tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1722491035000 | 0 | None | None | Buildings | CONSTRUCTION OF 3 BAY FIRE STATION AT ARAKERA IN RAICHUR DISTRICT UNDER K-SAFE SCHEME (CIVIL) | 23812050.62 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3662680 | 133688 | None | Vol-1,P-8,1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading,caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work | Cum | 117.71 | 117.71 | 3240.0 | False | None | None | False | None | False | 381380.4 | 0 | 3662681 | 133688 | None | Vol-1,P-8,1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m In all kinds of soils OS, HS 30 percent | Cum | 126.38 | 126.38 | 84.2 | False | None | None | False | None | False | 10641.196 | 0 | 3662682 | 133688 | None | Vol-1,P-8,1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m In soft rock without blasting 70 percent | Cum | 449.76 | 449.76 | 196.48 | False | None | None | False | None | False | 88368.8448 | 0 | 3662683 | 133688 | None | Vol-1,P-58,2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm and down size graded crushed coarse aggregates | Cum | 7017.7 | 7017.7 | 115.88 | False | None | None | False | None | False | 813211.076 | 0 | 3662684 | 133688 | None | Vol-1,P-15,2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Column footing | Cum | 8412.76 | 8412.76 | 45.21 | False | None | None | False | None | False | 380340.8796 | 0 | 3662685 | 133688 | None | Vol-2,P-9,5.3 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 7688.0 | 7688.0 | 101.24 | False | None | None | False | None | False | 778333.12 | 0 | 3662686 | 133688 | None | Vol-2,P-9,5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 7915.97 | 7915.97 | 42.33 | False | None | None | False | None | False | 335083.0101 | 0 | 3662687 | 133688 | None | Vol-1,P-16,2.5.1 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Column Ground Floor. | Cum | 13964.77 | 13964.77 | 23.0 | False | None | None | False | None | False | 321189.71 | 0 | 3662688 | 133688 | None | Vol-1,P-16,2.5.1 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Column First Floor. | Cum | 14046.91 | 14046.91 | 18.1 | False | None | None | False | None | False | 254249.071 | 0 | 3662689 | 133688 | None | Vol-1,P-16,2.4.2 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Plinth beam. | Cum | 11751.3 | 11751.3 | 23.07 | False | None | None | False | None | False | 271102.491 | 0 | 3662690 | 133688 | None | Vol-1,P-7,1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
a.With available earth (30 percent of excavated earth) | Cum | 329.57 | 329.57 | 84.2 | False | None | None | False | None | False | 27749.794 | 0 | 3662691 | 133688 | None | Vol-1,P-7,1.8 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. with new earth | Cum | 587.29 | 587.29 | 394.82 | False | None | None | False | None | False | 231873.8378 | 0 | 3662692 | 133688 | None | Vol-2,P-14,6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work Ground Floor. | Cum | 9873.59 | 9873.59 | 73.14 | False | None | None | False | None | False | 722154.3726 | 0 | 3662693 | 133688 | None | Vol-2,P-14,6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work First Floor. | Cum | 9972.33 | 9972.33 | 66.72 | False | None | None | False | None | False | 665353.8576 | 0 | 3662694 | 133688 | None | Vol-2,P-14,6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work Third Floor. | Cum | 10071.06 | 10071.06 | 23.95 | False | None | None | False | None | False | 241201.887 | 0 | 3662695 | 133688 | None | Vol-2,P-14,6.15 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work Ground Floor. | Sqm | 1279.89 | 1279.89 | 27.53 | False | None | None | False | None | False | 35235.3717 | 0 | 3662696 | 133688 | None | Vol-2,P-14,6.15 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work First Floor. | Sqm | 1292.69 | 1292.69 | 30.34 | False | None | None | False | None | False | 39220.2146 | 0 | 3662697 | 133688 | None | Vol-1,P-15,2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates For coping & window cills Ground Floor. | Cum | 8088.01 | 8088.01 | 4.82 | False | None | None | False | None | False | 38984.2082 | 0 | 3662698 | 133688 | None | Vol-1,P-15,2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates For coping & window cills First Floor. | Cum | 8165.03 | 8165.03 | 1.88 | False | None | None | False | None | False | 15350.2564 | 0 | 3662699 | 133688 | None | Vol-1,P-15,2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates For coping & window cills Third Floor. | Cum | 8242.06 | 8242.06 | 1.14 | False | None | None | False | None | False | 9395.9484 | 0 | 3662700 | 133688 | None | Vol-1,P-16,2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Staircase/lintel/Wall Shelves/Roof beam/Roofslab
Ground Floor
A Staircase/lintel/Wall Shelves | Cum | 12321.86 | 12321.86 | 40.45 | False | None | None | False | None | False | 498419.237 | 0 | 3662701 | 133688 | None | Vol-1,P-16,2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Staircase/lintel/Wall Shelves/Roof beam/Roofslab Ground Floor
B Lintels and Roof beams | Cum | 13143.31 | 13143.31 | 21.95 | False | None | None | False | None | False | 288495.6545 | 0 | 3662702 | 133688 | None | Vol-1,P-16,2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Staircase/lintel/Wall Shelves/Roof beam/Roofslab First Floor
A taircase/lintel/Wall Shelves | Cum | 12404.0 | 12404.0 | 76.5 | False | None | None | False | None | False | 948906.0 | 0 | 3662703 | 133688 | None | Vol-1,P-16,2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Staircase/lintel/Wall Shelves/Roof beam/Roofslab First Floor
B Lintels and Roof beams | Cum | 13225.46 | 13225.46 | 22.96 | False | None | None | False | None | False | 303656.5616 | 0 | 3662704 | 133688 | None | Vol-1,P-16,2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Plain Chejja Ground Floor | Cum | 11911.13 | 11911.13 | 0.75 | False | None | None | False | None | False | 8933.3475 | 0 | 3662705 | 133688 | None | Vol-1,P-16,2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Plain Chejja First Floor | Cum | 11993.27 | 11993.27 | 0.7 | False | None | None | False | None | False | 8395.289 | 0 | 3662706 | 133688 | None | Vol-1,P-18,2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Ground Floor | Tonne | 110837.22 | 110837.22 | 28.07 | False | None | None | False | None | False | 3111200.7654 | 0 | 3662707 | 133688 | None | Vol-1,P-18,2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification First Floor | Tonne | 111945.6 | 111945.6 | 11.85 | False | None | None | False | None | False | 1326555.36 | 0 | 3662708 | 133688 | None | Vol-2,P-44,8.19.1 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. | Sqm | 315.95 | 315.95 | 27.82 | False | None | None | False | None | False | 8789.729 | 0 | 3662709 | 133688 | None | Vol-2,P-42,8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For External walls Ground Floor | Sqm | 477.02 | 477.02 | 308.3 | False | None | None | False | None | False | 147065.266 | 0 | 3662710 | 133688 | None | Vol-2,P-42,8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For External walls First Floor | Sqm | 481.79 | 481.79 | 323.54 | False | None | None | False | None | False | 155878.3366 | 0 | 3662711 | 133688 | None | Vol-2,P-42,8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For External walls Third Floor | Sqm | 486.56 | 486.56 | 101.3 | False | None | None | False | None | False | 49288.528 | 0 | 3662712 | 133688 | None | Vol-2,P-41,8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Common SR 2023-24 Vol-2 P.No. 41, I.No. 8.4.2 For Ceiling Ground Floor | Sqm | 394.3 | 394.3 | 415.68 | False | None | None | False | None | False | 163902.624 | 0 | 3662713 | 133688 | None | Vol-2,P-41,8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Common SR 2023-24 Vol-2 P.No. 41, I.No. 8.4.2 For Ceiling First Floor | Sqm | 390.43 | 390.43 | 229.71 | False | None | None | False | None | False | 89685.6753 | 0 | 3662714 | 133688 | None | Vol-2,P-41,8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Common SR 2023-24 Vol-2 P.No. 41, I.No. 8.4.2 For Ceiling Third Floor | Sqm | 394.3 | 394.3 | 23.72 | False | None | None | False | None | False | 9352.796 | 0 | 3662715 | 133688 | None | Vol-2,P-41,8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Inside walls Ground Floor. | Sqm | 298.6 | 298.6 | 615.85 | False | None | None | False | None | False | 183892.81 | 0 | 3662716 | 133688 | None | Vol-2,P-41,8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Inside walls First Floor. | Sqm | 301.58 | 301.58 | 399.98 | False | None | None | False | None | False | 120625.9684 | 0 | 3662717 | 133688 | None | Vol-2,P-41,8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Inside walls Third Floor. | Sqm | 304.57 | 304.57 | 56.58 | False | None | None | False | None | False | 17232.5706 | 0 | 3662718 | 133688 | None | Vol-2,P-50,8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge Ground Floor | Sqm | 123.9 | 123.9 | 1078.6 | False | None | None | False | None | False | 133638.54 | 0 | 3662719 | 133688 | None | Vol-2,P-50,8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge First Floor | Sqm | 123.9 | 123.9 | 716.52 | False | None | None | False | None | False | 88776.828 | 0 | 3662720 | 133688 | None | Vol-2,P-50,8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge Third Floor | Sqm | 123.9 | 123.9 | 80.3 | False | None | None | False | None | False | 9949.17 | 0 | 3662721 | 133688 | None | Vol-2,P-41,8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge Ground Floor. | Sqm | 345.68 | 345.68 | 52.71 | False | None | None | False | None | False | 18220.7928 | 0 | 3662722 | 133688 | None | Vol-2,P-41,8.2.2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge First Floor. | Sqm | 349.14 | 349.14 | 61.74 | False | None | None | False | None | False | 21555.9036 | 0 | 3662723 | 133688 | None | Vol-2,P-44,8.16a | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20cms, c to c both horizontally and vertically fixed with chicken mesh for dropchajja.facia, backing to cup boards including cost of all materials,labour,providing and removing form work usage charges, curing, complete as per specifications Ground Floor | Sqm | 1533.88 | 1533.88 | 16.92 | False | None | None | False | None | False | 25953.2496 | 0 | 3662724 | 133688 | None | Vol-2,P-44,8.16a | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20cms, c to c both horizontally and vertically fixed with chicken mesh for dropchajja.facia, backing to cup boards including cost of all materials,labour,providing and removing form work usage charges, curing, complete as per specifications First Floor | Sqm | 1533.88 | 1533.88 | 43.22 | False | None | None | False | None | False | 66294.2936 | 0 | 3662725 | 133688 | None | Vol-2,P-63,9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent Ground Floor. | Sqm | 3533.63 | 3533.63 | 171.6 | False | None | None | False | None | False | 606370.908 | 0 | 3662726 | 133688 | None | Vol-2,P-63,9.24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, Lakared, River Pink, Orissa Blue or equivalent First Floor. | Sqm | 3568.96 | 3568.96 | 68.1 | False | None | None | False | None | False | 243046.176 | 0 | 3662727 | 133688 | None | Vol-2,P-62,9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm Ground Floor | Sqm | 1642.91 | 1642.91 | 102.57 | False | None | None | False | None | False | 168513.2787 | 0 | 3662728 | 133688 | None | Vol-2,P-62,9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm First Floor | Sqm | 1659.34 | 1659.34 | 109.31 | False | None | None | False | None | False | 181382.4554 | 0 | 3662729 | 133688 | None | Vol-2,P-60,9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Ground Floor. | Sqm | 1101.47 | 1101.47 | 27.63 | False | None | None | False | None | False | 30433.6161 | 0 | 3662730 | 133688 | None | Vol-2,P-60,9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete First Floor. | Sqm | 1112.49 | 1112.49 | 18.03 | False | None | None | False | None | False | 20058.1947 | 0 | 3662731 | 133688 | None | Vol-2,P-65,9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications Ground Floor. | Sqm | 1795.31 | 1795.31 | 52.71 | False | None | None | False | None | False | 94630.7901 | 0 | 3662732 | 133688 | None | Vol-2,P-65,9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications First Floor. | Sqm | 1813.26 | 1813.26 | 61.74 | False | None | None | False | None | False | 111950.6724 | 0 | 3662733 | 133688 | None | Vol-1,P-11,1.23 | Providing and Filling in foundation with granite/trap broken metal 100mm and downsize & with approved sand including hand packing. ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. | Cum | 3323.0 | 3323.0 | 54.71 | False | None | None | False | None | False | 181801.33 | 0 | 3662734 | 133688 | None | Vol-2,P-59,9.2 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge | Sqm | 991.2 | 991.2 | 221.61 | False | None | None | False | None | False | 219659.832 | 0 | 3662735 | 133688 | None | Vol-2,P-100,12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications Ground Floor. | Cum | 122431.79 | 122431.79 | 0.32 | False | None | None | False | None | False | 39178.1728 | 0 | 3662736 | 133688 | None | Vol-2,P-100,12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications First Floor. | Cum | 122431.79 | 122431.79 | 0.27 | False | None | None | False | None | False | 33056.5833 | 0 | 3662737 | 133688 | None | Vol-2,P-104,12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications Ground Floor. | Nos | 1258.82 | 1258.82 | 7.0 | False | None | None | False | None | False | 8811.74 | 0 | 3662738 | 133688 | None | Vol-2,P-104,12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications First Floor. | Nos | 1258.82 | 1258.82 | 6.0 | False | None | None | False | None | False | 7552.92 | 0 | 3662739 | 133688 | None | Vol-2,P-105,12.57.4 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification. 35 mm thick both side Teak Ground Floor | Sqm | 5615.15 | 5615.15 | 4.92 | False | None | None | False | None | False | 27626.538 | 0 | 3662740 | 133688 | None | Vol-2,P-105,12.57.4 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification. 35 mm thick both side Teak First Floor | Sqm | 5671.3 | 5671.3 | 6.56 | False | None | None | False | None | False | 37203.728 | 0 | 3662741 | 133688 | None | Vol-2,P-105,12.57.1 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification. 30 mm thick both side Teak Ground Floor | Sqm | 5009.28 | 5009.28 | 9.02 | False | None | None | False | None | False | 45183.7056 | 0 | 3662742 | 133688 | None | Vol-2,P-105,12.57.1 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification. 30 mm thick both side Teak First Floor | Sqm | 5059.37 | 5059.37 | 4.41 | False | None | None | False | None | False | 22311.8217 | 0 | 3662743 | 133688 | None | Vol-2,P-104,12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge Ground Floor. | m | 394.0 | 394.0 | 20.4 | False | None | None | False | None | False | 8037.6 | 0 | 3662744 | 133688 | None | Vol-2,P-104,12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge First Floor. | m | 394.0 | 394.0 | 20.4 | False | None | None | False | None | False | 8037.6 | 0 | 3662745 | 133688 | None | Vol-2,P-104,12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with two side prelam Ground Floor | Sqm | 2931.47 | 2931.47 | 6.97 | False | None | None | False | None | False | 20432.3459 | 0 | 3662746 | 133688 | None | Vol-2,P-104,12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with two side prelam First Floor | Sqm | 2931.47 | 2931.47 | 6.97 | False | None | None | False | None | False | 20432.3459 | 0 | 3662747 | 133688 | None | Vol-2,P-111,12.89 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Ground Floor | Sqm | 8116.69 | 8116.69 | 19.85 | False | None | None | False | None | False | 161116.2965 | 0 | 3662748 | 133688 | None | Vol-2,P-111,12.89 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Fist Floor | Sqm | 8116.69 | 8116.69 | 19.25 | False | None | None | False | None | False | 156246.2825 | 0 | 3662749 | 133688 | None | Vol-2,P-86,11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Ground Floor | Kgs | 208.15 | 208.15 | 545.75 | False | None | None | False | None | False | 113597.8625 | 0 | 3662750 | 133688 | None | Vol-2,P-86,11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding First Floor | Kgs | 208.15 | 208.15 | 404.15 | False | None | None | False | None | False | 84123.8225 | 0 | 3662751 | 133688 | None | Vol-2,P-85,11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 700.04 | 700.04 | 811.76 | False | None | None | False | None | False | 568264.4704 | 0 | 3662752 | 133688 | None | Vol-2,P-184,18.7 | Design supply & installation of suspended Spider Glazing system designed to with stand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. | Sqm | 9852.53 | 9852.53 | 52.31 | False | None | None | False | None | False | 515385.8443 | 0 | 3662753 | 133688 | None | Vol-2,P-46,8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge Ground Floor. | Sqm | 215.59 | 215.59 | 309.28 | False | None | None | False | None | False | 66677.6752 | 0 | 3662754 | 133688 | None | Vol-2,P-46,8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge First Floor. | Sqm | 217.74 | 217.74 | 398.31 | False | None | None | False | None | False | 86728.0194 | 0 | 3662755 | 133688 | None | Vol-2,P-46,8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge Third Floor. | Sqm | 219.9 | 219.9 | 101.3 | False | None | None | False | None | False | 22275.87 | 0 | 3662756 | 133688 | None | Vol-2,P-50,8.54.2,P-51,8.55.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. For Ceiling & Inside walls Ground Floor | Sqm | 201.96 | 201.96 | 1068.71 | False | None | None | False | None | False | 215836.6716 | 0 | 3662757 | 133688 | None | Vol-2,P-50,8.54.2,P-51,8.55.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. For Ceiling & Inside walls First Floor | Sqm | 201.96 | 201.96 | 668.78 | False | None | None | False | None | False | 135066.8088 | 0 | 3662758 | 133688 | None | Vol-2,P-50,8.54.2,P-51,8.55.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. For Ceiling & Inside walls Third Floor | Sqm | 201.96 | 201.96 | 80.3 | False | None | None | False | None | False | 16217.388 | 0 | 3662759 | 133688 | None | Vol-2,P-48,8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge Ground Floor. | Sqm | 206.91 | 206.91 | 42.78 | False | None | None | False | None | False | 8851.6098 | 0 | 3662760 | 133688 | None | Vol-2,P-48,8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge First Floor . | Sqm | 208.98 | 208.98 | 39.09 | False | None | None | False | None | False | 8169.0282 | 0 | 3662761 | 133688 | None | Vol-2,P-41,8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Flagging | Sqm | 438.61 | 438.61 | 106.19 | False | None | None | False | None | False | 46575.9959 | 0 | 3662762 | 133688 | None | Vol-2,P-54,8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. | m | 64.43 | 64.43 | 840.94 | False | None | None | False | None | False | 54181.7642 | 0 | 3662763 | 133688 | None | Vol-2,P-55,8.84 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete | Each | 588.53 | 588.53 | 12.0 | False | None | None | False | None | False | 7062.36 | 0 | 3662764 | 133688 | None | Vol-3,P-63,8.3 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade | cm | 1.98 | 1.98 | 10000.0 | False | None | None | False | None | False | 19800.0 | 0 | 3662765 | 133688 | None | Vol-2,P-48,8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 142.49 | 142.49 | 10.6 | False | None | None | False | None | False | 1510.394 | 0 | 3662766 | 133688 | None | Vol-2,P-151,15.11 | Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface like Roof, bathroom, toilet, balcony & utility area applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break greater than 120% as per ASTM D 412, Tensile strength greater than1N/mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. | Sqm | 650.48 | 650.48 | 610.65 | False | None | None | False | None | False | 397215.612 | 0 | 3662767 | 133688 | None | Vol-2,P-5,4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 146.2 | 146.2 | 530.6 | False | None | None | False | None | False | 77573.72 | 0 | 3662768 | 133688 | None | Vol-2,P-69,10.2 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. | m | 406.39 | 406.39 | 105.36 | False | None | None | False | None | False | 42817.2504 | 0 | 3662769 | 133688 | None | Approved rate | Providing and fixing of Signage boards etc. complete with all lead, lifts, loading, unloading, scaffolding arrangement, cost and conveyance of all materials, labour, equipment, transportation charges, testing and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc,. complete and as per the directions of the Engineer in-charge of the work. | Each | 112100.0 | 112100.0 | 1.0 | False | None | None | False | None | False | 112100.0 | 0 | 3662770 | 133688 | None | Vol-2,P-106,12.68.1 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. 125x65x2.12mm | Nos | 68.15 | 68.15 | 48.0 | False | None | None | False | None | False | 3271.2 | 0 | 3662771 | 133688 | None | Vol-2,P-106,12.68.2 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. 100x58x1.9mm | Nos | 53.28 | 53.28 | 42.0 | False | None | None | False | None | False | 2237.76 | 0 | 3662772 | 133688 | None | Vol-2,P-108,12.72 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : | Nos | 101.6 | 101.6 | 60.0 | False | None | None | False | None | False | 6096.0 | 0 | 3662773 | 133688 | None | Vol-2,P-108,12.73.1 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125mm | Nos | 54.52 | 54.52 | 60.0 | False | None | None | False | None | False | 3271.2 | 0 | 3662774 | 133688 | None | Vol-2,P-107,12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Nos | 148.68 | 148.68 | 21.0 | False | None | None | False | None | False | 3122.28 | 0 | 3662775 | 133688 | None | Market Rate | Providing and fixing Aldrops for door shutters with necessary screws, etc. complete. | Nos | 295.0 | 295.0 | 30.0 | False | None | None | False | None | False | 8850.0 | 0 | 3662776 | 133688 | None | Vol-2,P-448,A-25 | Providing and fixing teak wood beading for door shutters 20x20 mm | m | 68.15 | 68.15 | 78.0 | False | None | None | False | None | False | 5315.7 | 0 | 3662777 | 133688 | None | Vol-2,P-62,9.20.2 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge Ground Floor. | Sqm | 258.95 | 258.95 | 96.22 | False | None | None | False | None | False | 24916.169 | 0 | 3662778 | 133688 | None | Vol-2,P-62,9.20.2 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge First Floor. | Sqm | 261.54 | 261.54 | 101.8 | False | None | None | False | None | False | 26624.772 | 0 | 3662779 | 133688 | None | SR 2018-19 P-149,19.88 | KSRRB M300-9. Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1m deep dug in the ground, mixing the soil with decayed farm yard / sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintenance the plants for one year complete as per specifications.MORTH Specification No.307. SR 2018-19 P.No.149 I.No.19.88 | Nos | 1239.0 | 1239.0 | 10.0 | False | None | None | False | None | False | 12390.0 | 0 | 3662780 | 133688 | None | Vol-1,P-6,1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. in all types of soils | Cum | 599.68 | 599.68 | 32.0 | False | None | None | False | None | False | 19189.76 | 0 | 3662781 | 133688 | None | Vol-1,P-7,1.10 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 198.24 | 198.24 | 31.05 | False | None | None | False | None | False | 6155.352 | 0 | 3662782 | 133688 | None | Vol-2,P-122,13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride(CPVC)pipes, having thermal stability for hot & cold watersupply,including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
CPVC pipe - 25mm (Internal) | m | 591.0 | 591.0 | 50.0 | False | None | None | False | None | False | 29550.0 | 0 | 3662783 | 133688 | None | Vol-2,P-122,13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride(CPVC)pipes, having thermal stability for hot & cold watersupply,including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
CPVC pipe - 32mm (External) | m | 690.12 | 690.12 | 90.0 | False | None | None | False | None | False | 62110.8 | 0 | 3662784 | 133688 | None | Vol-5,P-113,10.1.5 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation 75 mm | m | 272.58 | 272.58 | 400.0 | False | None | None | False | None | False | 109032.0 | 0 | 3662785 | 133688 | None | Vol-5,P-113,10.1.6 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation 90 mm | m | 364.27 | 364.27 | 90.0 | False | None | None | False | None | False | 32784.3 | 0 | 3662786 | 133688 | None | Vol-5,P-113,10.1.7 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation 110 mm | m | 509.23 | 509.23 | 150.0 | False | None | None | False | None | False | 76384.5 | 0 | 3662787 | 133688 | None | Vol-5,P-113,10.1.9 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation 160 mm | m | 765.7 | 765.7 | 90.0 | False | None | None | False | None | False | 68913.0 | 0 | 3662788 | 133688 | None | approved rate gruha-2025 | Providing and fixing in position Pillar cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. FS | Each | 1475.0 | 1475.0 | 6.0 | False | None | None | False | None | False | 8850.0 | 0 | 3662789 | 133688 | None | approved rate gruha-2025 | Providing and fixing in position Short body cock/tap of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. FS | Each | 1475.0 | 1475.0 | 6.0 | False | None | None | False | None | False | 8850.0 | 0 | 3662790 | 133688 | None | approved rate gruha-2025 | Providing and fixing in position Long body cock/tap of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work.FS | Each | 1593.0 | 1593.0 | 4.0 | False | None | None | False | None | False | 6372.0 | 0 | 3662791 | 133688 | None | approved rate gruha-2025 | Providing and fixing in position Angle stop cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work.FS | Each | 1475.0 | 1475.0 | 6.0 | False | None | None | False | None | False | 8850.0 | 0 | 3662792 | 133688 | None | approved rate gruha-2025 | Providing and fixing in position Two way bib cock of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. FS | Each | 1593.0 | 1593.0 | 2.0 | False | None | None | False | None | False | 3186.0 | 0 | 3662793 | 133688 | None | approved rate gruha-2025 | Providing and fixing in position Health faucet complete set of Jaquar/Hindware/Parry ware of approved quality 20mm nominal bore including cost and conveyance of all materials, cost of labour,HOM of machinery and equipments with all lead, lifts, loading and unloading and all other incidental charges required for successful completion of work as per approved specification, designs, drawings etc., complete and directions of the Engineer in-charge of the work. FS | Each | 1593.0 | 1593.0 | 2.0 | False | None | None | False | None | False | 3186.0 | 0 | 3662794 | 133688 | None | Vol-2,P-124,13.46 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors:
*100mminletand75mmoutlet ,
* Hubless centrifugally cast(spun) iron epoxy coated inside & outside as per IS:15905 10cmx10cm | Each | 588.53 | 588.53 | 8.0 | False | None | None | False | None | False | 4708.24 | 0 | 3662795 | 133688 | None | Vol-2,P-123,13.34 | Providing and placing on terrace (at all floor levels ) polyethylene water storagetank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittinigs and the base support for tank.1000Ltr | l | 11.15 | 11.15 | 1000.0 | False | None | None | False | None | False | 11150.0 | 0 | 3662796 | 133688 | None | Vol-5,P-191,16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover | Each | 6757.51 | 6757.51 | 5.0 | False | None | None | False | None | False | 33787.55 | 0 | 3662797 | 133688 | None | Vol-5,P-191,16.10 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover | Each | 5248.4 | 5248.4 | 10.0 | False | None | None | False | None | False | 52484.0 | 0 | 3662798 | 133688 | None | Vol-2,P-117,13.4.1 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25mm dia | Each | 680.21 | 680.21 | 1.0 | False | None | None | False | None | False | 680.21 | 0 | 3662799 | 133688 | None | Vol-2,P-117,13.4.2 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm dia | Each | 740.92 | 740.92 | 1.0 | False | None | None | False | None | False | 740.92 | 0 | 3662800 | 133688 | None | Vol-2,P-117,13.4.4 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :50 mm dia | Each | 1059.35 | 1059.35 | 2.0 | False | None | None | False | None | False | 2118.7 | 0 | 3662801 | 133688 | None | Vol-2,P-131,14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 7405.5 | 7405.5 | 2.0 | False | None | None | False | None | False | 14811.0 | 0 | 3662802 | 133688 | None | Vol-2,P-131,14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests | Each | 6051.28 | 6051.28 | 4.0 | False | None | None | False | None | False | 24205.12 | 0 | 3662803 | 133688 | None | Vol-2,P-132,14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15mm C.P. brass pillar tap | Each | 3173.08 | 3173.08 | 8.0 | False | None | None | False | None | False | 25384.64 | 0 | 3662804 | 133688 | None | 2018-19,P-269,37.35 | Wall bores in Brick masonry upto 45 em thick. including cost of materials, labour, HOM complete as per specifications. | Each | 148.68 | 148.68 | 25.0 | False | None | None | False | None | False | 3717.0 | 0 | 3662805 | 133688 | None | 2018-19,P-269,37.36.1 | Wall bores in size stone masonry. including cost of materials, labour, HOM
complete as per specifications. upto 45 em thick. | Each | 357.54 | 357.54 | 10.0 | False | None | None | False | None | False | 3575.4 | 0 | 3662806 | 133688 | None | Vol-2,P-70,10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. | Sqm | 3455.57 | 3455.57 | 7.5 | False | None | None | False | None | False | 25916.775 | 0 | 3662807 | 133688 | None | Vol-2,P-136,14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm | Each | 1261.3 | 1261.3 | 8.0 | False | None | None | False | None | False | 10090.4 | 0 | 3662808 | 133688 | None | Vol-2,P-137,14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 614.54 | 614.54 | 8.0 | False | None | None | False | None | False | 4916.32 | 0 | 3662809 | 133688 | None | 2018-19,P-18,34 | Providing 10cms dia PVC cowl with cap of approved 1 st quality and make conforming to ISI specifications and fixing in position as directed (Rate includes cost of materials fixtures including conveyance charges to the work spot) | Nos | 270.22 | 270.22 | 2.0 | False | None | None | False | None | False | 540.44 | 0 | 3662810 | 133688 | None | 2018-19,P-90,12.111 | Providing and fixing 7.5 cms to 15.00 cms dia NP grating 100 mm dia | Each | 177.0 | 177.0 | 8.0 | False | None | None | False | None | False | 1416.0 | 0 | 3662811 | 133688 | None | Vol-5,P-127,8.79 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. Light Duty GI pipe of 50mm dia (sump to firebay load and flag post) | m | 547.64 | 547.64 | 35.0 | False | None | None | False | None | False | 19167.4 | 0 | 3662812 | 133688 | None | Vol-2,P-135,14.23 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. | Each | 1429.81 | 1429.81 | 6.0 | False | None | None | False | None | False | 8578.86 | 0 | 3662813 | 133688 | None | Vol-2,P-153,17.14 | Providing and laying 100mm thick pre-cast cover slabs over Road side drains / utility ducts / Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 550 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete | Sqm | 1449.63 | 1449.63 | 15.0 | False | None | None | False | None | False | 21744.45 | 0 | 3662814 | 133688 | None | Vol-1,P-8,1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m in all kinds of soil OS HS 30 percent | Cum | 126.38 | 126.38 | 44.96 | False | None | None | False | None | False | 5682.0448 | 0 | 3662815 | 133688 | None | Vol-1,P-8,1.15.2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m in ordinary/soft rock without blasting 70 percent | Cum | 449.76 | 449.76 | 104.9 | False | None | None | False | None | False | 47179.824 | 0 | 3662816 | 133688 | None | Vol-1,P-15,2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm and down size graded crushed coarse aggregates | Cum | 7017.7 | 7017.7 | 11.87 | False | None | None | False | None | False | 83300.099 | 0 | 3662817 | 133688 | None | Vol-1,P-7,1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 43.8 | False | None | None | False | None | False | 14435.166 | 0 | 3662818 | 133688 | None | Vol-1,P-15,2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For bottom slab & side RCC Walls | Cum | 8568.55 | 8568.55 | 32.7 | False | None | None | False | None | False | 280191.585 | 0 | 3662819 | 133688 | None | Vol-1,P-15,2.2.1 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Roofslab | Cum | 11684.39 | 11684.39 | 5.62 | False | None | None | False | None | False | 65666.2718 | 0 | 3662820 | 133688 | None | Vol-1,P-18,2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification | Tonne | 110837.22 | 110837.22 | 3.27 | False | None | None | False | None | False | 362437.7094 | 0 | 3662821 | 133688 | None | Vol-2,P-42,8.6.2 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 531.53 | 531.53 | 162.2 | False | None | None | False | None | False | 86214.166 | 0 | 3662822 | 133688 | None | Vol-5,P-85,7.3 | Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. | Each | 2651.46 | 2651.46 | 1.0 | False | None | None | False | None | False | 2651.46 | 0 | 3662823 | 133688 | None | Vol-5,P-85,7.1.2 | Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with: MS angle of 65 x 65 x 10mm | m | 5948.44 | 5948.44 | 4.5 | False | None | None | False | None | False | 26767.98 | 0 | 3662824 | 133688 | None | Vol-1,P-5,1.4.1 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. n all kinds of soils Depth upto 1.5 m
In all kinds of soils OS/HS (30%) | Cum | 299.84 | 299.84 | 17.49 | False | None | None | False | None | False | 5244.2016 | 0 | 3662825 | 133688 | None | Vol-1,P-6,1.5.4 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. n all kinds of soils Depth upto 1.5 m
In ordinary/soft rock without blasting (70%) | Cum | 370.46 | 370.46 | 40.81 | False | None | None | False | None | False | 15118.4726 | 0 | 3662826 | 133688 | None | Vol-1,P-58,2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm and down size graded crushed coarse aggregates | Cum | 7017.7 | 7017.7 | 3.3 | False | None | None | False | None | False | 23158.41 | 0 | 3662827 | 133688 | None | Vol-1,P-7,1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 329.57 | 329.57 | 14.25 | False | None | None | False | None | False | 4696.3725 | 0 | 3662828 | 133688 | None | Vol-1,P-15,2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For bottom slab & side RCC Walls
bottom slab & side RCC Walls | Cum | 8568.55 | 8568.55 | 9.77 | False | None | None | False | None | False | 83714.7335 | 0 | 3662829 | 133688 | None | Vol-1,P-15,2.2.1 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates For Roofslab | Cum | 11684.39 | 11684.39 | 2.24 | False | None | None | False | None | False | 26173.0336 | 0 | 3662830 | 133688 | None | Vol-1,P-18,2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification
RCC walls & Roofslab | Tonne | 110837.22 | 110837.22 | 0.98 | False | None | None | False | None | False | 108620.4756 | 0 | 3662831 | 133688 | None | Vol-2,P-42,8.6.2 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
bottomslab,side walls,top slab | Sqm | 531.53 | 531.53 | 67.78 | False | None | None | False | None | False | 36027.1034 | 0 | 3662832 | 133688 | None | Vol-1,P-5,1.4.1 | Earth work excavation by manual means for drains,canals and similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m A) In all kinds of soils OS HS (30 percent) | Cum | 299.84 | 299.84 | 3.82 | False | None | None | False | None | False | 1145.3888 | 0 | 3662833 | 133688 | None | Vol-1,P-6,1.5.1 | Earth work excavation by manual means for drains,canals and similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m b) In ordinary or soft rock without blasting (70 percent) | Cum | 370.46 | 370.46 | 8.91 | False | None | None | False | None | False | 3300.7986 | 0 | 3662834 | 133688 | None | SR 18-19,P-25,5.1 | KSRB 5-1.1 : Providing and constructing granite I trap I basalt rubble stone masonry in foundation with mud mortar (uncoursed), bond stones at 2m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.12 | Cum | 2874.48 | 2874.48 | 4.68 | False | None | None | False | None | False | 13452.5664 | 0 | 3662835 | 133688 | None | Vol-1,P-11,1.23 | Providing and Filling in foundation with granite/trap broken metal 100mm and downsize & with approved sand including hand packing. ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. | Cum | 3323.0 | 3323.0 | 4.58 | False | None | None | False | None | False | 15219.34 | 0 | 3662836 | 133688 | None | Vol-2,P-153,17.14 | Providing and laying 100mm thick pre-cast cover slabs over Road side drains / utility ducts / Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 550 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete | Sqm | 1449.63 | 1449.63 | 5.15 | False | None | None | False | None | False | 7465.5945 | 0 | 3662837 | 133688 | None | Vol-1,P-7,1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 536.49 | 536.49 | 3.12 | False | None | None | False | None | False | 1673.8488 | 0 | 3662838 | 133688 | None | Vol-1,P-5,1.4.1 | Earth work excavation by manual means for drains,canals and similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m a) In all kinds of soils OS or HS (70percent) | Cum | 299.84 | 299.84 | 45.64 | False | None | None | False | None | False | 13684.6976 | 0 | 3662839 | 133688 | None | Vol-1,P-6,1.5.1 | Earth work excavation by manual means for drains,canals and similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m b) In ordinary/soft rock without blasting (30 percent) | Cum | 370.46 | 370.46 | 19.56 | False | None | None | False | None | False | 7246.1976 | 0 | 3662840 | 133688 | None | Vol-1,P-7,1.10 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 198.24 | 198.24 | 63.48 | False | None | None | False | None | False | 12584.2752 | 0 | 3662841 | 133688 | None | Vol-5,P-113,10.1.7 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.(PVC pipe of 6Kgs/Sqm ) | m | 509.23 | 509.23 | 120.0 | False | None | None | False | None | False | 61107.6 | 0 | 3662842 | 133688 | None | Vol-5,P-191,16.10 | onstructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover | Each | 5248.4 | 5248.4 | 6.0 | False | None | None | False | None | False | 31490.4 | 0 | 3662843 | 133688 | None | Vol-1,P-7,1.11 | KSRB 5-1.1 : Providing and constructing granite I trap I basalt rubble stone masonry in foundation with mud mortar (uncoursed), bond stones at 2m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.12 | Cum | 2874.48 | 2874.48 | 7.25 | False | None | None | False | None | False | 20839.98 | 0 | 3662844 | 133688 | None | Vol-1,P-11,1.23 | Providing and Filling in foundation with granite/trap broken metal 100mm and downsize & with approved sand including hand packing. ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. | Cum | 3323.0 | 3323.0 | 6.97 | False | None | None | False | None | False | 23161.31 | 0 | 3662845 | 133688 | None | Vol-2,P-153,17.14 | Providing and laying 100mm thick pre-cast cover slabs over Road side drains / utility ducts / Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 550 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete | Sqm | 1449.63 | 1449.63 | 12.0 | False | None | None | False | None | False | 17395.56 | 0 | 3662846 | 133688 | None | Vol-5,P-140,12.40 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or | Nos | 6551.83 | 6551.83 | 1.0 | False | None | None | False | None | False | 6551.83 | 0 | 3662847 | 133688 | None | Vol-5,P-139,12.2.1 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for:i) Up to 0.00 to 50.00 mtrs | m | 382.85 | 382.85 | 50.0 | False | None | None | False | None | False | 19142.5 | 0 | 3662848 | 133688 | None | Vol-5,P-139,12.2.2 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for:ii) Up to 50.00 to 100.00 mtrs | m | 479.49 | 479.49 | 50.0 | False | None | None | False | None | False | 23974.5 | 0 | 3662849 | 133688 | None | Vol-5,P-139,12.2.3 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for:iii) Up to 100.00 to 150.00 mtrs | m | 510.47 | 510.47 | 50.0 | False | None | None | False | None | False | 25523.5 | 0 | 3662850 | 133688 | None | Vol-5,P-143,12.32 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | m | 2394.99 | 2394.99 | 20.0 | False | None | None | False | None | False | 47899.8 | 0 | 3662851 | 133688 | None | Vol-5,P-127,11.1.6 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Medium Duty GI pipe: 50mm dia | m | 723.58 | 723.58 | 130.0 | False | None | None | False | None | False | 94065.4 | 0 | 3662852 | 133688 | None | Vol-2,P-118,13.6.4.1 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 50 mm nominal bore Horizontal | Nos | 1345.55 | 1345.55 | 2.0 | False | None | None | False | None | False | 2691.1 | 0 | 3662853 | 133688 | None | Vol-5,P-143,12.33 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Each | 185.85 | 185.85 | 6.0 | False | None | None | False | None | False | 1115.1 | 0 | 3662854 | 133688 | None | Vol-5,P-143,12.34 | Providing and laying at site of work MS casing caps as per IS 1239 (partII) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Each | 203.2 | 203.2 | 1.0 | False | None | None | False | None | False | 203.2 | 0 | 3662855 | 133688 | None | Vol-1,P-8,1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work | Cum | 126.38 | 126.38 | 286.1 | False | None | None | False | None | False | 36157.318 | 0 | 3662856 | 133688 | None | Vol-1,P-58,2.1.2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7017.7 | 7017.7 | 5.25 | False | None | None | False | None | False | 36842.925 | 0 | 3662857 | 133688 | None | Vol-1,P-15,2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.For RCC head walls to the CD work. | Cum | 8568.55 | 8568.55 | 26.71 | False | None | None | False | None | False | 228865.9705 | 0 | 3662858 | 133688 | None | Vol-2,P-42,8.6.2 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Concrete surface | Sqm | 531.53 | 531.53 | 58.8 | False | None | None | False | None | False | 31253.964 | 0 | 3662859 | 133688 | None | Vol-1,P-18,2.11.a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification | Tonne | 110837.22 | 110837.22 | 4.01 | False | None | None | False | None | False | 444457.2522 | 0 | 3662860 | 133688 | None | Vol-3,P-18,3.11 | Preparation and surface treatment of formation by removing mud and slurry, watering to the extent needed to maintain the desired moisture content, trimming to the required line, grade, profile and rolling with 8-10 t smooth wheeled roller, complete as per clause 310. | Sqm | 4.96 | 4.96 | 880.0 | False | None | None | False | None | False | 4364.8 | 0 | 3662861 | 133688 | None | Vol-3,P-23,4.1(v) | Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -V Material | Cum | 3081.39 | 3081.39 | 132.0 | False | None | None | False | None | False | 406743.48 | 0 | 3662862 | 133688 | None | Vol-3,P-26,4.17 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. | Cum | 3170.6 | 3170.6 | 88.0 | False | None | None | False | None | False | 279012.8 | 0 | 3662863 | 133688 | None | Vol-3,P-149,16.28 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. | Cum | 8368.21 | 8368.21 | 154.0 | False | None | None | False | None | False | 1288704.34 | 0 |
| 1722491035000 | 0 | None | None | Buildings | CONSTRUCTION OF 3 BAY FIRE STATION AT ARAKERA IN RAICHUR DISTRICT UNDER K-SAFE SCHEME(ELECTRICAL) | 2359544.38 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3662864 | 133689 | None | Page-1-1.2.1-Vol-6 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia. mm thick confirming to IS 2509 with suitable size bends, metal-PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19-20 mm dia 2 mm thick as per direction of Engineer in charge. | m | 77.88 | 77.88 | 640.0 | False | None | None | False | None | False | 49843.2 | 0 | 3662865 | 133689 | None | Page-1-1.2.2-Vol-6 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia. mm thick confirming to IS 2509 with suitable size bends, metal-PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick as per direction of Engineer in charge. | m | 92.04 | 92.04 | 470.0 | False | None | None | False | None | False | 43258.8 | 0 | 3662866 | 133689 | None | Page-3-1.12-Vol-6 | Supplying And Fixing M.S. Rafter Clamp Set made out of M.S.
Flat & 14 mm M.S. rod.as per direction of Engineer in charge. | No | 188.8 | 188.8 | 9.0 | False | None | None | False | None | False | 1699.2 | 0 | 3662867 | 133689 | None | Page-3-1.13-Vol-6 | Supplying And Fixing Metal Fan Box with Round Hook.as per direction of Engineer in charge. | No | 138.06 | 138.06 | 10.0 | False | None | None | False | None | False | 1380.6 | 0 | 3662868 | 133689 | None | Page-1-1.3.1-Vol-6 | Supplying heavy gauge PVC Conduit Pipe .... dia mm thick
with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19-20 mm dia 2 mm thick as per direction of Engineer in charge. | m | 80.24 | 80.24 | 240.0 | False | None | None | False | None | False | 19257.6 | 0 | 3662869 | 133689 | None | Page-1-1.3.2-Vol-6 | Supplying heavy gauge PVC Conduit Pipe .... dia mm thick
with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick as per direction of Engineer in charge. | m | 93.22 | 93.22 | 360.0 | False | None | None | False | None | False | 33559.2 | 0 | 3662870 | 133689 | None | Page-17-5.19.8-Vol-6 | Supplying and fixing regular MCB distribution boards on wall-ood board - flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase-3 phase-single door with powder coated painting Made out of 14 SWG MS enclosure.-8 Way SP & N as per direction of Engineer in charge. | Each | 2187.72 | 2187.72 | 3.0 | False | None | None | False | None | False | 6563.16 | 0 | 3662871 | 133689 | None | Page-7-3.4.1-Vol-6 | Supplying and flush mounting powder coated - galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick-Stone-C.C
wall 1-2 Way as per direction of Engineer in charge. | Each | 162.84 | 162.84 | 28.0 | False | None | None | False | None | False | 4559.52 | 0 | 3662872 | 133689 | None | Page-7-3.4.3-Vol-6 | Supplying and flush mounting powder coated - galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick-Stone-C.C wall. Make - Group "A" materials and as per the directions of Engineer in charge of the work.4-5 Way as per direction of Engineer in charge. | Each | 208.86 | 208.86 | 8.0 | False | None | None | False | None | False | 1670.88 | 0 | 3662873 | 133689 | None | Page-7-3.4.4-Vol-6 | Supplying and flush mounting powder coated - galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick-Stone-C.C
wall 6 Way as per direction of Engineer in charge. | Each | 259.6 | 259.6 | 18.0 | False | None | None | False | None | False | 4672.8 | 0 | 3662874 | 133689 | None | Page-7-3.4.5-Vol-6 | Supplying and flush mounting powder coated - galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick-Stone-C.C
wall 8 Way as per direction of Engineer in charge. | Each | 307.98 | 307.98 | 10.0 | False | None | None | False | None | False | 3079.8 | 0 | 3662875 | 133689 | None | Page-7-3.4.6-Vol-6 | Supplying and flush mounting powder coated - galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick-Stone-C.C
wall 10-12 Way as per direction of Engineer in charge. | Each | 376.42 | 376.42 | 6.0 | False | None | None | False | None | False | 2258.52 | 0 | 3662876 | 133689 | None | Page-4-2.2.1-Vol-6 | Supplying and wiring adopting loop system in existing PVC Conduit
-casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet- gang box, the other end of the wires shall be terminated with sufficient loose length in a wood-PVC round block.complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box as per direction of Engineer in charge. | Point | 317.42 | 317.42 | 26.0 | False | None | None | False | None | False | 8252.92 | 0 | 3662877 | 133689 | None | Page-4-2.2.2-Vol-6 | Supplying and wiring adopting loop system in existing PVC Conduit
-casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet- gang box, the other end of the wires shall be terminated with sufficient loose length in a wood-PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box as per direction of Engineer in charge. | Point | 447.22 | 447.22 | 48.0 | False | None | None | False | None | False | 21466.56 | 0 | 3662878 | 133689 | None | Page-4-2.2.3-Vol-6 | Supplying and wiring adopting loop system in existing PVC Conduit
-casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet- gang box, the other end of the wires shall be terminated with sufficient loose length in a wood-PVC round block.complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box as per direction of Engineer in charge. | Point | 654.9 | 654.9 | 36.0 | False | None | None | False | None | False | 23576.4 | 0 | 3662879 | 133689 | None | Page-4-2.3.2-Vol-6 | Wiring for lighting-power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 1.5 sqmm as per direction of Engineer in charge. | m | 30.68 | 30.68 | 1280.0 | False | None | None | False | None | False | 39270.4 | 0 | 3662880 | 133689 | None | Page-4-2.3.3-Vol-6 | Wiring for lighting-power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 sqmm as per direction of Engineer in charge. | m | 49.56 | 49.56 | 2350.0 | False | None | None | False | None | False | 116466.0 | 0 | 3662881 | 133689 | None | Page-4-2.3.4-Vol-6 | Wiring for lighting-power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 sqmm as per direction of Engineer in charge. | m | 74.34 | 74.34 | 820.0 | False | None | None | False | None | False | 60958.8 | 0 | 3662882 | 133689 | None | Page-4-2.3.5-Vol-6 | Wiring for lighting-power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6 sqmm as per direction of Engineer in charge. | m | 108.56 | 108.56 | 300.0 | False | None | None | False | None | False | 32568.0 | 0 | 3662883 | 133689 | None | Page-7-3.5.1-Vol-6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal-PVC box. 1 to 2 Module as per direction of Engineer in charge. | Each | 161.66 | 161.66 | 28.0 | False | None | None | False | None | False | 4526.48 | 0 | 3662884 | 133689 | None | Page-7-3.5.3-Vol-6 | Supplying and fixing superior quality mod ular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal-PVC box.4 Module as per direction of Engineer in charge. | Each | 206.5 | 206.5 | 8.0 | False | None | None | False | None | False | 1652.0 | 0 | 3662885 | 133689 | None | Page-7-3.5.4-Vol-6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal-PVC box. 6 Module as per direction of Engineer in charge. | Each | 276.12 | 276.12 | 18.0 | False | None | None | False | None | False | 4970.16 | 0 | 3662886 | 133689 | None | Page-7-3.5.5-Vol-6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal-PVC box. 8 Module as per direction of Engineer in charge. | Each | 335.12 | 335.12 | 10.0 | False | None | None | False | None | False | 3351.2 | 0 | 3662887 | 133689 | None | Page-7-3.5.6-Vol-6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal-PVC box. 10-12 Module as per direction of Engineer in charge. | Each | 405.92 | 405.92 | 6.0 | False | None | None | False | None | False | 2435.52 | 0 | 3662888 | 133689 | None | Page-8-3.6.1-Vol-6 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch as per direction of Engineer in charge. | Each | 120.36 | 120.36 | 140.0 | False | None | None | False | None | False | 16850.4 | 0 | 3662889 | 133689 | None | Page-8-3.6.2-Vol-6 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 6A Two Way Switch as per direction of Engineer in charge. | Each | 195.88 | 195.88 | 8.0 | False | None | None | False | None | False | 1567.04 | 0 | 3662890 | 133689 | None | Page-8-3.6.3-Vol-6 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket as per direction of Engineer in charge. | Each | 201.78 | 201.78 | 44.0 | False | None | None | False | None | False | 8878.32 | 0 | 3662891 | 133689 | None | Page-8-3.6.4-Vol-6 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module as per direction of Engineer in charge. | Each | 421.26 | 421.26 | 12.0 | False | None | None | False | None | False | 5055.12 | 0 | 3662892 | 133689 | None | Page-8-3.6.9-Vol-6 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch as per direction of Engineer in charge. | Each | 384.68 | 384.68 | 4.0 | False | None | None | False | None | False | 1538.72 | 0 | 3662893 | 133689 | None | Page-8-3.6.10-Vol-6 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. 6-16A Universal Socket as per direction of Engineer in charge. | Each | 278.48 | 278.48 | 4.0 | False | None | None | False | None | False | 1113.92 | 0 | 3662894 | 133689 | None | Page-8-3.13.4-Vol-6 | Supplying and fixing of metal clad industrial plugs and sockets. 32 Amps ,3pole+earth 440V PLUG as per direction of Engineer in charge. | Each | 719.63 | 719.63 | 3.0 | False | None | None | False | None | False | 2158.89 | 0 | 3662895 | 133689 | None | Page-9-3.13.8-Vol-6 | Supplying and fixing of metal clad industrial plugs and sockets. 32 Amps ,3pole+earth 440V SOCKET as per direction of Engineer in charge. | Each | 976.83 | 976.83 | 3.0 | False | None | None | False | None | False | 2930.49 | 0 | 3662896 | 133689 | None | Page-51-12.46-Vol-6 | Supplying & Fixing of 70-150 W lamp holder 2 Pin as per direction of Engineer in charge. | No | 74.34 | 74.34 | 56.0 | False | None | None | False | None | False | 4163.04 | 0 | 3662897 | 133689 | None | Page-29-6.1-Vol-6 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with
bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.as per direction of Engineer in charge. | Each | 1760.56 | 1760.56 | 6.0 | False | None | None | False | None | False | 10563.36 | 0 | 3662898 | 133689 | None | Page-29-6.4.1-Vol-6 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374-19 and also comply with IS: 1709-1984 with latest amendment, Rated voltage 220 V-50 Hz, Rated power upto 35 W +-- 10 , Rated current As per IS:374-19, Rated power factor 0.9 lagging(min), Rated speed 350 +-- 10 RPM, Rated air delivery 210 +-- 10 Cubic Meter Minimum, Rated service value 6.2 CMM - W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374-2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans)-48" Sweep 5 Star (1200 mm) as per direction of Engineer in charge. | Each | 5077.54 | 5077.54 | 19.0 | False | None | None | False | None | False | 96473.26 | 0 | 3662899 | 133689 | None | Page-23-6.5.1-P-1 | Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply. 300 mm Sweep as per direction of Engineer in charge. | Each | 3124.64 | 3124.64 | 1.0 | False | None | None | False | None | False | 3124.64 | 0 | 3662900 | 133689 | None | Page-43-11.6.3-P-1 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast-extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI- 70 . efficacy - 100 lumen per W, 120degree beam spread, life- 25000 burning hours and Compliance to IS 10322-IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF - 0.95, power loss should- 5 of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 , Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL-CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition-LED modular down light 2'x2' 36 W as per direction of Engineer in charge. | No | 5372.54 | 5372.54 | 8.0 | False | None | None | False | None | False | 42980.32 | 0 | 3662901 | 133689 | None | Page-42-11.3.2-Vol-6 | Supplying of .....feet -PVC Batten with integrated LED tube 20-22 W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI - 80. Power Input: 220- 240V- 50-60Hz & Power factor -0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED light fitting 1 x 4' - 20-22 W as per direction of Engineer in charge. | Each | 814.2 | 814.2 | 36.0 | False | None | None | False | None | False | 29311.2 | 0 | 3662902 | 133689 | None | Page-46-11.11.7-Vol-6 | Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI- 70 . efficacy -80 lumen per W, life- 25000 burning hours and Compliance to IS 10322-IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF - 0.95, power loss should - 5 of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 , Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL-CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18W, 6500K as per direction of Engineer in charge. | Each | 502.68 | 502.68 | 20.0 | False | None | None | False | None | False | 10053.6 | 0 | 3662903 | 133689 | None | Page-55-13.7.1-Vol-6 | Fixing all types and all capacities of fluorescent -false ceiling - spot light - CFL - LED fittings indoor on the wall- ceiling - rafters - girders using 23-0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall- ceiling - Rafter - Girders as per direction of Engineer in charge. | Each | 143.96 | 143.96 | 44.0 | False | None | None | False | None | False | 6334.24 | 0 | 3662904 | 133689 | None | Page-56-13.10-Vol-6 | Fixing a ceiling - Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 - 0.0076 inch PVC insulated twin twisted copper wire and wiring.as per direction of Engineer in charge. | Each | 201.78 | 201.78 | 20.0 | False | None | None | False | None | False | 4035.6 | 0 | 3662905 | 133689 | None | Page-56-13.12-Vol-6 | Extra length of GI pipe of class B 19 mm dia for down rod.as per direction of Engineer in charge. | Mtr | 232.46 | 232.46 | 9.0 | False | None | None | False | None | False | 2092.14 | 0 | 3662906 | 133689 | None | Page-56-13.14-Vol-6 | Fixing one exhaust fan in the nitch already left in the wall with
bolts and nuts and 5 A. ceiling rose with sufficient length of 23-0.0076 inch PVC insulated twin core wire.as per direction of Engineer in charge. | Each | 580.56 | 580.56 | 6.0 | False | None | None | False | None | False | 3483.36 | 0 | 3662907 | 133689 | None | Page-47-12.2.3-Vol-6 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Remote Controled as per direction of Engineer in charge. | Each | 1404.2 | 1404.2 | 2.0 | False | None | None | False | None | False | 2808.4 | 0 | 3662908 | 133689 | None | Page-16-5.18.4-Vol-6 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON-OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6-32 A DP as per direction of Engineer in charge. | Each | 872.02 | 872.02 | 12.0 | False | None | None | False | None | False | 10464.24 | 0 | 3662909 | 133689 | None | Page-17-5.20.1-Vol-6 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240-450V upto 300mA sensitivity on existing wood- panel board.16A-25A 2 pole as per direction of Engineer in charge. | Each | 5046.86 | 5046.86 | 3.0 | False | None | None | False | None | False | 15140.58 | 0 | 3662910 | 133689 | None | Page-37-9.2.5-Vol-6 | Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A-C supply, with all accessories complete and Excluding batteries and wiring complete. 5 kVA OFF LINE UPS as per direction of Engineer in charge. | Each | 47079.64 | 47079.64 | 1.0 | False | None | None | False | None | False | 47079.64 | 0 | 3662911 | 133689 | None | Page-38-9.5.9-Vol-6 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 150 AH capacity as per direction of Engineer in charge. | Each | 18756.1 | 18756.1 | 8.0 | False | None | None | False | None | False | 150048.8 | 0 | 3662912 | 133689 | None | Page-8-3.6.11-Vol-6 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. TV-Telephone Socket as per direction of Engineer in charge. | Each | 184.08 | 184.08 | 3.0 | False | None | None | False | None | False | 552.24 | 0 | 3662913 | 133689 | None | Page-8-3.06.12-Vol-6 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. RJ45-I.O Outlet Cat-6 as per direction of Engineer in charge. | Each | 397.66 | 397.66 | 18.0 | False | None | None | False | None | False | 7157.88 | 0 | 3662914 | 133689 | None | Page-35-8.1-Vol-6 | Supplying and drawing UTP-CAT 6E LAN cable. | m | 44.84 | 44.84 | 650.0 | False | None | None | False | None | False | 29146.0 | 0 | 3662915 | 133689 | None | Page-35-8.2.2-Vol-6 | Supplying and drawing PVC flexible one pair telephone
unarmoured tinned copper cable.-2Pair as per direction of Engineer in charge. | m | 24.78 | 24.78 | 180.0 | False | None | None | False | None | False | 4460.4 | 0 | 3662916 | 133689 | None | Page-35-8.3-Vol-6 | Supplying and drawing PVC insulated gas injected physical foam
jelly flooded co-axial TV cable.RG-6. as per direction of Engineer in charge. | m | 51.92 | 51.92 | 80.0 | False | None | None | False | None | False | 4153.6 | 0 | 3662917 | 133689 | None | Page-35-8.4.4-Vol-6 | Supplying & Fixing of switch mounting rack with power manager &
Cable manager.-12U with 450mm depth | Each | 10425.3 | 10425.3 | 1.0 | False | None | None | False | None | False | 10425.3 | 0 | 3662918 | 133689 | None | Page-35-8.9.11-Vol-6 | Supplying fixing of Network Switches-16 port 10-100-1000 Switch as per direction of Engineer in charge. | Each | 7599.2 | 7599.2 | 1.0 | False | None | None | False | None | False | 7599.2 | 0 | 3662919 | 133689 | None | Page-35-8.10.1-Vol-6 | Supplying & fixing of I-O socket with back box-Single I-O as per direction of Engineer in charge. | Each | 578.2 | 578.2 | 18.0 | False | None | None | False | None | False | 10407.6 | 0 | 3662920 | 133689 | None | Page- 36-8.11.3-Vol-6 | Supplying & Fixing of ... Mtrs Cat 6 Patch Cable. 3mtr as per direction of Engineer in charge. | Each | 390.58 | 390.58 | 12.0 | False | None | None | False | None | False | 4686.96 | 0 | 3662921 | 133689 | None | Page- 36-8.12.2-Vol-6 | Supplying & Fixing of Patch panel for LAN cabling. 24 Port 101100 patch panel as per direction of Engineer in charge. | Each | 4838.0 | 4838.0 | 1.0 | False | None | None | False | None | False | 4838.0 | 0 | 3662922 | 133689 | None | Page-36-8.13.1-Vol-6 | Supplying and fixing of MDF krone junction box with KRONE
Module - Telephone cable termination.-10 Pair as per direction of Engineer in charge. | m | 407.1 | 407.1 | 1.0 | False | None | None | False | None | False | 407.1 | 0 | 3662923 | 133689 | None | Page-13-5.7.3-Vol-6 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden-panel using necessary nuts, bolts and washers. 63 A as per direction of Engineer in charge. | Each | 473.18 | 473.18 | 6.0 | False | None | None | False | None | False | 2839.08 | 0 | 3662924 | 133689 | None | Page-14-5.12.1-Vol-6 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SMEnclosure Sheet Metal Execution) 63 A as per direction of Engineer in charge. | Each | 8119.58 | 8119.58 | 1.0 | False | None | None | False | None | False | 8119.58 | 0 | 3662925 | 133689 | None | Page-16-5.15.9-Vol-6 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood-panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS-IEC 60947-2 . (Icu=100 lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit-Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.100 A 25 kA as per direction of Engineer in charge. | Each | 10014.66 | 10014.66 | 1.0 | False | None | None | False | None | False | 10014.66 | 0 | 3662926 | 133689 | None | Page-16-5.18.7-Vol-6 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON-OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6-32 A TPN as per direction of Engineer in charge. | Each | 2026.06 | 2026.06 | 5.0 | False | None | None | False | None | False | 10130.3 | 0 | 3662927 | 133689 | None | Page-17-5.21-Vol-6 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay-auto- manual reset facility suitable to mount on DIN rail- flush mounting on panel board.as per direction of Engineer in charge. | Each | 10920.9 | 10920.9 | 1.0 | False | None | None | False | None | False | 10920.9 | 0 | 3662928 | 133689 | None | Page-18-5.29-Vol-6 | Supplying, fixing and wiring 3 Phase Digital A mmeter - Voltmeter as per direction of Engineer in charge. | Each | 1681.5 | 1681.5 | 1.0 | False | None | None | False | None | False | 1681.5 | 0 | 3662929 | 133689 | None | Page-18-5.34-Vol-6 | Supplying, fixing and wiring 50-5 to 400-5A 5VA burden Current
Transformer Class 0.5 accuracy with Tape Wound.as per direction of Engineer in charge. | Each | 663.16 | 663.16 | 3.0 | False | None | None | False | None | False | 1989.48 | 0 | 3662930 | 133689 | None | Page-18-5.38-Vol-6 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230-440VAC. 50 Hz 12-24V D.C.as per direction of Engineer in charge. | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 | 3662931 | 133689 | None | Page-19-5.40.1-Vol-6 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic-FRP-DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete-100 A 4 x 30 x 6 mm Aluminium Strips as per direction of Engineer in charge. | m | 2908.7 | 2908.7 | 0.75 | False | None | None | False | None | False | 2181.525 | 0 | 3662932 | 133689 | None | Page-19-5.41.1-Vol-6 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint-40 x 40 x 6 mm as per direction of Engineer in charge. | m | 359.9 | 359.9 | 8.0 | False | None | None | False | None | False | 2879.2 | 0 | 3662933 | 133689 | None | Page-19-5.42.2-Vol-6 | Fabricating supplying and mounting MS box made out SWG
suitable for floor -wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete-16 SWG as per direction of Engineer in charge. | Sqm | 0.51 | 0.51 | 56000.0 | False | None | None | False | None | False | 28560.0 | 0 | 3662934 | 133689 | None | Page-2-1.9.2-Vol-6 | Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm as per direction of Engineer in charge. | m | 25.96 | 25.96 | 18.0 | False | None | None | False | None | False | 467.28 | 0 | 3662935 | 133689 | None | Page-54-12.58.7-Vol-6 | GI-Copper strips for grounding connections, using necessary fixing materials as required.25 x 3 mm Copper strip as per direction of Engineer in charge. | m | 672.6 | 672.6 | 30.0 | False | None | None | False | None | False | 20178.0 | 0 | 3662936 | 133689 | None | Page-53-12.57-Vol-6 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.as per direction of Engineer in charge. | No | 5022.08 | 5022.08 | 3.0 | False | None | None | False | None | False | 15066.24 | 0 | 3662937 | 133689 | None | ESR-Page-21-32.02-Vol-6 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5 and resistivity 14 Ohms-Kms (Max) as per IS-3975. 2 core 10 sq mm as per direction of Engineer in charge. | Km | 93493.76 | 93493.76 | 0.12 | False | None | None | False | None | False | 11219.2512 | 0 | 3662938 | 133689 | None | ESR-Page-21-32.05-Vol-6 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5 and resistivity 14 Ohms-Kms (Max) as per IS-3975. 4 core 16 sq mm as per direction of Engineer in charge. | Km | 167373.56 | 167373.56 | 0.18 | False | None | None | False | None | False | 30127.2408 | 0 | 3662939 | 133689 | None | ESR-Page-21-32.11-Vol-6 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5 and resistivity 14 Ohms-Kms (Max) as per IS-3975. 3.5 core 50sq mm as per direction of Engineer in charge. | Km | 211188.14 | 211188.14 | 0.22 | False | None | None | False | None | False | 46461.3908 | 0 | 3662940 | 133689 | None | ESR-Page-60-21.05-Vol-6 | Laying of LT cable in Existing Trench-GI pipe-Stone Ware-RCC Hume pipe using Wooden-Aluminum Rollers as directed by the departmental staff. 2.5 to 25 Sqmm as per direction of Engineer in charge. | Km | 24645.48 | 24645.48 | 0.28 | False | None | None | False | None | False | 6900.7344 | 0 | 3662941 | 133689 | None | ESR-Page-60-21.06-Vol-6 | Laying of LT cable in Existing Trench-GI pipe-Stone Ware-RCC Hume pipe using Wooden-Aluminum Rollers as directed by the departmental staff. 35 to 95 Sqmm as per direction of Engineer in charge. | Km | 36744.02 | 36744.02 | 0.22 | False | None | None | False | None | False | 8083.6844 | 0 | 3662942 | 133689 | None | CSR-Page-6-1.6.1-Vol-1 | Earth work excavation for pipelines-cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m as per direction of Engineer in charge. | m | 571.12 | 571.12 | 140.0 | False | None | None | False | None | False | 79956.8 | 0 | 3662943 | 133689 | None | ESR-Page-36-63.03-Vol-6 | Supplying and fixing of heavy duty Brass Cable Gland. 45 mm dia as per direction of Engineer in charge. | Each | 232.46 | 232.46 | 8.0 | False | None | None | False | None | False | 1859.68 | 0 | 3662944 | 133689 | None | Page-44-11.7.1-Vol-6 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate- clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr- Lumen Maintenance of 70 , CCT - 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire - IK08. Power Factor-0.9 with mains, Surge Protection- Min 5KV along with Over voltage-Overload, short circuit- miss-wiring protection. Compatible for pole mounting with outer dia of 40 mm to 50 mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50-60Hz application. Compliance to IS 10322- IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency-130 lm-w, nominal CRI -75. Luminaire manufacturer should have in- house facility accredited by NABL-CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark -name shall be Engraved - Embossing on the die cast housing- Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree-Nichia- Lumileds-Osram make LED Source. LED Post Top Lantern with 25 W for gate | No | 8167.96 | 8167.96 | 2.0 | False | None | None | False | None | False | 16335.92 | 0 | 3662945 | 133689 | None | Page-45-11.8.3-Vol-6 | Supply of 70 watts LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr - Lumen Maintenance of 70 , maximum light intensity should be between 60 degrees to 70 degrees. CCT - 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire - IK08. Power Factor -0.9 with mains, Surge Protection- Min 5KV along with Over voltage- Overload, short circuit- miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50-60Hz application. Compliance to IS 10322-IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency-1301m-w, nominal CRI -75. Luminaire manufacturer should have in-house facility accredited by NABL-CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark -name shall be Engraved - Embossing on the die cast housing- Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree-Nichia- Lumileds-Osram make LED Source.-LED Streetlight 70W as per direction of Engineer in charge. | Each | 7070.56 | 7070.56 | 6.0 | False | None | None | False | None | False | 42423.36 | 0 | 3662946 | 133689 | None | Page-55-13.1.1-Vol-6 | Supplying and Fixing of mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole - wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires.Using 25mm dia G.I.Pipe as per direction of Engineer in charge. | Each | 1154.04 | 1154.04 | 6.0 | False | None | None | False | None | False | 6924.24 | 0 | 3662947 | 133689 | None | CSR-page-157-13.40.1-Vol-5 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments.2 HP, Size 65x50 Head 13M, Discharge 462 LPM as per direction of Engineer in charge. | Each | 18419.8 | 18419.8 | 1.0 | False | None | None | False | None | False | 18419.8 | 0 | 3662948 | 133689 | None | CSR-page-157-13.40.1-Vol-5 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments.3 HP, size 50x40 Head 30M, Discharge 198 LPM as per direction of Engineer in charge. | Each | 22202.88 | 22202.88 | 1.0 | False | None | None | False | None | False | 22202.88 | 0 | 3662949 | 133689 | None | CSR-page-152-13.13.6-Vol-5 | Providing Submersible Pump Set of 150mm dia suitable for bore well and
confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt
Motor as per specifications, to work site as per necessary ammendments
and instructions of engineer incharge of work. 5.00 HP - 90 LPM - 110 m = 15 STG Outlet Dia - 2.00"etc. complete as per direction of Engineer in charge. | Set | 37921.66 | 37921.66 | 1.0 | False | None | None | False | None | False | 37921.66 | 0 | 3662950 | 133689 | None | Page-6-2.6.1-Vol-6 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 2.5 sq mm as per direction of Engineer in charge. | m | 138.06 | 138.06 | 60.0 | False | None | None | False | None | False | 8283.6 | 0 | 3662951 | 133689 | None | Page-6-2.6.2-Vol-6 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 4 sq mm as per direction of Engineer in charge. | m | 198.24 | 198.24 | 160.0 | False | None | None | False | None | False | 31718.4 | 0 | 3662952 | 133689 | None | CSR-page-98-9.5.1-Vol-5 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 16.0-63mm dia as per direction of Engineer in charge. | m | 385.86 | 385.86 | 140.0 | False | None | None | False | None | False | 54020.4 | 0 | 3662953 | 133689 | None | Page-155-13.23.1-Vol-5 | Supply, installing,testing and commissioning COMMON control panel
consisting of the following INCOMING:1 No set of Phase indicating
lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S-D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE:
1) DOL- Direct Online Starter Upto 3 HP pumps as per direction of Engineer in charge. | Each | 7670.0 | 7670.0 | 2.0 | False | None | None | False | None | False | 15340.0 | 0 | 3662954 | 133689 | None | Page-155-13.23.1-Vol-5 | Supply, installing,testing and commissioning COMMON control panel
consisting of the following INCOMING:1 No set of Phase indicating
lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S-D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE:
1) DOL- Direct Online Starter above 3 to 6 HP pumps as per direction of Engineer in charge. | Each | 11269.0 | 11269.0 | 1.0 | False | None | None | False | None | False | 11269.0 | 0 | 3662955 | 133689 | None | CSR-Page-154-13.24.1-Vol-5 | Supply and delivery at site of brand new best make gate valve as per IS 778-1984 with ISI Mark and as per its latest amendments 50 mm dia.as per direction of Engineer in charge. | No | 1475.0 | 1475.0 | 2.0 | False | None | None | False | None | False | 2950.0 | 0 | 3662956 | 133689 | None | CSR-Page-154-13.25.1-Vol-5 | Supply and delivery at site of brand new best makeNon -return valve as per IS 778-1984 with ISI Mark and as per its latest amendments 50 mm dia.as per direction of Engineer in charge. | No | 1475.0 | 1475.0 | 2.0 | False | None | None | False | None | False | 2950.0 | 0 | 3662957 | 133689 | None | BSR-18-19-41.10 | Supplying & fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together & fixed in C.C (1:2:4) with 2 nos 16 mm dia MS . Hold fast rods each of length 25cms. Including cost of all materials cutting, bending scaffolding wherever neccessary, nicely finishing the welded joints with all lead lifts and as per the directions of the engineer-in-charge of the work and including providing 2 coats of approved quality paint over one coat of shop painting ( excluding cost of earthwork and concrete) including cost of materials, labour, HOM complete as per specifications.as per direction of Engineer in charge. | m | 1013.62 | 1013.62 | 22.0 | False | None | None | False | None | False | 22299.64 | 0 | 3662958 | 133689 | None | BSR-Page-6-22.03-P-3 | Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt & nuts, the free ends shall be welded to the pole & black pipe at top & bottom as required including cost of all materials, labour,lead and lifts and as per the directions of engineer-in-charge of the work including two coats of approved quality paint over one coat of shop paint, including cost of materials, labour, HOM complete as per specifications.as per direction of Engineer in charge. | Sqm | 843.7 | 843.7 | 32.0 | False | None | None | False | None | False | 26998.4 | 0 | 3662959 | 133689 | None | CSR-18-19-4.6 | KSRB 4-1.6 : Providing & laying in position Plain cement concrete of Mix 1:2:4 with OPC-240 kgs, with 20mm and down size graded granite metal coarse aggregates - 0.878 cum and fine aggregates - 0,53 cum, machine mixed, concrete laid in layes not exeeding 15 cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM curing complete as per specifications.as per direction of Engineer in charge. | Cum | 7105.96 | 7105.96 | 0.5 | False | None | None | False | None | False | 3552.98 | 0 | 3662960 | 133689 | None | Page-19-5.41.1-Vol-6 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint-40 x 40 x 6 mm as per direction of Engineer in charge. | m | 359.9 | 359.9 | 22.0 | False | None | None | False | None | False | 7917.8 | 0 | 3662961 | 133689 | None | ESR-Page-15-13.01-Vol-6 | Distribution Transformer - 3 Phase,11kV-433V - Amorphous Core with Oil as per IS-1180 (Part-1): 2014 OPEN BUSHING TYPE 25 kVA, Aluminium Wdg, Star 2 (5 Star)as per direction of Engineer in charge. | Each | 125999.22 | 125999.22 | 1.0 | False | None | None | False | None | False | 125999.22 | 0 | 3662962 | 133689 | None | ESR-Page-17-18.01-Vol-6 | LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) (Dwg No. BESCOM-GM-QS&S-58 Dtd 24.11.2018)as per direction of Engineer in charge. | No | 26769.48 | 26769.48 | 1.0 | False | None | None | False | None | False | 26769.48 | 0 | 3662963 | 133689 | None | ESR-Page-17-17.01-Vol-6 | LT Protection kit (Dwg No. BESCOM-GM-QS&S-10 Dtd 24.11.2018 as per direction of Engineer in charge. | No | 2387.14 | 2387.14 | 1.0 | False | None | None | False | None | False | 2387.14 | 0 | 3662964 | 133689 | None | ESR-Page-18-21.08-Vol-6 | Double Pole TC Sets for erection of Transformers on RCC-PSCC 9 Mtrs Long Poles as per IS-1977, For 100-300kVA 4-5 Star Rated Transformers using 9 mtr RCC Pole 145Kg WL - GI as per direction of Engineer in charge. | Set | 36218.92 | 36218.92 | 1.0 | False | None | None | False | None | False | 36218.92 | 0 | 3662965 | 133689 | None | ESR-Page-19-24.01-Vol-6 | GOS as per IS-9921, IS-1977 11kV, 200 Amps Single Break GOS (Dwg No. BESCOM-GM-QS&S-23 Dtd 24.11.2018) as per direction of Engineer in charge. | Set | 11151.0 | 11151.0 | 1.0 | False | None | None | False | None | False | 11151.0 | 0 | 3662966 | 133689 | None | ESR-Page-20-25.01-Vol-6 | DOLO Cutouts as per IS-9385, Part-1 to 3, 11kV DOLO Cutouts Conventional to Erstwhile KEB Specification (Dwg No. BESCOM-GM-QS&S-20 Dtd 24.11.2018) as per direction of Engineer in charge. | Set of 3 Nos | 6932.5 | 6932.5 | 1.0 | False | None | None | False | None | False | 6932.5 | 0 | 3662967 | 133689 | None | ESR-Page-11-1.01-Vol-6 | RCC Pole - 9 Mtr Long, 150 Kg WL Sq Section (Dwg No. BESCOM-GM-QS&S-51 Dtd 24.11.2018) as per IS-785 as per direction of Engineer in charge. | No | 8349.68 | 8349.68 | 9.0 | False | None | None | False | None | False | 75147.12 | 0 | 3662968 | 133689 | None | ESR-Page-11-1.06-Vol-6 | PSCC Pole - 9 Mtr Long, 200 Kg WL (Dwg No.(Dwg No. BESCOM-GM-QS&S-50 Dtd 24.11.2018) as per REC Standards as per direction of Engineer in charge. | Nos | 4954.82 | 4954.82 | 8.0 | False | None | None | False | None | False | 39638.56 | 0 | 3662969 | 133689 | None | ESR-Page-11-2.02-Vol-6 | Cross Arms (MS & GI) as per IS-1977 11kV Horizontal X Arms - Galvanised Iron (GI) as per direction of Engineer in charge. | No | 574.66 | 574.66 | 18.0 | False | None | None | False | None | False | 10343.88 | 0 | 3662970 | 133689 | None | ESR-Page-11-2.03-Vol-6 | Cross Arms (MS & GI) as per IS-1977 11kV Special 3 Pin X Arm - MS (Dwg No. BESCOM-GM-QS&S-03 Dtd 24.11.2018) as per direction of Engineer in charge. | No | 1037.22 | 1037.22 | 1.0 | False | None | None | False | None | False | 1037.22 | 0 | 3662971 | 133689 | None | ESR-Page-12-2.12-Vol-6 | HT ST Support 50x6mm Flat - GI as per direction of Engineer in charge. | No | 142.78 | 142.78 | 12.0 | False | None | None | False | None | False | 1713.36 | 0 | 3662972 | 133689 | None | ESR-Page-13-6.06-Vol-6 | 11kV, 5KN Composite-Polymeric Pin Insulator (24mm dia FRP Rod) as per direction of Engineer in charge. | No | 241.9 | 241.9 | 38.0 | False | None | None | False | None | False | 9192.2 | 0 | 3662973 | 133689 | None | ESR-Page-13-6.10-Vol-6 | 11kV, 45kN Polymeric Insulator as per direction of Engineer in charge. | No | 219.48 | 219.48 | 6.0 | False | None | None | False | None | False | 1316.88 | 0 | 3662974 | 133689 | None | ESR-Page-8-24.a-Vol-6 | Guy set complete with No.15 strain insulator & Cocreting matrials as per direction of Engineer in charge. | Set | 699.74 | 699.74 | 6.0 | False | None | None | False | None | False | 4198.44 | 0 | 3662975 | 133689 | None | ESR-Page-53-5.10-Vol-6 | Fixing of GUY Set with break insulator making use of 7-3.15 mm (7-10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT)as per direction of Engineer in charge. | Per Set | 313.88 | 313.88 | 6.0 | False | None | None | False | None | False | 1883.28 | 0 | 3662976 | 133689 | None | BSR-Page-3-7.02-P-3 | Rabbit ACSR(6-3.35 mm Al + 1-3.35 mm St), Std Wt: 214 Kg-KM as per direction of Engineer in charge. | Km | 54556.12 | 54556.12 | 0.9 | False | None | None | False | None | False | 49100.508 | 0 | 3662977 | 133689 | None | ESR-Page-12-2.16-Vol-6 | Spiral Earth Electrode as per direction of Engineer in charge. | No | 282.02 | 282.02 | 26.0 | False | None | None | False | None | False | 7332.52 | 0 | 3662978 | 133689 | None | ESR-Page-12-2.15-Vol-6 | EG Stirrup (MS) with GI wire lacing as per direction of Engineer in charge. | No | 325.68 | 325.68 | 24.0 | False | None | None | False | None | False | 7816.32 | 0 | 3662979 | 133689 | None | ESR-Page-40-68.17-Vol-6 | Caution-Danger Board as per direction of Engineer in charge. | No | 177.0 | 177.0 | 8.0 | False | None | None | False | None | False | 1416.0 | 0 | 3662980 | 133689 | None | ESR-Page-12-4.02-Vol-6 | Anti climbing device GI Barbed wire (12mtrs-Kg) as per direction of Engineer in charge. | Each | 105.02 | 105.02 | 17.0 | False | None | None | False | None | False | 1785.34 | 0 | 3662981 | 133689 | None | DGS & D Rates | Solar Street Light System With Mounting Structure & Pole ( MNES Specification) Description of item: 2 X 18 W LED ,PV Module: 120 W,Battery Capacity: 12 V ,100 AH as per direction of Engineer in charge. | Nos | 40392.58 | 40392.58 | 6.0 | False | None | None | False | None | False | 242355.48 | 0 | 3662982 | 133689 | None | NSR | Supplying and fixing Industrial bell as per direction of Engineer in charge. | Each | 9440.0 | 9440.0 | 1.0 | False | None | None | False | None | False | 9440.0 | 0 |
|
|
---|