| 1722607849000 | 0 | None | None | Other Works | Development of park in skandapura Layout and construction of compound wall and other improvement works for Dr B R Ambedkar bhavana in sandur TMC Limits | 1438965.33 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3677986 | 134684 | None | P4A1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work..In all kinds of soils Depth upto 1.5 m (Vol-1 Page no: 5 item no:1.4.1) | Cum | 254.1 | 254.1 | 119.07 | False | None | None | False | None | False | 30255.687 | 0 | | 3677987 | 134684 | None | P4A2 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (Vol-2 Page no: 175 item no:17.1) | Cum | 1052.1 | 1052.1 | 37.04 | False | None | None | False | None | False | 38969.784 | 0 | | 3677988 | 134684 | None | P4A3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (Vol-1 Page no: 15 item no:2.1.2) | Cum | 5947.2 | 5947.2 | 4.704 | False | None | None | False | None | False | 27975.6288 | 0 | | 3677989 | 134684 | None | P4A4 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paidseparately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol-1 Page no:16 item no:2.4.2) | Cum | 6639.15 | 6639.15 | 21.13 | False | None | None | False | None | False | 140285.2395 | 0 | | 3677990 | 134684 | None | P4A5 | Rates of Formwork Shall be Added on percentage basis to finished concrete Item rate ForVarious Work Addendum I Percentage Additionalities for Formwork,Centering & Scaffolding Earth retaining structures | Cum | 531.13 | 531.13 | 2.97 | False | None | None | False | None | False | 1577.4561 | 0 | | 3677991 | 134684 | None | P4A6 | Rates of Formwork Shall be Added on percentage basis to finished concrete Item rate ForVarious Work Addendum I Percentage Additionalities for Formwork,Centering & Scaffolding Earth retaining structures | Cum | 3319.57 | 3319.57 | 13.23 | False | None | None | False | None | False | 43917.9111 | 0 | | 3677992 | 134684 | None | P4A7 | Rates of Formwork Shall be Added on percentage basis to finished concrete Item rate ForVarious Work Addendum I Percentage Additionalities for Formwork,Centering & Scaffolding Earth retaining structures | Cum | 4647.4 | 4647.4 | 4.92 | False | None | None | False | None | False | 22865.208 | 0 | | 3677993 | 134684 | None | P4A8 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (The laps and wastages shall not be measured separately) (Page no: 18 item no:2.11.a) | t | 82961.55 | 82961.55 | 1.65 | False | None | None | False | None | False | 136886.5575 | 0 | | 3677994 | 134684 | None | P4A9 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.s (Vol-II Page no: 45 item no:8.28) | Sqm | 93.45 | 93.45 | 102.9 | False | None | None | False | None | False | 9616.005 | 0 | | 3677995 | 134684 | None | P4A10 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Vol-II Page no: 83 item no:11.25.1) | Kg | 118.65 | 118.65 | 3308.31 | False | None | None | False | None | False | 392530.9815 | 0 | | 3677996 | 134684 | None | P4A11 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work..In all kinds of soils Depth upto 1.5 m (Vol-1 Page no: 5 item no:1.4.1) | Cum | 254.1 | 254.1 | 36.09 | False | None | None | False | None | False | 9170.469 | 0 | | 3677997 | 134684 | None | P4A12 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (Vol-2 Page no: 175 item no:17.1) | Cum | 1052.1 | 1052.1 | 22.76 | False | None | None | False | None | False | 23945.796 | 0 | | 3677998 | 134684 | None | P4B1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (Vol-1 Page no: 15 item no:2.1.2) | Cum | 5947.2 | 5947.2 | 2.23 | False | None | None | False | None | False | 13262.256 | 0 | | 3677999 | 134684 | None | P4B2 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paidseparately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol-1 Page no:16 item no:2.4.2) | Cum | 6639.15 | 6639.15 | 6.38 | False | None | None | False | None | False | 42357.777 | 0 | | 3678000 | 134684 | None | P4B3 | Rates of Formwork Shall be Added on percentage basis to finished concrete Item rate ForVarious Work Addendum I Percentage Additionalities for Formwork,Centering & Scaffolding Earth retaining structures | Cum | 531.13 | 531.13 | 1.41 | False | None | None | False | None | False | 748.8933 | 0 | | 3678001 | 134684 | None | P4B4 | Rates of Formwork Shall be Added on percentage basis to finished concrete Item rate ForVarious Work Addendum I Percentage Additionalities for Formwork,Centering & Scaffolding Earth retaining structures | Cum | 3319.57 | 3319.57 | 3.2085 | False | None | None | False | None | False | 10650.840345 | 0 | | 3678002 | 134684 | None | P4B5 | Rates of Formwork Shall be Added on percentage basis to finished concrete Item rate ForVarious Work Addendum I Percentage Additionalities for Formwork,Centering & Scaffolding Earth retaining structures | Cum | 4647.4 | 4647.4 | 1.76 | False | None | None | False | None | False | 8179.424 | 0 | | 3678003 | 134684 | None | P4B6 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (The laps and wastages shall not be measured separately) (Page no: 18 item no:2.11.a) | t | 82961.55 | 82961.55 | 0.5 | False | None | None | False | None | False | 41480.775 | 0 | | 3678004 | 134684 | None | P4B7 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
m2 1,231.00 (Vol-II Page no: 17 item no:6.33) | Sqm | 1292.55 | 1292.55 | 75.788 | False | None | None | False | None | False | 97959.7794 | 0 | | 3678005 | 134684 | None | P4B8 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge PWD CSR 2023-24, Vol-II, P. No. 42, I. No. 8.7 | Sqm | 384.3 | 384.3 | 195.3 | False | None | None | False | None | False | 75053.79 | 0 | | 3678006 | 134684 | None | P4B9 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.s (Vol-II Page no: 45 item no:8.28) | Sqm | 93.45 | 93.45 | 195.3 | False | None | None | False | None | False | 18250.785 | 0 | | 3678007 | 134684 | None | P4B10 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Vol-II Page no: 83 item no:11.25.1) | Kg | 118.65 | 118.65 | 1237.5 | False | None | None | False | None | False | 146829.375 | 0 | | 3678008 | 134684 | None | P4B11 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2) | Sqm | 596.4 | 596.4 | 82.5 | False | None | None | False | None | False | 49203.0 | 0 | | 3678009 | 134684 | None | P4B12 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete,Gutter (600 mm over all girth) (Item No. 7.39.6, Page No. 27, Vol.2) | m | 1127.7 | 1127.7 | 40.0 | False | None | None | False | None | False | 45108.0 | 0 | | 3678010 | 134684 | None | P4B13 | Providing & fixing flat iron brackets 50x3 mm size with necessary bolts, nuts and washers etc. for fixing G.S. sheets gutters with purlins. (Item No. 7.13, Page No. 22, Vol.2) | m | 77.7 | 77.7 | 20.0 | False | None | None | False | None | False | 1554.0 | 0 | | 3678011 | 134684 | None | P4B14 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuserwith Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @Lumen Maintenance of 70percentage , maximum light intensity shouldbe between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistanceof complete luminaire greater than IK08. Power Factor greater than 0.9 withmains, Surge Protection Min 5KV along with Over voltage/Overload, short circuit/ missnwiring protection. Compatiblefor pole mouting with outer dia of 40mm to 50mm. UniversalVoltage driver to operate wide voltage range from 100V to270V 50/60Hz application. Compliance to IS 10322/IEC60598, LM 79 & LM 80 Adherence with RoHS. UL approvedMCPCB. Top access street light with single screw to ensureease of maintenance at the sight site location with minimizedminimal tools. LED Light fixture with ........W System Powerconsumption. LED Efficiency greater than130lm/w, nominal CRI greater than 75.Luminaire manufacturer should have in house facilityaccredited by NABL/CPRI & any Government certifiedagency & Design & Development facility certified by ISO9001:2008 . Housing with supplier word mark /name shallbe Engraved / Embossing on the die cast housing/ Bodypart. Warranty of 2 Years against any manufacturing defectworking under standard electrical onditions as mentionedabove should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source.(PWD ELE SR 2023-24 Page no: 46 item no:11.8.4 ) | Set | 9303.0 | 9303.0 | 1.0 | False | None | None | False | None | False | 9303.0 | 0 | | 3678012 | 134684 | None | P4B15 | Supplying and Fixing of........mm dia class A GI pipe bracket up to 2 Mtrs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts fluorescent tube treet light fitting of all capacities to GI or CI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires.Using 25mm dia .I.Pipe (Page no:56 item no:13.1.1) | Each | 1026.9 | 1026.9 | 1.0 | False | None | None | False | None | False | 1026.9 | 0 |
|