createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1722404788390
version9
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3320.00
emd199000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-08-2024 17:30:00
tenderQueryClose07-08-2024 11:00:00
technicalBidOpen14-08-2024 11:00:00
publishedDate01-08-2024 17:28:18
publishedByPostKSPHIDCL_EECNT_CNT_BNG
publishedByUserKPE13762 - SHIVAPRAKASH G
bidValidityPeriod90
noOfCalls1
preBidMeetingDate08-08-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVAPRAKASH G
splitEmdRequiredYnTrue
emdBankGuarantee99000.00
emdCash100000.00
bgValidityPeriod120
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08025584130
mobileNumber7892672609
tenderSupplierListNone
tenderSchedule
createdTs1722404788416
version13
createdDateNone
modifiedDateNone
tenderNumberKSPHIDCL/2024-25/BD/WORK_INDENT121
titleConstruction of Grade-3 Police Station at Kodigenahalli in Madhugiri Taluk in Tumkur District
descriptionConstruction of Grade-3 Police Station at Kodigenahalli in Madhugiri Taluk in Tumkur District
categoryWORKS
categoryTextWorks
ecv13262465.53
deptNameKarnataka State Police Housing and Infrastructure Development Corporation Limited
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location7550
locationNameKSPHIDCL Contracts Section Bengaluru
provisionalAmount15200000.0
groupOverheadTotal0.0
fileNumberPHC/CNT/BNG(R)/TND/17/2024-25/WI-121
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17224047880000NoneNoneBuildingsConstruction of grade 3 Police Station at kodigenehalli in Madhugiri Taluk in Tumkur District Civil9673172.91
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3653865133300NoneVOL-I Item No 1.12Page No-8Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum112.1112.1134.55FalseNoneNoneFalseNoneFalse15083.0550
3653866133300NoneVOL-I Item No 1.4.2Page No-5Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5m, but not exceeding 3 mCum120.36120.36282.61FalseNoneNoneFalseNoneFalse34014.93960
3653867133300NoneVOL-I Item No 1.5.1Page No-6Earth work excavation for Foundation by manual means for all Buildings,Bridges, Retaining walls, Abutment Piers and such similar works as per drawing and technical Specifications, including setting out, providing shoring & strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum270.22270.2270.66FalseNoneNoneFalseNoneFalse19093.74520
3653868133300NoneVol-II Item No.4.1 Page No.5Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm139.24139.24211.82FalseNoneNoneFalseNoneFalse29493.81680
3653869133300NoneVol-I Item No2.1.3 Page No. 15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregateCum7067.27067.254.77FalseNoneNoneFalseNoneFalse387070.5440
3653870133300NoneVol-I Item No 2.5.2 Page No. 16Providing and laying in Cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates for Grade Beam & Columns footingsCum8074.698074.6973.94FalseNoneNoneFalseNoneFalse597042.57860
3653871133300NoneVOL-I Item No 1.9 Page No-7Filling available excavated earth ( excluding rock) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications No.KSB 2.9Cum313.88313.88187.8FalseNoneNoneFalseNoneFalse58946.6640
3653872133300NoneVOL-I Item No 1.9 Page No-A60Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the workCum474.36474.36165.47FalseNoneNoneFalseNoneFalse78492.34920
3653873133300NoneVOL-II Item No. 6.32 Page No. 17 ground floor Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1545.81545.8270.3FalseNoneNoneFalseNoneFalse417829.740
3653874133300NoneVOL-II Item No. 6.32 Page No. 17Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. For First FloorSqm1561.261561.26226.66FalseNoneNoneFalseNoneFalse353875.19160
3653875133300NoneVOL-II Item No. 6.34 Page No. 17Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1302.721302.72160.46FalseNoneNoneFalseNoneFalse209034.45120
3653876133300NoneVOL-II Item No. 6.34 Page No. 17Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1315.751315.7535.9FalseNoneNoneFalseNoneFalse47235.4250
3653877133300NoneVol-I Item No 2.1.4 Page No. 15Providing and laying in position Cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:3:6 M10 Design Mix Using 20 mm and down size graded crushed coarse aggregates Ground floorCum7279.037279.030.44FalseNoneNoneFalseNoneFalse3202.77320
3653878133300NoneVol-I Item No 2.1.4 Page No. 15Providing and laying in position Cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:3:6 M10 Design Mix Using 20 mm and down size graded crushed coarse aggregates First floorCum7137.697137.690.29FalseNoneNoneFalseNoneFalse2069.93010
3653879133300NoneVol-I Item No 2.5.2 Page No. 16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.Cum13727.0613727.0615.82FalseNoneNoneFalseNoneFalse217162.08920
3653880133300NoneVol-I Item No 2.5.2 Page No. 16Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) for Lintel and cills Concrete LintelCum12919.5812919.584.67FalseNoneNoneFalseNoneFalse60334.43860
3653881133300NoneVol-I Item No 2.5.2 Page No. 16Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) for Lintel and cills Concrete Stair caseCum11708.3711708.378.27FalseNoneNoneFalseNoneFalse96828.21990
3653882133300NoneVol-I Item No 2.5.2 Page No. 16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.Cum13864.3313864.335.0FalseNoneNoneFalseNoneFalse69321.650
3653883133300NoneVol-I Item No 2.5.2 Page No. 16 Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. FF LINTELSCum13048.7813048.782.42FalseNoneNoneFalseNoneFalse31578.04760
3653884133300NoneVol-I Item No 2.5.2 Page No.16Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) for Roof beamCum12919.5812919.5814.45FalseNoneNoneFalseNoneFalse186687.9310
3653885133300NoneVol-I Item No 2.5.2 Page No.16Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) for Roof beam FFCum13048.7813048.785.84FalseNoneNoneFalseNoneFalse76204.87520
3653886133300NoneVol-I Item No 2.5.2 Page No.16Providing and laying in position Cement concrete M25 for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) for roof slabCum12112.1112112.1134.79FalseNoneNoneFalseNoneFalse421380.30690
3653887133300NoneVol-I Item No 2.5.2 Page No.16Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) for roof slab FFCum12233.2412233.2413.53FalseNoneNoneFalseNoneFalse165515.73720
3653888133300NoneVol-I Item No 2.5.2 Page No.16Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.Chajjas Cum11708.3711708.371.52FalseNoneNoneFalseNoneFalse17796.72240
3653889133300NoneVol-I Item No 2.5.2 Page No.16Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.Chajjas for FFCum11825.4511825.451.26FalseNoneNoneFalseNoneFalse14900.0670
3653890133300Nonepage-15 item no.4.21KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering (labour charges only) as per specifications.Rmtr38.9438.9471.4FalseNoneNoneFalseNoneFalse2780.3160
3653891133300Nonepage-20 item no.4.54Providing RCC loft (atta) 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm down size with necessary reinforcements at 20cm c/c as per design including formwork, centring, curing, etc., complete (exclusive of cost of steel and fabrication charges)Sqm8074.748074.7418.96FalseNoneNoneFalseNoneFalse153097.07040
3653892133300NoneVol-II Item No. 15.1 P. No. 149Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single omponent, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm964.06964.06237.0FalseNoneNoneFalseNoneFalse228482.220
3653893133300Nonepage-20 item no.4.54Providing RCC loft (atta) 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm down size with necessary reinforcements at 20cm c/c as per design including formwork, centring, curing, etc., complete (exclusive of cost of steel and fabrication charges) Ground floorSqm8074.748074.747.43FalseNoneNoneFalseNoneFalse59995.31820
3653894133300Nonepage-20 item no.4.54Providing RCC loft (atta) 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm down size with necessary reinforcements at 20cm c/c as per design including formwork, centring, curing, etc., complete (exclusive of cost of steel and fabrication charges) FFSqm8074.748074.7412.05FalseNoneNoneFalseNoneFalse97300.6170
3653895133300Nonepage-20 item no.4.54Providing RCC loft (atta) 7.5cms thick with cement concrete design mix M20 using clean granite or trap jelly of 20mm down size with necessary reinforcements at 20cm c/c as per design including formwork, centring, curing,Sqm8074.748074.743.46FalseNoneNoneFalseNoneFalse27938.60040
3653896133300NoneVol-II Item No 8.10 Page No. 43Providing 6 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as perSqm248.98248.98205.12FalseNoneNoneFalseNoneFalse51070.77760
3653897133300NoneVol-II Item No 8.10 Page No. 43Providing 6mm cement plaster with cement mortor 1:3 (1 cement:3 fine sand) including rounding of corroners where ever required smooth rendering,providing and removing scafolding including cost of materials, curring complete as per specification and as per directions of engineer in chargeSqm251.34251.3473.67FalseNoneNoneFalseNoneFalse18516.21780
3653898133300NoneVol-II Item No 8.9 Page No. 42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm454.3454.336.33FalseNoneNoneFalseNoneFalse16504.7190
3653899133300NoneVol-II Item No 8.9 Page No. 42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge FFSqm458.84458.84269.79FalseNoneNoneFalseNoneFalse123790.44360
3653900133300NoneVol-II Item No 8.9 Page No. 42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm454.3454.3220.61FalseNoneNoneFalseNoneFalse100223.1230
3653901133300NoneVol-II Item No 8.9 Page No. 42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm458.84458.84288.53FalseNoneNoneFalseNoneFalse132389.10520
3653902133300NoneVol-II Item No 8.5.2 Page No. 42Providing rough cement plastering 15mm thick in single coat with cement mortar to brick masonry for base of dadooing works with sand of approved quality, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.KSRB15-5.1 :do cement mortar 1:4Sqm411.82411.8285.57FalseNoneNoneFalseNoneFalse35239.43740
3653903133300NoneVol-II Item No 8.5.2 Page No. 42Providing rough cement plastering 15mm thick in single coat with cement mortar to brick masonry for base of dadooing works with sand of approved quality, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.KSRB15-5.1 do cement mortar 1:4Sqm415.94415.9428.67FalseNoneNoneFalseNoneFalse11924.99980
3653904133300NoneVol-II Item No 8.9 Page No. 42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm454.3454.364.94FalseNoneNoneFalseNoneFalse29502.2420
3653905133300NoneVol-II Item No 8.30Page No. 46 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm205.32205.32205.12FalseNoneNoneFalseNoneFalse42115.23840
3653906133300NoneVol-II Item No 8.30Page No. 46 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm207.37207.3773.67FalseNoneNoneFalseNoneFalse15276.94790
3653907133300NoneVol-II Item No 8.30 Page No. 46 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm205.61205.61220.61FalseNoneNoneFalseNoneFalse45359.62210
3653908133300NoneVol-II Item No 8.30 Page No. 46 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm207.37207.37288.53FalseNoneNoneFalseNoneFalse59832.46610
3653909133300NoneVol-II Item No 8.30Page No. 46 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floorSqm205.32205.32595.09FalseNoneNoneFalseNoneFalse122183.87880
3653910133300NoneVol-II Item No 8.30Page No. 46 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. First floor First floorSqm207.37207.37269.79FalseNoneNoneFalseNoneFalse55946.35230
3653911133300NoneVol-II Item No 8.37 Page No. 48Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two coats) including a coat of approved steel primer but excluding a coat of mordant solution including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm220.66220.6682.38FalseNoneNoneFalseNoneFalse18177.97080
3653912133300NoneVol-II Item No 8.51 Page No. 50 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm118.0118.01143.67FalseNoneNoneFalseNoneFalse134953.060
3653913133300NoneVol-II Item No. 12.89 Page No.111Providing & fixing of 2.5-track x 2-panel sliding windows made out of multi chambered UPVCMatching to RAL-9016) sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI renforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mmThe cost is inclusive of all fixtures and separate charges for minor T&P's shall not be madeSqm7730.187730.1845.45FalseNoneNoneFalseNoneFalse351336.6810
3653914133300NoneVol-II Item No. 12.85 Page No. 110Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.Sqm6748.426748.424.5FalseNoneNoneFalseNoneFalse30367.890
3653915133300NoneVOL-II Item No.11.34 A Page No.86Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Kg198.24198.241729.92FalseNoneNoneFalseNoneFalse342939.34080
3653916133300None11.28 volume 2 page 85Providing and fixing Stainless steel 304 grade for staircase railings, balconies, ramps, with hand rail 50mm dia 16 guage hollow pipe welded to vertical hollow 50mm dia pipe of 16 guage, stainless steel vertical pipe spaced at 1.20m regular intervals, and 5 Nos.of 25mm dia. stainless steel hollow horizontal pipe are welded to vertical 50mm dia hollow pipe. The entire assembly is fixed to staircase concrete by using expansion bolts by drilling concrete etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc.,Kg666.7666.7258.7FalseNoneNoneFalseNoneFalse172475.290
3653917133300NoneVol-II Item No. 12.57.1 Page No. 105Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification. including cost of materials , labour chages for fixing fixtures.Etc with all lead and liftSqm5306.465306.4626.44FalseNoneNoneFalseNoneFalse140302.80240
3653918133300NoneVol-II Item No. 12.57.1 Page No. 105Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification. including cost of materials , labour chages for fixing fixtures.Etc with all lead and liftSqm5306.465306.469.45FalseNoneNoneFalseNoneFalse50146.0470
3653919133300NoneVol-II Item No. 12.13.1 Page No. 100Providing wood frames of doors, windows, clerestory windows, ventilators and other frames wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps but including cost of materials labour HOM complete as per specifications. Specification do Sal wood frameCum116601.7116601.70.74FalseNoneNoneFalseNoneFalse86285.2580
3653920133300NoneVol-II Item No. 12.13.1 Page No. 100Providing wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps but including cost of materialslabour HOM complete as per specifications. SpecificationCum116601.7116601.70.16FalseNoneNoneFalseNoneFalse18656.2720
3653921133300NoneVol-II Item No. 12.51 Page No. 104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.No1198.881198.8813.0FalseNoneNoneFalseNoneFalse15585.440
3653922133300NoneVol-II Item No. 12.51 Page No. 104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.No1198.881198.885.0FalseNoneNoneFalseNoneFalse5994.40
3653923133300NoneVol-II Item No 8.55.1 8.37 Page No. 51 & 48Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge.Sqm220.66220.6669.3FalseNoneNoneFalseNoneFalse15291.7380
3653924133300NoneVol-II Item No 9.22.2 page no 62Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water vabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints .Size of Tile 600x600 mmSqm1564.681564.68207.37FalseNoneNoneFalseNoneFalse324467.69160
3653925133300NoneVol-II Item No 9.22.2 page no 62Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water vabsorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints .Size of Tile 600x600 mmSqm1580.331580.3364.13FalseNoneNoneFalseNoneFalse101346.56290
3653926133300NoneVol-II Item No 9.11page no 60Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm1049.021049.0214.6FalseNoneNoneFalseNoneFalse15315.6920
3653927133300NoneVol-II Item No 9.11page no 60Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm1051.381051.386.3FalseNoneNoneFalseNoneFalse6623.6940
3653928133300None9.31 VOLUME 2 PAGE 64Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Sqm2826.12826.154.05FalseNoneNoneFalseNoneFalse152750.7050
3653929133300NoneVolume-II Item no 10.2 page-69Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.Rmtr387.04387.04121.18FalseNoneNoneFalseNoneFalse46901.50720
3653930133300NoneVol-II Item No 9.39 Page No. 65 Providing skirting, dadooing, rises of steps with colour glazed tiles6mm thick on 10mm thick cement plaster 1:3 and jointed with whitecement slurry over existing rough plaster surface using glazed tiles ofapproved make and size including cost of materials, labour, completeas per specifications.Sqm1709.821709.82114.24FalseNoneNoneFalseNoneFalse195329.83680
3653931133300NoneVol-I Item No 2.11.a Page No.18 Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Tonne105559.26105559.2614.0FalseNoneNoneFalseNoneFalse1477829.640
3653932133300NoneVol-I Item No 2.11.a Page No.18 Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FFTonne106614.85106614.852.0FalseNoneNoneFalseNoneFalse213229.70
3653933133300NoneVol-II Item No 8.49 Page No. 49Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directionsof Engineer-in-charge.cm4.724.7241000.0FalseNoneNoneFalseNoneFalse193520.00
3653934133300Nonepage 117 Item no.15.34Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120 gm2 width, along route of walls chipped for services junction between RCC and brick walls including cost of materialslabour for fixing complete as per specifications. length of mesh only measured for payRmtr40.1240.12600.12FalseNoneNoneFalseNoneFalse24076.81440
3653935133300NoneItem no 9.96 page no 63Providing and fixing 65mmx125mm GRP Doorframe fabricated using E-Glass Chopped Strand Mat (CSM) U.V- stabilized Isopthalic Gelcoat and Isopthalic resin. The thickness of the GRP skin shall not be less than 2.0mm. The doorframe consists of four segments, which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screws. The GRP frame shall be provided with wooden reinforcement on 6 locations for high screw holding capacity for fixing metalling hold fast and shall be consolidated by filling with medium density foam/Plaster of Paris with fibre reinforcement. Six Numbers of 260mmx25mmx5mm size S shaped M.S. flat hold fast shall be provided with the frame.Rmtr4770.744770.7441.7FalseNoneNoneFalseNoneFalse198939.8580
3653936133300Nonepage-62 item no.9.93Providing and fixing factory made single leaft rigid GRP Sandwich composite door shutter of 32mm thick, laminated with two GRP skins with wood grain finish, fabricated using U.V-stabilized Isopthalic Gelcoat and on layer of 45 gsm E-Glass Chopped strand Mat (CSM), impregnated with orthopthalic polyster resin. The thickness of the skins shall not be less than 1.5mm. Expanded Polystyrene (EPS) structural foam panel of 29mm thickness and a density of 20 Kg/m3 shall be used as core material. Wooden reinforcements made of Seasoned Salwood block of cross section not less than 28mmx32mm and also necessary salwood reinforcements for fixing the metal fittings such as tower bolts, aldrops, handles, etc, shall be provided. A structural adhesive compatible with EPS foam shall be used for bonding the core material, the Salwood reinforcement and the skins. The material and process for manufacturing the door shutters shall confirm to RV/TIFAC Composites Design centre Standards and specifications and the door shutters tested in confiramation to IS 4020-1994. The finish of shutter will be plain colour White/Ivory/Beige/Light Grey or any other colour using high quality pigments. Exclusing cost of fixtures and inclusive of supply of shutters to respective work spot.Sqm2950.02950.012.6FalseNoneNoneFalseNoneFalse37170.00
3653937133300NoneVol-II Item No 8.9 Page No. 42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm454.3454.3580.0FalseNoneNoneFalseNoneFalse263494.00
17224047880000NoneNoneBuildingsConstruction of grade 3 Police Station at kodigenehalli in Madhugiri Taluk in Tumkur District WATER SUPPLY571279.49
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3653938133301NoneVOL-I Item No 1.4.2Page No-5Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. -In all types of soil (P-8, I-2.23.1).Cum120.36120.3661.2FalseNoneNoneFalseNoneFalse7366.0320
3653939133301NoneVOL-I Item No 1.9 Page No-7Filling available excavated earth ( excluding rock) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specificationsCum313.88313.8818.36FalseNoneNoneFalseNoneFalse5762.83680
3653940133301None13.31.4Providing and fixing chorinated poly vinyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work).32mmRmtr463.74463.74125.0FalseNoneNoneFalseNoneFalse57967.50
3653941133301None13.33.6Providing and fixing Chorinated Poly Venyl Chloride (CPVC) 50mm pipes confirming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings , this including jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete. (external work)Rmtr828.36828.3660.0FalseNoneNoneFalseNoneFalse49701.60
3653942133301NoneVol-VItem No 13.31.3 Page No.Providing and fixing chlorinated poly vinyl chloride ( CPVC ) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all C P V C plain and brass threaded fittings, including fixing the pipe with clamp at 1.00 mtrs spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement , and the cost of cutting chases & making good the same including testing of joints complete (concealed work including cutting chase and good the walls) 25mmRmtr623.04623.04125.0FalseNoneNoneFalseNoneFalse77880.00
3653943133301None13.4.1 113Providing and fixing in position brass gate valve with C.I wheel of approved quality screwed end NB including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification no of 25mmdNos623.04623.044.0FalseNoneNoneFalseNoneFalse2492.160
3653944133301NoneVol-V Item No 13.6.4.2 Page No.Providing and fixing in position 50 mm nominal bore non-return valve vertical type of approved make including cost of all materials, labour and HOM of equipments with alll leads complete as per specifications.Nos1438.421438.422.0FalseNoneNoneFalseNoneFalse2876.840
3653945133301NoneVol-V Item No 13.70.3Providing and fixing to wall, ceiling and floor , medium density polythene pipes 6.00 kgf /sqcm working pressure 50 mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of materials, labour charges, HOM of equipments and testing complete as per specifications.Rmtr384.68384.6852.0FalseNoneNoneFalseNoneFalse20003.360
3653946133301NoneVol-V Item No 13.70.5Page No. 49Providing and fixing to wall, ceiling and floor , medium density polyethylene pipes 6.00 kgf /sqcm working pressure outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of materials, labour charges, HOM of equipments and testing complete as per specifications.Rmtr531.0531.0150.0FalseNoneNoneFalseNoneFalse79650.00
3653947133301NoneVol-V Item No 10.1.9 .7Page No. 113Providing and fixing to wall, ceiling and floor , medium density polyethylene pipes 6.00 kgf /sqcm working pressure outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of materials, labour charges, HOM of equipments and testing complete as per specifications160 mm diaRmtr739.86739.8650.0FalseNoneNoneFalseNoneFalse36993.00
3653948133301Noneol-II Item No. 14.35.1 Page No.127Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo IndianW.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gmsNos7994.57994.56.0FalseNoneNoneFalseNoneFalse47967.00
3653949133301Nonepg 90 12.112.2Providing stone ware gully trap of approved quality and fixing in C C 1:2:4 and plastering with C M 1:3 where ever necessary Size: 15 cm x 10 cmNos330.4330.44.0FalseNoneNoneFalseNoneFalse1321.60
3653950133301Nonepg 269 item no.37.35Making wall bores in brick masonry walls up to 045 m width for soil water pipe including necessary scaffoldingNos148.68148.6840.0FalseNoneNoneFalseNoneFalse5947.20
3653951133301Nonepg 269 item no.37.36.2Making wall bores in stone masonry walls up to 0.45 m width for soil/water pipe including redoing with CM 1:4 and scaffolding. size: 60 cm to 90 cm widthNos388.22388.2210.0FalseNoneNoneFalseNoneFalse3882.20
3653952133301None13.78, pg. no. 96Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 1996 with manhole lid and suitable locking arrangements making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials,labour, transport charges, HOM andtestingNos8057.048057.042.0FalseNoneNoneFalseNoneFalse16114.080
3653953133301None11.50.2, Pg. no. 73Constructing brick masonry inspection chamber 600 x 600 mm , and 450 mm depth, clear dimension for pipeline with one or two inlets , using table moulded non- modular bricks of class designation 50 in cement mortar 1:5, CI cover with frame light duty 455 610mm total weight of cover with frame to be not less than 39 kgs weight fo cover 23kgs and weight of frame 15kg) RCC top slab with cement concrete M15 with 20mm and downsize granite metal, foundation concrete M5 with 40 mm and downsize granite metal inside plastering 12 mm cement on walls and bed concrete complete as per standard design including cost of materials,labour charges, curing complete as per specifications.Nos10018.210018.28.0FalseNoneNoneFalseNoneFalse80145.60
3653954133301NoneVolum 5 12.111 Pg. no. 90Providing & Fixing in position C P grating -7.5 cms to 15.00 cms dia grating 100mm diaNos177.0177.016.0FalseNoneNoneFalseNoneFalse2832.00
3653955133301NoneVol-II Item No. 14.31 Page No.126Providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Nos1340.481340.486.0FalseNoneNoneFalseNoneFalse8042.880
3653956133301NoneVol-II Item No. 14.7.1Page No.122Providing and fixing white vitreous china clay, flat back wash basin with a single 15mm C.P brass pillar tap with C.I M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. SpecificationNos3115.23115.26.0FalseNoneNoneFalseNoneFalse18691.20
3653957133301NoneVol-II Item No. 14.40.2 Page No.128Providing and fixing CP brass Towel rail 600 mm length, 20 mm dia, with CP brackets, fixed to wooden cleats with CP brass screws including cost of materials, labour complete as per specifications.Nos448.4448.46.0FalseNoneNoneFalseNoneFalse2690.40
3653958133301NoneNSRProviding and fixing CP. Health faucet with flexible hose,CP Angle valve, wall flange, supporting hook with screws, fixing materials and sealant to all sides of wall flange completeNos1593.01593.06.0FalseNoneNoneFalseNoneFalse9558.00
3653959133301NoneNSRProviding and fixing in position CP bib cock (with face plate) of approved quality 15 mm nominal bore including cost of all materials, labour and HOM of equipments with alll leads complete as per specificationsNos1475.01475.06.0FalseNoneNoneFalseNoneFalse8850.00
3653960133301NoneNSRProviding and fixing in position C P concealed stop cock (with face plate) for shower control arrangements including the cost of all materials, labour and HOM of equipments etc complete as per directions of engineer in chargNos1475.01475.08.0FalseNoneNoneFalseNoneFalse11800.00
3653961133301NoneNSRProviding and fixing in position CP bib cock (with face plate) of approved quality 15 mm nominal bore including cost of all materials, labour and HOM of equipments with alll leads complete as per specificationsNos1593.01593.08.0FalseNoneNoneFalseNoneFalse12744.00
17224047890000NoneNoneBuildingsConstruction of grade 3 police station at kodegenahalli in Tumkur district SUMP277620.25
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3653962133302NoneVOL-I Item No 1.4.2Page No-5Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & otherappurtenaces required to complete the work Depth exceeding 1.5m, but not exceeding3Cum120.36120.361.82FalseNoneNoneFalseNoneFalse219.05520
3653963133302NoneVOL-I Item No 1.5.1Page No-6Earth work excavation for Foundation by manual means for all Buildings,Bridges, Retaining walls, Abutment Piers and such similar works as per drawing and technical Specifications, including setting out, providing shoring & strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depthCum270.2270.231.76FalseNoneNoneFalseNoneFalse8581.5520
3653964133302NoneVol-I Item No2.1.3 Page No. 15Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregateNos7067.027067.021.91FalseNoneNoneFalseNoneFalse13498.00820
3653965133302NoneVol-I Item No 2.4.3 Page No. 16Providing and laying in Cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement & formwork to be paid separately M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates FootingCum8074.698074.693.17FalseNoneNoneFalseNoneFalse25596.76730
3653966133302NoneVol-I Item No 2.5.2 Page No.16Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) for roof slabCum12112.1112112.118.21FalseNoneNoneFalseNoneFalse99440.42310
3653967133302NoneVOL-I Item No 1.9 Page No-7Filling available excavated earth ( excluding rock) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specificationsCum313.88313.8811.45FalseNoneNoneFalseNoneFalse3593.9260
3653968133302None1.85Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) for roof slabCum12112.1112112.111.85FalseNoneNoneFalseNoneFalse22407.40350
3653969133302NoneVol-II Item No 8.9 Page No. 42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm454.3454.319.6FalseNoneNoneFalseNoneFalse8904.280
3653970133302NoneVol-II Item No 8.1.1Page No. 41Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm300.9300.912.68FalseNoneNoneFalseNoneFalse3815.4120
3653971133302NoneVol-II Item No 8.9 Page No. 42Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm454.3454.315.68FalseNoneNoneFalseNoneFalse7123.4240
3653972133302NoneVol-I Item No 2.11.a Page No.18 Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Kg105.55105.55800.0FalseNoneNoneFalseNoneFalse84440.00
17224047890000NoneNoneBuildingsConstruction of grade 3 police station at kodegenahalli in Tumkur district BORE WELL400503.75
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3653973133303NoneCSR 2022 Vol-V, It. No.O040A Pg No.151Geophysical investigation at site for sinking borewells for supplyingdrinking water to the habitation either through the Hand Pump MWS orP.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geologicalformation. Geophysical investigation of existing ground water in thevicinity, its quality, quantity and acceptability of the users, indicatingthe location of the site, recommended depth of casing pipe required toseal the top unconsolidated formation including an extra depth of 1.0metre in consolidated formation for proper seating of casing pipe, depthof drilling required to cover full depth of aquifer proposed to be tapped,probable yield and other information required including transportationof instruments and accessories to work site, engaging technical personaland labour required etc. NOTE: 1) Additional rate on item 1&2 isallowed for drilling in over burden and fixing Casing pipes beyond 20 M(for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%,b) Above 30 M - 30% (Measurement of overburden is restricted to thedepth of casing pipe fixed excluding initial depth of 20M and projectionabove ground level). 2) A sum of Rs. 100/- is to be deducted for DryBorewell towards yield test.Each6427.046427.041.0FalseNoneNoneFalseNoneFalse6427.040
3653974133303NoneCSR 2022 Vol-V, It. No.O020A Pg No.151Sinking borewell of 150mm dia. clear, using super fast hydraulic rig ofcapacity 250 PSIG & above 900 CMF and above, in all strata of earth,including over burden upto 20M, fixing of casing pipes, collars and capwith ncessary cutting, threading and welding including transportation ofrig and supporting vehicles, crew charges, cost of consumables, cost ofyield test at the final depth with a minimum working of compressor forone hour etc. complete. The cost excludes the cost of casing pipes,collars and caps etc.) for:Rmtr563.95563.9550.0FalseNoneNoneFalseNoneFalse28197.50
3653975133303NoneCSR 2022 Vol-V, It. No.O020B Pg No.151Above 50 - 100 mtsRmtr449.7449.750.0FalseNoneNoneFalseNoneFalse22485.00
3653976133303NoneCSR 2022 Vol-V, It. No.O020C Pg No.151Above 100 - 150 mtsRmtr599.19599.1950.0FalseNoneNoneFalseNoneFalse29959.50
3653977133303NoneCSR 2022 Vol-V, It. No.O020D Pg No.151Above 150 - 200 mtsRmtr695.21695.2150.0FalseNoneNoneFalseNoneFalse34760.50
3653978133303NoneCSR 2022 Vol-V, It. No.O020E Pg No.151Above 200 - 250 mtsRmtr815.33815.3350.0FalseNoneNoneFalseNoneFalse40766.50
3653979133303NoneCSR 2022 Vol-V, It. No.O020F Pg No.151Above 250 - 300 mtsRmtr899.4899.450.0FalseNoneNoneFalseNoneFalse44970.00
3653980133303NoneCSR 2022 Vol-V, It. No.O020G Pg No.151Above 300 - 350 mtsRmtr1054.971054.9750.0FalseNoneNoneFalseNoneFalse52748.50
3653981133303NoneCSR 2022 Vol-V, It. No.O020G Pg No.151Above 350 - 400 mtsRmtr1138.831138.8350.0FalseNoneNoneFalseNoneFalse56941.50
3653982133303NoneCSR 2022 Vol-II, It. No.336 Pg No.A22M.S. pipe 150 mm dia casing pipeRmtr1165.571165.5770.0FalseNoneNoneFalseNoneFalse81589.90
3653983133303NoneCSR 2022 Vol-V, It. No.1818,D&R Pg No.54Providing and fixing MS casing collarsEach182.31182.318.0FalseNoneNoneFalseNoneFalse1458.480
3653984133303NoneCSR 2022 Vol-V, SL. No.1105,5888 Pg No.32MS casing capsEach199.33199.331.0FalseNoneNoneFalseNoneFalse199.330
17224047890000NoneNoneBuildingsConstruction of grade 3 police station at kodegenahalli in Tumkur district ESTIMATES FOR FURNITURES382722.38
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3653985133304NoneNSR 1L Shape Table: Providing and fixing L Shape Table, table top made up of 25mm thick ply with post laminated MS powder coated alpha leg under structure with supporing metal modesty inclusive of standard pedestal. The drawers shall be mounted on telescopic slides fitted with brushed finish SS handels withall lead, lifts, loading, unloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and as per the directions of the Engineer in-charge of the work, Size 1800x900x750mm ht and 900x600x750mm ht.Nos36174.0836174.081.0FalseNoneNoneFalseNoneFalse36174.080
3653986133304NoneNSR 2Executive chair: Providng & installing revolving type Executive chair with height adj, synchro tilt mechanism with 5 position lock system, mesh back for free air supply with good lumber suport, adj arms, nylon base with unbreakable twin wheel castors model: crown. with all lead, lifts, loading, unloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work.Nos26187.7426187.741.0FalseNoneNoneFalseNoneFalse26187.740
3653987133304NoneNSR 3Visitor chair: Providng & installing Fixed type Visitor chair with mesh back for free air supply, MS powder coated tubluar under structure, model comfort vistor. with all lead, lifts, loading, unloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work.Nos4888.744888.7410.0FalseNoneNoneFalseNoneFalse48887.40
3653988133304NoneNSR 4Work station : Providng & installing Table top made up of 25mm thick PLPB with approved laminate color with matching edge banding profile, vertical support to be 75mm thick partitions below table top laminate tiles, above table top one marker/one pin up board for each W/S, Inclusive of standard pedestal with all lead, lifts, loading, unloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work. 1200x600x1200Nos21824.121824.14.0FalseNoneNoneFalseNoneFalse87296.40
3653989133304NoneNSR 5Executive chair: Providng & installing Revoiving type Executive chair with height adj, synchro tilt mechanism with single position lock system, mesh back for free air supply, adj arms, nylon base with unbreakale twin wheel castors model: comfor MBK. with all lead, lifts, loading, unloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work.Nos5935.45935.46.0FalseNoneNoneFalseNoneFalse35612.40
3653990133304NoneNSR 6Providng & installing Metal Tandem chair three seater. with all lead, lifts, loading, unloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work.Nos7858.87858.82.0FalseNoneNoneFalseNoneFalse15717.60
3653991133304NoneNSR 7Providng installing Free standing table made up of 25 mm thick ply post laminated with approved laminate shade with matching edge banding profile, with supporting gable ends with supporting modesty, table size in mm 1200x900x750ht . with all lead, lifts, loadingunloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer incharge of the work.Nos.19029.8619029.862.0FalseNoneNoneFalseNoneFalse38059.720
3653992133304NoneNSR 8Providng & installing Cot: made up of CRCA of 14G. uniformly bent on sides vertically and further inside and with one lengthwise rib of 14G in the middle underneath. The verticals shall be made out of 38mm square MS tubes of 16G thick on all the four comers & 19mm square MS tubes in between. with approved powder coating color with supporting MS Powder coated tubular legs with mattress, size in mm :1800X750X600ht. with all lead, lifts, loading, unloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work.Nos.15052.0815052.084.0FalseNoneNoneFalseNoneFalse60208.320
3653993133304NoneNSR 9Providng & installing Plastic chairs for auditorium with all lead, lifts, loading, unloading, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work.Nos.1571.761571.7622.0FalseNoneNoneFalseNoneFalse34578.720
17224047890000NoneNoneBuildingsConstruction of grade 3 police station at kodegenahalli in Tumkur district ELECTRICAL1957166.75
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3653994133305None1.2.1Electrical - Concealed Conduit System Supplying heavy gauge PVC conduit pipe …19/20…mm dia .2.mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary,as per the directions of Engineer in charge of the work. 1) 19/20mm dia 2mm thickMtr77.8877.88500.0FalseNoneNoneFalseNoneFalse38940.00
3653995133305None1.2.2Concealed Conduit System - Supplying heavy gauge PVC conduit pipe …25…mm dia .2.mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary and as per the directions of Engineer in charge of the work. 2) 25mm dia 2mm thickMtr92.0492.04400.0FalseNoneNoneFalseNoneFalse36816.00
3653996133305None1.12Supplying and Fixing Metal Fan Box with Round Hook. and as per the directions of Engineer in charge of the work.Each188.8188.824.0FalseNoneNoneFalseNoneFalse4531.20
3653997133305None1.3.1Groove cutting Supplying heavy gauge PVC Conduit Pipe 19 20….dia .2.mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary ,as per the directions of Engineer in charge of the work. 1) 19/20mm dia 2mm thickMtr80.2480.24300.0FalseNoneNoneFalseNoneFalse24072.00
3653998133305None1.3.2Groove cutting Supplying heavy gauge PVC Conduit Pipe 25.dia .2.mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary ,as per the directions of Engineer in charge of the work. 25mm dia 2mm thickMtr93.2293.22200.0FalseNoneNoneFalseNoneFalse18644.00
3653999133305None2.3.2Wiring for lighting/power circuit using one of FRLSH PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments ,as per the directions of Engineer in charge of the work. 1.5 SqmmMtr30.6830.68600.0FalseNoneNoneFalseNoneFalse18408.00
3654000133305None2.3.3Wiring for lighting/power circuit using one of FRLSH PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system ofwiringwithspecifiedIS694confirming to latest amendments ,as per the directions of Engineer in charge of the work2.5 SqMtr49.5649.561100.0FalseNoneNoneFalseNoneFalse54516.00
3654001133305None2.3.4Wiring for lighting/power circuit using one of FRLSH PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:confirming to latest amendments ,as per the directions of Engineer in charge of the work.4 SqmmMtr74.3474.34400.0FalseNoneNoneFalseNoneFalse29736.00
3654002133305None2.2.1Point wiring using copper wire with out switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmmEarthwireFRLSH multi strand PVC insulated copper wire confirming to IS694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. as per the directions of Engineer in charge of the work. Short point upto 3Mtr. from tapping point to out let via switch.Point317.42317.4212.0FalseNoneNoneFalseNoneFalse3809.040
3654003133305None2.2.2Point wiring using copper wire with out switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm Earth wire FRLSH multi strand PVC insulated copper wire confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. as per the directions of Engineer in charge of the work.Medium point above 3Mtr. Upto 6Mtr. from tapping point to out let via switchPoint447.22447.2255.0FalseNoneNoneFalseNoneFalse24597.10
3654004133305None2.2.3Point wiring using copper wire with out switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSH multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. as per the directions of Engineer in charge of the ong point above 6Mtr. Upto 10Mtr. from tapping point to out let via switchPoint654.9654.932.0FalseNoneNoneFalseNoneFalse20956.80
3654005133305NoneEle SR 14-15 Item No-4.2.2Supplying and fixing PBBC bakelite straight or slant batten holder and wiring, within 60w230 Volts lamps.No83.7883.7850.0FalseNoneNoneFalseNoneFalse4189.00
3654006133305NoneSR 1415 Item No4.4Suppying and fixing cast Aluminium round or ablong type LED 10 watts bulk head fitting suitable for operation of 220 to 240 Volts with burning hours 25 to 50,000 ,as per the directions of Engineer in charge of the work.Each1123.361123.362.0FalseNoneNoneFalseNoneFalse2246.720
3654007133305None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200mm). and as per the directions of Engineer in charge of the work. Rated air delivery 210 +/- 10% CMM(Cubic Meters per Minute).Each3521.123521.1224.0FalseNoneNoneFalseNoneFalse84506.880
3654008133305None13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring ,as per the directions of Engineer in charge of the work.Each201.78201.7824.0FalseNoneNoneFalseNoneFalse4842.720
3654009133305None6.1Supplying exhaust fan of 1440 RPM of 300 mm(12') size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply, ,as per directions of engineer incharge of the work.Each1760.561760.568.0FalseNoneNoneFalseNoneFalse14084.480
3654010133305None13.14Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. Ceiling rose wisth sufficient length of 23/0.0076 inch PVC insulated twincore wire ,as per directions of engineer incharge of the work.Each580.56580.568.0FalseNoneNoneFalseNoneFalse4644.480
3654011133305None11.32Supplying of .feet -PVC Batten with integrated LED tube withhi quality diffuser with Life of 25000 burning hours &70lummaintenance with CRI80. Power Input: 220-240V 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against anymanufacturingdefect working under standard electrical condition. LED light fitting 1 x 4' 2022 W11Each814.2814.215.0FalseNoneNoneFalseNoneFalse12213.00
3654012133305None11.3.3supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70lumenmaintenance withCRI80.PowerInput:220240V5060HzPowerfactor0.9alongwithCEapproved.2yearsWarrantyagainstanymanufacturing defect working under standard electrical condition LED liightfittinNo1497.421497.4225.0FalseNoneNoneFalseNoneFalse37435.50
3654013133305None13.7.1Fixing all types and all capacities of LED light fittings indoor on the wall / ceilingrafters / girders using 23/0.00 76” twin twisted PVC insulated wires, required Nos of round blocks , holder with adopter and clamps. Onwall/ceiling/Rafter/Girders ,as per the directions of Engineer in charge of the work.No143.96143.9642.0FalseNoneNoneFalseNoneFalse6046.320
3654014133305None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wireSet4141.84141.82.0FalseNoneNoneFalseNoneFalse8283.60
3654015133305None12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts ,as per directions of engineer incharge of the work.Each5022.085022.082.0FalseNoneNoneFalseNoneFalse10044.160
3654016133305NoneEle SR 2019-20 6.3.1Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required ,as per directions of engineer incharge of the work.GI strip 25x3mmMtr88.588.520.0FalseNoneNoneFalseNoneFalse1770.00
3654017133305None12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. copper strip 25x3mmEach672.6672.625.0FalseNoneNoneFalseNoneFalse16815.00
3654018133305NoneMR Supplying and fixing Lightining arester spike as per the directions of Engineer in charge of the work.Marc5900.05900.01.0FalseNoneNoneFalseNoneFalse5900.00
3654019133305None12.58.11Supplying and running of Copper strips for grounding connections, using necessary fixing materials as required. Copper strip f) 600 x 600 x 3mm copper plate as per the directions of Engineer in charge of the work.Each8756.788756.782.0FalseNoneNoneFalseNoneFalse17513.560
3654020133305None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,as per the directions of Engineer in charge of the work. i) 1-3WayEach187.62187.6240.0FalseNoneNoneFalseNoneFalse7504.80
3654021133305None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in ick/Stone/C.C wall ,as per the directions of Engineer in charge of the work. ii) 4-5WayEach208.86208.8610.0FalseNoneNoneFalseNoneFalse2088.60
3654022133305None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in /Stone/C.C wall ,as per the directions of Engineer in charge of the work. ii) 6WayEach259.6259.610.0FalseNoneNoneFalseNoneFalse2596.00
3654023133305None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in wall ,as per the directions of Engineer in charge of the work. iii) 8WayEach307.98307.9845.0FalseNoneNoneFalseNoneFalse13859.10
3654024133305None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in ick/Stone/C.C wall ,as per the directio ns of Engineer in charge of the work. iii) 10-12 WayEach376.42376.425.0FalseNoneNoneFalseNoneFalse1882.10
3654025133305None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box ,as per the directions of Engineer in charge of the work. i)1 to 3 ModuleEach189.98189.9840.0FalseNoneNoneFalseNoneFalse7599.20
3654026133305None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. and as per the directions of Engineer in charge of the work. ii) 4 ModuleEach206.5206.510.0FalseNoneNoneFalseNoneFalse2065.00
3654027133305None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. and as per the directions of Engineer in charge of the work. iii) 6 ModuleEach276.12276.1210.0FalseNoneNoneFalseNoneFalse2761.20
3654028133305None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. and as per the directions of Engineer in charge of the work. iv) 8 ModuleEach335.12335.1245.0FalseNoneNoneFalseNoneFalse15080.40
3654029133305None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. and as per the directions of Engineer in charge of the work. iv) 10-12 ModuleEach405.92405.925.0FalseNoneNoneFalseNoneFalse2029.60
3654030133305None3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. i) 6 Amps one way switchEach120.36120.36160.0FalseNoneNoneFalseNoneFalse19257.60
3654031133305None3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. iv) b) 16 Amps one way switchEach212.4212.425.0FalseNoneNoneFalseNoneFalse5310.00
3654032133305None3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. ii) 6 Amps 3 way socketEach201.78201.78115.0FalseNoneNoneFalseNoneFalse23204.70
3654033133305None3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. iv) d) 6/16 Amps universal socketEach278.48278.486.0FalseNoneNoneFalseNoneFalse1670.880
3654034133305None3.6.12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. l) RJ45/I.O. outletEach397.66397.6630.0FalseNoneNoneFalseNoneFalse11929.80
3654035133305None3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. v) Stepped Fan RegulatorEach421.26421.2624.0FalseNoneNoneFalseNoneFalse10110.240
3654036133305None3.6.11Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. and as per the directions of Engineer in charge of the work. vi) TV socketEach184.08184.082.0FalseNoneNoneFalseNoneFalse368.160
3654037133305None3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in charge of the work. 32Amps DP switchEach384.68384.686.0FalseNoneNoneFalseNoneFalse2308.080
3654038133305NoneNSRSupplying and fixing Cordless calling bell suitable to operte on 230V 50Hz AC/ 3V DC Supply, cordless remote bell push with 2x1.5V DC Batteris and completely wired and as per the directions of Engineer in charge of the work.Each767.0767.02.0FalseNoneNoneFalseNoneFalse1534.00
3654039133305NoneBescom SR 23-24 32.07Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 a) 3.5 core 25 sqmmMtr164.66164.66120.0FalseNoneNoneFalseNoneFalse19759.20
3654040133305NoneBescom SR 23-24 32.05Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 a) 4 core 16 sqmmMtr167.37167.3780.0FalseNoneNoneFalseNoneFalse13389.60
3654041133305NoneBescom SR 23-24 21.05Labour charges for Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff a) 2.5 sqmm to 25 sqmmMtr24.6424.64120.0FalseNoneNoneFalseNoneFalse2956.80
3654042133305NoneBescom SR 23-24 21.06Labour charges for laying of 1.1 KV class UG cable when supplied agency stoneware pipe / on wall / on pole as required. In exixting trench/duct. 35 sqmm to 95 sqmm as per the directions of Engineer in charge of the work. Mtr36.7336.7380.0FalseNoneNoneFalseNoneFalse2938.40
3654043133305NoneEle SR 2019-20 6.10.3Supplying and fixing L.T. cast Iron pot heads suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps, bolts, nuts anwashers etc. 1) 25 SqmmEach413.0413.02.0FalseNoneNoneFalseNoneFalse826.00
3654044133305NoneEle SR 2019-20 6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) as per the directions of Engineer in charge of the work.Mtr89.6889.6875.0FalseNoneNoneFalseNoneFalse6726.00
3654045133305NoneEle SR 2019-20 6.9.1Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class. and as per the directions of Engineer in charge of the work. 1) 40 mmMtr395.3395.310.0FalseNoneNoneFalseNoneFalse3953.00
3654046133305NoneEle SR 2019-20 .7.20.3Supplying and Laying double walled corrugatted HDPE Pipe in cluding alll accessoriesMtr253.7253.760.0FalseNoneNoneFalseNoneFalse15222.00
3654047133305None5.42.2Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with suitable approved colour powder coated paint ,as per directions of engineer incharge of the work. 1) 16 SWGSq CM0.50.540000.0FalseNoneNoneFalseNoneFalse20000.00
3654048133305None5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint ,as per directions of engineer incharge of the work. b) 40x40x6mmMtr359.9359.98.0FalseNoneNoneFalseNoneFalse2879.20
3654049133305None5.40.2Supplying .250. amps rated 3phase with neutral bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers ,as per directions of engineer incharge of the work. a) 250 Amps 4x30x10mm Aluminium StripsMtr4053.34053.30.5FalseNoneNoneFalseNoneFalse2026.650
3654050133305None5.11.2Supplying of on load change over over switches 4 poles, AC 23Amps duty 415V, 50HZ, AC Supply ,as per directions of engineer incharge of the work. 100AmpsEach8366.28366.21.0FalseNoneNoneFalseNoneFalse8366.20
3654051133305None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism ,as per directions of engineer incharge of the work.a)100 Amps 25kAEach10014.6610014.661.0FalseNoneNoneFalseNoneFalse10014.660
3654052133305None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C 50Hz 12/24v D.C ,as per the directions of Engineer in charge of the work.Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3654053133305None5.29Supplying, fixing and wiring 3 phase Digital Ammeter/ Voltmeter ,as per directions of engineer incharge of the work.Each1681.51681.52.0FalseNoneNoneFalseNoneFalse3363.00
3654054133305None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.,as per the directions of Engineer in charge of the work. 6-32Amps SPNo489.7489.715.0FalseNoneNoneFalseNoneFalse7345.50
3654055133305None15.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.,as per the directions of Engineer in charge of the work. 6-32Amps DPEach872.02872.026.0FalseNoneNoneFalseNoneFalse5232.120
3654056133305None15.18.7Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.,as per the directions of Engineer in charge of the work. 6-32Amps TPNEach2026.062026.063.0FalseNoneNoneFalseNoneFalse6078.180
3654057133305None15.19.9Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure 1) Double Door 12 Way SP &N and as per the directions of Engineer in charge of the workEach2748.222748.224.0FalseNoneNoneFalseNoneFalse10992.880
3654058133305None15.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16-25 Amps 2 pole and as per the directions of Engineer in charge of the workEach5046.865046.864.0FalseNoneNoneFalseNoneFalse20187.440
3654059133305None11.6.3Supply of LED Streetlight 70w luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated lifeEach7070.567070.564.0FalseNoneNoneFalseNoneFalse28282.240
3654060133305None13.1.2Supplying and Fixing of …….mm dia class A GI pipe bracket up to 2 mtrs long bent at suitable angle and fixing to this bracket 1 x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CL or rail or RCC pole/wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires Using 32mm dia G.I.Pipe, ,as per directions of engineer incharge of the work.Each1233.11233.14.0FalseNoneNoneFalseNoneFalse4932.40
3654061133305None11.6.3Supplying of recess mounting non integral type 36watt luminaire comprising of pressureEach5372.545372.542.0FalseNoneNoneFalseNoneFalse10745.080
3654062133305None11.11.7Supplying & fixing of retrofit type - LED bulb 18 W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI70efficacy 80 lumen per watt, life25000 burning hours and Compliance to IS 1032No502.68502.6820.0FalseNoneNoneFalseNoneFalse10053.60
3654063133305None8.1Supply& Laying of UTP cat-6E LAN cable and as per the directions of Engineer in charge of the work.Mtr44.8444.841400.0FalseNoneNoneFalseNoneFalse62776.00
3654064133305None8.2.2Supplying and drawing PVC flexible one pair telepone unarmoured tinned copper cable. 2 pair and as per the directions of Engineer in charge of the work.Mtr24.7824.78120.0FalseNoneNoneFalseNoneFalse2973.60
3654065133305None8.4.2Supplying & Fixing of switch mounting rack with power manager & Cable manage 6U with 450mm depthEach8232.868232.862.0FalseNoneNoneFalseNoneFalse16465.720
3654066133305None8.9.6Supplying fixing of Network Switches. 16 port Switch and as per the directions of Engineer in charge of the work.Nos2891.02891.01.0FalseNoneNoneFalseNoneFalse2891.00
3654067133305None8.9.2Supplying fixing of Network Switches. port24 Port Gigabyte (manageable) and as per the directions of Engineer in charge of the work.Nos48911.048911.01.0FalseNoneNoneFalseNoneFalse48911.00
3654068133305None8.12.2Supplying & Fixing of Patch panel for LAN cabling 24 port 10/100 patch panel and as per the directions of Engineer in charge of the work.Nos4838.04838.02.0FalseNoneNoneFalseNoneFalse9676.00
3654069133305None8.10.2Supplying & fixing of I/O socket with back box, Double I/oEach649.0649.025.0FalseNoneNoneFalseNoneFalse16225.00
3654070133305None15.3Supply, installation of 4kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 6.9 Kg, empty weight 2.9 Kg, Can Height 440MM, Diameter 140MM, Discharge Time less than 13 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8, C and electrically started Fire, A Rating 2A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded,valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with installation system with Superiorquality EPDM Rubber Hosepipe etc., including cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall, , labour, usage charges of machinerycomplete as per specifications. complete IS 15683, CE Approved. and as per the directions of Engineer in charge of the work.Set3127.03127.02.0FalseNoneNoneFalseNoneFalse6254.00
3654071133305NoneCIVIL SRSupplying of 1 HP Open well Mono sub pump set suitable for operation on 230 volts 2880 RPM single phase AC supply And as per the directions of engineer incharge of the work.Set10782.8410782.841.0FalseNoneNoneFalseNoneFalse10782.840
3654072133305NoneNSRSupplying of 50 mm kirloskar / other approved make CI screwed foot valve, as per the directions of engineer incharge of the work.Nos531.0531.01.0FalseNoneNoneFalseNoneFalse531.00
3654073133305None5.1Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 volts 1/3 phase motor upto 5 HP.Each2273.862273.861.0FalseNoneNoneFalseNoneFalse2273.860
3654074133305NoneCivil SR 21-22 pg No 13.6 P130FProviding, supplying to work site, Submersible Pump Set 5 HP 15 stageof 150mm dia suitable for bore well and confirming to IS80342000;3Phase, SS Bowl& Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions oSet42421.042421.01.0FalseNoneNoneFalseNoneFalse42421.00
3654075133305NoneCivil SR 21-22 P360AVLabour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per nstructions of engineer incharge of workSet7257.07257.01.0FalseNoneNoneFalseNoneFalse7257.00
3654076133305NoneCivil SR 18-19 Sl No. 13.37KSRB 13-6.3-: Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) NB including cost of all materials, labour and HOM of equipments with all leads complete as per specifications ,as per the directions of Engineer in charge of the workEach2052.022052.021.0FalseNoneNoneFalseNoneFalse2052.020
3654077133305NoneCivil SR 18-19 Sl No. 13.62KSRB13-7.2: Providing and fixing in position 50 mm nominal bore non-return valve vertical type of approved make including cost of all materials, labour and HOM of equipments with alll leads complete as per specifications ,as per the directions of Engineer in charge of the work.Each1497.421497.421.0FalseNoneNoneFalseNoneFalse1497.420
3654078133305NoneCivil SR 21-22 P280ASupply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter for outdoor Upto 6 HP pumpsSet14750.014750.01.0FalseNoneNoneFalseNoneFalse14750.00
3654079133305None2.6.2Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to IS:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100Volts as per IS-694:1990. 3C X 4.0Sq.mm as per the directions of the engineer in charge of the work.Rmtr198.24198.24200.0FalseNoneNoneFalseNoneFalse39648.00
3654080133305NoneCivil SR 2018-19Providing and fixing in trenches galvanised/ mildsteel tubes 50mm dia nominal bore with all fittings including cost of all materials and labour charges and HOM of equipments and testing complete asperspecificationand as per the directions of Engineer in charge of the work.Mtr604.16604.16150.0FalseNoneNoneFalseNoneFalse90624.00
3654081133305None5.7.3Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 63Amps and as per the directions of Engineer in charge of the work.Nos473.18473.186.0FalseNoneNoneFalseNoneFalse2839.080
3654082133305NoneBescom SR 2023-224 1.01Supplying 9 Mtr RCC Pole 145Kg WL. including earth work etc,. Complete as per the standard technical specification., 9 Mtr 145Kg WL. (Dwg No GM/QS&S/02 Dtd 24.11.2018) as per IS-785 ,as per the directions of Engineer in charge of the work.Each8349.688349.681.0FalseNoneNoneFalseNoneFalse8349.680
3654083133305NoneBescom SR 2023-24 2.05Supplying of L.T.4 Pin cross arms, with pole clamps, bolts, nuts and washers (for RCC poles)Set341.02341.022.0FalseNoneNoneFalseNoneFalse682.040
3654084133305NoneBescom SR 2023-24 7.02Supplying of Rabbit ACSR Conductor with 1.5% sag.and as per the directions of Engineer in charge of the workKm54556.1254556.120.3FalseNoneNoneFalseNoneFalse16366.8360
3654085133305NoneBescom SR 18-19Fixing of guy set with guy wire, guyrod and break insulators etc complete set and as per the directions of Engineer in charge of the work.Nos206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
3654086133305NoneBescom SR 2023-24 2.02Erection of RCC/PSC poles 9 to 10 mtr long but in a pit of 1.8 mtr depth with consoldation etc, complete ,as per the directions of Engineer in charge of the workNos1313.341313.341.0FalseNoneNoneFalseNoneFalse1313.340
3654087133305NoneBescom SR 2023-24 5.02Fixing of 4 Pin cross arm with insulator and Braces fixing and as per the directions of Engineer in charge of the work.Set188.8188.82.0FalseNoneNoneFalseNoneFalse377.60
3654088133305NoneBescom SR 2023-24 7.02Stringing of No.1 ACSR Rabbit conductor with 1.5% sag and as per the directions of Engineer in charge of the work.Kms6174.946174.940.3FalseNoneNoneFalseNoneFalse1852.4820
3654089133305None9.3.3Supplying, erecting, testing & commissioning of 5 KVA ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories one hour back up complete and Excluding batteries and wiring complete. 5 KVASet80691.9480691.942.0FalseNoneNoneFalseNoneFalse161383.880
3654090133305None9.4.3Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene contain 75 AH CAPACITYEach20542.6220542.6224.0FalseNoneNoneFalseNoneFalse493022.880
3654091133305None11.7.1Supply of LED pole mounting type post top lantern LED Post Top Lantern with 15/20 W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light outputRated lifE Burning Hrs 50000 hr@ Lumen Maintenance of 70%,No8167.968167.962.0FalseNoneNoneFalseNoneFalse16335.920
3654092133305None13.6Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI / GI or any other pipe using required size of reducer, wiring using suitable wiresEach233.64233.642.0FalseNoneNoneFalseNoneFalse467.280
3654093133305NoneApproved rates Supply of erection testing and commissioning of water level controller and connected accessoriers etc.Nos11800.011800.01.0FalseNoneNoneFalseNoneFalse11800.00
3654094133305None2.5.4Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 6C x 1.5 mm2Mtr142.78142.7850.0FalseNoneNoneFalseNoneFalse7139.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17224047910000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17224047910000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17224047910002NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of karnataka public procurement portal due to internet connectivity issues and technical glitches at bidder s end.None
17224047910000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17224047910000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17224054510000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contract value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17224054610000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17224054730000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if anyNone
17224054830000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the rates.None
17224054960000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose onlyNone
17224055050000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KSPH & IDCL have the right to deduct the work bills and remit the same to respective PF offices.None
17224055190000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to time and if any variation occurs it shall be paid / refunded by / to the Corporation against documentary evidenceNone
17224055440000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund ActNone
17224055660000NoneNoneELIGIBILITYRemittance towards PF shall be commensurate with the labour component of the work involved.None
17224055870000NoneNoneELIGIBILITYThe Bidder shall remit PF of labourers to Bidders permanent PF code number onlyNone
17224056100000NoneNoneELIGIBILITYThe bidder should maintain register of labourers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17224056210000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17224056340000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the karnataka public procurement portal and www.ksphc.org web sites only.None
17224056630000NoneNoneELIGIBILITYBounded scanned hard copies are to be submitted duly marking the Page Nos. within 3 days after the last date of submission of the bid documents online to EE(Contracts), KSPH & IDCL, Bangalore.None
17224057740001NoneNoneELIGIBILITYThe rates quoted by the Contractor shall be deemed to be inclusive of all applicable taxes, GST, levies, duties and cess, Building Workers Welfare Cess etc., as applicable as per the latest Notifications of GoK and GoI prevailing as on the date of NIT. The Employer will perform such duties in regard to the deduction of such taxes at source as per applicable law. The Contractor should submit the tax invoice along with RA Bills.None
17224057870000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer(Contracts), KSPH & IDCL, Richmond Road, Bangalore 560025. Ph: 080-25584102 Extn - 130 / 114 / 117None
17224058050000NoneNoneELIGIBILITYThe bidder should furnish the documents relating to registration of GSTNone
17224058410000NoneNoneELIGIBILITYThe bidder should furnish the valid address, phone number & e mail IDNone
17224058510000NoneNoneELIGIBILITYThe intended bidder shall visit the site & quote his offer accordingly and for having visited the site, they should upload the photos while submitting the tender.None
17224065810000NoneNoneELIGIBILITYTenders must be accompanied by Earnest Money Deposit (EMD) of Rs. 1.99 Lakhs (Rupees One Lakh Ninety Nine Thousand only), which may be paid fully through Karnataka Public Procurement Portal or Out of total EMD amount Rs. 1.00 lakh (Rupees One Lakh only) shall be paid online through Karnataka Public Procurement Portal using any of the following Payment Modes: Credit Card, Direct Debit, National Electronic Fund Transfer (NEFT), Over the Counter (OTC) and the balance amount of Rs. 99,000/- (Rupees Ninety Nine Thousand only) in the form of Bank Guarantee (BG) only issued from Nationalized/Scheduled Commercial Banks in the Name of MD, KSPH&IDCL, Bengaluru. The scan copy of the Bank Guarantee (BG) to be uploaded at the time of submission of bid documents and the original Bank Guarantee should be submitted to Office of the Executive Engineer (Contracts), KSPH & IDCL, No.59, Gen. K.S. Thimmayya Road, Bangalore 560025 On or before the Last date of receipt of tender and the non-compliance of the same leads to the rejection of the bid.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNone1.3 of Section-3 Qualification Information: Work performed as Prime Contractor (in the same name) on works of similar nature over during the five years (2019-20 to 2023-24)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The scanned original work experience certificate issued by not below the rank of Executive Engineer
NoneNoneNoneNone1.4 of Section-3 : Quantities of work executed as prime contractor (in the same name) during the last five years (2019-20 to 2023-24)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The scanned original work experience certificate issued by not below the rank of Executive Engineer
NoneNoneNoneNone1.5 of Section-3 Qualification Information : Information on works for which Tenders have been submitted and works which are yet to be completed as on the date of this Tender : (A) Existing commitments and ongoing works & (B) Works for which Tenders already submittedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The scanned original work experience certificate issued by not below the rank of Executive Engineer
NoneNoneNoneNone1.7 of Section-3: Qualification Information: Reports on the financial standing of the tenderer, such as profit and Loss statements and auditors reports for the last five years. (2019-20 to 2023-24)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Profit & Loss Statement from Registered Chartered Accountant
NoneNoneNoneNone3.2- To qualify for award of this contract, each Tender in his/her/their name should have in the last five years i.e. 2019-20 to 2023-24): (b) Satisfactorily completed as prime contractor (at least 90% of the contract value), at least one similar nature of work of value not less than Rs.66.31 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work Done certificate issued not below the rank of an Executive Engineer or equivalent.
NoneNoneNoneNoneITT - 3.2 d) The Tenderer or his identified sub-contractor should possess required valid electrical license for executing building electrification works and should have executed similar electrical works totalling Rs.8.50 Lakhs in any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Workdone certificate issued not below the rank of an Executive Engineer. In case of Sub Contractor licence & Consent letter also to be uploaded.
NoneNoneNoneNone3.2 (e) The Tenderer or his identified subcontractor should possess valid license for executing water supply/sanitary engineering works and should have executed similar water supply/sanitary engineering works totaling Rs.2.42 Lakhs in any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Workdone certificate issued not below the rank of an Executive Engineer. In case of Sub Contractor licence & Consent letter also to be uploaded.
NoneNoneNoneNoneBe a Class-III & above Civil registered contractor of State PWDs / Central/MES/ Govt. UndertakingsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Valid Registration Certificate issued by respective Depts
NoneNoneNoneNoneBe Registered with KSPH & IDCLCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Valid Registration Certificate issued by KSPHCL
NoneNoneNoneNoneIncome Tax returns & PANCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Income Tax returns and PAN certificates
NoneNoneNoneNoneBe Registered with GSTCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Valid Registration Certificate issued by Competent Authority
NoneNoneNoneNoneBe Registered with EPF AuthoritiesCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- EPF Registration Certificate
NoneNoneNoneNoneITT 3.2 - To qualify for award of this contract, each Tenderer / company in his / its name should have in the last five years i.e. 2019-20 to 2023-24 (c) Executed in any one year the minimum quantities of work executed (Please refer Tender Document)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued from not below the rank of an Executive Engineer or equivalent.
NoneNoneNoneNoneITT 3.3 (c)- Each Tenderer should further demonstrate Liquid assets and /or availability of credit facilities of no less than Rs.36.20 Lakhs (Credit lines/ letter of credit/ certificates from Nationalized / Scheduled banks for meeting the fund requirement etc (Unconditional)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Letter of Credit Certificates from Nationalized / Scheduled banks for meeting the fund requirement
NoneNoneNoneNoneITT 3.2 - To qualify for award of this contract, each Tenderer in his/her/their name should have in the last five years i.e. 2019-20 to 2023-24: (a) Achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs.265.30 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach Certificate from Registered Chartered Accountant with UDIN Number
NoneNoneNoneNone1.8 of Section-3 Qualification Information: Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are Proposed to be deployed on this contract, if awarded.OthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Organization Chart & Company Profile
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
KSPH & IDCL Registration CertificateTrueTechnical Bid
Class-III & above Civil registered contractor of State PWDs / Central/MES/Govt. UndertakingsTrueTechnical Bid
Income Tax returns & PANTrueTechnical Bid
EPF Registration CertificateTrueTechnical Bid
Work Done Certificate - ITT 3.2 b Similar nature Work done certificateTrueTechnical Bid
Liquid assets and availability of credit facilitiesTrueTechnical Bid
Turnover Certificate - ITT 3.2 aTrueTechnical Bid
1.3.of Section-3 Qualification InformationTrueTechnical Bid
1.4.of Section-3 Qualification InformationTrueTechnical Bid
1.7.of Section-3 Qualification InformationTrueTechnical Bid
GST Registration CertificateTrueTechnical Bid
Executed minimum quantities of work - ITT 3.2 cTrueTechnical Bid
Work Done Certificate - ITT 3.2 d Electrical Work done certificateTrueTechnical Bid
Work Done Certificate - ITT 3.2 e Water supply /sanitary Work done certificateTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1722503267000
version0
createdDateNone
modifiedDateNone
blockNumberNo. 59, Richmond Road (Gen. K.S.Thimmaiah Road)
streetNone
cityBengaluru
stateKarnataka
pin560025
tenderRecallDTONone