3689460 | 135463 | None | code01 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 14557.54 | 14557.54 | 7.97 | False | None | None | False | None | False | 116023.5938 | 0 |
3689461 | 135463 | None | code02 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators,providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).SRP- Vol-I (17/2.4.1) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8013.89 | 8013.89 | 2.02 | False | None | None | False | None | False | 16188.0578 | 0 |
3689462 | 135463 | None | code03 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately).SRP- Vol-I (17/2.5.2) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 13701.21 | 13701.21 | 10.95 | False | None | None | False | None | False | 150028.2495 | 0 |
3689463 | 135463 | None | code04 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internalframe with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed andfastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 35 mm thick both side Teak (105/12.57.4) | Sqm | 5671.3 | 5671.3 | 12.96 | False | None | None | False | None | False | 73500.048 | 0 |
3689464 | 135463 | None | code05 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 155425.13 | 155425.13 | 0.36 | False | None | None | False | None | False | 55953.0468 | 0 |
3689465 | 135463 | None | code06 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 210.22 | 210.22 | 680.4 | False | None | None | False | None | False | 143033.688 | 0 |
3689466 | 135463 | None | code07 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. SRP- Voll (14/6.8) | Cum | 9972.32 | 9972.32 | 71.19 | False | None | None | False | None | False | 709929.4608 | 0 |
3689467 | 135463 | None | code08 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Voll (41/8.2.1) | Sqm | 369.16 | 369.16 | 260.34 | False | None | None | False | None | False | 96107.1144 | 0 |
3689468 | 135463 | None | code09 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. SRP- Voll (41/8.1.1) | Sqm | 319.1 | 319.1 | 225.44 | False | None | None | False | None | False | 71937.904 | 0 |
3689469 | 135463 | None | code10 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel crews, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. SRP- Voll (87/11.35.1.2) | Kg | 611.92 | 611.92 | 193.23 | False | None | None | False | None | False | 118241.3016 | 0 |
3689470 | 135463 | None | code11 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, sage charges of machinery complete as per specifications. SRP- Voll (89/ 11.37.2) | Sqm | 1465.38 | 1465.38 | 33.84 | False | None | None | False | None | False | 49588.4592 | 0 |
3689471 | 135463 | None | code12 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm SRP- Vol-ll (62/ 9.22.2) | Sqm | 1659.33 | 1659.33 | 223.38 | False | None | None | False | None | False | 370661.1354 | 0 |
3689472 | 135463 | None | code13 | Supplying, fitting and placing TMT FE 550/550D Steel Reinforcement complete as per drawing and technical specification. Building works SRP- Vol-l (18/ 2.11a) | Kg | 111945.59 | 111945.59 | 2.85 | False | None | None | False | None | False | 319044.9315 | 0 |
3689473 | 135463 | None | code14 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Vol-Il (50/ 8.51) | Sqm | 125.13 | 125.13 | 260.34 | False | None | None | False | None | False | 32576.3442 | 0 |
3689474 | 135463 | None | code15 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-II (45/ 8.25) | Sqm | 171.44 | 171.44 | 260.34 | False | None | None | False | None | False | 44632.6896 | 0 |
3689475 | 135463 | None | code16 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol-II (45/ 8.28) | Sqm | 111.36 | 111.36 | 225.44 | False | None | None | False | None | False | 25104.9984 | 0 |
3689476 | 135463 | None | code17 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (SRP-Vol-II/123/13.34) | Ltr | 11.25 | 11.25 | 1000.0 | False | None | None | False | None | False | 11250.0 | 0 |
3689477 | 135463 | None | code18 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal dia Pipes (SRP-Vol-II/123/13.33.5) | Mtr | 596.91 | 596.91 | 40.0 | False | None | None | False | None | False | 23876.4 | 0 |
3689478 | 135463 | None | code19 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes (SRP-Vol-II/123/13.33.3) | Mtr | 370.41 | 370.41 | 30.0 | False | None | None | False | None | False | 11112.3 | 0 |
3689479 | 135463 | None | code20 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes (SRP-Vol-II/123/13.33.2) | Mtr | 271.55 | 271.55 | 60.0 | False | None | None | False | None | False | 16293.0 | 0 |
3689480 | 135463 | None | code21 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 15 mm nominal dia Pipes (SRP-Vol-II/123/13.33.1) | Mtr | 207.72 | 207.72 | 50.0 | False | None | None | False | None | False | 10386.0 | 0 |
3689481 | 135463 | None | code22 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (SRP-Vol-II/132/14.7.4) | Each | 2934.5 | 2934.5 | 2.0 | False | None | None | False | None | False | 5869.0 | 0 |
3689482 | 135463 | None | code23 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm (SRP-Vol-II/134/14.13.2) | Each | 2916.98 | 2916.98 | 6.0 | False | None | None | False | None | False | 17501.88 | 0 |
3689483 | 135463 | None | code24 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (SRP-Vol-II/131/14.2.1) | Each | 5994.28 | 5994.28 | 2.0 | False | None | None | False | None | False | 11988.56 | 0 |
3689484 | 135463 | None | code25 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (SRP-Vol-II/136/14.31) | Unit | 1511.58 | 1511.58 | 2.0 | False | None | None | False | None | False | 3023.16 | 0 |
3689485 | 135463 | None | code26 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete (SRP-Vol-II/127/13.59) | Nos | 272.58 | 272.58 | 2.0 | False | None | None | False | None | False | 545.16 | 0 |
3689486 | 135463 | None | code27 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore (SRP-Vol-II/117/13.5.1) | Nos | 366.74 | 366.74 | 5.0 | False | None | None | False | None | False | 1833.7 | 0 |
3689487 | 135463 | None | code28 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore (SRP-Vol-II/117/13.4.3) | Nos | 869.77 | 869.77 | 2.0 | False | None | None | False | None | False | 1739.54 | 0 |
3689488 | 135463 | None | code29 | Providing and fixing brass stop cock of approved quality 15 mm nominal bore (SRP-Vol-II/117/13.3.1) | Nos | 370.46 | 370.46 | 8.0 | False | None | None | False | None | False | 2963.68 | 0 |
3689489 | 135463 | None | code30 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (SRP-Vol-II/60/9.11) | Sqm | 1101.47 | 1101.47 | 7.96 | False | None | None | False | None | False | 8767.7012 | 0 |
3689490 | 135463 | None | code31 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. (SRP-Vol-II/63/9.24) | Sqm | 3533.62 | 3533.62 | 7.56 | False | None | None | False | None | False | 26714.1672 | 0 |
3689491 | 135463 | None | code32 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In cement mortar (SRP-Vol-II/187/19.7.3) | Cum | 1274.93 | 1274.93 | 6.72 | False | None | None | False | None | False | 8567.5296 | 0 |
3689492 | 135463 | None | code33 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. (SRP-Vol-II/187/19.3) | Cum | 2949.02 | 2949.02 | 6.57 | False | None | None | False | None | False | 19375.0614 | 0 |
3689493 | 135463 | None | code34 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (SRP-Vol-II/65/9.39) | Sqm | 1813.25 | 1813.25 | 11.0 | False | None | None | False | None | False | 19945.75 | 0 |
3689494 | 135463 | None | code35 | Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame. Flat surfaces (SRP-Vol-II/24/7.28.1) | Sqm | 1594.27 | 1594.27 | 78.88 | False | None | None | False | None | False | 125756.0176 | 0 |
3689495 | 135463 | None | code36 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (SRP-Vol-II/83/11.16.3) | Kg | 152.66 | 152.66 | 4301.28 | False | None | None | False | None | False | 656633.4048 | 0 |
3689496 | 135463 | None | code37 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required (SRP-Vol-II/26/7.38) | Sqm | 710.78 | 710.78 | 266.54 | False | None | None | False | None | False | 189451.3012 | 0 |
3689497 | 135463 | None | code38 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (SRP-Vol-II/65/9.38) | Sqm | 1724.68 | 1724.68 | 43.68 | False | None | None | False | None | False | 75334.0224 | 0 |
3689498 | 135463 | None | code39 | SRP: 1.3.2 -Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick | Mtr | 97.88 | 97.88 | 140.0 | False | None | None | False | None | False | 13703.2 | 0 |
3689499 | 135463 | None | code40 | 1.1.2 Open Conduit System:Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structureor rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25mm dia 2mm thick | Mtr | 100.35 | 100.35 | 60.0 | False | None | None | False | None | False | 6021.0 | 0 |
3689500 | 135463 | None | code41 | SRP:2.3:Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm 2.3.2 | Mtr | 32.21 | 32.21 | 251.0 | False | None | None | False | None | False | 8084.71 | 0 |
3689501 | 135463 | None | code42 | SRP:2.3:Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm (P6/2.3.3) | Mtr | 52.03 | 52.03 | 750.0 | False | None | None | False | None | False | 39022.5 | 0 |
3689502 | 135463 | None | code43 | SRP:2.3:Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4sqmm (P6/2.3.4) | Mtr | 78.05 | 78.05 | 150.0 | False | None | None | False | None | False | 11707.5 | 0 |
3689503 | 135463 | None | code44 | SRP:2.3:Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6sqmm (P6/2.3.5) | Mtr | 113.98 | 113.98 | 25.0 | False | None | None | False | None | False | 2849.5 | 0 |
3689504 | 135463 | None | code45 | SRP:2.2.1:Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box | No | 333.29 | 333.29 | 6.0 | False | None | None | False | None | False | 1999.74 | 0 |
3689505 | 135463 | None | code46 | SRP:2.2.1:Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3 Mtr upto 6Mtr from tapping point to outlet via switch box. (P5/2.2.2) | No | 469.58 | 469.58 | 15.0 | False | None | None | False | None | False | 7043.7 | 0 |
3689506 | 135463 | None | code47 | SRP:2.2.1:Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6 Mtr upto 10Mtr from tapping point to outlet via switch box. (P5/2.2.3) | No | 687.64 | 687.64 | 30.0 | False | None | None | False | None | False | 20629.2 | 0 |
3689507 | 135463 | None | code48 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.1-3Way 3.4.1 | No | 170.98 | 170.98 | 2.0 | False | None | None | False | None | False | 341.96 | 0 |
3689508 | 135463 | None | code49 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 4-5way (P15/3.4.3) | No | 219.3 | 219.3 | 6.0 | False | None | None | False | None | False | 1315.8 | 0 |
3689509 | 135463 | None | code50 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 6 way (P15/3.4.4) | No | 272.58 | 272.58 | 5.0 | False | None | None | False | None | False | 1362.9 | 0 |
3689510 | 135463 | None | code51 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 10-12 way (P15/3.4.6) | No | 395.24 | 395.24 | 14.0 | False | None | None | False | None | False | 5533.36 | 0 |
3689511 | 135463 | None | code52 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module 3.5.1 | No | 169.74 | 169.74 | 2.0 | False | None | None | False | None | False | 339.48 | 0 |
3689512 | 135463 | None | code53 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 4 mod (P16/3.5.3) | No | 216.82 | 216.82 | 6.0 | False | None | None | False | None | False | 1300.92 | 0 |
3689513 | 135463 | None | code54 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Module (P16/3.5.4) | No | 289.92 | 289.92 | 5.0 | False | None | None | False | None | False | 1449.6 | 0 |
3689514 | 135463 | None | code55 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 10-12 Module (P16/3.5.6) | No | 426.21 | 426.21 | 14.0 | False | None | None | False | None | False | 5966.94 | 0 |
3689515 | 135463 | None | code56 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch 3.6.1 | No | 126.37 | 126.37 | 70.0 | False | None | None | False | None | False | 8845.9 | 0 |
3689516 | 135463 | None | code57 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3 way socket (P16/3.6.3) | No | 211.86 | 211.86 | 20.0 | False | None | None | False | None | False | 4237.2 | 0 |
3689517 | 135463 | None | code58 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. modular stepped fan regulator (P16/3.6.4) | No | 442.32 | 442.32 | 18.0 | False | None | None | False | None | False | 7961.76 | 0 |
3689518 | 135463 | None | code59 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch (P16/3.6.7) | No | 223.02 | 223.02 | 4.0 | False | None | None | False | None | False | 892.08 | 0 |
3689519 | 135463 | None | code60 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16 Amps universal socket (P16/3.6.10) | No | 292.4 | 292.4 | 4.0 | False | None | None | False | None | False | 1169.6 | 0 |
3689520 | 135463 | None | code61 | Supplying and fixing Fan box with round hook (P3/1.13) | No | 144.96 | 144.96 | 15.0 | False | None | None | False | None | False | 2174.4 | 0 |
3689521 | 135463 | None | code62 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 25mm 1.9.2 | Mtr | 27.25 | 27.25 | 10.0 | False | None | None | False | None | False | 272.5 | 0 |
3689522 | 135463 | None | code63 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.11.3.2 LED light fighting 1 x4'- 20/22 w | No | 854.91 | 854.91 | 25.0 | False | None | None | False | None | False | 21372.75 | 0 |
3689523 | 135463 | None | code64 | SRP 11.6.2 Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. Efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light LED modular down light 11.6.2 LED modular down light 1x1 24W | No | 4574.38 | 4574.38 | 10.0 | False | None | None | False | None | False | 45743.8 | 0 |
3689524 | 135463 | None | code65 | 11.8.4 Supply of LED Streetlight luminaire 90 watt with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source.LED Streetlight 90 Watts | No | 10977.54 | 10977.54 | 2.0 | False | None | None | False | None | False | 21955.08 | 0 |
3689525 | 135463 | None | code66 | 6.3.1. Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. | No | 3697.17 | 3697.17 | 14.0 | False | None | None | False | None | False | 51760.38 | 0 |
3689526 | 135463 | None | code67 | 6.2.1 Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300mm) 7.2.1 | No | 3678.59 | 3678.59 | 2.0 | False | None | None | False | None | False | 7357.18 | 0 |
3689527 | 135463 | None | code68 | Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall / ceiling / Rafter / Girders 13.7.1 | No | 151.15 | 151.15 | 30.0 | False | None | None | False | None | False | 4534.5 | 0 |
3689528 | 135463 | None | code69 | Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 40mm dia G.I.Pipe 13.2.3 | No | 1831.24 | 1831.24 | 6.0 | False | None | None | False | None | False | 10987.44 | 0 |
3689529 | 135463 | None | code70 | 6.5.1 Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply. | No | 3087.58 | 3087.58 | 5.0 | False | None | None | False | None | False | 15437.9 | 0 |
3689530 | 135463 | None | code71 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.13.10 | No | 211.86 | 211.86 | 19.0 | False | None | None | False | None | False | 4025.34 | 0 |
3689531 | 135463 | None | code72 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.13.13 | No | 875.97 | 875.97 | 2.0 | False | None | None | False | None | False | 1751.94 | 0 |
3689532 | 135463 | None | code73 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.5.18.1 6-32Amps SP | No | 514.18 | 514.18 | 4.0 | False | None | None | False | None | False | 2056.72 | 0 |
3689533 | 135463 | None | code74 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DP. (5.18.2) | No | 915.62 | 915.62 | 5.0 | False | None | None | False | None | False | 4578.1 | 0 |
3689534 | 135463 | None | code75 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps TPN. (5.18.7) | No | 2127.36 | 2127.36 | 1.0 | False | None | None | False | None | False | 2127.36 | 0 |
3689535 | 135463 | None | code76 | SRP 5.19.10 Supplying and fixing regular MCB distribution board sonwall/ oodboard/ flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3phase/ single door with powder coate dpainting Madeoutof14SWGMS enclosure 16 Way SP & | No | 3603.01 | 3603.01 | 1.0 | False | None | None | False | None | False | 3603.01 | 0 |
3689536 | 135463 | None | code77 | SRP3.14.6 Supplying And fixing/replacing of 6A Lamp Holder on existing switch board. | No | 87.96 | 87.96 | 28.0 | False | None | None | False | None | False | 2462.88 | 0 |