createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1722335265818
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd3203000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose30-08-2024 16:00:00
tenderQueryClose19-08-2024 16:00:00
technicalBidOpen31-08-2024 16:30:00
publishedDate30-07-2024 18:20:06
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate20-08-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonTechnical Assistant
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9448653156
tenderSupplierListNone
tenderSchedule
createdTs1722335265845
version7
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2024-25/BD/WORK_INDENT548
titleConstruction of 100 Bedded Taluk Level Hospital at Shirahatti in Gadag District
descriptionConstruction of 100 Bedded Taluk Level Hospital at Shirahatti in Gadag District
categoryWORKS
categoryTextWorks
ecv320251948.75
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount372000000.0
groupOverheadTotal0.0
fileNumberhfw/eng/subdvn/dwd/2023-24TLH37
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17223352660000NoneNoneBuildingsTLH SHIRAHATTI CIVIL FF39095316.71
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3646446132942NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:COLUMNS-70% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum14280.2514280.25120.771FalseNoneNoneFalseNoneFalse1724640.072750
3646447132942NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:RCC BEAMS-60% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13440.2413440.24194.63FalseNoneNoneFalseNoneFalse2615873.91120
3646448132942NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:RCC SLAB-50% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12600.2212600.22295.581FalseNoneNoneFalseNoneFalse3724385.627820
3646449132942NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:FIRST FLOOR STAIRCASE-50% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12600.2212600.2216.79FalseNoneNoneFalseNoneFalse211557.69380
3646450132942NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:LINTELS-60% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13440.2413440.2421.6152FalseNoneNoneFalseNoneFalse290513.4756480
3646451132942NoneItem 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11801.0911801.0917.795FalseNoneNoneFalseNoneFalse210000.396550
3646452132942NoneItem 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget109813.29109813.2996.759FalseNoneNoneFalseNoneFalse10625424.127110
3646453132942NoneItem 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1608.091608.092261.061FalseNoneNoneFalseNoneFalse3635989.583490
3646454132942NoneItem 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1355.211355.21316.967FalseNoneNoneFalseNoneFalse429556.848070
3646455132942NoneItem 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum121300.74121300.742.28FalseNoneNoneFalseNoneFalse276565.68720
3646456132942NoneItem 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1247.191247.1937.0FalseNoneNoneFalseNoneFalse46146.030
3646457132942NoneItem 22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo675.15675.1574.0FalseNoneNoneFalseNoneFalse49961.10
3646458132942NoneItem 22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo460.33460.3315.0FalseNoneNoneFalseNoneFalse6904.950
3646459132942NoneItem 22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo184.13184.1374.0FalseNoneNoneFalseNoneFalse13625.620
3646460132942NoneItem 22.15.9Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo85.9285.92111.0FalseNoneNoneFalseNoneFalse9537.120
3646461132942NoneItem 22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo122.75122.7537.0FalseNoneNoneFalseNoneFalse4541.750
3646462132942NoneItem 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1291.381291.3837.0FalseNoneNoneFalseNoneFalse47781.060
3646463132942NoneItem 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos73.6573.65222.0FalseNoneNoneFalseNoneFalse16350.30
3646464132942NoneItem 20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr63.8363.83191.25FalseNoneNoneFalseNoneFalse12207.48750
3646465132942NoneItem 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4077.934077.9399.96FalseNoneNoneFalseNoneFalse407629.88280
3646466132942NoneItem 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm8266.38266.375.6FalseNoneNoneFalseNoneFalse624932.280
3646467132942NoneItem 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm7020.387020.3818.9FalseNoneNoneFalseNoneFalse132685.1820
3646468132942NoneItem 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg206.22206.221984.5FalseNoneNoneFalseNoneFalse409243.590
3646469132942NoneItem 12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1367.491367.4937.0FalseNoneNoneFalseNoneFalse50597.130
3646470132942NoneItem 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem861.74861.74134.8FalseNoneNoneFalseNoneFalse116162.5520
3646471132942NoneItem 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4278.024278.0247.04FalseNoneNoneFalseNoneFalse201238.06080
3646472132942NoneItem 12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm7666.077666.0712.96FalseNoneNoneFalseNoneFalse99352.26720
3646473132942NoneItem 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm382.99382.993350.76FalseNoneNoneFalseNoneFalse1283307.57240
3646474132942NoneItem 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm259.01259.013011.62FalseNoneNoneFalseNoneFalse780039.69620
3646475132942NoneItem 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm101.88101.886362.38FalseNoneNoneFalseNoneFalse648199.27440
3646476132942NoneItem 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm428.41428.411232.95FalseNoneNoneFalseNoneFalse528208.10950
3646477132942NoneItem 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm434.55434.5591.85FalseNoneNoneFalseNoneFalse39913.41750
3646478132942NoneItem 8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr46.6446.646608.82FalseNoneNoneFalseNoneFalse308235.36480
3646479132942NoneItem 7.18Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum2475.972475.9729.5476FalseNoneNoneFalseNoneFalse73158.9711720
3646480132942NoneItem 15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm754.94754.94176.047FalseNoneNoneFalseNoneFalse132904.922180
3646481132942NoneItem 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr63.8363.831088.19FalseNoneNoneFalseNoneFalse69459.16770
3646482132942NoneItem 9.17.2Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1442.371442.371092.7FalseNoneNoneFalseNoneFalse1576077.6990
3646483132942NoneItem 9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1627.731627.73215.91FalseNoneNoneFalseNoneFalse351443.18430
3646484132942NoneItem 9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3500.983500.98547.79FalseNoneNoneFalseNoneFalse1917801.83420
3646485132942NoneItem 10.18Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4123.354123.3579.443FalseNoneNoneFalseNoneFalse327571.294050
3646486132942NoneItem 9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6540.46540.484.53FalseNoneNoneFalseNoneFalse552860.0120
3646487132942None02Item -01-2010Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4832.884832.8834.9FalseNoneNoneFalseNoneFalse168667.5120
3646488132942NoneItem 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm362.12362.12720.48FalseNoneNoneFalseNoneFalse260900.21760
3646489132942NoneItem 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1091.291091.29109.43FalseNoneNoneFalseNoneFalse119419.86470
3646490132942NoneItem 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1778.721778.72425.12FalseNoneNoneFalseNoneFalse756169.44640
3646491132942NoneItem 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg693.56693.56951.38FalseNoneNoneFalseNoneFalse659839.11280
3646492132942NoneItem 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm155.89155.896362.38FalseNoneNoneFalseNoneFalse991831.41820
3646493132942NoneItem 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm191.49191.491232.95FalseNoneNoneFalseNoneFalse236097.59550
3646494132942NoneItem 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm61.3761.3794.5FalseNoneNoneFalseNoneFalse5799.4650
3646495132942NoneItem 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm141.16141.1694.5FalseNoneNoneFalseNoneFalse13339.620
3646496132942NoneItem 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm65.0665.06239.9FalseNoneNoneFalseNoneFalse15607.8940
3646497132942NoneItem 8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm831.05831.05239.9FalseNoneNoneFalseNoneFalse199368.8950
3646498132942NoneItem 18.1Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg499.61499.61292.5FalseNoneNoneFalseNoneFalse146135.9250
3646499132942NoneItem 18.3Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 , Light reflection internal 10 to 15, light reflection external 10 to 20 , shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3735.443735.4445.0FalseNoneNoneFalseNoneFalse168094.80
3646500132942NoneItem 7.41Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2078.242078.24280.686FalseNoneNoneFalseNoneFalse583332.872640
3646501132942NoneItem 7.31Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1563.91563.9120.294FalseNoneNoneFalseNoneFalse188127.78660
17223352660000NoneNoneBuildingsTLH SHIRAHATTI CIVIL SF38788516.82
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3646502132943NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:COLUMNS-70% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum14421.6414421.64129.397FalseNoneNoneFalseNoneFalse1866116.951080
3646503132943NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:RCC BEAMS-60% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13573.3113573.31194.631FalseNoneNoneFalseNoneFalse2641786.898610
3646504132943NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:RCC SLAB-50% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12724.9812724.98308.799FalseNoneNoneFalseNoneFalse3929461.099020
3646505132943NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:SECOND FLOOR STAIRCASE -50% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12724.9812724.9816.79FalseNoneNoneFalseNoneFalse213652.41420
3646506132943NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:LINTELS-60% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13573.3113573.3120.33FalseNoneNoneFalseNoneFalse275945.39230
3646507132943NoneItem 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11917.9311917.9317.12FalseNoneNoneFalseNoneFalse204034.96160
3646508132943NoneItem 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget110900.55110900.5593.15FalseNoneNoneFalseNoneFalse10330386.23250
3646509132943NoneItem 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1624.011624.012362.989FalseNoneNoneFalseNoneFalse3837517.765890
3646510132943NoneItem 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1368.631368.63369.32FalseNoneNoneFalseNoneFalse505462.43160
3646511132943NoneItem 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum122501.74122501.742.202FalseNoneNoneFalseNoneFalse269748.831480
3646512132943NoneItem 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1259.541259.5436.0FalseNoneNoneFalseNoneFalse45343.440
3646513132943NoneItem 22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo681.83681.8372.0FalseNoneNoneFalseNoneFalse49091.760
3646514132943NoneItem 22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo464.89464.8914.0FalseNoneNoneFalseNoneFalse6508.460
3646515132943NoneItem 22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo185.95185.9572.0FalseNoneNoneFalseNoneFalse13388.40
3646516132943NoneItem 22.15.9Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo86.7786.77108.0FalseNoneNoneFalseNoneFalse9371.160
3646517132943NoneItem 22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo123.97123.9736.0FalseNoneNoneFalseNoneFalse4462.920
3646518132943NoneItem 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1304.171304.1736.0FalseNoneNoneFalseNoneFalse46950.120
3646519132943NoneItem 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos74.3874.38216.0FalseNoneNoneFalseNoneFalse16066.080
3646520132943NoneItem 20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr64.4664.46184.95FalseNoneNoneFalseNoneFalse11921.8770
3646521132943NoneItem 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4118.34118.396.36FalseNoneNoneFalseNoneFalse396839.3880
3646522132943NoneItem 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm8348.198348.1981.0FalseNoneNoneFalseNoneFalse676203.390
3646523132943NoneItem 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm7089.897089.8918.9FalseNoneNoneFalseNoneFalse133998.9210
3646524132943NoneItem 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg208.27208.272097.89FalseNoneNoneFalseNoneFalse436927.55030
3646525132943NoneItem 12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1381.031381.0336.0FalseNoneNoneFalseNoneFalse49717.080
3646526132943NoneItem 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem870.27870.27157.6FalseNoneNoneFalseNoneFalse137154.5520
3646527132943NoneItem 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4320.384320.3855.68FalseNoneNoneFalseNoneFalse240558.75840
3646528132943NoneItem 12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm7741.977741.9712.96FalseNoneNoneFalseNoneFalse100335.93120
3646529132943NoneItem 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm386.78386.783888.61FalseNoneNoneFalseNoneFalse1504036.57580
3646530132943NoneItem 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm261.57261.573011.62FalseNoneNoneFalseNoneFalse787749.44340
3646531132943NoneItem 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm102.89102.896900.23FalseNoneNoneFalseNoneFalse709964.66470
3646532132943NoneItem 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm432.65432.651533.415FalseNoneNoneFalseNoneFalse663431.999750
3646533132943NoneItem 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm438.85438.8591.854FalseNoneNoneFalseNoneFalse40310.12790
3646534132943NoneItem 8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr47.147.15577.0FalseNoneNoneFalseNoneFalse262676.70
3646535132943NoneItem 7.18Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum2500.492500.4928.4949FalseNoneNoneFalseNoneFalse71251.2125010
3646536132943NoneItem 15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm762.42762.42155.289FalseNoneNoneFalseNoneFalse118395.439380
3646537132943NoneItem 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr64.4664.461321.47FalseNoneNoneFalseNoneFalse85181.95620
3646538132943NoneItem 9.17.2Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1456.651456.651246.6FalseNoneNoneFalseNoneFalse1815859.890
3646539132943NoneItem 9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1643.851643.85278.688FalseNoneNoneFalseNoneFalse458121.26880
3646540132943NoneItem 9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3535.643535.64268.25FalseNoneNoneFalseNoneFalse948435.430
3646541132943NoneItem 10.18Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4164.174164.1780.478FalseNoneNoneFalseNoneFalse335124.073260
3646542132943NoneItem 9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6605.166605.1680.49FalseNoneNoneFalseNoneFalse531649.32840
3646543132943NoneItem 10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4880.734880.7336.408FalseNoneNoneFalseNoneFalse177697.617840
3646544132943NoneItem 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm365.71365.71732.588FalseNoneNoneFalseNoneFalse267914.757480
3646545132943NoneItem 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1102.11102.194.983FalseNoneNoneFalseNoneFalse104680.76430
3646546132943NoneItem 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1796.331796.33373.421FalseNoneNoneFalseNoneFalse670787.344930
3646547132943NoneItem 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg700.43700.43304.29FalseNoneNoneFalseNoneFalse213133.84470
3646548132943NoneItem 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm157.44157.446900.23FalseNoneNoneFalseNoneFalse1086372.21120
3646549132943NoneItem 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm193.39193.391533.415FalseNoneNoneFalseNoneFalse296547.126850
3646550132943NoneItem 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm61.9861.9899.89FalseNoneNoneFalseNoneFalse6191.18220
3646551132943NoneItem 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm142.56142.5699.89FalseNoneNoneFalseNoneFalse14240.31840
3646552132943NoneItem 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm65.765.7231.26FalseNoneNoneFalseNoneFalse15193.7820
3646553132943NoneItem 8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm839.28839.28231.263FalseNoneNoneFalseNoneFalse194094.410640
3646554132943NoneItem 18.1Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg504.56504.56292.5FalseNoneNoneFalseNoneFalse147583.80
3646555132943NoneItem 18.3Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3772.433772.4336.0FalseNoneNoneFalseNoneFalse135807.480
3646556132943NoneItem 7.41Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2098.822098.82243.95FalseNoneNoneFalseNoneFalse512007.1390
3646557132943NoneItem 7.31Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1579.381579.38104.55FalseNoneNoneFalseNoneFalse165124.1790
17223352660000NoneNoneBuildingsTLH Sihirahatti modular OT5723764.76
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3646558132944NoneItem 1Providing and fixing 50 mm thick prefabricated walkable stainless steel panels ceiling The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick. And these two sheets are held together with aluminum ‘w’ section of 48mm x 10.2mm for frame work & inner space between two sheets is filled with Puff insulation with density of 40KG per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtrs. The stainless steel surface should be brush / MAT finish with antiglare property. The false ceiling panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum ‘H ‘ section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon sealent to ensure air tight vapor tight construction. The false ceiling shall be walkable with provision of service panel. The false ceiling should be fixed to the concrete slab by using 8mm treaded tension bars with adjustable turn buckles, fastener, nuts, bolts etc., complete to the concrete slab. Coving: Providing corner joint coving for wall to wall used to provide smooth and seamless corner coving buffed aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile. The required size cut outs for fixing of lights & also for any other services shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift and etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ( Note: The panel should be free from scratches & dents ) MODULAR OT area -8 mtr X6 mtr apprxt. Say 50.00 Sqm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm10354.510354.550.0FalseNoneNoneFalseNoneFalse517725.00
3646559132944NoneItem 2Providing and fixing 50 mm thick prefabricated stainless steel wall panels. The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick and these two sheets are held together with aluminum W section size 48mm x 10.2mm for frame work and inner space between two sheets is filled with Puff insulation with density of 40KG per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtrs. The stainless steel surface should be brush / MAT finish with antiglare property. The wall panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum H section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon to ensure air tight vapour tight construction. Coving:Providing corner joint coving used to provide smooth and seamless corner coving buffed Aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile. The covings shall be provided wall to wall, wall to ceiling, wall to floor. The required size cut outs for fixing of control panel and switch plate shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ( Note: The panel should be free from scratches & dents ) 6 mtr X 3 mtr X2 Nos. =36 Sqmtr 8 mtr X 3 mtr X2 Nos. =48 Sqmtr Say 84.00 Sqm ( Door area will be detected form wall panel) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm10354.510354.584.0FalseNoneNoneFalseNoneFalse869778.00
3646560132944NoneItem 3Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Srub Door /Dirty utility Door (single leaf) 1 mtr X 2.10 mtr Say 2.10 Sqmtr ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm53843.3953843.392.1FalseNoneNoneFalseNoneFalse113071.1190
3646561132944NoneItem 4Supplying and Fixing HERMATICALLY SEALED STAINLESS STEEL SLIDING DOOR Providing, fabrication and fixing of manually operated hermetically sealed stainless steel sliding door of size1500 x 2100mm. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. The sliding Door runs on Nylon wheel within an Aluminium extrusion high quality rail complete with required accessories. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including SS 304 grade handles- 02 sets, SS concealed Tower Bolt, etc., Complete are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm96585.3696585.363.5FalseNoneNoneFalseNoneFalse338048.760
3646562132944NoneItem 5Antistatic Epoxy Flooring : Providing and laying 4mm thick anti-static, anti-fungal and anti-bacterial epoxy flooring after preparing the floor surface by removing all loose particles, dirt by using coir brush and vacuum cleaner. Applying one coat of Moisture barrier primer and then applying self-leveling 2mm thick moisture barrier layer to capture the moisture of the existing flooring. Then the anti static grid is laid with conductive granules and copper strips. Then apply one coat of epoxy based primer and allow for dry 6 8 hours. Then apply epoxy putty and allow for dry 6 8 hours. And then apply 2 mm thick self-leveling epoxy flooring of approved make, colour and shade. The Epoxy flooring should be impact resistance, chemical resistance including abrasion and fumigation with R75mm coving wall to wall, wall to flooring etc., The cost includes cost of material, labour, transportation etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3835.03835.054.0FalseNoneNoneFalseNoneFalse207090.00
3646563132944NoneItem 6Supplying and Fixingof 2'x2' LED recessed luminarie with…. Watts system wattage. Housing shall be with pressure die cast aluminium alloy with corrosion proof resistant polyester powder coated. Driver operates with voltage range from 100v to 270V 50/60 Hz with short circuit, overload & mis-wring protection. Lumen maintenance of 70% at 50000 Hrs. injection moulded poly carbonate diffuser for better mechanical stability, light transmission & avoid pot hole effect. Junction temperature shall be less than 70 degree Celsius. Driver is on constant current driver @ 0.06A with PF greater than 0.9, line voltage @ 50Hz, driver efficiency greater than 85% & THDless than 15%. LED Efficiency greater than 130 Im/W & Fixture Efficiency greater than75lm/w with CRI greater than 75 with injection moulded Polycarbonate lens with less than 8mm depth. 5 years Warranty against any manufacturing defect working under standard electrical condition.] ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach9725.569725.568.0FalseNoneNoneFalseNoneFalse77804.480
3646564132944NoneItem 7Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X ray viewing screen shall be concealed with wall panel. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
3646565132944NoneItem 8Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6903.06903.01.0FalseNoneNoneFalseNoneFalse6903.00
3646566132944NoneItem 9Plenum Laminar Flow :Supply and installation of Stainless steel 304 grade Plenum LAMINAR FLOW- Plan air Ceiling mounted system with unidirectional airflow,(Air flow velocity of 25 to 35 FPM) Plenum unit, Holding structure & Top plenum are conforming to DIN 4799 / EU14 (Mini pleate HEPA filter) standards for the air distribution system complete with provision for 6 Nos. (Size 1220mmX610mmX90mm thick) HEPA Filters (efficiency 99.97% down to 0.3 micron ), 4000 cfm. The Plenum size is 1800 x 2400mm. The Diffuser is made out of SS 304 Grade material for laminar of filtered air. The complete unit will have factory prepared fine sealing system. It will be perfectly seamless. It will be made out of SS 304 Sheet of required thickness With perforated SS 304 sheet with etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach312700.0312700.01.0FalseNoneNoneFalseNoneFalse312700.00
3646567132944NoneItem 10Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3646568132944NoneItem 11Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisiting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceted accessories. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
3646569132944NoneItem 12Supplying and Fixing OT control Panel 6 Tile : Supply and installation of 6 tile OT control panel with distribution box, control panel will be mounted flush in the theatre wall, comprising of the following 1. Medical gas card2. Laminar Air flow controls Temperature & humidity indicators, filter status, temperature & humidity control.3. Digital elapsed timer 4. Hand free phone5. Digital day timer clock6. Lighting control panel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach129800.0129800.01.0FalseNoneNoneFalseNoneFalse129800.00
3646570132944NoneItem 13Providing & fixing SS304 grade return air grill. The cut out for return air grill size in panel is 600mmX450mm. The cost includes cost of material, labour charges for fixing etc complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4130.04130.04.0FalseNoneNoneFalseNoneFalse16520.00
3646571132944NoneItem 14SUPPLY ERECTION TESTING & COMISSIONING of Return air riser made out of SS 304 grade with 18 SWG in the clean room area of 1000 CFM and provision for return air collar damper anf grill with all concted accessories. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach21240.021240.04.0FalseNoneNoneFalseNoneFalse84960.00
3646572132944NoneItem 15Supplying and Fixing Providing and making trap door of size 600 x 600mm in the ceiling panel by cutting. The required frame work shall be made by using Aluminium sections. The cost includes cost of material, labour charges for fixing etc complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7375.07375.01.0FalseNoneNoneFalseNoneFalse7375.00
3646573132944NoneItem 16AHU's RECYCLE SYSTEM FOR OT AREA AS PER NABH NORMS :SUPPLY ERECTION TESTING & COMISSIONING Air handling units of GSS powder coated sheet metal cabinet type Double skin Recirculatory type 40-45 mm thick,Thermal break,modular construction.Air handling units shall be complete with Backward curved blower having capacity of 3500 t0 4000 cfm (Minimum 25 to 35 ACPH ) with 125 mm capacity, 3.75kw TEFC motor,fan motor drive filter section with 10 microns pre filter,3 microns fine filters, DX coil 6 row section of copper coil with aluminium fins,Mist eleminator, inlet and outlet volume control dampers and bypass dampers with access doors and accessories including 10% Fresh air with module with console type and grill, 20 Microns Fresh air filter. 10% Bleed module with hepa filter,damper and grille, View glass, View lamp, limit switch for door & Pressure port for filter sections & provision to fix pressure port to measure the pressure drop across the filter, ( EFF1 Motor ) coil should be 5. 5 TR x 2 circute with all concted accessories. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo597788.0597788.01.0FalseNoneNoneFalseNoneFalse597788.00
3646574132944NoneItem 17AIR COOLED CONDENSER UNIT & COPPER PIPING :SUPPLY ERECTION TESTING & COMISSIONING 5.5 TR Air cooled out door condensing units comprising of semi -hermetic / hermetic reciprocating/scrool compressors with matching air cooled condenser suitable for 3500 to 4000 CFM AHU) provided with necessary controls.like Thermostart , Draier with MS painted stand ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo146320.0146320.02.0FalseNoneNoneFalseNoneFalse292640.00
3646575132944NoneItem 18GRILLE & DAMPER:SUPPLY ERECTION TESTING & COMISSIONING Collar damper made out of Al. with powder coated as per return air openinig size ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm10384.010384.02.0FalseNoneNoneFalseNoneFalse20768.00
3646576132944NoneItem 19SUPPLY ERECTION TESTING & COMISSIONING Aluminium Volume control dampers manual operated, Only for hepa module, unit mouth & branch Ducts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm13924.013924.02.0FalseNoneNoneFalseNoneFalse27848.00
3646577132944NoneItem 20SUPPLY ERECTION TESTING & COMISSIONING Fire Dampers with Fusible Links rated for 72 C for AHU mouth, with fire damper actuator with inter link with AHU controll panel in case of fire AHU motor should stop. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo6254.06254.01.0FalseNoneNoneFalseNoneFalse6254.00
3646578132944NoneItem 21SUPPLY ERECTION TESTING & COMISSIONING Fire retardant flexible connections for AHU supply & return air mouth ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo5546.05546.02.0FalseNoneNoneFalseNoneFalse11092.00
3646579132944NoneItem 22DUCTING & INSULATION:SUPPLY ERECTION TESTING & COMISSIONING Al. ducting including the supports,selicon sealent with painted MS angle flanges.a)22 guage ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2006.02006.0160.0FalseNoneNoneFalseNoneFalse320960.00
3646580132944NoneItem 23aSUPPLY ERECTION TESTING & COMISSIONING Supply & return air duct Insulation with factory laminated Al. foil class 'O' grade:13 mm thk for return air duct ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm920.4920.480.0FalseNoneNoneFalseNoneFalse73632.00
3646581132944NoneItem 23bSUPPLY ERECTION TESTING & COMISSIONING Supply & return air duct Insulation with factory laminated Al. foil class 'O' grade:19 mm thk for supply air duct ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1097.391097.3990.0FalseNoneNoneFalseNoneFalse98765.10
3646582132944NoneItem 24Polishield covering with two coats paint for exposed duct ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1038.391038.3970.0FalseNoneNoneFalseNoneFalse72687.30
3646583132944NoneItem 25SUPPLY & Fixing 300 dia Insulated flexible connection for grille module & return air raiser ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr979.4979.420.0FalseNoneNoneFalseNoneFalse19588.00
3646584132944NoneItem 2625 mm PVC dia drain piping with supports for AHUs ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr625.4625.450.0FalseNoneNoneFalseNoneFalse31270.00
3646585132944NoneItem 27SUPPLY ERECTION TESTING & COMISSIONING Ele.controll panel inter lock with AHUs and 5.5 TR 2 nos condenser unit with TEMP. & RH Controller For AHU ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet12272.012272.01.0FalseNoneNoneFalseNoneFalse12272.00
3646586132944NoneItem 28SUPPLY ERECTION TESTING & COMISSIONING 4 Kw Ele. Heater with RH controller to controll humidity of 50 to 60% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet66788.066788.01.0FalseNoneNoneFalseNoneFalse66788.00
3646587132944NoneItem 29a)Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP 4C X 6 Sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr218.29218.2960.0FalseNoneNoneFalseNoneFalse13097.40
3646588132944NoneItem 29b)Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP 4C X 4 Sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr177.0177.060.0FalseNoneNoneFalseNoneFalse10620.00
3646589132944NoneItem 29c)Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP 4C X 2.5 Sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr123.89123.8930.0FalseNoneNoneFalseNoneFalse3716.70
3646590132944NoneItem 29d)Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP 8C X 2.5 Sqmm S.R. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr348.09348.0930.0FalseNoneNoneFalseNoneFalse10442.70
3646591132944NoneItem 29e)Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP 4C X 10 Sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr348.09348.0930.0FalseNoneNoneFalseNoneFalse10442.70
3646592132944NoneItem 30SUPPLY & Fixing Cable trey:300 width x 50 ht perforated P. No.63 Item No.7.19.2 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr645.45645.4530.0FalseNoneNoneFalseNoneFalse19363.50
3646593132944NoneItem 31Plate COpper Earthing strip 24 x 3 mm connected to existing earthing P.55 Item No.7.3.6 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr617.14617.1450.0FalseNoneNoneFalseNoneFalse30857.00
3646594132944NoneItem 32SUPPLY & FIXING DP Gauge range 0 to 6 mm wg for OT room to monitoring positive pressure ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos10089.010089.01.0FalseNoneNoneFalseNoneFalse10089.00
3646595132944NoneItem 33DSUPPLY & FIXING DP Gauge range 0 to 50 mm wg for AHU & EAU pre & fine filter section to monitoring pressure drop in the filters ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos9735.09735.02.0FalseNoneNoneFalseNoneFalse19470.00
3646596132944NoneItem 34Supplying & Fixing Single Arm Rotating OT Pendant: Single ARM 320 Deg Rotating Anesthesia Pendant Complete with Electrical Outlets (8 Nos), Data Points (1 Nos) and Medical Gas Outlets (7 Nos), 1 Monitor Tray, 2 Nos. Shelfs, 2 Nos I V StandNote: 2 SET of DOCUMENTS & VALIDATION AT REST AS PER ISO-14644 and NABH standard to be submitted Design Qualification, Installation Qualification, Operational Qualification, Performance Qualification,Air velocity test,Air changes test,Air qty.check test,Temp. & RH test,DOP test for Hepa filter,Partical count test (Class 100, ISO - 5in the termial ),Air flow pattern test,Recovery test,Majot materil test certificates. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos194700.0194700.02.0FalseNoneNoneFalseNoneFalse389400.00
3646597132944NoneItem 36Scrub Station MOT SCRUB STATION (minimum size 1500 mm) supply , installation and commissioning of compact surgical scrub sink shall be designed for use in OT area for pre-procedural scrub. Double sink combination shall be provided. Fabricated from heavy gauge type 304 stainless steel (minimum thicknes 1.5 mm) and shall be of seamless welded construction, polished to a satin finish.With a front access panel which shall be easily removable for access to the water controlled valve, waste connections, stoppers and strainers. Hands free operation shall include infra-red sensors with programmable adjustment. .Thermostatic mixing, valve control shall be located behind the access panel and it shall maintain constant water temperature.Timing shall be adjustable to meet individual application requiements.(built in with timer setting from 1 to 10 mic)It shall be provided with infrared sensors, thermostatic control taps with fail safe temprerature controls. All units shall have reduced anti-splash fronts.Knee/foot operated switch shall be provided additionally with all connected accessories. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos278480.0278480.01.0FalseNoneNoneFalseNoneFalse278480.00
3646598132944NoneItem 37Supply , installation, testing and commissioning OT surgical Lighting system with connected accessroies MOT surgical lighting system shall provide an ideal combination of brightness, manoeuvrability and shadow resolution without sacrificing colour and accuracy through a consistent LED technology. Such lighting system shall have the following technical specifications: a) Number of light heads :Two b) Rotation system : 360 C c) Colour temperature range : 3800 K to 5000 K (10%)-variable colour temperature. d) CRI : 93 Ra. e) LED's : Low temp . 3 Colours combination. f) LED bulb life : 50,000 hrs. g) Field size diameter : 20 to 28 cm (10%) h) Working range : 750 to 1100 mm (10 per ) i) Focus : Adjustable 100mm-250mm. j) Illumination leve l: minimum 160,000 lux (both for major dome and minor dome separately). k) Controls control panel ( two:one on the wall and other on dome/ digital with wireless remote). l) Power supply : 220 V/ 50Hz AC. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos413118.0413118.01.0FalseNoneNoneFalseNoneFalse413118.00
17223352660000NoneNoneBuildingsTLH Shirahatti MGPS16031585.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3646599132945NoneItem 1OXYGEN MAIN MANIFOLD SYSTEM : 40 cylinder (20+20) Oxygen Manifold should be suitable to withstand a pressure of 140 Kg/Cm2and above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising high pressure copper pipes of size 12mm I.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 psig. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet224554.0224554.01.0FalseNoneNoneFalseNoneFalse224554.00
3646600132945NoneItem 2Micro process based Automatic High flow Upto 2200 ltrs/min Oxygen Control Panel. Fully automatic changeover panel 3 SOURCE FULLY AUTOMATIC OXYGEN CONTROL PANEL Working Pressure from the oxygen concentrator plant 4.1 kg/cm2 (Future Provision). Working Pressure from fully automatic control panel. 4.1 kg/cm2. Working Pressure from Emergency manifold system 4.1 kg/cm2. Changeover unit of all 3 sources should be at the pressure from oxygen concentrator plant Below 4.1kg/cm2. Changeover unit of all 3 sources should be at the pressure from main Manifold system Below 4.1kg/cm2.Changeover unit of all 3 sources should be at the pressure from Emergency manifold system Below 4.1kg/cm2. The Control panel shall be of fully integrated type with all safety features inbuilt for high pressure and high flow Upto 2200 ltrs / min Oxygen system. All the electrical circuits should be operated at 12 volts & 24 volts with provision of inbuilt power conversion equipment. The Panel shall have the necessary instruments, gauges, LED Indicators etc. complete with separate indicators far from separate 3 sources. Pressure from oxygen concentrator plant Green signal for Normal pressure & Red signal for Low pressure. Pressure for manifold system Green signal for Normal Pressure & Red signal for low pressure.Left bank Green signal for Normal Pressure & Red for Low pressure. In Right bank Green signal for Normal Pressure & Red for Low pressure. In Emergency manifold Green signal for Normal Pressure & Red for Low pressure. Main Line Green signal for Normal Pressure & Red for Low pressure. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos217120.0217120.01.0FalseNoneNoneFalseNoneFalse217120.00
3646601132945NoneItem 3OXYGEN MANIFOLD SYSTEM :EMERGENY The Control pannel shall be of fully integrated type with all saftety futures inbuilt for high pressure and high flow upto 2200 ltrs / min Oxygen system. 4+4 Cylinder Oxygen Manifold Should be suitable be withstand a pressure of 140 Kg/Cm2and above, along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mmI.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick and a single state high pressure high flow regulator connected to a high pressure brass block. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 psig and necessary test certificates should accompany along with the supply. SEMI AUTOMATIC EMERGENCY OXYGEN MANIFOLD CONTROL PANEL Semi automatic control panels designed for various control functions required during supply of oxygen through the manifold unit. Enclosed in a metal cabinet. This semi automatic control panel is highly efficient in triggering the signal for the Reserve system to go operational in case primary and secondary system fails in emergency. This panel is normally connected in a permanent mode and change over is semi automatic. Some of the features of this pannels are as follows :   Control panel shall be made of M.S.duly powder coated. Easy maintenance. Highly reliable.   Designed for safety and continuity of flow supply at a constant pressure.   Pressure gauge facility to indicate the gas pressure of each header and pipe line distribution pressure. Capable to provide a distribution flow rate in excess of 1500LPM. Should have Incorporation of safety features in case pressure exceeds 100Psi. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet155760.0155760.01.0FalseNoneNoneFalseNoneFalse155760.00
3646602132945NoneItem 4NITROUS OXIDE SUPPLY SYSTEM NITROUS OXIDE MAIN MANIFOLD SYSTEM Supply, Installation, Testing and commissioning of 2 cylinder (1 + 1) Nitrous Oxide manifold supply with all necessary controls and safety fittings. Make of AKTIV or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work SEMI AUTOMATIC NITROUS OXIDE MAIN MANIFOLD CONTROL PANEL Supply, Installation, Testing and commissioning of 500 lpm deliver capacity manifold control panel, control panel should have all necessary controls and safety fittings. with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Nitrous Oxide System ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet88500.088500.01.0FalseNoneNoneFalseNoneFalse88500.00
3646603132945NoneItem 5NITROUS OXIDE EMERGENCY MANIFOLD SYSTEM Supply, Installation, Testing and commissioning of 1 cylinders Nitrous Oxide manifold supply with all necessary controls and safety fittings and 0 To 10 Kg/cm2 High Presuure Regulator complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet47200.047200.01.0FalseNoneNoneFalseNoneFalse47200.00
3646604132945NoneItem 6MEDICAL AND SURGICAL AIR SYSTEM Compressed Air System: System For Medical use. Type : Reciprocating, Air cooled, Oil/ Grease free Capacity of Piston Displacement : 52.7 cfm 1620 Lpm Drive : Belt driven No. of Air Compressors : 2 Nos. (1W + 1S by) Motor Capacity : 15 HP as required Receiver Capacity : 2000 liters water capacity After Reservoir shall have oil seperator and Moisture Receiver type : Automatic Vertical type with inlet, outlet & drain provisions ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet1770000.01770000.01.0FalseNoneNoneFalseNoneFalse1770000.00
3646605132945NoneItem 7Duplex Medical Air Dryer System ( Breathing Air System) (2 Nos of 1 set) 100 CFM Air Dryer Min Working Pressure should be 4 bar, Rated Inlet Pressure should be 7 bar Max ,Working Pressure should be 16 bar, Supply Voltage Should be 100-240 VAC, 50/60 Hz, 1 Ph ,Rated Inlet temperature should be 38 deg C ,Dryer capable to give should be 40, PDP Purge Loss 15%,Air quality As per NFPA 99, Dual System, Three stage filter (Dessicated drier), CO & Dew point level as per NFPA 99, Bacterial Penetration 0.00001% ,Failure Indication, Purge Saving control Manual ,No refrigerant used , Energy saving Dew point based dryer cycling ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet118000.0118000.01.0FalseNoneNoneFalseNoneFalse118000.00
3646606132945NoneItem 8DUPLEX COMPRESSED AIR BREATHING FILTERATION SYSTEM 3 STAGE The filters Shouldhave maximum contaminant removal efficiency with minimum pressure drop. The filtration system should conform to breathing air filtration as per ISO 8573 Ch I Standard. Total 3-stages of filters Shouldbe used as mentioned below: Stage 1: Oil aerosol contents removal up to 0.5 mg/cum. Stage 2: Oil aerosol contents removal up to 0.01 mg/cum. Stage 3: Oil content removal up to 0.003 mg/cum along with removal of oil vapor and hydrocarbon odor as per ISO 8573 Ch-I Standard. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3646607132945NoneItem 9Air Cooler : Supply, Installation, Testing and Commissioning of 80 CFM Air cooler system, with 3 phase fan (High RPM Fan) suitable for 415 V, 3Phs 50 Hz ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3646608132945NoneItem 10VACCUM SUPPLY SYSTEM The pump installation shall be Duplex system consisting of 2 Nos (1W+1S BY) identical Rotary Vane Type Pumps each of which shall be capable of independently producing designed systems flow rate. The pump shall be clearly marked with its performance, both its free air displacement and its volumetric throughput. Each pump should have capacity of minimum 4928LPM (300m3/h) i.e., 176 CFM. Pump should be capable of providing a vacuum of not less than 650 mm Hg (87 kPa). The driving motor shall directly drive the pump unit and it shall be manufactured in accordance with HTM 2022/HTM 02-01 / conforms to IEC Standards. Recommendations suitable for 415 voltes, 3 phase, 50 Hz power supply.Each pump shall have a built in non-return valve and pressure switch such that inadvertent reversal of the motor Should not pressurize the Reservoir or the distribution system protection. Compartments, two compartments shall hold the motor starters, MCBS ammeters, and hour’s run-meters, for each pump. The remaining compartment shall house the vacuum switches, status monitoring equipment, delay timer and necessary interlock, selector switch with automatic change over, etc., complete with internal wiring using copper conductors. Control Panel system should be front operable. The control panel shall consist of three separate , The system should include vacuum storage reservoir tank, Rated for full vacuum services with the storage capacity of approx 3000Ltr (2Nos Receiver Tank) as per standard recommendation. It should be equipped with an vacuum gauge and provision for manual draining by pass valve. The inside of the tank should be coated with a two-component coating to provide a hard, durable lining for rust ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet1593000.01593000.01.0FalseNoneNoneFalseNoneFalse1593000.00
3646609132945NoneItem 11VACUUM BACTERIAL FILTERATION, Suitable Medical Vacuum filters are used for removal of bacteria & other contamination from the suction side of vacuum pumps, preventing infection of pump and the atmosphere. These elements shall be of pleated construction giving a high surface area and long operational life. The efficiency to exceed the 0.005% penetration specified in HTM2022 for infectious disease unit.- i.e. complete bacterial removal. Elements shall be fitted in an aluminum housing suitable for various capacities. These are to be internally protected against corrosion by an alocrom treatment. The inner & outer surfaces of the housing are epoxy coated. Complete assembly shall be fitted with a sterilisable drain flask with isolation valve for removal of liquid if any. Differential pressure indicators are to be provided to monitor the status of element. Basics Specifications are as given below. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet165200.0165200.01.0FalseNoneNoneFalseNoneFalse165200.00
3646610132945NoneItem 12Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work:Copper Pipe 54mm. ODx1.2 mm.thick. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr4854.514854.5180.0FalseNoneNoneFalseNoneFalse388360.80
3646611132945NoneItem 13Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work:Copper Pipe 42mm. ODx1.2 mm.thick. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr3608.443608.44150.0FalseNoneNoneFalseNoneFalse541266.00
3646612132945NoneItem 14Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work:Copper Pipe 35mm. ODx1.2 mm.thick. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr2570.042570.04230.0FalseNoneNoneFalseNoneFalse591109.20
3646613132945NoneItem 15Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work:Copper Pipe 28mm. ODx0.9 mm.thick. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr1492.71492.7360.0FalseNoneNoneFalseNoneFalse537372.00
3646614132945NoneItem 16Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work:Copper Pipe 22mm. ODx0.9 mm.thick. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr1156.41156.41220.0FalseNoneNoneFalseNoneFalse1410808.00
3646615132945NoneItem 17Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work:Copper Pipe 15mm. ODx0.9 mm.thick. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr949.9949.91970.0FalseNoneNoneFalseNoneFalse1871303.00
3646616132945NoneItem 18Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work:Copper Pipe 12mm. ODx0.7 mm.thick. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr651.36651.36820.0FalseNoneNoneFalseNoneFalse534115.20
3646617132945NoneItem 19Oxygen Outlets - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos3392.53392.5205.0FalseNoneNoneFalseNoneFalse695462.50
3646618132945NoneItem 20Vacuum Outlets - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos3392.53392.5154.0FalseNoneNoneFalseNoneFalse522445.00
3646619132945NoneItem 21Compressed Air Outlets 4 Bar - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos3392.53392.5155.0FalseNoneNoneFalseNoneFalse525837.50
3646620132945NoneItem 22Compressed Air Outlets 7 Bar- drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos3392.53392.56.0FalseNoneNoneFalseNoneFalse20355.00
3646621132945NoneItem 23Nitrous Oxide Outlets - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos3392.53392.58.0FalseNoneNoneFalseNoneFalse27140.00
3646622132945NoneItem 24ACCESSORIES ALONG WITH CALIBRATION CERTIFICATES. Oxygen Flow meter with Humidifier Bottle: Flow meter should be Backpressure Compensated. Flow meter should be accurate gas flow measurement and control within a range of 0-15 liters per minute.         It should meet strict precision and durability standards.          Flow meter body should be made of brass material.        Flow tube and shroud components should be made of clear, impact resistant polycarbonate.         The humidifier bottle should be unbreakable polycarbonate material and autoclavable at 134 degrees centigrade. The humidifier should have built in safety valve.With Calibration Certificate’s. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2849.72849.7154.0FalseNoneNoneFalseNoneFalse438853.80
3646623132945NoneItem 25Single piece wall mounted suction collection & regulation unit. With jar capacity of 600ml each shall be provided at each of the bed side. Jars are should be made of autoclavable materials. The units shall be clamped to the wall using suitable clamps.With Calibration Certificate’s. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos3528.23528.2148.0FalseNoneNoneFalseNoneFalse522173.60
3646624132945NoneItem 26Theatre Vacuum Unit:The unit should comprise of two reusable 2000 ml shatter resistant bottle, each made up of poly carbonate material and fully auto cleavable at 134 degree centigrade. Should have a vacuum regulator with instant ON / OFF switch a three way selector switch with an option to operate either,-Left right or both ,All the above items Should be mounted on a Trolley having a free moving castor wheels. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos14750.014750.03.0FalseNoneNoneFalseNoneFalse44250.00
3646625132945NoneItem 27ISOLATION VALVES:Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction:Isolation Valves 54 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos8826.48826.42.0FalseNoneNoneFalseNoneFalse17652.80
3646626132945NoneItem 28ISOLATION VALVES:Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction:Isolation Valves 42 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos8142.08142.03.0FalseNoneNoneFalseNoneFalse24426.00
3646627132945NoneItem 29ISOLATION VALVES:Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction:Isolation Valves 35 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos5428.05428.07.0FalseNoneNoneFalseNoneFalse37996.00
3646628132945NoneItem 30ISOLATION VALVES:Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction:Isolation Valves 28 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos4071.04071.05.0FalseNoneNoneFalseNoneFalse20355.00
3646629132945NoneItem 31ISOLATION VALVES:Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction:Isolation Valves 22 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos3392.53392.513.0FalseNoneNoneFalseNoneFalse44102.50
3646630132945NoneItem 32ISOLATION VALVES:Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction:Isolation Valves 15 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2714.02714.072.0FalseNoneNoneFalseNoneFalse195408.00
3646631132945NoneItem 33Zonal Valve box five Gas services An Zonal area valve box should have bellow spec:Wall mounted M.S. box with powder coated & lockable,Front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.The valve box door cannot be close during valve close position. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos23364.023364.03.0FalseNoneNoneFalseNoneFalse70092.00
3646632132945NoneItem 34Zonal Valve box three Gas services An Zonal area valve box should have bellow spec:Wall mounted M.S. box with powder coated & lockable,Front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.The valve box door cannot be close during valve close position. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos18319.518319.59.0FalseNoneNoneFalseNoneFalse164875.50
3646633132945NoneItem 35Digital Area Alarm for five Gas Systems:Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos41300.041300.03.0FalseNoneNoneFalseNoneFalse123900.00
3646634132945NoneItem 36Digital Area Alarm for Three Gas Systems:Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos34220.034220.09.0FalseNoneNoneFalseNoneFalse307980.00
3646635132945NoneItem 37Bed Headed Panel and Railing. 1.5meter Double railing Bed headed panels should have below Specifications. Accessories 1. IV Stand extendable type with aluminium slider. 2. Monitor stand wall panel mounted. 3. Ward vaccum unit slider. 4. 3/6W LED light fixture. 5. Twpo duplex 230 V,6/16 Amp 6 nos of 6 amps sockets with control switchesElectrical Sockets. Provision Medical Gas Terminal Units as follows.  2.1 Two oxygen outlet. 2.2  One Vacuum outlet. 2.3 One compressed Air outlet 4 Bar. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos31860.031860.045.0FalseNoneNoneFalseNoneFalse1433700.00
3646636132945NoneItem 38Anaesthesia Single Arm Pendant: The material of the Pendent should be Single-armed rotary ceiling mounted surgical Pendent High-strength aluminum alloy. Extension arm 700mm.Loading capacity: 70-150kg.Level degrees rotation:340n.w.:158kg.Should be provision for Gas outlets Oxygen 02 nos, Vaccum 01 nos,Air 4 Bar 01 nos,Air 7 Bar 01 nos, Nitrous Oxide01 nos,Power socket 08 nos,Grounding terminal 01 nos,Platform 03 nos, IV pole 01 nos,Drawer 01 nos. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos194700.0194700.02.0FalseNoneNoneFalseNoneFalse389400.00
3646637132945NoneItem 39Conversion Kit for Anesthesia for Oxygen. Should have high pressure antistatic tubing which is color coded. ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1652.01652.03.0FalseNoneNoneFalseNoneFalse4956.00
3646638132945NoneItem 40Conversion Kit for Anesthesia for Nitrous Oxide. Should have high pressure antistatic tubing which is color coded. ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1652.01652.03.0FalseNoneNoneFalseNoneFalse4956.00
17223352660000NoneNoneBuildingsTLH Shirahatti Furniture works8863088.61
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3646639132946NoneItem 1Providing and fixing storage unit of 0.75m width made out of 19mm thick commercial ply vertical support finished in approved 1.5mm laminate with 12mm thick ply packing internally & Externally finish, shelves shall be formed out of 19mm ply finished with 1.5mm laminate of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.5mm thick laminate of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm11493.1911493.19245.238FalseNoneNoneFalseNoneFalse2818566.929220
3646640132946NoneItem 2Table : Providing and fixing Executive tables of different sizes with 19 mm waterproof plywood frame work laminated on all the exposed surface with 1 mm thick laminate and a key board tray is provided and all edges of the plywood is lipped with 19mm x 6mm teak/beach wood lipping and the edge of the table top is lipped with 32 mm x 19 mm teak/beach wood lipping. The item to include a side cabinet with 19 mm thick waterproof plywood framework, shelves and shutters laminated on all the exposed surface with 1mm thick laminate and inside surface is also laminate with 0.8 mm laminate. The item to include all hardware like stainless steel hinges, drawer sliders, Euro multipurpose locks, brush steel handles, magnetic catch, all hardware complete and all the teak/beach wood beading is polished. Table 2400 mm x 900 mm x 750 mm ht, Side Table 1100 mm x 450 mm x 750 mm ht. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet41654.041654.023.0FalseNoneNoneFalseNoneFalse958042.00
3646641132946NoneItem 3Table : Providing and fixing Executive tables of different sizes with 19 mm waterproof plywood frame work laminated on all the exposed surface with 1 mm thick laminate and a key board tray is provided and all edges of the plywood is lipped with 19mm x 6mm teak/beach wood lipping and the edge of the table top is lipped with 32 mm x 19 mm teak/beach wood lipping. The item to include a side cabinet with 19 mm thick waterproof plywood framework, shelves and shutters laminated on all the exposed surface with 1mm thick laminate and inside surface is also laminate with 0.8 mm laminate. The item to include all hardware like stainless steel hinges, drawer sliders, Euro multipurpose locks, brush steel handles, magnetic catch, all hardware complete and all the teak/beach wood beading is polished:Table 2100 mm x 750 mm x 750 mm ht, Side Table 1100 mm x 450 mm x 750 mm ht ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet31270.031270.07.0FalseNoneNoneFalseNoneFalse218890.00
3646642132946NoneItem 4Providing and fixing Main table 1500x750x735mm, table top 25mm thick PLPB 1000x450x735mm, 25 MM THICK PLAIN PARTICLE BOARD (PPB) CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK Main and Side tables BACKINGLAMINATE (BDL). FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD (PPB)CLAD WITH 1.0MM THICK DECORATIVE LAMINATE (DL) ON BOTH SIDES. EDGE SEALED WITH 2MM THICK PVC BEADING 25 MM THICK PLAIN PARTICLE BOARD (PPB) CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK BACKINGLAMINATE (BDL). FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD (PPB)CLAD WITH 1.0MM THICK DECORATIVE LAMINATE (DL) ON BOTHSIDES. EDGE SEALED WITH 2MM THICK PVC BEADING. etc. as per approved drawing and directed by the engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet27730.027730.015.0FalseNoneNoneFalseNoneFalse415950.00
3646643132946NoneItem 5Providing and fixing of Three Seater Stainless Steel Waiting Chair complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. (Hassan Approved Rate)GROUND FLOOR &FIRST FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach42480.042480.046.0FalseNoneNoneFalseNoneFalse1954080.00
3646644132946NoneItem 6Optima Chairs with High Back with mesh and lumber support SEAT/BACK ASSEMBLY: The Cushioned seat assembly consists of seat outer (material-30% Glass Fiber Filled Nylon)& upholstered Seat inner (material- Poly Propylene) with moulded Polyurethane foam & polyester fabric. The Net Back is made up of Back outer (material-Glass Fiber Filled Nylon)& Back inner (material- PP) upholstered with polyester Mesh fabric. FULL BACK SIZE: 46.5 cm. (W) x 60.0 cm. (H) SEAT SIZE : 51.0 cm. (W) x 49.0 cm. (D) POLYURETHANE FOAM: The Polyurethane foam is moulded with density = 45 +/- 2 kg/m , ) ARMRESTS : The armrest is having two adjustment, Height and Depth. Height adjustment is provided in Aluminum structure of armrest which is connected to Aluminum Back spine And is operated by button. The depth adjustment is provided in pad which is fixed to armrest structure. Armrest Top is made up of PU molded over plastic inner. LUMBAR SUPPORT ASSEMBLY: The Lumbar suport assembly consists of lumbar spine (material-Glass Fiber Filled Nylon) which is fixed to Aluminum Back spine. The Lumbar pad (material- Poly Propylene) is fixed to lumbar spine through lumbar Pad support. Lumbar Support Assembly has height adjustment of 50mm. Neck-rest ASSEMBLY: The Neck-rest assembly consists of upholstered Neck-rest inner (material- Poly Propylene) etc., complete as per the direction of Engineer in charge of the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo19470.019470.073.0FalseNoneNoneFalseNoneFalse1421310.00
3646645132946NoneItem 7STAFF CHAIRS : Supplying HIGH BACK Chair Blue mango with contact crome flex back chair with co-active synchro, gas lift, revolving, tilting, and height adjustable fully cushioned medium back chairs and two way adjustable arms. prior confirmation shall be obtain from the officer / Architect for approval. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo7316.07316.088.0FalseNoneNoneFalseNoneFalse643808.00
3646646132946NoneItem 8Providing and fixing Centre Teapoy of size of 900 x 600mm oval shape as per principal chief architecht dwg no 120816/16 made out of good quality Burma Teak wood legs of cross section 50 x 10 mm and side bars of 50 x 60mm with 12mm thick modi guard glass top wtih edge grainding on polishing of oval shape of 900 x 600mm as per dwg. Polished with melamine finish in spray with necessary compressor Complete with all materials, labour, leads lifts etc and directed by Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo10856.010856.012.0FalseNoneNoneFalseNoneFalse130272.00
3646647132946NoneItem 9Providing and fixing meeting table consisting of 25 mm thick PLPB table top edge bounded, 25 mm thick PLPB with edge bonded End table, 18 mm thick PLPB with edge bonded Modesty, Hardware-Minifix assembly and screw leg, as per specifications, drawings and as directed by Engineer in charge. 2400 mm Dia x 1200 mm D x 750 mm Ht (12 seater)Type : Loose Furniture Table Top : 25mm thick E1 grade pre-laminated particle board table top with matching edgebanding and Alluminium Flipup Provision Of Size : 500mm(W) x 135mm(H) is Anodized Finish Considered. Understructure : Aluminium powder coated SOLE Legs (98 degree slant or 90 degree stright Legs) with die cast brackets and MS Powder coated 40x30mm beams are considered to support table top. Wire Management : MS-Powder coated wiretray with switch plate 150D/300D*120H and vertical cable risers are considered for wire management.GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo44929.6844929.681.0FalseNoneNoneFalseNoneFalse44929.680
3646648132946NoneItem 10DRINKING WATER COOLER : Providing and installing water cooler ss body and ss tank with specification Storage Capacity 80 Ltr, Normal cooling capacity 40Ltr, No of Faucets 2nos, Dimensions (MM) 665W x 480 D x 1210H, weight 47kg, Glasses Per hr 200Ltr, Refrigerant R-134a, current (amps)2.50, water over flow 1/2BSP, Typer of Compresser REIP. Including UV Corbon & Sediment filter of 250L PH water Purifier Fixing Seperatly duly connect. The rate to includ of water piping From OHT To Necessary drainage system for out let, angle cock system for as per specification. (GROUND FLOOR) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo47200.047200.03.0FalseNoneNoneFalseNoneFalse141600.00
3646649132946NoneItem 11PROVIDING ALL SAFE OFFICE LOCKER STEEL ALMIRAH (900X1800X600). depth with 5 shelves of 14 gauge powder coated the rate including one locker ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo11564.011564.010.0FalseNoneNoneFalseNoneFalse115640.00
17223352660000NoneNoneBuildingsTLH SHIRAHATTI WATER SUPPLY AND SANITATION WORKS15267245.72
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3646650132947NoneItem 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work:40mm dia pipes, From wash basin waste lines ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem369.48369.4875.0FalseNoneNoneFalseNoneFalse27711.00
3646651132947NoneItem 13.50.6Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work:50mm dia pipes, From sink & urinal waste lines ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem469.14469.1450.0FalseNoneNoneFalseNoneFalse23457.00
3646652132947NoneItem 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage):75mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem351.25351.25150.0FalseNoneNoneFalseNoneFalse52687.50
3646653132947NoneItem 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage):110mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem467.92467.9295.0FalseNoneNoneFalseNoneFalse44452.40
3646654132947NoneItem 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem239.43239.4350.0FalseNoneNoneFalseNoneFalse11971.50
3646655132947NoneItem 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem353.68353.68300.0FalseNoneNoneFalseNoneFalse106104.00
3646656132947NoneItem 13.49Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 150 mm diameter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem690.34690.3475.0FalseNoneNoneFalseNoneFalse51775.50
3646657132947NoneItem 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach296.55296.5530.0FalseNoneNoneFalseNoneFalse8896.50
3646658132947NoneItem 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (Shaft Drainage)75mm nominal dia pipes ((Shaft Drainage) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem351.25351.25350.0FalseNoneNoneFalseNoneFalse122937.50
3646659132947NoneItem 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (Shaft Drainage)110mm nominal dia pipes (Shaft Drainage) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem467.92467.92350.0FalseNoneNoneFalseNoneFalse163772.00
3646660132947NoneItem 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1482.781482.7820.0FalseNoneNoneFalseNoneFalse29655.60
3646661132947NoneItem 13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach753.54753.5458.0FalseNoneNoneFalseNoneFalse43705.320
3646662132947NoneItem 14.44Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting,of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach13641.6413641.644.0FalseNoneNoneFalseNoneFalse54566.560
3646663132947NoneItem 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7264.447264.4412.0FalseNoneNoneFalseNoneFalse87173.280
3646664132947NoneItem 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6176.666176.664.0FalseNoneNoneFalseNoneFalse24706.640
3646665132947NoneItem 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6828.116828.112.0FalseNoneNoneFalseNoneFalse13656.220
3646666132947NoneItem 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3745.863745.8620.0FalseNoneNoneFalseNoneFalse74917.20
3646667132947NoneItem 14.63aProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4578.414578.416.0FalseNoneNoneFalseNoneFalse27470.460
3646668132947NoneItem 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos881.16881.1615.0FalseNoneNoneFalseNoneFalse13217.40
3646669132947NoneItem 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach984.47984.4726.0FalseNoneNoneFalseNoneFalse25596.220
3646670132947NoneItem 13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach100.87100.8726.0FalseNoneNoneFalseNoneFalse2622.620
3646671132947NoneItem 14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach371.91371.9126.0FalseNoneNoneFalseNoneFalse9669.660
3646672132947NoneItem 14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach109.38109.3826.0FalseNoneNoneFalseNoneFalse2843.880
3646673132947NoneItem 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos77.7877.7850.0FalseNoneNoneFalseNoneFalse3889.00
3646674132947NoneItem 13.2.1Providing and fixing brass bib cock of approved quality:15 mm nominal bore ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos347.6347.620.0FalseNoneNoneFalseNoneFalse6952.00
3646675132947NoneItem 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5233.515233.515.0FalseNoneNoneFalseNoneFalse26167.550
3646676132947NoneItem 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc:15 mm nominal dia Pipes GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem375.55375.55100.0FalseNoneNoneFalseNoneFalse37555.00
3646677132947NoneItem 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc:20 mm nominal dia Pipes GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem460.63460.6385.0FalseNoneNoneFalseNoneFalse39153.550
3646678132947NoneItem 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc:25 mm nominal dia pipes GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem579.74579.74150.0FalseNoneNoneFalseNoneFalse86961.00
3646679132947NoneItem 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc:32 mm nominal dia pipes GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem676.97676.97100.0FalseNoneNoneFalseNoneFalse67697.00
3646680132947NoneItem 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall :40 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem651.45651.4575.0FalseNoneNoneFalseNoneFalse48858.750
3646681132947NoneItem 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall :50 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem949.22949.2230.0FalseNoneNoneFalseNoneFalse28476.60
3646682132947NoneItem 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Shafts & Terrace):25 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem359.75359.75175.0FalseNoneNoneFalseNoneFalse62956.250
3646683132947NoneItem 13.33.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Shafts & Terrace):32 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem452.12452.12150.0FalseNoneNoneFalseNoneFalse67818.00
3646684132947NoneItem 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Shafts & Terrace):40 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem579.74579.74300.0FalseNoneNoneFalseNoneFalse173922.00
3646685132947NoneItem 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Shafts & Terrace):50 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem876.3876.3500.0FalseNoneNoneFalseNoneFalse438150.00
3646686132947NoneItem 13.33.7Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Shafts & Terrace):65 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem1701.561701.56300.0FalseNoneNoneFalseNoneFalse510468.00
3646687132947NoneItem 13.33.8Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work(Shafts & Terrace):80 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2221.522221.52250.0FalseNoneNoneFalseNoneFalse555380.00
3646688132947NoneItem 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos403.51403.5120.0FalseNoneNoneFalseNoneFalse8070.20
3646689132947NoneItem 13.4.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos721.94721.9415.0FalseNoneNoneFalseNoneFalse10829.10
3646690132947NoneItem 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :40 mm nominal bore ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos853.21853.2112.0FalseNoneNoneFalseNoneFalse10238.520
3646691132947NoneItem 13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :50 mm nominal bore ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1039.161039.1612.0FalseNoneNoneFalseNoneFalse12469.920
3646692132947NoneItem 13.4.5Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :65 mm nominal bore ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1714.921714.9210.0FalseNoneNoneFalseNoneFalse17149.20
3646693132947NoneItem 13.4.6Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :80 mm nominal bore ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2524.382524.386.0FalseNoneNoneFalseNoneFalse15146.280
3646694132947NoneItem ELE7.3.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding.300 L Capacity ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach85060.9885060.984.0FalseNoneNoneFalseNoneFalse340243.920
3646695132947NoneItem 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg178.66178.66100.0FalseNoneNoneFalseNoneFalse17866.00
3646696132947NoneItem 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (FF Toilet ):40mm dia pipes, From wash basin waste lines ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem373.17373.1775.0FalseNoneNoneFalseNoneFalse27987.750
3646697132947NoneItem 13.50.6Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (FF Toilet ):50mm dia pipes, From sink & urinal waste lines ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem473.83473.8345.0FalseNoneNoneFalseNoneFalse21322.350
3646698132947NoneItem 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage)FF Toilet:75mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem354.76354.76120.0FalseNoneNoneFalseNoneFalse42571.20
3646699132947NoneItem 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage)FF Toilet:110mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem472.6472.685.0FalseNoneNoneFalseNoneFalse40171.00
3646700132947NoneItem 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach299.52299.5255.0FalseNoneNoneFalseNoneFalse16473.60
3646701132947NoneItem 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1497.611497.6125.0FalseNoneNoneFalseNoneFalse37440.250
3646702132947NoneItem 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos342.48342.488.0FalseNoneNoneFalseNoneFalse2739.840
3646703132947NoneItem 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6827.656827.658.0FalseNoneNoneFalseNoneFalse54621.20
3646704132947NoneItem 14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach608.86608.868.0FalseNoneNoneFalseNoneFalse4870.880
3646705132947NoneItem 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach177.99177.998.0FalseNoneNoneFalseNoneFalse1423.920
3646706132947NoneItem 13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach761.08761.0880.0FalseNoneNoneFalseNoneFalse60886.40
3646707132947NoneItem 14.44Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting,of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach13778.0613778.062.0FalseNoneNoneFalseNoneFalse27556.120
3646708132947NoneItem 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7337.097337.0914.0FalseNoneNoneFalseNoneFalse102719.260
3646709132947NoneItem 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6238.426238.4215.0FalseNoneNoneFalseNoneFalse93576.30
3646710132947NoneItem 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm) FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6896.396896.392.0FalseNoneNoneFalseNoneFalse13792.780
3646711132947NoneItem 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3783.323783.3215.0FalseNoneNoneFalseNoneFalse56749.80
3646712132947NoneItem 14.63aProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4624.194624.1917.0FalseNoneNoneFalseNoneFalse78611.230
3646713132947NoneItem 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos889.97889.9720.0FalseNoneNoneFalseNoneFalse17799.40
3646714132947NoneItem 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach994.31994.3132.0FalseNoneNoneFalseNoneFalse31817.920
3646715132947NoneItem 13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach101.88101.8832.0FalseNoneNoneFalseNoneFalse3260.160
3646716132947NoneItem 14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach375.63375.6332.0FalseNoneNoneFalseNoneFalse12020.160
3646717132947NoneItem 14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach110.47110.4732.0FalseNoneNoneFalseNoneFalse3535.040
3646718132947NoneItem 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos78.5678.5660.0FalseNoneNoneFalseNoneFalse4713.60
3646719132947NoneItem 13.2.1Providing and fixing brass bib cock of approved quality:15 mm nominal bore FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos351.08351.0815.0FalseNoneNoneFalseNoneFalse5266.20
3646720132947NoneItem 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.FF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5285.845285.8412.0FalseNoneNoneFalseNoneFalse63430.080
3646721132947NoneItem 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.FIRST FLOOR:15 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem379.31379.31100.0FalseNoneNoneFalseNoneFalse37931.00
3646722132947NoneItem 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.FIRST FLOOR:20 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem465.24465.24110.0FalseNoneNoneFalseNoneFalse51176.40
3646723132947NoneItem 1 3.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.FIRST FLOOR:25 mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem585.54585.5495.0FalseNoneNoneFalseNoneFalse55626.30
3646724132947NoneItem 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.FIRST FLOOR:32 mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem683.74683.7480.0FalseNoneNoneFalseNoneFalse54699.20
3646725132947NoneItem 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall :40 mm nominal dia Pipes FF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem657.96657.9685.0FalseNoneNoneFalseNoneFalse55926.60
3646726132947NoneItem 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 50 mm nominal dia Pipes FF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem958.71958.7150.0FalseNoneNoneFalseNoneFalse47935.50
3646727132947NoneItem 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work SF Toilet:40mm dia pipes, From wash basin waste lines ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem376.87376.8785.0FalseNoneNoneFalseNoneFalse32033.950
3646728132947NoneItem 13.50.6Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work SF Toilet:50mm dia pipes, From sink & urinal waste lines ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem478.52478.5255.0FalseNoneNoneFalseNoneFalse26318.60
3646729132947NoneItem 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) SF Toilet:75mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem358.27358.27165.0FalseNoneNoneFalseNoneFalse59114.550
3646730132947NoneItem 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) SF Toilet:110mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem477.28477.28110.0FalseNoneNoneFalseNoneFalse52500.80
3646731132947NoneItem 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach302.48302.4855.0FalseNoneNoneFalseNoneFalse16636.40
3646732132947NoneItem 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1512.441512.4425.0FalseNoneNoneFalseNoneFalse37811.00
3646733132947NoneItem 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos345.87345.878.0FalseNoneNoneFalseNoneFalse2766.960
3646734132947NoneItem 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6895.256895.258.0FalseNoneNoneFalseNoneFalse55162.00
3646735132947NoneItem 14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach614.89614.898.0FalseNoneNoneFalseNoneFalse4919.120
3646736132947NoneItem 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach179.75179.758.0FalseNoneNoneFalseNoneFalse1438.00
3646737132947NoneItem 13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach768.61768.6167.0FalseNoneNoneFalseNoneFalse51496.870
3646738132947NoneItem 14.44Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting,of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach13914.4813914.482.0FalseNoneNoneFalseNoneFalse27828.960
3646739132947NoneItem 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7409.737409.7314.0FalseNoneNoneFalseNoneFalse103736.220
3646740132947NoneItem 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6300.196300.196.0FalseNoneNoneFalseNoneFalse37801.140
3646741132947NoneItem 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm) SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6964.676964.673.0FalseNoneNoneFalseNoneFalse20894.010
3646742132947NoneItem 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3820.783820.7810.0FalseNoneNoneFalseNoneFalse38207.80
3646743132947NoneItem 14.63aProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4669.984669.989.0FalseNoneNoneFalseNoneFalse42029.820
3646744132947NoneItem 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos898.78898.7820.0FalseNoneNoneFalseNoneFalse17975.60
3646745132947NoneItem 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1004.161004.1619.0FalseNoneNoneFalseNoneFalse19079.040
3646746132947NoneItem 13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach102.89102.8919.0FalseNoneNoneFalseNoneFalse1954.910
3646747132947NoneItem 14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach379.35379.3519.0FalseNoneNoneFalseNoneFalse7207.650
3646748132947NoneItem 14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach111.57111.5719.0FalseNoneNoneFalseNoneFalse2119.830
3646749132947NoneItem 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos79.3479.3460.0FalseNoneNoneFalseNoneFalse4760.40
3646750132947NoneItem 13.2.1Providing and fixing brass bib cock of approved quality:15 mm nominal bore SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos354.55354.5515.0FalseNoneNoneFalseNoneFalse5318.250
3646751132947NoneItem 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. SF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5338.185338.1812.0FalseNoneNoneFalseNoneFalse64058.160
3646752132947NoneItem 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.SECOND FLOOR :15 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem383.06383.06125.0FalseNoneNoneFalseNoneFalse47882.50
3646753132947NoneItem 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.SECOND FLOOR20 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem469.84469.84110.0FalseNoneNoneFalseNoneFalse51682.40
3646754132947NoneItem 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.SECOND FLOOR:25 mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem591.34591.34105.0FalseNoneNoneFalseNoneFalse62090.70
3646755132947NoneItem 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.SECOND FLOOR:32 mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem690.51690.5195.0FalseNoneNoneFalseNoneFalse65598.450
3646756132947NoneItem 13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall Second Floor:40 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem664.48664.4885.0FalseNoneNoneFalseNoneFalse56480.80
3646757132947NoneItem 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall Second Floor:50 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem968.21968.2150.0FalseNoneNoneFalseNoneFalse48410.50
3646758132947NoneItem Data rateProviding, fixing, testing and commissioning of Air Vent Cowel 110mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos219.48219.4820.0FalseNoneNoneFalseNoneFalse4389.60
3646759132947NoneItem Data rateProviding, fixing, testing and commissioning of Air Vent Cowel 75mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos189.98189.9815.0FalseNoneNoneFalseNoneFalse2849.70
3646760132947NoneItem Data rateDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.Core cut-75mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1627.221627.2250.0FalseNoneNoneFalseNoneFalse81361.00
3646761132947NoneItem Data rateDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.Core cut-110mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2370.622370.62140.0FalseNoneNoneFalseNoneFalse331886.80
3646762132947NoneItem Data rateDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.Core cut-160mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2816.662816.6648.0FalseNoneNoneFalseNoneFalse135199.680
3646763132947NoneItem Data RateProviding, fixing, testing and commissioning CP grating for trap, complete as directed by the Engineer in charge & approved quality confiMing to ISI or BIS Standards ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos177.0177.0140.0FalseNoneNoneFalseNoneFalse24780.00
3646764132947NoneItem Data rateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent )(gf ff sf Toilet) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos9318.469318.4646.0FalseNoneNoneFalseNoneFalse428649.160
3646765132947NoneItem Data rateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. (Jaguar make or Equalent)(gf ff sf Toilet) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2183.02183.048.0FalseNoneNoneFalseNoneFalse104784.00
3646766132947NoneItem Market RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos767.0767.0100.0FalseNoneNoneFalseNoneFalse76700.00
3646767132947NoneItem Data RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized a) 32 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo3540.03540.012.0FalseNoneNoneFalseNoneFalse42480.00
3646768132947NoneItem Data RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized b) 50 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo5310.05310.015.0FalseNoneNoneFalseNoneFalse79650.00
3646769132947NoneItem Data RateSupplying, fixing and testing inlet, outlet, vent and over flow pipes, fittings with C.I frame with cover to over head tank complete with PVC rungs, etc complete as shown in the drawing. all puddle flanges to be hot dip galvanized c) 65 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo6844.06844.06.0FalseNoneNoneFalseNoneFalse41064.00
3646770132947NoneItem 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (EXTERNALWS) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum294.12294.12721.96FalseNoneNoneFalseNoneFalse212342.87520
3646771132947NoneItem 1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(EXTERNALWS) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum526.26526.26705.0FalseNoneNoneFalseNoneFalse371013.30
3646772132947NoneItem 10.3.7Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for(EXTERNALWS):Pipes of SN8 Self Fit - 160mm dia. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem749.9749.9600.0FalseNoneNoneFalseNoneFalse449940.00
3646773132947NoneItem 10.3.8Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for(EXTERNALWS):Pipes of SN8 Self Fit - 200mm dia. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem1081.71081.7100.0FalseNoneNoneFalseNoneFalse108170.00
3646774132947NoneItem 10.3.9Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for(EXTERNALWS):Pipes of SN8 Self Fit - 250mm dia. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem1662.661662.66100.0FalseNoneNoneFalseNoneFalse166266.00
3646775132947NoneItem 10.2.4Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for(EXTERNALWS):Pipes of SN4, 160mm dia. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem700.07700.07300.0FalseNoneNoneFalseNoneFalse210021.00
3646776132947NoneItem 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(EXTERNALWS) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6628.796628.7925.0FalseNoneNoneFalseNoneFalse165719.750
3646777132947NoneItem 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover..(CATCH BASIN)(EXTERNALWS) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6628.796628.7925.0FalseNoneNoneFalseNoneFalse165719.750
3646778132947NoneItem 13.39Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 150 x 100 mm size P type With Non Modular common burnt clay bricks of designation 3.5 & with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:(EXTERNALWS) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3136.943136.9442.0FalseNoneNoneFalseNoneFalse131751.480
3646779132947NoneItem 7.5.1Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete .(EXTERNAL WS)For DI/CI puddle flanges of 80mm dia. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1920.331920.338.0FalseNoneNoneFalseNoneFalse15362.640
3646780132947NoneItem 7.5.2Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete .(EXTERNAL WS)For DI/CI puddle flanges of 100mm dia. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2261.852261.856.0FalseNoneNoneFalseNoneFalse13571.10
3646781132947NoneItem 7.5.3Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete .(EXTERNAL WS)For DI/CI puddle flanges of 150mm dia. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2879.282879.282.0FalseNoneNoneFalseNoneFalse5758.560
3646782132947NoneItem 13.33.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work :50 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem876.3876.3600.0FalseNoneNoneFalseNoneFalse525780.00
3646783132947NoneItem 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work:65 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem1701.561701.56250.0FalseNoneNoneFalseNoneFalse425390.00
3646784132947NoneItem 21.1.11Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All Items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each componentsFor (For 2000 LPH FRP : Skid Type) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach748686.39748686.391.0FalseNoneNoneFalseNoneFalse748686.390
3646785132947NoneItem 20.8.1WATER TREATMENT PLANT Automatic Online Hydraulically Operated Self Cleaning Multi grade Pressure Filter for the flow rate of ........................... LPH (............... M.L.D) with 16 hour pumping NOTE : For Detailed Specification of Automatic hydraulic self cleaning screen filter(400 Microns), FILTRATION & Filter Media For Pressure Filter, Anthracite, Carbon . Detailed Specification and Rates fot Separate components ( i.e.., Online Sensore, Filtration & Filder media) of 10000 LPH to 225000 LPH Refer Annexure-C For 10000 & 15000 LPH (0.16 &0.24 M.L.D) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet1073198.21073198.21.0FalseNoneNoneFalseNoneFalse1073198.20
3646786132947NoneItem 13.40.1Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach18972.6218972.622.0FalseNoneNoneFalseNoneFalse37945.240
3646787132947NoneItem 13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all Items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeJob7900.097900.092.0FalseNoneNoneFalseNoneFalse15800.180
3646788132947NoneItem 13.40.3Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (DOMESTIC) 2 HP, Size 50x40 Head 22M, Discharge 186 LPM(NURSE'S QTRS,DOCTORS QTRS GROUP-D & MORTURY ) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach20653.3920653.398.0FalseNoneNoneFalseNoneFalse165227.120
3646789132947NoneItem 13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all Items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeJob7900.097900.098.0FalseNoneNoneFalseNoneFalse63200.720
3646790132947NoneItem Least QuotationSupplying, installing, testing and commissioning approved make centrifigal monoblock pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR & OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter, 10.0 Lps @ 45.0m Head (1 No. Working + 1No. Stand By) (From Domestic Water Sump to O.H.T) FOR HOSPITAL ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet354000.0354000.01.0FalseNoneNoneFalseNoneFalse354000.00
3646791132947NoneItem Least QuotationSupplying, installing, testing and commissioning approved make centrifigal monoblock pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR & OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter, 6.0 Lps @ 45.0m Head (1 No. Working + 1No. Stand By) (From STP to O.H.T) Flushing water. FOR HOSPITAL ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet295000.0295000.01.0FalseNoneNoneFalseNoneFalse295000.00
3646792132947NoneItem Least QuotationSupplying, installing, testing and commissioning approved make centrifigal monoblock pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR & OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter, 5cum/hr @ 35.0m Head (1 No. Working + 1No. Stand By) Raw water Transfer Pump ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet283200.0283200.01.0FalseNoneNoneFalseNoneFalse283200.00
3646793132947NoneItem Data RateSupply installation testing & commissioning of Air source Heat pump of hot water output of 600 lt/hr, with imported primary circulation pump, compressor, heat exchanger, expansion valve, evaporator, fan, solenoid valve , high pressure switch & low pressure switch, Hot water storage tank of 1000lt capacity, made up of MS CRCA sheets of 5/6 mm thick manhole of 450mm ID, all nozzles, tank inside heat resistant epoxy, external with primer and enamel paint, tank insulation with Rockwool insulation and aluminum cladding of 24swg, Hot water connections from heat pump to mixing tank, with necessary SS ball valves, NRV, air vent, MS ERW C class pipes, bends, flanges etc. with required thermal insulation, testing points for maintenance etc, Return water pump( building circulation pump) of 1 m3 with 20mt head, 1 working, with timer control and temperature with control panel with contactors, OLRs, MCBs, etc .. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1212780.41212780.41.0FalseNoneNoneFalseNoneFalse1212780.40
3646794132947NoneItem 1.4.2Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m RECHARGE PIT 1000 MM Dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum314.78314.7816.9668FalseNoneNoneFalseNoneFalse5340.8093040
3646795132947NoneItem data rateLoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) RECHARGE PIT 1000 MM Dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum164.07164.0733.9336FalseNoneNoneFalseNoneFalse5567.4857520
3646796132947NoneItem 17.5Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.RECHARGE PIT 1000 MM Dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1364.891364.8970.0FalseNoneNoneFalseNoneFalse95542.30
3646797132947NoneItem 17.1Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.RECHARGE PIT 1000 MM Dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1217.831217.832.8278FalseNoneNoneFalseNoneFalse3443.7796740
3646798132947NoneItem 17.2Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.RECHARGE PIT 1000 MM Dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1441.461441.461.4139FalseNoneNoneFalseNoneFalse2038.0802940
3646799132947NoneItem 17.3Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.RECHARGE PIT 1000 MM Dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1448.751448.751.4139FalseNoneNoneFalseNoneFalse2048.3876250
3646800132947NoneItem 17.4Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.RECHARGE PIT 1000 MM Dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum1627.421627.421.4139FalseNoneNoneFalseNoneFalse2301.0091380
3646801132947NoneItem 17.14Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.RECHARGE PIT 1000 MM Dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1422.011422.0110.0FalseNoneNoneFalseNoneFalse14220.10
3646802132947NoneItem 16.18.6Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:Constructing Pre-cast RCC Machinehole 1.2 m internal dia. ,3.0M depth & SFRC cover & frame ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo95394.3195394.318.0FalseNoneNoneFalseNoneFalse763154.480
17223352660000NoneNoneBuildingsTLH electrical works37181153.08
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3646803132948NoneItem 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint326.94326.94188.0FalseNoneNoneFalseNoneFalse61464.720
3646804132948NoneItem 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint460.63460.63300.0FalseNoneNoneFalseNoneFalse138189.00
3646805132948NoneItem 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint674.54674.54600.0FalseNoneNoneFalseNoneFalse404724.00
3646806132948NoneItem 2.2.4Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint822.82822.8250.0FalseNoneNoneFalseNoneFalse41141.00
3646807132948NoneItem 2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint1202.031202.0325.0FalseNoneNoneFalseNoneFalse30050.750
3646808132948NoneItem 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach167.72167.72150.0FalseNoneNoneFalseNoneFalse25158.00
3646809132948NoneItem 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach193.24193.24200.0FalseNoneNoneFalseNoneFalse38648.00
3646810132948NoneItem 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach215.12215.1250.0FalseNoneNoneFalseNoneFalse10756.00
3646811132948NoneItem 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach267.38267.3875.0FalseNoneNoneFalseNoneFalse20053.50
3646812132948NoneItem 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach317.21317.21140.0FalseNoneNoneFalseNoneFalse44409.40
3646813132948NoneItem 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach387.71387.71250.0FalseNoneNoneFalseNoneFalse96927.50
3646814132948NoneItem 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach166.5166.5150.0FalseNoneNoneFalseNoneFalse24975.00
3646815132948NoneItem 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.67195.67200.0FalseNoneNoneFalseNoneFalse39134.00
3646816132948NoneItem 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach212.69212.6950.0FalseNoneNoneFalseNoneFalse10634.50
3646817132948NoneItem 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach284.4284.475.0FalseNoneNoneFalseNoneFalse21330.00
3646818132948NoneItem 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach345.17345.17140.0FalseNoneNoneFalseNoneFalse48323.80
3646819132948NoneItem 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach418.09418.09250.0FalseNoneNoneFalseNoneFalse104522.50
3646820132948NoneItem 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach123.97123.971807.0FalseNoneNoneFalseNoneFalse224013.790
3646821132948NoneItem 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach201.75201.7512.0FalseNoneNoneFalseNoneFalse2421.00
3646822132948NoneItem 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach207.83207.83650.0FalseNoneNoneFalseNoneFalse135089.50
3646823132948NoneItem 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach433.89433.89230.0FalseNoneNoneFalseNoneFalse99794.70
3646824132948NoneItem 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach396.22396.22100.0FalseNoneNoneFalseNoneFalse39622.00
3646825132948NoneItem 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach286.83286.83250.0FalseNoneNoneFalseNoneFalse71707.50
3646826132948NoneItem 3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach218.77218.77150.0FalseNoneNoneFalseNoneFalse32815.50
3646827132948NoneItem 1.13Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo142.2142.2230.0FalseNoneNoneFalseNoneFalse32706.00
3646828132948NoneItem 5.45.2Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. SP & N 20Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1180.151180.155.0FalseNoneNoneFalseNoneFalse5900.750
3646829132948NoneItem 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach504.39504.39588.0FalseNoneNoneFalseNoneFalse296581.320
3646830132948NoneItem 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach10315.0910315.092.0FalseNoneNoneFalseNoneFalse20630.180
3646831132948NoneItem 5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE250Amps 25kA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach25998.6225998.621.0FalseNoneNoneFalseNoneFalse25998.620
3646832132948NoneItem 5.18.7Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2086.842086.8419.0FalseNoneNoneFalseNoneFalse39649.960
3646833132948NoneItem 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 63Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3753.153753.1531.0FalseNoneNoneFalseNoneFalse116347.650
3646834132948NoneItem 1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr80.2280.226500.0FalseNoneNoneFalseNoneFalse521430.00
3646835132948NoneItem 1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr94.894.89200.0FalseNoneNoneFalseNoneFalse872160.00
3646836132948NoneItem 1.2.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr125.18125.182000.0FalseNoneNoneFalseNoneFalse250360.00
3646837132948NoneItem 1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr82.6482.642800.0FalseNoneNoneFalseNoneFalse231392.00
3646838132948NoneItem 1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr96.0196.014500.0FalseNoneNoneFalseNoneFalse432045.00
3646839132948NoneItem 1.3.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr120.32120.321000.0FalseNoneNoneFalseNoneFalse120320.00
3646840132948NoneItem 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr31.631.67500.0FalseNoneNoneFalseNoneFalse237000.00
3646841132948NoneItem 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr51.0551.0520000.0FalseNoneNoneFalseNoneFalse1021000.00
3646842132948NoneItem 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr76.5776.579000.0FalseNoneNoneFalseNoneFalse689130.00
3646843132948NoneItem 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr111.81111.816200.0FalseNoneNoneFalseNoneFalse693222.00
3646844132948NoneItem 2.3.6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr202.97202.97300.0FalseNoneNoneFalseNoneFalse60891.00
3646845132948NoneItem 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4907.784907.7815.0FalseNoneNoneFalseNoneFalse73616.70
3646846132948NoneItem 5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6004.076004.0715.0FalseNoneNoneFalseNoneFalse90061.050
3646847132948NoneItem 5.19.13Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 8 Way TP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7403.07403.02.0FalseNoneNoneFalseNoneFalse14806.00
3646848132948NoneItem 5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2830.662830.664.0FalseNoneNoneFalseNoneFalse11322.640
3646849132948NoneItem 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach898.18898.1810.0FalseNoneNoneFalseNoneFalse8981.80
3646850132948NoneItem 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3699.673699.6744.0FalseNoneNoneFalseNoneFalse162785.480
3646851132948NoneItem 5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6255.666255.6632.0FalseNoneNoneFalseNoneFalse200181.120
3646852132948NoneItem 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5198.265198.264.0FalseNoneNoneFalseNoneFalse20793.040
3646853132948NoneItem 32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm143422.06143422.060.15FalseNoneNoneFalseNoneFalse21513.3090
3646854132948NoneItem 32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm107463.23107463.230.2FalseNoneNoneFalseNoneFalse21492.6460
3646855132948NoneItem 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm169607.85169607.850.15FalseNoneNoneFalseNoneFalse25441.17750
3646856132948NoneItem 32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm187246.95187246.950.1FalseNoneNoneFalseNoneFalse18724.6950
3646857132948NoneItem 32.111.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 50 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm217523.78217523.780.2FalseNoneNoneFalseNoneFalse43504.7560
3646858132948NoneItem 32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm386390.24386390.240.2FalseNoneNoneFalseNoneFalse77278.0480
3646859132948NoneItem 32.141.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 95 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm453605.51453605.510.05FalseNoneNoneFalseNoneFalse22680.27550
3646860132948NoneItem 32.171.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 185 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm840106.35840106.350.06FalseNoneNoneFalseNoneFalse50406.3810
3646861132948NoneItem 32.181.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 240 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm1048484.251048484.250.1FalseNoneNoneFalseNoneFalse104848.4250
3646862132948NoneItem 32.191.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 300 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm1295633.411295633.410.2FalseNoneNoneFalseNoneFalse259126.6820
3646863132948NoneItem 21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm25384.8425384.840.5FalseNoneNoneFalseNoneFalse12692.420
3646864132948NoneItem 21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm37846.3437846.340.55FalseNoneNoneFalseNoneFalse20815.4870
3646865132948NoneItem 21.07Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 120 sqmm to 300 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm39230.6839230.680.85FalseNoneNoneFalseNoneFalse33346.0780
3646866132948NoneItem 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach142.2142.26.0FalseNoneNoneFalseNoneFalse853.20
3646867132948NoneItem 6.11.5Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 50mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach320.86320.8610.0FalseNoneNoneFalseNoneFalse3208.60
3646868132948NoneItem 6.11.5Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 75mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach623.5623.510.0FalseNoneNoneFalseNoneFalse6235.00
3646869132948NoneItem 6.11.6Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 63mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach471.57471.575.0FalseNoneNoneFalseNoneFalse2357.850
3646870132948NoneItem 6.17.5Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach9.729.7216.0FalseNoneNoneFalseNoneFalse155.520
3646871132948NoneItem 6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach15.1115.1116.0FalseNoneNoneFalseNoneFalse241.760
3646872132948NoneItem 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach38.8938.8924.0FalseNoneNoneFalseNoneFalse933.360
3646873132948NoneItem 6.17.9Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 50 sqmm Long Barrel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach72.9272.9232.0FalseNoneNoneFalseNoneFalse2333.440
3646874132948NoneItem 6.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach145.84145.8440.0FalseNoneNoneFalseNoneFalse5833.60
3646875132948NoneItem 6.17.11Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 95 sqmm Long Barrel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach182.31182.318.0FalseNoneNoneFalseNoneFalse1458.480
3646876132948NoneItem 6.17.14Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 185 sqmm Long Barrel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach397.43397.438.0FalseNoneNoneFalseNoneFalse3179.440
3646877132948NoneItem 6.17.15Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 240 sqmm Long Barrel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach562.73562.738.0FalseNoneNoneFalseNoneFalse4501.840
3646878132948NoneItem 6.17.16Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 300 sqmm Long Barrel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach762.05762.0524.0FalseNoneNoneFalseNoneFalse18289.20
3646879132948NoneItem 12.59.1Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary Gl bolts/nuts and washer or welding as required 150x50mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr562.73562.73500.0FalseNoneNoneFalseNoneFalse281365.00
3646880132948NoneItem 12.59.3Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary Gl bolts/nuts and washer or welding as required 450x50mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr1109.661109.6650.0FalseNoneNoneFalseNoneFalse55483.00
3646881132948NoneItem 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo4266.054266.0514.0FalseNoneNoneFalseNoneFalse59724.70
3646882132948NoneItem 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr99.6699.66150.0FalseNoneNoneFalseNoneFalse14949.00
3646883132948NoneItem 12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr155.57155.57150.0FalseNoneNoneFalseNoneFalse23335.50
3646884132948NoneItem 12.58.4Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm GI strip ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr219.98219.9830.0FalseNoneNoneFalseNoneFalse6599.40
3646885132948NoneItem 12.58.6Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600 X 600 X 3 mm GI plate. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr1063.41063.44.0FalseNoneNoneFalseNoneFalse4253.60
3646886132948NoneItem 12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper strip ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr692.77692.7780.0FalseNoneNoneFalseNoneFalse55421.60
3646887132948NoneItem 12.58.8Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm Copper strip ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr1336.931336.9380.0FalseNoneNoneFalseNoneFalse106954.40
3646888132948NoneItem 12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr1996.91996.920.0FalseNoneNoneFalseNoneFalse39938.00
3646889132948NoneItem 12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 600x600x3mm Copper plate ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach9019.489019.4810.0FalseNoneNoneFalseNoneFalse90194.80
3646890132948NoneItemSupply and installation of Bedded Panel with 4 no's 6 amps sockets and 2 no's 16 amps sockets with switches and 6 watt LED light fixtures & Provision for 4Nos gas pipeline sockets. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach10330.910330.915.0FalseNoneNoneFalseNoneFalse154963.50
3646891132948NoneItem 11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1075.621075.6260.0FalseNoneNoneFalseNoneFalse64537.20
3646892132948NoneItem 11.5.3Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 18W ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1609.181609.1835.0FalseNoneNoneFalseNoneFalse56321.30
3646893132948NoneItem 11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach838.62838.62600.0FalseNoneNoneFalseNoneFalse503172.00
3646894132948NoneItem 11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach181.09181.0920.0FalseNoneNoneFalseNoneFalse3621.80
3646895132948NoneItem 11.11.5Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach326.94326.9475.0FalseNoneNoneFalseNoneFalse24520.50
3646896132948NoneItem 11.6.3Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 34 36watt ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5533.715533.71170.0FalseNoneNoneFalseNoneFalse940730.70
3646897132948NoneItem 11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70watts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo7282.677282.6710.0FalseNoneNoneFalseNoneFalse72826.70
3646898132948NoneItem 11.15Supplying and fixing of LED Bulkhead of 10W with IP65 protection and IK 08 impact resistance suitable for surface and wall mounting applications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1023.361023.3610.0FalseNoneNoneFalseNoneFalse10233.60
3646899132948NoneItem 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1813.371813.3740.0FalseNoneNoneFalseNoneFalse72534.80
3646900132948NoneItem 6.2.2Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 15" Sweep (450mm) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5014.745014.745.0FalseNoneNoneFalseNoneFalse25073.70
3646901132948NoneItem 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3253.623253.62230.0FalseNoneNoneFalseNoneFalse748332.60
3646902132948NoneItem 6.5.1Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply. 300mm Sweep ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3028.773028.778.0FalseNoneNoneFalseNoneFalse24230.160
3646903132948NoneItem 12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach76.5776.5795.0FalseNoneNoneFalseNoneFalse7274.150
3646904132948NoneItem 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach148.27148.27865.0FalseNoneNoneFalseNoneFalse128253.550
3646905132948NoneItem 13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach382.85382.85238.0FalseNoneNoneFalseNoneFalse91118.30
3646906132948NoneItem 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach859.28859.2845.0FalseNoneNoneFalseNoneFalse38667.60
3646907132948NoneItem 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1775.691775.6910.0FalseNoneNoneFalseNoneFalse17756.90
3646908132948NoneItem 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach196.89196.8910.0FalseNoneNoneFalseNoneFalse1968.90
3646909132948NoneItem 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach298.98298.9815.0FalseNoneNoneFalseNoneFalse4484.70
3646910132948NoneItem 5.42.1Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.610.611490000.0FalseNoneNoneFalseNoneFalse908900.00
3646911132948NoneItem 5.40.5Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 1000 A double run of 4 x 60 x 10 mm Aluminium Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr12858.9312858.9315.0FalseNoneNoneFalseNoneFalse192883.950
3646912132948NoneItem 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr674.54674.5430.0FalseNoneNoneFalseNoneFalse20236.20
3646913132948NoneItem 5.41.5Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x150x75x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr1125.461125.4630.0FalseNoneNoneFalseNoneFalse33763.80
3646914132948NoneItem 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach10315.0910315.097.0FalseNoneNoneFalseNoneFalse72205.630
3646915132948NoneItem 5.15.10Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA125Amps 25kA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach12568.4512568.453.0FalseNoneNoneFalseNoneFalse37705.350
3646916132948NoneItem 5.15.13Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA 250Amps 35kA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach25998.6225998.621.0FalseNoneNoneFalseNoneFalse25998.620
3646917132948NoneItem 5.15.17Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Therm IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE320-400Amps 50kA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach36596.936596.91.0FalseNoneNoneFalseNoneFalse36596.90
3646918132948NoneItem 5.15.20Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Therm IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE700-800Amps 50kA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach60648.4660648.461.0FalseNoneNoneFalseNoneFalse60648.460
3646919132948NoneItem ARSupply and fixing of 800Amps fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,.Adjustable Time Delay(0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 Volts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3646920132948NoneItem 5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach11248.5211248.522.0FalseNoneNoneFalseNoneFalse22497.040
3646921132948NoneItem 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach11321.411321.48.0FalseNoneNoneFalseNoneFalse90571.20
3646922132948NoneItem 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach625.93625.9337.0FalseNoneNoneFalseNoneFalse23159.410
3646923132948NoneItem 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach683.05683.0520.0FalseNoneNoneFalseNoneFalse13661.00
3646924132948NoneItem 5.16Suppiying and fixing of Shunt trip suitable for MCCB.CBCT ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2069.822069.822.0FalseNoneNoneFalseNoneFalse4139.640
3646925132948NoneItem 5.36Supplying,fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1020.931020.9312.0FalseNoneNoneFalseNoneFalse12251.160
3646926132948NoneItem 5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.520.521310000.0FalseNoneNoneFalseNoneFalse681200.00
3646927132948NoneItem 5.40.3Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 400Amps 4x50x10mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr5402.455402.455.0FalseNoneNoneFalseNoneFalse27012.250
3646928132948NoneItem 5.41.2Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x50x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr480.08480.0816.0FalseNoneNoneFalseNoneFalse7681.280
3646929132948NoneItem 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr918.84918.8466.0FalseNoneNoneFalseNoneFalse60643.440
3646930132948NoneItem 5.15.17Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Therm IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 320-400Amps 50kA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach36596.936596.91.0FalseNoneNoneFalseNoneFalse36596.90
3646931132948NoneItem 5.39Supplying, fixing and wiring Automatic Power Factor controller fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three place LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect I disconnect banks, with automatic recognition or with standard programs. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach26301.2526301.251.0FalseNoneNoneFalseNoneFalse26301.250
3646932132948NoneItem 5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKvar583.39583.39150.0FalseNoneNoneFalseNoneFalse87508.50
3646933132948NoneItem 5.13.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1567.861567.863.0FalseNoneNoneFalseNoneFalse4703.580
3646934132948NoneItem 5.13.2Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 40 Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2744.372744.374.0FalseNoneNoneFalseNoneFalse10977.480
3646935132948NoneItem 5.15.10Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 125Amps 25kA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach12568.4512568.452.0FalseNoneNoneFalseNoneFalse25136.90
3646936132948NoneItem 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach10315.0910315.096.0FalseNoneNoneFalseNoneFalse61890.540
3646937132948NoneItem 5.15.10Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 125Amps 25kA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach12568.4512568.451.0FalseNoneNoneFalseNoneFalse12568.450
3646938132948NoneItem 5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x10mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr2995.962995.9616.0FalseNoneNoneFalseNoneFalse47935.360
3646939132948NoneItem 5.2.1Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired ajter fixing to the existing wooden board for motor Upto 12.5 HP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach9060.89060.86.0FalseNoneNoneFalseNoneFalse54364.80
3646940132948NoneItem market rateSTREET LIGHTING PANEL-Fabricating, Supplying & Mounting M.S. Box made out of 16 SWG of size 700x750x220mm suitable for floor / wall mounting, fully weather proof with provision for better heat desipation, with two chambers & window for energy meter, provided with hinged front cover, two inside doors, with tamper proof locking arrangments, suitable size clamps with necessary cable entry pipe with gland and box should be finished with two coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. The box should be mounted on M.S.angle iron of size 40x40x6mm (total length 4.7 mtr) with 1:2:4 concreting (0.25x0.75x0.9 mtr) including coping. provision for housing 3 phase energy meter, suitable size bus bar, 100 A cut out (3 Nos), with timer (3-120sec) & contactorc) (60-70Amps), 63 A MCB TPN (1 No), 2 Nos 32 A TPN MCB on 4mm thick hylum sheet, wiring with suitable size copper wire & lugs. The box should be earthed with pipe type earthing. (AS PER PWD SR) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet35400.035400.01.0FalseNoneNoneFalseNoneFalse35400.00
3646941132948NoneItem 4.1.1Fabricating, supplying and erecting swaged tubular pole of height …Mtr having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the pole(as per IS) and 40mm dia GI / flexible PVC pipe of 1 mtr length fitted to the heavy gauge polycarbonate control box including 5way connector of size 167x125x82mm for 7.5M pole/200x160x98mm for remaining length of pole with front opening cover, with locking arrangements and suitable capacity MCB / DP switch, The pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the pole to the ground level and the coping CC shall be up to 0.6M above ground level as per IS 2713 - 7. Erection of heavy duty pole on Footpath / median 9Mt (5Mt Hb,165.1mm dia 4.85mm thick x2M Hm, 139.7mm dia 4.50mm thick x 2M Ht,114.3mm dia 3.65mm thick) as per IS 410 SP 32 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach18838.718838.710.0FalseNoneNoneFalseNoneFalse188387.00
3646942132948NoneItem 11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70watts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo7282.677282.6710.0FalseNoneNoneFalseNoneFalse72826.70
3646943132948NoneItem 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1775.691775.6915.0FalseNoneNoneFalseNoneFalse26635.350
3646944132948NoneItem 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach196.89196.8925.0FalseNoneNoneFalseNoneFalse4922.250
3646945132948NoneItem 32.021.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm96298.5796298.570.25FalseNoneNoneFalseNoneFalse24074.64250
3646946132948NoneItem 32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 10 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm143422.06143422.060.5FalseNoneNoneFalseNoneFalse71711.030
3646947132948NoneItem 31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm25384.8425384.840.75FalseNoneNoneFalseNoneFalse19038.630
3646948132948NoneItem 6.7.1Supplying of…TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube.(High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 Star 1 ton capacity ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach50689.4750689.475.0FalseNoneNoneFalseNoneFalse253447.350
3646949132948NoneItem 6.7.3Supplying of…TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube.(High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 Star 2 ton capacity ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach65689.9365689.939.0FalseNoneNoneFalseNoneFalse591209.370
3646950132948NoneItem 6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 ton split/cassette type A/C. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3858.893858.8914.0FalseNoneNoneFalseNoneFalse54024.460
3646951132948NoneItem 9.1.1Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v in put and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. 3 KVA Capacity ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5824.195824.195.0FalseNoneNoneFalseNoneFalse29120.950
3646952132948NoneItem 9.1.2Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v in put and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. 4 KVA Capacity ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5824.195824.199.0FalseNoneNoneFalseNoneFalse52417.710
3646953132948NoneItem 6.9.2Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run, relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit. 3.0 TR Cassette 3 Ph ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach127759.2127759.26.0FalseNoneNoneFalseNoneFalse766555.20
3646954132948NoneItem 6.13.2Supplying and installation of insulated refrigerant copper tubing of 5/8 and 3/8 with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit. Leak testing oil and gas charging for additional piping length of tube. Cassette ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1992.041992.04200.0FalseNoneNoneFalseNoneFalse398408.00
3646955132948NoneItem 6.22Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5842.425842.4225.0FalseNoneNoneFalseNoneFalse146060.50
3646956132948None1Item 4.4.6Design, supplying, erecting testing and commissioning of - 20Passenger/ Bed-cum-passenger hospital lift(3 stops/3 Opening) with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665/2016 ( with latest amendments) part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3504618.023504618.022.0FalseNoneNoneFalseNoneFalse7009236.040
3646957132948NoneItem Least Quotation RateSupply, Installation Testing and commissioning of double convertsion, DSP Based, True on line 2 x20KVA UPS system with 415V +/- 15% V,50Hz,3Ph Input & 415V+/-1%, 50 Hz ,3Ph Output, With Output 0.9 PF, working on 16 Bit microprocessor Architecture,Isolation transformers, RS 232 ports, monitoring software , O/L, SC. protections & self diagnostic features, LCD Display Panel for Functions & all parameters, complying with IEC standards. Convertors, Invertors & Battery Charger shall utilize PWM technology with IGBT. Battery Back up time of 15 minutes back up on 40kva load with required VRLA SMF individual Battery bank System(65AH-32 Nos each Battery Bank) housed in suitable Cabinet /Rack, Static ByPass, complete with Internal wiring & all accessories to be provided. The System shall have in-built P.F.correction & shall ensure THD as per latest International standards. The efficiency of UPS shall be 96% or more. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1062000.01062000.01.0FalseNoneNoneFalseNoneFalse1062000.00
3646958132948NoneItem 3.6.13RJ45/ I.O. outlet Cat 6 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach409.58409.5870.0FalseNoneNoneFalseNoneFalse28670.60
3646959132948NoneItem 3.6.12Telephone socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.6189.670.0FalseNoneNoneFalseNoneFalse13272.00
3646960132948NoneItem 8.1Supplying and drawing UTP-CAT 6E LAN cable. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr46.1846.182600.0FalseNoneNoneFalseNoneFalse120068.00
3646961132948NoneItem 8.10.1Supplying & Fixing of I/O Socket with back box Single I/O ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach595.54595.5470.0FalseNoneNoneFalseNoneFalse41687.80
3646962132948NoneItem 8.4.3Supplying & Fixing of switch mounting rack with power manager & Cable manager as per standard specification 9U with 450mm depth ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach10301.7310301.733.0FalseNoneNoneFalseNoneFalse30905.190
3646963132948NoneItem 8.9.5Supplying fixing of Network Switches. 24 port 10/100 Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5712.385712.383.0FalseNoneNoneFalseNoneFalse17137.140
3646964132948NoneItem 8.11.2Supplying & fixing of ..mtrs. Cat 6Patch Cable. 2Mtr ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach312.35312.3570.0FalseNoneNoneFalseNoneFalse21864.50
3646965132948NoneItem 8.12.2Supplying & Fixing of Patch panel for Lan Cabling. 24 Port 10/100 patch panel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3706.973706.973.0FalseNoneNoneFalseNoneFalse11120.910
3646966132948NoneItem 8.2.2Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr25.5225.522100.0FalseNoneNoneFalseNoneFalse53592.00
3646967132948NoneItem 8.2.5Supplying and drawing PVC flexible 5 pair telepone unarmoured tinned copper cable. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr55.955.9100.0FalseNoneNoneFalseNoneFalse5590.00
3646968132948NoneItem 8.2.6Supplying and drawing PVC flexible 10 pair telepone unarmoured tinned copper cable. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr98.4498.44150.0FalseNoneNoneFalseNoneFalse14766.00
3646969132948NoneItem 8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 20 Pair ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach465.49465.494.0FalseNoneNoneFalseNoneFalse1861.960
3646970132948NoneItem Least Quotation RateSupplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 50 Pair ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1770.01770.01.0FalseNoneNoneFalseNoneFalse1770.00
3646971132948NoneItem Least Quotation RateSupply, Installtion, Testing and Comissioning of IP PBX with 550 SIP Extensions, up to 100 Concurrent Calls Redundant Power Supplies with Hot Swappable Interfaces Boards (FXS/FXO/E1/T1) and IP/SIP Failover with features of Multiple SIP Trunks and Flexible Routing and Support audio codec G.722 and Opus, HD audio on speakerphone and handset ---- etc., complete including all lead and lift and work to be executed as per the specification and engineer -in-charge of the work ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos100300.0100300.01.0FalseNoneNoneFalseNoneFalse100300.00
3646972132948NoneItem Least Quotation RateTELEPHONES Analog push button telephone with Caller ID, flash and radial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2124.02124.070.0FalseNoneNoneFalseNoneFalse148680.00
3646973132948NoneItem Least Quotation RateSupply, Installation, Testing and Commissioning of Line Interface Unit-6 Port LIU with Coupler and Connector SM Type ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos8850.08850.02.0FalseNoneNoneFalseNoneFalse17700.00
3646974132948NoneItem Least Quotation RateSupply, Installation, Testing and Commissioning of 6-core OFC - Armoured outdoor cable (SM) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr115.64115.64150.0FalseNoneNoneFalseNoneFalse17346.00
3646975132948NoneItem 1.2.2Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr94.894.83200.0FalseNoneNoneFalseNoneFalse303360.00
3646976132948NoneItem Least Quotation RateIP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach23836.023836.018.0FalseNoneNoneFalseNoneFalse429048.00
3646977132948NoneItem Least Quotation RateIP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach25606.025606.08.0FalseNoneNoneFalseNoneFalse204848.00
3646978132948NoneItem Least Quotation RateSupplying, installation, testing and commissioning of SITC of complete 32 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach271400.0271400.01.0FalseNoneNoneFalseNoneFalse271400.00
3646979132948NoneItem Least Quotation RateSupply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach17110.017110.06.0FalseNoneNoneFalseNoneFalse102660.00
3646980132948NoneItem Least Quotation RateSupply and Installation of 16 Port L2 Managed Poe Switch The rate shall include all mounting accessories complete as required ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach47495.047495.03.0FalseNoneNoneFalseNoneFalse142485.00
3646981132948NoneItem Least Quotation RateSupply and Installation of I/Os ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach147.5147.526.0FalseNoneNoneFalseNoneFalse3835.00
3646982132948NoneItem Least Quotation RateSupply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach265.5265.526.0FalseNoneNoneFalseNoneFalse6903.00
3646983132948NoneItem Least Quotation RateSupply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach336.29336.2926.0FalseNoneNoneFalseNoneFalse8743.540
3646984132948NoneItem Least Quotation RateSupply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
3646985132948NoneItem 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr46.1846.182200.0FalseNoneNoneFalseNoneFalse101596.00
3646986132948NoneItem 1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr94.894.82000.0FalseNoneNoneFalseNoneFalse189600.00
3646987132948NoneItem 8.12.2Supplying & Fixing of Patch panel for LAN cabling .24 Port 10/100 patch panel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4983.134983.133.0FalseNoneNoneFalseNoneFalse14949.390
3646988132948NoneItem 8.4.4Supplying & Fixing of switch mounting rack with power manager & Cable manager 12U with 450mm depth ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach10738.0510738.053.0FalseNoneNoneFalseNoneFalse32214.150
3646989132948NoneItem 3.6.11TV socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.6189.610.0FalseNoneNoneFalseNoneFalse1896.00
3646990132948NoneItem Least Quotation RateThe Scope of work is Supply,istallation, Testing for T.V. System with following Items & components in Rooms & other Specific Areas. It also covers co-ordination with T.V service provider for completeness & usage of the Items /components erected by Vendor.Booster amplifier. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3540.03540.04.0FalseNoneNoneFalseNoneFalse14160.00
3646991132948NoneItem Least Quotation RateThe Scope of work is Supply,istallation, Testing for T.V. System with following Items & components in Rooms & other Specific Areas. It also covers co-ordination with T.V service provider for completeness & usage of the Items /components erected by Vendor. 3 way splitter. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach236.0236.06.0FalseNoneNoneFalseNoneFalse1416.00
3646992132948NoneItem 8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr53.4753.47550.0FalseNoneNoneFalseNoneFalse29408.50
3646993132948NoneItem Least Quotation RateSupply, installation, testing and commissioning of 'The Bedside call unit shall be mounted on the head boards where there are patient headboards or on the walls where it can be implemented within the system.'The Bedside call unit shall be 2 input\output ports for RJ45 Endings for cabling in a chain with overdoor lights and other call units and eventually to one zone controller. 'On the standard bedside call unit front side there shall be: 'An "End Call" Button with a green tick mark symbol.'Reassurance backlight in order to give visual information about call ststus.'Continous backlight for easy visibility of the unit at night.'Pressing on the end call button ends the call and turns the assigned overdoor light to green. IP System controller logs the event as "Presence"'Pressing the end call button for the second time ends the "presence" and turns off the assigned overdoor light.'The Bedside Call Unit shall made from noninflammable PC-ABS-FR Materials.'It can be used individually as a call button where patient handset is not needed. Other wise, its connection with the patient handset shall be easily established ny the connecting via RJ45 on its front side.'A Nurse call shall be initated via the patient handset or the bedside call unit. These two buttons shall be accepted by the system as equivalent. In the event that these buttons are pressed.'If the unit is ablee to transmit the call to the zone controller, the LED on the unit shall flash with 1.0 second intervals, call transmission information shall be audibly notified to the patient.'If there is an error in the call transmission, a continuous red light showing error status shall only stop when the call termination button is pressed, subsequent presses of the button shall trigger an audio alert each time.'Its connection shall be made with cat 6 UTP Cable RJ45 of B Standard.'This device shall be powered by the Zone Controller. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos4130.04130.080.0FalseNoneNoneFalseNoneFalse330400.00
3646994132948NoneItem Least Quotation RateSupply, installation, testing and commissioning of PATIENT HANDSET BASIC.This Handset will be used in the locations that are connected to the system by a zone controller.'It Shall be ergonomically suitable to be handheld.'It shall be connected to the bedside call unit with an independent cable.'on its front side there shall be 'A "start Call" Button with red nurse symbol.'Reassurance LED light in order to give visual information about the call status.Continues LED Light for easy visibility at night.'Call Initation and error notification procedures is the same as bedside call unit except audio alerts are always issued by the bedside call unit its call initiation button and back light works in parallel with the one on the bedside call unit.It shall have an easily cleanable surface that dose not promote bacterial growth.Patient handset shall be made from non inflammable PC-ABS-FR Materials. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos5900.05900.080.0FalseNoneNoneFalseNoneFalse472000.00
3646995132948NoneItem Least Quotation RateSupply, installation, testing and commissioning of CODE BLIE CALL UNIT;- The Code Blue Call Unit shall be mounted on headboards where there are patient headboards or on the walls where it can be implemented within the system. The Code Blue Call Unit has 2 Input/Output ports for RJ45 endings for cabling in a chain with Over Door Lights and other call units and eventually to one Zone Controller. On the Code Blue call unit front side there shall be; A “start code blue” button with a blue medicine symbol. Pressing the button initiates a Code Blue event, turning on the assigned Overdoor lights to Blue. An “end code blue” button with a green tick mark symbol. Pressing the Button shall cancel the Code blue alarm turning the assigned Overdoor lights. Reassurance backlight in order to give visual information about the call status. Continuous backlight for easy visibility of the unit at night. The Code Blue Call Unit shall be made from nonflammable PC-ABS-FR materials. If the unit is able to transmit the call to the zone controller, the LED on the unit shall flash with 1.0-second intervals. Call transmission information shall be audibly notified to the patient. If there is an error in call transmission, a continuous red light showing the error status shall only stop when the call termination button is pressed or room control connection is made. Subsequent presses of the button shall trigger an audio alert each time. Its connection shall be made with Cat 6 UTP cable and RJ45 of B standard. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos4071.04071.080.0FalseNoneNoneFalseNoneFalse325680.00
3646996132948NoneItem Least Quotation RateSupply, installation, testing and commissioning of PULL-CORD CALL UNIT(WC\Bathroom)-The Pull-cord call unit has 2 input\output ports for RJ45 Ending for cabling in a chain with overdoor lights and other call units and eventually to one zone controller. on its front side there shall be A pull-code call unit with customizable length with minimum 1.5 meters to serve as a call-code.A call termination button (indicated by a green tick Mark Symbol).Its Connection shall be made with CAT6 UTP cable and RJ45 of B standard.A priority WC Emergency call shall start when the cord is pulled.This Device will be used in the locations that are connected to the system by a zone controller. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos4189.04189.020.0FalseNoneNoneFalseNoneFalse83780.00
3646997132948NoneItem Least Quotation RateSupply, installation, testing and commissioning of 'Over Door Light shall use environmentally friendly LEDs.'It shall consist of Red, Green, Blue, white, Pink Colored Warning Light.'In Normal Condition, no light shall be lit, if the patient makes nurse call, Red Light shall be Lit with in 0.5 Seconds. After all nurse call, when the nurse presses the green presence button on the call unit, the light of the over door light will return green.'In code blue, the blue light shall be lit.'The outer casing of the over door light shall be made of nonflammble PC-ABS-FR Materials.'Over door light shall have 2 input\output ports for RJ45 ending for cabling in a chain with call units on one of the communication lines of the zone controller. Alternativley, it connects to the RCU in private & semi private rooms.'Its connection shall be made with cat 6 UTP Cable RJ45 of B Standard.'This device shall be powered by the Zone Controller or black colored communication ports of RCU unit to which it is connected. It shall not require additional energy supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos11463.6911463.6920.0FalseNoneNoneFalseNoneFalse229273.80
3646998132948NoneItem Least Quotation RateSupply, installation, testing and commissioning of 'IP BASED NURSE CALL SYSTEM Supply, Installation, testing and commissioning of the IP based Nurse Call System based on the following components including but not restricted to gold plated connecting leads, connectors, patch cables, jumpers, nuts, screws, bolts, mounting plates, cover plates, back boxes etc., 'Shall be in accordance with International guidelines and shall be in such a way that the most effective communication between Patient, Nursing Staff, Doctor & management staff can be provided in the least possible time. 'System Operation\Ward Nurse Station;-'The ward Nurse Station Shall be used in the location that are connected to the system by a zone controller. It is placed in each multi bed ward areas at the nurse station overlooking the patent beds.'The ward Nurse station Shall have a minimum 10 Inch touchscreen and include its own integrated handsfree voice communication with other Nurse control Panels.'The Nurse control panel may be used to monitor the status of every assigned call points, call and alarm status.the screen will show active calls and emergency code with top to bottom priority, highest priority active calls is on top and longest awaiting calls within same call type having more priority than same type.'The origin room and the bed information of all active nurse calls, code blue calls shall be shown with an audiovisual alert along with the call type.'onscreen call points shall have notification of relevant icons, colors, and tones according to their call status as well as time the call started and time passed since.'call shall be shown real time. Each activity will be send to IP System Controller for logging enabling later inspection and reporting.'Time stamp and error logs for situations when the energy supply of the panel is cut or there is no network connection shall be recorded on the IP System controller.'Emergency codeblue, Red, pink, and white shall be initiated from the touch screen. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos95138.6895138.686.0FalseNoneNoneFalseNoneFalse570832.080
3646999132948NoneItem Least Quotation RateSupply, installation, testing and commissioning of IP ZONE CONTROLLER This is the main node device used to network the Nurse call system devices to each other for areas are not private or semi-private rooms and do not have item 3.2(RCU). It is to be used for multi bed wards areas in a single open soace with a nurse desk overlooking the assigned patient beds.Each zone controller has 2 communication ports which support chains of up to 24 calls initiation devices each,and up to as many over door lights as the number of the call initiation devices, for a total maximum support of 48 call devices.The connection shall be made with cat 6 UTP Cable and RJ45 of B Standard. Toatl cable length from the Zone Controller to the last call device Cannot be longer than 500 meters for each communication line oneach communication port.Zone controller shall have 2 power injectors to be included with the device to be used for injecting 12V power to be used on each communication line. Each power injector has 2 RJ Ports to be connected at suitable location to prevent voltage drops on the lines.Each Power injector require 110-240 V Power.There shall not be any limits to the number of zone controllers that can be used in a nurse call system, they may be placed in the network switch, its connection shall be made with cat 6 UTP cable and RJ % of B Standard.The zone controller shall have 1 port for 110-240 V Power.'The zone controller must be configurable from the IP System Controller. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos85388.3485388.346.0FalseNoneNoneFalseNoneFalse512330.040
3647000132948NoneItem 8.1Supplying and drawing UTP-CAT 6E LAN cable ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr46.1846.184500.0FalseNoneNoneFalseNoneFalse207810.00
3647001132948NoneItem 1.2.2Supplying heavy gauge PVC Consealed conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr94.894.83500.0FalseNoneNoneFalseNoneFalse331800.00
3647002132948NoneItem 8.12.2Supplying & Fixing of Patch panel for LAN cabling .24 Port 10/100 patch panel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4983.134983.134.0FalseNoneNoneFalseNoneFalse19932.520
3647003132948NoneItem 1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet8600.178600.172.0FalseNoneNoneFalseNoneFalse17200.340
3647004132948NoneItem 2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet1352.741352.742.0FalseNoneNoneFalseNoneFalse2705.480
3647005132948NoneItem 6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo105.73105.736.0FalseNoneNoneFalseNoneFalse634.380
3647006132948NoneItem 13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo58.3358.336.0FalseNoneNoneFalseNoneFalse349.980
3647007132948NoneItem 2.16Supply of Spiral Earth Electrode ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo290.4290.42.0FalseNoneNoneFalseNoneFalse580.80
3647008132948NoneItem 2.16Erection of Spiral Earth Electrode ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo113.03113.032.0FalseNoneNoneFalseNoneFalse226.060
3647009132948NoneItem 68.17Supply and fixing of Caution/Danger Board ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo182.31182.311.0FalseNoneNoneFalseNoneFalse182.310
3647010132948NoneItem 4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach108.17108.172.0FalseNoneNoneFalseNoneFalse216.340
3647011132948NoneItem 5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach51.0451.042.0FalseNoneNoneFalseNoneFalse102.080
3647012132948NoneItem 24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet25839.425839.41.0FalseNoneNoneFalseNoneFalse25839.40
3647013132948NoneItem 24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo7378.697378.691.0FalseNoneNoneFalseNoneFalse7378.690
3647014132948NoneItem 25.01Supply of DOLO Cut Out ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet7140.477140.471.0FalseNoneNoneFalseNoneFalse7140.470
3647015132948NoneItem 13.01Erection of DOLO Cut Out ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet288.04288.041.0FalseNoneNoneFalseNoneFalse288.040
3647016132948NoneItem 1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet8600.178600.176.0FalseNoneNoneFalseNoneFalse51601.020
3647017132948NoneItem 2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet1352.741352.746.0FalseNoneNoneFalseNoneFalse8116.440
3647018132948NoneItem 2.02Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet591.89591.896.0FalseNoneNoneFalseNoneFalse3551.340
3647019132948NoneItem 2.02Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WL ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet312.35312.356.0FalseNoneNoneFalseNoneFalse1874.10
3647020132948NoneItem 6.06Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo249.15249.1518.0FalseNoneNoneFalseNoneFalse4484.70
3647021132948NoneItem 6.1Supply and fixing of 11 kV, 45 KN Polymeric Insulator ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo226.06226.0618.0FalseNoneNoneFalseNoneFalse4069.080
3647022132948NoneItem 13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo58.3358.3318.0FalseNoneNoneFalseNoneFalse1049.940
3647023132948NoneItem 6.08Supply and fixing of 15 Strain Insulator ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet71.771.74.0FalseNoneNoneFalseNoneFalse286.80
3647024132948NoneItem 7.02Supply of Rabbit ACSR Conductor ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm56192.856192.81.0FalseNoneNoneFalseNoneFalse56192.80
3647025132948NoneItem 6.02Erection of Rabbit ACSR Conductor ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm5300.355300.351.0FalseNoneNoneFalseNoneFalse5300.350
3647026132948NoneItem 10.01Supply and fixing of PG Clamps for Rabbit Conductor ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo170.15170.1515.0FalseNoneNoneFalseNoneFalse2552.250
3647027132948NoneItem 2.16Supply of Spiral Earth Electrode ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo290.48290.489.0FalseNoneNoneFalseNoneFalse2614.320
3647028132948NoneItem 2.16Erection of Spiral Earth Electrode ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo113.03113.039.0FalseNoneNoneFalseNoneFalse1017.270
3647029132948NoneItem 68.17Supply and fixing of Caution/Danger Board ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo182.31182.315.0FalseNoneNoneFalseNoneFalse911.550
3647030132948NoneItem 4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach108.17108.176.0FalseNoneNoneFalseNoneFalse649.020
3647031132948NoneItem 5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach51.0451.046.0FalseNoneNoneFalseNoneFalse306.240
3647032132948NoneItem 41.01Load Break Switch with Panel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo89014.6889014.681.0FalseNoneNoneFalseNoneFalse89014.680
3647033132948NoneItem 58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo295915.86295915.861.0FalseNoneNoneFalseNoneFalse295915.860
3647034132948NoneItem 53.01CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port UNIDIRACTIONAL (Used for HT Installation, LT Metering Cubicle 50 150 KW ) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo23840.0723840.071.0FalseNoneNoneFalseNoneFalse23840.070
3647035132948NoneItem 13.1Supply, erection, testing and commissioning of 500 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1188649.041188649.041.0FalseNoneNoneFalseNoneFalse1188649.040
3647036132948NoneItem 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo4266.04266.010.0FalseNoneNoneFalseNoneFalse42660.00
3647037132948NoneItem 12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr155.57155.57100.0FalseNoneNoneFalseNoneFalse15557.00
3647038132948NoneItem 12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr1996.91996.9100.0FalseNoneNoneFalseNoneFalse199690.00
3647039132948NoneItem 12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach9019.489019.4810.0FalseNoneNoneFalseNoneFalse90194.80
3647040132948NoneItem 45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet4943.034943.034.0FalseNoneNoneFalseNoneFalse19772.120
3647041132948NoneItem 45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet3813.923813.922.0FalseNoneNoneFalseNoneFalse7627.840
3647042132948NoneItem 36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm1081300.051081300.050.1FalseNoneNoneFalseNoneFalse108130.0050
3647043132948NoneItem 38Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1199.591199.59150.0FalseNoneNoneFalseNoneFalse179938.50
3647044132948NoneItem 5.40.5Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 1000Amps double run of 4x60x10mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr12858.9312858.9310.0FalseNoneNoneFalseNoneFalse128589.30
3647045132948NoneItem 5.41.3Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr674.54674.5412.0FalseNoneNoneFalseNoneFalse8094.480
3647046132948NoneItem 5.41.5Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x150x75x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr1125.461125.4612.0FalseNoneNoneFalseNoneFalse13505.520
3647047132948NoneItem 5.15.20Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 800Amps 50kA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach60648.4660648.461.0FalseNoneNoneFalseNoneFalse60648.460
3647048132948NoneItem Least Quotation RateSupplying, installing, testing and commissioning of 180KVA/144kw Diesel Generator set (CPCB 4 norms) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet2224300.02224300.01.0FalseNoneNoneFalseNoneFalse2224300.00
3647049132948NoneItem 10.2.5Supply, Erection, testing and commissioning of AMF panel suitable for .....KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....amps 4 pole contactor for alternator with thermal O/L relay,..... Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 180 KVA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach171727.51171727.511.0FalseNoneNoneFalseNoneFalse171727.510
3647050132948NoneItem Least Quotation RateSupply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem9440.09440.015.0FalseNoneNoneFalseNoneFalse141600.00
3647051132948NoneItem Least Quotation RateSupply and installing of DG set stack using angular structure, channel, necessary nut and bolt and all required accessories for erecting exhaust pipe from 2 nos DG set and space provision for provinding exhaust pipe for 2 more DG set in future. The design of the stack with foundation shall be got approved before fabrication. The foundation for the stack shall be measured separately. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg236.0236.0300.0FalseNoneNoneFalseNoneFalse70800.00
3647052132948NoneItem Least Quotation RateSupply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr236.0236.0100.0FalseNoneNoneFalseNoneFalse23600.00
3647053132948NoneItem 5.40.2Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr4174.94174.916.0FalseNoneNoneFalseNoneFalse66798.40
3647054132948NoneItem 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr370.7370.756.0FalseNoneNoneFalseNoneFalse20759.20
17223352660000NoneNoneBuildingsQuarters inetrnal and external Electric works2959299.66
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3647055132949NoneItem 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint326.94326.9446.0FalseNoneNoneFalseNoneFalse15039.240
3647056132949NoneItem 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint460.63460.6359.0FalseNoneNoneFalseNoneFalse27177.170
3647057132949NoneItem 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for eachoutlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint674.54674.5455.0FalseNoneNoneFalseNoneFalse37099.70
3647058132949NoneItem 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach167.72167.7239.0FalseNoneNoneFalseNoneFalse6541.080
3647059132949NoneItem 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach193.24193.2439.0FalseNoneNoneFalseNoneFalse7536.360
3647060132949NoneItem 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach215.12215.1231.0FalseNoneNoneFalseNoneFalse6668.720
3647061132949NoneItem 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach267.38267.3814.0FalseNoneNoneFalseNoneFalse3743.320
3647062132949NoneItem 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach317.21317.2120.0FalseNoneNoneFalseNoneFalse6344.20
3647063132949NoneItem 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach387.71387.7122.0FalseNoneNoneFalseNoneFalse8529.620
3647064132949NoneItem 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach166.5166.539.0FalseNoneNoneFalseNoneFalse6493.50
3647065132949NoneItem 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.67195.6739.0FalseNoneNoneFalseNoneFalse7631.130
3647066132949NoneItem 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach212.69212.6931.0FalseNoneNoneFalseNoneFalse6593.390
3647067132949NoneItem 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach284.4284.414.0FalseNoneNoneFalseNoneFalse3981.60
3647068132949NoneItem 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach345.17345.1720.0FalseNoneNoneFalseNoneFalse6903.40
3647069132949NoneItem 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach418.09418.0922.0FalseNoneNoneFalseNoneFalse9197.980
3647070132949NoneItem 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach123.97123.97260.0FalseNoneNoneFalseNoneFalse32232.20
3647071132949NoneItem 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach201.75201.7530.0FalseNoneNoneFalseNoneFalse6052.50
3647072132949NoneItem 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach207.83207.8386.0FalseNoneNoneFalseNoneFalse17873.380
3647073132949NoneItem 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach433.89433.8924.0FalseNoneNoneFalseNoneFalse10413.360
3647074132949NoneItem 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach396.22396.2250.0FalseNoneNoneFalseNoneFalse19811.00
3647075132949NoneItem 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach286.83286.8350.0FalseNoneNoneFalseNoneFalse14341.50
3647076132949NoneItem 1.13Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo142.2142.220.0FalseNoneNoneFalseNoneFalse2844.00
3647077132949NoneItem 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293TV/Telephone socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach189.6189.616.0FalseNoneNoneFalseNoneFalse3033.60
3647078132949NoneItem 12.2.1Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong Bell ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach298.98298.986.0FalseNoneNoneFalseNoneFalse1793.880
3647079132949NoneItem 1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr80.2180.211350.0FalseNoneNoneFalseNoneFalse108283.50
3647080132949NoneItem 1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr94.894.82100.0FalseNoneNoneFalseNoneFalse199080.00
3647081132949NoneItem 1.2.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr125.18125.18125.0FalseNoneNoneFalseNoneFalse15647.50
3647082132949NoneItem 1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr82.6482.64420.0FalseNoneNoneFalseNoneFalse34708.80
3647083132949NoneItem 1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr96.0196.01705.0FalseNoneNoneFalseNoneFalse67687.050
3647084132949NoneItem 1.3.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr120.32120.3250.0FalseNoneNoneFalseNoneFalse6016.00
3647085132949NoneItem 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr31.631.6555.0FalseNoneNoneFalseNoneFalse17538.00
3647086132949NoneItem 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr51.0451.042215.0FalseNoneNoneFalseNoneFalse113053.60
3647087132949NoneItem 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr76.5776.571650.0FalseNoneNoneFalseNoneFalse126340.50
3647088132949NoneItem 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr111.81111.81585.0FalseNoneNoneFalseNoneFalse65408.850
3647089132949NoneItem 5.19.8Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure II - Double Door 8 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2253.352253.353.0FalseNoneNoneFalseNoneFalse6760.050
3647090132949NoneItem 5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure II - Double Door 12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2830.662830.666.0FalseNoneNoneFalseNoneFalse16983.960
3647091132949NoneItem 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach504.39504.3973.0FalseNoneNoneFalseNoneFalse36820.470
3647092132949NoneItem 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5198.265198.269.0FalseNoneNoneFalseNoneFalse46784.340
3647093132949NoneItem 32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm107463.23107463.230.5FalseNoneNoneFalseNoneFalse53731.6150
3647094132949NoneItem 31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm25384.8425384.840.5FalseNoneNoneFalseNoneFalse12692.420
3647095132949NoneItem 6.11.1Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach82.6482.6412.0FalseNoneNoneFalseNoneFalse991.680
3647096132949NoneItem 6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach15.1115.1148.0FalseNoneNoneFalseNoneFalse725.280
3647097132949NoneItem 8.2.2Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr25.5225.52400.0FalseNoneNoneFalseNoneFalse10208.00
3647098132949NoneItem 8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr53.4753.47400.0FalseNoneNoneFalseNoneFalse21388.00
3647099132949NoneItem 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo4266.054266.056.0FalseNoneNoneFalseNoneFalse25596.30
3647100132949NoneItem 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr99.6699.6622.0FalseNoneNoneFalseNoneFalse2192.520
3647101132949NoneItem 11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach838.62838.6234.0FalseNoneNoneFalseNoneFalse28513.080
3647102132949NoneItem 11.11.5Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach326.94326.9416.0FalseNoneNoneFalseNoneFalse5231.040
3647103132949NoneItem 11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach181.09181.0926.0FalseNoneNoneFalseNoneFalse4708.340
3647104132949NoneItem 11.11.5Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach326.94326.9416.0FalseNoneNoneFalseNoneFalse5231.040
3647105132949NoneItem 11.11.7Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach517.76517.7610.0FalseNoneNoneFalseNoneFalse5177.60
3647106132949NoneItem 12.27Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach63.263.212.0FalseNoneNoneFalseNoneFalse758.40
3647107132949NoneItem 12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach76.5776.5764.0FalseNoneNoneFalseNoneFalse4900.480
3647108132949NoneItem 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1813.371813.3714.0FalseNoneNoneFalseNoneFalse25387.180
3647109132949NoneItem 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3253.623253.6220.0FalseNoneNoneFalseNoneFalse65072.40
3647110132949NoneItem 11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo2947.342947.346.0FalseNoneNoneFalseNoneFalse17684.040
3647111132949NoneItem 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach148.27148.2770.0FalseNoneNoneFalseNoneFalse10378.90
3647112132949NoneItem 13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach382.85382.8520.0FalseNoneNoneFalseNoneFalse7657.00
3647113132949NoneItem 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach859.28859.2814.0FalseNoneNoneFalseNoneFalse12029.920
3647114132949NoneItem 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1775.691775.696.0FalseNoneNoneFalseNoneFalse10654.140
3647115132949NoneItem 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach196.89196.896.0FalseNoneNoneFalseNoneFalse1181.340
3647116132949NoneItem 5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.520.52288000.0FalseNoneNoneFalseNoneFalse149760.00
3647117132949NoneItem 5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x10mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr2995.962995.9615.0FalseNoneNoneFalseNoneFalse44939.40
3647118132949NoneItem 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr370.69370.6915.0FalseNoneNoneFalseNoneFalse5560.350
3647119132949NoneItem 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr918.84918.8415.0FalseNoneNoneFalseNoneFalse13782.60
3647120132949NoneItem 5.14.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 100Amps 25kA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach10315.0910315.093.0FalseNoneNoneFalseNoneFalse30945.270
3647121132949NoneItem 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3699.673699.675.0FalseNoneNoneFalseNoneFalse18498.350
3647122132949NoneItem 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach898.18898.1810.0FalseNoneNoneFalseNoneFalse8981.80
3647123132949NoneItem 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach11321.4511321.453.0FalseNoneNoneFalseNoneFalse33964.350
3647124132949NoneItem 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach625.93625.935.0FalseNoneNoneFalseNoneFalse3129.650
3647125132949NoneItem 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach683.05683.059.0FalseNoneNoneFalseNoneFalse6147.450
3647126132949NoneItem 5.7.2Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers32Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach292.91292.9110.0FalseNoneNoneFalseNoneFalse2929.10
3647127132949NoneItem 5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers63Amps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach487.37487.375.0FalseNoneNoneFalseNoneFalse2436.850
3647128132949NoneItem 5.3Supplying, fixing and wiring electronic 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1677.251677.259.0FalseNoneNoneFalseNoneFalse15095.250
3647129132949NoneItem 7.1.3Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.25Litres ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach12448.1212448.126.0FalseNoneNoneFalseNoneFalse74688.720
3647130132949NoneItem 1.01Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet8600.178600.172.0FalseNoneNoneFalseNoneFalse17200.340
3647131132949NoneItem 2.02Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet1352.741352.742.0FalseNoneNoneFalseNoneFalse2705.480
3647132132949NoneItem 6.05Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo105.73105.736.0FalseNoneNoneFalseNoneFalse634.380
3647133132949NoneItem 13.12Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo58.3358.336.0FalseNoneNoneFalseNoneFalse349.980
3647134132949NoneItem 2.16Supply of Spiral Earth Electrode ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo290.48290.482.0FalseNoneNoneFalseNoneFalse580.960
3647135132949NoneItem 2.16Erection of Spiral Earth Electrode ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo113.03113.032.0FalseNoneNoneFalseNoneFalse226.060
3647136132949NoneItem 68.17Supply and fixing of Caution/Danger Board ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo182.31182.311.0FalseNoneNoneFalseNoneFalse182.310
3647137132949NoneItem 4.02Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach108.17108.172.0FalseNoneNoneFalseNoneFalse216.340
3647138132949NoneItem 5.09Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach51.0451.042.0FalseNoneNoneFalseNoneFalse102.080
3647139132949NoneItem 24.05Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet25839.425839.41.0FalseNoneNoneFalseNoneFalse25839.40
3647140132949NoneItem 24.07Supply and fixing of H-Frame for mounting GOS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo7378.697378.691.0FalseNoneNoneFalseNoneFalse7378.690
3647141132949NoneItem 25.01Supply of DOLO Cut Out ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet7140.477140.471.0FalseNoneNoneFalseNoneFalse7140.470
3647142132949NoneItem 13.01Erection of DOLO Cut Out ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet288.04288.041.0FalseNoneNoneFalseNoneFalse288.040
3647143132949NoneItem 13.07Supply, erection, testing and commissioning of 63 KVA 5Star rated Aluminium wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, , oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach206940.08206940.081.0FalseNoneNoneFalseNoneFalse206940.080
3647144132949NoneItem 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo4266.054266.058.0FalseNoneNoneFalseNoneFalse34128.40
3647145132949NoneItem 12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem155.57155.57100.0FalseNoneNoneFalseNoneFalse15557.00
3647146132949NoneItem 12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr1996.91996.9100.0FalseNoneNoneFalseNoneFalse199690.00
3647147132949NoneItem 12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach9019.489019.4810.0FalseNoneNoneFalseNoneFalse90194.80
3647148132949NoneItem 45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet4943.034943.034.0FalseNoneNoneFalseNoneFalse19772.120
3647149132949NoneItem 45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet3813.923813.922.0FalseNoneNoneFalseNoneFalse7627.840
3647150132949NoneItem 36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm1081300.051081300.050.1FalseNoneNoneFalseNoneFalse108130.0050
3647151132949NoneItem 38Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1199.591199.59150.0FalseNoneNoneFalseNoneFalse179938.50
3647152132949NoneItem 5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.520.52176000.0FalseNoneNoneFalseNoneFalse91520.00
3647153132949NoneItem 5.40.2Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr4174.894174.896.0FalseNoneNoneFalseNoneFalse25049.340
3647154132949NoneItem 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr370.69370.6912.0FalseNoneNoneFalseNoneFalse4448.280
3647155132949NoneItem 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr918.84918.8412.0FalseNoneNoneFalseNoneFalse11026.080
3647156132949NoneItem 5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach28616.5928616.591.0FalseNoneNoneFalseNoneFalse28616.590
3647157132949NoneItem 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach625.93625.933.0FalseNoneNoneFalseNoneFalse1877.790
17223352660000NoneNoneBuildingsMortury electrical works136923.37
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3647158132950NoneItem 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint326.94326.944.0FalseNoneNoneFalseNoneFalse1307.760
3647159132950NoneItem 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint460.63460.634.0FalseNoneNoneFalseNoneFalse1842.520
3647160132950NoneItem 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargePoint674.54674.546.0FalseNoneNoneFalseNoneFalse4047.240
3647161132950NoneItem 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach167.72167.721.0FalseNoneNoneFalseNoneFalse167.720
3647162132950NoneItem 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach193.24193.243.0FalseNoneNoneFalseNoneFalse579.720
3647163132950NoneItem 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach215.12215.128.0FalseNoneNoneFalseNoneFalse1720.960
3647164132950NoneItem 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach317.21317.218.0FalseNoneNoneFalseNoneFalse2537.680
3647165132950NoneItem 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach166.5166.51.0FalseNoneNoneFalseNoneFalse166.50
3647166132950NoneItem 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach195.67195.673.0FalseNoneNoneFalseNoneFalse587.010
3647167132950NoneItem 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach212.69212.698.0FalseNoneNoneFalseNoneFalse1701.520
3647168132950NoneItem 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach345.17345.178.0FalseNoneNoneFalseNoneFalse2761.360
3647169132950NoneItem 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach123.97123.9720.0FalseNoneNoneFalseNoneFalse2479.40
3647170132950NoneItem 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach207.83207.836.0FalseNoneNoneFalseNoneFalse1246.980
3647171132950NoneItem 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach433.89433.891.0FalseNoneNoneFalseNoneFalse433.890
3647172132950NoneItem 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach396.22396.2210.0FalseNoneNoneFalseNoneFalse3962.20
3647173132950NoneItem 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach286.83286.8310.0FalseNoneNoneFalseNoneFalse2868.30
3647174132950NoneItem 1.13Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo142.2142.21.0FalseNoneNoneFalseNoneFalse142.20
3647175132950NoneItem 1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr80.2180.21100.0FalseNoneNoneFalseNoneFalse8021.00
3647176132950NoneItem 1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr94.894.8120.0FalseNoneNoneFalseNoneFalse11376.00
3647177132950NoneItem 1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr82.6482.6450.0FalseNoneNoneFalseNoneFalse4132.00
3647178132950NoneItem 1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr96.0196.0160.0FalseNoneNoneFalseNoneFalse5760.60
3647179132950NoneItem 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr31.631.640.0FalseNoneNoneFalseNoneFalse1264.00
3647180132950NoneItem 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr51.0451.04135.0FalseNoneNoneFalseNoneFalse6890.40
3647181132950NoneItem 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr76.5776.57150.0FalseNoneNoneFalseNoneFalse11485.50
3647182132950NoneItem 5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2830.662830.661.0FalseNoneNoneFalseNoneFalse2830.660
3647183132950NoneItem 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach504.39504.3910.0FalseNoneNoneFalseNoneFalse5043.90
3647184132950NoneItem 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5198.265198.261.0FalseNoneNoneFalseNoneFalse5198.260
3647185132950NoneItem 32.041.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 2 core 16 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm107463.23107463.230.05FalseNoneNoneFalseNoneFalse5373.16150
3647186132950NoneItem 31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm25384.8425384.840.05FalseNoneNoneFalseNoneFalse1269.2420
3647187132950NoneItem 6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach15.1115.118.0FalseNoneNoneFalseNoneFalse120.880
3647188132950NoneItem 11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach838.62838.628.0FalseNoneNoneFalseNoneFalse6708.960
3647189132950NoneItem 11.6.3Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' - 34 -36watt ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5533.715533.714.0FalseNoneNoneFalseNoneFalse22134.840
3647190132950NoneItem 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1813.371813.372.0FalseNoneNoneFalseNoneFalse3626.740
3647191132950NoneItem 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3253.623253.621.0FalseNoneNoneFalseNoneFalse3253.620
3647192132950NoneItem 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach148.27148.2712.0FalseNoneNoneFalseNoneFalse1779.240
3647193132950NoneItem 13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach382.85382.851.0FalseNoneNoneFalseNoneFalse382.850
3647194132950NoneItem 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach859.28859.282.0FalseNoneNoneFalseNoneFalse1718.560
17223352660000NoneNoneBuildingsTLH SHIRAHATTI FIRE FIGHTING13538783.55
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3647195132951NoneItem 15.81.1Supply, erection, testing & commissioning of electrical motor driven end suction back pull out centrifugal pump capable of delivering,adequate LPM at required head. when running at 2900 rpm directly coupled to TEFC electrical motor of adequate HP to operate on 400/440 V 3 phase, 50 cycles AC supply with required foundation for pump, a terminal box suitable for reception, common bed plate with necessary anti vibration pads, necessary foundation bolts and accessories,neoprine gaskets (16 kg/sq.cm) Control panel is excluded.Required GA drawingfor the pump/ foundation shall be (2280 lpm at 70m head ) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo346389.0346389.01.0FalseNoneNoneFalseNoneFalse346389.00
3647196132951NoneItem 15.82.1Supply, installation, testing & commissioning of diesel engine driven pump, horizontal mounted, Horizontal spiltcase centrifugal single stage pump, capable of delivering required flow at required head when running at 1800 RPM with adequate BHP automatic diesel engine driven pumpset having the residential silencer system and other accessories like fuel tank, necessary radiator cooling system, flanges, neoprene gaskets (16.0 kg/sqcm), 200 litres fuel storage tank with piping, valves as per detailed specification and two separate starting mechanisms (automatic starting by battery power, electric starting motor as well as manual starting by electric start motor) common bed plate with anti vibration pads, necessary foundation, foundation bolts etc., (2280 lpm at 70m head ) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo680624.0680624.01.0FalseNoneNoneFalseNoneFalse680624.00
3647197132951NoneItem 15.85.4Supplying, Installing testing & commissioning electrically driven jockey pump of capacity 180.0 Lmpm at 100.0m head with all the necessary accessories viz. Pressure guages etc. operating on 3Ph 50Hz, 400/440V AC supply including foundation bolt etc. complete. Control panel shall be as per item No.87, including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo127617.0127617.01.0FalseNoneNoneFalseNoneFalse127617.00
3647198132951NoneItem 15.14Supply,erection,testing and commissioning of FireFighting panel cubicle type made out of 14/16Swg MSCRCA sheet which is erusted,degreased,phosphated and passivated with angle iron skeleton or sheet folded construction. For jockey ,electrical & DG pump ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeUnit352466.0352466.01.0FalseNoneNoneFalseNoneFalse352466.00
3647199132951NoneItem 15.127.2Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 150mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos15192.515192.512.0FalseNoneNoneFalseNoneFalse182310.00
3647200132951NoneItem 15.127.3Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 100mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos10938.5910938.598.0FalseNoneNoneFalseNoneFalse87508.720
3647201132951NoneItem 15.127.4Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 80mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos8507.88507.82.0FalseNoneNoneFalseNoneFalse17015.60
3647202132951NoneItem 15.128.2Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos13977.0913977.096.0FalseNoneNoneFalseNoneFalse83862.540
3647203132951NoneItem 15.128.3Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos8653.648653.643.0FalseNoneNoneFalseNoneFalse25960.920
3647204132951NoneItem 15.128.4Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos6684.76684.72.0FalseNoneNoneFalseNoneFalse13369.40
3647205132951NoneItem 15.129.1Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.200mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo29777.329777.33.0FalseNoneNoneFalseNoneFalse89331.90
3647206132951NoneItem 15.129.3Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo15058.815058.83.0FalseNoneNoneFalseNoneFalse45176.40
3647207132951NoneItem 15.136Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo36462.036462.01.0FalseNoneNoneFalseNoneFalse36462.00
3647208132951NoneItem 15.132Pressure guage of 150 mm dia including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo3524.663524.663.0FalseNoneNoneFalseNoneFalse10573.980
3647209132951NoneItem 15.131Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2370.022370.026.0FalseNoneNoneFalseNoneFalse14220.120
3647210132951NoneItem 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg178.66178.662000.0FalseNoneNoneFalseNoneFalse357320.00
3647211132951NoneItem 32.14FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed. 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm).Main Panel Electrical Pump ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm453605.51453605.510.1FalseNoneNoneFalseNoneFalse45360.5510
3647212132951NoneItem 32.05FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed. 4.0 Core 16.00 Sq.mm.Main Panel to Jockey ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKm172394.76172394.760.2FalseNoneNoneFalseNoneFalse34478.9520
3647213132951NoneItem Least Quotation Rate12 Core x 2.5Sqmm For Main Panel to DG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr684.4684.465.0FalseNoneNoneFalseNoneFalse44486.00
3647214132951NoneItem Least Quotation Rate3 Core x 1.5Sqmm for Pressure Switch ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr87.5187.51120.0FalseNoneNoneFalseNoneFalse10501.20
3647215132951NoneItem 9.4.6Supplying, installation, testing & commissioning of 12V ..AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type.150 AH capacity ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos32823.0932823.091.0FalseNoneNoneFalseNoneFalse32823.090
3647216132951NoneItem 12.59Supplying and installing following size of perforated painted with powder cating m.s. cable trays with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspendrrs etc as required. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr944.36944.36120.0FalseNoneNoneFalseNoneFalse113323.20
3647217132951NoneItem 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr99.6699.66220.0FalseNoneNoneFalseNoneFalse21925.20
3647218132951NoneItem 15.86Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1823.11823.18.0FalseNoneNoneFalseNoneFalse14584.80
3647219132951NoneItem 15.125SITC of Gun metal BALL VALVE SIZE OF 25mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1458.481458.488.0FalseNoneNoneFalseNoneFalse11667.840
3647220132951NoneItem 15.125SITC of Gun metal BALL VALVE SIZE OF 19/20 mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1154.621154.628.0FalseNoneNoneFalseNoneFalse9236.960
3647221132951NoneItem 15.97.3Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 150 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem4740.054740.05400.0FalseNoneNoneFalseNoneFalse1896020.00
3647222132951NoneItem 15.97.4Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.100 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem3463.893463.89300.0FalseNoneNoneFalseNoneFalse1039167.00
3647223132951NoneItem 15.97.5Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.80 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2795.422795.42200.0FalseNoneNoneFalseNoneFalse559084.00
3647224132951NoneItem 15.97.6Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.65 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem2066.182066.18200.0FalseNoneNoneFalseNoneFalse413236.00
3647225132951NoneItem 15.97.7Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.50 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem1580.021580.02250.0FalseNoneNoneFalseNoneFalse395005.00
3647226132951NoneItem 15.97.8Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.40 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem1276.161276.16300.0FalseNoneNoneFalseNoneFalse382848.00
3647227132951NoneItem 15.97.9Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.32 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem972.31972.31300.0FalseNoneNoneFalseNoneFalse291693.00
3647228132951NoneItem 15.97.10Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.25 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem850.78850.78350.0FalseNoneNoneFalseNoneFalse297773.00
3647229132951NoneItem 15.98.2Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 150 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem486.15486.15300.0FalseNoneNoneFalseNoneFalse145845.00
3647230132951NoneItem 15.98.3Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 100 mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem303.84303.84100.0FalseNoneNoneFalseNoneFalse30384.00
3647231132951NoneItem 15.127.6Supplying, installing , testing and commissioning approved make CI butterfly valves of 50mm diameter confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos5469.295469.296.0FalseNoneNoneFalseNoneFalse32815.740
3647232132951NoneItem 18.23.2Providing & fixing Flow Switch in following sizes M.S. pipe including connnection etc as required.150mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach10964.1210964.126.0FalseNoneNoneFalseNoneFalse65784.720
3647233132951NoneItem 15.96.2Providing, fixing, testing & commissioning ofinstallation control valve of cast iron body,brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm andhydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach85078.085078.01.0FalseNoneNoneFalseNoneFalse85078.00
3647234132951NoneItem 15.123Supplying Installing, testing and commissioning of 150mm dia 4 way Fire brigade inlet connection with Non retrn valve of 4 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo46185.246185.21.0FalseNoneNoneFalseNoneFalse46185.20
3647235132951NoneItem 15.124Supplying Installing, testing and commissioning of 100mm dia 2 way Fire brigade inlet connection of 2 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo40108.240108.21.0FalseNoneNoneFalseNoneFalse40108.20
3647236132951NoneItem 15.86FIRE HYDRANT SYSTEM Supplying Installing, testing and commissioning of 63mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve,spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo12761.6912761.696.0FalseNoneNoneFalseNoneFalse76570.140
3647237132951NoneItem 15.85Supplying Installing, testing and commissioning of63mm mm dia double headed Gun mental Hydrant Valve with flanged inlet 2Nos, stop valve, spindle and cast iron hand wheel. It has a 2 Nos female instantaneous outlet with blank cap and is hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm2 of pressure confirms to IS : 2190 with blank cap and wheel as per IS 5290 etc. including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo22484.8922484.8910.0FalseNoneNoneFalseNoneFalse224848.90
3647238132951NoneItem 15.88Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos .RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6077.06077.032.0FalseNoneNoneFalseNoneFalse194464.00
3647239132951NoneItem 15.87Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour,usage charges of machinery complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5469.295469.2916.0FalseNoneNoneFalseNoneFalse87508.640
3647240132951NoneItem 15.89Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size 20"x24"x10" complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7900.097900.0910.0FalseNoneNoneFalseNoneFalse79000.90
3647241132951NoneItem 15.119Supplying and fixing of Fire duct Shutter fabricated out of M.S.sheet and frame, door shall befixed with 4 mm thick Glass, suitable Rubber beading and Locking arrangement. Rate shall be includes all fasteners etc, and complete shutter shall be powder coated of approved colour both inside and outside ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach15192.515192.56.0FalseNoneNoneFalseNoneFalse91155.00
3647242132951NoneItem 15.91Supplying Installing, testing and commissioning of Hose reel cabin ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6198.546198.546.0FalseNoneNoneFalseNoneFalse37191.240
3647243132951NoneItem 15.92Supplying Installing, of M.S. Pressed reel of 600mm dia swinging type motion which allows a 180 swing and conforms to IS:884/85 or Aluminium fitting Single Piece Compact Type. including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6320.086320.086.0FalseNoneNoneFalseNoneFalse37920.480
3647244132951NoneItem 13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1823.11823.120.0FalseNoneNoneFalseNoneFalse36462.00
3647245132951NoneItem 15.93Supplying Installing, testing and commissioning of approved make 15mm dia sprinkler bulb pendent/wall mounted type designed to operate 68 degrees centegrad Make Tyco/HD FIRE complete (Colour code of bulb liquid inside Glass bulb type Pendents As per IS 9972: 57COrange, 68C - Red, 79C - Yellow, 93C - Green, 141C - Blue, 182C Mauve, 227/260C - Black) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach455.77455.77600.0FalseNoneNoneFalseNoneFalse273462.00
3647246132951NoneItem 15.122Stainless steel braided flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and 1500 mm long 25 mm dia with union / reducer collar, clamps etc. as required. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3038.53038.5100.0FalseNoneNoneFalseNoneFalse303850.00
3647247132951NoneItem 15.12Supplying Installing, testing and commissioning of Ceiling Mounted powder coated Surface Finishing Mild Steel Rosette Plate including cost of materials, labour, usage charges of machinery complete as per specifications ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach133.69133.69100.0FalseNoneNoneFalseNoneFalse13369.00
3647248132951NoneItem Least Quotation RateSupply, erection, testing and commissioning of 1" GI/MS collar. ---- etc.,complete with all leads And lifts as per specifications and as directed by the Engineer-in-charge . ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos129.79129.79600.0FalseNoneNoneFalseNoneFalse77874.00
3647249132951NoneItem 15.33CO2 2Kg Squeeze grip Providing 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6684.76684.76.0FalseNoneNoneFalseNoneFalse40108.20
3647250132951NoneItem 15.34Supply, installation in position, testing and commissioning of 4.5Kg C0 Gas Type Fire Extinugisher, Trolley Mounted, 2 Easy Weight Management used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuctin : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved 1Year Warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7900.097900.096.0FalseNoneNoneFalseNoneFalse47400.540
3647251132951NoneItem 15.4Providing Aqueous Film-Forming Foam - 9 Ltr Providing 9 Ltr Fire Extinugisher Aqueous Film-Forming Foam Type, Stored Pressure Type, Pressure Gauge, Gross Weight 15.1Okg. empty weight 6.10kg Can Height 615 MM, Diameter 175 MM, Discharge Time less than 60 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 6 Meters, applicable on Class A,8,CARating 13A, 8 Rating 558, Can Construction;Deep drawn & CO, Mig welded, Valve Construction: Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy PoIyster Powder coating, Sheet metal thickness: 2.0MM, lSI and EN Approved, Helium Leak Detection Tested, 1 Years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach9844.749844.742.0FalseNoneNoneFalseNoneFalse19689.480
3647252132951NoneItem 15.4Providing ABC Powder based MAP 50, 6Kg:-Providing 6kg Fire Extinguisher Mono Ammonium Phos phate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire, A Rating 3A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete. IS 15683 Approved, ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3463.893463.8910.0FalseNoneNoneFalseNoneFalse34638.90
3647253132951NoneItem 15.49Supply and installation of 6 Ltr Watermist technology base, Stored pressure type, Rating -8A. 34B & 40F, Mild steel body t, Tamper- proof safety seal, Effective on Class-A, Class-B, Class-F and Electrically Started Fires, Built-in pressure gauge, lnstalert, Uses distilled water, Gross Weight 12.15 Kg, empty Weight 6.15kg, can Height 615mm Diameter 175M M, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Can Construction: Deep drawn & C02 Mig welded, Valve Construction: Forgin & Machining, ERDA approved, Sheet metal thickness : 2.00MM, Discharge Time : Min. 64 Sec., 5 Year Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall,, labour, usage charges of machinery complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach9358.589358.586.0FalseNoneNoneFalseNoneFalse56151.480
3647254132951NoneItem 15.112Supplying of two bucket stand alongwith buckets. complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1336.931336.934.0FalseNoneNoneFalseNoneFalse5347.720
3647255132951NoneItem 15.72Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(Signage with the following text "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" Size:-25cm x 30 cm) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM2.432.434500.0FalseNoneNoneFalseNoneFalse10935.00
3647256132951NoneItem 15.72Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(Floor identification signage ( ie, GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm.) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM2.432.435400.0FalseNoneNoneFalseNoneFalse13122.00
3647257132951NoneItem 15.72Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(signage with text FIRE EXIT,Size shall be 15cm x 60cm.) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM2.432.435400.0FalseNoneNoneFalseNoneFalse13122.00
3647258132951NoneItem 15.106A) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS. B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POITS. C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER. D) BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC, WALK, DO NOT RUN E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, LIE DOWN FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3038.53038.56.0FalseNoneNoneFalseNoneFalse18231.00
3647259132951NoneItem 15.106ACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM. A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: (Current phone numbers to be provided in this location by the contractor) C) REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE. D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE. E) IN CASE OF THE CASUALTIES (Current phone numbers to be pro, CALL AMBULANCE BY DIALLING NUMBER: (Current phone numbers to be provided in this location by the contractor) F) FIRE FIGHTING AGENCY: PHONE :vided in this location by the contractor) FAX : (Current fax numbers to be provided in this location by the contractor) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3038.53038.56.0FalseNoneNoneFalseNoneFalse18231.00
3647260132951NoneItem 15.72Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(route plan Fire Escape Route Plan A2 Size) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2.432.4312000.0FalseNoneNoneFalseNoneFalse29160.00
3647261132951NoneItem Least Quotation RateSupply installation testing commissioning of P.A System Rack made out of 18 gauge M.S. Sheet with glass door with locking arrangement and powder coating grey paint two coats at inner and outer of box, is to accomodated 1 No. 250 watt amplifire, 1 No. 40 zone console and 1 no Mike and in built electronic connections circuits.Size or Rack: 0.50 m hight x 0.40 m width x 0.40 m depth ---- including all lead and lift charges loading and unloading charges labour charges, curing, cost& conveyance of all materials, transportation charges, all incidental charges, hire charges of all machinery and equipment required for successful completion of work etc., complete. The work shall be executed as per standard technical specification and directions of Engineer in charge of the work ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos58410.058410.01.0FalseNoneNoneFalseNoneFalse58410.00
3647262132951NoneItem 15.108.3Supplying Installing, testing and commissioning of P.A.System console panel with push button with speaker and indictoron Accomdated in M.S.Cabinet with painting -do- 40 Zone cansole. Complete ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos98447.498447.41.0FalseNoneNoneFalseNoneFalse98447.40
3647263132951NoneItem 15.109P.A.System amplifier 250W RMS out put with complete wiring and controls accessable form front ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos42842.8542842.851.0FalseNoneNoneFalseNoneFalse42842.850
3647264132951NoneItem 15.109Supplying Installing, testing and commissioning of MIKE ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6684.76684.71.0FalseNoneNoneFalseNoneFalse6684.70
3647265132951NoneItem 15.107Supplying Installing, testing and commissioning of Public address system (Two way comminication type) as per requirement of Fire Force authority and which Generally comprise of Supplying Installing, testing and commissioning of Approved make 5W.wall mounted speaker with talk back facility with store enamel painted M.S.Sheet hosing etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach2977.732977.736.0FalseNoneNoneFalseNoneFalse17866.380
3647266132951NoneItem 1.2.1SupplyingheavygaugePVCconduitpipe......mmdia..........mmthickconfirmingtoIS2509withsuitablesizebends,metal/PVCJunctionboxes,adhesivepasteetc.,andrunningbeforeconcretingtheslab.TheconduitshouldbetiedtothereinforcementrodsbyusingbindingwiresandunusedwaysofjunctionboxesandpipeendsshouldbecoveredusingPVCendenclosures,runwith18SWGGIfishwirewherever necessary(19/20 mm dia 2 mm thick) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr83.8683.86900.0FalseNoneNoneFalseNoneFalse75474.00
3647267132951NoneItem 2.3.2Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 (1.5 mm2) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr31.631.61800.0FalseNoneNoneFalseNoneFalse56880.00
3647268132951NoneItem 15.66.1Supply, install, test and commissioning of addressable peer to peer Networkable analogue addressable type fire alarm control panel with minimum 1500 Character /240X64 Pixel / 7inch Touchscreen graphic LCD display. The panel should be equipped with sufficient numbers of loop with 20% spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 126/240 detectors/ devices in any combination with key pad, dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NAC's, min 20 programmable Zonal LEDs and operates on 240V AC + 10% with 50Hz with built in charger. The panel shall have fire, fault relays, option of BMS integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, Class 'X' wiring with provision of both class 'A' and class 'B' wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels/ Nodes in one network with all other accessories required to successfully run the system. (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design). Approval: VDS/UL/EN-54 Std.2 Loop Panel ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach255234.0255234.03.0FalseNoneNoneFalseNoneFalse765702.00
3647269132951NoneItem Least Quotation RateSupply, intallation, testing and Commissioning of Graphical software for entire fire alarm panels including detector configuration, commissioning etc ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach243822.61243822.611.0FalseNoneNoneFalseNoneFalse243822.610
3647270132951NoneItem Least Quotation RateSupply, intallation, testing and Commissioning of Network card for fire alram panels integration ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach88500.088500.01.0FalseNoneNoneFalseNoneFalse88500.00
3647271132951NoneItem 15.103Supplying Installing, testing and commissioning of Response Indicator constists of twin LED wioth electronic circutarx work on 24 DC enclose in PVC retangular. complete including cost of materials, labour, HOM complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach303.84303.8450.0FalseNoneNoneFalseNoneFalse15192.00
3647272132951NoneItem 15.67Supply, Installation , Testing & Commissioning  of Network Active Repeater Panel with 1500 Character / 240X64 Pixel / 7inch Touchscreen. The LCD shall Display all events / detectors, devices status of complete systems in the networked.  Approval: UL/VDS/EN54. Make: ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach79001.079001.01.0FalseNoneNoneFalseNoneFalse79001.00
3647273132951NoneItem 15.66Supply, intallation, testing and Commissioning of loop card ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3403.123403.123.0FalseNoneNoneFalseNoneFalse10209.360
3647274132951NoneItem 15.69Supply Installation testing & Commissioning of analog addressable electric smoke sensor with flashing LED capable of woking at 9V to 33 V DC .The Optical Smoke Detector is unaffected by wind or atmosphericpressure and operates over the temperature range -20C to +60C. IP Rating at IP 23D & Approval with EN-54 -7, LPCB Approved. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4010.814010.81250.0FalseNoneNoneFalseNoneFalse1002702.50
3647275132951NoneItem Least Quotation RateSITC OF Fault isolation module:- Supply, Erection,Testing and Commissioning of UL-APPROVED Analog addressable fault isolator circuit modules of wall mounted type with mounting accessories. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7080.07080.016.0FalseNoneNoneFalseNoneFalse113280.00
3647276132951NoneItem 15.68Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Sounder & Beacon  with inbuilt isolator and  having Min 15 distinct sound patterns/ multitone to indicate Exit doors and direct occupants for safe and fast evacuation and 100dB output with minimum 1Hz Frequency flash rate designed for IP65 requirements and approved to operate in 10C to +55C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: VDS/UL/EN54. Make: Advanced (UK),Simplex, Notifier,Argus(Uk) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach5955.465955.466.0FalseNoneNoneFalseNoneFalse35732.760
3647277132951NoneItem 15.73Supplying Installing, testing and commissioning of Resettable type Manual Call point . works on 24V DC LED indicator with glass Fronted. Fire Symbol .The red Manual Call Point is approved to EN54-11 standard. MECHANICAL CONSTRUCTION The component parts of the call point are moulded in polycarbonate or ABS, depending on their function. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3646.23646.26.0FalseNoneNoneFalseNoneFalse21877.20
3647278132951NoneItem 1.4.2Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.100 x 75 x 65 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach143.41143.41250.0FalseNoneNoneFalseNoneFalse35852.50
3647279132951NoneItem 15.72Supply, install, test and commissioning of Analogue addressable Monitor Cum Control (Input/Output) module (1+1) with inbuilt relay and isolator with LED indicator, approved to operate in 10C to +55C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. In case of Manufacturer with single Input or Output module need to supply One quantity of each for line item.(For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: EN54. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4740.054740.056.0FalseNoneNoneFalseNoneFalse28440.30
3647280132951NoneItem 15.105Supplying and drawing of 2 Core X 1.5 Sqmm copper conductor armoured cable ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr182.31182.312000.0FalseNoneNoneFalseNoneFalse364620.00
3647281132951NoneItem 15.113SITC of 7AM-12 V Battery for fire alarm system ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1301.691301.696.0FalseNoneNoneFalseNoneFalse7810.140
17223352660000NoneNoneBuildingsTLH SHIRAHATTI CIVIL GF ( Including quarters,mortury,and allied works)130089816.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3647282132952NoneItem 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm477.65477.6589.102FalseNoneNoneFalseNoneFalse42559.57030
3647283132952NoneItem 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum115.46115.463201.59FalseNoneNoneFalseNoneFalse369655.58140
3647284132952NoneItem 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum123.97123.974263.337FalseNoneNoneFalseNoneFalse528525.887890
3647285132952NoneItem 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum441.19441.19757.544FalseNoneNoneFalseNoneFalse334220.837360
3647286132952NoneItem 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum516.54516.54272.457FalseNoneNoneFalseNoneFalse140734.938780
3647287132952NoneItem 1.1ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum164.07164.072517.656FalseNoneNoneFalseNoneFalse413071.819920
3647288132952NoneItem 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm143.41143.412635.637FalseNoneNoneFalseNoneFalse377976.702170
3647289132952NoneItem 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum323.29323.293119.4287FalseNoneNoneFalseNoneFalse1008480.1044230
3647290132952NoneItem 1.8Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum576.09576.092460.056FalseNoneNoneFalseNoneFalse1417213.661040
3647291132952NoneItem 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7279.037279.03488.0422FalseNoneNoneFalseNoneFalse3552473.8150660
3647292132952NoneItem 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates:FOOTINGS-8% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8316.838316.831023.47FalseNoneNoneFalseNoneFalse8512026.00010
3647293132952NoneItem 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates:PEDESTALS-10% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8470.858470.8539.196FalseNoneNoneFalseNoneFalse332023.43660
3647294132952NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:COLUMNS-70% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum14138.8614138.86227.21FalseNoneNoneFalseNoneFalse3212490.38060
3647295132952NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:PLINTH BEAM-50% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12475.4712475.47711.38FalseNoneNoneFalseNoneFalse8874799.84860
3647296132952NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:RCC BEAMS-60% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13307.1713307.17306.14FalseNoneNoneFalseNoneFalse4073857.02380
3647297132952NoneItem 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork-PCC 45% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11684.2411684.2429.754FalseNoneNoneFalseNoneFalse347652.876960
3647298132952NoneItem 8.16 aProviding lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1504.661504.6647.37FalseNoneNoneFalseNoneFalse71275.74420
3647299132952NoneItem 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget108726.03108726.03256.1185FalseNoneNoneFalseNoneFalse27846747.7145550
3647300132952NoneItem 5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7765.197765.1951.14FalseNoneNoneFalseNoneFalse397111.81660
3647301132952NoneItem 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1592.171592.173136.34FalseNoneNoneFalseNoneFalse4993586.45780
3647302132952NoneItem 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1341.81341.8339.82FalseNoneNoneFalseNoneFalse455970.4760
3647303132952NoneItem 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum120099.75120099.754.63FalseNoneNoneFalseNoneFalse556061.84250
3647304132952NoneItem 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1234.841234.8464.0FalseNoneNoneFalseNoneFalse79029.760
3647305132952NoneItem 22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo668.46668.46128.0FalseNoneNoneFalseNoneFalse85562.880
3647306132952NoneItem 22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo455.77455.7764.0FalseNoneNoneFalseNoneFalse29169.280
3647307132952NoneItem 22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo182.31182.31120.0FalseNoneNoneFalseNoneFalse21877.20
3647308132952NoneItem 22.15.9Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo85.0785.07221.0FalseNoneNoneFalseNoneFalse18800.470
3647309132952NoneItem 22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo121.53121.5364.0FalseNoneNoneFalseNoneFalse7777.920
3647310132952NoneItem 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1278.61278.664.0FalseNoneNoneFalseNoneFalse81830.40
3647311132952NoneItem 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos72.9272.92384.0FalseNoneNoneFalseNoneFalse28001.280
3647312132952NoneItem 20.79Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr63.263.2429.29FalseNoneNoneFalseNoneFalse27131.1280
3647313132952NoneItem 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4037.554037.55181.07FalseNoneNoneFalseNoneFalse731079.17850
3647314132952NoneItem 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm8184.58184.5143.445FalseNoneNoneFalseNoneFalse1174025.60250
3647315132952NoneItem 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6950.876950.8732.805FalseNoneNoneFalseNoneFalse228023.290350
3647316132952NoneItem 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg204.18204.183877.649FalseNoneNoneFalseNoneFalse791738.372820
3647317132952NoneItem 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem853.21853.21186.2FalseNoneNoneFalseNoneFalse158867.7020
3647318132952NoneItem 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4235.664235.6664.23FalseNoneNoneFalseNoneFalse272056.44180
3647319132952NoneItem 12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1353.951353.9565.0FalseNoneNoneFalseNoneFalse88006.750
3647320132952NoneItem 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKgs165.29165.29158.76FalseNoneNoneFalseNoneFalse26241.44040
3647321132952NoneItem 12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1200.811200.816245.0FalseNoneNoneFalseNoneFalse7499058.450
3647322132952NoneItem 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm379.2379.24623.812FalseNoneNoneFalseNoneFalse1753349.51040
3647323132952NoneItem 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm256.44256.444439.34FalseNoneNoneFalseNoneFalse1138424.34960
3647324132952NoneItem 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm121.53121.539063.158FalseNoneNoneFalseNoneFalse1101445.591740
3647325132952NoneItem 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm424.17424.171893.136FalseNoneNoneFalseNoneFalse803011.497120
3647326132952NoneItem 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm430.25430.25790.006FalseNoneNoneFalseNoneFalse339900.08150
3647327132952NoneItem 8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr46.1846.1810492.86FalseNoneNoneFalseNoneFalse484560.27480
3647328132952NoneItem 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr63.263.22276.96FalseNoneNoneFalseNoneFalse143903.8720
3647329132952NoneItem 9.17.2Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1428.091428.091224.84FalseNoneNoneFalseNoneFalse1749181.75560
3647330132952NoneItem 9.2Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 ce- ment : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 L per 50 kg of cement or as per direction of Engineer incharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm972.31972.31116.2FalseNoneNoneFalseNoneFalse112982.4220
3647331132952NoneItem 9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1611.621611.62483.023FalseNoneNoneFalseNoneFalse778449.527260
3647332132952NoneItem 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm358.54358.54931.6404FalseNoneNoneFalseNoneFalse334030.3490160
3647333132952NoneItem 9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3466.323466.32994.85FalseNoneNoneFalseNoneFalse3448468.4520
3647334132952NoneItem 10.18Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4082.524082.5278.45FalseNoneNoneFalseNoneFalse320273.6940
3647335132952NoneItem 9.3Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6475.656475.65245.981FalseNoneNoneFalseNoneFalse1592886.862650
3647336132952NoneItem 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3138.163138.16137.304FalseNoneNoneFalseNoneFalse430881.920640
3647337132952NoneItem 10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 m2 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4785.024785.0224.198FalseNoneNoneFalseNoneFalse115787.913960
3647338132952NoneItem 9.4Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1132.751132.7590.57FalseNoneNoneFalseNoneFalse102593.16750
3647339132952NoneItem 15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm747.47747.47165.209FalseNoneNoneFalseNoneFalse123488.771230
3647340132952NoneItem 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1080.491080.49100.69FalseNoneNoneFalseNoneFalse108794.53810
3647341132952NoneItem 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1761.111761.11424.4184FalseNoneNoneFalseNoneFalse747447.4884240
3647342132952NoneItem 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg686.7686.71268.24FalseNoneNoneFalseNoneFalse870900.4080
3647343132952NoneItem 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm154.35154.359063.158FalseNoneNoneFalseNoneFalse1398898.43730
3647344132952NoneItem 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm189.6189.61893.136FalseNoneNoneFalseNoneFalse358938.58560
3647345132952NoneItem 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm60.7660.76182.625FalseNoneNoneFalseNoneFalse11096.2950
3647346132952NoneItem 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm139.77139.77182.625FalseNoneNoneFalseNoneFalse25525.496250
3647347132952NoneItem 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm64.4164.41434.59FalseNoneNoneFalseNoneFalse27991.94190
3647348132952NoneItem 8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm822.82822.82434.59FalseNoneNoneFalseNoneFalse357589.34380
3647349132952NoneItem 5.44.1Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universalaluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -inCharge. (Material shall confirm to ASTM 6063). Floor Joint of 100 mm gap ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem5800.155800.1572.0FalseNoneNoneFalseNoneFalse417610.80
3647350132952NoneItem 5.45.1Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-InCharge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063) Wall Joint of 100 mm gap ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem4835.54835.572.0FalseNoneNoneFalseNoneFalse348156.00
3647351132952NoneItem 5.46.1Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed toaccommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). Roof Joint of 100 mm gap ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem5424.25424.2628.8FalseNoneNoneFalseNoneFalse3410736.960
3647352132952NoneItem 18.1Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg494.66494.66273.0FalseNoneNoneFalseNoneFalse135042.180
3647353132952NoneItem 18.3Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3698.463698.4642.0FalseNoneNoneFalseNoneFalse155335.320
3647354132952NoneItem 9.137Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm6444.956444.9531.32FalseNoneNoneFalseNoneFalse201855.8340
3647355132952NoneItem 9.136Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to bepaid for separately). ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem1462.751462.7584.6FalseNoneNoneFalseNoneFalse123748.650
3647356132952NoneItem 7.41Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2057.672057.67621.109FalseNoneNoneFalseNoneFalse1278037.356030
3647357132952NoneItem 7.31Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1548.411548.41266.19FalseNoneNoneFalseNoneFalse412171.25790
3647358132952NoneItem 10.1.1Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm4868.894868.8927.416FalseNoneNoneFalseNoneFalse133485.488240
3647359132952NoneItem 11.35.1.1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg549.36549.36113.16FalseNoneNoneFalseNoneFalse62165.57760
3647360132952NoneItem 11.36.1Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge: Pre- laminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1090.211090.214.715FalseNoneNoneFalseNoneFalse5140.340150
3647361132952NoneItem 11.37.1Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1200.811200.816.601FalseNoneNoneFalseNoneFalse7926.546810
3647362132952NoneItem 10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm291.69291.6910.0FalseNoneNoneFalseNoneFalse2916.90
3647363132952NoneItem 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg686.7686.795.55FalseNoneNoneFalseNoneFalse65614.1850
3647364132952NoneItem 15.11Newly Constructed Roof/Bathroom/Toilet/balcony/utility with Cementatius Waterproof coating Below 500 m2-Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface like Roof, bathroom, toilet, balcony & utility area applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break 120% as per ASTM D 412, Tensile strength 1N/mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm638.08638.0890.11FalseNoneNoneFalseNoneFalse57497.38880
3647365132952NoneItem 10.1.7Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr499.52499.5224.0FalseNoneNoneFalseNoneFalse11988.480
3647366132952NoneItem 1.4.1Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum294.12294.121283.372FalseNoneNoneFalseNoneFalse377465.372640
3647367132952NoneItem 4.11 AMaking 50 mm x 50 mm furrows, 25mm/ 50mm deep, 45 degrees to the center line of the road and at one metre interval in the existing thin bituminous wearing coarse including sweeping and disposal of excavated material.25 mm deep furrow cutting ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm9.729.723075.0FalseNoneNoneFalseNoneFalse29889.00
3647368132952NoneItem 3.7Compacting original ground supporting embankment-Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum127.61127.61461.25FalseNoneNoneFalseNoneFalse58860.11250
3647369132952NoneItem 3.1Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum103.31103.31418.5FalseNoneNoneFalseNoneFalse43235.2350
3647370132952NoneItem 4.2 VConstruction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 .For Grading -V Material ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum3022.693022.69307.5FalseNoneNoneFalseNoneFalse929477.1750
3647371132952NoneItem 4.17Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface andcompactingwithvibratoryrollertoachievethedesireddensity. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum3110.23110.2307.5FalseNoneNoneFalseNoneFalse956386.50
3647372132952NoneItem 5.1Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/m2 using mechanical means. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm49.8349.833075.0FalseNoneNoneFalseNoneFalse153227.250
3647373132952NoneItem 5.3Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broom ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm14.5814.583075.0FalseNoneNoneFalseNoneFalse44833.50
3647374132952NoneItem 5.6 AProviding and laying Bituminous Macadam with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG- 40 @ 3.3% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9429.079429.07230.625FalseNoneNoneFalseNoneFalse2174579.268750
3647375132952NoneItem 5.31Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12338.7412338.7483.25FalseNoneNoneFalseNoneFalse1027200.1050
3647376132952NoneItem 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7279.037279.0333.3FalseNoneNoneFalseNoneFalse242391.6990
3647377132952NoneItem 8.42.2Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)600 x 200 x 100 mm Kerb Stone ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr303.84303.841110.0FalseNoneNoneFalseNoneFalse337262.40
3647378132952NoneItem 4.19Construction of Median and Island above road level with approved material deposited at site from roadway cutting and excavation for drain and foundation of other structures, spread, graded and compacted as per clause 408 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum446.05446.05149.85FalseNoneNoneFalseNoneFalse66840.59250
3647379132952NoneItem 8.1Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm132.47132.47777.0FalseNoneNoneFalseNoneFalse102929.190
3647380132952NoneItem 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7279.037279.0317.7FalseNoneNoneFalseNoneFalse128838.8310
3647381132952NoneItem 2.5.3Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates: A. Raft ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8771.798771.7953.09FalseNoneNoneFalseNoneFalse465694.33110
3647382132952NoneItem 2.5.3Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates:pump room and sump tank-walls-10% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9367.939367.9343.45FalseNoneNoneFalseNoneFalse407036.55850
3647383132952NoneItem 2.5.3Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates:Cover slabs 50% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12774.4612774.4630.192FalseNoneNoneFalseNoneFalse385686.496320
3647384132952NoneItem 2.5.3Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates:D. beams- pumproom -60% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13626.0913626.095.078FalseNoneNoneFalseNoneFalse69193.285020
3647385132952NoneItem 2.5.3Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates:E. lintel-beam-60% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13626.0913626.091.9FalseNoneNoneFalseNoneFalse25889.5710
3647386132952NoneItem 2.5.3Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates:F. Staircase Steps- pumproom -50% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12774.4612774.464.9814FalseNoneNoneFalseNoneFalse63634.6950440
3647387132952NoneItem 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:for pumproom(45%) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm11684.2411684.240.1575FalseNoneNoneFalseNoneFalse1840.26780
3647388132952NoneItem 2.11 hSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget96029.9696029.9610.5706FalseNoneNoneFalseNoneFalse1015094.2951760
3647389132952NoneItem 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1592.171592.17126.48FalseNoneNoneFalseNoneFalse201377.66160
3647390132952NoneItem 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5442.565442.564.2FalseNoneNoneFalseNoneFalse22858.7520
3647391132952NoneItem 15.14UGT/OHT (inside) waterproofing with Anti-microbial Coating---Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification.GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2033.362033.36276.64FalseNoneNoneFalseNoneFalse562508.71040
3647392132952NoneItem 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm450.91450.91794.49FalseNoneNoneFalseNoneFalse358243.48590
3647393132952NoneItem 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm139.77139.775.64FalseNoneNoneFalseNoneFalse788.30280
3647394132952NoneItem 8.21Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm31.631.6377.0326FalseNoneNoneFalseNoneFalse11914.230160
3647395132952NoneItem 8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm108.17108.17377.0326FalseNoneNoneFalseNoneFalse40783.6163420
3647396132952NoneItem 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2384.612384.6112.0FalseNoneNoneFalseNoneFalse28615.320
3647397132952NoneItem 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7279.037279.0355.5FalseNoneNoneFalseNoneFalse403986.1650
3647398132952NoneItem 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates:Base slab (VENT PORTION)-5% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8732.838732.8344.4FalseNoneNoneFalseNoneFalse387737.6520
3647399132952NoneItem 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates:Side wall-35% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11227.9211227.9266.6FalseNoneNoneFalseNoneFalse747779.4720
3647400132952NoneItem 17.12Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1127.891127.89444.0FalseNoneNoneFalseNoneFalse500783.160
3647401132952NoneItem 2.11 hSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures:GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget96029.9696029.968.436FalseNoneNoneFalseNoneFalse810108.742560
3647402132952NoneItem 12.4Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indic ting the location of the site, recommended depth of casing pipe required seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casin pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging techn al personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of R . 100/- is to be deducted for Dry Borewell towards yield test. tc. complete. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6427.036427.031.0FalseNoneNoneFalseNoneFalse6427.030
3647403132952NoneItem 12.1.1Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth):Borewell depth of 0 to 50 Mtrs ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr449.69449.6950.0FalseNoneNoneFalseNoneFalse22484.50
3647404132952NoneItem 12.1.2Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth):Borewell depth of 50 to 100 Mtrs ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr563.94563.9450.0FalseNoneNoneFalseNoneFalse28197.00
3647405132952NoneItem 12.1.3Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth):Borewell depth of 100 to 150 Mtrs ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr599.19599.1950.0FalseNoneNoneFalseNoneFalse29959.50
3647406132952NoneItem 12.1.4Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth):Borewell depth of 150 to 200 Mtrs ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr695.2695.250.0FalseNoneNoneFalseNoneFalse34760.00
3647407132952NoneItem 12.1.5Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth):Borewell depth of 200 to 250 Mtrs ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr815.53815.5350.0FalseNoneNoneFalseNoneFalse40776.50
3647408132952NoneItem 12.1.6Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth):Borewell depth of 250 to 300 Mtrs ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr899.39899.3950.0FalseNoneNoneFalseNoneFalse44969.50
3647409132952NoneItem 12.1.7Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth):Borewell depth of 300 to 350 Mtrs ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr1054.961054.9650.0FalseNoneNoneFalseNoneFalse52748.00
3647410132952NoneItem 12.32Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 nd latest ammendments, electrical resistance welded steel tubes, terial and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixe with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr2349.362349.3635.0FalseNoneNoneFalseNoneFalse82227.60
3647411132952NoneItem 13.28Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr668.46668.4660.0FalseNoneNoneFalseNoneFalse40107.60
3647412132952NoneItem 12.33Providing and fixing MS casing collars per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thic ness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos182.31182.311.0FalseNoneNoneFalseNoneFalse182.310
3647413132952NoneItem 12.34Providing and laying at site of wor MS asing caps as per IS 1239 (part- II) 1982 with all latest amendm nts if any for any dia. The thickness of plate used for covering one e shall be 3mm (minimum). The dimensions of caps and olars shall be strictly as per IS 1239 (Part-II) 1982 with all mendments including cost of material and labour charges for fixing, if a y etc. complete with all lead and lifts and as directed by the Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos199.32199.321.0FalseNoneNoneFalseNoneFalse199.320
3647414132952NoneItem 13.81.3Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos255.23255.231.0FalseNoneNoneFalseNoneFalse255.230
3647415132952NoneItem 13Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo48.6248.62100.0FalseNoneNoneFalseNoneFalse4862.00
3647416132952NoneItem 13.13.6Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For HP etc Complete.5.00 HP - 90 LPM @ 110 m = 15 STG Outlet Dia - 2.00" ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach39059.339059.31.0FalseNoneNoneFalseNoneFalse39059.30
3647417132952NoneItem 13.23.2Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protectionsuitable for thepumpdescribedabove 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.3 to 6 HP pumps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach11607.0711607.071.0FalseNoneNoneFalseNoneFalse11607.070
3647418132952NoneItem 13.29Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSet1883.871883.871.0FalseNoneNoneFalseNoneFalse1883.870
3647419132952NoneItem 13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeJob7900.097900.091.0FalseNoneNoneFalseNoneFalse7900.090
3647420132952NoneItem 13.33Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeJob1640.791640.791.0FalseNoneNoneFalseNoneFalse1640.790
3647421132952NoneItem 2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr204.18204.18275.0FalseNoneNoneFalseNoneFalse56149.50
3647422132952NoneItem 5.42.2Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSq CM0.520.5230000.0FalseNoneNoneFalseNoneFalse15600.00
3647423132952NoneItem 5.44.4Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach17647.617647.61.0FalseNoneNoneFalseNoneFalse17647.60
3647424132952NoneItem 5.6.6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach396.37396.371.0FalseNoneNoneFalseNoneFalse396.370
3647425132952NoneItem 5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach504.39504.391.0FalseNoneNoneFalseNoneFalse504.390
3647426132952NoneItem 13.18.1Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling..15A to 63A TPST ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach337.88337.881.0FalseNoneNoneFalseNoneFalse337.880
3647427132952NoneItem 5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKvar583.39583.391.0FalseNoneNoneFalseNoneFalse583.390
3647428132952NoneItem 1.14.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 to 6 m.(90%) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum142.2142.280.802FalseNoneNoneFalseNoneFalse11490.04440
3647429132952NoneItem 1.15.3Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth exceeding 3m, but not exceeding 4.5m(10%) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum562.73562.738.978FalseNoneNoneFalseNoneFalse5052.189940
3647430132952NoneItem 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7279.037279.038.257FalseNoneNoneFalseNoneFalse60102.950710
3647431132952NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:BOTTOM SLAB-3% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8566.498566.4913.09FalseNoneNoneFalseNoneFalse112135.35410
3647432132952NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:RC WALL-10% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum9148.689148.6838.9FalseNoneNoneFalseNoneFalse355883.6520
3647433132952NoneItem 2.11 hSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget96029.9696029.967.07FalseNoneNoneFalseNoneFalse678931.81720
3647434132952NoneItem 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1592.171592.1736.34FalseNoneNoneFalseNoneFalse57859.45780
3647435132952NoneItem 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5442.565442.564.2FalseNoneNoneFalseNoneFalse22858.7520
3647436132952NoneItem 15.13STP (inside) waterproofing with Anticorrosive & Protective Coating--Providing and Applying two component coal tar epoxy-based coating on inside surface of Sewage & Effluent treatment tank @ 0.30 kg/m2 in 2 coats to achieve a DFT of 200 microns when fully cured. Ensure that this coating is applied over the protective plaster and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Scratch resistance, for 7kg load as per ASTM : D 7027 - 05, Chemical resistance, immersion in dilute acid alkali & salt solutions 7 days confirms to ASTM : C 868, Salt Spray resistance confirms to ASTM : B 117. The finished cost to include surface preparation completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm2023.642023.64262.69FalseNoneNoneFalseNoneFalse531589.99160
3647437132952NoneItem 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm139.77139.777.08FalseNoneNoneFalseNoneFalse989.57160
3647438132952NoneItem 8.21Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm115.46115.46410.804FalseNoneNoneFalseNoneFalse47431.429840
3647439132952NoneItem 8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm108.17108.1761.83FalseNoneNoneFalseNoneFalse6688.15110
3647440132952NoneItem 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2384.612384.6110.0FalseNoneNoneFalseNoneFalse23846.10
3647441132952NoneItem 11.2.6Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete:for 50 mm dia Medium duty ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr709.79709.7930.0FalseNoneNoneFalseNoneFalse21293.70
3647442132952NoneItem 11.2.7Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete:for 65mm dia Medium duty ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr873.87873.8712.0FalseNoneNoneFalseNoneFalse10486.440
3647443132952NoneItem 11.2.8Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete:for 80 mm dia Medium duty ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr1082.921082.9260.0FalseNoneNoneFalseNoneFalse64975.20
3647444132952NoneItem 11.3.9Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete:for 100mm dia Heavy duty ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr1716.141716.143.0FalseNoneNoneFalseNoneFalse5148.420
3647445132952NoneItem Least quatation rateProviding, Supplying and fixing 100 mm CI flanged puddle pipe thrust line hoisting confirming IS PRED SR page no 132/15(2) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo7798.627798.624.0FalseNoneNoneFalseNoneFalse31194.480
3647446132952NoneItem 13.31.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall :50 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr967.65967.6560.0FalseNoneNoneFalseNoneFalse58059.00
3647447132952NoneItem 13.6.4.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 50 mm nominal bore Horizontal ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo1686.271686.276.0FalseNoneNoneFalseNoneFalse10117.620
3647448132952NoneItem 13.6.6.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 80 mm nominal bore Horizontal ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo4421.994421.994.0FalseNoneNoneFalseNoneFalse17687.960
3647449132952NoneItem Least quatation rateKSRB-13-7.1-1 : Providing and fixing in position 100mm nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. KSRB-13-7.1-7 : do 100mm nominal bore KSRB-13-7.1-7 : do 100mm nominal bore (PWD SR 2018-19 Page No.95. It. No.13.58) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo3706.973706.972.0FalseNoneNoneFalseNoneFalse7413.940
3647450132952NoneItem Least quatation rateSupplying and fixing Bar Screen of size 1000 x 50mm & Bar of SS frame with 10 mm spacing ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo23600.023600.02.0FalseNoneNoneFalseNoneFalse47200.00
3647451132952NoneItem Least quatation RateSupplying and fixing Twin lobe roots blower of capacity 80 cum/hr @ 0.50 Kg/Cm2 with motors ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo220660.0220660.02.0FalseNoneNoneFalseNoneFalse441320.00
3647452132952NoneItem Least quatation Rate Supplying and fixing SS Laterals & EPDM Diffusers for SBR Bio Reactor ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo241900.0241900.02.0FalseNoneNoneFalseNoneFalse483800.00
3647453132952NoneItem Least quatation RateSupplying and fixing Coarse Diffusers of Disc type, , size 50MM, ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo6490.06490.06.0FalseNoneNoneFalseNoneFalse38940.00
3647454132952NoneItem Least quatation rateSupplying and fixing Pressurised Sand filter of MS construction with 50 NB frontal piping and valves with air safety valve, size 800 dia x 1250 HOS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo206500.0206500.01.0FalseNoneNoneFalseNoneFalse206500.00
3647455132952NoneItem Least quatation rateSupplying and fixing Activated Carbon Filter of MS construction with 50 NB frontal piping and valves with air safety valve, size 800 dia x 1250 HOS ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo224200.0224200.01.0FalseNoneNoneFalseNoneFalse224200.00
3647456132952NoneItem Least quatation rateSupplying and fixing Raw Effluent Pumps of size 2 HP, 3 Phase, to lift particle size of 25mm. Effluent transfer pumps one working & one standby for STP, ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo64900.064900.02.0FalseNoneNoneFalseNoneFalse129800.00
3647457132952NoneItem Least quatation RateSupplying and fixing Sludge Recirculation Pumps (2Nos. - 1 working &1 standby) :- ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo47200.047200.02.0FalseNoneNoneFalseNoneFalse94400.00
3647458132952NoneItem Least quatation rateSupplying and fixing Filter feed pumps of size(2 HP. 3PH, to lift particle size of 25mm)one working & one standby ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo47790.047790.02.0FalseNoneNoneFalseNoneFalse95580.00
3647459132952NoneItem Least quatation rateSupplying and fixing Chlorinator, online chlorine dosing system ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo37760.037760.01.0FalseNoneNoneFalseNoneFalse37760.00
3647460132952NoneItem Least quatation rateSupply and laying of foot valve 50 nb ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo3687.53687.52.0FalseNoneNoneFalseNoneFalse7375.00
3647461132952NoneItem Least quatation rateSupply and laying of Butterfly valves of 50NB, in delivery lines of delivery lines ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo2891.02891.022.0FalseNoneNoneFalseNoneFalse63602.00
3647462132952NoneItem Least quatation rateSupply and fixing of non compart mentalized motor control panel with PLC & HMI , Ultrasonic level sensors ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo359900.0359900.01.0FalseNoneNoneFalseNoneFalse359900.00
3647463132952NoneItem Least quatation rateSupply and laying of Electric copper cables of suitable capacity 4 core, 2.5 Sqmm with specials for all pumps ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem885.0885.085.0FalseNoneNoneFalseNoneFalse75225.00
3647464132952NoneItem Least quatation rateDecanting mechanism- Electricaly actuated motorised valve of 80 mm Dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
3647465132952NoneItem Least quatation rateInstrumentation & Automation - Flow meters, pr gauges, level switches ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo123900.0123900.01.0FalseNoneNoneFalseNoneFalse123900.00
3647466132952NoneItem Least quatation rateSupply and installation of Sludge dewatering system - centrifugal drier with SS basket ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNo123900.0123900.01.0FalseNoneNoneFalseNoneFalse123900.00
3647467132952NoneItem 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7279.037279.0314.25FalseNoneNoneFalseNoneFalse103726.17750
3647468132952NoneItem 2.11 hSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne96029.9696029.964.0707FalseNoneNoneFalseNoneFalse390909.1581720
3647469132952NoneItem 2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7556.147556.141.46FalseNoneNoneFalseNoneFalse11031.96440
3647470132952NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates:Column-70% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum14138.8614138.866.83FalseNoneNoneFalseNoneFalse96568.41380
3647471132952NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates:Footing-8% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum8982.348982.3420.12FalseNoneNoneFalseNoneFalse180724.68080
3647472132952NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates:Plinth Beam-50% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12475.4712475.4717.0FalseNoneNoneFalseNoneFalse212082.990
3647473132952NoneItem 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1592.171592.17131.4FalseNoneNoneFalseNoneFalse209211.1380
3647474132952NoneItem 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg165.29165.29388.8FalseNoneNoneFalseNoneFalse64264.7520
3647475132952NoneItem 8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm216.34216.34277.4FalseNoneNoneFalseNoneFalse60012.7160
3647476132952NoneItem 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7279.037279.034.645FalseNoneNoneFalseNoneFalse33811.094350
3647477132952NoneItem 8.18Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos909.11909.11290.333FalseNoneNoneFalseNoneFalse263944.633630
3647478132952NoneItem 11.56Fencing with G.I. barbed wire R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr14.5814.584340.0FalseNoneNoneFalseNoneFalse63277.20
3647479132952NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum14138.8614138.8627.87FalseNoneNoneFalseNoneFalse394050.02820
3647480132952NoneItem Data ratePreparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and proof checking by IISC/NIT/IIT only as decided by the Department and the same has to be furnished to the Department for approval and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering ,fire fighting works, CCTV, networking system, UPS system working drawings, MGPLS works, Modular OT, Lift system, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - etc., complete including all lead and lift and work to be executed as per the specification and engineer -in-charge of the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeJob4656000.04656000.01.0FalseNoneNoneFalseNoneFalse4656000.00
17223352660000NoneNoneBuildingsTLH SHIRAHATTI CIVIL Terrace works (Hospital and Quarters)10919010.65
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3647481132953NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:COLUMNS 70% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum14563.0514563.0537.125FalseNoneNoneFalseNoneFalse540653.231250
3647482132953NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:RCC BEAMS 60% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13706.4313706.4321.76FalseNoneNoneFalseNoneFalse298251.91680
3647483132953NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:RCC SLAB -50% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12849.7612849.7627.1437FalseNoneNoneFalseNoneFalse348790.0305120
3647484132953NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:LINTELS-60% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13706.7213706.723.215FalseNoneNoneFalseNoneFalse44067.10480
3647485132953NoneItem 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12035.2612035.261.87FalseNoneNoneFalseNoneFalse22505.93620
3647486132953NoneItem 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeTonne111987.89111987.8913.594FalseNoneNoneFalseNoneFalse1522363.376660
3647487132953NoneItem 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1639.941639.94484.6145FalseNoneNoneFalseNoneFalse794738.703130
3647488132953NoneItem 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm8430.118430.117.199FalseNoneNoneFalseNoneFalse60688.361890
3647489132953NoneItem 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg210.31210.31151.2FalseNoneNoneFalseNoneFalse31798.8720
3647490132953NoneItem 10.1.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5605.915605.919.0FalseNoneNoneFalseNoneFalse50453.190
3647491132953NoneItem 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm390.58390.58200.6325FalseNoneNoneFalseNoneFalse78363.041850
3647492132953NoneItem 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm264.14264.14358.98FalseNoneNoneFalseNoneFalse94820.97720
3647493132953NoneItem 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm125.18125.18559.61FalseNoneNoneFalseNoneFalse70051.97980
3647494132953NoneItem 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm436.9436.9856.85FalseNoneNoneFalseNoneFalse374357.7650
3647495132953NoneItem 15.12Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2. Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo-textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 85%, Tensile strength 2 Mpa as per ASTM D 412, Elongation at break 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo-textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1458.411458.412126.17FalseNoneNoneFalseNoneFalse3100827.58970
3647496132953NoneItem 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm158.98158.98559.6155FalseNoneNoneFalseNoneFalse88967.672190
3647497132953NoneItem 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm195.29195.29856.85FalseNoneNoneFalseNoneFalse167334.23650
3647498132953NoneItem 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm62.6462.6416.2FalseNoneNoneFalseNoneFalse1014.7680
3647499132953NoneItem 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm144.0144.016.2FalseNoneNoneFalseNoneFalse2332.80
3647500132953NoneItem 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter rainwater pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem364.29364.29185.99FalseNoneNoneFalseNoneFalse67754.29710
3647501132953NoneItem 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg184.02184.021218.24FalseNoneNoneFalseNoneFalse224180.52480
3647502132953NoneItem 7.34Providing and fixing 6mm Clear/opal white/solar bronze /blue/green tinted Multi wall poly carbonate sheet for Tubular structure. The work including cost of all materials, labour charges and usage charges of machinery for cutting, welding, grinding and erection equipments, with all lead, transportation, loading and unloading and all other incidental charges etc. complete as per specification and directions of the Engineer in charge of the work. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm3912.113912.1119.8FalseNoneNoneFalseNoneFalse77459.7780
3647503132953NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:COLUMNS-70% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum14280.2514280.254.14FalseNoneNoneFalseNoneFalse59120.2350
3647504132953NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:RCC BEAMS-60% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13440.2413440.243.82FalseNoneNoneFalseNoneFalse51341.71680
3647505132953NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:RCC SLAB-50% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum12600.2212600.224.58FalseNoneNoneFalseNoneFalse57709.00760
3647506132953NoneItem 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork:LINTELS-60% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13440.2413440.241.477FalseNoneNoneFalseNoneFalse19851.234480
3647507132953NoneItem 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork: Terrace floor stair case-45% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum11801.0911801.091.1347FalseNoneNoneFalseNoneFalse13390.6968230
3647508132953NoneItem 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharget109813.29109813.293.266FalseNoneNoneFalseNoneFalse358650.205140
3647509132953NoneItem 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm1608.091608.09264.38FalseNoneNoneFalseNoneFalse425146.83420
3647510132953NoneItem 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm8266.348266.345.399FalseNoneNoneFalseNoneFalse44629.969660
3647511132953NoneItem 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg206.22206.22113.39FalseNoneNoneFalseNoneFalse23383.28580
3647512132953NoneItem 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5496.985496.986.72FalseNoneNoneFalseNoneFalse36939.70560
3647513132953NoneItem 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm382.99382.99101.21FalseNoneNoneFalseNoneFalse38762.41790
3647514132953NoneItem 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm259.01259.0163.2002FalseNoneNoneFalseNoneFalse16369.4838020
3647515132953NoneItem 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm122.75122.75164.4127FalseNoneNoneFalseNoneFalse20181.6589250
3647516132953NoneItem 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm428.41428.41567.256FalseNoneNoneFalseNoneFalse243018.142960
3647517132953NoneItem 15.11Newly Constructed Roof/Bathroom/Toilet/balcony/utility with Cementatius Waterproof coating - Below 500 m2-Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface like Roof, bathroom, toilet, balcony & utility area applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break 120% as per ASTM D 412, Tensile strength 1N/mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm644.46644.46525.37FalseNoneNoneFalseNoneFalse338579.95020
3647518132953NoneItem 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm155.89155.89132.9427FalseNoneNoneFalseNoneFalse20724.4375030
3647519132953NoneItem 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm191.49191.49567.256FalseNoneNoneFalseNoneFalse108623.851440
3647520132953NoneItem 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm61.3761.3711.7FalseNoneNoneFalseNoneFalse718.0290
3647521132953NoneItem 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm141.16141.1611.7FalseNoneNoneFalseNoneFalse1651.5720
3647522132953NoneItem 10.1.7Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3:rainwater pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeRmtr504.52504.5263.0FalseNoneNoneFalseNoneFalse31784.760
3647523132953NoneItem 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork::Dummy Column-70% ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum13835.7613835.768.37FalseNoneNoneFalseNoneFalse115805.31120
3647524132953NoneItem 2.1.6Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeCum7815.377815.37106.31FalseNoneNoneFalseNoneFalse830851.98470
17223352660000NoneNoneBuildingswater supply and sanitation for Quarters and mortury1657444.02
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3647525132954NoneItem 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines DQ GF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem369.48369.4831.0FalseNoneNoneFalseNoneFalse11453.880
3647526132954NoneItem 13.50.6Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem469.14469.1420.0FalseNoneNoneFalseNoneFalse9382.80
3647527132954NoneItem 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes DQ GF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem351.25351.25109.0FalseNoneNoneFalseNoneFalse38286.250
3647528132954NoneItem 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 110mm nominal dia pipes DQ GF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem467.92467.9290.0FalseNoneNoneFalseNoneFalse42112.80
3647529132954NoneItem 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter DQ GF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem239.43239.4390.0FalseNoneNoneFalseNoneFalse21548.70
3647530132954NoneItem 13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter DQ GF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem353.68353.6835.0FalseNoneNoneFalseNoneFalse12378.80
3647531132954NoneItem 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete DQ GF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach296.55296.5560.0FalseNoneNoneFalseNoneFalse17793.00
3647532132954NoneItem 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach1482.781482.789.0FalseNoneNoneFalseNoneFalse13345.020
3647533132954NoneItem 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos339.09339.098.0FalseNoneNoneFalseNoneFalse2712.720
3647534132954NoneItem 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6760.056760.058.0FalseNoneNoneFalseNoneFalse54080.40
3647535132954NoneItem 14.40.2Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach602.83602.838.0FalseNoneNoneFalseNoneFalse4822.640
3647536132954NoneItem 14.38Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach176.23176.238.0FalseNoneNoneFalseNoneFalse1409.840
3647537132954NoneItem 13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach753.54753.5453.0FalseNoneNoneFalseNoneFalse39937.620
3647538132954NoneItem 14.44Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting,of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach13641.6413641.644.0FalseNoneNoneFalseNoneFalse54566.560
3647539132954NoneItem 14.10.1.1Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (510x1040 mm bowl depth 250 mm) DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6828.116828.118.0FalseNoneNoneFalseNoneFalse54624.880
3647540132954NoneItem 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach3745.863745.869.0FalseNoneNoneFalseNoneFalse33712.740
3647541132954NoneItem 14.63aProviding and fixing Single lever sink mixer with swivel spout top outlet wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach4578.414578.416.0FalseNoneNoneFalseNoneFalse27470.460
3647542132954NoneItem 13.15Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos881.16881.1618.0FalseNoneNoneFalseNoneFalse15860.880
3647543132954NoneItem 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge.DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach984.47984.4719.0FalseNoneNoneFalseNoneFalse18704.930
3647544132954NoneItem 13.8.1.1Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach100.87100.8719.0FalseNoneNoneFalseNoneFalse1916.530
3647545132954NoneItem 14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach371.91371.9119.0FalseNoneNoneFalseNoneFalse7066.290
3647546132954NoneItem 14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach109.38109.3819.0FalseNoneNoneFalseNoneFalse2078.220
3647547132954NoneItem 13.28Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 15 mm nominal bore, weighing not less than 32 g DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos77.7877.7865.0FalseNoneNoneFalseNoneFalse5055.70
3647548132954NoneItem 13.2.1Providing and fixing brass bib cock of approved quality :15 mm nominal bore DQ GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos347.6347.620.0FalseNoneNoneFalseNoneFalse6952.00
3647549132954NoneItem 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. DQ GROUND FLOOR :15 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem375.55375.5571.0FalseNoneNoneFalseNoneFalse26664.050
3647550132954NoneItem 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. DQ GROUND FLOOR :20 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem460.63460.6390.0FalseNoneNoneFalseNoneFalse41456.70
3647551132954NoneItem 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. DQ GROUND FLOOR :25 mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem579.74579.7460.0FalseNoneNoneFalseNoneFalse34784.40
3647552132954NoneItem 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. DQ GROUND FLOOR :32 mm nominal dia pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem676.97676.9740.0FalseNoneNoneFalseNoneFalse27078.80
3647553132954NoneItem 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work( Shafts & Terrace) DQ GROUND FLOOR :25 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem359.75359.75125.0FalseNoneNoneFalseNoneFalse44968.750
3647554132954NoneItem 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work( Shafts & Terrace) DQ GROUND FLOOR :50 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem876.3876.3285.0FalseNoneNoneFalseNoneFalse249745.50
3647555132954NoneItem 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore DQ GF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos403.51403.5126.0FalseNoneNoneFalseNoneFalse10491.260
3647556132954NoneItem 13.4.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) DQ GF :32 mm nominal bore ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos721.94721.9443.0FalseNoneNoneFalseNoneFalse31043.420
3647557132954NoneItem 13.4.4Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) DQ GF :50 mm nominal bore ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1039.161039.1614.0FalseNoneNoneFalseNoneFalse14548.240
3647558132954NoneItem ELE 7.3.2Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding.200 L Capacity DQ GF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach57019.2757019.273.0FalseNoneNoneFalseNoneFalse171057.810
3647559132954NoneItem 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.DQ GF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargel10.9310.935000.0FalseNoneNoneFalseNoneFalse54650.00
3647560132954NoneItem 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.DQ GF ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeKg178.66178.6650.0FalseNoneNoneFalseNoneFalse8933.00
3647561132954NoneItem Data rateProviding, fixing, testing and commissioning of Air Vent Cowel 110mm DQ MR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos219.48219.488.0FalseNoneNoneFalseNoneFalse1755.840
3647562132954NoneItem Data rateProviding, fixing, testing and commissioning of Air Vent Cowel 75mm DQ MR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos189.98189.9814.0FalseNoneNoneFalseNoneFalse2659.720
3647563132954NoneItem Data RateDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.DG MR:Core cut-75mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos1627.221627.2216.0FalseNoneNoneFalseNoneFalse26035.520
3647564132954NoneItem Data RateDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.DG MR:Core cut-110mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2370.622370.6240.0FalseNoneNoneFalseNoneFalse94824.80
3647565132954NoneItem Data RateDrilling with core cutting machine in RCC beams, slabs,floors etc., for alying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfication of the owner or his authorised representative etc., including nominal reniforcement wherever required complete. The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes.DG MR:Core cut-160mm dia ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2816.662816.668.0FalseNoneNoneFalseNoneFalse22533.280
3647566132954NoneItem Data RateProviding, fixing, testing and commissioning CP grating for trap, complete as directed by the Engineer in charge & approved quality confiMing to ISI or BIS Standards DQ MR ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos177.0177.045.0FalseNoneNoneFalseNoneFalse7965.00
3647567132954NoneItem Data rateSupplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) DQ MR GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos9318.469318.465.0FalseNoneNoneFalseNoneFalse46592.30
3647568132954NoneItem Data rateSupplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. (Jaguar make or Equalent) DQ MR GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos2183.02183.09.0FalseNoneNoneFalseNoneFalse19647.00
3647569132954NoneItem Market RateSupplying and fixing PCC Pedestal 450 x 250 x 200mm with MS sloted angle iron brackets, supports with necessary drilling holes to suit the insertion of pipe clamps deburning etc., as per detailed drawing for supporting water supply pipes with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls / outer walls etc. The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08mm thick conformed to IS 1239 etc., complete as directed by the employer. DQ MR GF Toilet ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeNos767.0767.0105.0FalseNoneNoneFalseNoneFalse80535.00
3647570132954NoneItem 13.16Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :: W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach7264.447264.445.0FalseNoneNoneFalseNoneFalse36322.20
3647571132954NoneItem 13.28Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeSqm5233.515233.515.0FalseNoneNoneFalseNoneFalse26167.550
3647572132954NoneItem 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem651.45651.4550.0FalseNoneNoneFalseNoneFalse32572.50
3647573132954NoneItem 13.33.6Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work Shafts & Terrace 40 mm nominal dia Pipes ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargem579.74579.7460.0FalseNoneNoneFalseNoneFalse34784.40
3647574132954NoneItem 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer inchargeEach6176.666176.662.0FalseNoneNoneFalseNoneFalse12353.320
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17223352670000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17223352670000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17223352670001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders end.None
17223352670000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17223352670000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17223368560000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17223369000000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17223369630000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17223369850000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete mannerNone
17223370200000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to timeNone
17223370690000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17223370880000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tenderNone
17223371200000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17223371610000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17223371820000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of executionNone
17223372050000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified timeNone
17223372310000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
17223372470000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the workNone
17223372680000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17223372810001NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GSTNone
17223372950000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid documentNone
17223373270000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the workNone
17223373450000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2019-20, 2020-21, 2021-22 , 2022-23 & 2023-24None
17223373700000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsiveNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24). Executed in any one financial year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation -8090.00 Cum,2)RCC and PCC -3845.00 Cum 3)Steel Reinforcement for RCC work- 389.00 Tonnes 4)BBM/Cement concrete Block Masonry/Solid Block Masonry/-7910.00 Sqm 5)Flooring/Dadooing (Vitrified/ Granite/ Ceramic/ Cement concrete/cladding/ dadooing) -7200.00 Sqm, 6)Plastering-26930.00 Sqm,7)Painting -24190.00 Sqm (8)MS grill- 6580.00 Kg, 9)WPC - 2467.00 sqm, Lift-01 No, Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (c).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.202.00 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d). The letter of willingness of the sub contractor to be engaged for electrical works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneClause 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.85.00 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e). The letter of willingness of the sub contractor to be engaged for water Supply works should be obtained and uploaded in the e-portalPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneClause 3.2(f) The Tenderer or his identified sub-contractor should have executed similar Fire Fighting works totaling to Rs.68.00 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (f). The valid license and letter of willingness of the sub contractor to be engaged for Fire Fighting works should be obtained and uploaded in the e-portalPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneClause 3.2(g) The Tenderer or his identified sub-contractor should have executed similar MGPLS works totaling to Rs.80.00 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (g). The valid license and letter of willingness of the sub contractor to be engaged for MGPLS works should be obtained and uploaded in the e-portalPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneClause 3.2(h) The Tenderer or his identified sub-contractor should have executed similar Modular OT works totaling to Rs.29.00 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (h). The valid license and letter of willingness of the sub contractor to be engaged for Modular OT works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneClause 3.2(i) The Tenderer or his identified sub-contractor should have executed similar Furniture works totaling to Rs.45.00 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (i). The valid license & letter of willingness of the sub contractor to be engaged for Furniture works should be obtained and uploaded in the e-portalPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneKPWD Class-IRegistration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- KPWD Class-1 Registration Certificate
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been Satisfactorily completed at least one Similar work of value not less than Rs.1601.50 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate should be issued by the Officer not less than the rank of Executive Engineer
NoneNoneNoneNoneClause ITT 3.3 (a)Equipment capacity Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50% can be deployed on ease/hire basis for all works provided, the relevant documents (commitment agreements etc.,) for availability for this work are furnished. Sl.No. Description of Equipment Quantity 1Self loading Concrete Mixer / Concrete Mixer Min 10 cft capacity -2 Nos. 2. Tipper-2 Nos, 3.Hydraulic Excavator-1 No. 4. Centering sheets-1500 sqmtr 5.Water tanker-2 Nos, 6.Bar Bending machine -2 Nos 7 Generator-1NoCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Receipt and Invoice to be furnished
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No,Position Qualification and Requirement No Of Persons 1)Project Manager BE Civil with minimum experience of 15 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years -1 One No, 2)Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years -1 One No 3)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years-1 One No. 4) Site Engineer -QA QC- B.E. Civil with minimum experience of 5 years in the Construction of buildings with QA QC.OR Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings with QA QC - 1 One No. Note: Degree certificate and Experience Certificate to be furnishedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Degree certificate and Experience Certificate to be furnished.
NoneNoneNoneNoneClause ITT 3.2(a): To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2019-20 to 2023-24) The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.4271.00 Lakhs. Note : a) For Clause 3.2 (a) the Turnover certificate and Balance sheet along with UDIN No duly certified by the charted accountant is to be submittedFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.641.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2019-20 to 2023-24 updated to 2024-25 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2024-25 price level, of existing commitments and ongoing works to be completed during the next 18 months. Note:The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent. certificate issued by the officer not less than the rank of Executive Engineer Ongoing commitments and Bids submitted for the works.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by the officer not less than the rank of Executive Engineer Ongoing commitments and Bids submitted for the works
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
PWD Class-I Registration certificate issued by Chief Engineer PWDTrueTechnical Bid
Annual Turnover Certificate & balance sheets certified by Chartered AccountantTrueTechnical Bid
Workdone certificate issued by the Officer not below the rank of Executive EngineerTrueTechnical Bid
Tenderer should have latest GST Registration, PAN Card and latest 3 GST clearance certificate in their name.TrueTechnical Bid
Tenderer should have ESI & PF Certificates his/firm name and PF paid receipt of last month.TrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1722343454000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, Arogya Soudha, 3rd floor, Leprosy Hospital premises, 1st cross, Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone