createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1722675354866
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd21600.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose20-08-2024 16:30:00
tenderQueryClose19-08-2024 16:00:00
technicalBidOpen22-08-2024 11:00:00
publishedDate03-08-2024 18:47:16
publishedByPostTP_CO_KKW
publishedByUserKPE17481 - INDU SHEVANTA SHINGE
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonG R Pattar
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber8310807091
mobileNumber8310807091
tenderSupplierListNone
tenderSchedule
createdTs1722675354902
version8
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT22263
titleConstruction of Security Room, and Provide Electric at Kankanawadi SWM Site.
descriptionConstruction of Security Room, and Provide Electric at Kankanawadi SWM Site.
categoryWORKS
categoryTextWorks
ecv863013.57
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2514
locationNameDMA Town Panchayat Kankanwadi
provisionalAmount863085.0
groupOverheadTotal136606.24
fileNumberSBM2/P4
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17226753550001NoneNoneBuildingsConstruction of Security Room at Kankanawadi SWM Site.707642.33
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3681013134863Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 mCum107.1107.119.936FalseNoneNoneFalseNoneFalse2135.14560
3681014134863Nonecode025.1 Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) upto plinth level with: 5.1.1 Cement mortar 1:6 (1 cement: 6 coarse sand)Cum5891.555891.5518.503FalseNoneNoneFalseNoneFalse109011.349650
3681015134863Nonecode031.9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.38.4562FalseNoneNoneFalseNoneFalse2361.816660
3681016134863Nonecode042.2 Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.2.1.1 m0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum6288.456288.453.101FalseNoneNoneFalseNoneFalse19500.483450
3681017134863Nonecode05Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) 2.1.3 Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6601.356601.355.076FalseNoneNoneFalseNoneFalse33508.45260
3681018134863Nonecode06Addendum I-Additionalities for formwork, Centering & Scaffolding " For Foundation upto Plinth (a) Isolated " at 8%Cum532.22532.225.076FalseNoneNoneFalseNoneFalse2701.548720
3681019134863Nonecode072.3 Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 m5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6804.06804.02.2218FalseNoneNoneFalseNoneFalse15117.12720
3681020134863Nonecode08Appendix I-Additionalities for formwork, Centering & Scaffolding " For Columns " at 70%Cum4386.484386.480.9522FalseNoneNoneFalseNoneFalse4176.8062560
3681021134863Nonecode09Appendix I-Additionalities for formwork, Centering & Scaffolding " For Plinth Beams of Buildings " at 50%Cum3133.23133.21.2696FalseNoneNoneFalseNoneFalse3977.910720
3681022134863Nonecode102.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 m5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.154.0911FalseNoneNoneFalseNoneFalse29395.1671650
3681023134863Nonecode11Addendum I-Additionalities for formwork, Centering & Scaffolding " For Chejjas, Canopy & Other Architectural projections of monor sections " at 45%Cum3233.323233.320.6648FalseNoneNoneFalseNoneFalse2149.5111360
3681024134863Nonecode12Addendum I-Additionalities for formwork, Centering & Scaffolding " For Roof slab of Buildings " at 50%Cum3592.583592.582.1567FalseNoneNoneFalseNoneFalse7748.1172860
3681025134863Nonecode136.8 Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8367.458367.4512.359FalseNoneNoneFalseNoneFalse103413.314550
3681026134863Nonecode14Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.t93929.8593929.851.366FalseNoneNoneFalseNoneFalse128308.17510
3681027134863Nonecode1512.13.1 Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.m103755.75103755.750.066FalseNoneNoneFalseNoneFalse6847.87950
3681028134863Nonecode1612.15 Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )m7241.857241.852.52FalseNoneNoneFalseNoneFalse18249.4620
3681029134863Nonecode1711.34B Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Kg192.15192.15120.96FalseNoneNoneFalseNoneFalse23242.4640
3681030134863Nonecode1812.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7070.77070.75.76FalseNoneNoneFalseNoneFalse40727.2320
3681031134863Nonecode198.1.1 Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.m267.75267.7563.05FalseNoneNoneFalseNoneFalse16881.63750
3681032134863Nonecode208.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.m389.55389.55178.274FalseNoneNoneFalseNoneFalse69446.63670
3681033134863Nonecode219.12 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m including grouting the joints with white cement and matching pigments etc., complete. 9.12.2 Size of Tile 600x600 mmm1202.251202.2528.5FalseNoneNoneFalseNoneFalse34264.1250
3681034134863Nonecode228.30 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.m182.7182.7178.274FalseNoneNoneFalseNoneFalse32570.65980
3681035134863Nonecode2312.54 Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in- charge.m340.59340.595.6FalseNoneNoneFalseNoneFalse1907.3040
17226753550001NoneNoneBuildingsSupply Electric at Kankanawadi SWM Site Security Room.18765.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3681036134864Nonecode01Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm 25mm etc. as required.Mtr35.035.050.0FalseNoneNoneFalseNoneFalse1750.00
3681037134864Nonecode02Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood,fter due groove cutting, finishing with necessary cement plastering complete. 4"x4"x3" ( 101x101x76mm)Each74.074.04.0FalseNoneNoneFalseNoneFalse296.00
3681038134864Nonecode03I. Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Using class A Materials b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint394.0394.01.0FalseNoneNoneFalseNoneFalse394.00
3681039134864Nonecode04I. Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Using class A Materials b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint570.0570.01.0FalseNoneNoneFalseNoneFalse570.00
3681040134864Nonecode05Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in pen or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5 sqmmMtr26.026.060.0FalseNoneNoneFalseNoneFalse1560.00
3681041134864Nonecode06Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in pen or concealed system of wiring with specified IS-694:confirming to latest amendments 2.5 sqmmMtr42.042.020.0FalseNoneNoneFalseNoneFalse840.00
3681042134864Nonecode07Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in 2.5 sqmm Brick/Stone/C.C wall 1-3WayEach138.0138.01.0FalseNoneNoneFalseNoneFalse138.00
3681043134864Nonecode08Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in 2.5 sqmm Brick/Stone/C.C wall 8WayEach261.0261.01.0FalseNoneNoneFalseNoneFalse261.00
3681044134864Nonecode09Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. Group-A 1 to 3 ModuleEach161.0161.01.0FalseNoneNoneFalseNoneFalse161.00
3681045134864Nonecode10Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. Group-A 8MouduleEach284.0284.01.0FalseNoneNoneFalseNoneFalse284.00
3681046134864Nonecode11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 6Amps one way.Each102.0102.01.0FalseNoneNoneFalseNoneFalse102.00
3681047134864Nonecode12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials Stepped Fan Regulator.Each357.0357.01.0FalseNoneNoneFalseNoneFalse357.00
3681048134864Nonecode13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 16Amps one way switchEach180.0180.01.0FalseNoneNoneFalseNoneFalse180.00
3681049134864Nonecode14Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 32Amps DP switchEach326.0326.01.0FalseNoneNoneFalseNoneFalse326.00
3681050134864Nonecode15Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 6/16Amps universal socketEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3681051134864Nonecode16Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 6Amps 3way socket.Each171.0171.03.0FalseNoneNoneFalseNoneFalse513.00
3681052134864Nonecode17Supplying of ..feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI less than 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. years Warranty against any manufacturing defect working under standard electrical condition.12.3.2 LED light fitting 1 x 4'- 20/22 w Each LED light fitting 1 x 4'- 20/22 w EachEach690.0690.06.0FalseNoneNoneFalseNoneFalse4140.00
3681053134864Nonecode18Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32AmpsEach241.0241.01.0FalseNoneNoneFalseNoneFalse241.00
3681054134864Nonecode19Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. a) 6-32Amps SPEach415.0415.01.0FalseNoneNoneFalseNoneFalse415.00
3681055134864Nonecode20Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. Group 'A' 6-32 Amps DPEach739.0739.01.0FalseNoneNoneFalseNoneFalse739.00
3681056134864Nonecode21Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door a) 4Way sp &NEach1524.01524.01.0FalseNoneNoneFalseNoneFalse1524.00
3681057134864Nonecode22Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system and as per technical data approved. 48" Sweep (1200mm) Regular modelEach2984.02984.01.0FalseNoneNoneFalseNoneFalse2984.00
3681058134864Nonecode23Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 8"x6"1.5"Each87.087.01.0FalseNoneNoneFalseNoneFalse87.00
3681059134864Nonecode24Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 12"x12"2"Each162.0162.01.0FalseNoneNoneFalseNoneFalse162.00
3681060134864Nonecode25Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each315.0315.01.0FalseNoneNoneFalseNoneFalse315.00
3681061134864Nonecode26Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 20mmMtr19.019.010.0FalseNoneNoneFalseNoneFalse190.00
17226771360000NoneNoneBuildingsConstruction of Security Room, and Provide Electric at Kankanawadi SWM Site.726407.33
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3681336134881Nonecode01Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm 25mm etc. as required.Mtr35.035.050.0FalseNoneNoneFalseNoneFalse1750.00
3681313134881Nonecode01Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 mCum107.1107.119.936FalseNoneNoneFalseNoneFalse2135.14560
3681337134881Nonecode02Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood,fter due groove cutting, finishing with necessary cement plastering complete. 4"x4"x3" ( 101x101x76mm)Each74.074.04.0FalseNoneNoneFalseNoneFalse296.00
3681314134881Nonecode025.1 Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) upto plinth level with: 5.1.1 Cement mortar 1:6 (1 cement: 6 coarse sand)Cum5891.555891.5518.503FalseNoneNoneFalseNoneFalse109011.349650
3681315134881Nonecode031.9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.38.4562FalseNoneNoneFalseNoneFalse2361.816660
3681338134881Nonecode03I. Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Using class A Materials b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchPoint394.0394.01.0FalseNoneNoneFalseNoneFalse394.00
3681316134881Nonecode042.2 Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.2.1.1 m0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Cum6288.456288.453.101FalseNoneNoneFalseNoneFalse19500.483450
3681339134881Nonecode04I. Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Using class A Materials b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switchPoint570.0570.01.0FalseNoneNoneFalseNoneFalse570.00
3681317134881Nonecode05Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) 2.1.3 Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6601.356601.355.076FalseNoneNoneFalseNoneFalse33508.45260
3681340134881Nonecode05Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in pen or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5 sqmmMtr26.026.060.0FalseNoneNoneFalseNoneFalse1560.00
3681318134881Nonecode06Addendum I-Additionalities for formwork, Centering & Scaffolding " For Foundation upto Plinth (a) Isolated " at 8%Cum532.22532.225.076FalseNoneNoneFalseNoneFalse2701.548720
3681341134881Nonecode06Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in pen or concealed system of wiring with specified IS-694:confirming to latest amendments 2.5 sqmmMtr42.042.020.0FalseNoneNoneFalseNoneFalse840.00
3681342134881Nonecode07Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in 2.5 sqmm Brick/Stone/C.C wall 1-3WayEach138.0138.01.0FalseNoneNoneFalseNoneFalse138.00
3681319134881Nonecode072.3 Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 m5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6804.06804.02.2218FalseNoneNoneFalseNoneFalse15117.12720
3681320134881Nonecode08Appendix I-Additionalities for formwork, Centering & Scaffolding " For Columns " at 70%Cum4386.484386.480.9522FalseNoneNoneFalseNoneFalse4176.8062560
3681343134881Nonecode08Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in 2.5 sqmm Brick/Stone/C.C wall 8WayEach261.0261.01.0FalseNoneNoneFalseNoneFalse261.00
3681321134881Nonecode09Appendix I-Additionalities for formwork, Centering & Scaffolding " For Plinth Beams of Buildings " at 50%Cum3133.23133.21.2696FalseNoneNoneFalseNoneFalse3977.910720
3681344134881Nonecode09Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. Group-A 1 to 3 ModuleEach161.0161.01.0FalseNoneNoneFalseNoneFalse161.00
3681322134881Nonecode102.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 m5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7185.157185.154.0911FalseNoneNoneFalseNoneFalse29395.1671650
3681345134881Nonecode10Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. Group-A 8MouduleEach284.0284.01.0FalseNoneNoneFalseNoneFalse284.00
3681323134881Nonecode11Addendum I-Additionalities for formwork, Centering & Scaffolding " For Chejjas, Canopy & Other Architectural projections of monor sections " at 45%Cum3233.323233.320.6648FalseNoneNoneFalseNoneFalse2149.5111360
3681346134881Nonecode11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 6Amps one way.Each102.0102.01.0FalseNoneNoneFalseNoneFalse102.00
3681324134881Nonecode12Addendum I-Additionalities for formwork, Centering & Scaffolding " For Roof slab of Buildings " at 50%Cum3592.583592.582.1567FalseNoneNoneFalseNoneFalse7748.1172860
3681347134881Nonecode12Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials Stepped Fan Regulator.Each357.0357.01.0FalseNoneNoneFalseNoneFalse357.00
3681325134881Nonecode136.8 Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8367.458367.4512.359FalseNoneNoneFalseNoneFalse103413.314550
3681348134881Nonecode13Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 16Amps one way switchEach180.0180.01.0FalseNoneNoneFalseNoneFalse180.00
3681326134881Nonecode14Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.t93929.8593929.851.366FalseNoneNoneFalseNoneFalse128308.17510
3681349134881Nonecode14Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 32Amps DP switchEach326.0326.01.0FalseNoneNoneFalseNoneFalse326.00
3681327134881Nonecode1512.13.1 Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.m103755.75103755.750.066FalseNoneNoneFalseNoneFalse6847.87950
3681350134881Nonecode15Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 6/16Amps universal socketEach236.0236.01.0FalseNoneNoneFalseNoneFalse236.00
3681328134881Nonecode1612.15 Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )m7241.857241.852.52FalseNoneNoneFalseNoneFalse18249.4620
3681351134881Nonecode16Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Using Group "A" materials 6Amps 3way socket.Each171.0171.03.0FalseNoneNoneFalseNoneFalse513.00
3681329134881Nonecode1711.34B Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Kg192.15192.15120.96FalseNoneNoneFalseNoneFalse23242.4640
3681352134881Nonecode17Supplying of ..feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI less than 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. years Warranty against any manufacturing defect working under standard electrical condition.12.3.2 LED light fitting 1 x 4'- 20/22 w Each LED light fitting 1 x 4'- 20/22 w EachEach690.0690.06.0FalseNoneNoneFalseNoneFalse4140.00
3681330134881Nonecode1812.90 Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7070.77070.75.76FalseNoneNoneFalseNoneFalse40727.2320
3681353134881Nonecode18Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32AmpsEach241.0241.01.0FalseNoneNoneFalseNoneFalse241.00
3681354134881Nonecode19Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. a) 6-32Amps SPEach415.0415.01.0FalseNoneNoneFalseNoneFalse415.00
3681331134881Nonecode198.1.1 Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.m267.75267.7563.05FalseNoneNoneFalseNoneFalse16881.63750
3681332134881Nonecode208.8 Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.m389.55389.55178.274FalseNoneNoneFalseNoneFalse69446.63670
3681355134881Nonecode20Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. Group 'A' 6-32 Amps DPEach739.0739.01.0FalseNoneNoneFalseNoneFalse739.00
3681333134881Nonecode219.12 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m including grouting the joints with white cement and matching pigments etc., complete. 9.12.2 Size of Tile 600x600 mmm1202.251202.2528.5FalseNoneNoneFalseNoneFalse34264.1250
3681356134881Nonecode21Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. II - Double Door a) 4Way sp &NEach1524.01524.01.0FalseNoneNoneFalseNoneFalse1524.00
3681334134881Nonecode228.30 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.m182.7182.7178.274FalseNoneNoneFalseNoneFalse32570.65980
3681357134881Nonecode22Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system and as per technical data approved. 48" Sweep (1200mm) Regular modelEach2984.02984.01.0FalseNoneNoneFalseNoneFalse2984.00
3681335134881Nonecode2312.54 Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in- charge.m340.59340.595.6FalseNoneNoneFalseNoneFalse1907.3040
3681358134881Nonecode23Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 8"x6"1.5"Each87.087.01.0FalseNoneNoneFalseNoneFalse87.00
3681359134881Nonecode24Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 12"x12"2"Each162.0162.01.0FalseNoneNoneFalseNoneFalse162.00
3681360134881Nonecode25Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each315.0315.01.0FalseNoneNoneFalseNoneFalse315.00
3681361134881Nonecode26Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely 20mmMtr19.019.010.0FalseNoneNoneFalseNoneFalse190.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17226753560001NoneNoneELIGIBILITYAll conditions as per KW-1, KW-2, or KW-3 bidders required to read the document.None
17226753560000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17226753560000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17226753560000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17226753560000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSimilar nature of work donePast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTender Difference amount FDR Scan copies mustFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Tender Difference amount FDR Scan copies must
NoneNoneNoneNoneLiquid Assets And Availability of credit facility.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAnnual Turnover CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNonePWD/ZP Registration certificateOthersPWD/ZP Registration certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Company Registration CertificateFalseTechnical Bid
Liquid Assets And Availability of credit facilityTrueTechnical Bid
Contractor Registration CertificateTrueTechnical Bid
work done cost of 80 Percent of Estimate AmountTrueTechnical Bid
Similar nature of work done.TrueTechnical Bid
Annual Turnover Certificate.TrueTechnical Bid
Tender Difference amount FDR Scan copies mustTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsBelagaviBelagaviBelgaumRAIBAG (SC)KankanawadiNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone