1722687086000 | 0 | None | None | Other Works | Construction of Toilets blocks in primary & highschool of boys and girls in Nivedita school, hosayellapur at ward no.16, zone.03, dharwad. | 843593.35 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3683629 | 135048 | None | 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m (PWD SR 2023-24 Vol No.01 P.No.08 SI No.1.14.1)
| Cum | 107.0 | 107.0 | 32.7 | False | None | None | False | None | False | 3498.9 | 0 | 3683630 | 135048 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (PWD SR 2023-24 Vol No.01 P.No.07 SI No.1.9)
| Cum | 279.0 | 279.0 | 23.57 | False | None | None | False | None | False | 6576.03 | 0 | 3683631 | 135048 | None | 2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 Vol No.01 P.No.15 SI No.2.1.3)
| Cum | 6288.0 | 6288.0 | 3.42 | False | None | None | False | None | False | 21504.96 | 0 | 3683632 | 135048 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD SR 2023-24 Vol No.01 P.No.16 SI No.2.5.1)
| Cum | 6962.0 | 6962.0 | 14.11 | False | None | None | False | None | False | 98233.82 | 0 | 3683633 | 135048 | None | 11 SI No.001 | Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding Percentage on finished rate of concrete per m3 Foundation upto Plinth Isolated 8% (PWD SR 2023-24 Vol No.01 P.No.111 SI No.001)
| Cum | 530.0 | 530.0 | 3.89 | False | None | None | False | None | False | 2061.7 | 0 | 3683634 | 135048 | None | 111 SI No.009 | Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding Percentage on finished rate of concrete per m3 RCC Columns / Shaft (Slip Centering) 70% (PWD SR 2023-24 Vol No.01 P.No.111 SI No.009)
| Cum | 4641.0 | 4641.0 | 1.1 | False | None | None | False | None | False | 5105.1 | 0 | 3683635 | 135048 | None | 111 SI No.002) | Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding Percentage on finished rate of concrete per m3 Plinth Beams of Buildings 50% (PWD SR 2023-24 Vol No.01 P.No.111 SI No.002)
| Cum | 3315.0 | 3315.0 | 2.6 | False | None | None | False | None | False | 8619.0 | 0 | 3683636 | 135048 | None | 112 SI No.14 | Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding Percentage on finished rate of concrete per m3RCC Beams, Lintels & Troughs of Aqueducts 60% (PWD SR 2023-24 Vol No.01 P.No.112 SI No.14)
| Cum | 3978.0 | 3978.0 | 2.6 | False | None | None | False | None | False | 10342.8 | 0 | 3683637 | 135048 | None | 112 SI No.15 | Addendum I Percentage Additionalities for Formwork, Centering & Scaffolding Percentage on finished rate of concrete per m3 RCC Roof Slabs 50% (PWD SR 2023-24 Vol No.01 P.No.112 SI No.15)
| Cum | 3315.0 | 3315.0 | 3.92 | False | None | None | False | None | False | 12994.8 | 0 | 3683638 | 135048 | None | 2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings(PWD SR 2023-24 Vol No.01 P.No.18 SI No.2.11a)
| Tonne | 93930.0 | 93930.0 | 1.1704 | False | None | None | False | None | False | 109935.672 | 0 | 3683639 | 135048 | None | 5.1.1 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)(PWD SR 2023-24 Vol No.02 P.No.09 SI No.5.1.1 )
| Cum | 5892.0 | 5892.0 | 5.14 | False | None | None | False | None | False | 30284.88 | 0 | 3683640 | 135048 | None | 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications.(PWD SR 2023-24 Vol No.02 P.No.17 SI No.6.32 )
| Sqm | 1376.0 | 1376.0 | 58.3 | False | None | None | False | None | False | 80220.8 | 0 | 3683641 | 135048 | None | 6.33 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD SR 2023-24 Vol No.02 P.No.17 SI No.6.33)
| Sqm | 1293.0 | 1293.0 | 19.0 | False | None | None | False | None | False | 24567.0 | 0 | 3683642 | 135048 | None | 8.4.1 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - etc., complete with all lead and lift, loading & unloading. And as directed by the Engineer-in-charge of the work.(PWD SR 2023-24 Vol No.02 P.No.41 SI No.8.4.1)
| Sqm | 339.0 | 339.0 | 26.99 | False | None | None | False | None | False | 9149.61 | 0 | 3683643 | 135048 | None | 8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(PWD SR 2023-24 Vol No.02 P.No.42 SI No.8.9)
| Sqm | 404.0 | 404.0 | 76.78 | False | None | None | False | None | False | 31019.12 | 0 | 3683644 | 135048 | None | 9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. (PWD SR 2023-24 Vol No.02 P.No.64 SI No.9.36)
| Sqm | 1733.0 | 1733.0 | 1.8 | False | None | None | False | None | False | 3119.4 | 0 | 3683645 | 135048 | None | 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (PWD SR 2023-24 Vol No.02 P.No.86 SI No.11.34A)
| Kg | 176.0 | 176.0 | 37.8 | False | None | None | False | None | False | 6652.8 | 0 | 3683646 | 135048 | None | 8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Vol No.02 P.No.42 SI No.8.7)
| Sqm | 384.0 | 384.0 | 127.18 | False | None | None | False | None | False | 48837.12 | 0 | 3683647 | 135048 | None | 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with
19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. (PWD SR 2023-24 Vol No.02 P.No.104 SI No.12.54)
| Sqm | 334.0 | 334.0 | 7.88 | False | None | None | False | None | False | 2631.92 | 0 | 3683648 | 135048 | None | 12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom
rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. do- with both side prelam (PWD SR 2023-24 Vol No.02 P.No.104 SI No.12.55.1)
| Sqm | 2484.0 | 2484.0 | 5.04 | False | None | None | False | None | False | 12519.36 | 0 | 3683649 | 135048 | None | 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Vol No.02 P.No.48 SI No.8.40)
| Sqm | 121.0 | 121.0 | 1.89 | False | None | None | False | None | False | 228.69 | 0 | 3683650 | 135048 | None | 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). (PWD SR 2023-24 Vol No.02 P.No.109 SI No.12.85)
| Sqm | 6005.0 | 6005.0 | 1.89 | False | None | None | False | None | False | 11349.45 | 0 | 3683651 | 135048 | None | 10.4 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete - etc., complete with all lead and lift, loading & unloading. And as directed by the Engineer-in-charge of the work.(PWD SR 2023-24 Vol No.02 P.No.71 SI No.10.14)
| Sqm | 1161.0 | 1161.0 | 129.84 | False | None | None | False | None | False | 150744.24 | 0 | 3683652 | 135048 | None | 9.9 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete - etc., complete with all lead and lift, loading & unloading. And as directed by the Engineer-in-charge of the work.(PWD SR 2023-24 Vol No.02 P.No.60 SI No9.9)
| Sqm | 1130.0 | 1130.0 | 26.99 | False | None | None | False | None | False | 30498.7 | 0 | 3683653 | 135048 | None | 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls over and including one coat of Special primer applied with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge - etc., complete with all lead and lift, loading & unloading. And as directed by the Engineer-in-charge of the work.(PWD SR 2023-24 Vol No.02 P.No.46 SI No8.33.1)
| Sqm | 166.0 | 166.0 | 118.78 | False | None | None | False | None | False | 19717.48 | 0 | 3683654 | 135048 | None | 13.31.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes(PWD SR 2023-24 Vol No.02 P.No.122 SI No.13.31.2)
| Sqm | 398.0 | 398.0 | 23.0 | False | None | None | False | None | False | 9154.0 | 0 | 3683655 | 135048 | None | 14.1.1 | Providing & fixing White vitreous china water closet squatting pan (Indiantype) along with "S" or "P" trap including dismantling of old WC seat and"S" or "P" trap at site complete with all operations including all necessarymaterials, labour and disposal of dismantled material i/c malba, allcomplete as per the direction of Engineer-in charge.Long pattern W.C Pan of size 580x440 mm (PWD SR 2023-24 Vol No.02 P.No.130 SI No.14.1.1)
| Each | 2931.0 | 2931.0 | 5.0 | False | None | None | False | None | False | 14655.0 | 0 | 3683656 | 135048 | None | 14.4.1f | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern - etc., complete with all lead and lift, loading & unloading. And as directed by the Engineer-in-charge of the work.(PWD SR 2023-24 Vol No.02 P.No.131 SI No14.4.1)
| Each | 4677.0 | 4677.0 | 3.0 | False | None | None | False | None | False | 14031.0 | 0 | 3683657 | 135048 | None | 14.7.4 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap - etc., complete with all lead and lift, loading & unloading. And as directed by the Engineer-in-charge of the work.(PWD SR 2023-24 Vol No.02 P.No.132 SI No.14.7.4)
| Each | 2462.0 | 2462.0 | 2.0 | False | None | None | False | None | False | 4924.0 | 0 | 3683658 | 135048 | None | 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(PWD SR 2023-24 Vol No.02 P.No.122 SI No.13.34)
| Ltr | 9.0 | 9.0 | 2000.0 | False | None | None | False | None | False | 18000.0 | 0 | 3683659 | 135048 | None | 13.17.1 | Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 g.(PWD SR 2023-24 Vol No.02 P.No.120 SI No.13.17.1)
| No | 166.0 | 166.0 | 15.0 | False | None | None | False | None | False | 2490.0 | 0 | 3683660 | 135048 | None | 13.50.5 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work.40 mm nominal dia Pipe (PWD SR 2023-24 Vol No.02 P.No.125 SI No.13.50.5)
| Rmtr | 319.0 | 319.0 | 30.0 | False | None | None | False | None | False | 9570.0 | 0 | 3683661 | 135048 | None | 1.2.1 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work.65 mm nominal dia Pipes (PWD SR 2023-24 P.No.125 SI No 1.2.1)
| Rmtr | 570.0 | 570.0 | 20.0 | False | None | None | False | None | False | 11400.0 | 0 | 3683662 | 135048 | None | 1.2.1 | Open Conduit System Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceilling ans RCC wall/stone structure or rawl plugs in case of bricks walls and cement plastering the damaged portation using heavy guage saddles at an intervak of 700mm using NF screws - etc., complete with all lead and lift, loading & unloading. And as directed by the Engineer-in-charge of the work.(Ele SR 2023-24 P.No.01 SI No.1.2.1)
| Rmtr | 68.0 | 68.0 | 30.0 | False | None | None | False | None | False | 2040.0 | 0 | 3683663 | 135048 | None | 2.1.2 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch. - etc., complete with all lead and lift, loading & unloading. And as directed by the Engineer-in-charge of the work.(Ele SR 2023-24 P.No.4 SI No.2.1.2)
| Rmtr | 389.0 | 389.0 | 9.0 | False | None | None | False | None | False | 3501.0 | 0 | 3683664 | 135048 | None | 3.1.2 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6Amps 2 Way. - etc., complete with all lead and lift, loading & unloading. And as directed by the Engineer-in-charge of the work.(Ele SR 2023-24 P.No.07 SI No.3.1.2)
| Each | 121.0 | 121.0 | 9.0 | False | None | None | False | None | False | 1089.0 | 0 | 3683665 | 135048 | None | 3.7 | Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts, 50Hz AC supply & completely wired on existing box. - etc., complete with all lead and lift, loading & unloading. And as directed by the Engineer-in-charge of the work.(Ele SR 2023-24 P.No.08 SI No.3.7) | Each | 748.0 | 748.0 | 1.0 | False | None | None | False | None | False | 748.0 | 0 | 3683666 | 135048 | None | 1.6.1 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.12""x12""x3"" (300 x 300 x 76 MM) - etc., complete with all lead and lift, loading & unloading. And as directed by the Engineer-in-charge of the work(Ele SR 2023-24 P.No.02 SI No.1.6.1) | Each | 112.0 | 112.0 | 4.0 | False | None | None | False | None | False | 448.0 | 0 | 3683667 | 135048 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. - etc., complete with all lead and lift, loading & unloading. And as directed by the Engineer-in-charge of the work.(Ele SR 2023-24 P.No.04 SI No.2.3.3 | Rmtr | 40.0 | 40.0 | 30.0 | False | None | None | False | None | False | 1200.0 | 0 | 3683668 | 135048 | None | 11.3.2 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. - etc., complete with all lead and lift, loading & unloading. And as directed by the Engineer-in-charge of the work(Ele SR 2023-24 P.No.42 SI No11.3.2)
| Each | 249.0 | 249.0 | 12.0 | False | None | None | False | None | False | 2988.0 | 0 | 3683669 | 135048 | None | 23.24 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.(Ele SR 2023-24 Vol No.02 P.No.01 SI No23.24) | No | 1281.0 | 1281.0 | 2.0 | False | None | None | False | None | False | 2562.0 | 0 | 3683670 | 135048 | None | 23.24 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.(Ele SR 2023-24 Vol No.02 P.No.137 SI No.14.40
| No | 399.0 | 399.0 | 2.0 | False | None | None | False | None | False | 798.0 | 0 | 3683671 | 135048 | None | 13.51 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 Coarse sand) with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay (non modular) bricks of class designation 3.5 (PWD SR 2023-24 Vol No.02 P.No.125 SI NO13.51)
| No | 1791.0 | 1791.0 | 2.0 | False | None | None | False | None | False | 3582.0 | 0 |
|