1722332830000 | 0 | None | None | Buildings | CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT NIDLAGHATTA IN MADDUR TALUKA OF MANDYA DISTRICT. (Civil Works) | 5775452.25 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3645642 | 132901 | None | V-3 P-9 I-2.5iia | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. | 100 Sqm | 463.74 | 463.74 | 7.5 | False | None | None | False | None | False | 3478.05 | 0 | 3645643 | 132901 | None | V-1 P-8 I-1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 112.1 | 112.1 | 75.0 | False | None | None | False | None | False | 8407.5 | 0 | 3645644 | 132901 | None | V-1 P-8 I-1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 120.36 | 120.36 | 221.3 | False | None | None | False | None | False | 26635.668 | 0 | 3645645 | 132901 | None | V-1 P-8 I-4.1 | Providing and injecting chemical emulsion for Pre-constructional
Anti-Termite Treatment, creating continuous chemical barrier under
and around the column pits, walls, trenches, basement excavation, top
surface of the plinth filling, junction of wall and floor, along the external
perimeter of building, expansion joints, over the top surface of consolidated
earth on which apron is to be laid, surrounding of pipes and conduits with
Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of
chemical, diluting in water to one percent concentration, labour, usage
charges of machinery, complete as per specifications | Sqm | 139.24 | 139.24 | 10.42 | False | None | None | False | None | False | 1450.8808 | 0 | 3645646 | 132901 | None | V-1 P-15 I-2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. --- Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7067.02 | 7067.02 | 29.11 | False | None | None | False | None | False | 205720.9522 | 0 | 3645647 | 132901 | None | V-1 P-15 I-2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) --- M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7418.66 | 7418.66 | 37.57 | False | None | None | False | None | False | 278719.0562 | 0 | 3645648 | 132901 | None | V-1 P-7 I-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 0cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 313.88 | 313.88 | 177.04 | False | None | None | False | None | False | 55569.3152 | 0 | 3645649 | 132901 | None | V-1 P-7 I-1.87 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 559.32 | 559.32 | 194.02 | False | None | None | False | None | False | 108519.2664 | 0 | 3645650 | 132901 | None | V-2 P-9 I-5.1.1 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6620.98 | 6620.98 | 7.2 | False | None | None | False | None | False | 47671.056 | 0 | 3645651 | 132901 | None | V-2 P-9 I-5.3 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 7321.9 | 7321.9 | 5.4 | False | None | None | False | None | False | 39538.26 | 0 | 3645652 | 132901 | None | V-1 P-16 I-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GF | Cum | 8074.74 | 8074.74 | 44.67 | False | None | None | False | None | False | 360698.6358 | 0 | 3645653 | 132901 | None | V-1 P-16 I-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FF | Cum | 8155.49 | 8155.49 | 20.89 | False | None | None | False | None | False | 170368.1861 | 0 | 3645654 | 132901 | None | V-1 P-111 | Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Footings, Pedestal | Cum | 593.49 | 593.49 | 29.44 | False | None | None | False | None | False | 17472.3456 | 0 | 3645655 | 132901 | None | V-1 P-111 | Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS GF | Cum | 5652.32 | 5652.32 | 9.18 | False | None | None | False | None | False | 51888.2976 | 0 | 3645656 | 132901 | None | V-1 P-111 | Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. COLUMNS FF | Cum | 5708.84 | 5708.84 | 3.47 | False | None | None | False | None | False | 19809.6748 | 0 | 3645657 | 132901 | None | V-1 P-111 | Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. PLINTH BEAM | Cum | 4037.37 | 4037.37 | 8.86 | False | None | None | False | None | False | 35771.0982 | 0 | 3645658 | 132901 | None | V-1 P-111 | Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM GF | Cum | 4844.84 | 4844.84 | 12.29 | False | None | None | False | None | False | 59543.0836 | 0 | 3645659 | 132901 | None | V-1 P-111 | Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. LINTELS, ROOF BEAM FF | Cum | 4893.29 | 4893.29 | 5.85 | False | None | None | False | None | False | 28625.7465 | 0 | 3645660 | 132901 | None | V-1 P-111 | Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB GF | Cum | 4037.37 | 4037.37 | 14.08 | False | None | None | False | None | False | 56846.1696 | 0 | 3645661 | 132901 | None | V-1 P-111 | Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. ROOF SLAB FF | Cum | 4077.74 | 4077.74 | 18.49 | False | None | None | False | None | False | 75397.4126 | 0 | 3645662 | 132901 | None | V-1 P-111 | Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja GF | Cum | 3633.63 | 3633.63 | 1.03 | False | None | None | False | None | False | 3742.6389 | 0 | 3645663 | 132901 | None | V-1 P-111 | Appendix I-Additionalities for Formwork, Centering & Scaffolding ---- Including cost of all materials, labours, HOM, I & UL, Curing with all lead and lifts etc. complete as per specifications and as directed by engineer-in-charge of the work. Chajja FF | Cum | 3669.97 | 3669.97 | 0.26 | False | None | None | False | None | False | 954.1922 | 0 | 3645664 | 132901 | None | V-1 P-15 I-2.1.6 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates GF | Cum | 7366.74 | 7366.74 | 4.12 | False | None | None | False | None | False | 30350.9688 | 0 | 3645665 | 132901 | None | V-1 P-15 I-2.1.6 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates FF | Cum | 7440.41 | 7440.41 | 1.69 | False | None | None | False | None | False | 12574.2929 | 0 | 3645666 | 132901 | None | V-1 P-18 I-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification. GF | Tonne | 105559.26 | 105559.26 | 8.55 | False | None | None | False | None | False | 902531.673 | 0 | 3645667 | 132901 | None | V-1 P-18 I-2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and
technical specification. FF | Tonne | 106614.85 | 106614.85 | 2.56 | False | None | None | False | None | False | 272934.016 | 0 | 3645668 | 132901 | None | V-2 P-14 I-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GF | Cum | 9403.42 | 9403.42 | 37.38 | False | None | None | False | None | False | 351499.8396 | 0 | 3645669 | 132901 | None | V-2 P-14 I-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FF | Cum | 9497.45 | 9497.45 | 22.8 | False | None | None | False | None | False | 216541.86 | 0 | 3645670 | 132901 | None | V-2 P-14 I-6.13 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GF | Sqm | 1151.68 | 1151.68 | 35.55 | False | None | None | False | None | False | 40942.224 | 0 | 3645671 | 132901 | None | V-2 P-14 I-6.13 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. FF | Sqm | 1163.2 | 1163.2 | 45.11 | False | None | None | False | None | False | 52471.952 | 0 | 3645672 | 132901 | None | V-2 P-100 I-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. GF | Cum | 116601.7 | 116601.7 | 0.45 | False | None | None | False | None | False | 52470.765 | 0 | 3645673 | 132901 | None | V-2 P-100 I-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. FF | Cum | 117767.72 | 117767.72 | 0.45 | False | None | None | False | None | False | 52995.474 | 0 | 3645674 | 132901 | None | V-2 P-104 I-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GF | Nos | 1198.88 | 1198.88 | 4.0 | False | None | None | False | None | False | 4795.52 | 0 | 3645675 | 132901 | None | V-2 P-104 I-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FF | Nos | 1210.87 | 1210.87 | 4.0 | False | None | None | False | None | False | 4843.48 | 0 | 3645676 | 132901 | None | V-2 P-219 I-22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm GF | Each | 442.5 | 442.5 | 4.0 | False | None | None | False | None | False | 1770.0 | 0 | 3645677 | 132901 | None | V-2 P-219 I-22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Aldrop 16mm dia, 300mm FF | Each | 446.93 | 446.93 | 4.0 | False | None | None | False | None | False | 1787.72 | 0 | 3645678 | 132901 | None | V-2 P-219 I-22.15.1 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm GF | Each | 531.0 | 531.0 | 8.0 | False | None | None | False | None | False | 4248.0 | 0 | 3645679 | 132901 | None | V-2 P-219 I-22.15.1 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Handles 200mm FF | Each | 536.31 | 536.31 | 8.0 | False | None | None | False | None | False | 4290.48 | 0 | 3645680 | 132901 | None | V-2 P-219 I-22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm GF | Each | 177.0 | 177.0 | 4.0 | False | None | None | False | None | False | 708.0 | 0 | 3645681 | 132901 | None | V-2 P-219 I-22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS Tower Bolts 200x10mm FF | Each | 178.77 | 178.77 | 4.0 | False | None | None | False | None | False | 715.08 | 0 | 3645682 | 132901 | None | V-2 P-219 I-22.15.8 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm GF | Each | 59.0 | 59.0 | 16.0 | False | None | None | False | None | False | 944.0 | 0 | 3645683 | 132901 | None | V-2 P-219 I-22.15.8 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge ---- SS hinges 125 mm FF | Each | 59.59 | 59.59 | 16.0 | False | None | None | False | None | False | 953.44 | 0 | 3645684 | 132901 | None | V-2 P-69 I-10.6.2 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GF | Each | 64.9 | 64.9 | 12.0 | False | None | None | False | None | False | 778.8 | 0 | 3645685 | 132901 | None | V-2 P-69 I-10.6.2 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FF | Each | 65.55 | 65.55 | 12.0 | False | None | None | False | None | False | 786.6 | 0 | 3645686 | 132901 | None | V-2 P-205 I-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GF | Mtr | 61.36 | 61.36 | 24.0 | False | None | None | False | None | False | 1472.64 | 0 | 3645687 | 132901 | None | V-2 P-205 I-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. FF | Mtr | 61.97 | 61.97 | 24.0 | False | None | None | False | None | False | 1487.28 | 0 | 3645688 | 132901 | None | V-2 P-105 I-12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial GF | Sqm | 3919.96 | 3919.96 | 15.36 | False | None | None | False | None | False | 60210.5856 | 0 | 3645689 | 132901 | None | V-2 P-105 I-12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial FF | Sqm | 3959.16 | 3959.16 | 15.36 | False | None | None | False | None | False | 60812.6976 | 0 | 3645690 | 132901 | None | V-2 P-110 I-12.89 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GF | Sqm | 7730.18 | 7730.18 | 9.84 | False | None | None | False | None | False | 76064.9712 | 0 | 3645691 | 132901 | None | V-2 P-110 I-12.89 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FF | Sqm | 7807.48 | 7807.48 | 9.6 | False | None | None | False | None | False | 74951.808 | 0 | 3645692 | 132901 | None | V-2 P-109 I-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GF | Sqm | 6748.42 | 6748.42 | 0.72 | False | None | None | False | None | False | 4858.8624 | 0 | 3645693 | 132901 | None | V-2 P-109 I-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FF | Sqm | 6815.9 | 6815.9 | 0.72 | False | None | None | False | None | False | 4907.448 | 0 | 3645694 | 132901 | None | V-2 P-85 I-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GF | Kgs | 198.24 | 198.24 | 206.64 | False | None | None | False | None | False | 40964.3136 | 0 | 3645695 | 132901 | None | V-2 P-85 I-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FF | Kgs | 200.22 | 200.22 | 206.64 | False | None | None | False | None | False | 41373.4608 | 0 | 3645696 | 132901 | None | V-2 P-111 I-12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm GF | Mtr | 828.36 | 828.36 | 9.8 | False | None | None | False | None | False | 8117.928 | 0 | 3645697 | 132901 | None | V-2 P-111 I-12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) --- Size 62 x 100mm FF | Mtr | 836.64 | 836.64 | 9.8 | False | None | None | False | None | False | 8199.072 | 0 | 3645698 | 132901 | None | V-2 P-112 I-12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness GF | Sqm | 4112.3 | 4112.3 | 3.15 | False | None | None | False | None | False | 12953.745 | 0 | 3645699 | 132901 | None | V-2 P-112 I-12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) - 30 mm thickness FF | Sqm | 4153.42 | 4153.42 | 3.15 | False | None | None | False | None | False | 13083.273 | 0 | 3645700 | 132901 | None | V-2 P-42 I-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GF | Sqm | 411.82 | 411.82 | 241.84 | False | None | None | False | None | False | 99594.5488 | 0 | 3645701 | 132901 | None | V-2 P-42 I-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FF | Sqm | 415.94 | 415.94 | 141.19 | False | None | None | False | None | False | 58726.5686 | 0 | 3645702 | 132901 | None | V-2 P-43 I-8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GF | Sqm | 248.98 | 248.98 | 93.2 | False | None | None | False | None | False | 23204.936 | 0 | 3645703 | 132901 | None | V-2 P-43 I-8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FF | Sqm | 251.47 | 251.47 | 72.81 | False | None | None | False | None | False | 18309.5307 | 0 | 3645704 | 132901 | None | V-2 P-50 I-8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GF | Sqm | 118.0 | 118.0 | 335.04 | False | None | None | False | None | False | 39534.72 | 0 | 3645705 | 132901 | None | V-2 P-50 I-8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FF | Sqm | 119.18 | 119.18 | 214.0 | False | None | None | False | None | False | 25504.52 | 0 | 3645706 | 132901 | None | V-2 P-42 I-8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) GF | Sqm | 437.78 | 437.78 | 163.75 | False | None | None | False | None | False | 71686.475 | 0 | 3645707 | 132901 | None | V-2 P-42 I-8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (outside) FF | Sqm | 442.16 | 442.16 | 146.23 | False | None | None | False | None | False | 64657.0568 | 0 | 3645708 | 132901 | None | V-2 P-43 I-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment GF | Mtr | 40.12 | 40.12 | 676.2 | False | None | None | False | None | False | 27129.144 | 0 | 3645709 | 132901 | None | V-2 P-43 I-8.16.1 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment FF | Mtr | 40.52 | 40.52 | 676.2 | False | None | None | False | None | False | 27399.624 | 0 | 3645710 | 132901 | None | V-2 P-54 I-8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. GF | Mtr | 61.36 | 61.36 | 271.01 | False | None | None | False | None | False | 16629.1736 | 0 | 3645711 | 132901 | None | V-2 P-54 I-8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. FF | Mtr | 61.97 | 61.97 | 271.01 | False | None | None | False | None | False | 16794.4897 | 0 | 3645712 | 132901 | None | V-2 P-60 I-9.12.2 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm GF | Sqm | 1351.1 | 1351.1 | 56.4 | False | None | None | False | None | False | 76202.04 | 0 | 3645713 | 132901 | None | V-2 P-60 I-9.12.2 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm FF | Sqm | 1364.61 | 1364.61 | 52.46 | False | None | None | False | None | False | 71587.4406 | 0 | 3645714 | 132901 | None | V-2 P-40 I-8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GF | Sqm | 329.22 | 329.22 | 67.22 | False | None | None | False | None | False | 22130.1684 | 0 | 3645715 | 132901 | None | V-2 P-40 I-8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FF | Sqm | 332.51 | 332.51 | 67.22 | False | None | None | False | None | False | 22351.3222 | 0 | 3645716 | 132901 | None | V-2 P-60 I-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. GF | Sqm | 1049.02 | 1049.02 | 5.98 | False | None | None | False | None | False | 6273.1396 | 0 | 3645717 | 132901 | None | V-2 P-60 I-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. FF | Sqm | 1059.51 | 1059.51 | 5.98 | False | None | None | False | None | False | 6335.8698 | 0 | 3645718 | 132901 | None | V-2 P-64 I-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GF | Sqm | 1709.82 | 1709.82 | 67.22 | False | None | None | False | None | False | 114934.1004 | 0 | 3645719 | 132901 | None | V-2 P-64 I-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FF | Sqm | 1726.92 | 1726.92 | 6.3 | False | None | None | False | None | False | 10879.596 | 0 | 3645720 | 132901 | None | V-2 P-48 I-8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF | Sqm | 149.86 | 149.86 | 335.04 | False | None | None | False | None | False | 50209.0944 | 0 | 3645721 | 132901 | None | V-2 P-48 I-8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FF | Sqm | 151.36 | 151.36 | 214.0 | False | None | None | False | None | False | 32391.04 | 0 | 3645722 | 132901 | None | V-2 P-46 I-8.31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF | Sqm | 210.04 | 210.04 | 163.75 | False | None | None | False | None | False | 34394.05 | 0 | 3645723 | 132901 | None | V-2 P-46 I-8.31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FF | Sqm | 212.14 | 212.14 | 146.23 | False | None | None | False | None | False | 31021.2322 | 0 | 3645724 | 132901 | None | V-2 P-48 I-8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF | Sqm | 135.7 | 135.7 | 62.22 | False | None | None | False | None | False | 8443.254 | 0 | 3645725 | 132901 | None | V-2 P-48 I-8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FF | Sqm | 137.06 | 137.06 | 62.22 | False | None | None | False | None | False | 8527.8732 | 0 | 3645726 | 132901 | None | V-2 P-48 I-8.38 | Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF | Sqm | 47.2 | 47.2 | 25.2 | False | None | None | False | None | False | 1189.44 | 0 | 3645727 | 132901 | None | V-2 P-48 I-8.38 | Painting with oil type wood preservative of approved brand and manufacture :New work (two coats) to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FF | Sqm | 47.67 | 47.67 | 25.2 | False | None | None | False | None | False | 1201.284 | 0 | 3645728 | 132901 | None | V-2 P-63 I-9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. GF | Sqm | 3365.36 | 3365.36 | 51.69 | False | None | None | False | None | False | 173955.4584 | 0 | 3645729 | 132901 | None | V-2 P-63 I-9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. FF | Sqm | 3399.01 | 3399.01 | 13.5 | False | None | None | False | None | False | 45886.635 | 0 | 3645730 | 132901 | None | V-2 P-85 I-11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GF | Kgs | 666.7 | 666.7 | 288.0 | False | None | None | False | None | False | 192009.6 | 0 | 3645731 | 132901 | None | V-2 P-85 I-11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FF | Kgs | 673.37 | 673.37 | 119.07 | False | None | None | False | None | False | 80178.1659 | 0 | 3645732 | 132901 | None | V-2 P-87 I-11.35.1.1 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. GF | Kgs | 533.36 | 533.36 | 88.2 | False | None | None | False | None | False | 47042.352 | 0 | 3645733 | 132901 | None | Item | The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration and providing consultancy for Architectural designs & drawings, elevation, 3D view, Internal and External Electrical services including electrical infrastructure , Lifts, CCTV/Net working system interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. ---- ---- --- ---- etc., complete with all lead and lift as per detailed specification and directions of the Engineer incharge | LS | 47200.0 | 47200.0 | 1.0 | False | None | None | False | None | False | 47200.0 | 0 | 3645734 | 132901 | None | V-2 P-84 I-11.25.2 | Providing and fixing Steel work welded in built up sections/ framed
work, including cutting, hoisting, fixing in position and applying a priming
coat of approved steel primer using structural steel etc. as required. In
gratings, frames, guard bar, ladder, railings, brackets, gates and similar
works including cost of materials, labour, usage charges of machinery
complete as per specifications and as per directions of the Engineer-in-
Charge. | Kgs | 163.69 | 163.69 | 75.6 | False | None | None | False | None | False | 12374.964 | 0 | 3645735 | 132901 | None | V-2 P-149 I-15.2 | Providing and Applying PU based Elastomeric Liquid Applied PU
Waterproofing Membrane single component, cold applied, water based
acrylic PU dispersion with highly elastic and UV resistant water proofing
treatment to the Existing Roof surface/Chajjas/Sunken portion of
WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than
1.5N/mm2, elongation greater than 300% with solid content not less than
60% in 2 coats including surface preparation, priming the surface with
water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile
between two top coats completely as per specification. The finished cost
to include surface preparation, making coving at Junction, Bore Packing,
treatment of construction joints completely as per specification | Sqm | 983.34 | 983.34 | 113.23 | False | None | None | False | None | False | 111343.5882 | 0 |
| 1722332830000 | 0 | None | None | Buildings | CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT NIDLAGHATTA IN MADDUR TALUKA OF MANDYA DISTRICT. (Water Supply & Sanitary Works) | 278247.83 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3645736 | 132902 | None | I-655 P-A44 V-5 | PVC pipe-OD 50mm & 6Kg/Sqcm GF | m | 61.36 | 61.36 | 20.0 | False | None | None | False | None | False | 1227.2 | 0 | 3645737 | 132902 | None | I-655 P-A44 V-5 | PVC pipe-OD 50mm & 6Kg/Sqcm FF | m | 61.97 | 61.97 | 25.0 | False | None | None | False | None | False | 1549.25 | 0 | 3645738 | 132902 | None | I-657 P-A44 V-5 | PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines GF | m | 145.14 | 145.14 | 20.0 | False | None | None | False | None | False | 2902.8 | 0 | 3645739 | 132902 | None | I-657 P-A44 V-5 | PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines FF | m | 146.59 | 146.59 | 25.0 | False | None | None | False | None | False | 3664.75 | 0 | 3645740 | 132902 | None | I-647 P-A44 V-5 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines GF | m | 300.9 | 300.9 | 40.0 | False | None | None | False | None | False | 12036.0 | 0 | 3645741 | 132902 | None | I-647 P-A44 V-5 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines FF | m | 303.91 | 303.91 | 60.0 | False | None | None | False | None | False | 18234.6 | 0 | 3645742 | 132902 | None | I-649 P-A44 V-5 | PVC pipe - OD 160mm and 6 Kg/sqcm, sanitary lines GF | m | 495.6 | 495.6 | 40.0 | False | None | None | False | None | False | 19824.0 | 0 | 3645743 | 132902 | None | I-13.48 P-125 V-2 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GF | m | 343.38 | 343.38 | 20.0 | False | None | None | False | None | False | 6867.6 | 0 | 3645744 | 132902 | None | I-37.28.1 S.R 2018-19 | Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick GF | Nos | 154.58 | 154.58 | 4.0 | False | None | None | False | None | False | 618.32 | 0 | 3645745 | 132902 | None | I-37.28.1 S.R 2018-19 | Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick FF | Nos | 156.13 | 156.13 | 4.0 | False | None | None | False | None | False | 624.52 | 0 | 3645746 | 132902 | None | I-37.28.2 S.R 2018-19 | Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick GF | Nos | 185.26 | 185.26 | 4.0 | False | None | None | False | None | False | 741.04 | 0 | 3645747 | 132902 | None | I-37.28.2 S.R 2018-19 | Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 10 cms thick FF | Nos | 187.11 | 187.11 | 4.0 | False | None | None | False | None | False | 748.44 | 0 | 3645748 | 132902 | None | I-14.32.2 P-136 V-2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm GF | Each | 1201.24 | 1201.24 | 1.0 | False | None | None | False | None | False | 1201.24 | 0 | 3645749 | 132902 | None | I-14.32.2 P-136 V-2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm FF | Each | 1213.25 | 1213.25 | 1.0 | False | None | None | False | None | False | 1213.25 | 0 | 3645750 | 132902 | None | I-13.9.2 P-118 V-2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter GF | Nos | 329.22 | 329.22 | 1.0 | False | None | None | False | None | False | 329.22 | 0 | 3645751 | 132902 | None | I-13.9.2 P-118 V-2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter FF | Nos | 332.51 | 332.51 | 1.0 | False | None | None | False | None | False | 332.51 | 0 | 3645752 | 132902 | None | I-14.22B P-135 V-2 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. GF | Nos | 6563.16 | 6563.16 | 1.0 | False | None | None | False | None | False | 6563.16 | 0 | 3645753 | 132902 | None | I-14.22B P-135 V-2 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. FF | Nos | 6628.79 | 6628.79 | 1.0 | False | None | None | False | None | False | 6628.79 | 0 | 3645754 | 132902 | None | I-14.40.2 P-137 V-2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. GF | Nos | 585.28 | 585.28 | 1.0 | False | None | None | False | None | False | 585.28 | 0 | 3645755 | 132902 | None | I-14.40.2 P-137 V-2 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. FF | Nos | 591.13 | 591.13 | 1.0 | False | None | None | False | None | False | 591.13 | 0 | 3645756 | 132902 | None | I-14.3.1 P-131 V-2 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid GF | Nos | 7052.86 | 7052.86 | 1.0 | False | None | None | False | None | False | 7052.86 | 0 | 3645757 | 132902 | None | I-14.3.1 P-131 V-2 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid FF | Nos | 7123.39 | 7123.39 | 1.0 | False | None | None | False | None | False | 7123.39 | 0 | 3645758 | 132902 | None | I-14.4.4 P-132 V-2 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern GF | Nos | 15422.6 | 15422.6 | 1.0 | False | None | None | False | None | False | 15422.6 | 0 | 3645759 | 132902 | None | I-14.4.4 P-132 V-2 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern FF | Nos | 15576.83 | 15576.83 | 1.0 | False | None | None | False | None | False | 15576.83 | 0 | 3645760 | 132902 | None | I-14.11.2 P-134 V-2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm GF | Nos | 5996.76 | 5996.76 | 2.0 | False | None | None | False | None | False | 11993.52 | 0 | 3645761 | 132902 | None | I-14.11.2 P-134 V-2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm FF | Nos | 6056.73 | 6056.73 | 2.0 | False | None | None | False | None | False | 12113.46 | 0 | 3645762 | 132902 | None | I-13.32.2 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes GF | m | 447.22 | 447.22 | 10.0 | False | None | None | False | None | False | 4472.2 | 0 | 3645763 | 132902 | None | I-13.32.2 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes FF | m | 451.69 | 451.69 | 10.0 | False | None | None | False | None | False | 4516.9 | 0 | 3645764 | 132902 | None | I-13.32.3 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes GF | m | 562.86 | 562.86 | 60.0 | False | None | None | False | None | False | 33771.6 | 0 | 3645765 | 132902 | None | I-13.32.3 P-122 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia Pipes FF | m | 568.49 | 568.49 | 50.0 | False | None | None | False | None | False | 28424.5 | 0 | 3645766 | 132902 | None | I-813 P-A36 V-2 | SS Bib cock with wall flange GF | Nos | 979.4 | 979.4 | 5.0 | False | None | None | False | None | False | 4897.0 | 0 | 3645767 | 132902 | None | I-813 P-A36 V-2 | SS Bib cock with wall flange FF | Nos | 989.19 | 989.19 | 5.0 | False | None | None | False | None | False | 4945.95 | 0 | 3645768 | 132902 | None | I-16.10 P-191 V-5 | Constructing brick masonry chamber of internal dimension 450x450mm
and depth of 600mm (inner dimensions) with modular bricks of CD 75
in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering
12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing
CI cover & frame etc including the cost of CI frame and cover | Each | 4998.48 | 4998.48 | 4.0 | False | None | None | False | None | False | 19993.92 | 0 | 3645769 | 132902 | None | I-13.34 P-123 V-2 | Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, IS : 12701 marked, with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank. | l | 10.73 | 10.73 | 2000.0 | False | None | None | False | None | False | 21460.0 | 0 |
| 1722332830000 | 0 | None | None | Buildings | CONSTRUCTION OF HEALTH & WELLNESS CENTRE AT NIDLAGHATTA IN MADDUR TALUKA OF MANDYA DISTRICT. (Electrical Works) | 438375.71 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3645770 | 132903 | None | 2.2.1 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch | Point | 317.42 | 317.42 | 20.0 | False | None | None | False | None | False | 6348.4 | 0 | 3645771 | 132903 | None | 2.2.2 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3mtr up to 6Mtr from tapping point to out let via switch | Point | 447.22 | 447.22 | 15.0 | False | None | None | False | None | False | 6708.3 | 0 | 3645772 | 132903 | None | 2.2.3 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Above 6Mtr up to 10Mtr from tapping Point to out let via switch | Point | 654.9 | 654.9 | 10.0 | False | None | None | False | None | False | 6549.0 | 0 | 3645773 | 132903 | None | 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 Way | Each | 187.62 | 187.62 | 4.0 | False | None | None | False | None | False | 750.48 | 0 | 3645774 | 132903 | None | 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way | Each | 208.86 | 208.86 | 2.0 | False | None | None | False | None | False | 417.72 | 0 | 3645775 | 132903 | None | 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way | Each | 259.6 | 259.6 | 10.0 | False | None | None | False | None | False | 2596.0 | 0 | 3645776 | 132903 | None | 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way | Each | 307.98 | 307.98 | 5.0 | False | None | None | False | None | False | 1539.9 | 0 | 3645777 | 132903 | None | 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way | Each | 376.42 | 376.42 | 10.0 | False | None | None | False | None | False | 3764.2 | 0 | 3645778 | 132903 | None | 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module | Each | 189.98 | 189.98 | 4.0 | False | None | None | False | None | False | 759.92 | 0 | 3645779 | 132903 | None | 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module | Each | 206.5 | 206.5 | 2.0 | False | None | None | False | None | False | 413.0 | 0 | 3645780 | 132903 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module | Each | 276.12 | 276.12 | 10.0 | False | None | None | False | None | False | 2761.2 | 0 | 3645781 | 132903 | None | 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Each | 335.12 | 335.12 | 5.0 | False | None | None | False | None | False | 1675.6 | 0 | 3645782 | 132903 | None | 3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module | Each | 405.92 | 405.92 | 10.0 | False | None | None | False | None | False | 4059.2 | 0 | 3645783 | 132903 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way. | Each | 120.36 | 120.36 | 120.0 | False | None | None | False | None | False | 14443.2 | 0 | 3645784 | 132903 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket. | Each | 201.78 | 201.78 | 20.0 | False | None | None | False | None | False | 4035.6 | 0 | 3645785 | 132903 | None | 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. | Each | 421.26 | 421.26 | 10.0 | False | None | None | False | None | False | 4212.6 | 0 | 3645786 | 132903 | None | 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch | Each | 212.4 | 212.4 | 20.0 | False | None | None | False | None | False | 4248.0 | 0 | 3645787 | 132903 | None | 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch | Each | 384.68 | 384.68 | 4.0 | False | None | None | False | None | False | 1538.72 | 0 | 3645788 | 132903 | None | 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket | Each | 278.48 | 278.48 | 10.0 | False | None | None | False | None | False | 2784.8 | 0 | 3645789 | 132903 | None | 3.6.12 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket | Each | 184.08 | 184.08 | 2.0 | False | None | None | False | None | False | 368.16 | 0 | 3645790 | 132903 | None | I-1.13 | Supplyin and Fixing Metal Fan Box with Round Hook. | No | 138.06 | 138.06 | 10.0 | False | None | None | False | None | False | 1380.6 | 0 | 3645791 | 132903 | None | 1.2.1 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick | m | 77.88 | 77.88 | 90.0 | False | None | None | False | None | False | 7009.2 | 0 | 3645792 | 132903 | None | 1.2.2 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick | m | 92.04 | 92.04 | 150.0 | False | None | None | False | None | False | 13806.0 | 0 | 3645793 | 132903 | None | 1.2.3 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2mm thick | m | 121.54 | 121.54 | 30.0 | False | None | None | False | None | False | 3646.2 | 0 | 3645794 | 132903 | None | 1.7.1 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50mm conduit in brick wall | m | 34.22 | 34.22 | 60.0 | False | None | None | False | None | False | 2053.2 | 0 | 3645795 | 132903 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm | m | 30.68 | 30.68 | 180.0 | False | None | None | False | None | False | 5522.4 | 0 | 3645796 | 132903 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm | m | 49.56 | 49.56 | 1080.0 | False | None | None | False | None | False | 53524.8 | 0 | 3645797 | 132903 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm | m | 74.34 | 74.34 | 360.0 | False | None | None | False | None | False | 26762.4 | 0 | 3645798 | 132903 | None | 5.19.4 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure( Double Door) 12 Way SP & N | Each | 2198.34 | 2198.34 | 2.0 | False | None | None | False | None | False | 4396.68 | 0 | 3645799 | 132903 | None | 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A SP | Each | 489.7 | 489.7 | 20.0 | False | None | None | False | None | False | 9794.0 | 0 | 3645800 | 132903 | None | 5.18.4 | Supplying & fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DP | Each | 872.02 | 872.02 | 8.0 | False | None | None | False | None | False | 6976.16 | 0 | 3645801 | 132903 | None | I-32.05 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16 sqmm | Km | 167373.56 | 167373.56 | 0.25 | False | None | None | False | None | False | 41843.39 | 0 | 3645802 | 132903 | None | 11.3.2 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w | Each | 814.2 | 814.2 | 20.0 | False | None | None | False | None | False | 16284.0 | 0 | 3645803 | 132903 | None | 11.4.1 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 5-6 W, | Each | 949.9 | 949.9 | 6.0 | False | None | None | False | None | False | 5699.4 | 0 | 3645804 | 132903 | None | I-6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 6.0 | False | None | None | False | None | False | 10563.36 | 0 | 3645805 | 132903 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model | Each | 3521.12 | 3521.12 | 10.0 | False | None | None | False | None | False | 35211.2 | 0 | 3645806 | 132903 | None | 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders | Each | 143.96 | 143.96 | 20.0 | False | None | None | False | None | False | 2879.2 | 0 | 3645807 | 132903 | None | I-13.10 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 10.0 | False | None | None | False | None | False | 2017.8 | 0 | 3645808 | 132903 | None | I-13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Each | 834.26 | 834.26 | 6.0 | False | None | None | False | None | False | 5005.56 | 0 | 3645809 | 132903 | None | 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts | No | 4748.32 | 4748.32 | 2.0 | False | None | None | False | None | False | 9496.64 | 0 | 3645810 | 132903 | None | 13.4.1 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length | Each | 1723.98 | 1723.98 | 2.0 | False | None | None | False | None | False | 3447.96 | 0 | 3645811 | 132903 | None | I-13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. | Each | 191.16 | 191.16 | 1.0 | False | None | None | False | None | False | 191.16 | 0 | 3645812 | 132903 | None | 5.42.2 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG | Sq CM | 0.51 | 0.51 | 36000.0 | False | None | None | False | None | False | 18360.0 | 0 | 3645813 | 132903 | None | 5.40.1 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips | m | 2908.7 | 2908.7 | 2.0 | False | None | None | False | None | False | 5817.4 | 0 | 3645814 | 132903 | None | 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm | m | 359.9 | 359.9 | 6.0 | False | None | None | False | None | False | 2159.4 | 0 | 3645815 | 132903 | None | 5.15.1 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) FOUR POLE 100Amps 25kA | Each | 7181.48 | 7181.48 | 1.0 | False | None | None | False | None | False | 7181.48 | 0 | 3645816 | 132903 | None | 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN | Each | 3591.92 | 3591.92 | 2.0 | False | None | None | False | None | False | 7183.84 | 0 | 3645817 | 132903 | None | I-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C | Each | 607.7 | 607.7 | 2.0 | False | None | None | False | None | False | 1215.4 | 0 | 3645818 | 132903 | None | I-5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound | Each | 663.16 | 663.16 | 3.0 | False | None | None | False | None | False | 1989.48 | 0 | 3645819 | 132903 | None | I-5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Each | 10991.7 | 10991.7 | 2.0 | False | None | None | False | None | False | 21983.4 | 0 | 3645820 | 132903 | None | Item | Electrical Deposite for Power Sanction | LS | 35000.0 | 35000.0 | 1.0 | False | None | None | False | None | False | 35000.0 | 0 |
|
|
---|