tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1722347166000 | 0 | None | None | Buildings | Construction of 1 Class Rooms to Government Pre- University College (High School Division) at Sirwar / manvi Taluka of Raichur District. | 1557374.54 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3652004 | 133175 | None | 001 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 107.1 | 107.1 | 51.77 | False | None | None | False | None | False | 5544.567 | 0 | 3652005 | 133175 | None | 002 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 7.23 | False | None | None | False | None | False | 42998.256 | 0 | 3652006 | 133175 | None | 003 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Footing | Cum | 6961.5 | 6961.5 | 5.83 | False | None | None | False | None | False | 40585.545 | 0 | 3652007 | 133175 | None | 004 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Column | Cum | 6961.5 | 6961.5 | 3.75 | False | None | None | False | None | False | 26105.625 | 0 | 3652008 | 133175 | None | 005 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Plinth Beam | Cum | 6961.5 | 6961.5 | 2.8 | False | None | None | False | None | False | 19492.2 | 0 | 3652009 | 133175 | None | 006 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Lintel | Cum | 6961.5 | 6961.5 | 1.01 | False | None | None | False | None | False | 7031.115 | 0 | 3652010 | 133175 | None | 007 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Chajja | Cum | 6961.5 | 6961.5 | 0.16 | False | None | None | False | None | False | 1113.84 | 0 | 3652011 | 133175 | None | 008 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Roof Beam | Cum | 6961.5 | 6961.5 | 4.19 | False | None | None | False | None | False | 29168.685 | 0 | 3652012 | 133175 | None | 009 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Slab | Cum | 6961.5 | 6961.5 | 9.25 | False | None | None | False | None | False | 64393.875 | 0 | 3652013 | 133175 | None | 010 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Centering & Shuttering Charges For Footing | Cum | 208.84 | 208.84 | 5.83 | False | None | None | False | None | False | 1217.5372 | 0 | 3652014 | 133175 | None | 011 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Centering & Shuttering Charges For Column | Cum | 4873.05 | 4873.05 | 3.75 | False | None | None | False | None | False | 18273.9375 | 0 | 3652015 | 133175 | None | 012 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Centering & Shuttering Charges For Plinth Beam | Cum | 3480.75 | 3480.75 | 2.8 | False | None | None | False | None | False | 9746.1 | 0 | 3652016 | 133175 | None | 013 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Centering & Shuttering Charges For Lintel Beam | Cum | 4176.9 | 4176.9 | 1.01 | False | None | None | False | None | False | 4218.669 | 0 | 3652017 | 133175 | None | 014 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Centering & Shuttering Charges For Chajja | Cum | 3132.67 | 3132.67 | 0.16 | False | None | None | False | None | False | 501.2272 | 0 | 3652018 | 133175 | None | 015 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Centering & Shuttering Charges For Roof Beam | Cum | 4176.9 | 4176.9 | 4.19 | False | None | None | False | None | False | 17501.211 | 0 | 3652019 | 133175 | None | 016 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Centering & Shuttering Charges For Slab | Cum | 3480.75 | 3480.75 | 9.25 | False | None | None | False | None | False | 32196.9375 | 0 | 3652020 | 133175 | None | 017 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 19.54 | False | None | None | False | None | False | 115120.887 | 0 | 3652021 | 133175 | None | 018 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 14.84 | False | None | None | False | None | False | 99553.398 | 0 | 3652022 | 133175 | None | 019 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | MT | 93929.85 | 93929.85 | 2.6995 | False | None | None | False | None | False | 253563.630075 | 0 | 3652023 | 133175 | None | 020 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 25.0 | False | None | None | False | None | False | 6982.5 | 0 | 3652024 | 133175 | None | 021 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 25.35 | False | None | None | False | None | False | 12616.695 | 0 | 3652025 | 133175 | None | 022 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 17.52 | False | None | None | False | None | False | 146597.724 | 0 | 3652026 | 133175 | None | 023 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 130412.1 | 130412.1 | 0.18 | False | None | None | False | None | False | 23474.178 | 0 | 3652027 | 133175 | None | 024 | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kgs | 176.4 | 176.4 | 141.75 | False | None | None | False | None | False | 25004.7 | 0 | 3652028 | 133175 | None | 025 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 52.5 | 52.5 | 15.19 | False | None | None | False | None | False | 797.475 | 0 | 3652029 | 133175 | None | 026 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 15.19 | False | None | None | False | None | False | 1834.1925 | 0 | 3652030 | 133175 | None | 027 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1066.8 | 1066.8 | 2.0 | False | None | None | False | None | False | 2133.6 | 0 | 3652031 | 133175 | None | 028 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer- in-Charge. | Kgs | 593.25 | 593.25 | 161.28 | False | None | None | False | None | False | 95679.36 | 0 | 3652032 | 133175 | None | 029 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 221.55 | 221.55 | 61.5 | False | None | None | False | None | False | 13625.325 | 0 | 3652033 | 133175 | None | 030 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 241.35 | False | None | None | False | None | False | 94017.8925 | 0 | 3652034 | 133175 | None | 031 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 5.8 | False | None | None | False | None | False | 37861.53 | 0 | 3652035 | 133175 | None | 032 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1717.8 | 1717.8 | 73.16 | False | None | None | False | None | False | 125674.248 | 0 | 3652036 | 133175 | None | 033 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 30 mm thick Both side teak. | Sqm | 4245.15 | 4245.15 | 5.04 | False | None | None | False | None | False | 21395.556 | 0 | 3652037 | 133175 | None | 034 | roviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). | Sqm | 5659.5 | 5659.5 | 5.4 | False | None | None | False | None | False | 30561.3 | 0 | 3652038 | 133175 | None | 035 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). | Sqm | 6004.95 | 6004.95 | 1.35 | False | None | None | False | None | False | 8106.6825 | 0 | 3652039 | 133175 | None | 036 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Nos | 126.0 | 126.0 | 2.0 | False | None | None | False | None | False | 252.0 | 0 | 3652040 | 133175 | None | 037 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 248.85 | 248.85 | 4.0 | False | None | None | False | None | False | 995.4 | 0 | 3652041 | 133175 | None | 038 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 136.5 | 136.5 | 4.0 | False | None | None | False | None | False | 546.0 | 0 | 3652042 | 133175 | None | 039 | Providing M.S. Piano hinges ISI marked IS : 3818 finished with nickel plating and fixing with necessary screws etc., complete. | Nos | 312.9 | 312.9 | 6.0 | False | None | None | False | None | False | 1877.4 | 0 | 3652043 | 133175 | None | 040 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 139.65 | False | None | None | False | None | False | 14663.25 | 0 | 3652044 | 133175 | None | 041 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 194.0 | False | None | None | False | None | False | 27906.9 | 0 | 3652045 | 133175 | None | 042 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 109.54 | False | None | None | False | None | False | 10236.513 | 0 | 3652046 | 133175 | None | 043 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete. | Sqm | 498.75 | 498.75 | 5.76 | False | None | None | False | None | False | 2872.8 | 0 | 3652047 | 133175 | None | 044 | polyurethane based single Component for New surface, Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa- terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa- terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 855.75 | 855.75 | 74.01 | False | None | None | False | None | False | 63334.0575 | 0 |
| 1722347166000 | 0 | None | None | Buildings | FOR ELECTRICAL WORK | 79016.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3652048 | 133176 | None | 001 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick
confirming to IS 2509 with suitable size bends, metal/PVC Junction
boxes, adhesive paste etc., and running before concreting the slab. The
conduit should be tied to the reinforcement rods by using binding
wires and unused ways of junction boxes and pipe ends should be
covered using PVC end enclosures, run with 18SWG GI fish wire
wherever necessary | Mtr | 66.0 | 66.0 | 90.0 | False | None | None | False | None | False | 5940.0 | 0 | 3652049 | 133176 | None | 002 | Supplying heavy gauge PVC Conduit Pipe . dia . mm thick
with suitable size bends, metal junction boxes adhesive paste etc., by
groove cutting in the wall and fixing by bracing U or J hooks and
cement plastering upto the wall surface and run with 18 SWG GI fish
wire run throughout the conduit wherever necessary | Mtr | 79.0 | 79.0 | 90.0 | False | None | None | False | None | False | 7110.0 | 0 | 3652050 | 133176 | None | 003 | Supplying and fixing PVC/metal conduit Deep junction box | Mtr | 56.0 | 56.0 | 6.0 | False | None | None | False | None | False | 336.0 | 0 | 3652051 | 133176 | None | 004 | Supplying and flush mounting teak wooden box without front plank,
made of not less than 12 mm thick wood, after due groove cutting,
finishing with necessary cement plastering complete. | Each | 112.0 | 112.0 | 2.0 | False | None | None | False | None | False | 224.0 | 0 | 3652052 | 133176 | None | 005 | Supplying and Fixing Mrtal Fan Box with Round Hook. | Nos | 160.0 | 160.0 | 4.0 | False | None | None | False | None | False | 640.0 | 0 | 3652053 | 133176 | None | 006 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 10.0 | False | None | None | False | None | False | 2850.0 | 0 | 3652054 | 133176 | None | 007 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet Medium point above 3Mtr upto 6Mtr from tapping point to out let via
switch | Point | 394.0 | 394.0 | 10.0 | False | None | None | False | None | False | 3940.0 | 0 | 3652055 | 133176 | None | 008 | Supplying and wiring adopting loop system in existing PVC
Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) &
1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated
copper wire (confirming to IS-694: and latest amendments) with
a 6Amps flush type SP control switch shall be fixed on the existing
plastic sheet/ gang box, the other end of the wires shall be terminated
with sufficient loose length in a wood/PVC round block. complete for
each outlet Long point above 6Mtr upto 10Mtr from tapping point to out let via
switch | Point | 570.0 | 570.0 | 10.0 | False | None | None | False | None | False | 5700.0 | 0 | 3652056 | 133176 | None | 009 | Supplying and drawing Flexible Multicore Cable manufactured with
electrolytic grade flexible copper with low conductor confirming to
IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for
working voltage upto 1100 Volts as per IS-694:1990 3C x 1.5 mm2 | Mtr | 72.0 | 72.0 | 145.0 | False | None | None | False | None | False | 10440.0 | 0 | 3652057 | 133176 | None | 010 | Supplying and drawing Flexible Multicore Cable manufactured with
electrolytic grade flexible copper with low conductor confirming to
IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for
working voltage upto 1100 Volts as per IS-694:19904C x 1.5 mm2 | Mtr | 94.0 | 94.0 | 145.0 | False | None | None | False | None | False | 13630.0 | 0 | 3652058 | 133176 | None | 011 | Supplying 6A flush type socket and 6 A flush type SP switch either
surface/flush mounting in existing gang box or in 4mm thick plastic
sheet and fixing over a flush mounted wooden box and wiring using
necessary capacity wires as required as per IS 1293 and IS 3854 6A 2 Way | Each | 128.0 | 128.0 | 4.0 | False | None | None | False | None | False | 512.0 | 0 | 3652059 | 133176 | None | 012 | Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board6A Two Way Switch | Nos | 70.0 | 70.0 | 4.0 | False | None | None | False | None | False | 280.0 | 0 | 3652060 | 133176 | None | 013 | Supplying and fixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with required
nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. | Each | 137.0 | 137.0 | 10.0 | False | None | None | False | None | False | 1370.0 | 0 | 3652061 | 133176 | None | 014 | Supplying and fixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with required
nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. | Each | 175.0 | 175.0 | 10.0 | False | None | None | False | None | False | 1750.0 | 0 | 3652062 | 133176 | None | 015 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existing wooden or
metal box using N.F. screws | Sq CM | 0.41 | 0.41 | 2000.0 | False | None | None | False | None | False | 820.0 | 0 | 3652063 | 133176 | None | 016 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system | Each | 3031.0 | 3031.0 | 4.0 | False | None | None | False | None | False | 12124.0 | 0 | 3652064 | 133176 | None | 017 | Supplying & fixing retrofit type-PL- LED Lamp . W LED
linear source with CCT 6500 degree K, CRI 70%. efficacy 80
lumen per W, life 25000 burning hours and Compliance to IS
10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF
electronic driver integrated in the system, with PF 0.95, power loss
should 5% of lamp Wage., short circuit & open circuit protection to
be integrated in the circuit, THD less than 20%, Life as per LM 79.
The operating input voltage should be between 130 to275 V. Tested
by NABL/CPRI accredited laboratory with 2 years Warranty against
any manufacturing defect working under standard electrical condition 18-20 W | Each | 702.0 | 702.0 | 4.0 | False | None | None | False | None | False | 2808.0 | 0 | 3652065 | 133176 | None | 018 | Fixing all types and all capacities of fluorescent /false ceiling / spot
light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders
using 23/0.0076" twin twisted PVC insulated wires, required Nos of
round blocks and clamps On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 4.0 | False | None | None | False | None | False | 488.0 | 0 | 3652066 | 133176 | None | 019 | Fixing a ceiling /wall mounting fan of all capacities and all types,
with necessary clamps and 'S' hook made out of 15mm dia MS rod,
with 5 A. ceiling rose of approved quality with necessary length of
23/0.0076 inch PVC insulated twin twisted wire of approved quality,
mounted on a suitable size wooden board and wired. | Each | 315.0 | 315.0 | 4.0 | False | None | None | False | None | False | 1260.0 | 0 | 3652067 | 133176 | None | 020 | Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | Job | 3750.0 | 3750.0 | 1.0 | False | None | None | False | None | False | 3750.0 | 0 | 3652068 | 133176 | None | 021 | Supplying and fixing regular MCB distribution boards on wall/ wood board / flush mounting using required clamps, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase / 3 phase / single door with powdercoated painting. Made out of 14 SWG MS enclosure. | Each | 3044.0 | 3044.0 | 1.0 | False | None | None | False | None | False | 3044.0 | 0 |
| 1722347166000 | 0 | None | None | Buildings | Repairs to Government Pre- University College (High School Division) at Sirwar / Manvi Taluka of Raichur District. | 819800.57 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3652069 | 133177 | None | 001 | Providing and laying water proofing treatment to the Roof with PU based
single component elastomeric pure polyurethane based coating on New
terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa-
terproofing membrane that is highly elastic with elongation greater than
400% and tensile strength greater than 2MPa as per ASTM D412. The
waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve
final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy
primer @150 g/m 2 and protection with 120gsm Geo-textile over the wa-
terproofing membrane. The finished cost to include surface preparation,
making coving at Junction, Bore Packing, treatment of construction joints
completely as per specification. | Sqm | 857.85 | 857.85 | 241.2 | False | None | None | False | None | False | 206913.42 | 0 | 3652070 | 133177 | None | 002 | Providing and constructing load bearing wall with Solid Concrete blocks
of size 400x200x200mm having block density more than 1800kg/m3
and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005
including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. | Sqm | 1375.5 | 1375.5 | 91.14 | False | None | None | False | None | False | 125363.07 | 0 | 3652071 | 133177 | None | 003 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:
4 fine sand) to brick masonry including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 267.75 | 267.75 | 182.28 | False | None | None | False | None | False | 48805.47 | 0 | 3652072 | 133177 | None | 004 | Providing & fixing corrugated G.S. sheet roofing including vertical /
curved surface fixed with polymer coated J or L hooks, bolts and nuts 8
mm diameter with bitumen and G.I. limpet washers or with G.I. limpet
washers filled with white lead, including a coat of approved steel primer
and two coats of approved paint on overlapping of sheets complete as
per design drawings (up to any pitch in horizontal/ vertical or curved
surfaces), excluding the cost of purlins, rafters and trusses and including
cutting to size and shape wherever required as per the direction of
Engineer in charge.0.63 mm thick with zinc coating not less than 275 g/ m² | Sqm | 922.95 | 922.95 | 101.25 | False | None | None | False | None | False | 93448.6875 | 0 | 3652073 | 133177 | None | 005 | Providing and fixing Steel work in built up tubular (round, square or
rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer,
including welding and bolted with special shaped washers etc. complete.
Hot finished seamless type tubes including cost of materials, labour, usage
charges of machinery complete as per specifications and as per directions
of the Engineer-in-Charge. | Kgs | 154.35 | 154.35 | 1237.5 | False | None | None | False | None | False | 191008.125 | 0 | 3652074 | 133177 | None | 006 | Providing and fixing Structural Steel work in single section, fixed
with or without connecting plate, including cutting, hoisting, fixing in
position and applying a priming coat of approved steel primer all complete
including cost of materials, labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge | Sqm | 111.3 | 111.3 | 1386.0 | False | None | None | False | None | False | 154261.8 | 0 |
| 1722347166000 | 0 | None | None | Buildings | Construction of 1 Class Rooms to Government Pre-University College at Kavithal Village in Manvi Taluka of Raichur District. | 1557374.54 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3652075 | 133178 | None | 001 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 107.1 | 107.1 | 51.77 | False | None | None | False | None | False | 5544.567 | 0 | 3652076 | 133178 | None | 002 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 7.23 | False | None | None | False | None | False | 42998.256 | 0 | 3652077 | 133178 | None | 003 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Footing | Cum | 6961.5 | 6961.5 | 5.83 | False | None | None | False | None | False | 40585.545 | 0 | 3652078 | 133178 | None | 004 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Column | Cum | 6961.5 | 6961.5 | 3.75 | False | None | None | False | None | False | 26105.625 | 0 | 3652079 | 133178 | None | 005 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Plith Beam | Cum | 6961.5 | 6961.5 | 2.8 | False | None | None | False | None | False | 19492.2 | 0 | 3652080 | 133178 | None | 006 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Lintel | Cum | 6961.5 | 6961.5 | 1.01 | False | None | None | False | None | False | 7031.115 | 0 | 3652081 | 133178 | None | 007 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Chajja | Cum | 6961.5 | 6961.5 | 0.16 | False | None | None | False | None | False | 1113.84 | 0 | 3652082 | 133178 | None | 008 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Roof Beam | Cum | 6961.5 | 6961.5 | 4.19 | False | None | None | False | None | False | 29168.685 | 0 | 3652083 | 133178 | None | 009 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Slab | Cum | 6961.5 | 6961.5 | 9.25 | False | None | None | False | None | False | 64393.875 | 0 | 3652084 | 133178 | None | 010 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & Shuttering Charges For Footing | Cum | 208.84 | 208.84 | 5.83 | False | None | None | False | None | False | 1217.5372 | 0 | 3652085 | 133178 | None | 011 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & Shuttering Charges For Column | Cum | 4873.05 | 4873.05 | 3.75 | False | None | None | False | None | False | 18273.9375 | 0 | 3652086 | 133178 | None | 012 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & Shuttering Charges For Plith Beam | Cum | 3480.75 | 3480.75 | 2.8 | False | None | None | False | None | False | 9746.1 | 0 | 3652087 | 133178 | None | 013 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & Shuttering Charges For Lintel Beam | Cum | 4176.9 | 4176.9 | 1.01 | False | None | None | False | None | False | 4218.669 | 0 | 3652088 | 133178 | None | 014 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & Shuttering Charges For Chajja | Cum | 3132.67 | 3132.67 | 0.16 | False | None | None | False | None | False | 501.2272 | 0 | 3652089 | 133178 | None | 015 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & Shuttering Charges For Roof Beam | Cum | 4176.9 | 4176.9 | 4.19 | False | None | None | False | None | False | 17501.211 | 0 | 3652090 | 133178 | None | 016 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & Shuttering Charges For Slab | Cum | 3480.75 | 3480.75 | 9.25 | False | None | None | False | None | False | 32196.9375 | 0 | 3652091 | 133178 | None | 017 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 19.54 | False | None | None | False | None | False | 115120.887 | 0 | 3652092 | 133178 | None | 018 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 14.84 | False | None | None | False | None | False | 99553.398 | 0 | 3652093 | 133178 | None | 019 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | MT | 93929.85 | 93929.85 | 2.6995 | False | None | None | False | None | False | 253563.630075 | 0 | 3652094 | 133178 | None | 020 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 25.0 | False | None | None | False | None | False | 6982.5 | 0 | 3652095 | 133178 | None | 021 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 25.35 | False | None | None | False | None | False | 12616.695 | 0 | 3652096 | 133178 | None | 022 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 17.52 | False | None | None | False | None | False | 146597.724 | 0 | 3652097 | 133178 | None | 023 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 130412.1 | 130412.1 | 0.18 | False | None | None | False | None | False | 23474.178 | 0 | 3652098 | 133178 | None | 024 | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kgs | 176.4 | 176.4 | 141.75 | False | None | None | False | None | False | 25004.7 | 0 | 3652099 | 133178 | None | 025 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Day | 52.5 | 52.5 | 15.19 | False | None | None | False | None | False | 797.475 | 0 | 3652100 | 133178 | None | 026 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 15.19 | False | None | None | False | None | False | 1834.1925 | 0 | 3652101 | 133178 | None | 027 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1066.8 | 1066.8 | 2.0 | False | None | None | False | None | False | 2133.6 | 0 | 3652102 | 133178 | None | 028 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer- in-Charge. | Kgs | 593.25 | 593.25 | 161.28 | False | None | None | False | None | False | 95679.36 | 0 | 3652103 | 133178 | None | 029 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 221.55 | 221.55 | 61.5 | False | None | None | False | None | False | 13625.325 | 0 | 3652104 | 133178 | None | 030 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 241.35 | False | None | None | False | None | False | 94017.8925 | 0 | 3652105 | 133178 | None | 031 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 5.8 | False | None | None | False | None | False | 37861.53 | 0 | 3652106 | 133178 | None | 032 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1717.8 | 1717.8 | 73.16 | False | None | None | False | None | False | 125674.248 | 0 | 3652107 | 133178 | None | 033 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 30 mm thick Both side teak. | Sqm | 4245.15 | 4245.15 | 5.04 | False | None | None | False | None | False | 21395.556 | 0 | 3652108 | 133178 | None | 034 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). | Sqm | 5659.5 | 5659.5 | 5.4 | False | None | None | False | None | False | 30561.3 | 0 | 3652109 | 133178 | None | 035 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). | Sqm | 6004.95 | 6004.95 | 1.35 | False | None | None | False | None | False | 8106.6825 | 0 | 3652110 | 133178 | None | 036 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Nos | 126.0 | 126.0 | 2.0 | False | None | None | False | None | False | 252.0 | 0 | 3652111 | 133178 | None | 037 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 248.85 | 248.85 | 4.0 | False | None | None | False | None | False | 995.4 | 0 | 3652112 | 133178 | None | 038 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 136.5 | 136.5 | 4.0 | False | None | None | False | None | False | 546.0 | 0 | 3652113 | 133178 | None | 039 | Providing M.S. Piano hinges ISI marked IS : 3818 finished with nickel plating and fixing with necessary screws etc., complete. | Nos | 312.9 | 312.9 | 6.0 | False | None | None | False | None | False | 1877.4 | 0 | 3652114 | 133178 | None | 040 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 139.65 | False | None | None | False | None | False | 14663.25 | 0 | 3652115 | 133178 | None | 041 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 194.0 | False | None | None | False | None | False | 27906.9 | 0 | 3652116 | 133178 | None | 042 | Finishing walls with water proofing cement paint of required shade :New
work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 93.45 | 93.45 | 109.54 | False | None | None | False | None | False | 10236.513 | 0 | 3652117 | 133178 | None | 043 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete. | Sqm | 498.75 | 498.75 | 5.76 | False | None | None | False | None | False | 2872.8 | 0 | 3652118 | 133178 | None | 044 | polyurethane based single Component for New surface, Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa- terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa- terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 855.75 | 855.75 | 74.01 | False | None | None | False | None | False | 63334.0575 | 0 |
| 1722347166000 | 0 | None | None | Buildings | For Electrical Work | 79016.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3652119 | 133179 | None | 001 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and runningbefore concreting the slab. The conduit should be tied to thereinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered usingPVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick | Mtr | 66.0 | 66.0 | 90.0 | False | None | None | False | None | False | 5940.0 | 0 | 3652120 | 133179 | None | 002 | Supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick | Mtr | 79.0 | 79.0 | 90.0 | False | None | None | False | None | False | 7110.0 | 0 | 3652121 | 133179 | None | 003 | Supplying and fixing PVC/metal conduit Deep junction box 25mm deep junction box | Mtr | 56.0 | 56.0 | 6.0 | False | None | None | False | None | False | 336.0 | 0 | 3652122 | 133179 | None | 004 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete 10"x7"x3" (254x178x76mm) | Each | 112.0 | 112.0 | 2.0 | False | None | None | False | None | False | 224.0 | 0 | 3652123 | 133179 | None | 005 | Supplying And Fixing Metal Fan Box with Round Hook. | Nos | 160.0 | 160.0 | 4.0 | False | None | None | False | None | False | 640.0 | 0 | 3652124 | 133179 | None | 006 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 10.0 | False | None | None | False | None | False | 2850.0 | 0 | 3652125 | 133179 | None | 007 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 10.0 | False | None | None | False | None | False | 3940.0 | 0 | 3652126 | 133179 | None | 008 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 570.0 | 570.0 | 10.0 | False | None | None | False | None | False | 5700.0 | 0 | 3652127 | 133179 | None | 009 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitabl 3C X 1.5Sq.mm | Mtr | 72.0 | 72.0 | 145.0 | False | None | None | False | None | False | 10440.0 | 0 | 3652128 | 133179 | None | 010 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitabl 4C X 1.5Sq.mm | Mtr | 94.0 | 94.0 | 145.0 | False | None | None | False | None | False | 13630.0 | 0 | 3652129 | 133179 | None | 011 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6Amps 2 Way | Each | 128.0 | 128.0 | 4.0 | False | None | None | False | None | False | 512.0 | 0 | 3652130 | 133179 | None | 012 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6Amps 2way Switch | Nos | 70.0 | 70.0 | 4.0 | False | None | None | False | None | False | 280.0 | 0 | 3652131 | 133179 | None | 013 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module | Each | 137.0 | 137.0 | 10.0 | False | None | None | False | None | False | 1370.0 | 0 | 3652132 | 133179 | None | 014 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.6 Module | Each | 175.0 | 175.0 | 10.0 | False | None | None | False | None | False | 1750.0 | 0 | 3652133 | 133179 | None | 015 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws. | Sq CM | 0.41 | 0.41 | 2000.0 | False | None | None | False | None | False | 820.0 | 0 | 3652134 | 133179 | None | 016 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. | Each | 3031.0 | 3031.0 | 4.0 | False | None | None | False | None | False | 12124.0 | 0 | 3652135 | 133179 | None | 017 | Supplying & fixing retrofit type-PL- LED Lamp . W LED linear source with CCT 6500 degree K, CRI 70%. efficacy80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 18-20 W | Each | 702.0 | 702.0 | 4.0 | False | None | None | False | None | False | 2808.0 | 0 | 3652136 | 133179 | None | 018 | Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulatedwires, required Nos of round blocks and clamps. | Each | 122.0 | 122.0 | 4.0 | False | None | None | False | None | False | 488.0 | 0 | 3652137 | 133179 | None | 019 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 315.0 | 315.0 | 4.0 | False | None | None | False | None | False | 1260.0 | 0 | 3652138 | 133179 | None | 020 | Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | Job | 3750.0 | 3750.0 | 1.0 | False | None | None | False | None | False | 3750.0 | 0 | 3652139 | 133179 | None | 021 | Supplying and fixing regular MCB distribution boards on wall/ wood board / flush mounting using required clamps, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase / 3 phase / single door with powdercoated painting. Made out of 14 SWG MS enclosure. | Each | 3044.0 | 3044.0 | 1.0 | False | None | None | False | None | False | 3044.0 | 0 |
| 1722347167000 | 0 | None | None | Buildings | Repairs to Govt Higher Primary School at Kavithal Village in Manvi / Sirwar Taluka of Raichur District. | 714825.16 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3652140 | 133180 | None | 001 | Providing and laying water proofing treatment to the Roof with PU based
single component elastomeric pure polyurethane based coating on New
terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing
membrane that is highly elastic with elongation greater than
400% and tensile strength greater than 2MPa as per ASTM D412. The
waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve
final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy
primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing
membrane. The finished cost to include surface preparation,
making coving at Junction, Bore Packing, treatment of construction joints
completely as per specification. | Sqm | 857.85 | 857.85 | 337.5 | False | None | None | False | None | False | 289524.375 | 0 | 3652141 | 133180 | None | 002 | Finishing with Deluxe Multi surface paint system for interiors and exteriors
using Primer as per manufacturers specifications: Two coats applied on
walls @ 1.25 L/10 m² over and including one coat of Special primer applied
@ 0.75 L/10 m² with paint of approved quality to give an even shade, after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree
angle with 10 years life) | Sqm | 186.9 | 186.9 | 1590.2 | False | None | None | False | None | False | 297208.38 | 0 | 3652142 | 133180 | None | 003 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:1990 | Rmtr | 44.21 | 44.21 | 450.0 | False | None | None | False | None | False | 19894.5 | 0 | 3652143 | 133180 | None | 004 | Supplying6Aflushtypesocketand6AflushtypeSPswitcheithersurface/flushmountinginexistinggangboxorin4mmthickplasticsheetandfixingoveraflushmountedwoodenboxandwiringusingnecessary capacity wires as required as per IS 1293 | Nos | 134.4 | 134.4 | 55.0 | False | None | None | False | None | False | 7392.0 | 0 | 3652144 | 133180 | None | 005 | Supplyingandfixingsurface/flushmountingunbreakablePVCmodularboxsuitableformountingmodularswitchplateswithduegroovecuttinginBrick/C.Cwall,includingnecessaryrawlplugs,Machine/NF screws etc., complete.4-5 Way | Point | 143.85 | 143.85 | 35.0 | False | None | None | False | None | False | 5034.75 | 0 | 3652145 | 133180 | None | 006 | Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeontheexistingmetal/PVC box.4 Module | Point | 183.75 | 183.75 | 50.0 | False | None | None | False | None | False | 9187.5 | 0 | 3652146 | 133180 | None | 007 | Fixingalltypesandallcapacitiesoffluorescent/falseceiling/spotlight/CFL/LEDfittingsindooronthewall/ceiling/rafters/girdersusing23/0.0076"twintwistedPVCinsulatedwires,requiredNosofround blocks and clamps.On wall/ ceiling / Rafter / Girders | Each | 128.1 | 128.1 | 25.0 | False | None | None | False | None | False | 3202.5 | 0 | 3652147 | 133180 | None | 008 | Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3withShortcircuitbreakingcapacityof10KandcompletewiringasrequiredconfirmingtoIEC60898 40-63 Amps TPN6-32 Amps DP | Point | 775.95 | 775.95 | 7.0 | False | None | None | False | None | False | 5431.65 | 0 | 3652148 | 133180 | None | 009 | Supplyingcapacitortypeceilingfancompletewithdownrodblades,shackle,canopiesetc,foroperationon230V,50cycles.SinglephaseACsupplyconformingtoISS-374-1979andwithdoubleballbearingsystem56" Sweep (1400 mm) Regular model | Each | 3181.5 | 3181.5 | 16.0 | False | None | None | False | None | False | 50904.0 | 0 | 3652149 | 133180 | None | 010 | FabricatingsupplyingandmountingMSboxmadeout.SWGsuitableforfloor/wallmounting,fullyweatherproofwithprovisionforbetterheatdissipation,providedwithhingedfrontcover,equippedwithtamperprooflockingarrangements,withsuitablesizeclampswithnecessarycableentrypipewithglandandboxshouldbefinishedwith7tankstreatmentwithpowdercoatedpaintand finally finished with approved colour etc., complete 16 SWG | Sq CM | 0.47 | 0.47 | 11500.0 | False | None | None | False | None | False | 5405.0 | 0 | 3652150 | 133180 | None | 011 | Supplying.Arated3phasewithneutralbusbarusingrequiredcapacityelectrolyticaluminiumstripscoveredwithheatshrinkablecolouredPVCsleeve,mountedonphenolic/FRP/DMCinsulatorwhicharemountedonpowdercoated40x6mmM.S.flatframeworkinexistingpanelboard.ThebusbarshallhavesuitableholesforterminationofincomingandoutgoingcablesasperISspecification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips | Each | 3606.75 | 3606.75 | 6.0 | False | None | None | False | None | False | 21640.5 | 0 |
| 1722347167000 | 0 | None | None | Buildings | Construction of Two Rooms to Govt Higher Primary School at Kavital Village in Manvi / Sirwar Taluka of Raichur District. | 2585361.77 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3652151 | 133181 | None | 001 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 107.1 | 107.1 | 79.63 | False | None | None | False | None | False | 8528.373 | 0 | 3652152 | 133181 | None | 002 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 10.53 | False | None | None | False | None | False | 62624.016 | 0 | 3652153 | 133181 | None | 003 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Footing | Cum | 6961.5 | 6961.5 | 9.72 | False | None | None | False | None | False | 67665.78 | 0 | 3652154 | 133181 | None | 004 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Column | Cum | 6961.5 | 6961.5 | 6.25 | False | None | None | False | None | False | 43509.375 | 0 | 3652155 | 133181 | None | 005 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Plinth Beam | Cum | 6961.5 | 6961.5 | 4.23 | False | None | None | False | None | False | 29447.145 | 0 | 3652156 | 133181 | None | 006 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Lintel | Cum | 6961.5 | 6961.5 | 1.5 | False | None | None | False | None | False | 10442.25 | 0 | 3652157 | 133181 | None | 007 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Chajja | Cum | 6961.5 | 6961.5 | 0.32 | False | None | None | False | None | False | 2227.68 | 0 | 3652158 | 133181 | None | 008 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Roof Beam | Cum | 6961.5 | 6961.5 | 8.16 | False | None | None | False | None | False | 56805.84 | 0 | 3652159 | 133181 | None | 009 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Slab | Cum | 6961.5 | 6961.5 | 15.78 | False | None | None | False | None | False | 109852.47 | 0 | 3652160 | 133181 | None | 010 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & Shuttering Charges For Footing | Cum | 208.84 | 208.84 | 9.72 | False | None | None | False | None | False | 2029.9248 | 0 | 3652161 | 133181 | None | 011 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & Shuttering Charges For Columns | Cum | 4873.05 | 4873.05 | 6.25 | False | None | None | False | None | False | 30456.5625 | 0 | 3652162 | 133181 | None | 012 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & Shuttering Charges For Plith Beam | Cum | 3480.75 | 3480.75 | 4.23 | False | None | None | False | None | False | 14723.5725 | 0 | 3652163 | 133181 | None | 013 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & Shuttering Charges For Lintel Beam | Cum | 4176.9 | 4176.9 | 1.5 | False | None | None | False | None | False | 6265.35 | 0 | 3652164 | 133181 | None | 014 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & Shuttering Charges For Chajja | Cum | 3132.67 | 3132.67 | 0.32 | False | None | None | False | None | False | 1002.4544 | 0 | 3652165 | 133181 | None | 015 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & Shuttering Charges For Roof Beam | Cum | 4176.9 | 4176.9 | 8.16 | False | None | None | False | None | False | 34083.504 | 0 | 3652166 | 133181 | None | 016 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & Shuttering Charges For Slab | Cum | 3480.75 | 3480.75 | 15.78 | False | None | None | False | None | False | 54926.235 | 0 | 3652167 | 133181 | None | 017 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 28.11 | False | None | None | False | None | False | 165611.4705 | 0 | 3652168 | 133181 | None | 018 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 20.02 | False | None | None | False | None | False | 134303.169 | 0 | 3652169 | 133181 | None | 019 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | MT | 93929.85 | 93929.85 | 4.5961 | False | None | None | False | None | False | 431710.983585 | 0 | 3652170 | 133181 | None | 020 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 41.0 | False | None | None | False | None | False | 11451.3 | 0 | 3652171 | 133181 | None | 021 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 38.0 | False | None | None | False | None | False | 18912.6 | 0 | 3652172 | 133181 | None | 022 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8621.55 | 8621.55 | 24.58 | False | None | None | False | None | False | 211917.699 | 0 | 3652173 | 133181 | None | 023 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 130412.1 | 130412.1 | 0.36 | False | None | None | False | None | False | 46948.356 | 0 | 3652174 | 133181 | None | 024 | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kgs | 192.15 | 192.15 | 337.5 | False | None | None | False | None | False | 64850.625 | 0 | 3652175 | 133181 | None | 025 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 52.5 | 52.5 | 30.38 | False | None | None | False | None | False | 1594.95 | 0 | 3652176 | 133181 | None | 026 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 120.75 | 120.75 | 30.38 | False | None | None | False | None | False | 3668.385 | 0 | 3652177 | 133181 | None | 027 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1066.8 | 1066.8 | 4.0 | False | None | None | False | None | False | 4267.2 | 0 | 3652178 | 133181 | None | 028 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer- in-Charge. | Kgs | 593.25 | 593.25 | 269.37 | False | None | None | False | None | False | 159803.7525 | 0 | 3652179 | 133181 | None | 029 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 221.55 | 221.55 | 102.78 | False | None | None | False | None | False | 22770.909 | 0 | 3652180 | 133181 | None | 030 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 404.25 | 404.25 | 347.82 | False | None | None | False | None | False | 140606.235 | 0 | 3652181 | 133181 | None | 031 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 15.11 | False | None | None | False | None | False | 98635.8135 | 0 | 3652182 | 133181 | None | 032 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1717.8 | 1717.8 | 116.15 | False | None | None | False | None | False | 199522.47 | 0 | 3652183 | 133181 | None | 033 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 30 mm thick Both side teak. | Sqm | 4245.15 | 4245.15 | 10.08 | False | None | None | False | None | False | 42791.112 | 0 | 3652184 | 133181 | None | 034 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). | Sqm | 5659.5 | 5659.5 | 10.8 | False | None | None | False | None | False | 61122.6 | 0 | 3652185 | 133181 | None | 035 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). | Sqm | 6004.95 | 6004.95 | 2.7 | False | None | None | False | None | False | 16213.365 | 0 | 3652186 | 133181 | None | 036 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Nos | 126.0 | 126.0 | 4.0 | False | None | None | False | None | False | 504.0 | 0 | 3652187 | 133181 | None | 037 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 248.85 | 248.85 | 8.0 | False | None | None | False | None | False | 1990.8 | 0 | 3652188 | 133181 | None | 038 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 136.5 | 136.5 | 8.0 | False | None | None | False | None | False | 1092.0 | 0 | 3652189 | 133181 | None | 039 | Providing M.S. Piano hinges ISI marked IS : 3818 finished with nickel plating and fixing with necessary screws etc., complete. | Nos | 312.0 | 312.0 | 12.0 | False | None | None | False | None | False | 3744.0 | 0 | 3652190 | 133181 | None | 040 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 218.18 | False | None | None | False | None | False | 22908.9 | 0 | 3652191 | 133181 | None | 041 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 316.09 | False | None | None | False | None | False | 45469.5465 | 0 | 3652192 | 133181 | None | 042 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 134.51 | False | None | None | False | None | False | 24574.977 | 0 | 3652193 | 133181 | None | 043 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete. | Sqm | 498.75 | 498.75 | 11.52 | False | None | None | False | None | False | 5745.6 | 0 | 3652194 | 133181 | None | 044 | polyurethane based single Component for New surface, Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa- terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa- terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 855.75 | 855.75 | 126.25 | False | None | None | False | None | False | 108038.4375 | 0 |
| 1722347167000 | 0 | None | None | Buildings | For Electrical Works | 154222.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3652195 | 133182 | None | 001 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and runningbefore concreting the slab. The conduit should be tied to thereinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered usingPVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick | Mtr | 66.0 | 66.0 | 210.0 | False | None | None | False | None | False | 13860.0 | 0 | 3652196 | 133182 | None | 002 | Supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick | Mtr | 79.0 | 79.0 | 210.0 | False | None | None | False | None | False | 16590.0 | 0 | 3652197 | 133182 | None | 003 | Supplying and fixing PVC/metal conduit Deep junction box 25mm deep junction box | Mtr | 56.0 | 56.0 | 10.0 | False | None | None | False | None | False | 560.0 | 0 | 3652198 | 133182 | None | 004 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete 10"x7"x3" (254x178x76mm) | Each | 112.0 | 112.0 | 4.0 | False | None | None | False | None | False | 448.0 | 0 | 3652199 | 133182 | None | 005 | Supplying And Fixing Metal Fan Box with Round Hook. | Nos | 160.0 | 160.0 | 8.0 | False | None | None | False | None | False | 1280.0 | 0 | 3652200 | 133182 | None | 006 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 16.0 | False | None | None | False | None | False | 4560.0 | 0 | 3652201 | 133182 | None | 007 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 16.0 | False | None | None | False | None | False | 6304.0 | 0 | 3652202 | 133182 | None | 008 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 570.0 | 570.0 | 16.0 | False | None | None | False | None | False | 9120.0 | 0 | 3652203 | 133182 | None | 009 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitabl 3C X 1.5Sq.mm | Mtr | 72.0 | 72.0 | 325.0 | False | None | None | False | None | False | 23400.0 | 0 | 3652204 | 133182 | None | 010 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitabl 4C X 1.5Sq.mm | Mtr | 94.0 | 94.0 | 325.0 | False | None | None | False | None | False | 30550.0 | 0 | 3652205 | 133182 | None | 011 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6Amps 2 Way | Each | 128.0 | 128.0 | 8.0 | False | None | None | False | None | False | 1024.0 | 0 | 3652206 | 133182 | None | 012 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6Amps 2way Switch | Nos | 70.0 | 70.0 | 8.0 | False | None | None | False | None | False | 560.0 | 0 | 3652207 | 133182 | None | 013 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 Module | Each | 137.0 | 137.0 | 16.0 | False | None | None | False | None | False | 2192.0 | 0 | 3652208 | 133182 | None | 014 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.6 Module | Each | 175.0 | 175.0 | 16.0 | False | None | None | False | None | False | 2800.0 | 0 | 3652209 | 133182 | None | 015 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws. | Sq CM | 0.41 | 0.41 | 2000.0 | False | None | None | False | None | False | 820.0 | 0 | 3652210 | 133182 | None | 016 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. | Each | 3031.0 | 3031.0 | 8.0 | False | None | None | False | None | False | 24248.0 | 0 | 3652211 | 133182 | None | 017 | Supplying & fixing retrofit type-PL- LED Lamp . W LED linear source with CCT 6500 degree K, CRI 70%. efficacy80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 18-20 W | Each | 702.0 | 702.0 | 8.0 | False | None | None | False | None | False | 5616.0 | 0 | 3652212 | 133182 | None | 018 | Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulatedwires, required Nos of round blocks and clamps. | Each | 122.0 | 122.0 | 8.0 | False | None | None | False | None | False | 976.0 | 0 | 3652213 | 133182 | None | 019 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 315.0 | 315.0 | 8.0 | False | None | None | False | None | False | 2520.0 | 0 | 3652214 | 133182 | None | 020 | Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | Job | 3750.0 | 3750.0 | 1.0 | False | None | None | False | None | False | 3750.0 | 0 | 3652215 | 133182 | None | 021 | Supplying and fixing regular MCB distribution boards on wall/ wood board / flush mounting using required clamps, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase / 3 phase / single door with powdercoated painting. Made out of 14 SWG MS enclosure. | Each | 3044.0 | 3044.0 | 1.0 | False | None | None | False | None | False | 3044.0 | 0 |
| 1722347167000 | 0 | None | None | Buildings | Repairs to Govt Higher Primary School at Kavital Village in Manvi / Sirwar Taluka of Raichur District. | 305453.81 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3652216 | 133183 | None | 001 | Providing and laying water proofing treatment to the Roof with PU based
single component elastomeric pure polyurethane based coating on New
terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing
membrane that is highly elastic with elongation greater than
400% and tensile strength greater than 2MPa as per ASTM D412. The
waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve
final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy
primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing
membrane. The finished cost to include surface preparation,
making coving at Junction, Bore Packing, treatment of construction joints
completely as per specification | Sqm | 857.85 | 857.85 | 106.87 | False | None | None | False | None | False | 91678.4295 | 0 | 3652217 | 133183 | None | 002 | Providing and laying Polished Glazed Vitrified tiles with thickness 10
mm in floor with different sizes with water absorption less than 0.08%
and conforming to IS:15622, of approved brand & manufacturer, in all
colours and shade, laid with cement based high polymer modified quick
set tile adhesive (water based) conforming to IS : 15477, in average 6 mm
thickness, including grouting of joints (Payment for grouting of joints to
be made separately Size of Tile 600x600 mm | Sqm | 1392.3 | 1392.3 | 112.6 | False | None | None | False | None | False | 156772.98 | 0 | 3652218 | 133183 | None | 003 | Finishing walls with textured exterior paint of required shade :New work
(Two coats applied @ 3.28 L/10 m²) over and including priming coat of
exterior primer applied @ 2.20kg/10 m² to give an even shade after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge | Sqm | 218.4 | 218.4 | 261.0 | False | None | None | False | None | False | 57002.4 | 0 |
|
|
---|