1722682201000 | 0 | None | None | Buildings | Construction of Govt. lower primary school building at Somerahalli village in Hiriyur Taluk, Chitradurga District (SC cataogry) | 4197980.05 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3682428 | 134952 | None | code01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.(P.NO 8.I.NO 1.12 PWDCSR 2023-24 Volme I ) | Cum | 95.0 | 95.0 | 48.0 | False | None | None | False | None | False | 4560.0 | 0 | 3682429 | 134952 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1 In all kinds of soils Depth upto 3 m(P.NO 8.I.NO 1.14.1 PWDCSR 2023-24 Volme I ) | Cum | 102.0 | 102.0 | 143.73 | False | None | None | False | None | False | 14660.46 | 0 | 3682430 | 134952 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement &formwork shall be paid separately Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarseaggregates (P.NO 15.I.NO 2.1.3 PWDCSR2023-24 Volme I ) | Cum | 5989.0 | 5989.0 | 42.53 | False | None | None | False | None | False | 254712.17 | 0 | 3682431 | 134952 | None | code04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery,curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.NO 15.I.NO 2.2.1 PWDCSR 2023-24 Volme I | Cum | 6418.44 | 6418.44 | 21.17 | False | None | None | False | None | False | 135878.3748 | 0 | 3682432 | 134952 | None | code05 | Providing Coursed rubble masonry (second sort) with hard stone infoundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(P.NO.9.I.NO 5.3 PWD SR 2023-24 Volme II) | Cum | 6205.0 | 6205.0 | 43.37 | False | None | None | False | None | False | 269110.85 | 0 | 3682433 | 134952 | None | code06 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(P.NO.9.I.NO 5.4 PWD SR 2023-24 Volme II) | Cum | 6389.0 | 6389.0 | 20.19 | False | None | None | False | None | False | 128993.91 | 0 | 3682434 | 134952 | None | code07 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.NO 16.I.NO 2.3.1 PWDCSR 2023-24 Volme I) for Coloum | Cum | 10749.1 | 10749.1 | 0.78 | False | None | None | False | None | False | 8384.298 | 0 | 3682435 | 134952 | None | code08 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, costof all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.NO 16.I.NO 2.3.1 PWDCSR 2023-24 Volme I) for P beam | Cum | 9484.5 | 9484.5 | 4.44 | False | None | None | False | None | False | 42111.18 | 0 | 3682436 | 134952 | None | code09 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge | Sqm | 266.0 | 266.0 | 143.73 | False | None | None | False | None | False | 38232.18 | 0 | 3682437 | 134952 | None | code10 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, \providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..: (P.NO.41.I.NO.8.3.1 PWD SR 2023-24 Volme II) | Sqm | 354.0 | 354.0 | 1265.56 | False | None | None | False | None | False | 448008.24 | 0 | 3682438 | 134952 | None | code11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings (Volume-i) (P.No.18, I.No.2.11.a) PWD SR 2023-24 | Tonne | 89457.0 | 89457.0 | 5.68 | False | None | None | False | None | False | 508115.76 | 0 | 3682439 | 134952 | None | code12 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(P.No 14.I.No 6.8 Common SR 2023-24 Vol -II) | Cum | 7969.0 | 7969.0 | 59.13 | False | None | None | False | None | False | 471206.97 | 0 | 3682440 | 134952 | None | code13 | Providing and laying in position plain cement concrete for levellingcourse for all works in foundation. The granite/trap/basalt crushedgraded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost ofall materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formworkshall be paid separately )Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (P.NO 15.I.NO 2.1.4 PWDCSR 2023-24 Volme I) | Cum | 6217.0 | 6217.0 | 7.71 | False | None | None | False | None | False | 47933.07 | 0 | 3682441 | 134952 | None | code14 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(P.NO 17.I.NO 2.5.1 PWDCSR 2023-24 Volme I) for Coloum | Cum | 11271.0 | 11271.0 | 7.34 | False | None | None | False | None | False | 82729.14 | 0 | 3682442 | 134952 | None | code15 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(P.NO 17.I.NO 2.5.1 PWDCSR 2023-24 Volme I) for Lintel and Roof beam | Cum | 10608.0 | 10608.0 | 12.21 | False | None | None | False | None | False | 129523.68 | 0 | 3682443 | 134952 | None | code16 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(P.NO 17.I.NO 2.5.1 PWDCSR 2023-24 Volme I) for Roof slab | Cum | 9273.0 | 9273.0 | 20.15 | False | None | None | False | None | False | 186850.95 | 0 | 3682444 | 134952 | None | code17 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(P.NO 17.I.NO 2.5.1 PWDCSR 2023-24 Volme I) for Chejja | Cum | 9613.5 | 9613.5 | 0.41 | False | None | None | False | None | False | 3941.535 | 0 | 3682445 | 134952 | None | code18 | Providing and fixing pressed steel door frames conforming toIS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical (P.NO.78.I.NO.11.14.1.1 PWD SR 2023-24 Volme II) | Mtr | 470.0 | 470.0 | 79.0 | False | None | None | False | None | False | 37130.0 | 0 | 3682446 | 134952 | None | code19 | Providing and fixing 1mm thick M.S. sheet door with frame of40x40x6 mm angle iron and 3 mm M.S. gusset plates at thejunctions and corners, all necessary fittings complete, includingapplying a priming coat of approved steel primer.Using M.S. angels40x40x6 mm for diagonal braces including cost of materials, labour,usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.NO.75 .I.NO.11.5.1 PWD SR 2023-24 Volme II) | Kg | 4478.0 | 4478.0 | 40.59 | False | None | None | False | None | False | 181762.02 | 0 | 3682447 | 134952 | None | code20 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.(P.NO.85.I.NO.11.34.A PWD SR 2023-24 Volme II) | Sqm | 168.0 | 168.0 | 627.48 | False | None | None | False | None | False | 105416.64 | 0 | 3682448 | 134952 | None | code21 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge .Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.(P.NO.63.I.NO.9.23 PWD SR 2023-24 Volme II) | Cum | 2466.0 | 2466.0 | 186.65 | False | None | None | False | None | False | 460278.9 | 0 | 3682449 | 134952 | None | code22 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating onNew terrace/ Chajjas/ Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greaterthan 400% and tensile strength greater than 2MPa as per ASTM D412.The waterproofing membrane to be applied in 2coats @ 1.6kg per m2to achieve final DFT (dry film thickness) of 1mm including prime coat ofepoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment ofconstruction joints completely as per specification & with a 10 yearswarranty on product & work from certified manufacturers as per the direction of the Engineer In charge. (PWD 2023-24,P-133 It 15.1) | Sqm | 817.0 | 817.0 | 158.39 | False | None | None | False | None | False | 129404.63 | 0 | 3682450 | 134952 | None | code23 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust,mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.NO.45.I.NO.8.25 PWD SR 2023-24 Volme II) | Sqm | 137.0 | 137.0 | 465.9 | False | None | None | False | None | False | 63828.3 | 0 | 3682451 | 134952 | None | code24 | Finishing walls with 100% Premium acrylic emulsion paint having VOCless than 50 gm/litre and UV resistance as per IS 15489:2004,Alkali & fungal resistance, dirt resistance exterior paint of requiredshade (Company Depot Tinted) with silicon additives, New work(Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat ofexterior primer applied @ 0.90 litre/10 m² with paint of approved qualityto give an even shade, after thoroughly brooming the surface to removeall dirt, dust, mortar drops and foreign matter including preparing thesurface even and sand paper smooth, cost of materials, labour completeas per specifications and as per directions of Engineer-in-charge.(Volume-ii) (P.No.46, I.No.8.32) PWD SR 2022 | Sqm | 156.0 | 156.0 | 549.53 | False | None | None | False | None | False | 85726.68 | 0 | 3682452 | 134952 | None | code25 | Painting Steel work with Deluxe Multi Surface Paint to give an evenshade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primerapplied @ 0.80 ltr/10 m² of approved brand and manufacture includingpreparing the surface after thorougly cleaning oil, grease, dirt and foreignmatter, cost of materials, labour complete as per specifications and asper directions of Engineer-in-charge.(Volume-ii) (P.No.47, I.No.8.33.3) PWD SR 2023-24 | Sqm | 106.0 | 106.0 | 71.82 | False | None | None | False | None | False | 7612.92 | 0 | 3682453 | 134952 | None | code26 | Providing and fixing hand rail of approved size by welding etc.to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. E.R.W. tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge.(P.NO.82.I.NO.11.26.2 PWD SR 2023-24 Volme II) | Sqm | 130.0 | 130.0 | 488.0 | False | None | None | False | None | False | 63440.0 | 0 | 3682454 | 134952 | None | code27 | Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.complete. (P.NO.55. I.NO.8.84 PWD SR 2023-24 Volme II. | Each | 475.0 | 475.0 | 5.0 | False | None | None | False | None | False | 2375.0 | 0 | 3682455 | 134952 | None | code28 | KSRB 8.6.6. Providing and fixing on wall surface 2.5kg/Sq.cm HDPE rain down water pipe 90mm outer dia approved make and brand with necessary specials like shoues, bends, and offsets fixed with iron clamps, wall plugs, screws, including cost of materials labour curing compelte., as per speicifications,(PWD SR 2018-19, P.49,I.8.16. | Mtr | 365.0 | 365.0 | 27.0 | False | None | None | False | None | False | 9855.0 | 0 | 3682456 | 134952 | None | code29 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.(Volume-ii) (P.No.44, I.No.8.19.1) PWD SR 2023-24 | Sqm | 255.0 | 255.0 | 9.72 | False | None | None | False | None | False | 2478.6 | 0 | 3682457 | 134952 | None | code30 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(P.NO 17.I.NO 2.5.1 PWDCSR 2023-24 Volme I) for Chejja | Cum | 9613.5 | 9613.5 | 0.56 | False | None | None | False | None | False | 5383.56 | 0 | 3682458 | 134952 | None | code31 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(P.NO 17.I.NO 2.5.1 PWDCSR 2023-24 Volme I) for Slab | Cum | 9945.0 | 9945.0 | 4.59 | False | None | None | False | None | False | 45647.55 | 0 | 3682459 | 134952 | None | code32 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete (Volume-ii) (P.No.60, I.No.9.11) PWD SR 2023-24 | Cum | 1106.0 | 1106.0 | 65.58 | False | None | None | False | None | False | 72531.48 | 0 | 3682460 | 134952 | None | code33 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (P.NO.63.I.NO.9.23 PWD SR 2023-24 Volme II) | Unit | 3599.0 | 3599.0 | 1.0 | False | None | None | False | None | False | 3599.0 | 0 | 3682461 | 134952 | None | code34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(P.NO.123.I.NO.13.34 PWD SR 2023-24 Volme II) | Nos | 9.0 | 9.0 | 500.0 | False | None | None | False | None | False | 4500.0 | 0 | 3682462 | 134952 | None | code35 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 25 mm nominal dia Pipes (P.NO.122.I.NO.13.33.3 PWD SR 2023-24 Vol-II) | Mtr | 296.0 | 296.0 | 38.0 | False | None | None | False | None | False | 11248.0 | 0 | 3682463 | 134952 | None | code36 | Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm working pressure chemp plast / Wavin or equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials,with 110mm outer dia (P.No.77, I.No.11.56.2) PWD SR Shivamogga 2018-19 | Mtr | 606.0 | 606.0 | 8.0 | False | None | None | False | None | False | 4848.0 | 0 | 3682464 | 134952 | None | code37 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thick (P.NO. 1, I.NO.1.3.1) PWD Electrical SR 2023-24 | Mtr | 68.0 | 68.0 | 175.0 | False | None | None | False | None | False | 11900.0 | 0 | 3682465 | 134952 | None | code38 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3m from tapping point to out let via switch (P.NO. 2, I.NO.2.1.1) PWD Electrical SR 2023-24 | Point | 285.0 | 285.0 | 22.0 | False | None | None | False | None | False | 6270.0 | 0 | 3682466 | 134952 | None | code39 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3m from tapping point to out let via switch (P.NO. 2, I.NO.2.1.2) PWD Electrical SR 2023-24 | Point | 394.0 | 394.0 | 21.0 | False | None | None | False | None | False | 8274.0 | 0 | 3682467 | 134952 | None | code40 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3m from tapping point to out let via switch (P.NO. 2, I.NO.2.1.3) PWD Electrical SR 2023-24 | Point | 570.0 | 570.0 | 24.0 | False | None | None | False | None | False | 13680.0 | 0 | 3682468 | 134952 | None | code41 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8Way (P.NO. 5, I.NO.3.4.4) PWD Electrical SR 2023-24 | Each | 220.0 | 220.0 | 6.0 | False | None | None | False | None | False | 1320.0 | 0 | 3682469 | 134952 | None | code42 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way Switch (P.NO. 5, I.NO.3.6.1) PWD Electrical SR 2023-24 | Each | 102.0 | 102.0 | 6.0 | False | None | None | False | None | False | 612.0 | 0 | 3682470 | 134952 | None | code43 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps 3way socket (P.NO. 5, I.NO.3.6.3) PWD Electrical SR 2023-24 | Each | 171.0 | 171.0 | 6.0 | False | None | None | False | None | False | 1026.0 | 0 | 3682471 | 134952 | None | code44 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 1000-1200Watts Dimmer (P.NO. 5, I.NO.3.6.7 ) PWD Electrical SR 2023-24 | Each | 180.0 | 180.0 | 8.0 | False | None | None | False | None | False | 1440.0 | 0 | 3682472 | 134952 | None | code45 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch (P.NO. 5, I.NO.3.6.8) PWD Electrical SR 2023-24 | Each | 177.0 | 177.0 | 6.0 | False | None | None | False | None | False | 1062.0 | 0 | 3682473 | 134952 | None | code46 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32Amps DP switch (P.NO. 5, I.NO.3.6.10 ) PWD Electrical SR 2023-24 | Each | 236.0 | 236.0 | 6.0 | False | None | None | False | None | False | 1416.0 | 0 | 3682474 | 134952 | None | code47 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16Amps universal socke (P.NO. 5, I.NO.3.6.11 ) PWD Electrical SR 2023-24 | Each | 156.0 | 156.0 | 9.0 | False | None | None | False | None | False | 1404.0 | 0 | 3682475 | 134952 | None | code48 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall / ceiling / Rafter / Girders (P.NO. 45, I.NO.13.7.1 ) PWD Electrical SR 2023-24 | Each | 122.0 | 122.0 | 5.0 | False | None | None | False | None | False | 610.0 | 0 | 3682476 | 134952 | None | code49 | Supplying of .feet PVC Batten with integrated LED tube W with high quality diffuse with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fighting 1 x4'- 20/22 w (P.NO. 34, I.NO.11.3.2 ) PWD Electrical SR 2023-24 | Each | 690.0 | 690.0 | 4.0 | False | None | None | False | None | False | 2760.0 | 0 | 3682477 | 134952 | None | code50 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS 374/79 and also comply with IS 1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W 10, Rated current As per IS 374/79, Rated power factor 0.9 lagging (min), Rated speed 350 10 RPM, Rated air delivery 210 10 Cubic Meter Minimum, Rated service value 4.2 CMM Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor wdg temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt current, Air Delivery Fan Speed as per IS 374 1979 with latest amendment, 2 year manufacturer Warranty 48 Sweep 5 Star 1200mm (P.NO.23, .NO.6.4.1) PWD Electrical SR 2023-24 | Each | 2677.0 | 2677.0 | 7.0 | False | None | None | False | None | False | 18739.0 | 0 | 3682478 | 134952 | None | code51 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5 mm2 (P.NO. 3, I.NO.2.3.2) PWD Electrical SR 2023-24 | Mtr | 26.0 | 26.0 | 200.0 | False | None | None | False | None | False | 5200.0 | 0 | 3682479 | 134952 | None | code52 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2.5 mm2 (P.NO. 3, I.NO.2.3.3) PWD Electrical SR 2023-24 | Mtr | 42.0 | 42.0 | 280.0 | False | None | None | False | None | False | 11760.0 | 0 | 3682480 | 134952 | None | code53 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 4 mm2 (P.NO.3, I.NO.2.3.4) PWD Electrical SR 2023-24 | Mtr | 63.0 | 63.0 | 210.0 | False | None | None | False | None | False | 13230.0 | 0 | 3682481 | 134952 | None | code54 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.12 Way SP & N (P.NO.13, I.NO.5.19.4) PWD Electrical SR 2023-24 | Each | 1863.0 | 1863.0 | 7.0 | False | None | None | False | None | False | 13041.0 | 0 | 3682482 | 134952 | None | code55 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63 Amps DP (P.NO. 13, I.NO.5.18.6) PWD Electrical SR 2023-24 | Each | 1102.0 | 1102.0 | 10.0 | False | None | None | False | None | False | 11020.0 | 0 | 3682483 | 134952 | None | code56 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring (P.NO. 46, I.NO.13.10 ) PWD Electrical SR 2023-24 | Each | 171.0 | 171.0 | 7.0 | False | None | None | False | None | False | 1197.0 | 0 |
|