createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1722092466895
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee4330.00
emd259000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose26-08-2024 17:30:00
tenderQueryClose21-08-2024 16:30:00
technicalBidOpen28-08-2024 11:00:00
publishedDate01-08-2024 11:11:25
publishedByPostUKPRR_EE_DIV3_JKD
publishedByUserKPE11247 - VISHWANATH G MIKKAL
bidValidityPeriod180
noOfCalls1
preBidMeetingDate23-08-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypePERCENTAGE
denominationTypeTextPercentage
retenderedYnNone
percentageRateTypeTextSingle Rate
contactPersonS B Shegunasi
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9164031043
tenderSupplierListNone
tenderSchedule
createdTs1722092466928
version4
createdDateNone
modifiedDateNone
tenderNumberUKPRR/2024-25/BD/WORK_INDENT24
titleConstruction of Shelter in Burial Ground at 1) Sonna RC, 2) Dhavaleshwar 3) Garadadinni 4)Heggur 5) Godihal 6) Korti 7) Bilagi Cross-III RCs and Construction of Crematorium in Burial Ground at 8) Sonna 9) Dhavaleshwar 10) Garadadinni 11) Heggur 12) Godihal 13) Korti 14) Bilagi Cross-III RCs and 15)Construction of Dhobi Ghat at Dhavaleshwar RC and 16)Construction of Agasi at Gundanapalle RC and 17)Construction of Pure Drinking Water Unit at Korti RC of Bilagi Tq of Bagalkot Dist (Package-8)
descriptionConstruction of Shelter in Burial Ground at 1) Sonna RC, 2) Dhavaleshwar RC, 3) Garadadinni RC, 4)Heggur (Bilagi Cross-I) RC, 5) Godihal (Bilagi Cross-I) RC , 6) Korti (Bilagi Cross-II) RC, 7) Bilagi Cross-III RC and Construction of Crematorium in Burial Ground at 8) Sonna RC, 9) Dhavaleshwar RC, 10) Garadadinni RC, 11) Heggur (Bilagi Cross-I) RC, 12) Godihal (Bilagi Cross-I) RC , 13) Korti (Bilagi Cross-II) RC, 14) Bilagi Cross-III RC and 15)Construction of Dhobi Ghat at Dhavaleshwar RC and 16)Construction of Agasi at Gundanapalle (Bilagi Cross-I) RC and 17)Construction of Pure Drinking Water Unit at Korti (Bilagi Cross-II) RC of Bilagi Tq of Bagalkot Dist (Package-8)
categoryWORKS
categoryTextWorks
ecv17300000.00
deptNameUpper Krishna Rehabilitation and Resettlement
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location5950
locationNameUKPRR Executive Engineer Office Div No 3 Jamkhandi
provisionalAmount17300000.0
groupOverheadTotal62837.57
fileNumberUKPRR/SD5/07
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17220924670000NoneNoneBuildingsConstruction of Shelter in Burial Ground at 1) Sonna RC, 2) Dhavaleshwar 3) Garadadinni 4)Heggur 5) Godihal 6) Korti 7) Bilagi Cross-III RCs and Construction of Crematorium in Burial Ground at 8) Sonna 9) Dhavaleshwar 10) Garadadinni 11) Heggur 12) Godihal 13) Korti 14) Bilagi Cross-III RCs and 15)Construction of Dhobi Ghat at Dhavaleshwar RC and 16)Construction of Agasi at Gundanapalle RC and 17)Construction of Pure Drinking Water Unit at Korti RC of Bilagi Tq of Bagalkot Dist (Package-8)17237162.43
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3635509132229Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work as per directions o with all lead and lift.Cum84.9684.96782.51FalseNoneNoneFalseNoneFalse66482.04960
3635510132229Nonecode02Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.(Without Roller Compaction) as per directions of Engineer-in-charge with all lead and lift.Cum450.64450.64922.19FalseNoneNoneFalseNoneFalse415575.70160
3635511132229Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates. as per directions of Engineer-in-charge with all lead and lift.Cum6143.086143.0871.7FalseNoneNoneFalseNoneFalse440458.8360
3635512132229Nonecode04Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) as per directions of Engineer-in-charge with all lead and lift.Cum5605.05605.0149.19FalseNoneNoneFalseNoneFalse836209.950
3635513132229Nonecode05Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work with all lead and liftCum7894.27894.2114.31FalseNoneNoneFalseNoneFalse902386.0020
3635514132229Nonecode06Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates as per directions of Engineer-in-charge with all lead and lift.Cum6759.046759.0481.13FalseNoneNoneFalseNoneFalse548360.91520
3635515132229Nonecode07Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. in foundation (Incl formwork and excluding cost of steel reinforcement) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per directions of Engineer-in-charge with all lead and lift.Cum7878.347878.3463.3FalseNoneNoneFalseNoneFalse498698.9220
3635516132229Nonecode08Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. in Columns (Incl formwork and excluding cost of steel reinforcement) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per directions of Engineer-in-charge with all lead and lift.Cum12401.0912401.0961.54FalseNoneNoneFalseNoneFalse763163.07860
3635517132229Nonecode09Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. in RCC walls/Beams (Incl formwork and excluding cost of steel reinforcement) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per directions of Engineer-in-charge with all lead and lift.Cum11671.6211671.62333.4FalseNoneNoneFalseNoneFalse3891318.1080
3635518132229Nonecode10Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) with all lead and lift as per directions of Engineer-in-charge with all lead and lift.Kgs108.56108.5641242.02FalseNoneNoneFalseNoneFalse4477233.69120
3635519132229Nonecode11Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. as per directions of Engineer-in-charge with all lead and lift.Sqm1420.721420.72627.18FalseNoneNoneFalseNoneFalse891047.16960
3635520132229Nonecode12Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding as per directions of Engineer-in-charge with all lead and lift.Kgs171.1171.18125.2FalseNoneNoneFalseNoneFalse1390221.720
3635521132229Nonecode13Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm251.34251.343240.06FalseNoneNoneFalseNoneFalse814356.68040
3635522132229Nonecode14Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm123.9123.9905.9FalseNoneNoneFalseNoneFalse112241.010
3635523132229Nonecode15Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge with all lead and lift.Sqm2961.82961.811.72FalseNoneNoneFalseNoneFalse34712.2960
3635524132229Nonecode16Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) with all lead and lift and as directed by Engineer in charge of the workSqm7564.987564.985.76FalseNoneNoneFalseNoneFalse43574.28480
3635525132229Nonecode17Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including costof materials, labour, usage charges of machinery complete as per specifications. as per directions of Engineer-in-charge with all lead and lift.Kgs423.62423.62128.0FalseNoneNoneFalseNoneFalse54223.360
3635526132229Nonecode18Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge with all lead and lift.Sqm941.64941.647.5FalseNoneNoneFalseNoneFalse7062.30
3635527132229Nonecode19Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm77.8877.882349.86FalseNoneNoneFalseNoneFalse183007.09680
3635528132229Nonecode20Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm106.2106.2528.72FalseNoneNoneFalseNoneFalse56150.0640
3635529132229Nonecode21Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.cm3.543.5412750.0FalseNoneNoneFalseNoneFalse45135.00
3635530132229Nonecode22Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications as per directions of Engineer-in-charge with all lead and lift.Sqm2789.522789.527.2FalseNoneNoneFalseNoneFalse20084.5440
3635531132229Nonecode23Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 600 x 300 x 150 mm Kerb Stone with all lead and lift and as directed by Engineer in charge of the workRmtr499.14499.1424.2FalseNoneNoneFalseNoneFalse12079.1880
3635532132229Nonecode24Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m as per directions of Engineer-in-charge with all lead and lift.Cum554.6554.668.85FalseNoneNoneFalseNoneFalse38184.210
3635533132229Nonecode25Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m with all lead and lift as per directions of Engineer-in-charge with all lead and lift and as directed by Engineer in charge of the workCum240.72240.7268.85FalseNoneNoneFalseNoneFalse16573.5720
3635534132229Nonecode26Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3 with all lead and lift as per directions of the Engineer-in-Charge.Rmtr312.23312.23170.0FalseNoneNoneFalseNoneFalse53079.10
3635535132229Nonecode27Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 80 mm dia GM (Copper alloy) Gate valves with all lead and lift as per directions of the Engineer-in-Charge.Nos2244.362244.364.0FalseNoneNoneFalseNoneFalse8977.440
3635536132229Nonecode28Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components For 1000 LPH FRP : Skid Type with all lead and lift as per directions of the Engineer-in-Charge.Nos537313.0537313.01.0FalseNoneNoneFalseNoneFalse537313.00
3635537132229Nonecode29Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 1000 litre capacity) Specification No.KBS 13.22 For 1000 Ltrs with all lead and lift as per directions of the Engineer-in-Charge.Nos8057.048057.042.0FalseNoneNoneFalseNoneFalse16114.080
3635538132229Nonecode30Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 56" Sweep (1400 mm) Regular model with all lead and lift as per directions of the Engineer-in-Charge.Nos2560.62560.61.0FalseNoneNoneFalseNoneFalse2560.60
3635539132229Nonecode31Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 15W, 6500K with all lead and lift as per directions of the Engineer-in-Charge.Nos397.66397.664.0FalseNoneNoneFalseNoneFalse1590.640
3635540132229Nonecode32Supplying heavy gauge PVC conduit pipe 25 mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. (25 mm dia 2 mm thick) as per directions of Engineer-in-charge.Rmtr82.682.630.0FalseNoneNoneFalseNoneFalse2478.00
3635541132229Nonecode33Supplying heavy gauge PVC Conduit Pipe 25mm dia 2 mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. as per directions of Engineer-in-charge.Rmtr94.494.412.0FalseNoneNoneFalseNoneFalse1132.80
3635542132229Nonecode34Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 12" x 9" x 3" (300 x 228 x 76 mm) with all lead and lift and as directed by Engineer in charge of the workNos123.9123.92.0FalseNoneNoneFalseNoneFalse247.80
3635543132229Nonecode35Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP with all lead and lift and as directed by Engineer in charge of the workNos676.14676.142.0FalseNoneNoneFalseNoneFalse1352.280
3635544132229Nonecode36Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch with all lead and lift and as directed by Engineer in charge of the workNos325.68325.683.0FalseNoneNoneFalseNoneFalse977.040
3635545132229Nonecode37Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point upto 3m from tapping point to out let via switch with all lead and lift and as directed by Engineer in charge of the workNos455.48455.482.0FalseNoneNoneFalseNoneFalse910.960
3635546132229Nonecode38Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6mf rom tapping point to out let via switch with all lead and lift and as directed by Engineer in charge of the workNos669.06669.062.0FalseNoneNoneFalseNoneFalse1338.120
3635547132229Nonecode39Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS-694:2010 4C x 2.5 mm2 with all lead and lift and as directed by Engineer in charge of the workRmtr166.38166.38100.0FalseNoneNoneFalseNoneFalse16638.00
3635548132229Nonecode40Supplying 6A flush/projected type socket and 6 amps flush/projected type SP switch either surface/flush mounting in a existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required. 6Amps 3/5 Way with all lead and lift and as directed by Engineer in charge of the workNos168.74168.745.0FalseNoneNoneFalseNoneFalse843.70
3635549132229Nonecode41Supplying 4mm thick plastic sheet with necessary nitches for fixing switches regulators etc., and fixing on existing wooden or metal box using N.F. screws. with all lead and lift and as directed by Engineer in charge of the workSq CM0.340.345000.0FalseNoneNoneFalseNoneFalse1700.00
3635550132229Nonecode42Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size 110 mm conduit using necessary machine screws. with all lead and lift and as directed by Engineer in charge of the workNos14.1614.162.0FalseNoneNoneFalseNoneFalse28.320
3635551132229Nonecode43Supplying & Fixing of 230 V 20/40 W Fluorescent Lamp holder with all lead and lift and as directed by Engineer in charge of the workNos20.0620.064.0FalseNoneNoneFalseNoneFalse80.240
3635552132229Nonecode44Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. with all lead and lift and as directed by Engineer in charge of the workNos191.16191.161.0FalseNoneNoneFalseNoneFalse191.160
3635553132229Nonecode45Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 8 Way SP & N with all lead and lift and as directed by Engineer in charge of the workNos1536.361536.361.0FalseNoneNoneFalseNoneFalse1536.360
3635554132229Nonecode46Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP with all lead and lift and as directed by Engineer in charge of the workNos617.14617.141.0FalseNoneNoneFalseNoneFalse617.140
3635555132229Nonecode47Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP with all lead and lift and as directed by Engineer in charge of the workNos1301.541301.541.0FalseNoneNoneFalseNoneFalse1301.540
3635556132229Nonecode48Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. with all lead and lift and as directed by Engineer in charge of the workNos4425.04425.01.0FalseNoneNoneFalseNoneFalse4425.00
3635557132229Nonecode49Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 300 mm x 214 mm with all lead and lift and as directed by Engineer in charge of the workNos4783.724783.721.0FalseNoneNoneFalseNoneFalse4783.720
3635558132229Nonecode50Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1500 mm Standard 40/50 mm dia with all lead and lift and as directed by Engineer in charge of the workNos2175.922175.922.0FalseNoneNoneFalseNoneFalse4351.840
3635559132229Nonecode51Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fxture with ..70.W System Power consumption. LED Effciency greater than130lm/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certifed agency & Design & Development facility certifed by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70 Watts with all lead and lift and as directed by Engineer in charge of the workNos7026.97026.92.0FalseNoneNoneFalseNoneFalse14053.80
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17220924680000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17220924680000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17220924680000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17220924680000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17220924680000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17220924790000NoneNoneELIGIBILITYA valid copy of registration certificate as Class-I & above Civil Registered Contractor of KPWD of state Government (License shall be within the validity period otherwise it will be rejected).None
17220924850000NoneNoneELIGIBILITYThe requisite Earnest Money Deposit in e-cashNone
17220924910000NoneNoneELIGIBILITYValid EPF and ESI Registration CertificateNone
17220925030000NoneNoneELIGIBILITYTechnical staff organization chartNone
17220925150000NoneNoneELIGIBILITYGST Certificate 1-The successful bidder shall furnish at the time of concluding the agreement within 15 days from issue of work order (1) Copy of Income Tax returns filed mentioning PAN and TAN for the financial year 2024-25 (Assessment year 2023-24) and (2) Copy of GST Registration Number/ Certificate, failing which the EMD amount will be forfeited and the contract will be rescinded at his risk and cost and liable for penal action including black listing. 2-The amount put to tender is inclusive of GST(rates are inclusive of 18% GST) and the tenderer should quote the rates including GST. The increase in GST shall not be paid in extended period of contract for which reasons for delay are attributable to the contractor as determined by the authority while granting the extension of time.None
17220925240000NoneNoneELIGIBILITYAs per order of Dept of Mines and Geology GoK vide letter No 2023-24 dt07-11-2023 it is mandatory for the contractor to produce Mineral Deposit Permit (MDP) before submitting the work bill for the quantities (Minerals) executed in the work. If not produced, necessary penalties will be levied as per above order.None
17220925310000NoneNoneELIGIBILITYDefect liability period will be 2 years from the completion of the work(After the issue of Completion Certificate)None
17222550270000NoneNoneELIGIBILITYThe PCC/RCC items, the rates are inclusive of formwork and exclusive of steel reinforcementNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneThe intending bidder should have satisfactorily completed (90% of the contract value), as prime Contractor, at least one similar work of such as Road work of value not less than 50% of the amount put to tender, ie., Rs. 87.00 Lakhs during last 5 years reckoned back from 2023-24. The Certificate should be obtained from the officer not below the rank of Executive Engineer of the Concerned Division/Equivalent officer. The cost will be updated to the present value by giving weightage of 10% each year, If the work is completed prior to the year 2023-24. Note-Similar work means: Building work.Workdone Certificate to be uploaded should have following information:1)Date of Agreement Date 2)Agreement period in Months 3)Contract/ Agreement value Rs in Lakhs 4)Amount of work executed Rs in Lakhs 5)% of Fin. Progress w.r.t. Contract value 6)Date of completion of work The workdone certificate issued should have the countersignature of concerned Superintending EngineerPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTechnical staff organization chartPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Technical staff organization chart
NoneNoneNoneNoneA valid copy of registration certificate as Class-I & above Civil Registered Contractor of KPWD of state Government (License shall be within the validity period otherwise it will be rejected).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneValid EPF and ESI Registration CertificatePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneValid EPF Certificate
NoneNoneNoneNoneThe intending bidder should have executed a minimum quantity of following Items of work (Usually 80% of Peak annual rate of Construction in any one financial year, during the last five financial years reckoned back from 2023-24. Certificate should be obtained from an officer not below the rank of Executive Engineer of the concerned Division/Equivalent. Bidder should produce the work done certificates with yearwise breakup of quantity and it is mandatory. Earth work/Murrum 1966.00 m3 RCC/PCC 652.00 m3 TMT Steel 46.00 Maonnry 282.00 m3 The workdone certificate issued should have the countersignature of concerned Superintending EngineerPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe bidder should have achieved a minimum financial turnover not less than Rs. 345.00 Lakhs (not less than two times the estimated amount ie., (Rs. 345.00 Lakhs) in at least two financial years during the last 5 years reckoned back from 2023-24 duly updating the financial turnover at 10% per annum. Audited profit and loss statement certified by a practicing Chartered Accountant along with copies of IT returns filed for the two years indicated above shall be furnished. C A CERTIFICATES SHALL BEAR THE UDI NUMBER.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneBID CAPACITY:The bidders who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available bid capacity is calculated as under:Assessed available Bid Capacity:(AxNx1.5-B) where A-Maximum value of Civil Engineering works executed in any one year during the last five years (Updated to 2024-25 price level) taking into account the completed as well as works in progress. N-Number of years ie.,0.50 year (06 months) prescribed for completion of works for which bids are invited.B-Value, at 2024-25 price level, of existing commitments and on-going works to be Completed during the next 0.50 year (period of completion of the works for which tenders are invited) Note-1 The statement showing the value of existing commitments and ongoing works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the employer in charge, not below the rank of Executive Engineer or equivalent. Note-2 Even though the bidders meet the above criteria, they are subject to be disqualified if they have: 1) Made misleading or false representations in the forms, statements and attachments submitted in proof of the qualification requirements, and/or 2) Record of poor performance such as abandoning the works, not properly completing the contract, inordinate delays in completion, litigation history, or financial failures etc, and/or 3) Participated in the previous tender for the same work and had quoted unreasonably high tender prices and could not furnish rational justification. 4) If the bidder/bidders have participated in more than one work, the available tender capacity will be assessed and number of works will be awarded as per his available bid capacityCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BID CAPACITY
NoneNoneNoneNoneAs per order of Dept of Mines and Geology GoK vide letter No 2023-24 dt07-11-2023 it is mandatory for the contractor to produce Mineral Deposit Permit (MDP) before submitting the work bill for the quantities (Minerals) executed in the work. If not produced, necessary penalties will be levied as per above order.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- MDP
NoneNoneNoneNoneDefect liability period will be 2 years from the completion of the work(After the issue of Completion Certificate)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- DLP
NoneNoneNoneNoneGST Certificate 1-The successful bidder shall furnish at the time of concluding the agreement within 15 days from issue of work order (1) Copy of Income Tax returns filed mentioning PAN and TAN for the financial year 2024-25 (Assessment year 2023-24) and (2) Copy of GST Registration Number/ Certificate, failing which the EMD amount will be forfeited and the contract will be rescinded at his risk and cost and liable for penal action including black listing. 2-The amount put to tender is inclusive of GST(rates are inclusive of 18% GST) and the tenderer should quote the rates including GST. The increase in GST shall not be paid in extended period of contract for which reasons for delay are attributable to the contractor as determined by the authority while granting the extension of timeCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneEach bidder should furnish liquid assets and or/availability of credit facilities not less than Rs.58.00 Lakhs (credit lines/letter of credit/certificate from the banks for meeting the fund requirement etc) (usually the equivalent of the estimated cash flow for 3 months in the peak construction period.)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneThe requisite Earnest Money Deposit in e-cashFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- EMD
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
EPF RegistrationTrueTechnical Bid
ESI RegistrationTrueTechnical Bid
Work done CertificateTrueTechnical Bid
LOCTrueTechnical Bid
Bid CapacityTrueTechnical Bid
Quantities Executed CertificateTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsBagalkoteBilagiBagalkotBILGINearby BilgiNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1722255036000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of Executive Engineer UKP Reh Div No 3 Jamakhandi
streetNone
cityJamakhandi
stateKarnataka
pin587301
tenderRecallDTONone