createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1722239550158
version15
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1900.00
emd114000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-08-2024 16:00:00
tenderQueryClose05-08-2024 16:00:00
technicalBidOpen14-08-2024 16:00:00
publishedDate29-07-2024 14:00:41
publishedByPostKHB_EE2_CO_BNG
publishedByUserKPE11678 - LOKESHBABU C G
bidValidityPeriod180
noOfCalls3
preBidMeetingDate06-08-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonLokesh Babu C G
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1722239550161
version23
createdDateNone
modifiedDateNone
tenderNumberKHB/2023-24/BD/WORK_INDENT81/CALL-3
titleConstruction of class rooms for Government Polytechnic college at Lingasaguru in Raichuru District under SDP 2022-23 Scheme
descriptionConstruction of class rooms for Government Polytechnic college at Lingasaguru in Raichuru District under SDP 2022-23 Scheme
categoryWORKS
categoryTextWorks
ecv7577009.11
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount7577010.0
groupOverheadTotalNone
fileNumber40/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17222395500001NoneNoneBuildingsConstruction of class rooms for Government Polytechnic college at Lingasaguru in Raichuru District under SDP 2022-23 Scheme7577009.11
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3637934132391Nonecode01Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-chargeCum1337.71337.77.56FalseNoneNoneFalseNoneFalse10113.0120
3637935132391Nonecode02Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortarCum828.45828.4514.93FalseNoneNoneFalseNoneFalse12368.75850
3637936132391Nonecode03Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeSqm58.858.8350.4FalseNoneNoneFalseNoneFalse20603.520
3637937132391Nonecode04Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-chargeSqm30.4530.45188.4FalseNoneNoneFalseNoneFalse5736.780
3637938132391Nonecode05Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specificationsSqm15.7515.75188.0FalseNoneNoneFalseNoneFalse2961.00
3637939132391Nonecode06Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM)Cum11152.4311152.4327.3044FalseNoneNoneFalseNoneFalse304510.4096920
3637940132391Nonecode07Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM)Cum10326.7210326.727.92FalseNoneNoneFalseNoneFalse81787.62240
3637941132391Nonecode08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM)Cum10496.410496.441.26FalseNoneNoneFalseNoneFalse433081.4640
3637942132391Nonecode09Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM)Cum10496.410496.44.0FalseNoneNoneFalseNoneFalse41985.60
3637943132391Nonecode10Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates(60% shuttering charge)Cum9719.279719.274.0FalseNoneNoneFalseNoneFalse38877.080
3637944132391Nonecode11Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specificationsSqm1268.361268.36598.92FalseNoneNoneFalseNoneFalse759646.17120
3637945132391Nonecode12Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm996.87996.87157.68FalseNoneNoneFalseNoneFalse157186.46160
3637946132391Nonecode13Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM)Cum9840.389840.3867.88FalseNoneNoneFalseNoneFalse667964.99440
3637947132391Nonecode14Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9512.379512.378.7FalseNoneNoneFalseNoneFalse82757.6190
3637948132391Nonecode15Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Kg96.696.622877.82FalseNoneNoneFalseNoneFalse2209997.4120
3637949132391Nonecode16Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum65329.9865329.980.37FalseNoneNoneFalseNoneFalse24172.09260
3637950132391Nonecode17Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum65976.8165976.810.07FalseNoneNoneFalseNoneFalse4618.37670
3637951132391Nonecode18Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with Gi reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7128.687128.6857.6FalseNoneNoneFalseNoneFalse410611.9680
3637952132391Nonecode19Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-35 mm thick both side commercialSqm3122.113122.1112.6FalseNoneNoneFalseNoneFalse39338.5860
3637953132391Nonecode20Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg152.25152.251036.8FalseNoneNoneFalseNoneFalse157852.80
3637954132391Nonecode21Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg155.3155.3103.68FalseNoneNoneFalseNoneFalse16101.5040
3637955132391Nonecode22Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.No114.45114.456.0FalseNoneNoneFalseNoneFalse686.70
3637956132391Nonecode23Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.No873.6873.66.0FalseNoneNoneFalseNoneFalse5241.60
3637957132391Nonecode24Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete.No183.75183.7510.0FalseNoneNoneFalseNoneFalse1837.50
3637958132391Nonecode25Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete.No116.55116.5516.0FalseNoneNoneFalseNoneFalse1864.80
3637959132391Nonecode26Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc.-125x65x2.12mm.No39.939.922.0FalseNoneNoneFalseNoneFalse877.80
3637960132391Nonecode27Providing and fixing MS Hold fastsNo33.633.622.0FalseNoneNoneFalseNoneFalse739.20
3637961132391Nonecode28Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing completeSqm290.58290.58399.72FalseNoneNoneFalseNoneFalse116150.63760
3637962132391Nonecode29Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm329.82329.82687.57FalseNoneNoneFalseNoneFalse226774.33740
3637963132391Nonecode30Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm341.48341.48690.41FalseNoneNoneFalseNoneFalse235761.20680
3637964132391Nonecode31Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6134.696134.6929.09FalseNoneNoneFalseNoneFalse178458.13210
3637965132391Nonecode32Providing 12 mm cement plaster with Cement mortar 1:3 (1cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing completeSqm293.45293.45387.88FalseNoneNoneFalseNoneFalse113823.3860
3637966132391Nonecode33Providing and laying flamed finised Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.Sqm2002.222002.2295.16FalseNoneNoneFalseNoneFalse190531.25520
3637967132391Nonecode34Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile (600X600) mmSqm1152.761152.76319.52FalseNoneNoneFalseNoneFalse368329.87520
3637968132391Nonecode35Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm88.0288.021087.29FalseNoneNoneFalseNoneFalse95703.26580
3637969132391Nonecode36Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm125.14125.141087.29FalseNoneNoneFalseNoneFalse136063.47060
3637970132391Nonecode37Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm126.39126.39687.57FalseNoneNoneFalseNoneFalse86901.97230
3637971132391Nonecode38Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.-First FloorSqm144.23144.23690.41FalseNoneNoneFalseNoneFalse99577.83430
3637972132391Nonecode39Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge SECOND FLOORSqm147.11147.11172.6FalseNoneNoneFalseNoneFalse25391.1860
3637973132391Nonecode40Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm112.41112.4169.12FalseNoneNoneFalseNoneFalse7769.77920
3637974132391Nonecode41Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm110.25110.2532.76FalseNoneNoneFalseNoneFalse3611.790
3637975132391Nonecode42Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 110mm dia., 6 kg/sqcm & class 3m417.84417.8482.8FalseNoneNoneFalseNoneFalse34597.1520
3637976132391Nonecode43Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet-Short point upto 3 mtr from tapping point to outlet via switch.Point251.0251.010.0FalseNoneNoneFalseNoneFalse2510.00
3637977132391Nonecode44Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet- Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint361.0361.016.0FalseNoneNoneFalseNoneFalse5776.00
3637978132391Nonecode45Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet- Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint542.0542.018.0FalseNoneNoneFalseNoneFalse9756.00
3637979132391Nonecode46Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switchesPoint671.0671.016.0FalseNoneNoneFalseNoneFalse10736.00
3637980132391Nonecode47Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switchesPoint979.0979.018.0FalseNoneNoneFalseNoneFalse17622.00
3637981132391Nonecode48Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-1-3wayEach123.0123.06.0FalseNoneNoneFalseNoneFalse738.00
3637982132391Nonecode49Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5WayEach138.0138.08.0FalseNoneNoneFalseNoneFalse1104.00
3637983132391Nonecode50Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayEach212.0212.08.0FalseNoneNoneFalseNoneFalse1696.00
3637984132391Nonecode51Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 WayEach250.0250.05.0FalseNoneNoneFalseNoneFalse1250.00
3637985132391Nonecode52Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-1to3 moduleEach152.0152.06.0FalseNoneNoneFalseNoneFalse912.00
3637986132391Nonecode53Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 4 ModuleEach175.0175.08.0FalseNoneNoneFalseNoneFalse1400.00
3637987132391Nonecode54Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 ModuleEach244.0244.08.0FalseNoneNoneFalseNoneFalse1952.00
3637988132391Nonecode55Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 8 ModuleEach302.0302.05.0FalseNoneNoneFalseNoneFalse1510.00
3637989132391Nonecode56Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and I-6 Amps one way switchS 1293.Each88.088.012.0FalseNoneNoneFalseNoneFalse1056.00
3637990132391Nonecode57Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 6Amps Two way SwitchEach152.0152.04.0FalseNoneNoneFalseNoneFalse608.00
3637991132391Nonecode58Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 6Amps 3way socketEach162.0162.06.0FalseNoneNoneFalseNoneFalse972.00
3637992132391Nonecode59Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 Stepped Fan Regulator.Each313.0313.08.0FalseNoneNoneFalseNoneFalse2504.00
3637993132391Nonecode60Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 16Amps one way switchEach249.0249.04.0FalseNoneNoneFalseNoneFalse996.00
3637994132391Nonecode61Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 32Amps DP switchEach375.0375.02.0FalseNoneNoneFalseNoneFalse750.00
3637995132391Nonecode62Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 6/16Amps universal socketEach249.0249.04.0FalseNoneNoneFalseNoneFalse996.00
3637996132391Nonecode63Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely.-SP&N-20AEach873.0873.02.0FalseNoneNoneFalseNoneFalse1746.00
3637997132391Nonecode64Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. TP & N-30AEach1534.01534.02.0FalseNoneNoneFalseNoneFalse3068.00
3637998132391Nonecode65Supplying and fixing of MODULAR MCB Devices(Tripper) With Breaking capacity of 6KA. -16-32A SPEach190.0190.02.0FalseNoneNoneFalseNoneFalse380.00
3637999132391Nonecode66Supplying and fixing of MODULAR MCB Devices(Tripper) With Breaking capacity of 6KA. 16 - 32 A TPEach721.0721.02.0FalseNoneNoneFalseNoneFalse1442.00
3638000132391Nonecode67Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2)-19/20mm dia 2mm thickm61.061.045.0FalseNoneNoneFalseNoneFalse2745.00
3638001132391Nonecode68Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thickm70.070.036.0FalseNoneNoneFalseNoneFalse2520.00
3638002132391Nonecode69Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thickm93.093.026.0FalseNoneNoneFalseNoneFalse2418.00
3638003132391Nonecode70Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary.-19/20mm dia 2 mm thickm75.075.045.0FalseNoneNoneFalseNoneFalse3375.00
3638004132391Nonecode71Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary 25mm dia 2mm thickm80.080.022.0FalseNoneNoneFalseNoneFalse1760.00
3638005132391Nonecode72Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary 32mm dia 2.5mm thickm105.0105.016.0FalseNoneNoneFalseNoneFalse1680.00
3638006132391Nonecode73Supplying and fixing PVC/metal conduit Deep junction box-25mm deep junction boxNo51.051.010.0FalseNoneNoneFalseNoneFalse510.00
3638007132391Nonecode74Supplying and fixing PVC/metal conduit Deep junction box 32 mm deep junction boxNo69.069.05.0FalseNoneNoneFalseNoneFalse345.00
3638008132391Nonecode75Supplying And Fixing Metal Fan Box with Round Hook.No163.0163.08.0FalseNoneNoneFalseNoneFalse1304.00
3638009132391Nonecode76Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments-1 sqmm.m18.018.016.0FalseNoneNoneFalseNoneFalse288.00
3638010132391Nonecode77Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5 sqmmm26.026.018.0FalseNoneNoneFalseNoneFalse468.00
3638011132391Nonecode78Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.5 sqmmm40.040.032.0FalseNoneNoneFalseNoneFalse1280.00
3638012132391Nonecode79Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 4 sqmmm59.059.028.0FalseNoneNoneFalseNoneFalse1652.00
3638013132391Nonecode80Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 6 sqmmm87.087.056.0FalseNoneNoneFalseNoneFalse4872.00
3638014132391Nonecode81Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED light fitting 1x4"-20/22wEach740.0740.024.0FalseNoneNoneFalseNoneFalse17760.00
3638015132391Nonecode82Supplying & Fixing of 70-150 Watts lamp holder 2 PinNo118.0118.04.0FalseNoneNoneFalseNoneFalse472.00
3638016132391Nonecode83Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.-12"sweep(300mm)Each2997.02997.01.0FalseNoneNoneFalseNoneFalse2997.00
3638017132391Nonecode84Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.-48"sweep(1200mm)Regular modelEach2085.02085.016.0FalseNoneNoneFalseNoneFalse33360.00
3638018132391Nonecode85Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply.-400mm sweepEach2838.02838.02.0FalseNoneNoneFalseNoneFalse5676.00
3638019132391Nonecode86Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.-on wall/ceiling/rafters/girdersEach119.0119.04.0FalseNoneNoneFalseNoneFalse476.00
3638020132391Nonecode87Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each162.0162.02.0FalseNoneNoneFalseNoneFalse324.00
3638021132391Nonecode88Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.-using 32mm dia GI pipeEach1136.01136.01.0FalseNoneNoneFalseNoneFalse1136.00
3638022132391Nonecode89Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each189.0189.01.0FalseNoneNoneFalseNoneFalse189.00
3638023132391Nonecode90Supplying and fixing regular MCB distribution boards on wall wood board I flush mounting using required clamps, i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure-Double door-4 way SP&NEach1100.01100.01.0FalseNoneNoneFalseNoneFalse1100.00
3638024132391Nonecode91Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6-32Amps SPEach434.0434.02.0FalseNoneNoneFalseNoneFalse868.00
3638025132391Nonecode92Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6 6-32 Amps DPEach909.0909.01.0FalseNoneNoneFalseNoneFalse909.00
3638026132391Nonecode93Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts,nuts and washers etc.,.) 3-120sec settingEach2079.02079.01.0FalseNoneNoneFalseNoneFalse2079.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17222395500000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17222395500000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17222395500000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17222395500000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17222395500000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17222395500000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17222395500000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17222395500000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17222395500000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17222395500000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17222395500000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17222395500000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17222395500000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17222395500000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17222395500000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17222395500000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17222395500000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1722241086000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone