createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1722139580314
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd337000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose26-08-2024 17:30:00
tenderQueryClose21-08-2024 16:30:00
technicalBidOpen28-08-2024 11:00:00
publishedDate01-08-2024 11:14:31
publishedByPostUKPRR_EE_DIV3_JKD
publishedByUserKPE11247 - VISHWANATH G MIKKAL
bidValidityPeriod180
noOfCalls1
preBidMeetingDate23-08-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypePERCENTAGE
denominationTypeTextPercentage
retenderedYnNone
percentageRateTypeTextSingle Rate
contactPersonS B Shegunasi
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9164031043
tenderSupplierListNone
tenderSchedule
createdTs1722139580365
version4
createdDateNone
modifiedDateNone
tenderNumberUKPRR/2024-25/BD/WORK_INDENT25
titleConstruction of Shelter in Burial Ground at Bilagi Cross-IV, Yalligutti, Honnihal, Kandagalla, Yatnatti-Badaradinni RCs and Crematorium Building in Burial Ground at Bilgi Cross-IV, Yalligutti, Honnihal, Kandagalla, Yatnatti-Badaradinni RCs and Ranga Mandir at Bilgi Cross-IV Yatnatti Badaradinni and ELSR at Yatnatti RC, Badaradinni RC and 2 room school blding (Extra) at Bilagi Cross-IV RC and Toilet in School ground at Yalligutti RC of Bilagi Tq of Bagalkot Dist (Package 9)
descriptionConstruction of Shelter in Burial Ground at 1) Bilagi Cross-IV, 2) Yalligutti RC, 3) Honnihal RC, 4) Kandagalla RC, 5) Yatnatti-Badaradinni RC and Construction of Crematorium Building in Burial Ground at 6) Bilagi Cross-IV, 7) Yalligutti RC, 8) Honnihal RC, 9) Kandagalla RC, 10) Yatnatti-Badaradinni RC and Construction of Ranga Mandir at 11) Bilagi Cross-IV RC, 12) Yatnatti RC, 13) Badaradinni RC and Construction of ELSR at 14) Yatnatti RC, 15) Badaradinni RC and Construction of Two room school building (Extra) at 16) Bilagi Cross-IV RC and Construction of Toilet in School ground at 17) Yalligutti RC of Bilagi Tq of Bagalkot Dist (Package-9)
categoryWORKS
categoryTextWorks
ecv22500000.00
deptNameUpper Krishna Rehabilitation and Resettlement
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location5950
locationNameUKPRR Executive Engineer Office Div No 3 Jamkhandi
provisionalAmount22500000.0
groupOverheadTotal97492.36
fileNumberUKPRR/SD5/08
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17221395800000NoneNoneBuildingsConstruction of Shelter in Burial Ground at Bilagi Cross-IV, Yalligutti, Honnihal, Kandagalla, Yatnatti-Badaradinni RCs and Crematorium Building in Burial Ground at Bilgi Cross-IV, Yalligutti, Honnihal, Kandagalla, Yatnatti-Badaradinni RCs and Ranga Mandir at Bilgi Cross-IV Yatnatti Badaradinni and ELSR at Yatnatti RC, Badaradinni RC and 2 room school blding (Extra) at Bilagi Cross-IV RC and Toilet in School ground at Yalligutti RC of Bilagi Tq of Bagalkot Dist (Package 9)22402507.64
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3635835132264Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work as per directions o with all lead and lift.Cum86.1486.141062.46FalseNoneNoneFalseNoneFalse91520.30440
3635836132264Nonecode02Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.(Without Roller Compaction) as per directions of Engineer-in-charge with all lead and lift.Cum450.64450.64396.49FalseNoneNoneFalseNoneFalse178674.25360
3635837132264Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates. as per directions of Engineer-in-charge with all lead and lift.Cum6143.086143.0896.11FalseNoneNoneFalseNoneFalse590411.41880
3635838132264Nonecode04Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) as per directions of Engineer-in-charge with all lead and lift.Cum5605.05605.0150.42FalseNoneNoneFalseNoneFalse843104.10
3635839132264Nonecode05Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work with all lead and liftCum7894.27894.2124.83FalseNoneNoneFalseNoneFalse985432.9860
3635840132264Nonecode06Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates as per directions of Engineer-in-charge with all lead and lift.Cum6759.046759.0489.26FalseNoneNoneFalseNoneFalse603311.91040
3635841132264Nonecode07Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. in foundation (Incl formwork and excluding cost of steel reinforcement) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per directions of Engineer-in-charge with all lead and lift.Cum7878.347878.3470.49FalseNoneNoneFalseNoneFalse555344.18660
3635842132264Nonecode08Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. in Columns (Incl formwork and excluding cost of steel reinforcement) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per directions of Engineer-in-charge with all lead and lift.Cum12401.0912401.0971.95FalseNoneNoneFalseNoneFalse892258.42550
3635843132264Nonecode09Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. in RCC walls/Beams (Incl formwork and excluding cost of steel reinforcement) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per directions of Engineer-in-charge with all lead and lift.Cum10942.1410942.14335.77FalseNoneNoneFalseNoneFalse3674042.34780
3635844132264Nonecode10Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, strutting, plywood / steel form work , Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) (Minimum cement content: 340 kgs (6.80 bags)). RCC M25 Design Mix with 20mm aggregate for level 0m to 6m height as per directions of Engineer-in-charge with all lead and lift.Cum9784.569784.5612.78FalseNoneNoneFalseNoneFalse125046.67680
3635845132264Nonecode11Providing and laying in position Reinforced cement concrete for columns, braces and ring beam above ground level. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cement mortar 1:3, 12 mm thick, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags)). RCC M30 Design Mix with 20mm aggregate for level 6m to 9m height as per directions of Engineer-in-charge with all lead and lift.Cum16202.5816202.5819.2FalseNoneNoneFalseNoneFalse311089.5360
3635846132264Nonecode12Providing and laying in position Reinforced cement concrete for shell portion, bottom dome / slab and ribs over the staging.The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cement mortar 1:3, 12 mm thick and CM plastering 1:3 proportion 20mm thick for inside with an admixture of water proof compound of requisite proportion of approved quality, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications.(Contractor will make his own arrangements for procuring water for testing). (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20 bags)).RCC M30 Design Mix with 20mm aggregate for level 6m to 9m height. as per directions of Engineer-in-charge with all lead and lift.Cum23959.923959.937.5FalseNoneNoneFalseNoneFalse898496.250
3635847132264Nonecode13Providing and laying in position Reinforced cement concrete for side walls of water tank over the staging above the ground level. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes with plastering and smooth finishing the exposed faces in cement mortar 1:3, 12 mm thick and CM plastering 1:3 proportion 20mm thick for inside with an admixture of water proof compound of requisite proportion of approved quality, labour,centering, scaffolding, staging, strutting, plywood/ steel form work , Usage charges of machinery, curing and all other appurtenances required to complete the work as per design and technical specifications.(Contractor will make his own arrangements for procuring water for testing). (The cost of steel reinforcement, dowel bars to be paid separately). (Minimum cement content: 360 kgs (7.20bags)).RCC M30 Design Mix with 20mm aggregate for level and upto 9-12 m height as per directions of Engineer-in-charge with all lead and lift.Cum27416.1227416.1217.53FalseNoneNoneFalseNoneFalse480604.58360
3635848132264Nonecode14Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) with all lead and lift as per directions of Engineer-in-charge with all lead and lift.Kgs108.56108.5650611.37FalseNoneNoneFalseNoneFalse5494370.32720
3635849132264Nonecode15Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. as per directions of Engineer-in-charge with all lead and lift.Sqm1420.721420.72775.42FalseNoneNoneFalseNoneFalse1101654.70240
3635850132264Nonecode16Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm as per directions of Engineer-in-charge with all lead and lift.Sqm1354.641354.6433.82FalseNoneNoneFalseNoneFalse45813.92480
3635851132264Nonecode17Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete as per directions of Engineer-in-charge with all lead and lift.Sqm1149.321149.3298.28FalseNoneNoneFalseNoneFalse112955.16960
3635852132264Nonecode18Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding as per directions of Engineer-in-charge with all lead and lift.Kgs171.1171.110202.22FalseNoneNoneFalseNoneFalse1745599.8420
3635853132264Nonecode19Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm251.34251.343841.81FalseNoneNoneFalseNoneFalse965600.52540
3635854132264Nonecode20Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm123.9123.91017.52FalseNoneNoneFalseNoneFalse126070.7280
3635855132264Nonecode21Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) with all lead and lift and as directed by Engineer in charge of the workSqm7564.987564.989.72FalseNoneNoneFalseNoneFalse73531.60560
3635856132264Nonecode22Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) with all lead and lift and as directed by Engineer in charge of the workSqm5746.65746.65.4FalseNoneNoneFalseNoneFalse31031.640
3635857132264Nonecode23Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm77.8877.883383.36FalseNoneNoneFalseNoneFalse263496.07680
3635858132264Nonecode24Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeKgs160.48160.48859.39FalseNoneNoneFalseNoneFalse137914.90720
3635859132264Nonecode25Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required and as per directions of Engineer-in-charge.Sqm656.08656.08247.68FalseNoneNoneFalseNoneFalse162497.89440
3635860132264Nonecode26Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) as per directions of Engineer-in-charge.Rmtr425.98425.9828.8FalseNoneNoneFalseNoneFalse12268.2240
3635861132264Nonecode27Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm106.2106.2770.36FalseNoneNoneFalseNoneFalse81812.2320
3635862132264Nonecode28Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.cm3.543.5411250.0FalseNoneNoneFalseNoneFalse39825.00
3635863132264Nonecode29Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications with all lead and lift and as directed by Engineer in charge of the workCum88905.9288905.920.3465FalseNoneNoneFalseNoneFalse30805.901280
3635864132264Nonecode30Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) with all lead and lift and as directed by Engineer in charge of the workSqm5376.085376.0810.18FalseNoneNoneFalseNoneFalse54728.49440
3635865132264Nonecode31Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in chargeSqm48.3848.3819.74FalseNoneNoneFalseNoneFalse955.02120
3635866132264Nonecode32Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below, with wall thickness 2.0 mm corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section as per specifications and as per directions of Engineer in chargeRmtr270.22270.2247.2FalseNoneNoneFalseNoneFalse12754.3840
3635867132264Nonecode33Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges with all lead and lift and as directed by Engineer in charge of the workSqm338.66338.6614.28FalseNoneNoneFalseNoneFalse4836.06480
3635868132264Nonecode34Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications with all lead and lift and as directed by Engineer in charge of the workNos1752.31752.34.0FalseNoneNoneFalseNoneFalse7009.20
3635869132264Nonecode35Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m as per directions of Engineer-in-charge with all lead and lift.Cum554.6554.693.15FalseNoneNoneFalseNoneFalse51660.990
3635870132264Nonecode36Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. as per directions of the Engineer-in-Charge with all lead and lift.Cum240.72240.7293.15FalseNoneNoneFalseNoneFalse22423.0680
3635871132264Nonecode37Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3 with all lead and lift as per directions of the Engineer-in-Charge.Rmtr312.23312.23230.0FalseNoneNoneFalseNoneFalse71812.90
3635872132264Nonecode38Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 80 mm dia GM (Copper alloy) Gate valves with all lead and lift as per directions of the Engineer-in-Charge.Nos2244.362244.3610.0FalseNoneNoneFalseNoneFalse22443.60
3635873132264Nonecode39Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 1000 litre capacity) Specification No.KBS 13.22 For 1000 Ltrs with all lead and lift as per directions of the Engineer-in-Charge.Nos8057.048057.042.0FalseNoneNoneFalseNoneFalse16114.080
3635874132264Nonecode40Ladder inside the container: Providing anodized aluminium ladder using 65mm x 32mm x 3.0mm ‘C’ section for ladder side channel x 25mm dia., flutal pipe for Rungs at 250mm c/c ladder fixed at an angle of 70 degrees to horizontal including necessary 25mm dia., G.I. shutters with necessary G.I. fasteners for bracing the ladders to the Tank walls to prevent buckling of the ladder with necessary (M-15) bed for embedding the ladder bottom complete as per directions of Engineer-in-charge.Rmtr3656.823656.827.4FalseNoneNoneFalseNoneFalse27060.4680
3635875132264Nonecode41Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle of 65 x 65 x 10mm as per directions of Engineer-in-charge.Rmtr5601.465601.4631.35FalseNoneNoneFalseNoneFalse175605.7710
3635876132264Nonecode42Providing and fixing RCC final and ventilators as per approved design and specifications with form works and protected with wire mesh. The plinth to be of RCC circular pillars and canopy with an ornamental finish at top. The first 22.5 cms height to be covered with RCC panelling as per detailed drawings etc. with all lead and lifts and excluding reinforcement steel. For over head tanks upto 2.5 lakhs capacity with all lead and lift as per directions of the Engineer-in-Charge.Nos6785.06785.02.0FalseNoneNoneFalseNoneFalse13570.00
3635877132264Nonecode43Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc with all lead and lift as per directions of the Engineer-in-Charge.Nos2490.982490.982.0FalseNoneNoneFalseNoneFalse4981.960
3635878132264Nonecode44Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of 150mm dia with all lead and lift as per directions of the Engineer-in-Charge.Nos2725.82725.84.0FalseNoneNoneFalseNoneFalse10903.20
3635879132264Nonecode45Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of 100mm dia with all lead and lift as per directions of the Engineer-in-Charge.Nos2132.262132.266.0FalseNoneNoneFalseNoneFalse12793.560
3635880132264Nonecode46Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of 80mm dia with all lead and lift as per directions of the Engineer-in-Charge.Nos1800.681800.682.0FalseNoneNoneFalseNoneFalse3601.360
3635881132264Nonecode47Supplying, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DIflanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete. For double flanged CI pipes of 100mm dia with all lead and lift as per directions of the Engineer-in-Charge.Rmtr4665.94665.9120.0FalseNoneNoneFalseNoneFalse559908.00
3635882132264Nonecode48Supplying, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DIflanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete. For double flanged CI pipes of 100mm dia. For double flanged CI pipes of 150mm dia with all lead and lift as per directions of the Engineer-in-Charge.Rmtr7498.257498.2526.0FalseNoneNoneFalseNoneFalse194954.50
3635883132264Nonecode49Supplying, Laying and Jointing Cast Iron (CI) double flanged pipes true to line / hoisting of DIflanged pipe in position and aligning to correct plumb, including cost of jointing materials, conveying to work spot with all lead and lifts etc.complete. For double flanged CI pipes of 100mm dia. For double flanged CI pipes of 80mm dia with all lead and lift as per directions of the Engineer-in-Charge.Rmtr3512.573512.5726.0FalseNoneNoneFalseNoneFalse91326.820
3635884132264Nonecode50Supplying Ductile Iron Push on special confirming to IS 9523:2000 - All Double Socket Duck Foot DI Bends: 80 X 900 with all lead and lift as per directions of the Engineer-in-Charge.Nos2790.72790.72.0FalseNoneNoneFalseNoneFalse5581.40
3635885132264Nonecode51Supplying Ductile Iron Push on special confirming to IS 9523:2000 - All Double Socket Duck Foot DI Bends: 100 X 900 with all lead and lift as per directions of the Engineer-in-Charge.Nos3614.343614.342.0FalseNoneNoneFalseNoneFalse7228.680
3635886132264Nonecode52Supplying Ductile Iron Push on special confirming to IS 9523:2000 - All Double Socket Duck Foot DI Bends: 150 X 900 with all lead and lift as per directions of the Engineer-in-Charge.Nos6091.166091.162.0FalseNoneNoneFalseNoneFalse12182.320
3635887132264Nonecode53Supply and fixing of DI Double flanged wafer type ( Concentric) / double eccentrically disc, Resilent seated Butterfly valves confoming to BS EN 593 / IS 13095 with shaft shall be of stainless steel AISI 410/431/420 and renewable soft seal on the disc and body seat face of nickel weld overlay micro finished/Bolted External Seat of SS 304 / CF8 with Powder orliquid epoxy coating with minimum thickness of 250 microns applied on both body and disc inside and outside. Fce to face dimensions as per EN 558-1 Basic series 14 (DIN 3203 F4) or AWWA C 504 : 80 or IS 13095. The valves shall be supplied along with the required number of standard make galvanized Bolts and nuits. The flange drilling standard is IS 1538. hence, drilling of hole in the valves shall match with the pipe flange drilling standard, the valves are to be suitabale for buried operaion with the gear box sealed and lubricated for life time opration. ( All the drilled holes in the body shall be of though holes, no tapped holes will be allowed) For PN 10.0 80mm dia with all lead and lift as per directions of the Engineer-in-Charge.Nos13512.1813512.182.0FalseNoneNoneFalseNoneFalse27024.360
3635888132264Nonecode54Supply and fixing of DI Double flanged wafer type ( Concentric) / double eccentrically disc, Resilent seated Butterfly valves confoming to BS EN 593 / IS 13095 with shaft shall be of stainless steel AISI 410/431/420 and renewable soft seal on the disc and body seat face of nickel weld overlay micro finished/Bolted External Seat of SS 304 / CF8 with Powder orliquid epoxy coating with minimum thickness of 250 microns applied on both body and disc inside and outside. Fce to face dimensions as per EN 558-1 Basic series 14 (DIN 3203 F4) or AWWA C 504 : 80 or IS 13095. The valves shall be supplied along with the required number of standard make galvanized Bolts and nuits. The flange drilling standard is IS 1538. hence, drilling of hole in the valves shall match with the pipe flange drilling standard, the valves are to be suitabale for buried operaion with the gear box sealed and lubricated for life time opration. ( All the drilled holes in the body shall be of though holes, no tapped holes will be allowed) For PN 10.0 100mm dia with all lead and lift as per directions of the Engineer-in-Charge.Nos13185.3213185.324.0FalseNoneNoneFalseNoneFalse52741.280
3635889132264Nonecode55Supply and fixing of DI Double flanged wafer type ( Concentric) / double eccentrically disc, Resilent seated Butterfly valves confoming to BS EN 593 / IS 13095 with shaft shall be of stainless steel AISI 410/431/420 and renewable soft seal on the disc and body seat face of nickel weld overlay micro finished/Bolted External Seat of SS 304 / CF8 with Powder orliquid epoxy coating with minimum thickness of 250 microns applied on both body and disc inside and outside. Fce to face dimensions as per EN 558-1 Basic series 14 (DIN 3203 F4) or AWWA C 504 : 80 or IS 13095. The valves shall be supplied along with the required number of standard make galvanized Bolts and nuits. The flange drilling standard is IS 1538. hence, drilling of hole in the valves shall match with the pipe flange drilling standard, the valves are to be suitabale for buried operaion with the gear box sealed and lubricated for life time opration. ( All the drilled holes in the body shall be of though holes, no tapped holes will be allowed) For PN 10.0 150mm dia with all lead and lift as per directions of the Engineer-in-Charge.Nos20406.9220406.922.0FalseNoneNoneFalseNoneFalse40813.840
3635890132264Nonecode56Providing and fixing gauge with iron sheet or enamelled guage plate of 3mm to 4mm thick, 0.23 M width with copper floats indicators and flexible nylone wires, painting figures with approved enamel paint etc. with all lead and lifts, complete for: Enamelled guage plate for 2.5 m depth with all lead and lift as per directions of the Engineer-in-Charge.Nos4704.664704.666.0FalseNoneNoneFalseNoneFalse28227.960
3635891132264Nonecode57Supplying and fixing lightening arrestor with aluminium strip 25mm x 3mm size including finial and grounding, aluminium strip to be embeded in one of the columns in and independent GI conduit of 40mm dia. pipe suitably jointed by collars with all specials with all lead and lifts etc. complete for: For Over Head Tanks upto 12m staging with all lead and lift as per directions of the Engineer-in-Charge.Nos12293.2412293.242.0FalseNoneNoneFalseNoneFalse24586.480
3635892132264Nonecode58Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 56" Sweep (1400 mm) Regular model with all lead and lift as per directions of the Engineer-in-Charge.Nos2560.62560.64.0FalseNoneNoneFalseNoneFalse10242.40
3635893132264Nonecode59Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than80 lumen per W, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 15W, 6500K with all lead and lift as per directions of the Engineer-in-Charge.Nos397.66397.6614.0FalseNoneNoneFalseNoneFalse5567.240
3635894132264Nonecode60Supplying heavy gauge PVC conduit pipe 25 mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. (25 mm dia 2 mm thick) as per directions of Engineer-in-charge.Rmtr82.682.6120.0FalseNoneNoneFalseNoneFalse9912.00
3635895132264Nonecode61Supplying heavy gauge PVC Conduit Pipe 25mm dia 2 mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. as per directions of Engineer-in-charge.Rmtr94.494.480.0FalseNoneNoneFalseNoneFalse7552.00
3635896132264Nonecode62Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 12" x 9" x 3" (300 x 228 x 76 mm) with all lead and lift and as directed by Engineer in charge of the workNos123.9123.99.0FalseNoneNoneFalseNoneFalse1115.10
3635897132264Nonecode63Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch with all lead and lift and as directed by Engineer in charge of the workNos676.14676.144.0FalseNoneNoneFalseNoneFalse2704.560
3635898132264Nonecode64Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch with all lead and lift and as directed by Engineer in charge of the workNos325.68325.6821.0FalseNoneNoneFalseNoneFalse6839.280
3635899132264Nonecode65Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point upto 3m from tapping point to out let via switch with all lead and lift and as directed by Engineer in charge of the workNos455.48455.4812.0FalseNoneNoneFalseNoneFalse5465.760
3635900132264Nonecode66Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6mf rom tapping point to out let via switch with all lead and lift and as directed by Engineer in charge of the workNos669.06669.066.0FalseNoneNoneFalseNoneFalse4014.360
3635901132264Nonecode67Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS-694:2010 4C x 2.5 mm2 with all lead and lift and as directed by Engineer in charge of the workRmtr166.38166.38300.0FalseNoneNoneFalseNoneFalse49914.00
3635902132264Nonecode68Supplying 6A flush/projected type socket and 6 amps flush/projected type SP switch either surface/flush mounting in a existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required. 6Amps 3/5 Way with all lead and lift and as directed by Engineer in charge of the workNos168.74168.7430.0FalseNoneNoneFalseNoneFalse5062.20
3635903132264Nonecode69Supplying 4mm thick plastic sheet with necessary nitches for fixing switches regulators etc., and fixing on existing wooden or metal box using N.F. screws. with all lead and lift and as directed by Engineer in charge of the workSq CM0.340.348000.0FalseNoneNoneFalseNoneFalse2720.00
3635904132264Nonecode70Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size 110 mm conduit using necessary machine screws. with all lead and lift and as directed by Engineer in charge of the workNos14.1614.168.0FalseNoneNoneFalseNoneFalse113.280
3635905132264Nonecode71Supplying & Fixing of 230 V 20/40 W Fluorescent Lamp holder with all lead and lift and as directed by Engineer in charge of the workNos20.0620.0614.0FalseNoneNoneFalseNoneFalse280.840
3635906132264Nonecode72Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. with all lead and lift and as directed by Engineer in charge of the workNos191.16191.164.0FalseNoneNoneFalseNoneFalse764.640
3635907132264Nonecode73Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP with all lead and lift and as directed by Engineer in charge of the workNos617.14617.144.0FalseNoneNoneFalseNoneFalse2468.560
3635908132264Nonecode74Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 8 Way SP & N with all lead and lift and as directed by Engineer in charge of the workNos1536.361536.364.0FalseNoneNoneFalseNoneFalse6145.440
3635909132264Nonecode75Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP with all lead and lift and as directed by Engineer in charge of the workNos1301.541301.542.0FalseNoneNoneFalseNoneFalse2603.080
3635910132264Nonecode76Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. with all lead and lift and as directed by Engineer in charge of the workNos4425.04425.02.0FalseNoneNoneFalseNoneFalse8850.00
3635911132264Nonecode77Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 300 mm x 214 mm with all lead and lift and as directed by Engineer in charge of the workNos4783.724783.722.0FalseNoneNoneFalseNoneFalse9567.440
3635912132264Nonecode78Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1500 mm Standard 40/50 mm dia with all lead and lift and as directed by Engineer in charge of the workNos2175.922175.926.0FalseNoneNoneFalseNoneFalse13055.520
3635913132264Nonecode79Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fxture with ........W System Power consumption. LED Effciencygreater than130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certifed agency & Design & Development facility certifed by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70 Watts with all lead and lift and as directed by Engineer in charge of the workNos7026.97026.95.0FalseNoneNoneFalseNoneFalse35134.50
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17221395840000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17221395840000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17221395840000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17221395840000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17221395840000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17221396080000NoneNoneELIGIBILITYA valid copy of registration certificate as Class-I & above Civil Registered Contractor of KPWD of state Government (License shall be within the validity period otherwise it will be rejected)None
17221396150000NoneNoneELIGIBILITYThe requisite Earnest Money Deposit in e-cashNone
17221396230000NoneNoneELIGIBILITYValid EPF and ESI Registration CertificateNone
17221396300000NoneNoneELIGIBILITYTechnical staff organization chartNone
17221396410000NoneNoneELIGIBILITYGST Certificate 1-The successful bidder shall furnish at the time of concluding the agreement within 15 days from issue of work order (1) Copy of Income Tax returns filed mentioning PAN and TAN for the financial year 2024-25 (Assessment year 2023-24) and (2) Copy of GST Registration Number/ Certificate, failing which the EMD amount will be forfeited and the contract will be rescinded at his risk and cost and liable for penal action including black listing. 2-The amount put to tender is inclusive of GST(rates are inclusive of 18% GST) and the tenderer should quote the rates including GST. The increase in GST shall not be paid in extended period of contract for which reasons for delay are attributable to the contractor as determined by the authority while granting the extension of time.None
17221396500000NoneNoneELIGIBILITYAs per order of Dept of Mines and Geology GoK vide letter No 2023-24 dt07-11-2023 it is mandatory for the contractor to produce Mineral Deposit Permit (MDP) before submitting the work bill for the quantities (Minerals) executed in the work. If not produced, necessary penalties will be levied as per above order.None
17221396590000NoneNoneELIGIBILITYDefect liability period will be 2 years from the completion of the work(After the issue of Completion Certificate)None
17222550810000NoneNoneELIGIBILITYThe PCC/RCC items, the rates are inclusive of formwork and exclusive of steel reinforcementNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneValid EPF and ESI Registration CertificatePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneValid EPF Certificate
NoneNoneNoneNoneThe intending bidder should have satisfactorily completed (90% of the contract value), as prime Contractor, at least one similar work of such as Road work of value not less than 50% of the amount put to tender, ie., Rs. 113.00 Lakhs during last 5 years reckoned back from 2023-24. The Certificate should be obtained from the officer not below the rank of Executive Engineer of the Concerned Division/Equivalent officer. The cost will be updated to the present value by giving weightage of 10% each year, If the work is completed prior to the year 2023-24. Note-Similar work means: Building work.Workdone Certificate to be uploaded should have following information:1)Date of Agreement Date 2)Agreement period in Months 3)Contract/ Agreement value Rs in Lakhs 4)Amount of work executed Rs in Lakhs 5)% of Fin. Progress w.r.t. Contract value 6)Date of completion of work The workdone certificate issued should have the countersignature of concerned Superintending EngineerPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe intending bidder should have executed a minimum quantity of following Items of work (Usually 80% of Peak annual rate of Construction in any one financial year, during the last five financial years reckoned back from 2023-24. Certificate should be obtained from an officer not below the rank of Executive Engineer of the concerned Division/Equivalent. Bidder should produce the work done certificates with yearwise breakup of quantity and it is mandatory. Earth work/Murrum 1755.00 m3 RCC/PCC 801.00 m3 TMT Steel 54.00 Masonry 294.00 m3 The workdone certificate issued should have the countersignature of concerned Superintending EngineerPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneA valid copy of registration certificate as Class-I & above Civil Registered Contractor of KPWD of state Government (License shall be within the validity period otherwise it will be rejected).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneTechnical staff organization chartPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Technical staff organization chart
NoneNoneNoneNoneThe bidder should have achieved a minimum financial turnover not less than Rs. 449.00 Lakhs (not less than two times the estimated amount ie., (Rs. 449.00 Lakhs) in at least two financial years during the last 5 years reckoned back from 2023-24 duly updating the financial turnover at 10% per annum. Audited profit and loss statement certified by a practicing Chartered Accountant along with copies of IT returns filed for the two years indicated above shall be furnished. C A CERTIFICATES SHALL BEAR THE UDI NUMBERCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneBID CAPACITY:The bidders who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available bid capacity is calculated as under:Assessed available Bid Capacity:(AxNx1.5-B) where A-Maximum value of Civil Engineering works executed in any one year during the last five years (Updated to 2024-25 price level) taking into account the completed as well as works in progress. N-Number of years ie.,0.50 year (06 months) prescribed for completion of works for which bids are invited.B-Value, at 2024-25 price level, of existing commitments and on-going works to be Completed during the next 0.50 year (period of completion of the works for which tenders are invited) Note-1 The statement showing the value of existing commitments and ongoing works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the employer in charge, not below the rank of Executive Engineer or equivalent. Note-2 Even though the bidders meet the above criteria, they are subject to be disqualified if they have: 1) Made misleading or false representations in the forms, statements and attachments submitted in proof of the qualification requirements, and/or 2) Record of poor performance such as abandoning the works, not properly completing the contract, inordinate delays in completion, litigation history, or financial failures etc, and/or 3) Participated in the previous tender for the same work and had quoted unreasonably high tender prices and could not furnish rational justification. 4) If the bidder/bidders have participated in more than one work, the available tender capacity will be assessed and number of works will be awarded as per his available bid capacityCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BID CAPACITY
NoneNoneNoneNoneDefect liability period will be 2 years from the completion of the work(After the issue of Completion Certificate)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- DLP
NoneNoneNoneNoneGST Certificate 1-The successful bidder shall furnish at the time of concluding the agreement within 15 days from issue of work order (1) Copy of Income Tax returns filed mentioning PAN and TAN for the financial year 2024-25 (Assessment year 2023-24) and (2) Copy of GST Registration Number/ Certificate, failing which the EMD amount will be forfeited and the contract will be rescinded at his risk and cost and liable for penal action including black listing. 2-The amount put to tender is inclusive of GST(rates are inclusive of 18% GST) and the tenderer should quote the rates including GST. The increase in GST shall not be paid in extended period of contract for which reasons for delay are attributable to the contractor as determined by the authority while granting the extension of timeCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneAs per order of Dept of Mines and Geology GoK vide letter No 2023-24 dt07-11-2023 it is mandatory for the contractor to produce Mineral Deposit Permit (MDP) before submitting the work bill for the quantities (Minerals) executed in the work. If not produced, necessary penalties will be levied as per above orderCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- MDP
NoneNoneNoneNoneThe requisite Earnest Money Deposit in e-cashFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- EMD
NoneNoneNoneNoneEach bidder should furnish liquid assets and or/availability of credit facilities not less than Rs.75.00 Lakhs (credit lines/letter of credit/certificate from the banks for meeting the fund requirement etc) (usually the equivalent of the estimated cash flow for 3 months in the peak construction period.)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
EPF RegistrationTrueTechnical Bid
ESI RegistrationTrueTechnical Bid
Work done CertificateTrueTechnical Bid
LOCTrueTechnical Bid
Bid CapacityTrueTechnical Bid
Quantities Executed CertificateTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsBagalkoteBilagiBagalkotBILGINearby BilagiNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1722255089000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of Executive Engineer UKP Reh Div No 3 Jamakhandi
streetNone
cityJamakhandi
stateKarnataka
pin587301
tenderRecallDTONone