1721479168000 | 0 | None | None | Buildings | Construction of 10TPD Material Recovery Facility Building at Khanapur SK GP(Kulgeri cross) of Badami Taluk Bagalkot District | 12712685.53 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3569244 | 129500 | None | AEEBDM001 | SUB ESTIMATE FOR MRF MAIN BUILDING WITH KITCHEN Earth work excavation for Foundation by mechanical means for all works & depth upio 3 m, as per drawinga and technical specifications, including setting ont shoring, strutting, barricading caution lights, inchading dressing of excavated surfaces,disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m, and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtences requered to complete the work in ordinary/soft rock without blasting upto 1.5m depth [I.No,-I.I5.I/P-8 of PWD SR 2023-24 Volume 1] | Cum | 363.0 | 363.0 | 191.82 | False | None | None | False | None | False | 69630.66 | 0 | 3569245 | 129500 | None | AEEBDM002 | Providing and laying in position plain Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete thework as per technical specifications.Mix 1:3:6(M10) Using 40 mm nominal size graded crushed coarse aggregates.[I.No.-2.1.3/Page 15 of PWD SR 2023-24 Volume 1] | Cum | 5989.0 | 5989.0 | 153.28 | False | None | None | False | None | False | 917993.92 | 0 | 3569246 | 129500 | None | AEEBDM003 | Providing and laying in position reinforced Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticizers laid in finishedlayers, well compacted using needle vibrators, including all lead & lifts, costof all materials, quality confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M30 Design Mix Using 20 min nominal size graded crushed coarse aggregates Footing[I.No-2.2.5/Page 15 of PWD SR 2023-24] | Cum | 7018.92 | 7018.92 | 32.88 | False | None | None | False | None | False | 230782.0896 | 0 | 3569247 | 129500 | None | AEEBDM004 | Providing and laying in position reinforced Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticizers laid in finishedlayers, well compacted using needle vibrators, including all lead & lifts, costof all materials, quality confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M30 Design Mix Using 20 min nominal size graded crushed coarse aggregates [I.No-2.2.5/Page 15 of PWD SR 2023-24] Column Base | Cum | 7148.9 | 7148.9 | 8.09 | False | None | None | False | None | False | 57834.601 | 0 | 3569248 | 129500 | None | AEEBDM005 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifis, cost of all all materials, quality confirming to the requirements of relevant IS codes, labour. Usage charges of machinery, curing and all the other appartenances required to complete the work as per thechnical specifications. (The cost of steel reinforcement & formwork obe paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plinth Beem[I.No-2.2.5/Page 15 of PWD SR 2023-24] Volume-1 | Cum | 9748.5 | 9748.5 | 12.07 | False | None | None | False | None | False | 117664.395 | 0 | 3569249 | 129500 | None | AEEBDM006 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifis, cost of all all materials, quality confirming to the requirements of relevant IS codes, labour. Usage charges of machinery, curing and all the other appartenances required to complete the work as per thechnical specifications. (The cost of steel reinforcement & formwork obe paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Lintel[I.No-2.2.5/Page 15 of PWD SR 2023-24] Volume-1 | Cum | 10398.4 | 10398.4 | 0.95 | False | None | None | False | None | False | 9878.48 | 0 | 3569250 | 129500 | None | AEEBDM007 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing andtechnical specification Buildings [I.No-2.11a/Page 18 of PWD SR 2023-24] Volume-1 | Kg | 89.45 | 89.45 | 5621.4 | False | None | None | False | None | False | 502834.23 | 0 | 3569251 | 129500 | None | AEEBDM008 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) [I.No-5.4/Page 9 of PWD SR 2023-24] Volume-2 | Cum | 6389.0 | 6389.0 | 90.52 | False | None | None | False | None | False | 578332.28 | 0 | 3569252 | 129500 | None | AEEBDM009 | Filling approved earth (excluding rock) in trenches,
plinth, sides of foundations and other similar works etc.
in layers not exceeding 20cm in depth, consolidating
each deposited layer by ramming and watering, lead
up to 50 m and lift upto 1.5 m. [I.No-1.11/Page 35 of PWD SR 2023-24] Volume1 | Cum | 433.0 | 433.0 | 462.21 | False | None | None | False | None | False | 200136.93 | 0 | 3569253 | 129500 | None | AEEBDM010 | Providing and constructing load bearing wall with Solid Concrete blocksof size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. [I.No-6.32/Page17 of PWD SR 2023-24] Volume-2 | Cum | 1310.0 | 1310.0 | 67.55 | False | None | None | False | None | False | 88490.5 | 0 | 3569254 | 129500 | None | AEEBDM011 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) tobrick/stone masonry including rounding off corners wherever requiredsmooth rendering, providing and removing scaffolding, including cost ofmaterials, labour, curing complete as per specifications and as per directions
of Engineer-in-charge [I.No-8.3.1/Page41 of PWD SR 2023-24] Volume-2 | Sqm | 354.0 | 354.0 | 692.09 | False | None | None | False | None | False | 244999.86 | 0 | 3569255 | 129500 | None | AEEBDM012 | Providing and fixing Steel work in built up tubular (round, square orrectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer,including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes including cost of materials, labour, usagecharges of machinery complete as per specifications and as per directions
of the Engineer-in-Charge. [I.No-11.16.2/Page82 of PWD SR 2023-24] Volume-2 | Kg | 147.0 | 147.0 | 41120.3 | False | None | None | False | None | False | 6044684.1 | 0 | 3569256 | 129500 | None | AEEBDM013 | Providing and fixing precoated galvanised iron profile sheets (size, shape
and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+
0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277,in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheetand polyester top coat 15-18 microns. Sheet should have protective guardfilm of 25 microns minimum to avoid scratches during transportation andshould be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. [I.No-7.38/Page26 of PWD SR 2023-24] Volume-2 | Sqm | 568.0 | 568.0 | 2025.5 | False | None | None | False | None | False | 1150484.0 | 0 | 3569257 | 129500 | None | AEEBDM014 | Providing White washing with lime to give an even shade :New work (three
coats) with lime of approved quality, including cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge. [I.No-8.21/Page44 of PWD SR 2023-24] Volume-2 | Sqm | 26.0 | 26.0 | 692.09 | False | None | None | False | None | False | 17994.34 | 0 | 3569258 | 129500 | None | AEEBDM015 | Finishing with Deluxe Multi surface paint system for interiors and exteriors
using Primer as per manufacturers specifications: Two coats applied on
walls @ 1.25 L/10 m² over and including one coat of Special primer applied
@ 0.75 L/10 m² with paint of approved quality to give an even shade, after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree
angle with 10 years life) [I.No-8.33.1/Page46 of PWD SR 2023-24] Volume-2 | Sqm | 158.0 | 158.0 | 692.09 | False | None | None | False | None | False | 109350.22 | 0 | 3569259 | 129500 | None | AEEBDM016 | Providing and fixing aluminium work for doors, windows, ventilators
and partitions with extruded built up standard tubular sections/
appropriate sections and other sections of approved make conforming to
IS: 733 and IS:1285, fixing with dash fasteners of required dia and
size, including necessary filling up the gaps at junctions, i.e. at top,
bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat angle, Aluminium snap
beading for glazing / paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the directions of Engineer-incharge.(Glazing, paneling and dash fasteners to be paid for separately)
:For Fixed Portion: Powder coated aluminium (minimum thickness of
powder coating 50 micron) including cost of materials, labour, usage
charges of machinery complete as per specifications.[I.No-11.35.1.12 /Page87of PWD SR 2023-24] Volume-2 | Kg | 489.0 | 489.0 | 120.0 | False | None | None | False | None | False | 58680.0 | 0 | 3569260 | 129500 | None | AEEBDM017 | Providing and fixing 12 mm thick prelaminated particle board flat
pressed three layer or graded wood particle board conforming to IS: 12823
Grade l Type ll, in panelling fixed in aluminum doors, windows shutters
and partition frames with C.P. brass / stainless steel screws etc. complete
as per architectural drawings and directions of engineer- in-charge:
Pre-laminated particle board with decorative lamination on both sides
including cost of materials, labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge. [I.No-11.36.2 /Page89 of PWD SR 2023-24] Volume-2 | Sqm | 983.0 | 983.0 | 10.64 | False | None | None | False | None | False | 10459.12 | 0 | 3569261 | 129500 | None | AEEBDM018 | Providing and fixing glazing in aluminium door, window, ventilator
shutters and partitions etc. with EPDM rubber / neoprene gasket
etc. complete as per the architectural drawings and the directions of
engineer-in-charge . (Cost of aluminium snap beading shall be paid in
basic item):With float glass panes of 4.0 mm thickness (weight not less
than 10kg/ m²) including cost of materials, labour, usage charges of
machinery complete as per specifications and as per directions of the
Engineer-in-Charge. [I.No-11.37.1 /Page89 of PWD SR 2023-24] Volume-2 | Sqm | 988.0 | 988.0 | 7.6 | False | None | None | False | None | False | 7508.8 | 0 | 3569262 | 129500 | None | AEEBDM019 | Providing and laying 80mm thick factory made precast M -30
grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS
15658 for Commercial Traffic Axle load repetitions upto 10MSA
& for Residential Streets of approved shape and colour, laid in
required pattern and including over 40mm thick compacted bed
of coarse sand, filling the joints with fine sand etc. all complete as
per the direction of Engineer-in-charge. (WMM/WBM Base to be
paid separately as per relevant technical specification) [I.No-6.8.2 /Page51 of PWD SR 2023-24] Volume-3 | Sqm | 1161.0 | 1161.0 | 1026.92 | False | None | None | False | None | False | 1192254.12 | 0 | 3569263 | 129500 | None | AEEBDM020 | Supplying and fixing rolling shutters of approved make, made of required
size M.S. laths, interlocked together through their entire length and
jointed together at the end by end locks, mounted on specially
designed pipe shaft with brackets, side guides and arrangements for
inside and outside locking with push and pull operation complete,
including the cost of providing and fixing necessary 27.5 cm long wire
springs manufactured from high tensile steel wire of adequate strength
conforming to IS: 4454 - part 1 and M.S. top cover of required thickness
for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
including cost of materials, labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge. [I.No-11.6.1 /Page78 of PWD SR 2023-24] Volume-2 | Sqm | 2633.0 | 2633.0 | 50.0 | False | None | None | False | None | False | 131650.0 | 0 | 3569264 | 129500 | None | AEEBDM021 | Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for
operating rolling shutters including cost of materials, labour, usage charges
of machinery complete as per specifications and as per directions of the
Engineer-in-Charge.[I.No-11.8.4 /Page79 of PWD SR 2023-24] Volume-2 | Each | 24686.0 | 24686.0 | 2.0 | False | None | None | False | None | False | 49372.0 | 0 | 3569265 | 129500 | None | AEEBDM022 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6
mm angle iron and 3 mm M.S. gusset plates at the junctions and
corners, all necessary fittings complete, including applying a priming
coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonalbraces including cost of materials, labour, usage charges of machinerycomplete as per specifications and as per directions of the Engineer-in-Charge. .[I.No-11.5.1 /Page77 of PWD SR 2023-24] Volume-2 | Sqm | 4478.0 | 4478.0 | 10.08 | False | None | None | False | None | False | 45138.24 | 0 | 3569266 | 129500 | None | AEEBDM023 | Providing and fixing aluminium work for doors, windows, ventilators
and partitions with extruded built up standard tubular sections/
appropriate sections and other sections of approved make conforming to
IS: 733 and IS:1285, fixing with dash fasteners of required dia and
size, including necessary filling up the gaps at junctions, i.e. at top,
bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed
mechanically wherever required including cleat angle, Aluminium snap
beading for glazing / paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the directions of Engineer-incharge.(Glazing, paneling and dash fasteners to be paid for separately)
:For Fixed Portion: Powder coated aluminium (minimum thickness of
powder coating 50 micron) including cost of materials, labour, usage
charges of machinery complete as per specifications. .[I.No-11.35.1.2 /Page87 of PWD SR 2023-24] Volume-2 | Kg | 489.0 | 489.0 | 60.0 | False | None | None | False | None | False | 29340.0 | 0 | 3569267 | 129500 | None | AEEBDM024 | Providing & fixing glass panes with putty and glazing clips in steel
doors, windows, clerestory windows, all complete with : 4.0 mm thick
glass panes including cost of materials, labour, usage charges of machinerycomplete as per specifications and as per directions of the Engineer-in-Charge. .[I.No-11.30.1 /Page85 of PWD SR 2023-24] Volume-2 | Sqm | 912.0 | 912.0 | 4.5 | False | None | None | False | None | False | 4104.0 | 0 | 3569268 | 129500 | None | AEEBDM025 | SUB ESTIMATE FOR TOILET BLOCKS Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth .[I.No-1.15.1/Page8 of PWD SR 2023-24] Volume-1 | Cum | 363.0 | 363.0 | 30.09 | False | None | None | False | None | False | 10922.67 | 0 | 3569269 | 129500 | None | AEEBDM026 | Providing and laying in position Cement Concrete for levelling course forall works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges ofmachinery, curing, and all the other appurtenances required to complete thework as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates.[I.No-2.1.3/Page15 of PWD SR 2023-24] Volume-1 | Cum | 5989.0 | 5989.0 | 8.34 | False | None | None | False | None | False | 49948.26 | 0 | 3569270 | 129500 | None | AEEBDM027 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticizers laid in finishedlayers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plinth concrete[I.No-2.2.5/Page15 of PWD SR 2023-24] Volume-1 | Cum | 9748.5 | 9748.5 | 1.76 | False | None | None | False | None | False | 17157.36 | 0 | 3569271 | 129500 | None | AEEBDM028 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregatesas per relevant IS Codes machine mixed with super plasticizers laid in finishedlayers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Lintel and pit cover [I.No-2.2.5/Page15 of PWD SR 2023-24] Volume-1 | Cum | 10398.4 | 10398.4 | 1.2 | False | None | None | False | None | False | 12478.08 | 0 | 3569272 | 129500 | None | AEEBDM029 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing andtechnical specification Buildings Plinth beem and lintel [I.No-2.11a/Page 18 of PWD SR 2023-24] Volume-1 | Kg | 89.45 | 89.45 | 236.8 | False | None | None | False | None | False | 21181.76 | 0 | 3569273 | 129500 | None | AEEBDM030 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) [I.No-5.4/Page 9 of PWD SR 2023-24] Volume-2 | Cum | 6389.0 | 6389.0 | 19.39 | False | None | None | False | None | False | 123882.71 | 0 | 3569274 | 129500 | None | AEEBDM031 | Filling approved earth (excluding rock) in trenches,
plinth, sides of foundations and other similar works etc.
in layers not exceeding 20cm in depth, consolidating
each deposited layer by ramming and watering, lead
up to 50 m and lift upto 1.5 m. [I.No-1.11/Page 35 of PWD SR 2023-24] Volume1 | Cum | 433.0 | 433.0 | 27.05 | False | None | None | False | None | False | 11712.65 | 0 | 3569275 | 129500 | None | AEEBDM032 | Providing and constructing load bearing wall with Solid Concrete blocksof size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. [I.No-6.32/Page17 of PWD SR 2023-24] Volume-2 | Cum | 1310.0 | 1310.0 | 15.12 | False | None | None | False | None | False | 19807.2 | 0 | 3569276 | 129500 | None | AEEBDM033 | Providing and constructing load bearing wall with Solid Concrete blocks
of size 400x100x200mm having block density more than 1800kg/m3
and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005
including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. [I.No-6.34/Page17 of PWD SR 2023-24] Volume-2 | Cum | 1104.0 | 1104.0 | 22.11 | False | None | None | False | None | False | 24409.44 | 0 | 3569277 | 129500 | None | AEEBDM034 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) tobrick/stone masonry including rounding off corners wherever requiredsmooth rendering, providing and removing scaffolding, including cost ofmaterials, labour, curing complete as per specifications and as per directions
of Engineer-in-charge [I.No-8.3.1/Page41 of PWD SR 2023-24] Volume-2 | Sqm | 354.0 | 354.0 | 237.29 | False | None | None | False | None | False | 84000.66 | 0 | 3569278 | 129500 | None | AEEBDM035 | Providing White washing with lime to give an even shade :New work (three
coats) with lime of approved quality, including cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge. [I.No-8.21/Page44 of PWD SR 2023-24] Volume-2 | Sqm | 26.0 | 26.0 | 237.29 | False | None | None | False | None | False | 6169.54 | 0 | 3569279 | 129500 | None | AEEBDM036 | Finishing with Deluxe Multi surface paint system for interiors and exteriors
using Primer as per manufacturers specifications: Two coats applied on
walls @ 1.25 L/10 m² over and including one coat of Special primer applied
@ 0.75 L/10 m² with paint of approved quality to give an even shade, after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree
angle with 10 years life) [I.No-8.33.1/Page46 of PWD SR 2023-24] Volume-2 | Sqm | 158.0 | 158.0 | 237.29 | False | None | None | False | None | False | 37491.82 | 0 | 3569280 | 129500 | None | AEEBDM037 | Providing and laying vitrified floor tiles with thickness 9-10 mm in
different sizes with water absorption less than 0.08% and conforming to
IS: 15622, of approved make, in all colours and shades, laid on 20mm thickcement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cementslurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm [I.No-9.12.2/Page60 of PWD SR 2023-24] Volume-2 | Sqm | 1145.0 | 1145.0 | 89.03 | False | None | None | False | None | False | 101939.35 | 0 | 3569281 | 129500 | None | AEEBDM038 | Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flushbend, overflow arrangement with specials of standard make and mosquitoproof coupling of approved municipal design complete, includingpainting of fittings and brackets, cutting and making good the walls andfloors wherever required : W.C. pan with ISI marked white solid plastic seat and lid [I.No-14.3.1/Page131 of PWD SR 2023-24] Volume-2 | Each | 5977.0 | 5977.0 | 4.0 | False | None | None | False | None | False | 23908.0 | 0 | 3569282 | 129500 | None | AEEBDM039 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps [I.No-14.7.1/Page132 of PWD SR 2023-24] Volume-2 | Each | 3082.0 | 3082.0 | 3.0 | False | None | None | False | None | False | 9246.0 | 0 | 3569283 | 129500 | None | AEEBDM040 | Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain
with rubber plug, 40 mm C.P. brass waste complete, including painting
the fittings and brackets, cutting and making good the walls wherever
required: White glazed fire clay kitchen sink of size 600x450x 250 mm [I.No-14.9.1/Page133 of PWD SR 2023-24] Volume-2 | Each | 2981.0 | 2981.0 | 1.0 | False | None | None | False | None | False | 2981.0 | 0 | 3569284 | 129500 | None | AEEBDM041 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and fixturescomplete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests [I.No-14.1.1/Page131 of PWD SR 2023-24] Volume-2 | Each | 4884.0 | 4884.0 | 2.0 | False | None | None | False | None | False | 9768.0 | 0 | 3569285 | 129500 | None | AEEBDM042 | Providing and fixing granite stone slab with table rubbed, edges roundedand polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embeddingthe stone in the chase with epoxy grout or with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size)as per direction of Engineer-in- charge and finished smooth. [I.No-10.8/Page70 of PWD SR 2023-24] Volume-2 | Sqm | 2789.0 | 2789.0 | 2.4 | False | None | None | False | None | False | 6693.6 | 0 | 3569286 | 129500 | None | AEEBDM043 | Providing flooring with 25mm thick polished Cuddapah slabs using cementmortar 1:6, 25mm thick over existing cement concrete bed or top of rooflaid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing,polishing complete as per specifications. [I.No-9.36/Page64 of PWD SR 2023-24] Volume-2 | Sqm | 1650.0 | 1650.0 | 2.78 | False | None | None | False | None | False | 4587.0 | 0 | 3569287 | 129500 | None | AEEBDM044 | Providing and fixing 600x450 mm beveled edge mirror of superior glass
(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. [I.No-14.31/Page136 of PWD SR 2023-24] Volume-2 | Each | 1220.0 | 1220.0 | 3.0 | False | None | None | False | None | False | 3660.0 | 0 | 3569288 | 129500 | None | AEEBDM045 | Providing and fixing PTMT towel rail complete with brackets fixed to
wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. [I.No-14.40.1/Page137 of PWD SR 2023-24] Volume-2 | Each | 478.0 | 478.0 | 6.0 | False | None | None | False | None | False | 2868.0 | 0 | 3569289 | 129500 | None | AEEBDM046 | Providing & fixing corrugated G.S. sheet roofing including vertical /
curved surface fixed with polymer coated J or L hooks, bolts and nuts 8
mm diameter with bitumen and G.I. limpet washers or with G.I. limpet
washers filled with white lead, including a coat of approved steel primerand two coats of approved paint on overlapping of sheets complete asper design drawings (up to any pitch in horizontal/ vertical or curvedsurfaces), excluding the cost of purlins, rafters and trusses and includingcutting to size and shape wherever required as per the direction ofEngineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m² . [I.No-7.1.1/Page21 of PWD SR 2023-24] Volume-2 | Sqm | 879.0 | 879.0 | 69.2 | False | None | None | False | None | False | 60826.8 | 0 | 3569290 | 129500 | None | AEEBDM047 | Providing and fixing factory made uPVC door frame made of uPVC extrudedsections having an overall dimension as below (tolerance 1mm), with wallthickness 2.0 mm (0.2 mm), corners of the door frame to be Jointed withgalvanized brackets and stainless steel screws, joints mitred and Plasticwelded. The hinge side vertical of the frames reinforced by galvanized M.S.tube of size 19 19 mm and 1mm (0.1 mm) wall thickness and 3 nos.stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge 48x40 mm PVC Extruded section [I.No12.83.1/Page108 of PWD SR 2023-24] Volume2 | Mtr | 198.0 | 198.0 | 48.93 | False | None | None | False | None | False | 9688.14 | 0 | 3569291 | 129500 | None | AEEBDM048 | Providing& fixing of Openable door made out of multi chambered
UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium
Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free
with gaskets grey colour having isolated drainage and reinforced with
Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made [I.No-12.92/Page111 of PWD SR 2023-24] Volume-2 | Sqm | 6245.0 | 6245.0 | 19.74 | False | None | None | False | None | False | 123276.3 | 0 | 3569292 | 129500 | None | AEEBDM049 | Providing& fixing of Openable window made out of multi chambered
UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium
Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 75mm and GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 5mm plain float glass, Standard hardware with friction hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm.Maximumpossible size 900mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) [I.No-12.91/Page111 of PWD SR 2023-24] Volume-2 | Sqm | 6062.0 | 6062.0 | 4.73 | False | None | None | False | None | False | 28673.26 | 0 | 3569293 | 129500 | None | AEEBDM050 | Providing and fixing Structural Steel work in single section, fixed
with or without connecting plate, including cutting, hoisting, fixing in
position and applying a priming coat of approved steel primer all completeincluding cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. [I.No11.1/Page77 of PWD SR 2023-24] Volume-2 | Kg | 106.0 | 106.0 | 337.84 | False | None | None | False | None | False | 35811.04 | 0 |
|