createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1722405777930
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd32500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose16-08-2024 16:00:00
tenderQueryClose14-08-2024 15:00:00
technicalBidOpen17-08-2024 16:10:00
publishedDate31-07-2024 16:56:36
publishedByPostRDPR_EE_DIV_BNGU
publishedByUserKPE12771 - H HARISH KUMAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonH HARISH KUMAR
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08026716046
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1722405778007
version6
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT7391
titleConstruction of Store Room above Health Sub Center in Doddagubbi Village, Doddagubbi Gram Panchayath, Bangalore East Taluk. Under Deposit Contribution Grants
descriptionConstruction of Store Room above Health Sub Center in Doddagubbi Village, Doddagubbi Gram Panchayath, Bangalore East Taluk. Under Deposit Contribution Grants
categoryWORKS
categoryTextWorks
ecv1293942.85
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location814
locationNameRDPR Division Office Bengaluru Urban
provisionalAmount1300000.0
groupOverheadTotal0.0
fileNumberAEE/EAST/DODDAGUBBI/13-00LAKHS
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17224057780000NoneNoneBuildingsConstruction of Store Room above Health Sub Center in Doddagubbi Village, Doddagubbi Gram Panchayath, Bangalore East Taluk. Under Deposit Contribution Grants1293942.85
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3654149133309NoneCode01Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Sqm1561.531561.53117.42FalseNoneNoneFalseNoneFalse183354.85260
3654150133309NoneCode02Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.COLUMNSCum14756.5814756.582.79FalseNoneNoneFalseNoneFalse41170.85820
3654151133309NoneCode03Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)es M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.LINTEL&BEAMCum13888.5513888.554.23FalseNoneNoneFalseNoneFalse58748.56650
3654152133309NoneCode04Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)es M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.ROOFCum13020.5213020.5215.38FalseNoneNoneFalseNoneFalse200255.59760
3654153133309NoneCode05Supplying, fitting and placing TMT FE 550/550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Tonne113476.21113476.212.64FalseNoneNoneFalseNoneFalse299577.19440
3654154133309NoneCode06Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Sqm267.66267.6699.5FalseNoneNoneFalseNoneFalse26632.170
3654155133309NoneCode07Providing 15 mm cement plaster on the rough side of single or half brick wall of mix: 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Sqm353.92353.92112.86FalseNoneNoneFalseNoneFalse39943.41120
3654156133309NoneCode08Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Sqm544.19544.19171.36FalseNoneNoneFalseNoneFalse93252.39840
3654157133309NoneCode09Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Sqm5680.345680.342.52FalseNoneNoneFalseNoneFalse14314.45680
3654158133309NoneCode10Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with Gl reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size-2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Sqm8542.088542.085.76FalseNoneNoneFalseNoneFalse49202.38080
3654159133309NoneCode11Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Kgs232.14232.14120.96FalseNoneNoneFalseNoneFalse28079.65440
3654160133309NoneCode12Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Sqm1490.491490.4998.9FalseNoneNoneFalseNoneFalse147409.4610
3654161133309NoneCode13Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Sqm126.85126.85212.36FalseNoneNoneFalseNoneFalse26937.8660
3654162133309NoneCode14Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer afterthoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Sqm173.79173.79212.36FalseNoneNoneFalseNoneFalse36906.04440
3654163133309NoneCode15Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Sqm112.9112.9171.36FalseNoneNoneFalseNoneFalse19346.5440
3654164133309NoneCode16Supplying and wiring adoption loop system in existing PVC Conduit/casing capping using2x1.55qmm (Phase& Neutral) amend some) (Earth wire) FRLS multistrand PVC insulated copperinda Samm toi-594 and latest amendments) with a 6Amps flush type SP control switch Class Room (confening the existing plastic sheet gang box, the other end of the wires sClass Room be terminated with uficient loose length in a wood/PVC round block.complete for each outlet. Medium point above 3 Mtrs up to 6 Mtrs from tapping point to out let via switch with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Point480.77480.772.0FalseNoneNoneFalseNoneFalse961.540
3654165133309NoneCode17Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary support ing back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Each173.79173.793.0FalseNoneNoneFalseNoneFalse521.370
3654166133309NoneCode18Supplying 6A flush/projected type socket and 6 amps flush/projected type SP switch either surface/flush moun ting in a existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessarycapacity wires as required 6 Amps 2 Way. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Each162.37162.378.0FalseNoneNoneFalseNoneFalse1298.960
3654167133309NoneCode19Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/ Stone/C.C wall. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Each404.66404.668.0FalseNoneNoneFalseNoneFalse3237.280
3654168133309NoneCode20Supplying 4mm thick plastic sheet with necessary nitches for fixing switches regulators etc., and fixing on existing wooden metal box using N.F. screws. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Sq CM0.520.52150.0FalseNoneNoneFalseNoneFalse78.00
3654169133309NoneCode21Supplying heavy gauge PVC condust pipe 20mm dia con firming to 19 2009 with suitable size bende junction boxes, adhesive paste etc, and fixing using inverted wood plugs in case of RCC celling and RCC wall stone struct ure or rawi plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700 mm using NF screws. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Mtr87.5387.53100.0FalseNoneNoneFalseNoneFalse8753.00
3654170133309NoneCode22Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary xing materials and 'C'Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required. 6-32 amps with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Each526.43526.431.0FalseNoneNoneFalseNoneFalse526.430
3654171133309NoneCode23Wiring for lighting/ power circute using one of PVC insula ted 1100v/grade multies and copper conductor single core cable in open or consealed system of win ng A Group materials 2.50 sqmm materials. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Mtr53.2853.2840.0FalseNoneNoneFalseNoneFalse2131.20
3654172133309NoneCode24Supplying and fixing PVC/metal conduit Deep junction box 32mm deep junction box. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Each77.3877.383.0FalseNoneNoneFalseNoneFalse232.140
3654173133309NoneCode25Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burninghours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Each875.27875.274.0FalseNoneNoneFalseNoneFalse3501.080
3654174133309NoneCode26Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, fo operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system 48" Sweep (1200 mm) Regular model. with all lead, lift, loading, unloading, labour, fuel, hire charges of machineries, equipments including all incidental charges as per detailed specifications etc., complete and as per directions of the Engineer in charge of the work.Each3785.23785.22.0FalseNoneNoneFalseNoneFalse7570.40
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17224057970000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17224057970000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17224057970001NoneNoneELIGIBILITYSubmission of insufficient documents required for Qualification of tender document as per K.W.1 of SBD will be technically dis-qualifiedNone
17224057970000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17224057970000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17224058170000NoneNoneELIGIBILITYPWD Department Registration DetailsNone
17224058260000NoneNoneELIGIBILITYIf the tenderers who have been failed to complete the work within the stipulated period in this Division pertaining to already entrusted works such tenderers will not entertainedNone
17224058300000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17224058360000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17224058410000NoneNoneELIGIBILITYthe tender bidders should furnish EMD as stipulated in tender Notification as furnished in Standard tender Bid Document K.W.1None
17224058450000NoneNoneELIGIBILITYthe available tender capacity will be calculated as stipulated in Sec-3 of KW-1 and Corrigendums.None
17224058490000NoneNoneELIGIBILITYEven though the tenderers meet the above criteria they are subject to be disqualified if they have made any misleading or false representations in the forms statements and attachments submitted in proof of the qualification requirements and or records of poor performance such as abandoning the works not properly completing the contract, inordinate delays in completion, litigation history or financial failures etc and or participated in the previous tender for the same work and had quoted unreasonably high tender prices and could not furnish rational justificationNone
17224058530000NoneNoneELIGIBILITYLabour cess will be deducted at 1% from Each Bill of the executed items from the Successful tenderers.None
17224058570000NoneNoneELIGIBILITYthe tenderer shall furnish all requisite details as per Standard Bid tender Document . they must carefully read all the tender conditions as stipulated in I.F.t and K.W.1 and relevant document shall be furnished. Otherwise tenders will be rejected.None
17224058620000NoneNoneELIGIBILITYCorrigendum pertaining to tender are applicable as per Government Circulars.None
17224058660000NoneNoneELIGIBILITYSuccessful tenderer has to make their own arrangement for procurement of all materials and machineries required for the work.None
17224058700000NoneNoneELIGIBILITYthe tenderer should complete the work within the stipulated period, otherwise Security Deposit amount will be forfeited .Action will be taken for black listing of such contractors.None
17224058730000NoneNoneELIGIBILITYthe Photos and Video graphs should be taken before commencement, during execution and after completion of the work in presence of nodal officersNone
17224058780000NoneNoneELIGIBILITYthe tenderers who meets all tender conditions stipulated inK.W.1 . are only eligibleNone
17224058810000NoneNoneELIGIBILITYthe undersigned reserves the Right to accept / reject any/ all tenders without assigning any reason.None
17224058850000NoneNoneELIGIBILITYthe defect liability period on contractor is one year from the date of completion of the work.None
17224058910000NoneNoneELIGIBILITYConditional tenders will be rejected.None
17224058940000NoneNoneELIGIBILITYthe work shall be implemented within the grants allotted by the Government.None
17224058980000NoneNoneELIGIBILITYContractor has to make their own arrangements for procurement of all materials and machineries required for the work. there is no departmental supply of materials. Contractor should procure materials and as defined in specifications prescribed in ISI and submit necessary quality control certificates from the authorized agencies before execution.None
17224059020000NoneNoneELIGIBILITYWithin 20 days of receipt of the letter of acceptance, the Successful tenderer shall deliver to the employer a security deposit in any of the forms given below for an amount equivalent to 5% of contract price plus additional security for un balanced tenders. Bankers cheque /DD/pay order in favour of EE Panchayath Raj Engineering Division, Bangalore Urban District, Bangalore/Specified small savings instrument pledged to EE Panchayath Raj Engineering Division, Bangalore Urban District, Bangalore otherwise the E.M.D. will be forfeited and necessary action will be initiated against the tenderer as per tender ClauseNone
17224059060000NoneNoneELIGIBILITYthe Furnished E.M.D. will be released only after successfully execution of the tender Agreement by the successful tenderer or 30 days from the date of submission of tender whichever is earlier.None
17224059090000NoneNoneELIGIBILITYEach item rates are inclusive of GST 18%. bidder should quote the rates inclusive of GST for each item.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNonePWD Registration Certificate- Class III and aboveCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneAnnual Turnover Certificate - CA with UDIN No. last five years period. 2019-20 to 2023-24Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneNOT APPLICABLEOthersNOT APPLICABLE
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersNOT APPLICABLE
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
NoneNoneNoneNoneNOT APPLICABLEOthersNOT APPLICABLE
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- NOT APPLICABLE
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate - CA with UDIN No. last five years period. 2019-20 to 2023-24TrueTechnical Bid
PWD Registration Certificate- Class III and aboveTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone