noticeInvitingTenderDTO
createdTs1722667474267
version12
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd24725.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-08-2024 17:30:00
tenderQueryClose09-08-2024 17:30:00
technicalBidOpenNone
publishedDate03-08-2024 12:22:26
publishedByPostCMC_MCOM_SHD
publishedByUserKPE14323 - K GURULINGAPPA
bidValidityPeriod90
noOfCalls4
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonSiddappa Sompur
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8073548798
tenderSupplierListNone
tenderSchedule
createdTs1722667474270
version30
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/OW/WORK_INDENT8301/CALL-4
titleConstruction of Public Toilet Near New CMC Shopping Complex in Shahabad Town.
descriptionConstruction of Public Toilet Near New CMC Shopping Complex in Shahabad Town.
categoryWORKS
categoryTextWorks
ecv988559.91
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2309
locationNameDMA City Municipal Council Shahabad
provisionalAmount1200000.0
groupOverheadTotalNone
fileNumberCMCSDB/SBM2/PT/1/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17226674740001NoneNoneOther WorksConstruction of Public Toilet Near New CMC Shopping Complex in Shahabad Town.988559.91
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3680079134795Nonecode01Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. In area of light jungleSqm412.65412.650.233FalseNoneNoneFalseNoneFalse96.147450
3680080134795Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 mCum107.1107.139.07FalseNoneNoneFalseNoneFalse4184.3970
3680081134795Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.23.6FalseNoneNoneFalseNoneFalse21409.920
3680082134795Nonecode04Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.95.03FalseNoneNoneFalseNoneFalse34952.9670
3680083134795Nonecode05Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.454.51FalseNoneNoneFalseNoneFalse30255.10950
3680084134795Nonecode06Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.351.46FalseNoneNoneFalseNoneFalse9637.9710
3680085134795Nonecode07Appendix I Additionalities for Formwork, Centering & Scaffolding Foundation upto Plinth b. All other typesCum198.04198.041.46FalseNoneNoneFalseNoneFalse289.13840
3680086134795Nonecode08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregatesCum6961.56961.51.7FalseNoneNoneFalseNoneFalse11834.550
3680087134795Nonecode09Appendix I Additionalities for Formwork, Centering & Scaffolding Columns & PiersCum4873.054873.051.7FalseNoneNoneFalseNoneFalse8284.1850
3680088134795Nonecode10Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregatesCum6961.56961.54.88FalseNoneNoneFalseNoneFalse33972.120
3680089134795Nonecode11Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of BuildingCum4176.94176.94.88FalseNoneNoneFalseNoneFalse20383.2720
3680090134795Nonecode12Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 design mix Using 20mm nominal size graded crushed coarse aggregatesCum6961.56961.54.78FalseNoneNoneFalseNoneFalse33275.970
3680091134795Nonecode13Appendix I Additionalities for Formwork, Centering & ScaffoldingRoof (Straight & Arched)Cum3480.753480.754.78FalseNoneNoneFalseNoneFalse16637.9850
3680092134795Nonecode14Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. BuildingsTonne93929.8593929.850.7FalseNoneNoneFalseNoneFalse65750.8950
3680093134795Nonecode15Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8621.558621.5519.67FalseNoneNoneFalseNoneFalse169585.88850
3680094134795Nonecode16Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum130412.1130412.10.224FalseNoneNoneFalseNoneFalse29212.31040
3680095134795Nonecode17Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm7816.27816.22.1FalseNoneNoneFalseNoneFalse16414.020
3680096134795Nonecode18Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.Mtr498.75498.7545.6FalseNoneNoneFalseNoneFalse22743.00
3680097134795Nonecode19Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges do- with one side prelamSqm2142.02142.012.6FalseNoneNoneFalseNoneFalse26989.20
3680098134795Nonecode20Providing and fixing in position Mathi/Nandi wood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures)Sqm7363.657363.653.24FalseNoneNoneFalseNoneFalse23858.2260
3680099134795Nonecode21Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg111.3111.3113.4FalseNoneNoneFalseNoneFalse12621.420
3680100134795Nonecode22Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm253.05253.0518.039FalseNoneNoneFalseNoneFalse4564.768950
3680101134795Nonecode23Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm389.55389.55230.865FalseNoneNoneFalseNoneFalse89933.460750
3680102134795Nonecode24Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.Sqm1622.251622.253.447FalseNoneNoneFalseNoneFalse5591.895750
3680103134795Nonecode25Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm933.45933.457.02FalseNoneNoneFalseNoneFalse6552.8190
3680104134795Nonecode26Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm143.85143.85115.881FalseNoneNoneFalseNoneFalse16669.481850
3680105134795Nonecode27Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm93.4593.4575.057FalseNoneNoneFalseNoneFalse7014.076650
3680106134795Nonecode28Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm144.9144.912.015FalseNoneNoneFalseNoneFalse1740.97350
3680107134795Nonecode29Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm145.95145.955.4FalseNoneNoneFalseNoneFalse788.130
3680108134795Nonecode30Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5128.25128.28.0FalseNoneNoneFalseNoneFalse41025.60
3680109134795Nonecode31Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixerEach3009.33009.32.0FalseNoneNoneFalseNoneFalse6018.60
3680110134795Nonecode32Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 1500x450 mmEach1812.31812.32.0FalseNoneNoneFalseNoneFalse3624.60
3680111134795Nonecode33Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 600X850 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etcEach6764.16764.14.0FalseNoneNoneFalseNoneFalse27056.40
3680112134795Nonecode34Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3Mtr431.55431.5520.0FalseNoneNoneFalseNoneFalse8631.00
3680113134795Nonecode35Providing and fixing unplasticised PVC connection pipe with brass unions :20 mm nominal boreNos115.5115.520.0FalseNoneNoneFalseNoneFalse2310.00
3680114134795Nonecode36Providing and fixing brss bib cock of approved quality etc.,Nos320.25320.2512.0FalseNoneNoneFalseNoneFalse3843.00
3680115134795Nonecode37Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal boreNos627.9627.96.0FalseNoneNoneFalseNoneFalse3767.40
3680116134795Nonecode38Providing and fixing brass stop cock of approved quality : 20 mm nominal boreNos320.25320.258.0FalseNoneNoneFalseNoneFalse2562.00
3680117134795Nonecode39Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.Ltr9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
3680118134795Nonecode40Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickMtr81.981.925.0FalseNoneNoneFalseNoneFalse2047.50
3680119134795Nonecode41Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thickMtr82.9582.9525.0FalseNoneNoneFalseNoneFalse2073.750
3680120134795Nonecode42Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction boxEach58.858.810.0FalseNoneNoneFalseNoneFalse588.00
3680121134795Nonecode43Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.10" x 7" x 3" (254 x 178 x 76 mm)Each117.6117.62.0FalseNoneNoneFalseNoneFalse235.20
3680122134795Nonecode44Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.8" x 6" x 3" (203 x 152 x 76 mm)Each90.390.32.0FalseNoneNoneFalseNoneFalse180.60
3680123134795Nonecode45Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.4" x 4" x 3" ( 101 x 101 x 76 mmEach77.777.72.0FalseNoneNoneFalseNoneFalse155.40
3680124134795Nonecode46Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. 12" x 9" x 3" (300 x 228 x 76 mm)Each120.75120.751.0FalseNoneNoneFalseNoneFalse120.750
3680125134795Nonecode47Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Short point upto 3m from tapping point to out let via switchPoint299.25299.252.0FalseNoneNoneFalseNoneFalse598.50
3680126134795Nonecode48Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Medium point above 3m upto 6m from tapping point to out let via switchPoint413.7413.72.0FalseNoneNoneFalseNoneFalse827.40
3680127134795Nonecode49Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Long point above 6m upto 10m from tapping point to out let via switchPoint598.5598.53.0FalseNoneNoneFalseNoneFalse1795.50
3680128134795Nonecode50Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 3C X 1.5 mm2Mtr75.675.625.0FalseNoneNoneFalseNoneFalse1890.00
3680129134795Nonecode51Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 4C x 1.5 mm2Mtr98.798.725.0FalseNoneNoneFalseNoneFalse2467.50
3680130134795Nonecode52Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 6C x 1.5 mm2Mtr127.05127.0525.0FalseNoneNoneFalseNoneFalse3176.250
3680131134795Nonecode53Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 8C x 1.5 mm2Mtr165.9165.925.0FalseNoneNoneFalseNoneFalse4147.50
3680132134795Nonecode54Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 3/5 WayEach154.35154.353.0FalseNoneNoneFalseNoneFalse463.050
3680133134795Nonecode55Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 2 WayEach134.4134.43.0FalseNoneNoneFalseNoneFalse403.20
3680134134795Nonecode56Supplying and mounting 2 Nos. of 2Way 6 A flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293Each186.9186.92.0FalseNoneNoneFalseNoneFalse373.80
3680135134795Nonecode57Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1-3 WayEach108.15108.152.0FalseNoneNoneFalseNoneFalse216.30
3680136134795Nonecode58Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 WayEach143.85143.852.0FalseNoneNoneFalseNoneFalse287.70
3680137134795Nonecode59Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular modelEach3133.23133.21.0FalseNoneNoneFalseNoneFalse3133.20
3680138134795Nonecode60Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & NEach5187.05187.01.0FalseNoneNoneFalseNoneFalse5187.00
3680139134795Nonecode61Supplying and fixing of retrofit type LED bulb .W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70 percentage. efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5 percentage of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 2%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18W, 6500KEach447.3447.310.0FalseNoneNoneFalseNoneFalse4473.00
3680140134795Nonecode62Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
3680141134795Nonecode63Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%,b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. Common SR WS&SW 2023-24 Vol-5 It. No. 12.4 Pg. No. 140Each5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3680142134795Nonecode64Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Common SR WS&SW 2023-24 Vol-5 It. No. 12.1,12.2 Pg. No. 139 0.00 to 50.00Mtr388.5388.550.0FalseNoneNoneFalseNoneFalse19425.00
3680143134795Nonecode65Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Common SR WS&SW 2023-24 Vol-5 It. No. 12.1,12.2 Pg. No. 139 50 to 100.00Mtr487.2487.210.0FalseNoneNoneFalseNoneFalse4872.00
3680144134795Nonecode66Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 160mm dia., 6 kg/sqcm & class 3 Common SR WS&SW 2023-24 Vol-5 It. No. 1.9 Pg. No. 134Mtr628.95628.9512.0FalseNoneNoneFalseNoneFalse7547.40
3680145134795Nonecode67PVC Filter casing Pipe -Market RateMtr328.63328.6312.0FalseNoneNoneFalseNoneFalse3943.560
3680146134795Nonecode68Providing borewell cap - Market RateMtr288.75288.751.0FalseNoneNoneFalseNoneFalse288.750
3680147134795Nonecode69Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments.1.50 HP/1.1KW 18 STG Common SR WS&SW 2023-24 Vol-5 It. No. 13.7.6 Pg. No. 150Each18423.318423.31.0FalseNoneNoneFalseNoneFalse18423.30
3680148134795Nonecode70Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type e NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter Upto 3 HP pumps Common SR WS&SW 2023-24 Vol-5 It. No. 13.23.1 Pg. No. 155Each6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3680149134795Nonecode71Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc.HDPE Grade PE80-PN16.0, 63mm dia Common SR WS&SW 2023-24 Vol-5 It. No. 9.5.1 Pg. No. 98Mtr343.35343.3555.0FalseNoneNoneFalseNoneFalse18884.250
3680150134795Nonecode72Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.1x3x4 Sqm Common SR WS&SW 2023-24 Vol-5 It. No. 13.22.3 Pg. No. 154Mtr141.75141.7555.0FalseNoneNoneFalseNoneFalse7796.250
3680151134795Nonecode73Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm Common SR WS&SW 2023-24 Vol-5 It. No. 13.24.1 Pg. No. 154Each1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3680152134795Nonecode74Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm Common SR WS&SW 2023-24 Vol-5 It. No. 133.25.1 Pg. No. 154Each1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3680153134795Nonecode75Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI mark Common SR WS&SW 2023-24 Vol-5 It. No. 13.30 Pg. No. 155Set4725.04725.01.0FalseNoneNoneFalseNoneFalse4725.00
3680154134795Nonecode76Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.Common SR WS&SW 2023-24 Vol-5 It. No. 13.32 Pg. No. 156Job6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3680155134795Nonecode77Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.Common SR WS&SW 2023-24 Vol-5 It. No. 13.33 Pg. No. 156Job1417.51417.51.0FalseNoneNoneFalseNoneFalse1417.50
3680156134795Nonecode78Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit.Common SR WS&SW 2023-24 Vol-5 It. No. 13.36 Pg. No. 156Mtr141.75141.756.0FalseNoneNoneFalseNoneFalse850.50
3680157134795Nonecode79Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.Common SR WS&SW 2023-24 Vol-5 It. No. 13.31 Pg. No. 155Job42.042.055.0FalseNoneNoneFalseNoneFalse2310.00
3680158134795Nonecode80Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Common SR WS&SW 2023-24 Vol-5 It. No. 13.39 Pg. No. 157Job3937.53937.51.0FalseNoneNoneFalseNoneFalse3937.50
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17226674740000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17226674740000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17226674740000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17226674740000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17226674740000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17226674740000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17226674740000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17226674740000NoneNoneELIGIBILITYBanker DetailsNone
17226674740000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reasons or what so everNone
17226674740000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejectNone
17226674740000NoneNoneELIGIBILITYGST will be paid separatelyNone
17226674740000NoneNoneELIGIBILITYToilet operation and maintenance to be taken care by toilet constructing contractor upto 5 yearsNone
17226674740000NoneNoneELIGIBILITYAll terms and conditions are as per tender documentsNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Registration Certificate issued By PWD DepartmentTrueTechnical Bid
Last five years Annual Turnover CertificateTrueTechnical Bid
Similar Nature of work done for both physical and financialTrueTechnical Bid
PF and ESI Registration with last 3 months challanTrueTechnical Bid
Last three years Income tax return certificateTrueTechnical Bid
GST registration certificate and Pan Card DetailsTrueTechnical Bid
Unconditional Banker CertificateTrueTechnical Bid
All terms and conditions are as per tender documentsTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone