createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1722411475758
version6
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd403000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose31-08-2024 17:30:00
tenderQueryClose22-08-2024 11:00:00
technicalBidOpen02-09-2024 11:00:00
publishedDate01-08-2024 17:25:04
publishedByPostKSPHIDCL_EECNT_CNT_BNG
publishedByUserKPE13762 - SHIVAPRAKASH G
bidValidityPeriod90
noOfCalls1
preBidMeetingDate19-08-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVAPRAKASH G
splitEmdRequiredYnTrue
emdBankGuarantee303000.00
emdCash100000.00
bgValidityPeriod120
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08025584130
mobileNumber7892672609
tenderSupplierListNone
tenderSchedule
createdTs1722411475784
version8
createdDateNone
modifiedDateNone
tenderNumberKSPHIDCL/2024-25/BD/WORK_INDENT120
titleConstruction of 3 Bay Fire Station at Vasanth Narasapura Industrial Area in Tumkur District under K-SAFE-2 Scheme
descriptionConstruction of 3 Bay Fire Station at Vasanth Narasapura Industrial Area in Tumkur District under K-SAFE-2 Scheme
categoryWORKS
categoryTextWorks
ecv26857335.73
deptNameKarnataka State Police Housing and Infrastructure Development Corporation Limited
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location7550
locationNameKSPHIDCL Contracts Section Bengaluru
provisionalAmount30000000.0
groupOverheadTotal0.0
fileNumberPHC/CNT/BNG(R)/TND/20/2024-25/WI-120
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17224114760000NoneNoneBuildingsCONSTRUCTION OF 3 BAY FIRE STATION AT VASANTH NARSAPURA IN TUMKUR DIST22115087.68
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3655835133390NoneCSR 2022 Vol-1, It. No.1.12 Pg No.8Earth work in surface excavation by mechanical means for lowering &leveling the ground for all works other than foundation in all kinds ofsoils & upto depth not exceeding 300mm as per drawing and technicalspecifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter includingdressing of excavated surfaces, disposing off or levelling the excavatedearth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum117.71117.71360.0FalseNoneNoneFalseNoneFalse42375.60
3655836133390NoneCSR 2022 Vol-1, It. No.1.14.1 Pg No.8Earth work excavation for Foundation by mechanical means for allworks & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling theexcavated earth or sorting & stacking the selected earth for reuse in aradius of 50 m and lift upto 1.5 m including cost of labour, tools, usageof machinery & other appurtenaces required to complete the workCum126.38126.38288.0FalseNoneNoneFalseNoneFalse36397.440
3655837133390NoneCSR 2022 Vol-2, It. No.4.1 Pg No.5Providing and injecting chemical emulsion for Pre-constructionalAnti-Termite Treatment, creating continuous chemical barrier underand around the column pits, walls, trenches, basement excavation,top surface of the plinth filling, junction of wall and floor, along theexternal perimeter of building, expansion joints, over the top surface ofconsolidated earth on which apron is to be laid, surrounding of pipesand conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @3.19 l/m2 including cost of chemical, diluting in water to one percentconcentration, labour, usage charges of machinery, complete as perspecifications.Sqm146.2146.2441.0FalseNoneNoneFalseNoneFalse64474.20
3655838133390NoneCSR 2022 Vol-1, It. No.2.1.2 Pg No.15Providing and laying in position plain cement concrete for levellingcourse for all works in foundation. The granite/trap/basalt crushedgraded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost ofall materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formworkshall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum7017.77017.7109.17FalseNoneNoneFalseNoneFalse766122.3090
3655839133390NoneCSR 2022 Vol-II, It. No.5.4 Pg No.9Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum8199.78199.725.68FalseNoneNoneFalseNoneFalse210568.2960
3655840133390NoneCSR 2022 Vol-I, It. No.2.2.2.1 Pg No.15For Footing M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately)Cum8478.338478.33209.66FalseNoneNoneFalseNoneFalse1777566.66780
3655841133390NoneCSR 2022 Vol-I, It. No.2.5.2 Pg No.17For Columns M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately)Cum14413.4114413.4123.26FalseNoneNoneFalseNoneFalse335255.91660
3655842133390NoneCSR 2022 Vol-I, It. No.2.5.2 Pg No.17b) First floorCum14498.214498.220.088FalseNoneNoneFalseNoneFalse291239.84160
3655843133390NoneCSR 2022 Vol-I, It. No.2.5.2 Pg No.17For Roof Slab M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately)Cum12717.7212717.7285.39FalseNoneNoneFalseNoneFalse1085966.11080
3655844133390NoneCSR 2022 Vol-I, It. No.2.5.2 Pg No.17b) First floorCum12802.512802.5111.7FalseNoneNoneFalseNoneFalse1430039.250
3655845133390NoneCSR 2022 Vol-I, It. No.2.5.2 Pg No.17For Roof slab and terrace:Providing and Applying PU based Elastomeric Liquid Applied PUWaterproofing Membrane single component, cold applied, waterbased acrylic PU dispersion with highly elastic and UV resistant waterproofing treatment to the Existing Roof surface/Chajjas/Sunken portionof WC:Bathroom applied @ 1.2L/per m2,having tensile strength greaterthan 1.5N/mm2, elongation greater than 300% with solid content notless than 60% in 2 coats including surface preparation, priming thesurface with water based acrylic primer @0.1 L/m2, and spreading 60gsm geotextile between two top coats completely as per specification.The finished cost to include surface preparation, making coving atJunction, Bore Packing, treatment of construction joints completely asper specification & with a 10 years warranty on product & work fromcertified manufacturers as per the direction of the Engineer In charge.Sqm913.14913.14474.81FalseNoneNoneFalseNoneFalse433568.00340
3655846133390NoneCSR 2022 Vol-I, It. No.1.9 Pg No.7KSRB 2.3 : Filling available excavated Earth (excluding rock) in sides of foundations upto plinth in layers not exceeding 20 cm in depth , compacting each deposited layers by ramming after watering with lead upto 50 m & lift upto 1.5 m including cost of all labour complete as per specifications.Cum329.57329.571766.1FalseNoneNoneFalseNoneFalse582053.5770
3655847133390None7 2.12 as per CSR-2018-19KSRB 2.5 : Earthwork excavation ( in deposited soil ) and filling sides of foundation upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50m. and lift upto 1.5 m. including cost of all labour complete as per pecifications.Cum247.94247.94756.9FalseNoneNoneFalseNoneFalse187665.7860
3655848133390NoneCSR 2022 Vol-II, It. No.6.32 Pg No.17Providing and constructing load bearing wall with Solid Concrete blocksof size 400x200x200mm having block density more than 1800kg/m3and minimum compressive strength of 4.00 N/mm2 conforming to IS2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1623.091623.09497.57FalseNoneNoneFalseNoneFalse807600.89130
3655849133390NoneCSR 2022 Vol-II, It. No.6.32 Pg No.17b) First floorSqm1639.321639.32466.13FalseNoneNoneFalseNoneFalse764136.23160
3655850133390NoneCSR 2022 Vol-II, It. No.6.34 Pg No.17Providing and constructing load bearing wall with Solid Concrete blocksof size 400x100x200mm having block density more than 1800kg/m3and minimum compressive strength of 4.00 N/mm2 conforming to IS2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1367.861367.86127.22FalseNoneNoneFalseNoneFalse174019.14920
3655851133390NoneCSR 2022 Vol-II, It. No.6.34 Pg No.17b) First floorSqm1381.531381.5399.0FalseNoneNoneFalseNoneFalse136771.470
3655852133390NoneCSR 2022 Vol-I, It. No.2.1.4 Pg No.15Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesProviding and laying in position plain cement concrete for levellingcourse for all works in foundation. The granite/trap/basalt crushedgraded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of ball materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Cum7420.377420.373.4FalseNoneNoneFalseNoneFalse25229.2580
3655853133390NoneCSR 2022 Vol-I, It. No.2.1.4 Pg No.15b) First floorCum7494.577494.576.92FalseNoneNoneFalseNoneFalse51862.42440
3655854133390NoneCSR 2022 Vol-I, It. No.2.5.2 Pg No.17KSRB 4.2.10 : Providing & laying in position reinforced cement concrete of mix (M25) with OPC cement @ 24kgs, with12 mm and down size graded granite metal, machine mixed, well compacted for plain chejja of 7.5 cms. average thickness, upto ground floor level, including cost of all materials, labour, HOM of machinery, finishing, curing, complete as per specifications. Specification no. KBS 4.1, 4.6Cum12293.7912293.792.87FalseNoneNoneFalseNoneFalse35283.17730
3655855133390NoneCSR 2022 Vol-II, It. No.8.16.4 Pg No.44b) First floorCum12378.5812378.581.12FalseNoneNoneFalseNoneFalse13864.00960
3655856133390NoneCSR 2022 Vol-II, It. No.8.16.4 Pg No.44Providing 12 mm thick plain cement mortar bands in cement mortar1:4 (1 cement : 4 fine sand): Moulded Band including rounding offcorners wherever required smooth rendering, providing and removingscaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.m9.919.9173.21FalseNoneNoneFalseNoneFalse725.51110
3655857133390NoneCSR 2022 Vol-II, It. No.8.83 PgKSRB 4-5 : Providing lath plaster with cement mortar 1:3, 5 cms thick with 6 mm dia mild steel bars at 20 cms c/c both horizontally and vertically fixing chicken mesh for drop chejja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work HOM of machineries, curing complete as per specifications for drop chejja.Sqm1533.881533.8821.0FalseNoneNoneFalseNoneFalse32211.480
3655858133390NoneCSR 2022 Vol-I, It. No.2.5.2 Pg No.17Providing RCC loft(atta) 7.5cms thick with cement concrete M25 using clean granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre to centre as per design including formwork,centring,curing,finishing the exposed faces with cement mortar (1:3) etc., complete (exclusive of cost of steel and fabrication charges).Sqm12378.5812378.583.34FalseNoneNoneFalseNoneFalse41344.45720
3655859133390NoneCSR 2022 Vol-I, It. No.2.5.2 Pg No.17b) First floorSqm12378.5812378.585.2FalseNoneNoneFalseNoneFalse64368.6160
3655860133390NoneCSR 2022 Vol-II, It. No.9.29 Pg No.64Providing and laying flooring and steps fine dressed granite stone slabs40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed withcement mortar 1:3 over existing cement concrete bed , including costof materials, mortar, labour, curing complete as per specificationsSqm5335.135335.1359.4FalseNoneNoneFalseNoneFalse316906.7220
3655861133390NoneCSR 2022 Vol-II, It. No.9.29 Pg No.64Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly cement concreteM25 including CM 1:3 plaster finishing,curing etc., complete (excluding the cost of steel and fabrication charges)Sqm12293.7912293.792.16FalseNoneNoneFalseNoneFalse26554.58640
3655862133390NoneCSR 2022 Vol-I, It. No.2.5.2 Pg No.17Providing Salwood frames of doors, windows, clerestory windows,ventilators and other frames, wrought, framed or assembled includingmaking plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specificationsCum122431.79122431.790.88FalseNoneNoneFalseNoneFalse107739.97520
3655863133390NoneCSR 2022 Vol-II, It. No.12.13.1 Pg No.100b) First floorCum122431.79122431.790.51FalseNoneNoneFalseNoneFalse62440.21290
3655864133390NoneCSR 2022 Vol-II, It. No.12.13.1 Pg No.100Fixing of door frame in an existing opening including embedding frame infloor and walls after cutting masonry for holdfasts for embedding holdfastin cement concrete 1:3:6 of 20mm and down size granite metal paintingtwo coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with leadupto 50 m. including cost of materials, labour charges, complete asper specifications.Nos1258.821258.8215.0FalseNoneNoneFalseNoneFalse18882.30
3655865133390NoneCSR 2022 Vol-II, It. No.12.51 Pg No.105b) First floorNos1271.411271.4110.0FalseNoneNoneFalseNoneFalse12714.10
3655866133390NoneCSR 2022 Vol-II, It. No.12.51 Pg No.105do 30 mm thick Both side teak Providing and fixing flush door shutter made out of solid core blockboard type, well seasoned , chemicaly treated hard wood battens andinternal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquidphenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per spcification.Sqm5752.685752.6813.44FalseNoneNoneFalseNoneFalse77316.01920
3655867133390NoneCSR 2022 Vol-II, It. No.12.57.1 Pg No.106b) First floorSqm5752.685752.687.92FalseNoneNoneFalseNoneFalse45561.22560
3655868133390NoneCSR 2022 Vol-II, It. No.12.57.1 Pg No.106Flush door shutter (Inside doors) 32mm thick both side teakSqm4503.774503.776.12FalseNoneNoneFalseNoneFalse27563.07240
3655869133390NoneCSR 2018-19b) First floorSqm4548.814548.818.28FalseNoneNoneFalseNoneFalse37664.14680
3655870133390NoneCSR 2018-20Providing & fixing of 2.5 track x 2-panel sliding windows made outof multi chambered UPVC(Matching to RAL-9016) sections and withminimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo PlasticElastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.The outer frame having an overall size of 81mm width x 42mmheight withreinforcement of 1mm thickness and Sash with overall size of 31mm x57mm and mesh sash of size with GI reinforcement of 1.5mmthickness.CoextrudedGlazing bead for fixing of glass shall be of size 21.5mm x9.5mm. Windows shall be provided with 5mm plain float glass, standardhardware& single point locking system with touch lock. Wall thickness offrame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges forminor T&P's shall not be made)Sqm8116.698116.6921.075FalseNoneNoneFalseNoneFalse171059.241750
3655871133390NoneCSR 2022 Vol-II, It. No.12.89 Pg No.111b) First floorSqm8116.698116.6928.13FalseNoneNoneFalseNoneFalse228322.48970
3655872133390NoneCSR 2022 Vol-II, It. No.12.89 Pg No.111Providing & fixing of louvered ventilator made out of multi chamberedUPVC(Matching to RAL-9016) sections and with minimum TiO2(TitaniumDioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead freewith gaskets -grey colour having isolated drainage and reinforced withGalvanized Iron profile through-out the ventilator frame. The frame havingoverall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on theframe along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7085.847085.842.16FalseNoneNoneFalseNoneFalse15305.41440
3655873133390NoneCSR 2022 Vol-II, It. No.12.85 Pg No.110b) First floorSqm7085.847085.840.72FalseNoneNoneFalseNoneFalse5101.80480
3655874133390NoneCSR 2022 Vol-II, It. No.12.85 Pg No.110Providing and fixing M.S. grills of required pattern in frames of windowsetc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKgs208.15208.15113.4FalseNoneNoneFalseNoneFalse23604.210
3655875133390NoneCSR 2022 Vol-II, It. No.11.34A Pg No.85b) First floorKgs208.15208.15621.0FalseNoneNoneFalseNoneFalse129261.150
3655876133390NoneCSR 2022 Vol-II, It. No.11.34A Pg No.85Providing and supplying aluminium extruded tubular and otheraluminium sections as per the architectural drawings and approveddrawings of Chief Architect, GoK.The aluminium quality shall be as pergrade 6063 T5 or T6 as per BS 1474,including super durable powdercoating of 60-80 microns conforming to AAMA 2604 of required colourand shade as approved by the Engineer-in-Charge. ( The item includescost of material such as cleats, sleeves, screws etc. necessary forfabrication of extruded aluminium frame work. Nothing extra shall bepaid on this account).The weight of aluminium extruded section shallbe taken for purpose of payment.Kgs504.27504.27150.5FalseNoneNoneFalseNoneFalse75892.6350
3655877133390NoneCSR 2022 Vol-II, It. No.18.1 Pg No.222b) Ground floorSqm2273.572273.5758.8FalseNoneNoneFalseNoneFalse133685.9160
3655878133390NoneCSR 2022 Vol-II, It. No.18.2 Pg No.222c) Ground floorSqm3346.543346.5458.8FalseNoneNoneFalseNoneFalse196776.5520
3655879133390NoneCSR 2022 Vol-II, It. No.18.3 Pg No.224KSRB 7.17 : Providing fabricating, assembling and fixing in position, anodised aluminium door, using following aluminium mat finish or glossy finish.Outer frame: plain section: 101.60mm x 44.45mm thickness 3.18mm, section weight 2.404 kg/m, Door Shutter: Vertical section: 44.62 mm x 44.45 mm, thickness 3.18 mm, section weight 1.505 kg/m, Top section: 47.62 mm x 44.45 mm thickness 3.0 mm section weight 1.426 kg/m, Bottom section ; 114.3 mm x 44.45 mm, thickness 3.18 mm, section weight 2.646 kg/m, door central section: 49.91 x 44.45mm thickness 3.00 mm, section weight 1.495 kg/m .Sqm7596.317596.315.4FalseNoneNoneFalseNoneFalse41020.0740
3655880133390None39 7.17.1 CSR-2018-19Providing and fixing of Aluminium composite panel of approved makeand colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level madeout of 50x25x4mm C section or equivalent. The panel should consistof 3mm thick non-halogenated FR grade mineral based polymer ( 2hrs fire resistance as per ASTM E119-12 and clause B, S1, do as perENT 13501-1sandwiched between 0.50 skins thick aluminium sheetmaking a total panel thickness of 4mm. The surfaces will be finishedwith PVDF based coating on topsides and service coating on reversesides would be in polyester paint. The system shall be fixed using GIbrackets, aluminium L cleats and stainless steel bolts and nuts completewith spring washer and cap nuts and all other necessary accessories,sealing shall be done with necessary rods etc., completeSqm4942.374942.3728.0FalseNoneNoneFalseNoneFalse138386.360
3655881133390NoneCSR 2022 Vol-II, It. No.10.15.1 Pg No.71b) First floorSqm4942.374942.3761.0FalseNoneNoneFalseNoneFalse301484.570
3655882133390NoneCSR 2022 Vol-II, It. No.10.15.1 Pg No.71For Celing Providing 6 mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) including rounding off corners wherever requiredsmooth rendering, providing and removing scaffolding, including costof materials, labour, curing complete as per specifications and as perdirections of Engineer-in-chargeSqm264.05264.05261.12FalseNoneNoneFalseNoneFalse68948.7360
3655883133390NoneCSR 2022 Vol-II, It. No.8.4.1 Pg No.41b) First floorSqm264.37264.37492.37FalseNoneNoneFalseNoneFalse130167.85690
3655884133390NoneCSR 2022 Vol-II, It. No.8.4.1 Pg No.41Providing 15 mm cement plaster on the rough side of single or halfbrick wall of mix 1:4 (1 cement: 4 fine sand) including rounding offcorners wherever required smooth rendering, providing and removingscaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm365.51365.51765.16FalseNoneNoneFalseNoneFalse279673.63160
3655885133390NoneCSR 2022 Vol-II, It. No.8.2.1 Pg No.41b) First floorSqm369.16369.16844.24FalseNoneNoneFalseNoneFalse311659.63840
3655886133390NoneCSR 2022 Vol-II, It. No.8.2.1 Pg No.41Providing 15 mm cement plaster on the rough side of single or halfbrick wall of mix 1:4 (1 cement: 4 fine sand) including rounding offcorners wherever required smooth rendering, providing and removingscaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm365.51365.5168.0FalseNoneNoneFalseNoneFalse24854.680
3655887133390NoneCSR 2022 Vol-II, It. No.8.2.1 Pg No.41b) First floorSqm369.16369.1662.0FalseNoneNoneFalseNoneFalse22887.920
3655888133390NoneCSR 2022 Vol-II, It. No.8.2.1 Pg No.41External Plastering Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm438.61438.61674.7FalseNoneNoneFalseNoneFalse295930.1670
3655889133390NoneCSR 2022 Vol-II, It. No.8.3.1 Pg No.41b) First floorSqm438.61438.61847.36FalseNoneNoneFalseNoneFalse371660.56960
3655890133390NoneCSR 2022 Vol-II, It. No.8.3.1 Pg No.41for flagging . Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm438.61438.61353.4FalseNoneNoneFalseNoneFalse155004.7740
3655891133390NoneCSR 2022 Vol-II, It. No.8.3.1 Pg No.41Providing and laying flooring for corridors/lobbies using combination of pre polished 19 mm thick water cut/gang saw Grey Granite, Black Granite, and strips of 50mm wide pre flamed grey granite using pre polished grey granite 19mm thick 76%, Pre polished black granite 19mm thick @ 2% and preflamed 19mm thick grey granite @22% over existing cement concrete bed in CM 1:4 average 20mm thick pointed with white cement/colour pigment etc., complete.Sqm3533.633533.63144.06FalseNoneNoneFalseNoneFalse509054.73780
3655892133390NoneCSR 2022 Vol-II, It. No.9.24 Pg No.63b) First floorSqm3568.963568.9629.19FalseNoneNoneFalseNoneFalse104177.94240
3655893133390NoneCSR 2022 Vol-II, It. No.9.24 Pg No.63Size of Tile 600x600 mm Providing vitrified tiles 60 x 60cms of approved make, shade and size for flooring laid on a bed of 12mm thick cement mortar 1:3 mix, flush pointing with white cemnt using colour pigment, including cost of materials, labour, curing complete as per specification.Sqm1455.831455.83148.22FalseNoneNoneFalseNoneFalse215783.12260
3655894133390NoneCSR 2022 Vol-II, It. No.9.17.2 Pg No.61b) First floorSqm1470.381470.38296.0FalseNoneNoneFalseNoneFalse435232.480
3655895133390NoneCSR 2022 Vol-II, It. No.9.17.2 Pg No.61Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conformingto IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm1101.471101.4728.13FalseNoneNoneFalseNoneFalse30984.35110
3655896133390NoneCSR 2022 Vol-II, It. No.9.11 Pg No.60b) First floorSqm1112.491112.4918.53FalseNoneNoneFalseNoneFalse20614.43970
3655897133390NoneCSR 2022 Vol-II, It. No.9.11 Pg No.60Providing skirting, dadooing, rises of steps with colour glazed tiles6mm thick on 10mm thick cement plaster 1:3 and jointed with whitecement slurry over existing rough plaster surface using glazed tiles ofapproved make and size including cost of materials, labour, completeas per specificationsSqm1284.841284.84110.08FalseNoneNoneFalseNoneFalse141435.18720
3655898133390NoneCSR 2022 Vol-II, It. No.9.39 Pg No.65b) First floorSqm1297.691297.6999.56FalseNoneNoneFalseNoneFalse129198.01640
3655899133390NoneCSR 2022 Vol-II, It. No.9.39 Pg No.65Providing Thermo-Mechanically Treated bars of grade Fe-500D ormore Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacentmembers whereever necessary complete as per Design including costof material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Tonne110837.22110837.2234.82FalseNoneNoneFalseNoneFalse3859352.00040
3655900133390NoneCSR 2022 Vol-II, It. No.11.32 Pg No.84b) First floorTonne111945.6111945.617.4FalseNoneNoneFalseNoneFalse1947853.440
3655901133390NoneCSR 2022 Vol-II, It. No.11.32 Pg No.84Providing applying two coats of wall putty to inside plastered walls and celiing using white cement putty. Scrapping and leveling the surface using steel blade and preparing the surface even and smooth by using different grade sand papers, including cost of all materials, cost of laour and scaffolding etc., complete as per the specification. GFSqm123.9123.91631.16FalseNoneNoneFalseNoneFalse202100.7240
3655902133390None128 15.106 as per CSR-2018-2019Wall painting with acrylic emulsion paint of approved brand andmanufacture to give an even shade :Two coats on new work afterthoroughly brooming the surface to remove all dirt, dust, mortar dropsand foreign matter including preparing the surface even and sand papersmooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm157.35157.351630.79FalseNoneNoneFalseNoneFalse256604.80650
3655903133390NoneCSR 2022 Vol-II, It. No.8.39 Pg No.48KSRB 15-15.2 : Providing and applying painting in two coats with plastic emulsion paint with primer of approved brand on wall surface to give an even approved shade after throughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. KSRB 15-15.2 : Extra over Item 15-15.1 for painting two coats with plastic emulsion paint of approved brand and shade on ceiling and / or sloping roof as per specifications. For CeilingSqm205.67205.67754.0FalseNoneNoneFalseNoneFalse155075.180
3655904133390None119 15.51.2 & 15.51.3Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade :Two coats onnew work over an under coat of suitable shade with ordinary paintof approved brand and manufacture after thoroughly brooming thesurface to remove all dirt, dust, mortar drops and foreign matterincluding preparing the surface even and sand paper smooth, cost ofmaterials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm206.91206.91129.41FalseNoneNoneFalseNoneFalse26776.22310
3655905133390NoneCSR 2022 Vol-II, It. No.8.41 Pg No.48Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 ltr/10 m² over and includingpriming coat of exterior primer applied @ 2.20 kg/10 m²) with paintof approved quality to give an even shade, after thoroughly broomingthe surface to remove all dirt, dust, mortar drops and foreign matterincluding preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directionsof Engineer-in-charge.Sqm215.59215.59757.0FalseNoneNoneFalseNoneFalse163201.630
3655906133390NoneCSR 2022 Vol-II, It. No.8.30 Pg No.46b) First floorSqm217.74217.74849.59FalseNoneNoneFalseNoneFalse184989.72660
3655907133390None117 15.36 as per CSR-2018-19KSRB 15.8.3 Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for paymentRmtr47.0847.08836.0FalseNoneNoneFalseNoneFalse39358.880
3655908133390None15 4.21 as per CSR-2018-19Providing patti 10 cms wide 10 mm thick alround doors, windows ventilators and for parapet and compound wall etc., with cement mortar (1:3) and finished as per design and specification indlucing scaffolding etc., completed (Old SR)Rmtr47.0847.08204.0FalseNoneNoneFalseNoneFalse9604.320
3655909133390None181 24.9 as per CSR-2018-19Painting Kannada and English letterscm4.964.9612000.0FalseNoneNoneFalseNoneFalse59520.00
3655910133390NoneApproved RateInagural StoneNos11800.011800.02.0FalseNoneNoneFalseNoneFalse23600.00
3655911133390NoneCSR 2022 Vol-II, It. No.11.28 Pg No.83Providing and fixing stainless steel 304 grade for staircase railings, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe welded to vertical hollow 50mm dia pipe of 16 guage, stainless steel vertical pipe spaced at 1.20m regular intervals and 5 Nos of 25mm dia stainless steel hollow horizontal pipe are welded to vertical 50mm dia hollow pipe. The entire assembly is fixed to staircase concrete by using expansion bolts by drilling concrete etc., With including all lead, lifts, loading and unloading & HOM charges, all other incidental charges required for completion of work as per approved specifications, designs, drawings etc., complete and directions of the Engineer in-charge of the work., etc., complete as per specifications. (I-7.38)Kgs700.04700.04492.0FalseNoneNoneFalseNoneFalse344419.680
3655912133390NoneCSR 2022 Vol II IT NO 12.96 PG 112Providing and fixing Fibre Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm X 45mm having single rebate of 32mm X 15mm to receive shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be coverd with fibre glass from all sides, M.S.Stay shall be provided at the bottom to steady the frame.Sqm796.68796.686.12FalseNoneNoneFalseNoneFalse4875.68160
3655913133390NoneCSR 2022 Vol II IT NO 12.96 PG 112Providing and fixing Fibre Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm X 45mm having single rebate of 32mm X 15mm to receive shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be coverd with fibre glass from all sides, M.S.Stay shall be provided at the bottom to steady the frame.Sqm789.21789.218.28FalseNoneNoneFalseNoneFalse6534.65880
17224114760000NoneNoneBuildingsCONSTRUCTION OF 3 BAY FIRE STATION AT VASANTH NARSAPURA IN TUMKUR DIST WATER SUPPLY663832.02
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3655914133391NoneCSR 2022 Vol-I, It. No.1.6.1 Pg No.6Earth work excavation for pipelinescables by Manual means upto 600mm trench width, as per drawing and technical specifications, includingsetting out, shoring, strutting, barricading, caution lights, removal ofstumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting& stacking the selected earth for reuse in a radius of 50 m. Fillingavailable excavated earth excluding rock in trenches, plinth, sides offoundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.Cum599.68599.6876.0FalseNoneNoneFalseNoneFalse45575.680
3655915133391NoneCSR 2022 Vol-I, It. No.1.10 Pg No.7Refilling available earth around trenchespipelines, cables in layersnot exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum198.24198.2463.0FalseNoneNoneFalseNoneFalse12489.120
3655916133391NoneCSR 2022 Vol-II It. No.13.33.3Providing & fixing CPVC pipe of dia 25 mmm366.74366.7468.0FalseNoneNoneFalseNoneFalse24938.320
3655917133391NoneCSR 2022 Vol-II It. No.13.33.4Providing & fixing CPVC pipe of dia 32 mm (external)m460.91460.9170.0FalseNoneNoneFalseNoneFalse32263.70
3655918133391NoneCSR 2022 Vol-II, It. No.13.33.5Providing & fixing CPVC pipe of dia 40 mmm591.0591.065.0FalseNoneNoneFalseNoneFalse38415.00
3655919133391NoneCSR 2022 Vol-II, It. No.13.33.5Providing & fixing CPVC pipe of dia 50 mm diam893.32893.3275.0FalseNoneNoneFalseNoneFalse66999.00
3655920133391NoneCSR 2022 PG-115, Vol-II It. No.13.3.1Providing & fixing Brass Bib cocks stop cock of 15mm diaEach370.46370.4615.0FalseNoneNoneFalseNoneFalse5556.90
3655921133391NoneCSR 2022 PG-115, Vol-II, It. No.13.4.2Providing & fixing Brass Gate Valve of 32 mm diaEach740.92740.925.0FalseNoneNoneFalseNoneFalse3704.60
3655922133391NoneCSR 2022 PG-115, Vol-II, It. No.13.4.3Providing & fixing Brass Gate Valve of 40 mm diaEach869.78869.782.0FalseNoneNoneFalseNoneFalse1739.560
3655923133391NoneCSR 2022 PG-115, Vol-II, It. No.13.4.4Providing & fixing Brass Gate Valve of 50 mm diaEach1059.351059.352.0FalseNoneNoneFalseNoneFalse2118.70
3655924133391NoneNSRAC Cowl with CapNos37.1737.174.0FalseNoneNoneFalseNoneFalse148.680
3655925133391NoneCSR 2022 PG-134, Vol-V, It. No.1.5,M010EProviding, laying & jointing PVC pipes75mm dia pipe.m272.58272.5833.0FalseNoneNoneFalseNoneFalse8995.140
3655926133391NoneCSR 2022 PG-134, Vol-V, It. No.1.7,M010GProviding, laying & jointing PVC pipes110mm dia pipe.m509.23509.23106.0FalseNoneNoneFalseNoneFalse53978.380
3655927133391NoneCSR 2022 PG-134, Vol-V, It. No.1.9,M010IProviding, laying & jointing PVC pipes (Oriplast) 160mm dia pipe.m765.7765.750.0FalseNoneNoneFalseNoneFalse38285.00
3655928133391NoneCSR 2022 Vol-II, It. No.14.1.1 Pg No.123Providing Orissa pan with flushing cisternPan6051.06051.07.0FalseNoneNoneFalseNoneFalse42357.00
3655929133391NoneCSR 2022 Vol-II, It. No.14.35.1 Pg No.129Providing water closet European type with flushing cisternEach10695.0510695.054.0FalseNoneNoneFalseNoneFalse42780.20
3655930133391None90 12.112.2 as per CSR-2018-19Providing stone ware gully trap nahani trap of approved Quality 15cmx10cmEach428.69428.694.0FalseNoneNoneFalseNoneFalse1714.760
3655931133391None9012.113.1 as per CSR-2018-19Providing & fixing CI Nahani trap of approved QtyEach272.58272.5810.0FalseNoneNoneFalseNoneFalse2725.80
3655932133391NoneCSR 2022 Vol-II, It. No.14.4.1 Pg No.123Providing urinal basin with flushing systemEach5518.515518.516.0FalseNoneNoneFalseNoneFalse33111.060
3655933133391None26937.35 as per CSR-2018-19Providing Wall bores in BBMEach130.1130.132.0FalseNoneNoneFalseNoneFalse4163.20
3655934133391None26937.36.1 as per CSR-2018-19Providing wall bores in SSMEach312.23312.2315.0FalseNoneNoneFalseNoneFalse4683.450
3655935133391NoneNSRMaking Terrace bore or chajja bore (Old SR 2005-06)Nos93.6793.678.0FalseNoneNoneFalseNoneFalse749.360
3655936133391NoneCSR 2022 Vol-II, It. No.13.34Providing and Placeing and on terrace Polythene Water storage tanks 1500 Ltrs.Nos11.1511.153000.0FalseNoneNoneFalseNoneFalse33450.00
3655937133391None76 11.50.3 as per CSR-2018-19Providing & fixing Inspection Chamber 450x450 mm (interior clear dimensions)Nos6990.446990.446.0FalseNoneNoneFalseNoneFalse41942.640
3655938133391None76 11.50.2 as per CSR-2018-19Providing & fixing Inspection Chamber 600x600 mm (interior clear dimensions)Nos7778.447778.444.0FalseNoneNoneFalseNoneFalse31113.760
3655939133391None74 11.39 as per CSR-2018-19Constructing brick masonry circular type manhole 1.22 m internal dia at bottom 1.68 deep & 0.56 dia at topNos13091.2713091.272.0FalseNoneNoneFalseNoneFalse26182.540
3655940133391None9012.111 as per CSR-2018-19Providing and fixing 7.5 cms to 15 cms dia NP gratingEach154.88154.8814.0FalseNoneNoneFalseNoneFalse2168.320
3655941133391NoneCSR 2022 Vol-II, It. No.14.31 Pg No.128Providing & fixing 600 x 450 mm bevel led edge mirrorEach1511.581511.587.0FalseNoneNoneFalseNoneFalse10581.060
3655942133391None9413.50 as per CSR-2018-19Providing Nickle Plated (N.P) Metal Showers.Set875.97875.974.0FalseNoneNoneFalseNoneFalse3503.880
3655943133391NoneCSR 2022 Vol-II, It. No.14.7APg No.125Providing China clay Hand wash BasinUnit5105.925105.927.0FalseNoneNoneFalseNoneFalse35741.440
3655944133391NoneCSR 2022 Vol-II, It. No.14.40.2 Pg No.130Providing and fixing C.P. Brass Towel rail 600 mm length 20 mm diaEach614.54614.547.0FalseNoneNoneFalseNoneFalse4301.780
3655945133391NoneVI SI NO 45White marbles slab 60x150Sqm1361.851361.855.4FalseNoneNoneFalseNoneFalse7353.990
17224114770000NoneNoneBuildingsCONSTRUCTION OF 3 BAY FIRE STATION AT VASANTH NARSAPURA IN TUMKUR DIST SUMP652780.16
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3655946133392NoneCSR 2022 Vol-1, It. No.1.12 Pg No.8Earth work in surface excavation by mechanical means for lowering &leveling the ground for all works other than foundation in all kinds ofsoils & upto depth not exceeding 300mm as per drawing and technicalspecifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter includingdressing of excavated surfaces, disposing off or levelling the excavatedearth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum117.71117.7111.0FalseNoneNoneFalseNoneFalse1294.810
3655947133392NoneCSR 2022 Vol-1, It. No.1.14 Pg No.8Earth work in surface excavation by mechanical means for lowering &leveling the ground for all works other than foundation in all kinds ofsoils & upto depth not exceeding 300mm as per drawing and technicalspecifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter includingdressing of excavated surfaces, disposing off or levelling the excavatedearth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum126.38126.3852.6FalseNoneNoneFalseNoneFalse6647.5880
3655948133392NoneCSR 2022 Vol-1, It. No.2.1.2 Pg No.62Providing and laying in position plain cement concrete for levellingcourse for all works in foundation. The granite/trap/basalt crushedgraded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost ofall materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formworkshall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum7017.77017.75.46FalseNoneNoneFalseNoneFalse38316.6420
3655949133392NoneCSR 2022 Vol-I, It. No.2.2.2.1 Pg No.15For Footing M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately)Cum8671.028671.0216.18FalseNoneNoneFalseNoneFalse140297.10360
3655950133392NoneCSR 2022 Vol-I, It. No.2.2.2.1 Pg No.15For Footing M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately)Cum8671.028671.021.817FalseNoneNoneFalseNoneFalse15755.243340
3655951133392NoneCSR 2022 Vol-I, It. No.2.5.2 Pg No.17For Columns M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Providing and laying in position Reinforced cement concrete for allFoundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately)Cum13655.1413655.143.98FalseNoneNoneFalseNoneFalse54347.45720
3655952133392NoneCSR 2022 Vol-I, It. No.2.5.2Filling available excavated Earth (excluding rock) in sides of foundations upto plinth in layers not exceeding 20 cmCum329.57329.5772.19FalseNoneNoneFalseNoneFalse23791.65830
3655953133392NoneCSR 2022 Vol-II, It. No.8.1.1 Pg No.41Providing 15 mm cement plaster on the rough side of single or halfbrick wall of mix 1:4 (1 cement: 4 fine sand) including rounding offcorners wherever required smooth rendering, providing and removingscaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm365.51365.5127.31FalseNoneNoneFalseNoneFalse9982.07810
3655954133392NoneCSR 2022 Vol-II, It. No.8.3.1 Pg No.41External Plastering Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm438.61438.61175.511FalseNoneNoneFalseNoneFalse76980.879710
3655955133392NoneCSR 2022 Vol-II, It. No.8.10 Pg No.41For Celing Providing 6 mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) including rounding off corners wherever requiredsmooth rendering, providing and removing scaffolding, including costof materials, labour, curing complete as per specifications and as perdirections of Engineer-in-chargeSqm261.43261.4322.017FalseNoneNoneFalseNoneFalse5755.904310
3655956133392NoneCSR 2022 Vol-II, It. No.8.3.1 Pg No.41External Plastering Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm438.61438.6114.1FalseNoneNoneFalseNoneFalse6184.4010
3655957133392NoneCSR 2022 Vol-II, It. No.11.32 Pg No.84Providing Thermo-Mechanically Treated bars of grade Fe-500D ormore Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacentmembers whereever necessary complete as per Design including costof material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Tonne110837.22110837.222.02FalseNoneNoneFalseNoneFalse223891.18440
3655958133392NoneCSR 2022 Vol-V, It. No.13-SOR CODE H140A Pg No.111Providing & fixing 60x60 cms MS inspection DoorNos2651.462651.462.0FalseNoneNoneFalseNoneFalse5302.920
3655959133392NoneCSR 2022 Vol-V, It. No.Providing Anodized Aluminum ladder using 65 mmx 32mmRmtr6318.96318.97.0FalseNoneNoneFalseNoneFalse44232.30
17224114770000NoneNoneBuildingsCONSTRUCTION OF 3 BAY FIRE STATION AT VASANTH NARSAPURA IN TUMKUR DIST BOREWELL270205.64
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3655960133393NoneCSR 2022 Vol-V, It. No.O040A Pg No.151Geophysical investigation at site for sinking borewells for supplyingdrinking water to the habitation either through the Hand Pump MWS orP.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geologicalformation. Geophysical investigation of existing ground water in thevicinity, its quality, quantity and acceptability of the users, indicatingthe location of the site, recommended depth of casing pipe required toseal the top unconsolidated formation including an extra depth of 1.0metre in consolidated formation for proper seating of casing pipe, depthof drilling required to cover full depth of aquifer proposed to be tapped,probable yield and other information required including transportationof instruments and accessories to work site, engaging technical personaland labour required etc. NOTE: 1) Additional rate on item 1&2 isallowed for drilling in over burden and fixing Casing pipes beyond 20 M(for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%,b) Above 30 M - 30% (Measurement of overburden is restricted to thedepth of casing pipe fixed excluding initial depth of 20M and projectionabove ground level). 2) A sum of Rs. 100/- is to be deducted for DryBorewell towards yield test.Each6427.046427.041.0FalseNoneNoneFalseNoneFalse6427.040
3655961133393NoneCSR 2022 Vol-V, It. No.O020A Pg No.151Sinking borewell of 150mm dia. clear, using super fast hydraulic rig ofcapacity 250 PSIG & above 900 CMF and above, in all strata of earth,including over burden upto 20M, fixing of casing pipes, collars and capwith ncessary cutting, threading and welding including transportation ofrig and supporting vehicles, crew charges, cost of consumables, cost ofyield test at the final depth with a minimum working of compressor forone hour etc. complete. The cost excludes the cost of casing pipes,collars and caps etc.) for:Rmtr458.43458.4350.0FalseNoneNoneFalseNoneFalse22921.50
3655962133393NoneCSR 2022 Vol-V, It. No.O020B Pg No.151Above 50 -100mtsRmtr574.9574.950.0FalseNoneNoneFalseNoneFalse28745.00
3655963133393NoneCSR 2022 Vol-V, It. No.O020D Pg No.151Above 100 - 150 mtsRmtr610.83610.8350.0FalseNoneNoneFalseNoneFalse30541.50
3655964133393NoneCSR 2022 Vol-V, It. No.O020E Pg No.151Above 150 - 200 mtsRmtr708.71708.7150.0FalseNoneNoneFalseNoneFalse35435.50
3655965133393NoneCSR 2022 Vol-V, It. No.O020F Pg No.151Above 250 - 300mtsRmtr916.86916.8650.0FalseNoneNoneFalseNoneFalse45843.00
3655966133393NoneCSR 2022 Vol-II, It. No.336 Pg No.A22M.S. pipe 160 mm dia casing pipeRmtr1188.21188.248.0FalseNoneNoneFalseNoneFalse57033.60
3655967133393NoneCSR 2022 Vol-V, It. No.1818,D&R Pg No.54Providing and fixing MS casing collarsEach185.85185.858.0FalseNoneNoneFalseNoneFalse1486.80
3655968133393NoneCSR 2022 Vol-V, SL. No.1105,5888 Pg No.32MS casing capsEach203.2203.21.0FalseNoneNoneFalseNoneFalse203.20
3655969133393NoneCSR 2022 Vol-V, It. No.O020F Pg No.151Above200-250Rmtr831.37831.3750.0FalseNoneNoneFalseNoneFalse41568.50
17224114770000NoneNoneBuildingsCONSTRUCTION OF 3 BAY FIRE STATION AT VASANTH NARSAPURA IN TUMKUR DIST Soak and septic393707.28
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3655970133394NoneCSR 2022 Vol-1, It. No.1.14.1 Pg No.8Earth work excavation for foundation of structures upto 3 mtrs.by mechanical means as per drawing and technical specification,including setting out, providing shoring, strutting and bracing, removalof stumps and other deleterious matter, dressing of sides and bottom,filling back the excavated earth to the extent required and utilising /transporting the remaining earth upto 1.00km lead. including cost oflabour, materials and HOM etc., complete.Cum117.71117.7170.96FalseNoneNoneFalseNoneFalse8352.70160
3655971133394NoneCSR 2022 Vol-1, It. No.2.1.2 Pg No.15Providing & laying cement concrete of mix 1:4:8 with OPC cement @ 180kgsCum7017.77017.72.87FalseNoneNoneFalseNoneFalse20140.7990
3655972133394NoneCSR 2022 Vol-I, It. No.2.5.2 Pg No.17KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M25 with OPC cement @320 Kgs with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintels and beams retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcements as per specifications. Specification No. KBS 4.1, 4.6 for walls and Roof slab.Cum8478.338478.3314.05FalseNoneNoneFalseNoneFalse119120.53650
3655973133394NoneCSR 2022 Vol-I, It. No.2.4.1 Pg No.17Providing & laying cement concrete of mix 1:2:4 with cement @ 240kgs for CC 1:2:4 for Septick tankCum7193.287193.281.1FalseNoneNoneFalseNoneFalse7912.6080
3655974133394NoneCSR 2022 Vol-II, It. No.8.3.1 Pg No.41Providing 20mm thick cement plaster with cement mortar 1:4 for Septick tank in side Plaster with WPCSqm438.61438.6194.08FalseNoneNoneFalseNoneFalse41264.42880
3655975133394NoneCSR 2022 Vol-II, It. No.8.4.1 Pg No.41Providing 12mm thick cement plaster with cement mortar 1:4 for Septick tank in Ceiling Plaster with WPCSqm264.04264.0412.29FalseNoneNoneFalseNoneFalse3245.05160
3655976133394NoneCSR 2022 Vol-II, It. No.11.32 Pg No.84Providing T.M.T steel bars Fe 500 reinforcement for R.C.C workTonne110837.22110837.221.12FalseNoneNoneFalseNoneFalse124137.68640
3655977133394None25 5.1 as per CSR-2018-19KSRB 5-1.1: Providing and constructing granite trap basalt rubble stone masonery in foundation with mud mortar (uncoursed), bond stones at 2m. Apart in each course including cost of materials, labour, curing complete as per specification. KBS 5.1.12Cum8199.78199.78.48FalseNoneNoneFalseNoneFalse69533.4560
17224114770000NoneNoneBuildingsCONSTRUCTION OF 3 BAY FIRE STATION AT VASANTH NARSAPURA IN TUMKUR DIST Electrical2761722.95
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3655978133395None1.2.1Conceled Conduit System : Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thick Mtr77.8877.88350.0FalseNoneNoneFalseNoneFalse27258.00
3655979133395None1.2.2Conceled Conduit System : Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick Mtr92.0492.04350.0FalseNoneNoneFalseNoneFalse32214.00
3655980133395None1.3.1Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 19/20mm dia 2mm thick Mtr80.2480.24120.0FalseNoneNoneFalseNoneFalse9628.80
3655981133395None1.3.2Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25mm dia 2mm thick Mtr93.2293.22150.0FalseNoneNoneFalseNoneFalse13983.00
3655982133395None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 SqmmMtr30.6830.68650.0FalseNoneNoneFalseNoneFalse19942.00
3655983133395None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 Sqmm Mtr49.5649.561050.0FalseNoneNoneFalseNoneFalse52038.00
3655984133395None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 Sqmm Mtr74.3474.34350.0FalseNoneNoneFalseNoneFalse26019.00
3655985133395None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 Sqmm Mtr108.56108.56100.0FalseNoneNoneFalseNoneFalse10856.00
3655986133395None2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point up to 3Mtr from tapping point to out let via switch Point317.42317.425.0FalseNoneNoneFalseNoneFalse1587.10
3655987133395None2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Medium point above 3mtr up to 6Mtr from tapping point to out let via switch Point447.22447.2240.0FalseNoneNoneFalseNoneFalse17888.80
3655988133395None2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Above 6Mtr up to 10Mtr from tapping Point to out let via switch Point654.9654.950.0FalseNoneNoneFalseNoneFalse32745.00
3655989133395NoneEle 14-15 4.2Supplying and fixing PBBC bakelite straight or slant batten holder and wiring, within 60w/230 Volts lamps. Make Group "A" materials and as per the directions of Engineer in charge of the work. Each103.84103.8450.0FalseNoneNoneFalseNoneFalse5192.00
3655990133395None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3 way No187.62187.6225.0FalseNoneNoneFalseNoneFalse4690.50
3655991133395None3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 way No208.86208.8620.0FalseNoneNoneFalseNoneFalse4177.20
3655992133395None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 way No259.6259.620.0FalseNoneNoneFalseNoneFalse5192.00
3655993133395None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 way Each307.98307.986.0FalseNoneNoneFalseNoneFalse1847.880
3655994133395None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 way Each376.98376.9812.0FalseNoneNoneFalseNoneFalse4523.760
3655995133395None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. iv) 1-3 Module Each189.98189.9825.0FalseNoneNoneFalseNoneFalse4749.50
3655996133395None3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. iv) 4 Module Each206.5206.520.0FalseNoneNoneFalseNoneFalse4130.00
3655997133395None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. iv) 6 Module Each276.12276.1220.0FalseNoneNoneFalseNoneFalse5522.40
3655998133395None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. iv) 8 Module Each335.12335.126.0FalseNoneNoneFalseNoneFalse2010.720
3655999133395None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. v) 10 - 12 Module Each405.92405.9212.0FalseNoneNoneFalseNoneFalse4871.040
3656000133395None3.6.1Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Make - Group "A" materials and as per the directions of Engineer in charge of the work. i) 6 Amps one way Each120.36120.36130.0FalseNoneNoneFalseNoneFalse15646.80
3656001133395None3.6.7Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Make - Group "A" materials and as per the directions of Engineer in charge of the work. iv) b) 16 Amps one way switch Each212.4212.48.0FalseNoneNoneFalseNoneFalse1699.20
3656002133395None3.6.3Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Make - Group "A" materials and as per the directions of Engineer in charge of the work. ii) 6 Amps 3 way socket Each201.78201.7840.0FalseNoneNoneFalseNoneFalse8071.20
3656003133395None3.6.11Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. as per the directions of Engineer in charge of the work. ii) 16 Amp Universal socket Each278.48278.484.0FalseNoneNoneFalseNoneFalse1113.920
3656004133395None3.6.4Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. as per the directions of Engineer in charge of the work. ii) Stepped fan regulator two module Each421.26421.2612.0FalseNoneNoneFalseNoneFalse5055.120
3656005133395None3.6.13Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per the directions of Engineer in charge of the work. l) RJ45/I.O. outlet Each397.66397.6612.0FalseNoneNoneFalseNoneFalse4771.920
3656006133395NoneApproved rates Alur fire stationSupplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Make - Group "A" materials and as per the directions of Engineer in charge of the work. l) RJ 11 Each295.0295.02.0FalseNoneNoneFalseNoneFalse590.00
3656007133395None11.3.3Supplying of feet Aluminium Batten with integrated LED tube . with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance 28 WEach1497.421497.4225.0FalseNoneNoneFalseNoneFalse37435.50
3656008133395None11.3.2Supplying of feet Aluminium Batten with integrated LED tube with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance 20wEach814.2814.215.0FalseNoneNoneFalseNoneFalse12213.00
3656009133395None11.6.3Supplying of recess mounting non integral type 2'x2' 36W luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clamps,Each5372.545372.549.0FalseNoneNoneFalseNoneFalse48352.860
3656010133395None13.7.1Fixing all types and all capacities fluorescent/false ceiling/spot light/CFL fittings indoor on the wall/ceiling/rafters/girders using 23/0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps (if required).a) On wall/ceiling/Rafter/Girders Each143.96143.9649.0FalseNoneNoneFalseNoneFalse7054.040
3656011133395None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular model. Each3521.123521.1213.0FalseNoneNoneFalseNoneFalse45774.560
3656012133395None6.5.1Supplying wall mounting fan suitable to operate at single-phase 230 V A.C. supply, 300mm Sweep Each2940.562940.562.0FalseNoneNoneFalseNoneFalse5881.120
3656013133395None13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Each201.78201.7815.0FalseNoneNoneFalseNoneFalse3026.70
3656014133395None6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. Each1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
3656015133395None13.14Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. Each580.56580.564.0FalseNoneNoneFalseNoneFalse2322.240
3656016133395None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia Each4141.84141.84.0FalseNoneNoneFalseNoneFalse16567.20
3656017133395None12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts Each5022.085022.086.0FalseNoneNoneFalseNoneFalse30132.480
3656018133395None12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required GI strip 25X3mm Mtr96.7696.7650.0FalseNoneNoneFalseNoneFalse4838.00
3656019133395None12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper strip Mtr672.6672.610.0FalseNoneNoneFalseNoneFalse6726.00
3656020133395None12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate No8756.788756.786.0FalseNoneNoneFalseNoneFalse52540.680
3656021133395NoneEle SR 19-20 6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire Mtr22.4222.4250.0FalseNoneNoneFalseNoneFalse1121.00
3656022133395None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. Sqmm0.510.51110000.0FalseNoneNoneFalseNoneFalse56100.00
3656023133395None5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6mm Mtr359.9359.98.0FalseNoneNoneFalseNoneFalse2879.20
3656024133395None5.40.2Supplying . amps rated 3phase with neutral bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers. 250Amps 4x30x10mm Alluminium Strips Mtr4053.34053.31.5FalseNoneNoneFalseNoneFalse6079.950
3656025133395None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C 50Hz 12/24v D.C. Each607.7607.73.0FalseNoneNoneFalseNoneFalse1823.10
3656026133395None5.29Supplying, fixing and wiring 3 phase Digital Ammeter/ Voltmeter Each1681.91681.92.0FalseNoneNoneFalseNoneFalse3363.80
3656027133395None5.21Supplying, fixing and wiring Earth Leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DIN rail/flush mounting on panel board. Each10920.910920.91.0FalseNoneNoneFalseNoneFalse10920.90
3656028133395None5.20.8Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 32-40 Amps 4 pole Each6073.466073.462.0FalseNoneNoneFalseNoneFalse12146.920
3656029133395None5.14.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 160Amps 25kA Each15867.4615867.461.0FalseNoneNoneFalseNoneFalse15867.460
3656030133395None5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Circuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 100aMPS 25kA. Each10014.6610014.664.0FalseNoneNoneFalseNoneFalse40058.640
3656031133395None5.11.3Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution) 125 Amps Each12184.6812184.682.0FalseNoneNoneFalseNoneFalse24369.360
3656032133395None5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP Each489.7489.710.0FalseNoneNoneFalseNoneFalse4897.00
3656033133395None5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps DP Each872.02872.023.0FalseNoneNoneFalseNoneFalse2616.060
3656034133395None5.18.7Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 3) 5-32Amps TPN Each2026.062026.063.0FalseNoneNoneFalseNoneFalse6078.180
3656035133395None5.19.11Supplying and fixing regular MCB distribution boards on wall/wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure 1) Double Door 4 Way TP &N Each4764.844764.843.0FalseNoneNoneFalseNoneFalse14294.520
3656036133395NoneApproved rates Devanahalli fire stationSupplying and fixing Industrial bell Each9440.09440.01.0FalseNoneNoneFalseNoneFalse9440.00
3656037133395None11.8.3Supply of LED Streetlight 70 Watts luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000Each7070.567070.566.0FalseNoneNoneFalseNoneFalse42423.360
3656038133395None13.2.1Supplying and Fixing.mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Using 25mm dia G.I.pipe Each1419.541419.546.0FalseNoneNoneFalseNoneFalse8517.240
3656039133395None4.1.1Fabricating, supplying and erecting Swaged tubular Pole of height .m having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the Pole(as per IS) and 40 mm dia GI/flexible PVC pipe of 1m length fitted to the heavy gauge polycarbonate control box including 5 Way connector of size 167 x 125 x 82 mm for 7.5M Pole/ 200 x 160 x 98 mm for remaining length of Pole with front opening cover, with locking arrangements and suitable capacity MCB/DP switch, The Pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the Pole to the ground level and the coping CC shall be upto 0.6m above ground level as per IS2713-7 9m (5m Hb,165.1 mm dia 4.85 mm thick x 2m Hm, 139.7 mm dia 4.50 mm thick x 2m Ht,114.3 mm dia 3.65 mm thick) as per IS 410 SP 32 Each18290.018290.04.0FalseNoneNoneFalseNoneFalse73160.00
3656040133395None11.7.2Supply of LED pole mounting type post top lantern 25 Watts with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr@ Lumen MaintenanceEach9111.969111.963.0FalseNoneNoneFalseNoneFalse27335.880
3656041133395None13.6Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI/ GI or any other pipe using required size of reducer, wiring using suitable wires. No233.64233.643.0FalseNoneNoneFalseNoneFalse700.920
3656042133395None32.05Supplying of 1.1 KV LT UG cable 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) Mtr167.37167.37100.0FalseNoneNoneFalseNoneFalse16737.00
3656043133395None32.09Supplying of 1.1 KV LT UG cable 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-397535 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) Mtr181.79181.79150.0FalseNoneNoneFalseNoneFalse27268.50
3656044133395None32.03Supplying of 1.1 KV LT UG cable 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) Mtr139.24139.24200.0FalseNoneNoneFalseNoneFalse27848.00
3656045133395None21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm Mtr24.6424.64300.0FalseNoneNoneFalseNoneFalse7392.00
3656046133395None21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 Sqmm Mtr36.7336.73150.0FalseNoneNoneFalseNoneFalse5509.50
3656047133395NoneEle SR 19-20 6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) In soil (ordinary) Mtr89.6889.68250.0FalseNoneNoneFalseNoneFalse22420.00
3656048133395NoneEle SR 14-15 7.20.4Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II suitable for drawing under ground cables.63mm OD / 50mm ID Mtr307.98307.9860.0FalseNoneNoneFalseNoneFalse18478.80
3656049133395NoneEle SR 14-15 7.20.1Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II suitable for drawing under ground cables.40mm OD / 32mm ID Mtr115.64115.64200.0FalseNoneNoneFalseNoneFalse23128.00
3656050133395NoneEle SR 19-20 6.9.1Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.) 40mm Mtr395.3395.310.0FalseNoneNoneFalseNoneFalse3953.00
3656051133395None9.3.2Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 3 kVA ON LINE UPSMtr45688.4245688.422.0FalseNoneNoneFalseNoneFalse91376.840
3656052133395None9.5.5Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 60 /65 AH capacity h No7567.347567.3416.0FalseNoneNoneFalseNoneFalse121077.440
3656053133395None6.22Supplying fixing of Network Switches 16 Port 10/100 SwitchNo5672.265672.262.0FalseNoneNoneFalseNoneFalse11344.520
3656054133395None8.9.6Supplying fixing of Network Switches 16 Port 10/100 Switch Nos2891.02891.02.0FalseNoneNoneFalseNoneFalse5782.00
3656055133395None8.11.1Supplying & fixing of 2 mtrs. Cat 6Patch Cable. 2Mtr Each303.26303.2612.0FalseNoneNoneFalseNoneFalse3639.120
3656056133395None8.12.2Supplying & Fixing of Patch panel for Lan Cabling. 24 Port 10/100 Patch Panel Each4838.04838.02.0FalseNoneNoneFalseNoneFalse9676.00
3656057133395None8.1LAN networking: Supplying and drawing UTP-CAT 6E LAN cable. 3 kVA ON LINE UPS Each44.8444.84400.0FalseNoneNoneFalseNoneFalse17936.00
3656058133395None8.4.2Supplying fixing of Network Switches 16 Port 10/100 SwitchEach8232.868232.862.0FalseNoneNoneFalseNoneFalse16465.720
3656059133395None8.10.2Supplying & Fixing of I/O Socket with back box Double I/O Each649.0649.08.0FalseNoneNoneFalseNoneFalse5192.00
3656060133395NoneCivil SR 18-19 Pg-XLVII 4Pump sets : Supply, Installing fixing, testing and commissioning of Vertical/ Horizontal multistage 3 phase 5 HP Mono submersible pumpset, of adequate HP, capable of giving a required discharge at suitable head,to 'work on 3 Ph 50 Hz, 400/440V with necessary gate valve, NRV , unions,flanges in 1:2:4 etc., complete with wiring fromTPN switch to control panel and to the pumps etc. complete. Set26231.426231.41.0FalseNoneNoneFalseNoneFalse26231.40
3656061133395None5.1Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP Each2273.862273.862.0FalseNoneNoneFalseNoneFalse4547.720
3656062133395NoneApproved rates PG 2025Fixing charges of pumpset after aligning, leveling & assembling etc, inclusive of transportation charges to work spot. No1180.01180.02.0FalseNoneNoneFalseNoneFalse2360.00
3656063133395NoneApproved rates PG 2025Supplying of 50 mm kirloskar / other approved make CI screwed foot valve. Make- Using group "A" materials. And as per the directions of engineer incharge of the work. No531.0531.02.0FalseNoneNoneFalseNoneFalse1062.00
3656064133395None5.6.6Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 20"X20"x2.5" Each384.83384.832.0FalseNoneNoneFalseNoneFalse769.660
3656065133395NoneApproved ratesSupply of erection testing and commissioning of water level controller and connected accessoriersetcNo4720.04720.01.0FalseNoneNoneFalseNoneFalse4720.00
3656066133395NoneCivil SR 21-22 P150G Providing,supplying to work site, 7.50 HP 15 STG Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work Set51934.1651934.161.0FalseNoneNoneFalseNoneFalse51934.160
3656067133395NoneCivil SR-2021-22 P250ASupply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendment 50 mm dia nominal Each1475.01475.01.0FalseNoneNoneFalseNoneFalse1475.00
3656068133395NoneCivil SR-2021-22 P260ASupply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendment size 50 mm Each1504.51504.51.0FalseNoneNoneFalseNoneFalse1504.50
3656069133395NoneCivil SR-2021-22 P280BSupply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter for outdoor 6 to 15 HP pumps Set19470.019470.01.0FalseNoneNoneFalseNoneFalse19470.00
3656070133395NoneKUWSS&DB. (page 1).Erection of panel and Meter Borad : Erection of combined panel borad and meter borad unit with necessary materials and labour charges Inculuding providing cement concrete foundation bed ect complete. Set435.42435.421.0FalseNoneNoneFalseNoneFalse435.420
3656071133395NoneKUWSS&DB.Erection, Electrification and commissioning Work of Pump Sets : eraction of pumpset including aligning and balancing with all necessary erection materials and labour including supply and erection of two pair of supporting clamps, bore-well, cap, cable protector bolts, nuts, valve and gauges ect., Set1744.041744.041.0FalseNoneNoneFalseNoneFalse1744.040
3656072133395None2.6.3Supplying and Drawing 3 core flat PVC sheathed sumersible grade copper with flxible copper conductor confirming to rable 3 class 5 of IS: 8130-198 and virgin grade PVC insulation and sheethed suitable for working voltage upto 1100Volts. 4Sqmm of 56 strands 0.3mm dia. Make - Group ""A"" materials and as per the directions of Engineer in charge of the work. Rmtr198.24198.24600.0FalseNoneNoneFalseNoneFalse118944.00
3656073133395NoneCivil SR-2018-19 Pg-92 13.15 KSRB13-3.1: Providing and fixing in trenches galvanised / mild steel tubes (medium grade) nominal bore with all fittings (earth work in trenches to be measured and paid for separately) including cost of all materials, labour charges, HOM and testing complete as per specifications. Specification No.KBS 50 mm dia Mtr457.84457.84300.0FalseNoneNoneFalseNoneFalse137352.00
3656074133395NoneBescom sr 21-22 CDS-60Supplying & erection of Star rated 63 KVA transformer center 11kV/433V, 9 mtr RCC DP Transformer Structure with 9 mtr long RCC pole complete set materials like angle iron, bedding channels, belting cross arms bracess, round clamps etc.,(as per BESCOM SR 2021-22) and wiring with suitable capacity LT Lead wires, earthing 3 nos, forming transformer structure including transformer and labour charges and maintanence of one year or as per current KPTCL norms.Obtaining Govt.electrical inspectorate approval, charging and handing over to BESCOM in full manner. Make - ESCOM approved makesSet310437.94310437.941.0FalseNoneNoneFalseNoneFalse310437.940
3656075133395NoneBescom SR 21-22 4.06Construction of platform with size stone, cement concert for erection of 500 kVA Transformer/Metering cubicle/Heavy Equipment.Construction of platform (1.5x1.5x1.2) Mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour. Excavation of (1.5x1.5x1) Mtr pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10 cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9 Mtr below ground level and 1.2 Mtr above ground level neatly hammer dressed in cement morter 1:6. Providing and Laying cement concrete slab 1.5x1.5x0.10 Mtr withcement concrete of 1:2:4 mix forming & cutting complete, providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completelyEach35825.9835825.981.0FalseNoneNoneFalseNoneFalse35825.980
3656076133395NoneBescom SR 21-22 CDS- 57Providing Doble pole Structure at Tapping poin using PSCC poleJob69553.9269553.921.0FalseNoneNoneFalseNoneFalse69553.920
3656077133395NoneBescom SR 21-22 67.20Supplying & Fixing of Caution/Danger Board No172.28172.283.0FalseNoneNoneFalseNoneFalse516.840
3656078133395NoneCivil SR-18-19 37.2Supplying and fixing M.S. Rectangular poles made out of 2 equal angles of 65x65x6 mm welded together and fixed in CC (1:2:4) WITH 2 NOS 16mm dia M.S. hold fast rods each of length 25 cms. Including cost of all materials cutting, bending scaffolding wherever necessary, nicely finishing the welded joints with all lead lifts and as per the directions of the Engineer-in - charge of the work and including providing 2 coats of approved quality paint over one coat of shop painting ( excluding cost of earthwork and concrete) including cost of materials, labour, HOM complete as per specifications Mtr1013.621013.6230.0FalseNoneNoneFalseNoneFalse30408.60
3656079133395NoneBescom SR 21-22 38Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint Sqm1164.661164.6640.0FalseNoneNoneFalseNoneFalse46586.40
3656080133395NoneCivil SR Providing and spreading jelly-40mm size for transformer yard-(15'x20'-150mm) etc complete as per directions of engineer in charge of the work Cum1180.01180.03.0FalseNoneNoneFalseNoneFalse3540.00
3656081133395None5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron… and M S flat ……. With bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint, 40x40x6mm as per the directions of the engineer in charge of the work. Mtr359.68359.6842.0FalseNoneNoneFalseNoneFalse15106.560
3656082133395None1.01RCC Pole - 9 Mtr Long, 145 Kg WL (Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785 No8349.688349.682.0FalseNoneNoneFalseNoneFalse16699.360
3656083133395None7.02ACSR Conductor as per IS-398 (Part - 2/1996) Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM Km54556.1254556.120.5FalseNoneNoneFalseNoneFalse27278.060
3656084133395None2.02Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depthNo1313.341313.342.0FalseNoneNoneFalseNoneFalse2626.680
3656085133395None6.02Stringing of conductor Squirrel, Weasel, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps do - for Rabbit ACSR Km5145.985145.980.5FalseNoneNoneFalseNoneFalse2572.990
3656086133395NoneBescom SR 21-22 2.02Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth No863.0863.05.0FalseNoneNoneFalseNoneFalse4315.00
3656087133395NoneBescom SR 21-22 5.17Stringing of conductor Squirrel, Weasel, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps do - for Rabbit ACSR Km3299.03299.00.6FalseNoneNoneFalseNoneFalse1979.40
3656088133395NoneBescom SR 21-22 2.05Supplying & fixing LT 4 Pin Cross Arm - MS (Dwg No. BESCOM/GM/QS&S/32 Dtd 24.11.2018) No303.0303.02.0FalseNoneNoneFalseNoneFalse606.00
3656089133395NoneBescom SR 21-22 2.01Supplying & fixing 11 kV, Horizontal Cross Arm - Mild Steel (MS) (Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018) No390.0390.04.0FalseNoneNoneFalseNoneFalse1560.00
3656090133395NoneBescom SR 21-22 5.10Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT) Set201.0201.02.0FalseNoneNoneFalseNoneFalse402.00
3656091133395None6.02Stringing of conductor Squirrel, Weasel, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps do - for Rabbit ACSRKm5145.985145.980.5FalseNoneNoneFalseNoneFalse2572.990
3656092133395None2.01Supplying & fixing 11 kV, Horizontal Cross Arm - Mild Steel (MS) (Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018)No438.96438.962.0FalseNoneNoneFalseNoneFalse877.920
3656093133395None5.10Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)Set313.88313.882.0FalseNoneNoneFalseNoneFalse627.760
3656094133395None36.0711 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 - 400 Sqmm, (51 GI Wires - 4 mm Dia)Mtr2945.822945.8230.0FalseNoneNoneFalseNoneFalse88374.60
3656095133395None45.0311 kV, Jointing & Cable Termination Kit as per IS-1357 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable 3X400 SqmmEach15218.4615218.462.0FalseNoneNoneFalseNoneFalse30436.920
3656096133395None45.09Heat Shrinkable Outdoor Type Cable TerminationEach6322.446322.442.0FalseNoneNoneFalseNoneFalse12644.880
3656097133395NoneNSR 1Shiftng Charges11KVLINELS236000.0236000.01.0FalseNoneNoneFalseNoneFalse236000.00
3656098133395NoneApproved ratesSupplying and insstaling water purifire filter 25 LtrEach29500.029500.01.0FalseNoneNoneFalseNoneFalse29500.00
3656099133395NoneCIVIL SRPump sets Supply, Installing fixing, testing and ommissioning of Vertical/ Horizontal multistage 3 phase 1 HP Monosubmersiblepumpset, of adequate HP, capable of giving a required discharge atsuitablehead,to work on 3 Ph 50 Hz, 400/440V with necessary gate valveSet10782.8410782.841.0FalseNoneNoneFalseNoneFalse10782.840
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17224114800000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17224114800001NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of KarnatakaNone
17224114800001NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of karnataka public procurement portal due to internet connectivity issues and technical glitches at bidder s end.None
17224114800000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17224114800000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17224123230000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contract value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17224123310000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17224123470000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if anyNone
17224123550000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the rates.None
17224123620000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose onlyNone
17224123700000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KSPH & IDCL have the right to deduct the work bills and remit the same to respective PF offices.None
17224123820000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to time and if any variation occurs it shall be paid / refunded by / to the Corporation against documentary evidenceNone
17224123880000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund ActNone
17224123980000NoneNoneELIGIBILITYRemittance towards PF shall be commensurate with the labour component of the work involved.None
17224124040000NoneNoneELIGIBILITYThe Bidder shall remit PF of labourers to Bidders permanent PF code number onlyNone
17224124130000NoneNoneELIGIBILITYThe bidder should maintain register of labourers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17224124250000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17224124360000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the karnataka public procurement portal and www.ksphc.org web sites only.None
17224124450000NoneNoneELIGIBILITYBounded scanned hard copies are to be submitted duly marking the Page Nos. within 3 days after the last date of submission of the bid documents online to EE(Contracts), KSPH & IDCL, Bangalore.None
17224124540000NoneNoneELIGIBILITYThe rates quoted by the Contractor shall be deemed to be inclusive of all applicable taxes, GST, levies, duties and cess, Building Workers Welfare Cess etc., as applicable as per the latest Notifications of GoK and GoI prevailing as on the date of NIT. The Employer will perform such duties in regard to the deduction of such taxes at source as per applicable law. The Contractor should submit the tax invoice along with RA Bills.None
17224124740000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer(Contracts), KSPH & IDCL, Richmond Road, Bangalore 560025. Ph: 080-25584102 Extn - 130 / 114 / 117None
17224124820000NoneNoneELIGIBILITYThe bidder should furnish the documents relating to registration of GSTNone
17224124900000NoneNoneELIGIBILITYThe bidder should furnish the valid address, phone number & e mail IDNone
17224124990000NoneNoneELIGIBILITYThe intended bidder shall visit the site & quote his offer accordingly and for having visited the site, they should upload the photos while submitting the tender.None
17224125820000NoneNoneELIGIBILITYTenders must be accompanied by Earnest Money Deposit (EMD) of Rs. 4.03 Lakhs (Rupees Four Lakhs Three Thousand only), which may be paid fully through Karnataka Public Procurement Portal or Out of total EMD amount Rs. 1.00 lakh (Rupees One Lakh only) shall be paid online through Karnataka Public Procurement Portal using any of the following Payment Modes: Credit Card, Direct Debit, National Electronic Fund Transfer (NEFT), Over the Counter (OTC) and the balance amount of Rs. 3.03 Lakhs (Rupees Three Lakhs Three Thousand only) in the form of Bank Guarantee (BG) only issued from Nationalized/Scheduled Commercial Banks in the Name of MD, KSPH&IDCL, Bengaluru. The scan copy of the Bank Guarantee (BG) to be uploaded at the time of submission of bid documents and the original Bank Guarantee should be submitted to Office of the Executive Engineer (Contracts), KSPH & IDCL, No.59, Gen. K.S. Thimmayya Road, Bangalore 560025 On or before the Last date of receipt of tender and the non-compliance of the same leads to the rejection of the bid.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNone1.3 of Section-3 Qualification Information: Work performed as Prime Contractor (in the same name) on works of similar nature over during the five years (2019-20 to 2023-24)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The scanned original work experience certificate issued by not below the rank of Executive Engineer
NoneNoneNoneNone1.4 of Section-3 : Quantities of work executed as prime contractor (in the same name) during the last five years (2019-20 to 2023-24)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The scanned original work experience certificate issued by not below the rank of Executive Engineer
NoneNoneNoneNone1.5 of Section-3 Qualification Information : Information on works for which Tenders have been submitted and works which are yet to be completed as on the date of this Tender : (A) Existing commitments and ongoing works & (B) Works for which Tenders already submittedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The scanned original work experience certificate issued by not below the rank of Executive Engineer
NoneNoneNoneNone1.7 of Section-3: Qualification Information: Reports on the financial standing of the tenderer, such as profit and Loss statements and auditors reports for the last five years. (2019-20 to 2023-24)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Profit & Loss Statement from Registered Chartered Accountant
NoneNoneNoneNone3.2- To qualify for award of this contract, each Tender in his/her/their name should have in the last five years i.e. 2019-20 to 2023-24): (b) Satisfactorily completed as prime contractor (at least 90% of the contract value), at least one similar nature of work of value not less than Rs.134.30 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work Done certificate issued not below the rank of an Executive Engineer or equivalent.
NoneNoneNoneNoneITT - 3.2 d) The Tenderer or his identified sub-contractor should possess required valid electrical license for executing building electrification works and should have executed similar electrical works totalling Rs.11.50 Lakhs in any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Workdone certificate issued not below the rank of an Executive Engineer. In case of Sub Contractor licence & Consent letter also to be uploaded.
NoneNoneNoneNone3.2 (e) The Tenderer or his identified subcontractor should possess valid license for executing water supply/sanitary engineering works and should have executed similar water supply/sanitary engineering works totaling Rs.2.82 Lakhs in any one yearPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Workdone certificate issued not below the rank of an Executive Engineer. In case of Sub Contractor licence & Consent letter also to be uploaded.
NoneNoneNoneNoneBe a Class-II & above Civil registered contractor of State PWDs / Central/MES/ Govt. UndertakingsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Valid Registration Certificate issued by respective Depts
NoneNoneNoneNoneBe Registered with KSPH & IDCLCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Valid Registration Certificate issued by KSPHCL
NoneNoneNoneNoneIncome Tax returns & PANCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Income Tax returns and PAN certificates
NoneNoneNoneNoneBe Registered with GSTCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Valid Registration Certificate issued by Competent Authority
NoneNoneNoneNoneBe Registered with EPF AuthoritiesCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- EPF Registration Certificate
NoneNoneNoneNoneITT 3.2 - To qualify for award of this contract, each Tenderer / company in his / its name should have in the last five years i.e. 2019-20 to 2023-24 (c) Executed in any one year the minimum quantities of work executed (Please refer Tender Document)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued from not below the rank of an Executive Engineer or equivalent.
NoneNoneNoneNoneITT 3.3 (c)- Each Tenderer should further demonstrate Liquid assets and /or availability of credit facilities of no less than Rs.73.50 Lakhs (Credit lines/ letter of credit/ certificates from Nationalized / Scheduled banks for meeting the fund requirement etc (Unconditional)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Letter of Credit Certificates from Nationalized / Scheduled banks for meeting the fund requirement
NoneNoneNoneNoneITT 3.2 - To qualify for award of this contract, each Tenderer in his/her/their name should have in the last five years i.e. 2019-20 to 2023-24: (a) Achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs.537.15 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach Certificate from Registered Chartered Accountant with UDIN Number
NoneNoneNoneNone1.8 of Section-3 Qualification Information: Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are Proposed to be deployed on this contract, if awarded.OthersOthers
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Organization Chart & Company Profile
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
KSPH & IDCL Registration CertificateTrueTechnical Bid
Class-II & above Civil registered contractor of State PWDs / Central/MES/Govt. UndertakingsTrueTechnical Bid
Income Tax returns & PANTrueTechnical Bid
EPF Registration CertificateTrueTechnical Bid
Work Done Certificate - ITT 3.2 b Similar nature Work done certificateTrueTechnical Bid
Liquid assets and availability of credit facilitiesTrueTechnical Bid
Turnover Certificate - ITT 3.2 aTrueTechnical Bid
1.3.of Section-3 Qualification InformationTrueTechnical Bid
1.4.of Section-3 Qualification InformationTrueTechnical Bid
1.7.of Section-3 Qualification InformationTrueTechnical Bid
GST Registration CertificateTrueTechnical Bid
Executed minimum quantities of work - ITT 3.2 cTrueTechnical Bid
Work Done Certificate - ITT 3.2 d Electrical Work done certificateTrueTechnical Bid
Work Done Certificate - ITT 3.2 e Water supply /sanitary Work done certificateTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1722504284000
version0
createdDateNone
modifiedDateNone
blockNumberNo. 59, Richmond Road (Gen. K.S.Thimmaiah Road)
streetNone
cityBengaluru
stateKarnataka
pin560025
tenderRecallDTONone