 Vol 6Item No5.20.8Pg No18 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board.
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 6073.46 | 6073.46 | 2.0 | False | None | None | False | None | False | 12146.92 | 0 | 3546888 | 128179 | None | Electrical SR 2023-24 Vol 6Item No13.17.1Pg No57 | Fixing a shunt capacitor of . KVAR capacity with necessary clamps, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor.
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 318.6 | 318.6 | 6.0 | False | None | None | False | None | False | 1911.6 | 0 | 3546889 | 128179 | None | Electrical SR 2023-24 Vol 6Item No5.38Pg No19 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 607.7 | 607.7 | 2.0 | False | None | None | False | None | False | 1215.4 | 0 | 3546890 | 128179 | None | Electrical SR 2023-24 Vol 6Item No1.6.1Pg No43 | Digging of Pit for providing GI Pipe type Earthing
---- Work should be carried out as per the direction of engineer incharge of work. | Per Pit | 895.62 | 895.62 | 2.0 | False | None | None | False | None | False | 1791.24 | 0 | 3546891 | 128179 | None | Electrical SR 2023-24 Vol 6Item No51.01Pg No22 | GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg
---- Work should be carried out as per the direction of engineer incharge of work. | No | 876.74 | 876.74 | 2.0 | False | None | None | False | None | False | 1753.48 | 0 | 3546892 | 128179 | None | Electrical SR 2023-24 Vol 6Item No51.02Pg No22 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each
---- Work should be carried out as per the direction of engineer incharge of work. | No | 797.68 | 797.68 | 2.0 | False | None | None | False | None | False | 1595.36 | 0 | 3546893 | 128179 | None | Electrical SR 2023-24 Vol 6Item No51.03Pg No22 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag
---- Work should be carried out as per the direction of engineer incharge of work. | Bag | 356.8 | 356.8 | 2.0 | False | None | None | False | None | False | 713.6 | 0 | 3546894 | 128179 | None | Electrical SR 2023-24 Vol 6Item No32.03Pg No13 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975
---- Work should be carried out as per the direction of engineer incharge of work. | Km | 139244.72 | 139244.72 | 0.03 | False | None | None | False | None | False | 4177.3416 | 0 | 3546895 | 128179 | None | Electrical SR 2023-24 Vol 6Item No21.05Pg No52 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable
---- Work should be carried out as per the direction of engineer incharge of work. | Km | 24645.48 | 24645.48 | 0.02 | False | None | None | False | None | False | 492.9096 | 0 | 3546896 | 128179 | None | CSRVol-1Item No.1.17.1 Pg No 10 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 309.16 | 309.16 | 7.5 | False | None | None | False | None | False | 2318.7 | 0 | 3546897 | 128179 | None | Schedule Of Rates PWD, VOL 1 Item No.1.10 Pgno.7 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 160.0 | 160.0 | 7.5 | False | None | None | False | None | False | 1200.0 | 0 | 3546898 | 128179 | None | Electrical SR 2023-24 Vol 6Item No28.08Pg No56 | Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete.
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 109.74 | 109.74 | 8.0 | False | None | None | False | None | False | 877.92 | 0 | 3546899 | 128179 | None | Electrical SR 2023-24 Vol 6Item No35.01Pg No15 | Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable
---- Work should be carried out as per the direction of engineer incharge of work. | Set | 382.32 | 382.32 | 2.0 | False | None | None | False | None | False | 764.64 | 0 | 3546900 | 128179 | None | Schedule Of Rates PWD, Electrical SR 2019-20 Item | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 22.42 | 22.42 | 12.0 | False | None | None | False | None | False | 269.04 | 0 | 3546901 | 128179 | None | Electrical SR 2023-24 Vol 6Item No5.35Pg No19 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter.
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 6731.9 | 6731.9 | 2.0 | False | None | None | False | None | False | 13463.8 | 0 | 3546902 | 128179 | None | CSR 2023-24, Vol- 1, Item No: 1.4.1,Page No-29 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 293.82 | 293.82 | 1.536 | False | None | None | False | None | False | 451.30752 | 0 | 3546903 | 128179 | None | CSR 2023-24, Vol- 1, Item No: 2.1.5,Page No-15 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. ( The cost of steel reinforcement shall be paid separately).PCC 1:2:4 using 40 mm aggregate
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7264.08 | 7264.08 | 0.512 | False | None | None | False | None | False | 3719.20896 | 0 | 3546904 | 128179 | None | CSR 2023-24, Vol - 2 Item No: 5.4,Page No-9 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7539.02 | 7539.02 | 1.8 | False | None | None | False | None | False | 13570.236 | 0 | 3546905 | 128179 | None | VOL 5 2023-24, Item 10.6 ,Page No-116 | RCC hume pipe Circular pump house: Supplying precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 19353.18 | 19353.18 | 2.0 | False | None | None | False | None | False | 38706.36 | 0 | 3546906 | 128179 | None | VOL 5 2023-24, Item 10.7 ,Page No-116 | Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work.
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 2220.76 | 2220.76 | 2.0 | False | None | None | False | None | False | 4441.52 | 0 | 3546907 | 128179 | None | CSR 2023-24 Item No: 8.40,Page No-48, Vol - 2 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as
per directions of Engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 135.7 | 135.7 | 20.738 | False | None | None | False | None | False | 2814.1466 | 0 | 3546908 | 128179 | None | CSR 2023-24 Item No: 8.30,Page No-63, Vol - 3 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade English and Roman
---- Work should be carried out as per the direction of engineer incharge of work. | cm | 15.93 | 15.93 | 100.0 | False | None | None | False | None | False | 1593.0 | 0 |
| 1721369397000 | 0 | None | None | Buildings | RO Plant | 385860.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546909 | 128180 | None | Item no: 21.1.7 VOL5 Page No247 | Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components For 500 LPH SS : Skid Type (Page no: 247, Item no: 21.1.7
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 385860.0 | 385860.0 | 1.0 | False | None | None | False | None | False | 385860.0 | 0 |
| 1721369397000 | 0 | None | None | Buildings | Sump tank | 528369.08 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546910 | 128181 | None | Item Code1.14.1VOL1Page No8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 120.36 | 120.36 | 55.2 | False | None | None | False | None | False | 6643.872 | 0 | 3546911 | 128181 | None | Item Code1.9VOL1Page No34 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 313.88 | 313.88 | 20.7 | False | None | None | False | None | False | 6497.316 | 0 | 3546912 | 128181 | None | Item Code2.1.4VOL1Page No15 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:3:6 Using 20 mm and down size graded crushed coarse aggregates
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7336.06 | 7336.06 | 1.5 | False | None | None | False | None | False | 11004.09 | 0 | 3546913 | 128181 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 3.0 | False | None | None | False | None | False | 22015.26 | 0 | 3546914 | 128181 | None | SINo1aVOL1Page No111 | Formwork, Centering & Scaffloding 8% For Isolated Footing
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 587.07 | 587.07 | 3.0 | False | None | None | False | None | False | 1761.21 | 0 | 3546915 | 128181 | None | SINo1aVOL1Page No111 | Formwork, Centering & Scaffloding 8% For Isolated Footingsump tank-walls
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 5.76 | False | None | None | False | None | False | 42269.2992 | 0 | 3546916 | 128181 | None | SINo11VOL1Page No112 | Formwork, Centering & Scaffloding 10% For Earth retaining structures
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 733.84 | 733.84 | 5.76 | False | None | None | False | None | False | 4226.9184 | 0 | 3546917 | 128181 | None | SINo11VOL1Page No112 | Formwork, Centering & Scaffloding 10% For Earth retaining structures
Cover slab
Collection sump
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 3.0 | False | None | None | False | None | False | 22015.26 | 0 | 3546918 | 128181 | None | SINo15VOL1Page No112 | Formwork, Centering & Scaffloding 50% For Roof Slab
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3669.21 | 3669.21 | 3.0 | False | None | None | False | None | False | 11007.63 | 0 | 3546919 | 128181 | None | Item Code8.12VOL2Page No43 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 75.52 | 75.52 | 20.4 | False | None | None | False | None | False | 1540.608 | 0 | 3546920 | 128181 | None | Item Code8.12VOL2Page No43 | sump tank-walls
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 75.52 | 75.52 | 39.17 | False | None | None | False | None | False | 2958.1184 | 0 | 3546921 | 128181 | None | Item Code8.12VOL2Page No43 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge.
Cover slab
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 75.52 | 75.52 | 20.4 | False | None | None | False | None | False | 1540.608 | 0 | 3546922 | 128181 | None | Item Code2.11AVOL1Page No18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
---- Work should be carried out as per the direction of engineer incharge of work. | t | 105559.26 | 105559.26 | 1.47 | False | None | None | False | None | False | 155172.1122 | 0 | 3546923 | 128181 | None | Item Code15.2VOL2Page No149 | Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 869.66 | 869.66 | 43.8 | False | None | None | False | None | False | 38091.108 | 0 | 3546924 | 128181 | None | Item Code8.3.1VOL2Page No41 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 417.72 | 417.72 | 43.8 | False | None | None | False | None | False | 18296.136 | 0 | 3546925 | 128181 | None | Item Code18.3VOL5Page No221 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 2315.16 | 2315.16 | 2.0 | False | None | None | False | None | False | 4630.32 | 0 | 3546926 | 128181 | None | Item Code13.33.9VOL2Page No129 | Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.External on wall - 100mm nominal dia pipes
Providing & fixing Chorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction Engineer in Charge.External on wall - 100mm nominal dia pipes
---- Work should be carried out as per the direction of engineer incharge of work. | m | 2978.32 | 2978.32 | 60.0 | False | None | None | False | None | False | 178699.2 | 0 |
| 1721369397000 | 0 | None | None | Buildings | Septic & Soakpit tank | 460115.44 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546927 | 128182 | None | Item Code1.14.1VOL1Page No8 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 120.36 | 120.36 | 51.27 | False | None | None | False | None | False | 6170.8572 | 0 | 3546928 | 128182 | None | Item Code2.1.3VOL1Page No15 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7067.02 | 7067.02 | 4.91 | False | None | None | False | None | False | 34699.0682 | 0 | 3546929 | 128182 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 4.22 | False | None | None | False | None | False | 30968.1324 | 0 | 3546930 | 128182 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 2.85 | False | None | None | False | None | False | 20914.497 | 0 | 3546931 | 128182 | None | SINo11VOL1Page No112 | Formwork, Centering & Scaffloding 10% For Earth retaining structures
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 733.84 | 733.84 | 2.853 | False | None | None | False | None | False | 2093.64552 | 0 | 3546932 | 128182 | None | Item Code2.10cVOL1Page No18 | Providing and laying in position Ready Mixed or Batch Mixed concrete as per IS 10262 mix design procedure for Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary Portland Cement (OPC) @ 75% & GGBS @ 25% proportion, admixtures to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the Engineer-in-charge. RMC M25 Grade.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7338.42 | 7338.42 | 4.02 | False | None | None | False | None | False | 29500.4484 | 0 | 3546933 | 128182 | None | SINo15VOL1Page No112 | Formwork, Centering & Scaffloding 50% For Roof Slab
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 3669.21 | 3669.21 | 4.0206 | False | None | None | False | None | False | 14752.425726 | 0 | 3546934 | 128182 | None | Item Code2.11AVOL1Page No18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
---- Work should be carried out as per the direction of engineer incharge of work. | t | 105559.26 | 105559.26 | 1.3862 | False | None | None | False | None | False | 146326.246212 | 0 | 3546935 | 128182 | None | Item Code6.32VOL2Page No17 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 1545.8 | 1545.8 | 30.52 | False | None | None | False | None | False | 47177.816 | 0 | 3546936 | 128182 | None | Item Code8.8VOL2Page No42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Out side)
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 437.78 | 437.78 | 81.61 | False | None | None | False | None | False | 35727.2258 | 0 | 3546937 | 128182 | None | Item Code8.12VOL2Page No43 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 75.52 | 75.52 | 33.0 | False | None | None | False | None | False | 2492.16 | 0 | 3546938 | 128182 | None | Item Code8.1.2VOL2Page No41 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 284.38 | 284.38 | 26.8 | False | None | None | False | None | False | 7621.384 | 0 | 3546939 | 128182 | None | Item Code18.3VOL5Page No221 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary lockingarrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 2315.16 | 2315.16 | 5.0 | False | None | None | False | None | False | 11575.8 | 0 | 3546940 | 128182 | None | Item Code13.33.9VOL2Page No123 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching refilling & testing of joints complete, as per direction of engineer in charge (External work) 100mm nominal dia pipes
---- Work should be carried out as per the direction of engineer incharge of work. | Rmtr | 2978.32 | 2978.32 | 20.0 | False | None | None | False | None | False | 59566.4 | 0 | 3546941 | 128182 | None | Item Code17.1VOL2Page No175 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 1182.36 | 1182.36 | 6.81 | False | None | None | False | None | False | 8051.8716 | 0 | 3546942 | 128182 | None | SINo1aVOL1Page No111 | Formwork, Centering & Scaffloding 8% For Isolated Footing
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 587.07 | 587.07 | 4.22 | False | None | None | False | None | False | 2477.4354 | 0 |
| 1721369397000 | 0 | None | None | Buildings | Rainwater harvesting | 319505.23 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546943 | 128183 | None | RDW&S Page No86 Item Code 11.20.1 | Supplying and erection of RCC rings of Well steining of 0.3Mtr depth using M20 grade concrete using clean graded granite or trap or jelly of approved quality 20mm and down size well compacted including centering ,formwork and plastering for both faces with C.M 1:3 proportion as per design using 6.50mm M.S Coil at the rate of10Kgs/ring including cost of steel and fabrication ,bailing out of water,errection etc.,complete For 1.80m dia (clear)rings of steining thickness 0.075mm upto 18M depth
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 1787.7 | 1787.7 | 100.0 | False | None | None | False | None | False | 178770.0 | 0 | 3546944 | 128183 | None | Item1.6.1VolNo1P.No6 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work In all kinds of soils. Depth upto 1.50m
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 571.12 | 571.12 | 38.16 | False | None | None | False | None | False | 21793.9392 | 0 | 3546945 | 128183 | None | Item Code1.9VOL1PageNo7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 313.88 | 313.88 | 21.2 | False | None | None | False | None | False | 6654.256 | 0 | 3546946 | 128183 | None | Item Code2.1.3VOL1PageNo15 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7067.02 | 7067.02 | 1.7 | False | None | None | False | None | False | 12013.934 | 0 | 3546947 | 128183 | None | Item Code17.1VOL2PageNo175 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 1182.36 | 1182.36 | 3.41 | False | None | None | False | None | False | 4031.8476 | 0 | 3546948 | 128183 | None | Item Code17.2VOL2PageNo175 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineering-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 1399.48 | 1399.48 | 3.41 | False | None | None | False | None | False | 4772.2268 | 0 | 3546949 | 128183 | None | Item Code17.3VOL2PageNo175 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 1406.56 | 1406.56 | 3.41 | False | None | None | False | None | False | 4796.3696 | 0 | 3546950 | 128183 | None | Item Code2.5.2VOL1Page No16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Roof Slab
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 8074.74 | 8074.74 | 3.84 | False | None | None | False | None | False | 31007.0016 | 0 | 3546951 | 128183 | None | SL 15VOL1Page No112 | Formwork, Centering & Scaffloding 50% For Roof Slab
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 4037.37 | 4037.37 | 3.8 | False | None | None | False | None | False | 15342.006 | 0 | 3546952 | 128183 | None | Item Code2.11aVOL1Page No18 | Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings
---- Work should be carried out as per the direction of engineer incharge of work. | t | 105559.26 | 105559.26 | 0.382 | False | None | None | False | None | False | 40323.63732 | 0 |
| 1721369397000 | 0 | None | None | Buildings | Furniture | 6953972.56 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546953 | 128184 | None | 2023-24 SR KSFIC.DWD-096 Page No7 | Teak Wood Dias Table : Of size L-6'xW-36"xH-30". Made out of Teak wood Dias Table leg size3"x3". Table Top patti- 4"x1.25" and bottom portion shall be 2"x1". The top of the Table shall be provided with 18mm OST. Table top and Front should be provided with Blazer Cloth. Table top should be provided with 6mm plain glass with Diamond polish. Table shall be neatly finished and polished.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 35223.0 | 35223.0 | 1.0 | False | None | None | False | None | False | 35223.0 | 0 | 3546954 | 128184 | None | 2023-24 SR KSFIC.DWD - 075 Page No5 | Providing and fixing Wooden Platform : Made out of teak wood of section 50x50mm of legs, 50x50mm for horizontals both at suitable intervals from the point of view of stability, the top of the platform covered with commercial block board of 25mm thick, all sides covered with 6mm thick one side teak plywood fixed firmly to the platform including joining the wooden sections properly using nails/ screws, fevicol including cost of wood, nails/screws, fevicol, cost of painting/polishing, labour, all lead and lift, cost of any incidental charges etc.(Rate Per Sq.Mtr)
---- Work should be carried out as per the direction of engineer incharge of work. | Sqm | 9605.2 | 9605.2 | 9.07 | False | None | None | False | None | False | 87119.164 | 0 | 3546955 | 128184 | None | 2023-24 SRKSFIC.DWD - 094 Page No7 | Teak Wood Horse Shoe Table : Of size overall Length 16'. L-12' x Width 2' or 2.5'x Height 2.5' =2 Nos. & 4' one "U" shape Table, such that when three table joined together and make one Horse shoe table. Leg size 2.5"x2.5" turning legs. Table upper portion patti of 4"x1.25" and bottom patti 2"x1.5". Top should be OST covered with Green cloth on top and front portion. Top should be provided with 8mm glass with Diamond polish. The Table shall be neatly finished and polished.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 195880.0 | 195880.0 | 1.0 | False | None | None | False | None | False | 195880.0 | 0 | 3546956 | 128184 | None | 2023-24 SR KSFIC.DWD - 098 Page No7 | Teak Wood Witness Box : Length 4'xWidth 2.5'xHeight 4', made out of Teak wood legs (turning) size 4"x4" with side bars 3"x2". The Height from the ground shall be 6" with 18mm OST . Back Jungle wood support. All the sides shall be covered by 2"x2" reapers with suitable gap in between. The Witness Box shall be neatly finished and polished
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 51825.6 | 51825.6 | 1.0 | False | None | None | False | None | False | 51825.6 | 0 | 3546957 | 128184 | None | 2023-24 SR KSFIC.DWD - 100 Page No7 | Teak Wood Accused Dock : Of size Length 8'xwidth 3'xHeight 4' with wooden platform. Made out of Teak wood leg size 4""x4"". Side bars shall be 2""x2"" . All the side shall be covered with 2""x1"" reapers with suitable gap in between. A side door shall also be provided with locking device. The height of the Accused Dock from the ground shall be 6. The Accused Dock shall be neatly finished
and polished.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 84936.0 | 84936.0 | 1.0 | False | None | None | False | None | False | 84936.0 | 0 | 3546958 | 128184 | None | 2023-24 SR KSFIC.DWD - 052 Page No4 | Teak Wood Typist & Computer Table (Size 4'X2') : Size: 121.92 L x 60.9cm B x 76.2cm H, Legs 4.44cm x 4.44 cm 6 nos. Side cross bars 10.16 x 2.54 cm Bottom portion 5.08 x 2.54 cm with 3 drawers or one small drawer and one cupboard on right side with 12mm OST Coverage. Top shall be made out of 1.90cm OST locking arrangements shall be provided. With Key board.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 29901.2 | 29901.2 | 10.0 | False | None | None | False | None | False | 299012.0 | 0 | 3546959 | 128184 | None | 2023-24 SR KSFIC.DWD - 048 Page No3 | Teak Wood Table : Of size-5'x2.5' or 5'x3'. Made out of Teak wood Legs of size 2.25"x2.25". All patties below the top to be of 4"x1.25". The storage on the right should be with one Drawer & one cupboard. The Door frame and the other 3 sides to be made out of Teak wood Frame of size 3"x1.25" and panels of OST pre laminated sheet of 12mm thickness . Top to be made out of OST pre laminated sheet of 18mm thickness with Teak wood edge bending. Complete with all accessories like 2 locks and handles. The Table shall be neatly finished and polished.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 41252.8 | 41252.8 | 57.0 | False | None | None | False | None | False | 2351409.6 | 0 | 3546960 | 128184 | None | 2023-24 SR KSFIC.DWD - 060 Page No4 | Teak Wood Table : Of size 7' X 3' Laminated Top all patties below the top to be of 4”x1.25”. Leg size 2.25”x2.25”. One side 2(or 3) drawers and another side 1 cabinet with shelf. Table 3 side closed with OST pre laminated sheet 12mm thickness. Complete with all accessories like 2 locks and handles with polish. Table shall be neatly finished and polished.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 49088.0 | 49088.0 | 7.0 | False | None | None | False | None | False | 343616.0 | 0 | 3546961 | 128184 | None | 2023-24 SR KSFIC.DWD - 043 Page No3 | Teak Wood Table (Size 3'X2') : With Teak Wood Beading. Made out of teak wood leg size 2" x 2" . Table upper side patti 4" x 1.25" . Lower side H shape middle 1 patti . The Table shall be neatly finished and polished.
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 13192.4 | 13192.4 | 4.0 | False | None | None | False | None | False | 52769.6 | 0 | 3546962 | 128184 | None | 2023-24 SR KSFIC.DWD - 097 Page No7 | Teak Wood Dias Railing :- Made out of 3"x3" turning legs, affixed together in 2"x1" patti at top & bottom maintaining a distance of 12" between every leg. Further finished with 3"x1.5" pattis on top and bottom, such that the flat surface is seen above. To be fixed on site with necessary screws, embeded in the floor. (Per Running Meter )
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 10738.0 | 10738.0 | 12.0 | False | None | None | False | None | False | 128856.0 | 0 | 3546963 | 128184 | None | 2023-24 SR KSFIC.DWD - 101 Page No7 | Teak Wood Ornamental Chair with Lobo : Made out of Teak Wood, Rear leg of height 4'6" and 2.5"x1.5" section and front leg of height 18" with 2.5"x2.5" section with curve shape. Seat frame of size 3"x1.5" with bottom 'H' type supports for legs. Seat and back to be made out of 32 density foam with cloth. The carms and the back to be shaped as per deisgn. Chair shall be neatly finished and polished.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 30444.0 | 30444.0 | 1.0 | False | None | None | False | None | False | 30444.0 | 0 | 3546964 | 128184 | None | 2023-24 SR KSFIC.DWD - 067 Page No5 | Teak Wood Revolving Chair : Chair upper construction seasoned teak wood with melomon polish, Stain less steel 5 caster wheel legs, Hydraulic height adjustment. The Chair shall be neatly finished and polished
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 16850.4 | 16850.4 | 1.0 | False | None | None | False | None | False | 16850.4 | 0 | 3546965 | 128184 | None | 2023-24 SR KSFIC.DWD - 111 Page No8 | Director Cushion Chair: High back chair with seat and back High quality feather touch Rexine. Arms with cushioning. Chair to have SS base with 5 Caster wheel legs along with Syncro Mechanisum.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 14868.0 | 14868.0 | 57.0 | False | None | None | False | None | False | 847476.0 | 0 | 3546966 | 128184 | None | 2023-24 SR KSFIC.DWD - 112 Page No8 | High Back Cushion Chair :- High back Chair with seat and back high quality feather touch Rexin. Arms with cushioning. Chair to have 5 caster wheel legs with Syncro Mechanisum.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 21216.4 | 21216.4 | 2.0 | False | None | None | False | None | False | 42432.8 | 0 | 3546967 | 128184 | None | 2023-24 SR KSFIC.DWD - 091 Page No6 | Teak Wood Stool: Height 21", 14" X 14" or 24"x14"x14" top teak wood planks legs size 2" X 2". thickness with bottom supporting patties of size 2"x1" section. Top to be Teak Wood planks.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 7221.6 | 7221.6 | 6.0 | False | None | None | False | None | False | 43329.6 | 0 | 3546968 | 128184 | None | 2023-24 SR KSFIC.DWD - 088 Page No6 | Notice Board: Of size 4'x3' using 18mm plywood for body, back 8mm plywood and 12mm soft board with cloth. And 5mm plain glass for door with lock, and alluminium chanal with teak wood beading. Outerside laminated sheet or veneer with polish, inner side paint or polish.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 18290.0 | 18290.0 | 2.0 | False | None | None | False | None | False | 36580.0 | 0 | 3546969 | 128184 | None | 2023-24 SR KSFIC.DWD - 002 Page No1 | Teak Wood Damaru Sofa Set : 1+3+1 with teapoy and cushion, front and back 4"x4" with turning. Sofa side bars 3.5'x1.25". Handle support patti 4"x1.25" and 2"x3", handle 6"x1.25". Seat and back support patti 2.5"x1.25". Sofa set shall be neatly finished and polished.
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 114200.4 | 114200.4 | 1.0 | False | None | None | False | None | False | 114200.4 | 0 | 3546970 | 128184 | None | 2023-24 SR KSFIC.DWD - 017 Page No2 | Teak Wood Side Teapoy : Size 1.3/4' x1.3/4 ' x1.5' made out of 2"x2" legs 2"x1.1/4" and 3"x1.1/4" side bars. Top with 8mm glass & reapers shelf with polish.
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 9841.2 | 9841.2 | 2.0 | False | None | None | False | None | False | 19682.4 | 0 | 3546971 | 128184 | None | 2023-24 SR KSFIC.DWD - 103 Page No7 | Teak Wood Bench With Back : Size : 182.88cm L x 46cm W x 96cm H Legs 4.4 x 4.44cm. Patties at top and bottom around 5.68 x 2.54cm in section and polished seat shall be provided with 18mm block board with laminated sheet on the top of the Block board. Back with Teak wood patti.
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 32096.0 | 32096.0 | 10.0 | False | None | None | False | None | False | 320960.0 | 0 | 3546972 | 128184 | None | GEM ITEM 5116877- 72046465263 | Steel Almera
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 23600.0 | 23600.0 | 52.0 | False | None | None | False | None | False | 1227200.0 | 0 | 3546973 | 128184 | None | GEM ITEM 5116877- 52718973956 | Iron Safe locker box
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 17700.0 | 17700.0 | 2.0 | False | None | None | False | None | False | 35400.0 | 0 | 3546974 | 128184 | None | GEM ITEM 5116877- 26662330406 | Steel three seater chairs
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 11800.0 | 11800.0 | 20.0 | False | None | None | False | None | False | 236000.0 | 0 | 3546975 | 128184 | None | GEM ITEM 5116877- 41482038408 | Steel racks
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 11759.0 | 11759.0 | 30.0 | False | None | None | False | None | False | 352770.0 | 0 |
| 1721369397000 | 0 | None | None | Buildings | Electrification | 5742662.6 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3546976 | 128185 | None | 2023-24 SR VOL6 1.2.1 (2 of 105) | Electrical installation work
Concealed Conduit System :Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary19/20mm dia 2mm thick (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 77.88 | 77.88 | 846.4 | False | None | None | False | None | False | 65917.632 | 0 | 3546977 | 128185 | None | 2023-24 SR VOL6 1.2.2 (2 of 105) | Concealed Conduit System :Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 92.04 | 92.04 | 1900.0 | False | None | None | False | None | False | 174876.0 | 0 | 3546978 | 128185 | None | 2023-24 SR VOL6 1.3.1 (2 of 105) | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20mm dia 2mm thick.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 80.24 | 80.24 | 338.56 | False | None | None | False | None | False | 27166.0544 | 0 | 3546979 | 128185 | None | 2023-24 SR VOL6 1.3.2 (2 of 105) | Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 93.22 | 93.22 | 760.0 | False | None | None | False | None | False | 70847.2 | 0 | 3546980 | 128185 | None | 2023-24 SR VOL6 1.9.2 (3 of 105) | Supplying PVC/GI flexible conduit pipe . mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely25mm.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 25.96 | 25.96 | 100.0 | False | None | None | False | None | False | 2596.0 | 0 | 3546981 | 128185 | None | 2023-24 SR VOL6 2.1.1 (5 of 105) | Point wiring using Copper wire with out switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm (Phase&Neutral) &1x1.0 Sqmm(earth Wire)Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto3mtr from tapping point to out let via Switch.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Point | 336.3 | 336.3 | 33.0 | False | None | None | False | None | False | 11097.9 | 0 | 3546982 | 128185 | None | 2023-24 SR VOL6 2.1.2 5 of 105) | Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Point | 464.92 | 464.92 | 83.0 | False | None | None | False | None | False | 38588.36 | 0 | 3546983 | 128185 | None | 2023-24 SR VOL6 2.1.3 (5 of 105) | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Point | 672.6 | 672.6 | 52.0 | False | None | None | False | None | False | 34975.2 | 0 | 3546984 | 128185 | None | 2023-24 SR VOL6 2.3.2 (5 of 105) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,1.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 30.68 | 30.68 | 607.4 | False | None | None | False | None | False | 18635.032 | 0 | 3546985 | 128185 | None | 2023-24 SR VOL6 2.3.3 (5 of 105) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,2.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 49.56 | 49.56 | 2264.8 | False | None | None | False | None | False | 112243.488 | 0 | 3546986 | 128185 | None | 2023-24 SR VOL6 2.3.4 (5 of 105) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,4 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 74.34 | 74.34 | 1200.0 | False | None | None | False | None | False | 89208.0 | 0 | 3546987 | 128185 | None | 2023-24 SR VOL6 2.3.5 (5 of 105) | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,6 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 108.56 | 108.56 | 1000.0 | False | None | None | False | None | False | 108560.0 | 0 | 3546988 | 128185 | None | 2023-24 SR VOL6 3.4.2 (8 of 105) | Supplying and flush mounting powder coated / galvanized metal box size 1-3way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 187.62 | 187.62 | 10.0 | False | None | None | False | None | False | 1876.2 | 0 | 3546989 | 128185 | None | 2023-24 SR VOL6 3.4.3 (8 of 105) | Supplying and flush mounting powder coated / galvanized metal box size 4-5way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 138.06 | 138.06 | 10.0 | False | None | None | False | None | False | 1380.6 | 0 | 3546990 | 128185 | None | 2023-24 SR VOL6 3.4.5 (8 of 105) | Supplying and flush mounting powder coated / galvanized metal box size 8way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 307.98 | 307.98 | 50.0 | False | None | None | False | None | False | 15399.0 | 0 | 3546991 | 128185 | None | 2023-24 SR VOL6 3.4.6 (8 of 105) | Supplying and flush mounting powder coated / galvanized metal box size 10-12way suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 376.42 | 376.42 | 45.0 | False | None | None | False | None | False | 16938.9 | 0 | 3546992 | 128185 | None | 2023-24 SR VOL6 3.5.2 (8 of 105) | Supplying and fixing superior quality 3Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 189.98 | 189.98 | 10.0 | False | None | None | False | None | False | 1899.8 | 0 | 3546993 | 128185 | None | 2023-24 SR VOL6 3.5.3 (8 of 105) | Supplying and fixing superior quality 4Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 206.5 | 206.5 | 10.0 | False | None | None | False | None | False | 2065.0 | 0 | 3546994 | 128185 | None | 2023-24 SR VOL6 3.5.5 (8 of 105) | Supplying and fixing superior quality 8 modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 335.12 | 335.12 | 50.0 | False | None | None | False | None | False | 16756.0 | 0 | 3546995 | 128185 | None | 2023-24 SR VOL6 3.5.6 (8 of 105) | Supplying and fixing superior quality 10-12Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 405.92 | 405.92 | 45.0 | False | None | None | False | None | False | 18266.4 | 0 | 3546996 | 128185 | None | 2023-24 SR VOL6 3.6.1 (9 of 105) | Supplying and fixing of 6Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 120.36 | 120.36 | 248.0 | False | None | None | False | None | False | 29849.28 | 0 | 3546997 | 128185 | None | 2023-24 SR VOL6 3.6.3 (9 of 105) | Supplying and fixing of 6Amps 3way modular Socketc on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 201.78 | 201.78 | 150.0 | False | None | None | False | None | False | 30267.0 | 0 | 3546998 | 128185 | None | 3.6.4 (9 of 105) | Supplying and fixing of modular stepped fan regulator Two Module on existing modular switch plate as per and IS 1293.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 421.26 | 421.26 | 45.0 | False | None | None | False | None | False | 18956.7 | 0 | 3546999 | 128185 | None | 2023-24 SR VOL6 3.6.7 (9 of 105) | Supplying and fixing of 16Amps 0ne way modular switch on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 212.4 | 212.4 | 20.0 | False | None | None | False | None | False | 4248.0 | 0 | 3547000 | 128185 | None | 2023-24 SR VOL6 3.6.9 (9 of 105) | Supplying and fixing of32Amps modular DP Switch on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 384.68 | 384.68 | 20.0 | False | None | None | False | None | False | 7693.6 | 0 | 3547001 | 128185 | None | 2023-24 SR VOL6 3.6.10 (9 of 105) | Supplying and fixing of 6/16amps modular Universal Socket on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 278.48 | 278.48 | 20.0 | False | None | None | False | None | False | 5569.6 | 0 | 3547002 | 128185 | None | 2023-24 SR VOL6 3.14.6 (10 of 105) | Supplying and fixing of 6AmpsLamp holder on existing board.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 83.78 | 83.78 | 168.0 | False | None | None | False | None | False | 14075.04 | 0 | 3547003 | 128185 | None | 2023-24 SR VOL6 5.7.3 (14 of 105) | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.63amps.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 473.18 | 473.18 | 63.0 | False | None | None | False | None | False | 29810.34 | 0 | 3547004 | 128185 | None | 2023-24 SR VOL6 5.18.1 (17 of 105) | Supplying and fixing of miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(PWD Electrical SR-II 2023-24) 6-32 Amps SP
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 489.7 | 489.7 | 30.0 | False | None | None | False | None | False | 14691.0 | 0 | 3547005 | 128185 | None | 2023-24 SR VOL6 5.18.4 (17 of 105) | Supplying and fixing of miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(PWD Electrical SR-II 2023-24) 6-32 A DP
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 872.02 | 872.02 | 15.0 | False | None | None | False | None | False | 13080.3 | 0 | 3547006 | 128185 | None | 2023-24 SR VOL6 5.18.8 (17 of 105) | Supplying and fixing of miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.(PWD Electrical SR-II 2023-24) 40 A TPN
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 3591.92 | 3591.92 | 10.0 | False | None | None | False | None | False | 35919.2 | 0 | 3547007 | 128185 | None | 2023-24 SR VOL6 5.17.1 (17 105) | Supplying and fixing regular MCCB distribution panel confirming to IS/IEC 61439-3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with polyurethane (PUR) gasket, with suitable earthing system , on wall / wood/flush mounting required cl A, bolts, nuts, tec., with provision for fixing of suitable type capacity MCCB's as an incomer for three phase Double door with necessary bus bar completely wired to use on 440V 3 phase 4 wire powder coated painting etc., complete with provision for fixing single / three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898-2. 4 way
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 12188.22 | 12188.22 | 4.0 | False | None | None | False | None | False | 48752.88 | 0 | 3547008 | 128185 | None | 2023-24 SR VOL6 5.19.9 (18 of 105) | Supplying and fixing 12 way regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - doble Door 12way sp&n.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 2748.22 | 2748.22 | 6.0 | False | None | None | False | None | False | 16489.32 | 0 | 3547009 | 128185 | None | 2023-24 SR VOL6 6.4.1 (30 of 105) | Supplying of Ceiling Fan with Capacitor rating as per guideline of BEE 5 Star rating and IS: 374/19 and also comply with IS: 1709/1984 with latest ammendement, Rated voltage 220 V / 50 hZ, Rated power upto 35W+/- 10%, Rated current as per IS: 374/19, Rated power factor 0.9 lagging (min), Rated speed 350+/- 10% RPM, Rated air delivery 210+/- 10% Cubic meter Minimum, Rated servive value 6.2 CMM / W, Three blades of blade leaf 1.05 m thick Aluminium alloy sheet, Class B motor insulation, Bearing two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise shall not exceed 75 degree C over and ambient of 40Deg.C by resistance method at 245 V, Insulation resistance shall not be less than Two Mega Ohms (2M Ohms), Leakage current should not exceed 210 Micro Amo, Power input, W & Current, Air Delivery & Fan speed as per IS: 374/2019 with lastest amendement, 2 Years manufacturing Warranty. (BLDC fans). 48 " Sweep 5 Star (1200mm)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 3158.86 | 3158.86 | 35.0 | False | None | None | False | None | False | 110560.1 | 0 | 3547010 | 128185 | None | 2023-24 SR VOL6 6.4.2 (30 of 105) | Supplying of Ceiling Fan with Capacitor rating as per guideline of BEE 5 Star rating and IS: 374/19 and also comply with IS: 1709/1984 with latest ammendement, Rated voltage 220 V / 50 hZ, Rated power upto 35W+/- 10%, Rated current as per IS: 374/19, Rated power factor 0.9 lagging (min), Rated speed 350+/- 10% RPM, Rated air delivery 210+/- 10% Cubic meter Minimum, Rated servive value 6.2 CMM / W, Three blades of blade leaf 1.05 m thick Aluminium alloy sheet, Class B motor insulation, Bearing two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise shall not exceed 75 degree C over and ambient of 40Deg.C by resistance method at 245 V, Insulation resistance shall not be less than Two Mega Ohms (2M Ohms), Leakage current should not exceed 210 Micro Amo, Power input, W & Current, Air Delivery & Fan speed as per IS: 374/2019 with lastest amendement, 2 Years manufacturing Warranty. (BLDC fans). 56 " Sweep 5 Star (1400mm)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 4429.72 | 4429.72 | 10.0 | False | None | None | False | None | False | 44297.2 | 0 | 3547011 | 128185 | None | 2023-24 SR VOL6 11.3.3 (43 of 105) | LED Indood supplying of 1x4 feet LED PVC square batten 36 W with high quality diffuser with life of 25000 burning hours at 70% lumen maintenance with CRI 80 power input 220-240V 50Hz & Power Factor 0.9 along with CE approved drivers. 2 years Warrenty againest any manufacturing defect working under standard electrical condition(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 1497.42 | 1497.42 | 125.0 | False | None | None | False | None | False | 187177.5 | 0 | 3547012 | 128185 | None | 2023-24 SR VOL6 11.11.5 (47 of 105) | Supplying & fixing of retrofi ttype LED bulb. W with OPALacry licdiffuser comprising of LED source with CCT 6500 degreeK, CRI70%. efficacy 80lumenper W, life25000 burning hoursand Compliance to IS10322/IEC60598, LM79&LM80. The LED are driven by HF electronic driver integrated in the system, with PF0.95, power loss should5%of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM79. The operating input voltage should be between 130 to 275V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 Watt , 6500 K
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 317.42 | 317.42 | 43.0 | False | None | None | False | None | False | 13649.06 | 0 | 3547013 | 128185 | None | 2023-24 SR VOL6 13.7.1 (56 of 105) | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 143.96 | 143.96 | 125.0 | False | None | None | False | None | False | 17995.0 | 0 | 3547014 | 128185 | None | 2023-24 SR VOL6 13.10 (57 of 105) | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 201.78 | 201.78 | 45.0 | False | None | None | False | None | False | 9080.1 | 0 | 3547015 | 128185 | None | 2023-24 SR VOL6 12.56 (54 of 105) | Supplying,fixing,wiring,earthelectrodeforgroundingconduits,I.C.cutoutsandotherequipment'sonthemeterboardusing40mmdia2.90mmthickGIpipe2.5mlongburiedinapit.Thepitshouldbefilledwithequalproportionofsaltandcharcoal150mm allround thepipeto complete depth.The connection from the pipe to the conduitetc.,is to be established through GI wire of size as per lSI specification 7.3.3.of IS 732 using 12 mm dia bolts,nuts,washer sand check nuts etc., the pipe shall have 16 through holes of 12 mm dia (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 4141.8 | 4141.8 | 10.0 | False | None | None | False | None | False | 41418.0 | 0 | 3547016 | 128185 | None | 2023-24 SR VOL6 32.07 13 of 81) | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Km | 164667.82 | 164667.82 | 0.12 | False | None | None | False | None | False | 19760.1384 | 0 | 3547017 | 128185 | None | 2023-24 SR VOL6 32.13 (13 of 81) | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip 70 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm) (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Km | 375136.16 | 375136.16 | 0.15 | False | None | None | False | None | False | 56270.424 | 0 | 3547018 | 128185 | None | 2023-24 SR VOL6 21.05 (52 of 81) | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Km | 24645.48 | 24645.48 | 0.12 | False | None | None | False | None | False | 2957.4576 | 0 | 3547019 | 128185 | None | 2023-24 SR VOL6 21.06 (52 of 81) | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 Sqmm (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Km | 36744.02 | 36744.02 | 0.15 | False | None | None | False | None | False | 5511.603 | 0 | 3547020 | 128185 | None | 2023-24 SR VOL6 5.37 (19 of 105) | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Kvar | 566.4 | 566.4 | 15.0 | False | None | None | False | None | False | 8496.0 | 0 | 3547021 | 128185 | None | 2023-24 SR VOL6 5.38 (19 of 105) | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz12/24V D.C (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3547022 | 128185 | None | 2023-24 SR VOL6 5.40.1 (20 of 105) | Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100 A 4 x 30 x 10 mm Aluminium Strips (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 2908.7 | 2908.7 | 3.0 | False | None | None | False | None | False | 8726.1 | 0 | 3547023 | 128185 | None | 2023-24 SR VOL6 5.41.2 (20 of 105) | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50 x 50 x 6 mm (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Mtr | 466.1 | 466.1 | 25.0 | False | None | None | False | None | False | 11652.5 | 0 | 3547024 | 128185 | None | 2023-24 SR VOL6 5.42.1 (21 of 105) | Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.16 SWG ((PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Sq CM | 0.59 | 0.59 | 216200.0 | False | None | None | False | None | False | 127558.0 | 0 | 3547025 | 128185 | None | 2023-24 SR VOL6 5.47 (21 of 105) | Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts
and washers etc.,.) 3-120sec setting.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 2731.7 | 2731.7 | 2.0 | False | None | None | False | None | False | 5463.4 | 0 | 3547026 | 128185 | None | 2023-24 SR VOL6 6.1 (30 of 105) | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 1760.56 | 1760.56 | 6.0 | False | None | None | False | None | False | 10563.36 | 0 | 3547027 | 128185 | None | 2023-24 SR VOL6 11.8.2(46 of 105) | Supply of LED Streetlight luminare with pressure dia cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned.LED Streetlight 40 W (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 4748.32 | 4748.32 | 13.0 | False | None | None | False | None | False | 61728.16 | 0 | 3547028 | 128185 | None | 2023-24 SR VOL6 13.1.1 (56 of 105) | Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket 1x40/2x40 W fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clA, bolts, and nuts and wiring using suitable capacity wires.Using 25mm dia G.I.Pipe(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 1154.04 | 1154.04 | 13.0 | False | None | None | False | None | False | 15002.52 | 0 | 3547029 | 128185 | None | 2023-24 SR VOL6 13.14 (57 of 105) | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 580.56 | 580.56 | 6.0 | False | None | None | False | None | False | 3483.36 | 0 | 3547030 | 128185 | None | 2023-24 SR VOL6 5.12.2(15 of 105) | Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM
Enclosure Sheet Metal Execution)100 A(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 10070.12 | 10070.12 | 3.0 | False | None | None | False | None | False | 30210.36 | 0 | 3547031 | 128185 | None | 2023-24 SR VOL6 5.14.3(16 of 105) | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.40 A (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 7220.42 | 7220.42 | 2.0 | False | None | None | False | None | False | 14440.84 | 0 | 3547032 | 128185 | None | 2023-24 SR VOL6 5.15.9(17 of 105) | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,
bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal
Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles
should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and
Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front
cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover
open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR Pole.100A 25 kA (PWD Electrical SR-II 2023-24)"
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 10014.66 | 10014.66 | 4.0 | False | None | None | False | None | False | 40058.64 | 0 | 3547033 | 128185 | None | 2023-24 SR VOL6 5.20.1(18 of 105) | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16A-25A 2 pole (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 5046.86 | 5046.86 | 6.0 | False | None | None | False | None | False | 30281.16 | 0 | 3547034 | 128185 | None | 2023-24 SR VOL6 5.21(18 of 105) | Supplying,fixingandwiringearthleakagerelaywithcorebalancedcurrenttransformersuitableforsinglephase50HzACwithlatestmicrocontrollerbased,digitalreadoutofpercentageleakagecurrent,programmabledelay/auto/manualresetfacilitysuitabletomountonDIN rail/ flush mounting on panel board.(PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 10920.9 | 10920.9 | 3.0 | False | None | None | False | None | False | 32762.7 | 0 | 3547035 | 128185 | None | 2023-24 SR VOL6 5.22 (18 of 105) | Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. pole (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 533.36 | 533.36 | 3.0 | False | None | None | False | None | False | 1600.08 | 0 | 3547036 | 128185 | None | 2023-24 SR VOL6 5.24 (18 of 105) | Supplying, fixing and wiring 0 to 30A Direct Reading AC analog type Ammeter (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 548.7 | 548.7 | 3.0 | False | None | None | False | None | False | 1646.1 | 0 | 3547037 | 128185 | None | 2023-24 SR VOL6 5.26 (18 of 105) | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CT (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 566.4 | 566.4 | 1.0 | False | None | None | False | None | False | 566.4 | 0 | 3547038 | 128185 | None | 2023-24 SR VOL6 5.29 (19 of 105) | Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter (PWD Electrical SR-II 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 1681.5 | 1681.5 | 3.0 | False | None | None | False | None | False | 5044.5 | 0 | 3547039 | 128185 | None | 2023-24 SR VOL6 5.31 (19 of 105) | Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in
polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired.(PWD Electrical SR-II 2023-24)"
---- Work should be carried out as per the direction of engineer incharge of work. | Nos | 5180.2 | 5180.2 | 1.0 | False | None | None | False | None | False | 5180.2 | 0 | 3547040 | 128185 | None | 2023-24 SR VOL6 5.33(19 of 105) | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power,
power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired
as required with communication Port and Class 0.5s accuracy (PWD Electrical SR-II 2023-24)"
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 10991.7 | 10991.7 | 1.0 | False | None | None | False | None | False | 10991.7 | 0 | 3547041 | 128185 | None | 2023-24 SR VOL5 Item 11.1.7 Pg No127 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete Light Duty GI pipe of 65mm dia (Volume - 5 SR Water Supply and Sewerage Works)
---- Work should be carried out as per the direction of engineer incharge of work. | Rmtr | 788.24 | 788.24 | 200.0 | False | None | None | False | None | False | 157648.0 | 0 | 3547042 | 128185 | None | 2023-24 SR VOL5 Item 11.1.5 Pg No127 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete Light Duty GI pipe of 40mm dia (Volume - 5 SR Water Supply and Sewerage Works)
---- Work should be carried out as per the direction of engineer incharge of work. | Rmtr | 486.16 | 486.16 | 30.0 | False | None | None | False | None | False | 14584.8 | 0 | 3547043 | 128185 | None | 2023-24 SR VOL1 Item1.4.1 Pg No5 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.( PWD common SR Vol-I 2023-24)"
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 285.56 | 285.56 | 45.0 | False | None | None | False | None | False | 12850.2 | 0 | 3547044 | 128185 | None | 2023-24 SR VOL1 Item1.10 Pg No7 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications ( PWD common SR Vol-I 2023-24)
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 188.8 | 188.8 | 45.0 | False | None | None | False | None | False | 8496.0 | 0 | 3547045 | 128185 | None | 2023-24 SR VOL6 Item10.1.6 Pg No42 | Providing and commissioning 50Kva/40 Kw Generator
Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications.50KVA/40kw
---- Work should be carried out as per the direction of engineer incharge of work. | Set | 728494.24 | 728494.24 | 1.0 | False | None | None | False | None | False | 728494.24 | 0 | 3547046 | 128185 | None | 2023-24 SR VOL6 Item32.08 Pg No13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC extruded Inner Seath Armoured LTUG Cable as per IS-1554 (part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 25 Sqmm 4 core (13 GI strips-4x0.8 mm) (ESCOM P.No. 13 of 81)
---- Work should be carried out as per the direction of engineer incharge of work. | Km | 212215.92 | 212215.92 | 0.2 | False | None | None | False | None | False | 42443.184 | 0 | 3547047 | 128185 | None | 2023-24 SR VOL6 Item63.01Pg No28 | Brass cable gland 25 mm (ESCOM P.no. 28 of 81)
---- Work should be carried out as per the direction of engineer incharge of work. | No | 93.22 | 93.22 | 8.0 | False | None | None | False | None | False | 745.76 | 0 | 3547048 | 128185 | None | 2023-24 SR VOL6 Item21.05 Pg No52 | Laying of Cable in Existing Trench/GI pipe/Stone Warw/RCC Hume pipe using Wooden/ Aluminium Rollers as directed by the department staff. LT Cable 2.5 to 25 Sqmm
---- Work should be carried out as per the direction of engineer incharge of work. | Km | 24645.48 | 24645.48 | 0.2 | False | None | None | False | None | False | 4929.096 | 0 | 3547049 | 128185 | None | 2023-24 SR VOL6 Item66.04 Pg No30 | HDPE/PLB Pipe 50/42 mm
---- Work should be carried out as per the direction of engineer incharge of work. | Km | 100316.52 | 100316.52 | 0.2 | False | None | None | False | None | False | 20063.304 | 0 | 3547050 | 128185 | None | 2023-24 SR VOL6 Item6.8.5 Pg No31 | Providing Air conditioners
Supplying of . TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The
condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 star 1.5 Ton capacity
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 66498.9 | 66498.9 | 5.0 | False | None | None | False | None | False | 332494.5 | 0 | 3547051 | 128185 | None | 2023-24 SR VOL6 Item6.8.6 Pg No31 | Supplying of . TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The
condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 star 2 Ton capacity
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 79530.82 | 79530.82 | 3.0 | False | None | None | False | None | False | 238592.46 | 0 | 3547052 | 128185 | None | 2023-24 SR VOL6 Item6.12 Pg No32 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 3746.5 | 3746.5 | 8.0 | False | None | None | False | None | False | 29972.0 | 0 | 3547053 | 128185 | None | 2023-24 SR VOL6 Item6.22 Pg No32 | Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 5672.26 | 5672.26 | 8.0 | False | None | None | False | None | False | 45378.08 | 0 | 3547054 | 128185 | None | 2023-24 SR VOL6 Item9.1.3 Pg No38 | Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete 5 kVA Capacity
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 11405.88 | 11405.88 | 8.0 | False | None | None | False | None | False | 91247.04 | 0 | 3547055 | 128185 | None | 2023-24 SR VOL6 Item6.13.1 Pg No32 | Supplying and installation of insulated refrigarant copper tubing of 5/8" and 3/8" with polythen foam insulation 3 core 80 strand copper wiring between indoor and out door unit Leak testing oil and gas charging for additional piping length of tube. Split
---- Work should be carried out as per the direction of engineer incharge of work. | m | 1827.82 | 1827.82 | 40.0 | False | None | None | False | None | False | 73112.8 | 0 | 3547056 | 128185 | None | 2023-24 SR VOL6 Item Code9.2.4 Page No38 | UPS and LAN work
Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete 3 kVA OFF LINE UPS
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 34387.56 | 34387.56 | 2.0 | False | None | None | False | None | False | 68775.12 | 0 | 3547057 | 128185 | None | 2023-24 SR VOL6Item Code9.2.5 Page No38 | Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete 5 kVA OFF LINE UPS
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 47079.64 | 47079.64 | 1.0 | False | None | None | False | None | False | 47079.64 | 0 | 3547058 | 128185 | None | 2023-24 SR VOL6Item Code9.4.6Page No38 | Supplying, installation, testing & commissioning of 12V .AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type 150 AH capacity
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 33260.66 | 33260.66 | 12.0 | False | None | None | False | None | False | 399127.92 | 0 | 3547059 | 128185 | None | 2023-24 SR VOL6Item Code8.1Page No36 | Supplying and drawing UTP-CAT 6E LAN cable
---- Work should be carried out as per the direction of engineer incharge of work. | m | 44.84 | 44.84 | 1500.0 | False | None | None | False | None | False | 67260.0 | 0 | 3547060 | 128185 | None | 2023-24 SR VOL6Item Code8.4.2Page No36 | Supplying & Fixing of switch mounting rack with power manager & Cable manager. 6U with 450mm dept
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 8232.86 | 8232.86 | 2.0 | False | None | None | False | None | False | 16465.72 | 0 | 3547061 | 128185 | None | 2023-24 SR VOL6Item Code8.5Page No36 | Supplying & Fixing of Power strip
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 1719.26 | 1719.26 | 2.0 | False | None | None | False | None | False | 3438.52 | 0 | 3547062 | 128185 | None | 2023-24 SR VOL6Item Code8.8Page No36 | Supplying & Fixing of Fan
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 1426.62 | 1426.62 | 2.0 | False | None | None | False | None | False | 2853.24 | 0 | 3547063 | 128185 | None | 2023-24 SR VOL6Item Code8.9.3Page No36 | Supplying fixing of Network Switches
10Port Gigabyte (manageable)
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 23836.0 | 23836.0 | 2.0 | False | None | None | False | None | False | 47672.0 | 0 | 3547064 | 128185 | None | 2023-24 SR VOL6Item Code8.9.11Page No36 | 16 port 10/100/1000 Switch
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 7599.2 | 7599.2 | 2.0 | False | None | None | False | None | False | 15198.4 | 0 | 3547065 | 128185 | None | 2023-24 SR VOL6Item Code8.10.2Page No37 | Supplying & fixing of I/O socket with back box
Double I/O "
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 649.0 | 649.0 | 35.0 | False | None | None | False | None | False | 22715.0 | 0 | 3547066 | 128185 | None | 2023-24 SR VOL6Item Code8.11.1Page No37 | Supplying & Fixing of . ms Cat 6 Patch Cable
1m"
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 264.32 | 264.32 | 35.0 | False | None | None | False | None | False | 9251.2 | 0 | 3547067 | 128185 | None | 2023-24 SR VOL6Item Code8.12.6Page No37 | Supplying & Fixing of Patch panel for LAN cabling
16 Port 10/100 patch panel"
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 9145.0 | 9145.0 | 2.0 | False | None | None | False | None | False | 18290.0 | 0 | 3547068 | 128185 | None | 2023-24 SR VOL6 item 4.4.5 Pg No12 | Street lighting out side
Fabricating, supplying and erection of . ms long hot dip Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for .m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom . mm , top . mmwith 3 mm thick, suitable base plate and 4Nos of.long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended.7 m - Top 75 mm and Bottom 145 mm dia, (PWD Electrical SR 2023-24, Pg No: 12/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 17700.0 | 17700.0 | 20.0 | False | None | None | False | None | False | 354000.0 | 0 | 3547069 | 128185 | None | 2023-24 SR VOL6 item 4.6.4 Pg No13 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.Single Arm Bracket with 1000 mm Standard 40/50 mm dia (PWD Electrical SR 2023-24, Pg No: 13/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 3186.0 | 3186.0 | 12.0 | False | None | None | False | None | False | 38232.0 | 0 | 3547070 | 128185 | None | 2023-24 SR VOL6 item 4.6.5 Pg No13 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.Double Arm Bracket with 1500 mm Standard 40/50 mm dia (PWD Electrical SR 2023-24, Pg No: 13/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 3894.0 | 3894.0 | 4.0 | False | None | None | False | None | False | 15576.0 | 0 | 3547071 | 128185 | None | 2023-24 SR VOL6 item 11.8.5Pg No46 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit miss-wiring protection.
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 11870.8 | 11870.8 | 28.0 | False | None | None | False | None | False | 332382.4 | 0 | 3547072 | 128185 | None | 2023-24 SR VOL6 item 13.5Pg No56 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires (PWD Electrical SR 2023-24, Pg No: 56/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 191.16 | 191.16 | 28.0 | False | None | None | False | None | False | 5352.48 | 0 | 3547073 | 128185 | None | 2023-24 SR VOL6 item 5.13.1Pg No15 | Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.25 A (PWD Electrical SR 2023-24, Pg No: 15/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 1522.2 | 1522.2 | 1.0 | False | None | None | False | None | False | 1522.2 | 0 | 3547074 | 128185 | None | 2023-24 SR VOL6 item 5.18.8Pg No17 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.40 A TPN (PWD Electrical SR 2023-24, Pg No: 17/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 3591.92 | 3591.92 | 2.0 | False | None | None | False | None | False | 7183.84 | 0 | 3547075 | 128185 | None | 2023-24 SR VOL6 item 5.22Pg No18 | Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. (PWD Electrical SR 2023-24, Pg No: 18/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 533.36 | 533.36 | 1.0 | False | None | None | False | None | False | 533.36 | 0 | 3547076 | 128185 | None | 2023-24 SR VOL6 item 5.24Pg No18 | Supplying, fixing and wiring 0 to 30A Direct Reading AC analog type Ammeter (PWD Electrical SR 2023-24, Pg No: 18/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 548.7 | 548.7 | 1.0 | False | None | None | False | None | False | 548.7 | 0 | 3547077 | 128185 | None | 2023-24 SR VOL6 item 5.27Pg No19 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter (PWD Electrical SR 2023-24, Pg No: 19/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 | 3547078 | 128185 | None | 2023-24 SR VOL6 item 5.28Pg No19 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter (PWD Electrical SR 2023-24, Pg No: 19/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 188.8 | 188.8 | 1.0 | False | None | None | False | None | False | 188.8 | 0 | 3547079 | 128185 | None | 2023-24 SR VOL6 item 5.29Pg No19 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. (PWD Electrical SR 2023-24, Pg No: 19/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3547080 | 128185 | None | 2023-24 SR VOL6 item 5.41.2Pg No20 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and paintedwith 2 coats of red oxide and then two coats of approved paint. 50 x 50 x 6 mm (PWD Electrical SR 2023-24, Pg No: 20/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | m | 466.1 | 466.1 | 10.0 | False | None | None | False | None | False | 4661.0 | 0 | 3547081 | 128185 | None | 2023-24 SR VOL6 item 5.41.1Pg No20 | Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable
size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paintand finally finished with approved colour etc., complete 14 SWG (PWD Electrical SR 2023-24, Pg No: 20/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | Sq CM | 0.59 | 0.59 | 50000.0 | False | None | None | False | None | False | 29500.0 | 0 | 3547082 | 128185 | None | 2023-24 SR VOL6 item 5.47Pg No21 | Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting (PWD Electrical SR 2023-24, Pg No: 21/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | Each | 2731.7 | 2731.7 | 1.0 | False | None | None | False | None | False | 2731.7 | 0 | 3547083 | 128185 | None | 2023-24 SR VOL6 item 32.05Pg No13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm
---- Work should be carried out as per the direction of engineer incharge of work. | Km | 167373.56 | 167373.56 | 0.7 | False | None | None | False | None | False | 117161.492 | 0 | 3547084 | 128185 | None | 2023-24 SR VOL6 item302.08Pg No13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath
Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip
thickness and resistivity as per IS-3975 25 Sqmm, 4 Core, (13 GI Strips - 4 x 0.8 mm) (PWD Electrical SR 2023-24, Pg No: 13/81 )
---- Work should be carried out as per the direction of engineer incharge of work. | Km | 212215.92 | 212215.92 | 0.06 | False | None | None | False | None | False | 12732.9552 | 0 | 3547085 | 128185 | None | 2023-24 SR VOL6 item 12.56Pg No54 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia (PWD Electrical SR 2023-24, Pg No: 54/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | No | 4141.8 | 4141.8 | 2.0 | False | None | None | False | None | False | 8283.6 | 0 | 3547086 | 128185 | None | 2023-24 SR VOL6 item 12.58.2Pg No54 | GI/Copper strips for grounding connections, using necessary fixing
materials as required. 25 x 3 mm GI strip (PWD Electrical SR 2023-24, Pg No: 54/105 )
---- Work should be carried out as per the direction of engineer incharge of work. | m | 96.76 | 96.76 | 10.0 | False | None | None | False | None | False | 967.6 | 0 | 3547087 | 128185 | None | 2023-24 SR VOL6 item 66.04Pg No30 | HDPE/PLB Pipe 50/42 mm (PWD Electrical SR 2023-24, Pg No: 30/81 )
---- Work should be carried out as per the direction of engineer incharge of work. | Km | 100316.52 | 100316.52 | 0.03 | False | None | None | False | None | False | 3009.4956 | 0 | 3547088 | 128185 | None | 2023-24 SR VOL6 item 66.05Pg No30 | HDPE/PLB Pipe 40/33 mm (PWD Electrical SR 2023-24, Pg No: 30/81 )
---- Work should be carried out as per the direction of engineer incharge of work. | Km | 73556.48 | 73556.48 | 0.7 | False | None | None | False | None | False | 51489.536 | 0 | 3547089 | 128185 | None | 2023-24 SR VOL1 item 1.4.1Pg No5 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (PWD Common SR 2023-24 Vol-I, Pg No:5)
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 285.56 | 285.56 | 270.81 | False | None | None | False | None | False | 77332.5036 | 0 | 3547090 | 128185 | None | 2023-24 SR VOL6 item 2.1.2Pg No15 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD Common SR 2023-24 Vol-I, Pg No:15)
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 6683.52 | 6683.52 | 1.3 | False | None | None | False | None | False | 8688.576 | 0 | 3547091 | 128185 | None | 2023-24 SR VOL1 item 2.2.1Pg No15 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD Common SR 2023-24 Vol-I, Pg No:15) RCC
---- Work should be carried out as per the direction of engineer incharge of work. | Cum | 7418.66 | 7418.66 | 13.5 | False | None | None | False | None | False | 100151.91 | 0 | 3547092 | 128185 | None | 2023-24 SR VOL6 item 2.11.hPg No18 | Steel fabrication: Supplying , fitting and placing TMT FE 550 / 550 D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping / welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.
---- Work should be carried out as per the direction of engineer incharge of work. | t | 93232.98 | 93232.98 | 0.156 | False | None | None | False | None | False | 14544.34488 | 0 |
|
|
---|