1722400904000 | 0 | None | None | Plants and Machinery | Construction of Drinking water Filter House at Budnahatty village Around School in Challakere Taluk (ST Catagory) | 803344.52 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3653301 | 133266 | None | Vol.I, 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3m (Volume-i) (P.No.8, I.No.1.14.1) PWD UNI SR 2023-24 | Cum | 102.0 | 102.0 | 13.4 | False | None | None | False | None | False | 1366.8 | 0 | 3653302 | 133266 | None | Vol.I, 2.1.2 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (Volume-i) (P.No.15, I.No.2.1.2) PWD UNI SR 2023-24 | Cum | 5664.0 | 5664.0 | 4.82 | False | None | None | False | None | False | 27300.48 | 0 | 3653303 | 133266 | None | Vol.II, 5.3 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Volume-2) (P.No.9, I.No.5.3) PWD UNI SR 2023-24 | Cum | 6205.0 | 6205.0 | 6.48 | False | None | None | False | None | False | 40208.4 | 0 | 3653304 | 133266 | None | Vol.II, 5.2 | Providing Coursed rubble masonry (first sort) with hard stone in foundation
and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Volume-2) (P.No.9, I.No.5.2) PWD UNI SR 2023-24 | Cum | 6618.0 | 6618.0 | 6.48 | False | None | None | False | None | False | 42884.64 | 0 | 3653305 | 133266 | None | Vol.I, 2.1.6 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (Volume-i) (P.No.15, I.No.2.1.6) PWD UNI SR 2023-24 | Cum | 6243.0 | 6243.0 | 7.66 | False | None | None | False | None | False | 47821.38 | 0 | 3653306 | 133266 | None | Vol.I, 6.33 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of achinery etc complete as per specifications (Volume-i) (P.No.17), I.No.6.33) PWD UNI SR 2023-24 | Sqm | 1231.0 | 1231.0 | 0.6 | False | None | None | False | None | False | 738.6 | 0 | 3653307 | 133266 | None | Vol.I, 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Volume-1) (P.No.7, I.No.1.9) PWD UNI SR 2023-24 | Cum | 266.0 | 266.0 | 13.4 | False | None | None | False | None | False | 3564.4 | 0 | 3653308 | 133266 | None | Vol.II, 9.17.2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm.Vol 2 (P.No.61.No. 9.17.2) PWD UNI SR 2023-24 | Sqm | 1175.0 | 1175.0 | 15.0 | False | None | None | False | None | False | 17625.0 | 0 | 3653309 | 133266 | None | Vol.II, 8.19.1 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, ncluding cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.(Volume-2) (P.No.44, I.No.8.19.1) PWD UNI SR 2023-24 | Sqm | 255.0 | 255.0 | 11.71 | False | None | None | False | None | False | 2986.05 | 0 | 3653310 | 133266 | None | Vol.I, 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Volume-1) (P.No.16, I.No.2.5.1) PWD UNI SR 2023-24 | Cum | 10608.0 | 10608.0 | 3.22 | False | None | None | False | None | False | 34157.76 | 0 | 3653311 | 133266 | None | Vol.II, 11.44 | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Volume-2) (P.No. 91, I.No.11.44) PWD UNI SR 2023-24 | Sqm | 4345.0 | 4345.0 | 4.32 | False | None | None | False | None | False | 18770.4 | 0 | 3653312 | 133266 | None | Vol.III, 21 c(3) | Providing Vertical Delineator having wide angle cube corner micro prismatic non metallic reflective sheeting confirming to Type XI of ASTM D4956 -09 with White Color and Red Color combination and having minimum of retro reflective exposed area of 125 Sq CM on top slots and 35 cm2 on bottom slots and no edges shall be exposed for tampering. This tubu lar delineator shall have a core and shell construction, shell shall be made of tough, high impact resistant, injection-molded, thermoplastic outer body and the inner core shall consist of powder coated or painted Mild steel of minimum thickness 1.0mm.and coreshell structure shall be of height not less than 800 mm above the ground and width not less than 80 mm. The metallic core of the delineator shall extend 300mm beyond the shell length from bottom for installing in the ground. The extended portion shall have slots to insert anchoring rods for enhancing the concrete grip. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The engineering thermoplastic used for making the delineator body shall have minimum initial mechanical properties of be fixed by a combination of epoxy adhesive and grouting as per MoRTH specification 806 . (Volume-3) (P.No. 151, I.No.21-c(3)) PWD UNI SR 2023-24 | Nos | 2900.0 | 2900.0 | 1.0 | False | None | None | False | None | False | 2900.0 | 0 | 3653313 | 133266 | None | Vol. II.11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Volume-2) (P.No.82, I.No.11.16.2) PWD UNI SR 2023-24 | Kg | 147.0 | 147.0 | 750.62 | False | None | None | False | None | False | 110341.14 | 0 | 3653314 | 133266 | None | Vol.II, 7.58 | Providing and Fixing in position Acoustical wall panelling with Integral Densified Square/Butt edged Fully Perforated Eco Friendly Light weight Calcium Silicate panels/tiles with fabricated galvanised mild steel frame work for Auditoriums, Community halls, Offices, Institutions, Airports,Meeting halls, Indoor Stadiums and Studios. The Eco Friendly Light weight Calcium Silicate wall panels/tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesnt contain any toxic ingrediants. The wall panels/tiles size of 595x595mm and 15mm thick should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performace A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC (NoiseReductions Coefficient) 0.65 to 0.85The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fibre joint tape roll 50mm wide (90metre) roll and two coats of premier suitable for panelling as per manfacturer's specification as per direction of Engineer-in-charge all complete (Volume-2) (P.No. 35, I.No.7.58) PWD UNI SR 2023-24 | Sqm | 2925.0 | 2925.0 | 25.92 | False | None | None | False | None | False | 75816.0 | 0 | 3653315 | 133266 | None | Vol.II, 11.35.1.1 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge.(Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications (Volume-2) (P.No. 88, I.No.11.35.1.1) PWD UNI SR 2023-24 | Kg | 452.0 | 452.0 | 70.0 | False | None | None | False | None | False | 31640.0 | 0 | 3653316 | 133266 | None | Vol.II, 11.37.2 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. . (Volume-2) (P.No. 89, I.No.11.37.2) PWD UNI SR 2023-24 | Sqm | 1171.0 | 1171.0 | 3.87 | False | None | None | False | None | False | 4531.77 | 0 | 3653317 | 133266 | None | Vol.II, 11.42.1 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete: Upto 5mm depth and 5 mm width including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Volume-2) (P.No. 91, I.No.11.42.1) PWD UNI SR 2023-24 | Rmtr | 62.0 | 62.0 | 30.3 | False | None | None | False | None | False | 1878.6 | 0 | 3653318 | 133266 | None | Vol.v, 21.1.8 | Water purification plants Supplying Installation and Commissioning of automatic Water purification plant (RO UF) with all accessories piping product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material loading and unloading and as directed by the Engineer in charge. Ref detailed specification enclosed seperatly). Note 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BS 1 NES standards, with BSI NES mark .3. Tenders to be invited for procurement. 4. No direct payment should be made under any situat on or condition or on any account. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge Note Refer the ANNEXURE : F for Detailed Specification of Each components ( CSR-2023-24 Vol V Page No 247.SOR YO10H Item No 21.1.8 | Each | 307000.0 | 307000.0 | 1.0 | False | None | None | False | None | False | 307000.0 | 0 | 3653319 | 133266 | None | Eltrcl, 1.1.2 | Open Conduit System Supplying heavy gauge PVC conduit pipe . dia . mm
thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick (P.NO. 2-105, I.NO.1.1.2 ) PWD Electrical SR 2023-24" | Mtr | 81.0 | 81.0 | 40.0 | False | None | None | False | None | False | 3240.0 | 0 | 3653320 | 133266 | None | Eltrcl, 1.6.4 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 8"x6"x3" (203x152x76mm) (P.NO. 3-105, I.NO.1.6.4 ) PWD Electrical SR 2023-24 | Each | 86.0 | 86.0 | 6.0 | False | None | None | False | None | False | 516.0 | 0 | 3653321 | 133266 | None | Eltrcl, 2.1 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (P.NO. 5-105, I.NO.2.1) PWD Electrical SR 2023-24 2.1.1 Point wiring using class A Materialsa) Short point up to 3Mtr from tapping point to out let via switch
| Each Point | 285.0 | 285.0 | 1.0 | False | None | None | False | None | False | 285.0 | 0 | 3653322 | 133266 | None | Eltrcl, 2.1 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (P.NO. 5-105, I.NO.2.1) PWD Electrical SR 2023-24 2.1.2 Point wiring using class A Materials b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Each Point | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | 3653323 | 133266 | None | Eltrcl, 2.1 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (P.NO. 5-105, I.NO.2.1) PWD Electrical SR 2023-24 2.1.3 Point wiring using class A Materials c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch
| Each Point | 570.0 | 570.0 | 4.0 | False | None | None | False | None | False | 2280.0 | 0 | 3653324 | 133266 | None | Eltrcl, 3.1.2 | Supplying 6A flush/projected type socket and 6 amps flush/projected type SP switch either surface/flush mounting in a existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required. b) 6Amps 3/5 Way (P.NO. 8-105, I.NO.3.1.2) PWD Electrical SR 2023-24 | Each | 147.0 | 147.0 | 2.0 | False | None | None | False | None | False | 294.0 | 0 | 3653325 | 133266 | None | Eltrcl, 3.3.2 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 Way (P.NO. 8-105, I.NO.3.3.2)PWD Electrical SR 2023-24 | Each | 124.0 | 124.0 | 2.0 | False | None | None | False | None | False | 248.0 | 0 | 3653326 | 133266 | None | Eltrcl, 3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way (P.NO. 8-105, I.NO.3.3.3) PWD Electrical SR 2023-24 | Each | 137.0 | 137.0 | 2.0 | False | None | None | False | None | False | 274.0 | 0 | 3653327 | 133266 | None | Eltrcl, 2.3.2, 2.3.3, 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (P.NO. 5-105, I.No. 2.3.2, 2.3.3 &2.3.5)PWD Electrical SR 2023-24 2.3.2 1.5 sqmm (Copper wire) | Mtr | 26.0 | 26.0 | 70.0 | False | None | None | False | None | False | 1820.0 | 0 | 3653328 | 133266 | None | Eltrcl, 2.3.2, 2.3.3, 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (P.NO. 5-105, I.No. 2.3.2, 2.3.3 &2.3.5)PWD Electrical SR 2023-24 2.3.3 2.5 sqmm (Copper wire)
| Mtr | 42.0 | 42.0 | 30.0 | False | None | None | False | None | False | 1260.0 | 0 | 3653329 | 133266 | None | Eltrcl, 2.3.2, 2.3.3, 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (P.NO. 5-105, I.No. 2.3.2, 2.3.3 &2.3.5)PWD Electrical SR 2023-24 2.3.5 6 sqmm (Copper wire)
| Mtr | 92.0 | 92.0 | 60.0 | False | None | None | False | None | False | 5520.0 | 0 | 3653330 | 133266 | None | Eltrcl, 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches regulators etc., and fixing on existing wooden or metal box using N.F. screws. (P.NO. 9-105, I.No. 3.8) PWD Electrical SR 2023-24 | Sq CM | 0.41 | 0.41 | 1500.0 | False | None | None | False | None | False | 615.0 | 0 | 3653331 | 133266 | None | Eltrcl, 11.3.2 | Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70% lumen maintenance with CRI 80. Power Input 220-240V at 50 60Hz and Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fighting 1 x4'- 20/22 w (P.NO. 43-105, I.NO.11.3.2 ) PWD Electrical SR 2022-23 | Each | 690.0 | 690.0 | 4.0 | False | None | None | False | None | False | 2760.0 | 0 | 3653332 | 133266 | None | Eltrcl, 13.1.1 | SupplyingandFixingof.mmdiaclassAGIpipebracketupto2mslongbentatsuitableangleandfixingtothisbracketstreetlightfittingofallcapacitiestoGIorGIorrailorRCpole/wallusingsuitableclamps,bolts,andnutsandwiringusingsuitablecapacitywires. Using 25mm dia G.I.Pipe (P.NO. 56-105, I.NO.13.1.1) PWD Electrical SR 2022-23 | Each | 978.0 | 978.0 | 2.0 | False | None | None | False | None | False | 1956.0 | 0 | 3653333 | 133266 | None | Eltrcl, 5.6.6 | Supply and fixing polished wood board made of not less than15 mm thick plank on both sides of not morethan 2 piece sand fixing the same to the wall using tap red inverted wooden plugs screws. (P.NO.14 105, I.NO.5.6.6) PWD Electrical SR 2022 23 | Each | 326.13 | 326.13 | 2.0 | False | None | None | False | None | False | 652.26 | 0 | 3653334 | 133266 | None | Eltrcl, 6.7.2 | Supplying and fixing of Porcelain fuse channel with cutout on existing wooden/panel using necessary nuts, bolts and washers 32 A (P.NO. 14105, I.NO.6.7.2) PWD Electrical SR 2022-23 | Each | 241.0 | 241.0 | 2.0 | False | None | None | False | None | False | 482.0 | 0 | 3653335 | 133266 | None | Eltrcl, 5.7.2 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. (P.NO. 17-105, I.NO.5.7.2 ) PWD Electrical SR 2022-23 5.18.4 6-32 A DP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 | 3653336 | 133266 | None | Eltrcl, 5.7.2 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. (P.NO. 17-105, I.NO.5.7.2 ) PWD Electrical SR 2022-23 5.18.3 50-63 A SP
| Each | 811.0 | 811.0 | 4.0 | False | None | None | False | None | False | 3244.0 | 0 | 3653337 | 133266 | None | Eltrcl, 6.28 | Supplying, fixing and wiring electronic 5 to 20Amps SIngle phase Class-1 Accuracy Energy Meter. Group A (P.No.48, I.No.6.28) | Each | 1188.0 | 1188.0 | 1.0 | False | None | None | False | None | False | 1188.0 | 0 | 3653338 | 133266 | None | Eltrcl,12.56 | Supplying,fixing,wiring,earthelectrodeforgroundingconduits,I.C.cutoutsandotherequipment'sonthemeterboardusing40mmdia2.90mmthickGIpipe2.5mlongburiedinapit.Thepitshouldbefilledwithequalproportionofsaltandcharcoal150mmall-undthepipetocompletedepth .Theconnectionfromthepipetothe conduitetc., istobeestablishedthroughGIwireofsizeasperlSIspecification7.3.3.ofIS732using12mmdiabolts,nuts,washersandchecknutsetc., the pipe shall have 16 through holes of 12 mm dia (P.No.54, I.No.12.56) PWD Electrical SR 2022-23 | Rmtr | 3510.0 | 3510.0 | 1.0 | False | None | None | False | None | False | 3510.0 | 0 | 3653339 | 133266 | None | Eltrcl,32.05 | Supplying of LT UG cable having aluminium conductor PVC insulated, sheathed, galvanised, steel wire/steel tap armoured cable with PVC outer sheathing 1.1 KV class. Class A’ PVC Cable 4 core 16 sqmm (P.No.55, I.No.32.05) | Each | 141.84 | 141.84 | 1.0 | False | None | None | False | None | False | 141.84 | 0 |
|