3686236 | 135214 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m [PWD SR 2023-24 Vol:1 P.NO.8 I.No:1.14.1] | Cum | 105.06 | 105.06 | 39.636 | False | None | None | False | None | False | 4164.15816 | 0 |
3686237 | 135214 | None | code02 | PCC (1:3:6) Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates [PWD SR 2023-24 Vol:I P.NO.15 I.No:2.1.3] | Cum | 6168.67 | 6168.67 | 4.8712 | False | None | None | False | None | False | 30048.825304 | 0 |
3686238 | 135214 | None | code03 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) [PWD SR 2023-24 Vol:I P.NO.9 I.No:5.4] | Cum | 6580.67 | 6580.67 | 18.103 | False | None | None | False | None | False | 119129.86901 | 0 |
3686239 | 135214 | None | code04 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. [PWD SR 2023-24 Vol:I P.NO.7 I.No:1.10] | Cum | 164.8 | 164.8 | 20.025 | False | None | None | False | None | False | 3300.12 | 0 |
3686240 | 135214 | None | code05 | RCC (M20) Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub-structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).M20 Design Mix Using 20 mm nominal size gradedcrushed coarse aggregates [PWD SR 2023-24 Vol:1 P.NO.16 I.No:2.4.2] For Plinth Beam considered 50% | Cum | 9769.03 | 9769.03 | 1.83 | False | None | None | False | None | False | 17877.3249 | 0 |
3686241 | 135214 | None | code06 | RCC (M20) Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub-structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately).M20 Design Mix Using 20 mm nominal size gradedcrushed coarse aggregates [PWD SR 2023-24 Vol:1 P.NO.16 I.No:2.4.2] For Well Foundations considered 10% | Cum | 7163.95 | 7163.95 | 3.9555 | False | None | None | False | None | False | 28337.004225 | 0 |
3686242 | 135214 | None | code07 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications..[PWD SR 2023-24 Vol:2 P.NO.17I.No: 6.32] | Sqm | 1349.3 | 1349.3 | 54.81 | False | None | None | False | None | False | 73955.133 | 0 |
3686243 | 135214 | None | code08 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.[PWD SR 2023-24 Vol:2 P.NO.17I.No: 6.34] | Sqm | 1137.12 | 1137.12 | 24.107 | False | None | None | False | None | False | 27412.55184 | 0 |
3686244 | 135214 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates [PWD SR 2023-24 Vol:1 P.NO.17 I.No:2.5.1] For Roof Beam considered 60% | Cum | 10926.24 | 10926.24 | 1.7112 | False | None | None | False | None | False | 18696.981888 | 0 |
3686245 | 135214 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates [PWD SR 2023-24 Vol:1 P.NO.17 I.No:2.5.1] For Roof Slab considered 50% | Cum | 10243.35 | 10243.35 | 1.558 | False | None | None | False | None | False | 15959.1393 | 0 |
3686246 | 135214 | None | code11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification [PWD SR 2023-24 Vol:1 P.NO.18 I.No: 2.11a] | Tonne | 92140.71 | 92140.71 | 0.99 | False | None | None | False | None | False | 91219.3029 | 0 |
3686247 | 135214 | None | code12 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.[PWD SR 2023-24 Vol:2 P.NO.83 I.No: 11.16.3 ] | Kg | 125.66 | 125.66 | 566.78 | False | None | None | False | None | False | 71221.5748 | 0 |
3686248 | 135214 | None | code13 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required..[PWD SR 2023-24 Vol:2 P.NO.26 I.No: 7.38] | Sqm | 585.04 | 585.04 | 31.487 | False | None | None | False | None | False | 18421.15448 | 0 |
3686249 | 135214 | None | code14 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smoot rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..[PWD SR 2023-24 Vol:2 P.NO.41 I.No: 8.1.2] | Sqm | 248.23 | 248.23 | 28.65 | False | None | None | False | None | False | 7111.7895 | 0 |
3686250 | 135214 | None | code15 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..[PWD SR 2023-24 Vol:2 P.NO.41 I.No: 8.3.2] | Sqm | 342.99 | 342.99 | 54.818 | False | None | None | False | None | False | 18802.02582 | 0 |
3686251 | 135214 | None | code16 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.[PWD SR 2023-24 Vol:2 P.NO.42 I.No: 8.8] | Sqm | 382.13 | 382.13 | 50.126 | False | None | None | False | None | False | 19154.64838 | 0 |
3686252 | 135214 | None | code17 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.[PWD SR 2023-24 Vol:2 P.NO.41 I.No: 8.2.1] | Sqm | 303.85 | 303.85 | 22.775 | False | None | None | False | None | False | 6920.18375 | 0 |
3686253 | 135214 | None | code18 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.[PWD SR 2023-24 Vol:2 P.NO.65 I.No: 9.38] | Sqm | 1433.76 | 1433.76 | 27.612 | False | None | None | False | None | False | 39588.98112 | 0 |
3686254 | 135214 | None | code19 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 500x500 mm [PWD SR 2023-24 Vol:2 P.NO.62 I.No: 9.22.1] | Sqm | 1288.53 | 1288.53 | 8.777 | False | None | None | False | None | False | 11309.42781 | 0 |
3686255 | 135214 | None | code20 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.[PWD SR 2023-24 Vol:2 P.NO.44 I.No: 8.19.1] | Sqm | 262.65 | 262.65 | 10.341 | False | None | None | False | None | False | 2716.06365 | 0 |
3686256 | 135214 | None | code21 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life).[PWD SR 2023-24 Vol:2 P.NO.46 I.No: 8.33.1] | Sqm | 162.74 | 162.74 | 77.594 | False | None | None | False | None | False | 12627.64756 | 0 |
3686257 | 135214 | None | code22 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) Size of Tile 500x500 mm [PWD SR 2023-24 Vol:2 P.NO.62 I.No:9.12.1] | Sqm | 1114.46 | 1114.46 | 8.8692 | False | None | None | False | None | False | 9884.368632 | 0 |
3686258 | 135214 | None | code23 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid [PWD SR 2023-24 Vol:2 P.NO.123 I.No:14.3.1] | Each | 6156.31 | 6156.31 | 6.0 | False | None | None | False | None | False | 36937.86 | 0 |
3686259 | 135214 | None | code24 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass,including painting of fittings and cutting and making good the walls and floors wherever required Single half stall urinal with 5 litre P.V.C. automatic flushing cistern [PWD SR 2023-24 Vol:2 P.NO.124 I.No:14.5.1] | Sqm | 8901.26 | 8901.26 | 5.0 | False | None | None | False | None | False | 44506.3 | 0 |
3686260 | 135214 | None | code25 | Providing and fixing M.S. grills of required pattern in frames of win dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. [PWD SR 2023-24 Vol:1 P.NO.7 I.No:11.34B] | Kg | 188.49 | 188.49 | 250.94 | False | None | None | False | None | False | 47299.6806 | 0 |
3686261 | 135214 | None | code26 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled
including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. [PWD SR 2023-24 Vol:2 P.NO.99 I.No:12.12] | Cum | 127928.06 | 127928.06 | 0.2028 | False | None | None | False | None | False | 25943.810568 | 0 |
3686262 | 135214 | None | code27 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) [PWD SR 2023-24 Vol:2 P.NO.100 I.No:12.15] | Sqm | 7103.91 | 7103.91 | 3.78 | False | None | None | False | None | False | 26852.7798 | 0 |
3686263 | 135214 | None | code28 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. [PWD SR 2023-24 Vol:2 P.NO.100 I.No:12.84] | Sqm | 327.54 | 327.54 | 29.0 | False | None | None | False | None | False | 9498.66 | 0 |
3686264 | 135214 | None | code29 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges [PWD SR 2023-24 Vol:2 P.NO.105 I.No:12.53] | Sqm | 1635.64 | 1635.64 | 8.4 | False | None | None | False | None | False | 13739.376 | 0 |
3686265 | 135214 | None | code30 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 600x450x200 mm [PWD SR 2023-24 Vol:2 P.NO.126 I.No:14.11.2] | Sqm | 5234.46 | 5234.46 | 2.0 | False | None | None | False | None | False | 10468.92 | 0 |
3686266 | 135214 | None | code31 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall [PWD SR 2023-24 Vol:2 P.NO.122 I.No:13.31.2] | m | 249.26 | 249.26 | 50.0 | False | None | None | False | None | False | 12463.0 | 0 |
3686267 | 135214 | None | code32 | Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 20 mm dia GM (Copper alloy) Gate valves [Common SR Water Supply 2023-24 Vol:5 P.NO.133 I.No:1.15.2] | Each | 914.64 | 914.64 | 2.0 | False | None | None | False | None | False | 1829.28 | 0 |
3686268 | 135214 | None | code33 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 65x50 Head 13M, Discharge 462 LPM [Common SR Water Supply 2023-24 Vol:5 P.NO.157 I.No:13.40.1] | Each | 16078.3 | 16078.3 | 1.0 | False | None | None | False | None | False | 16078.3 | 0 |
3686269 | 135214 | None | code34 | Supply and delivery at site brand new best make Foot valve suitable for centrifugal pump upto 10HP confirming with ISI mark and its latest amendments [Common SR Water Supply 2023-24 Vol:5 P.NO.158 I.No:13.47] | Each | 1802.5 | 1802.5 | 1.0 | False | None | None | False | None | False | 1802.5 | 0 |
3686270 | 135214 | None | code35 | Supply and delivery at site brand new best make starter/ control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments.Upto 7.5 HP centrifugal pump [Common SR Water Supply 2023-24 Vol:5 P.NO.157 I.No:13.43.1] | Each | 9785.0 | 9785.0 | 1.0 | False | None | None | False | None | False | 9785.0 | 0 |
3686271 | 135214 | None | code36 | Supplying and fixing LT cable of size 4 x 25 Sqm suitable for centrifugal pump sets with ISI mark and its latest amendments [Common SR Water Supply 2021-22 Vol:2 P.NO.158 I.No:13.46] | m | 578.86 | 578.86 | 1.0 | False | None | None | False | None | False | 578.86 | 0 |
3686272 | 135214 | None | code37 | Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 1000 litre capacity) Specification No.KBS 13.22.[Market Rate] | Each | 9500.0 | 9500.0 | 1.0 | False | None | None | False | None | False | 9500.0 | 0 |
3686273 | 135214 | None | code38 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover [Common SR Water Supply 2021-22 Vol:2 P.NO.158 I.No:16.9] | Each | 5617.62 | 5617.62 | 2.0 | False | None | None | False | None | False | 11235.24 | 0 |
3686274 | 135214 | None | code39 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 [Common SR Water Supply 2023-24 Vol:2 P.NO.113 I.No:10.1.7] | m | 423.33 | 423.33 | 30.0 | False | None | None | False | None | False | 12699.9 | 0 |
3686275 | 135214 | None | code40 | Supplying heavy gauge PVC conduit pipe 20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 1 I.No:1.1.1] | m | 69.0 | 69.0 | 21.14 | False | None | None | False | None | False | 1458.66 | 0 |
3686276 | 135214 | None | code41 | Supplying and fixing PVC/metal conduit 19/20 mm deep Junction box [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 1 I.No:1.5.1] | Each | 49.0 | 49.0 | 4.0 | False | None | None | False | None | False | 196.0 | 0 |
3686277 | 135214 | None | code42 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete 8" x 6" x 3" (203 x 152 x 76 mm) [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 1 I.No:1.6.4] | Each | 86.0 | 86.0 | 10.0 | False | None | None | False | None | False | 860.0 | 0 |
3686278 | 135214 | None | code43 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and atest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a Wood/PVC round block. complete for each outlet Short point upto 3m from tapping point to out let via switch [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 2 I.No:2.1.1] | Point | 285.0 | 285.0 | 5.0 | False | None | None | False | None | False | 1425.0 | 0 |
3686279 | 135214 | None | code44 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and atest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a Wood/PVC round block. complete for each outlet Long point above 6m upto 10m from tapping point to out let via switch [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 2 I.No:2.1.3] | Point | 570.0 | 570.0 | 2.0 | False | None | None | False | None | False | 1140.0 | 0 |
3686280 | 135214 | None | code45 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5Sqmm [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 5 I.No:2.3.3] | m | 42.0 | 42.0 | 45.0 | False | None | None | False | None | False | 1890.0 | 0 |
3686281 | 135214 | None | code46 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 1 to 2 Module [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 8 I.No:3.5.1] | Each | 137.0 | 137.0 | 10.0 | False | None | None | False | None | False | 1370.0 | 0 |
3686282 | 135214 | None | code47 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 9 I.No:3.6.3] | Each | 171.0 | 171.0 | 20.0 | False | None | None | False | None | False | 3420.0 | 0 |
3686283 | 135214 | None | code48 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator Two Module [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 9 I.No:3.6.4] | Each | 357.0 | 357.0 | 8.0 | False | None | None | False | None | False | 2856.0 | 0 |
3686284 | 135214 | None | code49 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A SP Switch [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 10 I.No:3.14.1] | No | 55.0 | 55.0 | 10.0 | False | None | None | False | None | False | 550.0 | 0 |
3686285 | 135214 | None | code50 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Two Way Switch [PWD SR 2023-24 Electrical SR Chapter-1 P.NO. 6 I.No:3.14.2] | No | 70.0 | 70.0 | 10.0 | False | None | None | False | None | False | 700.0 | 0 |
3686286 | 135214 | None | code51 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA [PWD SR 2023-24 Electrical SR Chapter-1 P.NO.21 I.No:5.46.6] | Each | 1195.0 | 1195.0 | 2.0 | False | None | None | False | None | False | 2390.0 | 0 |
3686287 | 135214 | None | code52 | Supplying & fixing retrofit type-PL- LED Lamp 8-9 W LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM80.The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. [PWD SR 2023-24 Electrical SR Chapter-1 P.NO.43 I.No:11.2.1] | Each | 623.0 | 623.0 | 3.0 | False | None | None | False | None | False | 1869.0 | 0 |
3686288 | 135214 | None | code53 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2 12 Way [PWD SR 2023-24 Electrical SR Chapter-1 P.NO.17 I.No:5.17.3] | Each | 15529.0 | 15529.0 | 1.0 | False | None | None | False | None | False | 15529.0 | 0 |
3686289 | 135214 | None | code54 | Providing main connection from pole PVC insulated sheathed steel wire cable in GI pipe as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit [Water Supply SR 2021-22 P.NO.164 I.No:43] | m | 82.4 | 82.4 | 10.0 | False | None | None | False | None | False | 824.0 | 0 |
3686290 | 135214 | None | code55 | Providing,Supplying and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work. 3.5x25 Sqm [Water Supply SR 2021-22 P.NO.164 I.No:43] | Each | 767.35 | 767.35 | 2.0 | False | None | None | False | None | False | 1534.7 | 0 |
3686291 | 135214 | None | code56 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia[Water Supply SR 2021-22 P.NO.164 I.No:44] | Job | 3862.5 | 3862.5 | 3.0 | False | None | None | False | None | False | 11587.5 | 0 |
3686292 | 135214 | None | code57 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. in all kinds of Soil depth Upto 1.50M [PWD SR 2023-24 Vol:3 P.NO.6 I.No:1.6.1 ] | Cum | 498.52 | 498.52 | 79.649 | False | None | None | False | None | False | 39706.61948 | 0 |
3686293 | 135214 | None | code58 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 90mm dia., 6 kg/sqcm & class 3 [PWD SR 2023-24 Vol:5 P.NO.113 I.No:10.1.6] | m | 302.82 | 302.82 | 177.0 | False | None | None | False | None | False | 53599.14 | 0 |
3686294 | 135214 | None | code59 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m.Including cost of all labour complete as per specifications [PWD SR 2023-24 Vol:1 P.NO.7 I.No:1.10] | Cum | 164.8 | 164.8 | 71.684 | False | None | None | False | None | False | 11813.5232 | 0 |