1722419544000 | 1 | None | None | Buildings | Construction of Meeting Hall in Second Floor of Administrative Office Building with Staircase and Providing Improvements to 1000 MT. Godown Building along with Painting Main Market Yard of Koppa APMC Approved under 2022-23 Annual Action Plan | 3747481.22 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3658515 | 133483 | None | K001 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils to any depth, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse including cost of labour, tools & other appurtenaces required to complete the work. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 191.58 | 191.58 | 37.89 | False | None | None | False | None | False | 7258.9662 | 0 | 3658516 | 133483 | None | K002 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 5362.18 | 5362.18 | 4.99 | False | None | None | False | None | False | 26757.2782 | 0 | 3658517 | 133483 | None | K003 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 5958.84 | 5958.84 | 7.0 | False | None | None | False | None | False | 41711.88 | 0 | 3658518 | 133483 | None | K004 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 6596.73 | 6596.73 | 6.13 | False | None | None | False | None | False | 40437.9549 | 0 | 3658519 | 133483 | None | K005 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 9092.79 | 9092.79 | 1.71 | False | None | None | False | None | False | 15548.6709 | 0 | 3658520 | 133483 | None | K006 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 9183.79 | 9183.79 | 0.96 | False | None | None | False | None | False | 8816.4384 | 0 | 3658521 | 133483 | None | K007 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 9881.09 | 9881.09 | 2.64 | False | None | None | False | None | False | 26086.0776 | 0 | 3658522 | 133483 | None | K008 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formworkto be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 10694.86 | 10694.86 | 1.13 | False | None | None | False | None | False | 12085.1918 | 0 | 3658523 | 133483 | None | K009 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formworkto be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 10801.86 | 10801.86 | 1.13 | False | None | None | False | None | False | 12206.1018 | 0 | 3658524 | 133483 | None | K010 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formworkto be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 10908.76 | 10908.76 | 4.78 | False | None | None | False | None | False | 52143.8728 | 0 | 3658525 | 133483 | None | K011 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formworkto be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lift etc.complete as directed by the Engineer-In-Charge of the work | Cum | 9458.46 | 9458.46 | 2.62 | False | None | None | False | None | False | 24781.1652 | 0 | 3658526 | 133483 | None | K012 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formworkto be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 9553.46 | 9553.46 | 4.38 | False | None | None | False | None | False | 41844.1548 | 0 | 3658527 | 133483 | None | K013 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with all lead and lift etc.complete as directed by the Engineer-In-Charge of the work | Cum | 10908.86 | 10908.86 | 7.23 | False | None | None | False | None | False | 78871.0578 | 0 | 3658528 | 133483 | None | K014 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 9332.36 | 9332.36 | 0.7 | False | None | None | False | None | False | 6532.652 | 0 | 3658529 | 133483 | None | K015 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges (The laps and wastages shall not be measured separately) etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Kg | 98.88 | 98.88 | 1448.75 | False | None | None | False | None | False | 143252.4 | 0 | 3658530 | 133483 | None | K016 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges (The laps and wastages shall not be measured separately) etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Kg | 99.88 | 99.88 | 808.75 | False | None | None | False | None | False | 80777.95 | 0 | 3658531 | 133483 | None | K017 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges (The laps and wastages shall not be measured separately) etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Kg | 100.88 | 100.88 | 1609.0 | False | None | None | False | None | False | 162315.92 | 0 | 3658532 | 133483 | None | K018 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Kg | 515.0 | 515.0 | 183.6 | False | None | None | False | None | False | 94554.0 | 0 | 3658533 | 133483 | None | K019 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Kg | 520.0 | 520.0 | 183.6 | False | None | None | False | None | False | 95472.0 | 0 | 3658534 | 133483 | None | K020 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Kg | 525.0 | 525.0 | 153.0 | False | None | None | False | None | False | 80325.0 | 0 | 3658535 | 133483 | None | K021 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 1955.97 | 1955.97 | 24.3 | False | None | None | False | None | False | 47530.071 | 0 | 3658536 | 133483 | None | K022 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 6896.88 | 6896.88 | 5.32 | False | None | None | False | None | False | 36691.4016 | 0 | 3658537 | 133483 | None | K023 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 7034.88 | 7034.88 | 36.37 | False | None | None | False | None | False | 255858.5856 | 0 | 3658538 | 133483 | None | K024 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 210.12 | 210.12 | 37.89 | False | None | None | False | None | False | 7961.4468 | 0 | 3658539 | 133483 | None | K025 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 1975.97 | 1975.97 | 16.6 | False | None | None | False | None | False | 32801.102 | 0 | 3658540 | 133483 | None | K026 | Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all The cleaning shall consist following operations:- etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 59.71 | 59.71 | 93.42 | False | None | None | False | None | False | 5578.1082 | 0 | 3658541 | 133483 | None | K027 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/ Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 775.35 | 775.35 | 93.42 | False | None | None | False | None | False | 72433.197 | 0 | 3658542 | 133483 | None | K028 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Kg | 53.53 | 53.53 | 411.04 | False | None | None | False | None | False | 22002.9712 | 0 | 3658543 | 133483 | None | K029 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 79156.32 | 79156.32 | 0.14 | False | None | None | False | None | False | 11081.8848 | 0 | 3658544 | 133483 | None | K030 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges (excluding cost of fixtures ) etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Cum | 4229.78 | 4229.78 | 2.52 | False | None | None | False | None | False | 10659.0456 | 0 | 3658545 | 133483 | None | K031 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Kg | 150.29 | 150.29 | 330.75 | False | None | None | False | None | False | 49708.4175 | 0 | 3658546 | 133483 | None | K032 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Kg | 407.88 | 407.88 | 351.12 | False | None | None | False | None | False | 143214.8256 | 0 | 3658547 | 133483 | None | K033 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Kg | 411.88 | 411.88 | 351.12 | False | None | None | False | None | False | 144619.3056 | 0 | 3658548 | 133483 | None | K034 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Kg | 415.88 | 415.88 | 657.83 | False | None | None | False | None | False | 273578.3404 | 0 | 3658549 | 133483 | None | K035 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 842.03 | 842.03 | 1.52 | False | None | None | False | None | False | 1279.8856 | 0 | 3658550 | 133483 | None | K036 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 962.48 | 962.48 | 1.52 | False | None | None | False | None | False | 1462.9696 | 0 | 3658551 | 133483 | None | K037 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes including cost of materials, labour, usage charges of machinery etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 734.39 | 734.39 | 10.03 | False | None | None | False | None | False | 7365.9317 | 0 | 3658552 | 133483 | None | K038 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes including cost of materials, labour, usage charges of machinery etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 741.39 | 741.39 | 10.03 | False | None | None | False | None | False | 7436.1417 | 0 | 3658553 | 133483 | None | K039 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes including cost of materials, labour, usage charges of machinery etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 749.39 | 749.39 | 15.75 | False | None | None | False | None | False | 11802.8925 | 0 | 3658554 | 133483 | None | K040 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments Size of Tile 600x600 mm etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 1153.94 | 1153.94 | 133.44 | False | None | None | False | None | False | 153981.7536 | 0 | 3658555 | 133483 | None | K041 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 812.19 | 812.19 | 37.19 | False | None | None | False | None | False | 30205.3461 | 0 | 3658556 | 133483 | None | K042 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 208.06 | 208.06 | 95.47 | False | None | None | False | None | False | 19863.4882 | 0 | 3658557 | 133483 | None | K043 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 210.06 | 210.06 | 122.06 | False | None | None | False | None | False | 25639.9236 | 0 | 3658558 | 133483 | None | K044 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 241.9 | 241.9 | 237.57 | False | None | None | False | None | False | 57468.183 | 0 | 3658559 | 133483 | None | K045 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 328.39 | 328.39 | 210.13 | False | None | None | False | None | False | 69004.5907 | 0 | 3658560 | 133483 | None | K046 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour with primer. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 109.18 | 109.18 | 74.27 | False | None | None | False | None | False | 8108.7986 | 0 | 3658561 | 133483 | None | K047 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour with primer. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 110.18 | 110.18 | 54.1 | False | None | None | False | None | False | 5960.738 | 0 | 3658562 | 133483 | None | K048 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour with primer. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 111.18 | 111.18 | 47.68 | False | None | None | False | None | False | 5301.0624 | 0 | 3658563 | 133483 | None | K049 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 140.08 | 140.08 | 540.39 | False | None | None | False | None | False | 75697.8312 | 0 | 3658564 | 133483 | None | K050 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 141.08 | 141.08 | 445.89 | False | None | None | False | None | False | 62906.1612 | 0 | 3658565 | 133483 | None | K051 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 143.08 | 143.08 | 237.57 | False | None | None | False | None | False | 33991.5156 | 0 | 3658566 | 133483 | None | K052 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 108.15 | 108.15 | 903.93 | False | None | None | False | None | False | 97760.0295 | 0 | 3658567 | 133483 | None | K053 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 109.15 | 109.15 | 260.87 | False | None | None | False | None | False | 28473.9605 | 0 | 3658568 | 133483 | None | K054 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 110.15 | 110.15 | 210.13 | False | None | None | False | None | False | 23145.8195 | 0 | 3658569 | 133483 | None | K055 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 133.9 | 133.9 | 102.24 | False | None | None | False | None | False | 13689.936 | 0 | 3658570 | 133483 | None | K056 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 134.9 | 134.9 | 48.16 | False | None | None | False | None | False | 6496.784 | 0 | 3658571 | 133483 | None | K057 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 136.9 | 136.9 | 46.24 | False | None | None | False | None | False | 6330.256 | 0 | 3658572 | 133483 | None | K058 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Kg | 112.27 | 112.27 | 1025.82 | False | None | None | False | None | False | 115168.8114 | 0 | 3658573 | 133483 | None | K059 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Kg | 114.27 | 114.27 | 2503.25 | False | None | None | False | None | False | 286046.3775 | 0 | 3658574 | 133483 | None | K060 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 572.68 | 572.68 | 43.05 | False | None | None | False | None | False | 24653.874 | 0 | 3658575 | 133483 | None | K061 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 583.68 | 583.68 | 137.48 | False | None | None | False | None | False | 80244.3264 | 0 | 3658576 | 133483 | None | K062 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws Ridges plain (500 - 600mm) etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Mtr | 371.83 | 371.83 | 62.28 | False | None | None | False | None | False | 23157.5724 | 0 | 3658577 | 133483 | None | K063 | KSRB 4-8 : Providing two legged scaffolding for brick masonry work using 10-15 cms. dia best quality Casurina poles of 4m over all length (3m +0.5m projection + 0.5m In to the ground) the distance between two rows being 1.25m and spacing of post being 2m in both rows with 2 horizontal posts with 0.5 mm overlap on either side and braces at 2 m c to c including longitudinal and transveres middle braces to step up and providing platform with casurina poles, forms tied up using coir rope for non modular brick work etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 120.0 | 120.0 | 720.52 | False | None | None | False | None | False | 86462.4 | 0 | 3658578 | 133483 | None | K064 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 5258.15 | 5258.15 | 2.0 | False | None | None | False | None | False | 10516.3 | 0 | 3658579 | 133483 | None | K065 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 342.78 | 342.78 | 6.0 | False | None | None | False | None | False | 2056.68 | 0 | 3658580 | 133483 | None | K066 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 403.52 | 403.52 | 2.0 | False | None | None | False | None | False | 807.04 | 0 | 3658581 | 133483 | None | K067 | Providing and fixing 100 mm sand cast Iron grating for gully trap. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 215.15 | 215.15 | 4.0 | False | None | None | False | None | False | 860.6 | 0 | 3658582 | 133483 | None | K068 | Providing and fixing white vitreous china wash basin including making all connections but including the cost of fittings : Flat back wash basin of size 630x450 mm etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 1123.07 | 1123.07 | 2.0 | False | None | None | False | None | False | 2246.14 | 0 | 3658583 | 133483 | None | K069 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 399.4 | 399.4 | 2.0 | False | None | None | False | None | False | 798.8 | 0 | 3658584 | 133483 | None | K070 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 1020.13 | 1020.13 | 2.0 | False | None | None | False | None | False | 2040.26 | 0 | 3658585 | 133483 | None | K071 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Mtr | 413.82 | 413.82 | 25.0 | False | None | None | False | None | False | 10345.5 | 0 | 3658586 | 133483 | None | K072 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) Medium Duty GI pipe of 25mm dia etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Mtr | 277.95 | 277.95 | 50.0 | False | None | None | False | None | False | 13897.5 | 0 | 3658587 | 133483 | None | K073 | KSRB 13-11.: Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 :1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing (For 1000 litre capacity) Specification No.KBS 13.22 etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 6854.0 | 6854.0 | 1.0 | False | None | None | False | None | False | 6854.0 | 0 | 3658588 | 133483 | None | K074 | KSRB 4-8 : Providing two legged scaffolding for brick masonry work using 10-15 cms. dia best quality Casurina poles of 4m over all length (3m +0.5m projection + 0.5m In to the ground) the distance between two rows being 1.25m and spacing of post being 2m in both rows with 2 horizontal posts with 0.5 mm overlap on either side and braces at 2 m c to c including longitudinal and transveres middle braces to step up and providing platform with casurina poles, forms tied up using coir rope for non modular brick work etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Sqm | 120.0 | 120.0 | 561.13 | False | None | None | False | None | False | 67335.6 | 0 | 3658589 | 133483 | None | K075 | Open Conduit System Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick. confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Mtr | 80.0 | 80.0 | 30.0 | False | None | None | False | None | False | 2400.0 | 0 | 3658590 | 133483 | None | K076 | Supplying heavy gauge PVC Conduit Pipe19/20mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Mtr | 75.0 | 75.0 | 10.0 | False | None | None | False | None | False | 750.0 | 0 | 3658591 | 133483 | None | K077 | Supplying heavy gauge PVC Conduit Pipe 25mm dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Mtr | 80.0 | 80.0 | 30.0 | False | None | None | False | None | False | 2400.0 | 0 | 3658592 | 133483 | None | K078 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make 200x200x65mm etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Each | 335.0 | 335.0 | 3.0 | False | None | None | False | None | False | 1005.0 | 0 | 3658593 | 133483 | None | K079 | Supplying and fixing PVC/metal conduit Deep junction box 25mm deep junction box etc.complete as per technical specification with all lead and lift and as directed by the Engineer In Charge of the work. | No | 51.0 | 51.0 | 8.0 | False | None | None | False | None | False | 408.0 | 0 | 3658594 | 133483 | None | K080 | Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase AND Neutral) and 1x0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch etc, complete as per technical specification with all lead and lift and as directed by the Engineer In Charge of the work. | Nos | 251.0 | 251.0 | 3.0 | False | None | None | False | None | False | 753.0 | 0 | 3658595 | 133483 | None | K081 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3M. upto 6M from tapping point to out let via switch etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Nos | 361.0 | 361.0 | 5.0 | False | None | None | False | None | False | 1805.0 | 0 | 3658596 | 133483 | None | K082 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic Sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr. upto 10M from tapping point to out let via switch etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Nos | 542.0 | 542.0 | 8.0 | False | None | None | False | None | False | 4336.0 | 0 | 3658597 | 133483 | None | K083 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 sqmmetc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Mtr | 26.0 | 26.0 | 39.0 | False | None | None | False | None | False | 1014.0 | 0 | 3658598 | 133483 | None | K084 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 sqmm etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Mtr | 40.0 | 40.0 | 80.0 | False | None | None | False | None | False | 3200.0 | 0 | 3658599 | 133483 | None | K085 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 212.0 | 212.0 | 4.0 | False | None | None | False | None | False | 848.0 | 0 | 3658600 | 133483 | None | K086 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall10-12Way etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 325.0 | 325.0 | 2.0 | False | None | None | False | None | False | 650.0 | 0 | 3658601 | 133483 | None | K087 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.6 Module etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 244.0 | 244.0 | 1.0 | False | None | None | False | None | False | 244.0 | 0 | 3658602 | 133483 | None | K088 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.12 Module etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 363.0 | 363.0 | 2.0 | False | None | None | False | None | False | 726.0 | 0 | 3658603 | 133483 | None | K089 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps one way. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 88.0 | 88.0 | 12.0 | False | None | None | False | None | False | 1056.0 | 0 | 3658604 | 133483 | None | K090 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket.etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 162.0 | 162.0 | 10.0 | False | None | None | False | None | False | 1620.0 | 0 | 3658605 | 133483 | None | K091 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator.etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 313.0 | 313.0 | 8.0 | False | None | None | False | None | False | 2504.0 | 0 | 3658606 | 133483 | None | K092 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps SP. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 523.0 | 523.0 | 2.0 | False | None | None | False | None | False | 1046.0 | 0 | 3658607 | 133483 | None | K093 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door 8 Way SP & N etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 1695.0 | 1695.0 | 2.0 | False | None | None | False | None | False | 3390.0 | 0 | 3658608 | 133483 | None | K094 | Supplying, fixing and wiring Earth Leakage Miniature CircuitBreaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 16-25 A 2 pole etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 2536.0 | 2536.0 | 1.0 | False | None | None | False | None | False | 2536.0 | 0 | 3658609 | 133483 | None | K095 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 16Amps etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Each | 125.0 | 125.0 | 1.0 | False | None | None | False | None | False | 125.0 | 0 | 3658610 | 133483 | None | K096 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Each | 1242.0 | 1242.0 | 1.0 | False | None | None | False | None | False | 1242.0 | 0 | 3658611 | 133483 | None | K097 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300mmx300mmx214mm etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Each | 4054.0 | 4054.0 | 1.0 | False | None | None | False | None | False | 4054.0 | 0 | 3658612 | 133483 | None | K098 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value greater than or equal to 4.2 CMM / Watt, Three Blades of blade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation,Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 degC over and ambient of 40 0C by resistance method at 245Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty48" Sweep 5 Star (1200mm) etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 2949.0 | 2949.0 | 8.0 | False | None | None | False | None | False | 23592.0 | 0 | 3658613 | 133483 | None | K099 | Supplying of feet - PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x 4 20/22 w (etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 740.0 | 740.0 | 6.0 | False | None | None | False | None | False | 4440.0 | 0 | 3658614 | 133483 | None | K100 | Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulatedwires, required Nos of round blocks and clamps. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 119.0 | 119.0 | 12.0 | False | None | None | False | None | False | 1428.0 | 0 | 3658615 | 133483 | None | K101 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and
wired. etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 281.0 | 281.0 | 10.0 | False | None | None | False | None | False | 2810.0 | 0 | 3658616 | 133483 | None | K102 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 35 kA etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Each | 18566.0 | 18566.0 | 1.0 | False | None | None | False | None | False | 18566.0 | 0 | 3658617 | 133483 | None | K103 | Supplying of feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4 inches - 36/40 W etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Each | 1197.0 | 1197.0 | 3.0 | False | None | None | False | None | False | 3591.0 | 0 | 3658618 | 133483 | None | K104 | Grounding Material-Rod Earthing Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specified) etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | No | 2253.0 | 2253.0 | 1.0 | False | None | None | False | None | False | 2253.0 | 0 | 3658619 | 133483 | None | K105 | Bentonite clay slurry for earthing in 50 Kg Bag) etc., complete as per technical specification with all lead and lift and as directed by the Engineer-In-Charge of the work. | Bag | 326.0 | 326.0 | 1.0 | False | None | None | False | None | False | 326.0 | 0 |
|