1722423245000 | 1 | None | None | Buildings | CONSTRUCTION OF 3 BAY FIRE STATION AT YARAGATTI IN BELAGAVI DISTRICT UNDER K-SAFE-2 WORK | 26128193.76 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3659433 | 133529 | None | 1 12 P 8 Vol 1 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,usage of machinery & other appurtenances required to complete the work.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Cum | 117.71 | 117.71 | 525.0 | False | None | None | False | None | False | 61797.75 | 0 | 3659434 | 133529 | None | 1 14 1 P 8 Vol 1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. In all kinds of soils Depth upto 3 m | Cum | 126.38 | 126.38 | 464.72 | False | None | None | False | None | False | 58731.3136 | 0 | 3659435 | 133529 | None | 1 15 1 P 8 Vol 1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 449.76 | 449.76 | 316.82 | False | None | None | False | None | False | 142492.9632 | 0 | 3659436 | 133529 | None | 2 1 2 P 15 Vol 1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.,Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Foundation & floor bed | Cum | 7017.7 | 7017.7 | 145.57 | False | None | None | False | None | False | 1021566.589 | 0 | 3659437 | 133529 | None | 2 2 3 P 15 Vol 1 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (including cost of providing & removing formwork as per Design & Drawing) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Column footing | Cum | 8478.33 | 8478.33 | 56.97 | False | None | None | False | None | False | 483010.4601 | 0 | 3659438 | 133529 | None | 5 3 P 9 Vol 2 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) as per specifications., ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Cum | 7688.0 | 7688.0 | 41.53 | False | None | None | False | None | False | 319282.64 | 0 | 3659439 | 133529 | None | 5 4 P 9 Vol 2 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) as per specifications.,,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Cum | 7915.97 | 7915.97 | 42.48 | False | None | None | False | None | False | 336270.4056 | 0 | 3659440 | 133529 | None | 2 5 2 P 16 Vol 1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (including cost of providing & removing formwork as per Design & Drawing) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Column- Ground Floor | Cum | 14413.41 | 14413.41 | 27.8 | False | None | None | False | None | False | 400692.798 | 0 | 3659441 | 133529 | None | 2 5 2 P 16 Vol 1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (including cost of providing & removing formwork as per Design & Drawing) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Column- First Floor | Cum | 14498.2 | 14498.2 | 20.13 | False | None | None | False | None | False | 291848.766 | 0 | 3659442 | 133529 | None | 2 4 3 P 17 Vol 1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications..,(including cost of providing & removing formwork as per Design & Drawing) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Grade & Plinth beam. | Cum | 11775.46 | 11775.46 | 29.54 | False | None | None | False | None | False | 347847.0884 | 0 | 3659443 | 133529 | None | 1 9 P 7 Vol 1 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, with all lead and lift,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Cum | 329.57 | 329.57 | 240.16 | False | None | None | False | None | False | 79149.5312 | 0 | 3659444 | 133529 | None | 1 8 Vol-1 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Cum | 587.29 | 587.29 | 587.6 | False | None | None | False | None | False | 345091.604 | 0 | 3659445 | 133529 | None | 6 8 Vol 2 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor | Cum | 9873.59 | 9873.59 | 110.72 | False | None | None | False | None | False | 1093203.8848 | 0 | 3659446 | 133529 | None | 6 8 Vol 2 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor | Cum | 9972.33 | 9972.33 | 63.11 | False | None | None | False | None | False | 629353.7463 | 0 | 3659447 | 133529 | None | 6 8 Vol 2 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Terrace Floor | Cum | 10071.06 | 10071.06 | 23.95 | False | None | None | False | None | False | 241201.887 | 0 | 3659448 | 133529 | None | 6 15 Vol 2 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor | Sqm | 1279.89 | 1279.89 | 24.64 | False | None | None | False | None | False | 31536.4896 | 0 | 3659449 | 133529 | None | 6 15 Vol 2 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor | Sqm | 1292.69 | 1292.69 | 27.3 | False | None | None | False | None | False | 35290.437 | 0 | 3659450 | 133529 | None | 2 1 4 P 15 Vol 1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.,(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates For coping & window cills. Ground Floor | Cum | 8088.01 | 8088.01 | 11.13 | False | None | None | False | None | False | 90019.5513 | 0 | 3659451 | 133529 | None | 2 1 4 P 15 Vol 1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.,(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates For coping & window cills. First Floor | Cum | 8165.03 | 8165.03 | 1.88 | False | None | None | False | None | False | 15350.2564 | 0 | 3659452 | 133529 | None | 2 14 P 15 Vol 1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.,(including cost of providing & removing formwork as per Design & Drawing),including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates For coping & window cills. Terrace Floor | Cum | 8242.06 | 8242.06 | 1.14 | False | None | None | False | None | False | 9395.9484 | 0 | 3659453 | 133529 | None | 2 5 2 P 16 Vol 1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(including cost of providing & removing formwork as per Design & Drawing) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Staircase/Roofslab/Wall Shelves-Ground Floor | Cum | 12717.72 | 12717.72 | 40.45 | False | None | None | False | None | False | 514431.774 | 0 | 3659454 | 133529 | None | 2 5 2 P 16 Vol 1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(including cost of providing & removing formwork as per Design & Drawing) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Lintel/Roofbeam-Ground Floor | Cum | 13565.56 | 13565.56 | 21.95 | False | None | None | False | None | False | 297764.042 | 0 | 3659455 | 133529 | None | 2 5 2 P 16 Vol 1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(including cost of providing & removing formwork as per Design & Drawing) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Staircase/Roofslab/Wall Shelves-First Floor | Cum | 12802.5 | 12802.5 | 76.5 | False | None | None | False | None | False | 979391.25 | 0 | 3659456 | 133529 | None | 2 5 2 P 16 Vol 1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(including cost of providing & removing formwork as per Design & Drawing) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Lintel/Roofbeam-First Floor | Cum | 13650.35 | 13650.35 | 22.96 | False | None | None | False | None | False | 313412.036 | 0 | 3659457 | 133529 | None | 2 5 2 P 16 Vol 1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(including cost of providing & removing formwork as per Design & Drawing) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Plain Chejja-Ground Floor | Cum | 12293.79 | 12293.79 | 0.75 | False | None | None | False | None | False | 9220.3425 | 0 | 3659458 | 133529 | None | 2 5 2 P 16 Vol 1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(including cost of providing & removing formwork as per Design & Drawing) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates, ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Plain Chejja-First Floor | Cum | 12378.58 | 12378.58 | 0.7 | False | None | None | False | None | False | 8665.006 | 0 | 3659459 | 133529 | None | 2 1 6 15 Vol 1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates For Screed concrete with WPC over roof slab. Ground Floor | Cum | 7735.08 | 7735.08 | 12.37 | False | None | None | False | None | False | 95682.9396 | 0 | 3659460 | 133529 | None | 2 1 6 15 Vol 1 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates For Screed concrete with WPC over roof slab. First Floor | Cum | 7812.43 | 7812.43 | 15.5 | False | None | None | False | None | False | 121092.665 | 0 | 3659461 | 133529 | None | 2 11 a 18 Vol 1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.-Ground Floor | t | 110837.22 | 110837.22 | 26.08 | False | None | None | False | None | False | 2890634.6976 | 0 | 3659462 | 133529 | None | 2 11 a 18 Vol 1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.-First Floor | t | 111945.6 | 111945.6 | 13.64 | False | None | None | False | None | False | 1526937.984 | 0 | 3659463 | 133529 | None | 8 19 1 44 Vol 2 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining,including cost of materials, labour, curing as per specifications.,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work | Sqm | 315.95 | 315.95 | 66.8 | False | None | None | False | None | False | 21105.46 | 0 | 3659464 | 133529 | None | 8 9 P 42 Vol 2 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Outside walls-Ground Floor | Sqm | 477.02 | 477.02 | 448.44 | False | None | None | False | None | False | 213914.8488 | 0 | 3659465 | 133529 | None | 8 9 P 42 Vol 2 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications,,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Outside walls-First Floor | Sqm | 481.79 | 481.79 | 311.87 | False | None | None | False | None | False | 150255.8473 | 0 | 3659466 | 133529 | None | 8 9 P 42 Vol 2 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications,,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Outside walls-Terrace Floor | Sqm | 486.56 | 486.56 | 101.3 | False | None | None | False | None | False | 49288.528 | 0 | 3659467 | 133529 | None | 8 10 P 43 Vol 2 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Ceiling Ground Floor | Sqm | 261.43 | 261.43 | 415.68 | False | None | None | False | None | False | 108671.2224 | 0 | 3659468 | 133529 | None | 8 10 P 43 Vol 2 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Ceiling First Floor | Sqm | 264.04 | 264.04 | 229.71 | False | None | None | False | None | False | 60652.6284 | 0 | 3659469 | 133529 | None | 8 10 P 43 Vol 2 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Ceiling Terrace Floor | Sqm | 266.66 | 266.66 | 23.72 | False | None | None | False | None | False | 6325.1752 | 0 | 3659470 | 133529 | None | 8 1 2 P 41 Vol 2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour, curing complete as per specifications, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Inside walls-Ground Floor | Sqm | 298.6 | 298.6 | 554.66 | False | None | None | False | None | False | 165621.476 | 0 | 3659471 | 133529 | None | 8 1 2 P 41 Vol 2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour, curing complete as per specifications, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Inside walls-First Floor | Sqm | 301.59 | 301.59 | 369.6 | False | None | None | False | None | False | 111467.664 | 0 | 3659472 | 133529 | None | 8 1 2 P 41 Vol 2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour, curing complete as per specifications, including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Inside walls- Terrace Floor | Sqm | 304.57 | 304.57 | 56.58 | False | None | None | False | None | False | 17232.5706 | 0 | 3659473 | 133529 | None | 8 51 P 50 Vol 2 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications, including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor | Sqm | 123.9 | 123.9 | 1017.41 | False | None | None | False | None | False | 126057.099 | 0 | 3659474 | 133529 | None | 8 51 50 Vol 2 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications, including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor | Sqm | 123.9 | 123.9 | 686.14 | False | None | None | False | None | False | 85012.746 | 0 | 3659475 | 133529 | None | 8 51 50 Vol 2 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications, including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Terrace Floor | Sqm | 123.9 | 123.9 | 80.3 | False | None | None | False | None | False | 9949.17 | 0 | 3659476 | 133529 | None | 8 2 2 P 41 Vol 2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Dado portion Ground Floor | Sqm | 345.68 | 345.68 | 52.71 | False | None | None | False | None | False | 18220.7928 | 0 | 3659477 | 133529 | None | 8 2 2 P 41 Vol 2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Dado portion First Floor | Sqm | 349.14 | 349.14 | 61.74 | False | None | None | False | None | False | 21555.9036 | 0 | 3659478 | 133529 | None | 8 16 a 44 Vol 2 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges,curing, complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per directions of the Engineer in-charge of the work.-Ground Floor | Sqm | 1533.88 | 1533.88 | 16.92 | False | None | None | False | None | False | 25953.2496 | 0 | 3659479 | 133529 | None | 8 16 a 44 Vol 2 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges,curing, complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per directions of the Engineer in-charge of the work.-First Floor | Sqm | 1533.88 | 1533.88 | 43.22 | False | None | None | False | None | False | 66294.2936 | 0 | 3659480 | 133529 | None | 9 24 Vol 2 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent., including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor | Sqm | 3500.17 | 3500.17 | 174.72 | False | None | None | False | None | False | 611549.7024 | 0 | 3659481 | 133529 | None | 9 24 Vol 2 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent., including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor | Sqm | 3568.96 | 3568.96 | 47.39 | False | None | None | False | None | False | 169133.0144 | 0 | 3659482 | 133529 | None | 9 34 Vol 2 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor | Sqm | 1914.25 | 1914.25 | 25.21 | False | None | None | False | None | False | 48258.2425 | 0 | 3659483 | 133529 | None | 9 34 Vol 2 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.,., including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor | Sqm | 1933.4 | 1933.4 | 20.71 | False | None | None | False | None | False | 40040.714 | 0 | 3659484 | 133529 | None | 9 17 2 Vol 2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Size of Tile 600x600 mm Ground Floor | Sqm | 1455.82 | 1455.82 | 102.57 | False | None | None | False | None | False | 149323.4574 | 0 | 3659485 | 133529 | None | 9 17 2 Vol 2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade,over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Size of Tile 600x600 mm First Floor | Sqm | 1470.38 | 1470.38 | 109.31 | False | None | None | False | None | False | 160727.2378 | 0 | 3659486 | 133529 | None | 9 11 Vol 2 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor | Sqm | 1101.47 | 1101.47 | 27.63 | False | None | None | False | None | False | 30433.6161 | 0 | 3659487 | 133529 | None | 9 11 Vol 2 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor | Sqm | 1112.49 | 1112.49 | 22.21 | False | None | None | False | None | False | 24708.4029 | 0 | 3659488 | 133529 | None | 9 39 Vol 2 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor | Sqm | 1795.31 | 1795.31 | 52.71 | False | None | None | False | None | False | 94630.7901 | 0 | 3659489 | 133529 | None | 9 39 Vol 2 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor | Sqm | 1813.26 | 1813.26 | 61.74 | False | None | None | False | None | False | 111950.6724 | 0 | 3659490 | 133529 | None | 1 23 11 Vol 1 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering,including cost of all materials and labour with all lead and lift complete as per specifications.,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Cum | 3323.0 | 3323.0 | 54.71 | False | None | None | False | None | False | 181801.33 | 0 | 3659491 | 133529 | None | 9 2 Vol 2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Sqm | 991.2 | 991.2 | 221.61 | False | None | None | False | None | False | 219659.832 | 0 | 3659492 | 133529 | None | 12 13 1 P100 Vol 2 | Providing Sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor | Cum | 122431.78 | 122431.78 | 0.32 | False | None | None | False | None | False | 39178.1696 | 0 | 3659493 | 133529 | None | 12 13 1 P100 Vol 2 | Providing Sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor | Cum | 122431.78 | 122431.78 | 0.27 | False | None | None | False | None | False | 33056.5806 | 0 | 3659494 | 133529 | None | 12 51 Vol 2 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead, including cost of materials, labour charges, complete as per specifications..,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor | Nos | 1258.82 | 1258.82 | 7.0 | False | None | None | False | None | False | 8811.74 | 0 | 3659495 | 133529 | None | 12 51 Vol 2 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead, including cost of materials, labour charges, complete as per specifications..,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor | Nos | 1258.82 | 1258.82 | 6.0 | False | None | None | False | None | False | 7552.92 | 0 | 3659496 | 133529 | None | 12 57 4 Vol 2 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.- 35 mm thick both side Teak Ground Floor | Sqm | 5615.15 | 5615.15 | 4.92 | False | None | None | False | None | False | 27626.538 | 0 | 3659497 | 133529 | None | 12 57 4 Vol 2 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.- 35 mm thick both side Teak First Floor | Sqm | 5671.3 | 5671.3 | 6.56 | False | None | None | False | None | False | 37203.728 | 0 | 3659498 | 133529 | None | 12 57 1 P 105 Vol 2 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.- 30 mm thick both side Teak Ground Floor | Sqm | 5009.28 | 5009.28 | 9.02 | False | None | None | False | None | False | 45183.7056 | 0 | 3659499 | 133529 | None | 12 57 1 P 105 Vol 2 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.- 30 mm thick both side Teak First Floor | Sqm | 5059.37 | 5059.37 | 4.41 | False | None | None | False | None | False | 22311.8217 | 0 | 3659500 | 133529 | None | 12 96 P 112 Vol 2 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame complete as per spcification.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor | m | 796.68 | 796.68 | 20.4 | False | None | None | False | None | False | 16252.272 | 0 | 3659501 | 133529 | None | 12 96 P 112 Vol 2 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame complete as per spcification.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor | m | 796.68 | 796.68 | 20.4 | False | None | None | False | None | False | 16252.272 | 0 | 3659502 | 133529 | None | 12 97 1 P 112 Vol 2 | Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin,moulded to 3 mm thick FRP laminate for forming hollow rails and styles,with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames as per specifications., ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. 30 mm thickness Ground Floor | Sqm | 3969.76 | 3969.76 | 6.97 | False | None | None | False | None | False | 27669.2272 | 0 | 3659503 | 133529 | None | 12 97 1 P 112 Vol 2 | Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin,moulded to 3 mm thick FRP laminate for forming hollow rails and styles,with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames as per specifications., ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. 30 mm thickness First Floor | Sqm | 3969.76 | 3969.76 | 6.97 | False | None | None | False | None | False | 27669.2272 | 0 | 3659504 | 133529 | None | 12 87 P 111 Vol 2 | Providing and fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC Matching to RAL 9016 sections and with minimum Titanium Dioxide at 6 P H R with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 81mm width x 42mm height with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm The cost is inclusive of all fixtures and separate charges for minor T and P's shall not be made as per specifications., ,including cost and conveyance of all materials, cost of labour, HOM of machinery and equipment's, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc. complete and directions of the Engineer in charge of the work. Ground Floor | Sqm | 8116.69 | 8116.69 | 19.85 | False | None | None | False | None | False | 161116.2965 | 0 | 3659505 | 133529 | None | 12 87 P 111 Vol 2 | Providing and fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC Matching to RAL 9016 sections and with minimum Titanium Dioxide at 6 P H R with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 81mm width x 42mm height with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm The cost is inclusive of all fixtures and separate charges for minor T and P's shall not be made as per specifications., ,including cost and conveyance of all materials, cost of labour, HOM of machinery and equipment's, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc. complete and directions of the Engineer in charge of the work. First Floor | Sqm | 8116.69 | 8116.69 | 19.24 | False | None | None | False | None | False | 156165.1156 | 0 | 3659506 | 133529 | None | 11 34 B P 86 Vol 2 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.Ground Floor | Kg | 226.74 | 226.74 | 1155.05 | False | None | None | False | None | False | 261896.037 | 0 | 3659507 | 133529 | None | 11 34 B P 86 Vol 2 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.First Floor | Kg | 226.74 | 226.74 | 404.14 | False | None | None | False | None | False | 91634.7036 | 0 | 3659508 | 133529 | None | 11 28 P 85 Vol 2 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Kg | 700.04 | 700.04 | 969.26 | False | None | None | False | None | False | 678520.7704 | 0 | 3659509 | 133529 | None | 18 7 P 184 Vol 2 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Sqm | 9852.53 | 9852.53 | 44.81 | False | None | None | False | None | False | 441491.8693 | 0 | 3659510 | 133529 | None | 7 17 2 P 39 BGM SR18 19 | Providing, fabricating, assembling and fixing in position aluminium doors using following aluminium mat finish or glossy finish, outer frame plain section 101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness 3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m; aluminium sections cut to length joint metredcorners grinded, the shutters pivoted opening arrangement with heavy duty aluminium alloy automatic door closures floor mounted, providing and fixing standard approved accessories, such as aluminium handle for full width or length, tower bolts, lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain glass for top and bottom panel; aluminium sections treated for removal of any rust and prevention of further rust formation, and coated with greasy materials for non-adherance of mortars or any other sticky materials; the assembled frame fitted with the corner angles, strips and fitted with screws, rawl plugs or teakwood gutties to R.C.C. columns or masonry on sides. beams and flooring in bottom. including cutting, chistling and making good with cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specifications.using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Sqm | 7706.58 | 7706.58 | 3.75 | False | None | None | False | None | False | 28899.675 | 0 | 3659511 | 133529 | None | 8 30 P 46 Vol 2 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor | Sqm | 215.59 | 215.59 | 482.28 | False | None | None | False | None | False | 103974.7452 | 0 | 3659512 | 133529 | None | 8 30 P 46 Vol 2 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor | Sqm | 217.74 | 217.74 | 398.31 | False | None | None | False | None | False | 86728.0194 | 0 | 3659513 | 133529 | None | 8 30 P 46 Vol 2 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Terrace Floor | Sqm | 219.9 | 219.9 | 101.3 | False | None | None | False | None | False | 22275.87 | 0 | 3659514 | 133529 | None | 8 54 2 8 55 2 Vol 2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.For Ceiling & Inside walls -Ground Floor | Sqm | 201.96 | 201.96 | 1007.51 | False | None | None | False | None | False | 203476.7196 | 0 | 3659515 | 133529 | None | 8 54 2 8 55 2 Vol 2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.For Ceiling & Inside walls -First Floor | Sqm | 201.96 | 201.96 | 638.39 | False | None | None | False | None | False | 128929.2444 | 0 | 3659516 | 133529 | None | 8 54 2 8 55 2 Vol 2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.For Ceiling & Inside walls -Terrace Floor | Sqm | 201.96 | 201.96 | 80.3 | False | None | None | False | None | False | 16217.388 | 0 | 3659517 | 133529 | None | 8 41 P 48 Vol 2 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.-Ground Floor | Sqm | 206.91 | 206.91 | 42.78 | False | None | None | False | None | False | 8851.6098 | 0 | 3659518 | 133529 | None | 8 41 P 48 Vol 2 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.-First Floor | Sqm | 208.98 | 208.98 | 39.09 | False | None | None | False | None | False | 8169.0282 | 0 | 3659519 | 133529 | None | 8 3 1 P 41 Vol 2 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.For Flagging | Sqm | 438.61 | 438.61 | 106.19 | False | None | None | False | None | False | 46575.9959 | 0 | 3659520 | 133529 | None | 8 79 P 54 Vol 2 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.: 10mm to 15 mm wide and 8 mm deep groove. | m | 64.43 | 64.43 | 1260.94 | False | None | None | False | None | False | 81242.3642 | 0 | 3659521 | 133529 | None | 8 84 P 55 Vol 2 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete as per specification.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Each | 588.53 | 588.53 | 10.75 | False | None | None | False | None | False | 6326.6975 | 0 | 3659522 | 133529 | None | 8 3 P 63 Vol 3 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | cm | 1.98 | 1.98 | 10000.0 | False | None | None | False | None | False | 19800.0 | 0 | 3659523 | 133529 | None | 8 40 P 48 Vol 2 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Sqm | 142.48 | 142.48 | 10.6 | False | None | None | False | None | False | 1510.288 | 0 | 3659524 | 133529 | None | 15 2 P 149 Vol 2 | Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Sqm | 913.14 | 913.14 | 610.65 | False | None | None | False | None | False | 557608.941 | 0 | 3659525 | 133529 | None | 4 1 P 5 Vol 2 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Sqm | 146.2 | 146.2 | 482.37 | False | None | None | False | None | False | 70522.494 | 0 | 3659526 | 133529 | None | 10 2 P 69 Vol 2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | m | 406.39 | 406.39 | 105.35 | False | None | None | False | None | False | 42813.1865 | 0 | 3659527 | 133529 | None | NSR-3 | Providing and fixing of Signage boards etc. complete with all lead, lifts, loading, unloading, scaffolding arrangement, including cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work. | Each | 112100.0 | 112100.0 | 1.0 | False | None | None | False | None | False | 112100.0 | 0 | 3659528 | 133529 | None | 12 68 1 P 106 Vol 2 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. 125x65x2.12mm, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Nos | 68.14 | 68.14 | 48.0 | False | None | None | False | None | False | 3270.72 | 0 | 3659529 | 133529 | None | 12 68 2 P 106 Vol 2 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. 100x58x1.9mm.,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Nos | 53.28 | 53.28 | 42.0 | False | None | None | False | None | False | 2237.76 | 0 | 3659530 | 133529 | None | 12 72 P 107 Vol 2 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Nos | 101.6 | 101.6 | 60.0 | False | None | None | False | None | False | 6096.0 | 0 | 3659531 | 133529 | None | 12 73 1 P 107 Vol 2 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125mm as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Nos | 54.52 | 54.52 | 60.0 | False | None | None | False | None | False | 3271.2 | 0 | 3659532 | 133529 | None | 12 58 P 105 Vol 2 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Nos | 148.68 | 148.68 | 21.0 | False | None | None | False | None | False | 3122.28 | 0 | 3659533 | 133529 | None | 22 15 3 P 218 Vol 2 | Providing and fixing Aldrops for door shutters with necessary screws, etc. complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Nos | 371.7 | 371.7 | 30.0 | False | None | None | False | None | False | 11151.0 | 0 | 3659534 | 133529 | None | 589 A 30 Vol 2 21 22 SR | Providing and fixing teak wood beading for door shutters complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Nos | 74.34 | 74.34 | 78.0 | False | None | None | False | None | False | 5798.52 | 0 | 3659535 | 133529 | None | 9 20 2 P 62 Vol 2 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per specifications, including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. Ground Floor | Sqm | 258.95 | 258.95 | 96.22 | False | None | None | False | None | False | 24916.169 | 0 | 3659536 | 133529 | None | 9 20 2 P 62 Vol 2 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per specifications, including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. First Floor | Sqm | 261.54 | 261.54 | 101.8 | False | None | None | False | None | False | 26624.772 | 0 | 3659537 | 133529 | None | 10 15 1 P 71 Vol 2 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc.,complete as per specification. including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Sqm | 4942.37 | 4942.37 | 52.56 | False | None | None | False | None | False | 259770.9672 | 0 | 3659538 | 133529 | None | 10 10 1 P 70 Vol 2 | Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre-laminated one side decorative lamination and other side balancing lamination Grade I, Type II, IS : 12823 marked, including priming coat on unexposed arrangement and screws etc. complete : 12 mm thick, as per specification. including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Sqm | 1374.05 | 1374.05 | 37.44 | False | None | None | False | None | False | 51444.432 | 0 | 3659539 | 133529 | None | 1 6 1 P 6 Vol 1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Cum | 599.68 | 599.68 | 32.0 | False | None | None | False | None | False | 19189.76 | 0 | 3659540 | 133529 | None | 1 10 P 7 Vol 1 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead and lift, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. | Cum | 198.24 | 198.24 | 98.46 | False | None | None | False | None | False | 19518.7104 | 0 | 3659541 | 133529 | None | 13 32 3 P 122 Vol 2 | Providing and fixing Chlorinated Polyvinyl Chloride(CPVC)pipes, having thermal stability for hot & cold watersupply,including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. CPVC pipe - 25mm | m | 591.0 | 591.0 | 50.0 | False | None | None | False | None | False | 29550.0 | 0 | 3659542 | 133529 | None | 13 33 4 P 122 Vol 2 | Providing and fixing Chlorinated Polyvinyl Chloride(CPVC)pipes, having thermal stability for hot & cold watersupply,including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. External work, including cutting chases and making good the walls etc.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. CPVC pipe - 32mm | m | 460.91 | 460.91 | 90.0 | False | None | None | False | None | False | 41481.9 | 0 | 3659543 | 133529 | None | 10 14 9 P 120 Vol 5 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.(PVC pipe of 6Kgs/Sqm -75mm dia ) | m | 237.89 | 237.89 | 400.0 | False | None | None | False | None | False | 95156.0 | 0 | 3659544 | 133529 | None | 10 14 10 P 120 Vol 5 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.(PVC pipe of 6Kgs/Sqm -90mm dia ) | m | 319.66 | 319.66 | 90.0 | False | None | None | False | None | False | 28769.4 | 0 | 3659545 | 133529 | None | 10 14 11 P 120 Vol 5 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.(PVC pipe of 6Kgs/Sqm -110mm dia ) | m | 443.56 | 443.56 | 261.0 | False | None | None | False | None | False | 115769.16 | 0 | 3659546 | 133529 | None | 10 14 13 P 120 Vol 5 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.(PVC pipe of 6Kgs/Sqm -160mm dia ) | m | 800.39 | 800.39 | 90.0 | False | None | None | False | None | False | 72035.1 | 0 | 3659547 | 133529 | None | NSR-4 | Providing and fixing in position Pillar cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Each | 1475.0 | 1475.0 | 6.0 | False | None | None | False | None | False | 8850.0 | 0 | 3659548 | 133529 | None | NSR-5 | Providing and fixing in position Short body cock/tap of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Each | 1475.0 | 1475.0 | 6.0 | False | None | None | False | None | False | 8850.0 | 0 | 3659549 | 133529 | None | NSR-4 | Providing and fixing in position Long body cock/tap of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Each | 1593.0 | 1593.0 | 4.0 | False | None | None | False | None | False | 6372.0 | 0 | 3659550 | 133529 | None | NSR-7 | Providing and fixing in position Angle stop cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Each | 1475.0 | 1475.0 | 6.0 | False | None | None | False | None | False | 8850.0 | 0 | 3659551 | 133529 | None | NSR-8 | Providing and fixing in position Two way bib cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Each | 1593.0 | 1593.0 | 2.0 | False | None | None | False | None | False | 3186.0 | 0 | 3659552 | 133529 | None | NSR-9 | Providing and fixing in position Health faucet complete set of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Each | 1593.0 | 1593.0 | 2.0 | False | None | None | False | None | False | 3186.0 | 0 | 3659553 | 133529 | None | 13 46 P 124 Vol 2 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 100mminletand75mmoutlet , Hubless centrifugally cast(spun) iron epoxy coated inside & outside as per IS:15905, including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. 10.0cms x 7.5cms | Nos | 588.53 | 588.53 | 8.0 | False | None | None | False | None | False | 4708.24 | 0 | 3659554 | 133529 | None | 13 34 P 123 Vol 2 | Providing and placing on terrace (at all floor levels ) polyethylene water storagetank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittinigs and the base support for tank., including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | l | 11.15 | 11.15 | 1000.0 | False | None | None | False | None | False | 11150.0 | 0 | 3659555 | 133529 | None | 16 9 P 191 Vol 5 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Each | 6757.51 | 6757.51 | 5.0 | False | None | None | False | None | False | 33787.55 | 0 | 3659556 | 133529 | None | 16 10 191 Vol 5 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Each | 5248.4 | 5248.4 | 22.0 | False | None | None | False | None | False | 115464.8 | 0 | 3659557 | 133529 | None | 13 4 1 P 117 Vol 2 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. 25mm dia | Nos | 680.21 | 680.21 | 1.0 | False | None | None | False | None | False | 680.21 | 0 | 3659558 | 133529 | None | 13 4 2 P 117 Vol 2 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. 32mm dia | Nos | 740.92 | 740.92 | 1.0 | False | None | None | False | None | False | 740.92 | 0 | 3659559 | 133529 | None | 13 4 4 P 117 Vol 2 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. 50mm dia | Nos | 1059.35 | 1059.35 | 2.0 | False | None | None | False | None | False | 2118.7 | 0 | 3659560 | 133529 | None | 14 3 1 P 131 Vol 2 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Each | 7405.5 | 7405.5 | 2.0 | False | None | None | False | None | False | 14811.0 | 0 | 3659561 | 133529 | None | 14 1 1 P 131 Vol-2) | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Pan | 6051.28 | 6051.28 | 4.0 | False | None | None | False | None | False | 24205.12 | 0 | 3659562 | 133529 | None | 14 7 2 P 132 Vol 2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15mm C.P. brass pillar tap,,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Nos | 3173.08 | 3173.08 | 8.0 | False | None | None | False | None | False | 25384.64 | 0 | 3659563 | 133529 | None | 37 35 P 269 18 19 SR | Wall bores in Brick masonry upto 45 em thick. including cost of materials, labour, HOM complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Nos | 156.11 | 156.11 | 25.0 | False | None | None | False | None | False | 3902.75 | 0 | 3659564 | 133529 | None | 37 36 1 P 269 18 19 | Wall bores in size stone masonry. including cost of materials, labour, HOM complete as per specifications. upto 45 em thick..,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Nos | 375.42 | 375.42 | 10.0 | False | None | None | False | None | False | 3754.2 | 0 | 3659565 | 133529 | None | 302 A 21 Vol 2 21 22 SR | Providing & fixing Indian marble partitions at urnals as per specification .,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Sqm | 2292.15 | 2292.15 | 7.5 | False | None | None | False | None | False | 17191.125 | 0 | 3659566 | 133529 | None | 14 32 2 P 136 Vol 2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Nos | 1261.3 | 1261.3 | 8.0 | False | None | None | False | None | False | 10090.4 | 0 | 3659567 | 133529 | None | 14 40 2 P 137 Vol 2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Nos | 592.24 | 592.24 | 8.0 | False | None | None | False | None | False | 4737.92 | 0 | 3659568 | 133529 | None | NSR | Providing 10cms dia PVC cowl with cap of approved 1 st quality and make conforming to ISI specifications and fixing in position as directed ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Nos | 283.73 | 283.73 | 2.0 | False | None | None | False | None | False | 567.46 | 0 | 3659569 | 133529 | None | 12 111 P 90 18 19 BGM SR | Providing and fixing 7.5 cms to 15.00 cms dia NP grating 100 mm dia.. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Nos | 185.85 | 185.85 | 8.0 | False | None | None | False | None | False | 1486.8 | 0 | 3659570 | 133529 | None | 11 2 6 P 127 Vol V | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. For Medium Duty GI pipe of 50mm dia | m | 723.58 | 723.58 | 35.0 | False | None | None | False | None | False | 25325.3 | 0 | 3659571 | 133529 | None | 14 23 P 135 Vol 2 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Nos | 1429.81 | 1429.81 | 6.0 | False | None | None | False | None | False | 8578.86 | 0 | 3659572 | 133529 | None | 17 14 P 177 Vol 2 | Providing and laying 100mm thick pre-cast cover slabs over Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 500 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. Precast Slab For Chamber RCC Covers | Sqm | 1449.63 | 1449.63 | 32.15 | False | None | None | False | None | False | 46605.6045 | 0 | 3659573 | 133529 | None | 2 2 3 P 15 Vol 1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. (including cost of providing & removing formwork as per Design & Drawing) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Sump bottom slab & side RCC Walls | Cum | 8635.33 | 8635.33 | 69.18 | False | None | None | False | None | False | 597392.1294 | 0 | 3659574 | 133529 | None | 2 3 2 P 16 Vol 1 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. (including cost of providing & removing formwork as per Design & Drawing) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Sump Roofslab | Cum | 12043.08 | 12043.08 | 7.86 | False | None | None | False | None | False | 94658.6088 | 0 | 3659575 | 133529 | None | 8 6 2 P 42 Vol 2 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Sqm | 531.53 | 531.53 | 259.98 | False | None | None | False | None | False | 138187.1694 | 0 | 3659576 | 133529 | None | 7 3 P 85 Vol V | Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Each | 2651.46 | 2651.46 | 1.0 | False | None | None | False | None | False | 2651.46 | 0 | 3659577 | 133529 | None | 7 1 2 P 85 Vol V | Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle of 65 x 65 x 10mm ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | m | 5948.44 | 5948.44 | 4.5 | False | None | None | False | None | False | 26767.98 | 0 | 3659578 | 133529 | None | 5 1 P 25 18 19 BGMSR | Providing and constructing granite I trap I basalt rubble stone masonry in foundation with mud mortar (uncoursed), bond stones at 2m. apart in each course including cost of materials, labour, curing complete as per specifications. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. For Soak pit steaning wall | Cum | 2899.26 | 2899.26 | 11.93 | False | None | None | False | None | False | 34588.1718 | 0 | 3659579 | 133529 | None | 1 23 P 11 Vol 1 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. For Soak pit | Cum | 3323.0 | 3323.0 | 11.55 | False | None | None | False | None | False | 38380.65 | 0 | 3659580 | 133529 | None | 1 11 P 7 Vol 1 21 22 SR | Supplying and filling in plinth with sand under floors, foundation of Bridges including watering, ramming, consolidating and dressing complete.,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. For Soak pit | Cum | 2697.3 | 2697.3 | 3.12 | False | None | None | False | None | False | 8415.576 | 0 | 3659581 | 133529 | None | 2 4 3 P 17 Vol 1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates., including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work. For Compound wall Grade beam | Cum | 8635.33 | 8635.33 | 7.76 | False | None | None | False | None | False | 67010.1608 | 0 | 3659582 | 133529 | None | 8 37 P 48 Vol 2 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two coats) including a coat of approved steel primer but excluding a coat of mordant solution including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications ,including curing, cost and conveyance of all materials, cost of labour,HOM of machinery and equipments, with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and directions of the Engineer in-charge of the work.For Compound wall Gate | Sqm | 162.31 | 162.31 | 21.6 | False | None | None | False | None | False | 3505.896 | 0 | 3659583 | 133529 | None | 3 11 P 18 Vol 3 | Preparation and surface treatment of formation by removing mud and slurry, watering to the extent needed to maintain the desired moisture content, trimming to the required line, grade, profile and rolling with 8-10 t smooth wheeled roller, complete as per clause 310. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Sqm | 4.96 | 4.96 | 302.5 | False | None | None | False | None | False | 1500.4 | 0 | 3659584 | 133529 | None | 3 6 P 17 Vol 3 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads,transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Cum | 610.83 | 610.83 | 90.75 | False | None | None | False | None | False | 55432.8225 | 0 | 3659585 | 133529 | None | 4 17 P 26 Vol 3 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Cum | 3170.6 | 3170.6 | 37.13 | False | None | None | False | None | False | 117724.378 | 0 | 3659586 | 133529 | None | 4 1 V P 23 Vol 3 | Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -V Material ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Cum | 3081.39 | 3081.39 | 37.13 | False | None | None | False | None | False | 114412.0107 | 0 | 3659587 | 133529 | None | 6 6 P 51 Vol 3 | Construction of un-reinforced plain cement concrete pavement using RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90 kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base. The superplastisiser confirming to IS 9103-1999 Reaffirmed-2008 ,Coarse aggregates and Fine aggregate confirming to IS:383-2016, transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film,
wedges, steel plates including levelling the form work). Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth
finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work. (Groove cutting shall be paid seperately) ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Cum | 8392.99 | 8392.99 | 49.5 | False | None | None | False | None | False | 415453.005 | 0 | 3659588 | 133529 | None | 22 8 1 PWD 18 19 BGM SR | Providing groove cutting for width of 5mm to 1Omm and depth 80mm-100mm including cost of cutting machine, generator & HOM, including cost of blade, coolant etc., including cleaning of groove & providing sand and hot bitumen fillars, and filler metal etc. , including cost of conveyance of all materials, labour, lead and lift charges and all other incidental charges as per drawing and as per specifications.-for concrete pavement ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | m | 167.27 | 167.27 | 81.0 | False | None | None | False | None | False | 13548.87 | 0 | 3659589 | 133529 | None | 9 32 P 64 Vol 2 21 22 SR | Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Sqm | 1418.66 | 1418.66 | 427.5 | False | None | None | False | None | False | 606477.15 | 0 | 3659590 | 133529 | None | 12 4 P 140 Vol 5 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped,probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Each | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3659591 | 133529 | None | 12 2 1 P 139 Vol 5 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Up to 0.00 to 50.00 mtrs ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | m | 382.85 | 382.85 | 50.0 | False | None | None | False | None | False | 19142.5 | 0 | 3659592 | 133529 | None | 12 2 2 P 139 Vol 5 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Up to 50.00 to 100.00 mtrs ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | m | 479.49 | 479.49 | 50.0 | False | None | None | False | None | False | 23974.5 | 0 | 3659593 | 133529 | None | 12 2 3 P 139 Vol 5 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: Up to 100.00 to 150.00 mtrs ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | m | 510.47 | 510.47 | 50.0 | False | None | None | False | None | False | 25523.5 | 0 | 3659594 | 133529 | None | 12 32 P 143 Vol 5 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | m | 2394.99 | 2394.99 | 20.0 | False | None | None | False | None | False | 47899.8 | 0 | 3659595 | 133529 | None | 12 33 P 143 Vol 5 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments ,including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. | Each | 185.85 | 185.85 | 6.0 | False | None | None | False | None | False | 1115.1 | 0 | 3659596 | 133529 | None | 12 34 P 143 Vol 5 | Providing and laying at site of work MS casing caps as per IS 1239 (partII) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Each | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3659597 | 133529 | None | Page 1 1 2 1 Vol 6 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia. mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick | m | 77.88 | 77.88 | 360.0 | False | None | None | False | None | False | 28036.8 | 0 | 3659598 | 133529 | None | Page 1 1 2 2 Vol 6 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia. mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick | m | 92.04 | 92.04 | 420.0 | False | None | None | False | None | False | 38656.8 | 0 | 3659599 | 133529 | None | Page 1 1 2 3 Vol 6 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe 32 mm dia 2.5 mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 32 mm dia 2.5 mm thick | m | 125.08 | 125.08 | 120.0 | False | None | None | False | None | False | 15009.6 | 0 | 3659600 | 133529 | None | Page 2 1 11 P 1 | Supplying And Fixing M.S. Rafter Clamp Set made out of M.S. Flat and 14 mm M.S. rod. | No | 187.62 | 187.62 | 12.0 | False | None | None | False | None | False | 2251.44 | 0 | 3659601 | 133529 | None | Page 3 1 12 Vol 6 | Supplying And Fixing M.S. Rafter Clamp Set made out of M.S. Flat and 14 mm M.S. rod. | No | 188.8 | 188.8 | 11.0 | False | None | None | False | None | False | 2076.8 | 0 | 3659602 | 133529 | None | Page 1 1 3 1 Vol 6 | Supplying heavy gauge PVC Conduit Pipe 19/20 mm dia 2 mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick | m | 80.24 | 80.24 | 220.0 | False | None | None | False | None | False | 17652.8 | 0 | 3659603 | 133529 | None | Page 1 1 3 2 Vol 6 | Supplying heavy gauge PVC Conduit Pipe 25 mm dia 2 mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick | m | 93.22 | 93.22 | 320.0 | False | None | None | False | None | False | 29830.4 | 0 | 3659604 | 133529 | None | Page 17 5 19 8 Vol 6 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.-8 Way SP & N | Each | 2187.72 | 2187.72 | 3.0 | False | None | None | False | None | False | 6563.16 | 0 | 3659605 | 133529 | None | Page 7 3 4 1 Vol 6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2 Way | Each | 162.84 | 162.84 | 12.0 | False | None | None | False | None | False | 1954.08 | 0 | 3659606 | 133529 | None | Page 7 3 4 2 Vol 6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 Way | Each | 187.62 | 187.62 | 14.0 | False | None | None | False | None | False | 2626.68 | 0 | 3659607 | 133529 | None | Page 7 3 4 3 Vol 6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way | Each | 208.86 | 208.86 | 8.0 | False | None | None | False | None | False | 1670.88 | 0 | 3659608 | 133529 | None | Page 7 3 4 4 Vol 6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way | Each | 259.6 | 259.6 | 8.0 | False | None | None | False | None | False | 2076.8 | 0 | 3659609 | 133529 | None | Page 7 3 4 5 Vol 6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way | Each | 307.98 | 307.98 | 12.0 | False | None | None | False | None | False | 3695.76 | 0 | 3659610 | 133529 | None | Page 7 3 4 6 Vol 6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 10-12 Way | Each | 376.42 | 376.42 | 8.0 | False | None | None | False | None | False | 3011.36 | 0 | 3659611 | 133529 | None | Page 7 3 4 7 Vol 6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 16 Way | Each | 428.34 | 428.34 | 10.0 | False | None | None | False | None | False | 4283.4 | 0 | 3659612 | 133529 | None | Page 4 2 2 1 Vol 6 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box | Point | 317.42 | 317.42 | 22.0 | False | None | None | False | None | False | 6983.24 | 0 | 3659613 | 133529 | None | Page 4 2 2 2 Vol 6 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box | Point | 447.22 | 447.22 | 45.0 | False | None | None | False | None | False | 20124.9 | 0 | 3659614 | 133529 | None | Page 4 2 2 3 Vol 6 | Supplying and wiring adopting loop system in existing PVC Conduit
/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box | Point | 654.9 | 654.9 | 50.0 | False | None | None | False | None | False | 32745.0 | 0 | 3659615 | 133529 | None | Page 4 2 3 2 Vol 6 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 1.5 mm2 | m | 30.68 | 30.68 | 1600.0 | False | None | None | False | None | False | 49088.0 | 0 | 3659616 | 133529 | None | Page 4 2 3 3 Vol 6 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2 | m | 49.56 | 49.56 | 3200.0 | False | None | None | False | None | False | 158592.0 | 0 | 3659617 | 133529 | None | Page 4 2 3 4 Vol 6 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2 | m | 74.34 | 74.34 | 600.0 | False | None | None | False | None | False | 44604.0 | 0 | 3659618 | 133529 | None | Page 4 2 3 5 Vol 6 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6 mm2 | m | 108.56 | 108.56 | 270.0 | False | None | None | False | None | False | 29311.2 | 0 | 3659619 | 133529 | None | Page 7 3 5 1 Vol 6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 1 to 2 Module | Each | 161.66 | 161.66 | 12.0 | False | None | None | False | None | False | 1939.92 | 0 | 3659620 | 133529 | None | Page 7 3 5 2 Vol 6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 3 Module | Each | 189.98 | 189.98 | 14.0 | False | None | None | False | None | False | 2659.72 | 0 | 3659621 | 133529 | None | Page 7 3 5 3 Vol 6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module | Each | 206.5 | 206.5 | 8.0 | False | None | None | False | None | False | 1652.0 | 0 | 3659622 | 133529 | None | Page 7 3 5 4 Vol 6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module | Each | 276.12 | 276.12 | 8.0 | False | None | None | False | None | False | 2208.96 | 0 | 3659623 | 133529 | None | Page 7 3 5 5 Vol 6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Each | 335.12 | 335.12 | 12.0 | False | None | None | False | None | False | 4021.44 | 0 | 3659624 | 133529 | None | Page 7 3 5 6 Vol 6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 10-12 Module | Each | 405.92 | 405.92 | 8.0 | False | None | None | False | None | False | 3247.36 | 0 | 3659625 | 133529 | None | Page 7 3 5 7 Vol 6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. Make - Group "A" materials and as per the directions of Engineer in charge of the work. 16-18 Module | Each | 468.46 | 468.46 | 10.0 | False | None | None | False | None | False | 4684.6 | 0 | 3659626 | 133529 | None | Page 8 3 6 1 Vol 6 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 120.36 | 120.36 | 156.0 | False | None | None | False | None | False | 18776.16 | 0 | 3659627 | 133529 | None | Page 8 3 6 2 Vol 6 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way Switch | Each | 195.88 | 195.88 | 8.0 | False | None | None | False | None | False | 1567.04 | 0 | 3659628 | 133529 | None | Page 8 3 6 3 Vol 6 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket | Each | 201.78 | 201.78 | 46.0 | False | None | None | False | None | False | 9281.88 | 0 | 3659629 | 133529 | None | Page 8 3 6 4 Vol 6 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module | Each | 421.26 | 421.26 | 19.0 | False | None | None | False | None | False | 8003.94 | 0 | 3659630 | 133529 | None | Page 8 3 6 10 Vol 6 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket | Each | 278.48 | 278.48 | 4.0 | False | None | None | False | None | False | 1113.92 | 0 | 3659631 | 133529 | None | Page 8 3 6 10 Vol 6 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket | Each | 278.48 | 278.48 | 4.0 | False | None | None | False | None | False | 1113.92 | 0 | 3659632 | 133529 | None | Page 9 3 14 7 Vol 6 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Batten Holder | No | 87.32 | 87.32 | 56.0 | False | None | None | False | None | False | 4889.92 | 0 | 3659633 | 133529 | None | Page 29 6 1 Vol 6 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. | Each | 1760.56 | 1760.56 | 6.0 | False | None | None | False | None | False | 10563.36 | 0 | 3659634 | 133529 | None | Page 29 6 3 1 Vol 6 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model | Each | 3521.12 | 3521.12 | 19.0 | False | None | None | False | None | False | 66901.28 | 0 | 3659635 | 133529 | None | Page 30 6 7 2 Vol 6 | Supplying ......TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 1.5 Ton capacity | Each | 56265.94 | 56265.94 | 1.0 | False | None | None | False | None | False | 56265.94 | 0 | 3659636 | 133529 | None | Page 31 6 11 Vol 6 | Installation charges for 1 to 2 Ton capacity window type Air Conditioner with 50 x 75 mm thick teak wood frame of suitable size and allied works complete. | Each | 3163.58 | 3163.58 | 1.0 | False | None | None | False | None | False | 3163.58 | 0 | 3659637 | 133529 | None | Page 43 11 4 4 Vol 6 | Supplying of recess mounting non integrated type LED down light 24 W luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power COB with CCT 6500 degree K, CRI greater than 70 percentage. efficacy greater than 100 lumen per W, 120 degree beam spread, life greater than 25000 burning hours and Compliance to IS10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should greater than 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical | No | 2044.94 | 2044.94 | 10.0 | False | None | None | False | None | False | 20449.4 | 0 | 3659638 | 133529 | None | Page 44 11 6 3 Vol 6 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 100 lumen per watt, 120degree beam spread, life greater than 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should greater than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' 36 W | No | 5372.54 | 5372.54 | 9.0 | False | None | None | False | None | False | 48352.86 | 0 | 3659639 | 133529 | None | Page 42 11 3 2 Vol 6 | Supplying of 4 feet 20 22 Watt -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70% lumen maintenance with CRI greater than 80. Power Input: 220- 240V@ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED light fitting 1 x 4' - 20 22 W | Each | 814.2 | 814.2 | 44.0 | False | None | None | False | None | False | 35824.8 | 0 | 3659640 | 133529 | None | Page 46 11 11 4 Vol 6 | Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp Wage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.9W, 6500K | Each | 181.72 | 181.72 | 22.0 | False | None | None | False | None | False | 3997.84 | 0 | 3659641 | 133529 | None | Page 55 13 7 1 Vol 6 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall/ ceiling / Rafter / Girders | Each | 143.96 | 143.96 | 70.0 | False | None | None | False | None | False | 10077.2 | 0 | 3659642 | 133529 | None | Page 56 13 10 Vol 6 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 22.0 | False | None | None | False | None | False | 4439.16 | 0 | 3659643 | 133529 | None | Page 56 13 12 Vol 6 | Extra length of GI pipe of class B 19 mm dia for down rod. | m | 232.46 | 232.46 | 9.0 | False | None | None | False | None | False | 2092.14 | 0 | 3659644 | 133529 | None | Page 56 13 14 Vol 6 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 580.56 | 580.56 | 4.0 | False | None | None | False | None | False | 2322.24 | 0 | 3659645 | 133529 | None | Page 47 12 2 3 Vol 6 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Remote Controled | Each | 1404.2 | 1404.2 | 2.0 | False | None | None | False | None | False | 2808.4 | 0 | 3659646 | 133529 | None | Page 16 5 18 4 Vol 6 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6-32 A DP | Each | 872.02 | 872.02 | 12.0 | False | None | None | False | None | False | 10464.24 | 0 | 3659647 | 133529 | None | Page 17 5 20 1 Vol 6 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16A-25A 2 pole | Each | 5046.86 | 5046.86 | 3.0 | False | None | None | False | None | False | 15140.58 | 0 | 3659648 | 133529 | None | Page 37 9 2 5 Vol 6 | Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. | Each | 47079.64 | 47079.64 | 1.0 | False | None | None | False | None | False | 47079.64 | 0 | 3659649 | 133529 | None | Page 37 9 4 4 P 1 | Supplying, installation, testing & commissioning of 12V 100 AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type.100 AH capacity. | Each | 23756.94 | 23756.94 | 10.0 | False | None | None | False | None | False | 237569.4 | 0 | 3659650 | 133529 | None | Page 8 3 6 11 Vol 6 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket | Each | 184.08 | 184.08 | 6.0 | False | None | None | False | None | False | 1104.48 | 0 | 3659651 | 133529 | None | Page 8 3 6 12 Vol 6 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. RJ45/I.O Outlet Cat-6 | Each | 397.66 | 397.66 | 12.0 | False | None | None | False | None | False | 4771.92 | 0 | 3659652 | 133529 | None | Page 35 8 1 Vol 6 | Supplying and drawing UTP-CAT 6E LAN cable. | Mtr | 44.84 | 44.84 | 800.0 | False | None | None | False | None | False | 35872.0 | 0 | 3659653 | 133529 | None | Page 35 8 2 2 Vol 6 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pair | m | 24.78 | 24.78 | 180.0 | False | None | None | False | None | False | 4460.4 | 0 | 3659654 | 133529 | None | Page 35 8 3 Vol 6 | Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. | m | 51.92 | 51.92 | 80.0 | False | None | None | False | None | False | 4153.6 | 0 | 3659655 | 133529 | None | Page 28 8 4 1 P 1 | Supplying & Fixing of switch mounting rack with power manager & Cable manager. 4U with 450 mm depth | Each | 3443.24 | 3443.24 | 1.0 | False | None | None | False | None | False | 3443.24 | 0 | 3659656 | 133529 | None | Page 35 8 4 1 Vol 6 | Supplying & Fixing of switch mounting rack with power manager & Cable manager. 4U with 450 mm depth | Each | 5772.56 | 5772.56 | 2.0 | False | None | None | False | None | False | 11545.12 | 0 | 3659657 | 133529 | None | Page 35 8 9 5 Vol 6 | Supplying fixing of Network Switches. 24 port 10/100 Switch | Each | 5546.0 | 5546.0 | 12.0 | False | None | None | False | None | False | 66552.0 | 0 | 3659658 | 133529 | None | Page 35 8 10 1 Vol 6 | Supplying & fixing of I/O socket with back box. Single I/O | Each | 578.2 | 578.2 | 12.0 | False | None | None | False | None | False | 6938.4 | 0 | 3659659 | 133529 | None | Page 36 8 11 3 Vol 6 | Supplying & Fixing of ... Mtrs Cat 6 Patch Cable. 3mtr | Each | 390.58 | 390.58 | 1.0 | False | None | None | False | None | False | 390.58 | 0 | 3659660 | 133529 | None | Page 36 8 13 2 Vol 6 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 20 Pair | m | 451.94 | 451.94 | 1.0 | False | None | None | False | None | False | 451.94 | 0 | 3659661 | 133529 | None | Page 17 5 7 3 Vol 6 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 63 Amps | Each | 473.18 | 473.18 | 6.0 | False | None | None | False | None | False | 2839.08 | 0 | 3659662 | 133529 | None | Page 14 5 12 2 Vol 6 | Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 100 A | Each | 10070.12 | 10070.12 | 1.0 | False | None | None | False | None | False | 10070.12 | 0 | 3659663 | 133529 | None | Page 16 5 15 9 Vol 6 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.100 A 25 kA | Each | 10014.66 | 10014.66 | 1.0 | False | None | None | False | None | False | 10014.66 | 0 | 3659664 | 133529 | None | Page 16 5 18 7 Vol 6 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6-32 A TPN | Each | 2026.06 | 2026.06 | 5.0 | False | None | None | False | None | False | 10130.3 | 0 | 3659665 | 133529 | None | Page 17 5 21 Vol 6 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3659666 | 133529 | None | Page 18 5 29 Vol 6 | Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter | Each | 1681.5 | 1681.5 | 1.0 | False | None | None | False | None | False | 1681.5 | 0 | 3659667 | 133529 | None | Page 18 5 34 Vol 6 | Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. | Each | 663.16 | 663.16 | 3.0 | False | None | None | False | None | False | 1989.48 | 0 | 3659668 | 133529 | None | Page 18 5 38 Vol 6 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3659669 | 133529 | None | Page 19 5 40 1 Vol 6 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete-100 A 4 x 30 x 6 mm Aluminium Strips | m | 2908.7 | 2908.7 | 0.75 | False | None | None | False | None | False | 2181.525 | 0 | 3659670 | 133529 | None | Page 19 5 41 1 Vol 6 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint-40 x 40 x 6 mm | m | 359.9 | 359.9 | 8.0 | False | None | None | False | None | False | 2879.2 | 0 | 3659671 | 133529 | None | Page 19 5 42 2 Vol 6 | Fabricating supplying and mounting MS box made out SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete-16 SWG | Sqm | 0.51 | 0.51 | 56000.0 | False | None | None | False | None | False | 28560.0 | 0 | 3659672 | 133529 | None | Page 2 1 9 2 Vol 6 | Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm | m | 25.96 | 25.96 | 18.0 | False | None | None | False | None | False | 467.28 | 0 | 3659673 | 133529 | None | Page 54 12 58 2 Vol 6 | GI/Copper strips for grounding connections, using necessary fixing materials as required.25 x 3 mm GI strip | m | 96.76 | 96.76 | 12.0 | False | None | None | False | None | False | 1161.12 | 0 | 3659674 | 133529 | None | Page 54 12 60 2 Vol 6 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm | No | 7351.4 | 7351.4 | 6.0 | False | None | None | False | None | False | 44108.4 | 0 | 3659675 | 133529 | None | ESR Page 12 32 02 Vol 6 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 Part 1 or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 2 Core, 9 GI Strips - 4 x 0.8 mm. | Km | 93493.76 | 93493.76 | 0.08 | False | None | None | False | None | False | 7479.5008 | 0 | 3659676 | 133529 | None | ESR Page 12 32 05 Vol 6 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 4 core 16 sq mm | Km | 167373.56 | 167373.56 | 0.09 | False | None | None | False | None | False | 15063.6204 | 0 | 3659677 | 133529 | None | ESR Page 21 32 11 Vol 6 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975. 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) | Km | 211188.14 | 211188.14 | 0.21 | False | None | None | False | None | False | 44349.5094 | 0 | 3659678 | 133529 | None | ESR Page 60 21 05 Vol 6 | Laying of LT cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 2.5 to 25 Sqmm | Km | 24645.48 | 24645.48 | 0.17 | False | None | None | False | None | False | 4189.7316 | 0 | 3659679 | 133529 | None | ESR Page 60 21 06 Vol 6 | Laying of LT cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 35 to 95 Sqmm | Km | 36744.02 | 36744.02 | 0.21 | False | None | None | False | None | False | 7716.2442 | 0 | 3659680 | 133529 | None | CSR Page 6 1 6 1 Vol 1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m | m | 571.12 | 571.12 | 270.0 | False | None | None | False | None | False | 154202.4 | 0 | 3659681 | 133529 | None | CSR Page 95 9 1 1 Vol 5 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used.For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm dia | m | 223.02 | 223.02 | 30.0 | False | None | None | False | None | False | 6690.6 | 0 | 3659682 | 133529 | None | CSR Page 159 Sl no 39 Vol 4 | GI pipe iv) 50 mm dia B class | m | 359.9 | 359.9 | 8.0 | False | None | None | False | None | False | 2879.2 | 0 | 3659683 | 133529 | None | ESR Page 36 63 03 Vol 6 | Supplying and fixing of heavy duty Brass Cable Gland. 45 mm dia | Each | 232.46 | 232.46 | 6.0 | False | None | None | False | None | False | 1394.76 | 0 | 3659684 | 133529 | None | ESR Page 23 35 01 Vol 6 | Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable. Up to 4C x 50 Sqmm | Set | 382.32 | 382.32 | 4.0 | False | None | None | False | None | False | 1529.28 | 0 | 3659685 | 133529 | None | Page 44 11 7 2 Vol 6 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr@ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/1 EC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency greater than1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.. LED Post Top Lantern with 25/30 W for gate | No | 9111.96 | 9111.96 | 2.0 | False | None | None | False | None | False | 18223.92 | 0 | 3659686 | 133529 | None | Page 45 11 8 3 Vol 6 | Supply of 70 watts LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning hrs. 50000 hr. at Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment and impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree/Nichia/ Lumileds/Osram make LED Source. | No | 7070.56 | 7070.56 | 8.0 | False | None | None | False | None | False | 56564.48 | 0 | 3659687 | 133529 | None | Page 55 13 1 1 Vol 6 | Supplying and Fixing of mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires.Using 25mm dia G.I.Pipe | Each | 1154.04 | 1154.04 | 8.0 | False | None | None | False | None | False | 9232.32 | 0 | 3659688 | 133529 | None | CSR page 157 13 40 3 Vol 5 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 3 HP, size 50x40 Head 30M, Discharge 198 LPM | Each | 20051.74 | 20051.74 | 2.0 | False | None | None | False | None | False | 40103.48 | 0 | 3659689 | 133529 | None | CSR page 152 13 13 5 Vol 5 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. 5.00 HP - 120 LPM @ 88 m = 14 STG Outlet Dia - 2.00" | Each | 36366.42 | 36366.42 | 1.0 | False | None | None | False | None | False | 36366.42 | 0 | 3659690 | 133529 | None | Page 6 2 6 1 Vol 6 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 2.5 sq mm | m | 138.06 | 138.06 | 300.0 | False | None | None | False | None | False | 41418.0 | 0 | 3659691 | 133529 | None | CSR page 155 13 28 Vol 5 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | m | 649.0 | 649.0 | 140.0 | False | None | None | False | None | False | 90860.0 | 0 | 3659692 | 133529 | None | Page 155 13 23 1 Vol 5 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE:
1) DOL- Direct Online Starter Upto 3 HP pumps | Each | 7670.0 | 7670.0 | 1.0 | False | None | None | False | None | False | 7670.0 | 0 | 3659693 | 133529 | None | Page 155 13 23 2 Vol 5 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE:
1) DOL- Direct Online Starter 3 to 6 HP pumps | Each | 11269.0 | 11269.0 | 1.0 | False | None | None | False | None | False | 11269.0 | 0 | 3659694 | 133529 | None | CSR Page 154 13 24 1 Vol 5 | Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments 50 mm dia. | No | 1475.0 | 1475.0 | 2.0 | False | None | None | False | None | False | 2950.0 | 0 | 3659695 | 133529 | None | CSR Page 154 13 25 1 Vol 5 | Supply and delivery at site of brand new best makeNon -return valve as per IS 778/1984 with ISI Mark and as per its latest amendments 50 mm dia. | No | 1475.0 | 1475.0 | 2.0 | False | None | None | False | None | False | 2950.0 | 0 | 3659696 | 133529 | None | CSR Page 155 13 29 Vol 5 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets | Set | 1829.0 | 1829.0 | 1.0 | False | None | None | False | None | False | 1829.0 | 0 | 3659697 | 133529 | None | ESR Page 158 1 Vol 6 | Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineerin- charge of works as per the standard procedure. | Cum | 462.56 | 462.56 | 2.0 | False | None | None | False | None | False | 925.12 | 0 | 3659698 | 133529 | None | ESR Page 158 5 Vol 6 | Supplying and Providing Pre cast Cable Route/ Joint marker using M15 grade Concrete, MS rods of approved size/shape (as per the approved drawings) to be laid in UG cable works. The rate includes the cost of material, labour charges, loading, unloading, handling, transportation charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineer-in-charge of works as per the standard procedure. | No | 462.56 | 462.56 | 8.0 | False | None | None | False | None | False | 3700.48 | 0 | 3659699 | 133529 | None | CSR Page 95 11 58 Vol 2 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerin- charge. (Made of G.I. wire of dia 4 mm). | Sqm | 947.54 | 947.54 | 36.0 | False | None | None | False | None | False | 34111.44 | 0 | 3659700 | 133529 | None | CSR Page 96 11 62 Vol 2 | Providing and fixing RCC precast fencing pole of size 0.15mx0.15mx2.0m casted in M 20 with 20mm down size aggregates making holes for drawing barbed wire at 30 cm c/c using 8 mm dia vertical 4 TMT steel rods and 6 mm dia stirups at 15 cm c/c fixed 1.5 m above Ground level using steel moulding , curing , transportation to work spot including excavation in all types of soil, fixing in plain cement concrete M15 using 20 mm downsize aggregate including aligning to plumb and line providing including cost of all materials, labour,usage charges of machinery complete. | Each | 1280.3 | 1280.3 | 6.0 | False | None | None | False | None | False | 7681.8 | 0 | 3659701 | 133529 | None | Page 19 5 41 1 Vol 6 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm | m | 359.9 | 359.9 | 24.0 | False | None | None | False | None | False | 8637.6 | 0 | 3659702 | 133529 | None | Page 53 12 56 Vol 6 | Supplying, fixing, wiring, earth electrode for grounding conduits,I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as perlSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | No | 4141.8 | 4141.8 | 4.0 | False | None | None | False | None | False | 16567.2 | 0 | 3659703 | 133529 | None | Page 54 12 58 2 Vol 6 | GI/Copper strips for grounding connections, using necessary fixing materials as required.25 x 3 mm GI strip | m | 96.76 | 96.76 | 12.0 | False | None | None | False | None | False | 1161.12 | 0 | 3659704 | 133529 | None | BESCOM Cost Data Sheet 25 | Erection of 3 Phase, 11kV/ 433V, 63 kVA BEE 5 Star Rated Distribution Transformer Centre Using 9 mtr. RCC Pole DPTC | No | 330834.24 | 330834.24 | 1.0 | False | None | None | False | None | False | 330834.24 | 0 | 3659705 | 133529 | None | Bescom SR 2021 22 CDS 15 | Providing 2 Pole Structrue at the Tapping Point Using RCC Pole with GOS sytem | Set | 74517.0 | 74517.0 | 1.0 | False | None | None | False | None | False | 74517.0 | 0 | 3659706 | 133529 | None | Bescom SR 2021 22 CDS 16 | Guy Set With No. 15 Strain Insulator Complete set. | Set | 1585.92 | 1585.92 | 1.0 | False | None | None | False | None | False | 1585.92 | 0 | 3659707 | 133529 | None | Bescom SR 2023 24 1 01 | Supplying RCC Pole - 9 Mtr Long, 145 Kg WL (Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785 ,as per the directions of Engineer in charge of the work. | Each | 8349.68 | 8349.68 | 6.0 | False | None | None | False | None | False | 50098.08 | 0 | 3659708 | 133529 | None | Bescom SR 2023 24 2 02 | Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth complete ,as per the directions of Engineer in charge of the work. | Each | 1313.34 | 1313.34 | 6.0 | False | None | None | False | None | False | 7880.04 | 0 | 3659709 | 133529 | None | Bescom SR 2023 24 7 02 | Supplying of Rabbit ACSR Conductor (6/3.35 mm Al + 1/3.35 mm St) with 1.5% sag.. as per IS-398 (Part - 2/1996) , Std Wt : 214 kgs/km ,as per the directions of Engineer in charge of the work. | Km | 54556.12 | 54556.12 | 0.72 | False | None | None | False | None | False | 39280.4064 | 0 | 3659710 | 133529 | None | Bescom SR 2023 24 6 01 | Stringing of conductor squirrel, weasel, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps ,as per the directions of Engineer in charge of the work. | Km | 3752.4 | 3752.4 | 0.72 | False | None | None | False | None | False | 2701.728 | 0 | 3659711 | 133529 | None | Bescom SR 2023 24 2 01 | Supplying & fixing of 11 kV, Horizontal Cross Arm - Mild Steel (MS) (Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018) | No | 438.96 | 438.96 | 2.0 | False | None | None | False | None | False | 877.92 | 0 | 3659712 | 133529 | None | Bescom SR 2023 24 2 06 | Supplying & Fixing LT 4 Pin Cross Arm - with GI pins etc complete. | No | 447.22 | 447.22 | 2.0 | False | None | None | False | None | False | 894.44 | 0 | 3659713 | 133529 | None | Bescom SR 2021 22 6 05 | Supplying and fixing 11 kV Pin insulators with GI pins etc, complete ,as per the directions of Engineer in charge of the work. | Each | 260.78 | 260.78 | 8.0 | False | None | None | False | None | False | 2086.24 | 0 | 3659714 | 133529 | None | Bescom SR 2023 24 6 09 | Supplying and fixing of DISC Insulator 45 kN Porcelain etc, complete ,as per the directions of Engineer in charge of the work. | No | 601.8 | 601.8 | 7.0 | False | None | None | False | None | False | 4212.6 | 0 | 3659715 | 133529 | None | Page 45 11 9 3 Vol 6 | Supply of LED floodlight 120 W luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. | Each | 12693.26 | 12693.26 | 4.0 | False | None | None | False | None | False | 50773.04 | 0 | 3659716 | 133529 | None | Page 12 4 6 5 Vol 6 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Double Arm Bracket with 1500 mm Standard 40/50 mm dia | Each | 3894.0 | 3894.0 | 2.0 | False | None | None | False | None | False | 7788.0 | 0 | 3659717 | 133529 | None | Page 10 4 2 7 Vol 6 | Fabricating, supplying and erection of 9 m - Top 70 mm and Bottom 155 mm dia ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for .......m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top.... mm with 3 mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended. | Each | 23010.0 | 23010.0 | 1.0 | False | None | None | False | None | False | 23010.0 | 0 | 3659718 | 133529 | None | DGS and D Rates | Solar Street Light System With Mounting Structure & Pole ( MNES Specification) Description of item: 2 X 18 W LED ,PV Module: 120 W,Battery Capacity: 12 V ,100 AH | No | 40392.58 | 40392.58 | 6.0 | False | None | None | False | None | False | 242355.48 | 0 | 3659719 | 133529 | None | BWSSB Page 247 21 1 1 Vol 5 | Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge.For 25 LPH : Cabin Type | Each | 29500.0 | 29500.0 | 1.0 | False | None | None | False | None | False | 29500.0 | 0 |
|