1722681450000 | 0 | None | None | Water supply/sewage lines | Work of Providing & Laying of 300 mm dia RCC NP3pipe line and construction of Pre-cast RCC Machinehole in Kengal Hanumanthaiah road from Siddaiah road to lalbagh east gate as BBMP proposed Comperhensive development of White toppimg of K H Road (mission to Lalbagh east gate) Under GOK Grants under V V Puram service station of AEESW-2 sub division | 1634594.69 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3682386 | 134946 | None | code01 | dismantling of Flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately By Mechanical Means for Bituminous course | Cum | 322.0 | 322.0 | 82.63 | False | None | None | False | None | False | 26606.86 | 0 | 3682387 | 134946 | None | code02 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m | Cum | 262.0 | 262.0 | 323.75 | False | None | None | False | None | False | 84822.5 | 0 | 3682388 | 134946 | None | code03 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils1.5 to 3 mtr depth | Cum | 331.0 | 331.0 | 17.53 | False | None | None | False | None | False | 5802.43 | 0 | 3682389 | 134946 | None | code04 | Providing S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey 300mm dia RCC NP3 class | Mtr | 1332.0 | 1332.0 | 316.8 | False | None | None | False | None | False | 421977.6 | 0 | 3682390 | 134946 | None | code05 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications etc. with | Cum | 160.0 | 160.0 | 222.17 | False | None | None | False | None | False | 35547.2 | 0 | 3682391 | 134946 | None | code06 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work | Cum | 85.0 | 85.0 | 22.38 | False | None | None | False | None | False | 1902.3 | 0 | 3682392 | 134946 | None | code07 | Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thicknessas in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia 1.3 mtr depth SFRC & Cover | Nos | 49213.0 | 49213.0 | 5.0 | False | None | None | False | None | False | 246065.0 | 0 | 3682393 | 134946 | None | code08 | For Every 0.1m Additional from 1 m to 2 m depth | Nos | 1750.0 | 1750.0 | 20.0 | False | None | None | False | None | False | 35000.0 | 0 | 3682394 | 134946 | None | code09 | Machinehole constructing pre-cast RCC machinehole 1.2m internal dia 1.6 mtr depth & SFRC cover & frame | Nos | 54704.0 | 54704.0 | 6.0 | False | None | None | False | None | False | 328224.0 | 0 | 3682395 | 134946 | None | code10 | Dismantling the damaged or collapsed Machinehole ,conical in shape, and reconstructing the same for the samedimensions, with machine made wire cut brick in CM 1:4 with ordinary portland cement etc. as per design and specifications. The existing ring, cover and CC beeding to be used for 1 mtr depth | Nos | 15574.0 | 15574.0 | 1.0 | False | None | None | False | None | False | 15574.0 | 0 | 3682396 | 134946 | None | code11 | Providing, laying, spreading and compacting 200 mm graded stone aggregate to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers in sub base/ base course on well prepared surface and compacting with vibratory roller/ tamper/plate vibrator to achive the desired density complete as per Specifications. | Cum | 2559.0 | 2559.0 | 79.2 | False | None | None | False | None | False | 202672.8 | 0 | 3682397 | 134946 | None | code12 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc complete for PVC pipes 110mm dia., 6 kg/sqcm and class 3. | Mtr | 411.0 | 411.0 | 500.0 | False | None | None | False | None | False | 205500.0 | 0 | 3682398 | 134946 | None | code13 | Providing, filling and laying of sand bags filled with sand / clay for diversion of sewage during execution of work. | Nos | 64.0 | 64.0 | 50.0 | False | None | None | False | None | False | 3200.0 | 0 | 3682399 | 134946 | None | code14 | Dewatering the sewage / storm water by using reqired HP submersible pump for the diversion of storm / sewage during the execution of work. Considering for one Pump.5HP Pump. | hr | 310.0 | 310.0 | 70.0 | False | None | None | False | None | False | 21700.0 | 0 |
|