createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1722517725100
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd30000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-08-2024 16:30:00
tenderQueryClose08-08-2024 11:00:00
technicalBidOpenNone
publishedDate02-08-2024 18:34:15
publishedByPostTMC_CO_TRD
publishedByUserKPE16653 - ANAND KESARAGOPPA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonAnand kesargoppa
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8050941807
tenderSupplierListNone
tenderSchedule
createdTs1722517725137
version6
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/WS/WORK_INDENT23435
titleDrilling of bore well and installation of submersible pump sets, laying of pipeline, construction cistern tank at ward no 5 6 8 in the limit of TMC Terdal
descriptionDrilling of bore well and installation of submersible pump sets, laying of pipeline, construction cistern tank at ward no 5 6 8 in the limit of TMC Terdal
categoryWORKS
categoryTextWorks
ecv1200000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2221
locationNameDMA Town Municipal Council Terdal
provisionalAmount1200000.0
groupOverheadTotal186882.7
fileNumberDMA/2024-25/TMC/TDL/15FC/9
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17225177250000NoneNoneWater supply/sewage linesDrilling of bore well and installation of submersible pump sets, laying of pipeline, construction cistern tank at ward n 6336849.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3670305134043None001Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test.( PWD SR 2023-24 Vol-5 , P.No -140, I No - 12.4 ) Each5446.645446.641.0FalseNoneNoneFalseNoneFalse5446.640
3670306134043None002Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) .Borewell depth of 0 to 50 Mtrs( PWD SR 2023-24 Vol-5 , P.No -139, I No - 12.2.1 ) Mtr318.27318.2750.0FalseNoneNoneFalseNoneFalse15913.50
3670307134043None003do above item no 2 specifiction but Borewell depth of 50 to 100 m ( PWD SR 2023-24 Vol-5 , P.No -139, I No - 12.2.2) Mtr398.61398.6150.0FalseNoneNoneFalseNoneFalse19930.50
3670308134043None004do above item no 2 specifiction but Borewell depth of 50 to 100 m ( PWD SR 2023-24 Vol-5 , P.No -139, I No - 12.2.2) Mtr424.36424.3650.0FalseNoneNoneFalseNoneFalse21218.00
3670309134043None005do above item no 2 specifiction but Borewell depth of 150 to 160 m ( PWD SR 2023-24 Vol-5 , P.No -139, I No - 12.2.4) Mtr492.34492.3450.0FalseNoneNoneFalseNoneFalse24617.00
3670310134043None006do above item no 2 specifiction but Borewell depth of 200 to 240 m ( PWD SR 2023-24 Vol-5 , P.No -139, I No - 12.2.5) Mtr576.8576.840.0FalseNoneNoneFalseNoneFalse23072.00
3670311134043None007Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing etc PVC pipes 200mm dia 6kg/sqcm & class 3 used as a casing pipe ( PWD SR 2023-24 Vol- 5, P.No -113 , I No - 10.1.10 ) Mtr1148.451148.4520.0FalseNoneNoneFalseNoneFalse22969.00
3670312134043None008Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge( PWD SR 2023-24 Vol- 5 , P.No -143,I No - 12.34) Nos168.92168.921.0FalseNoneNoneFalseNoneFalse168.920
3670313134043None009Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments 1x3x4 Sqm .(PWD SR 2023-24 Vol- 5 , P.No -154, I No - 13.22.3 ) Mtr139.05139.05260.0FalseNoneNoneFalseNoneFalse36153.00
3670314134043None010Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.(PWD SR 2023-24 Vol- 5 , P.No -155, I No - 13.31 ) Mtr41.241.2260.0FalseNoneNoneFalseNoneFalse10712.00
3670315134043None011Providing Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete. For 3 HP etc. complete. 3.00 HP/2.2KW 30 STG ( PWD SR 2023-24 Vol- 5 , P.No -151,I No. 13.4 & .13-9.6) Set25265.925265.92.0FalseNoneNoneFalseNoneFalse50531.80
3670316134043None012Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.( PWD SR 2023-24 Vol- 5 , P.No -156, I No - 13.32 ) Nos6695.06695.01.0FalseNoneNoneFalseNoneFalse6695.00
3670317134043None013KSRB13-9 : Providing and fixing to wall, ceiling and floor high density polyethylene pipes 6.00 kgf/sq.cm working pressure of outside diameter raising mains & exposed distribution pipes with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM and testing complete as per Specification No. KBS 13.2.15.2/13.9 HDPE Pipe 40mm Dai (SR 2018-19 BGV P.No 96 I.No 13.72) Mtr275.1275.1300.0FalseNoneNoneFalseNoneFalse82530.00
3670318134043None014Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. 3.5 x 6 sqmm. ( PWD SR 2023-24 Vol- 5 , P.No -156, I No - 13.35. 2) Mtr164.8164.830.0FalseNoneNoneFalseNoneFalse4944.00
3670319134043None015Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. ( PWD SR 2023-24 Vol- 5 , P.No -157, I No - 13.39) Job3862.53862.51.0FalseNoneNoneFalseNoneFalse3862.50
3670320134043None016Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete Upto 3 HP pumps ( PWD SR 2023-24 Vol- 5 , P.No -154, I No - 13.23.1) Job6695.06695.01.0FalseNoneNoneFalseNoneFalse6695.00
3670321134043None017Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.( PWD SR 2023-24 Vol- 5 , P.No -156, I No - 13.33) Job1390.51390.51.0FalseNoneNoneFalseNoneFalse1390.50
17225177250000NoneNoneWater supply/sewage linesDrilling of bore well and installation of submersible pump sets, laying of pipeline, construction cistern tank at ward no 8337725.58
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3670322134044None001Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test.( PWD SR 2023-24 Vol-5 , P.No -140, I No - 12.4 ) Each5446.645446.641.0FalseNoneNoneFalseNoneFalse5446.640
3670323134044None002Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) .Borewell depth of 0 to 50 Mtrs( PWD SR 2023-24 Vol-5 , P.No -139, I No - 12.2.1 ) Mtr318.27318.2750.0FalseNoneNoneFalseNoneFalse15913.50
3670324134044None003do above item no 2 specifiction but Borewell depth of 50 to 100 m ( PWD SR 2023-24 Vol-5 , P.No -139, I No - 12.2.2) Mtr398.61398.6150.0FalseNoneNoneFalseNoneFalse19930.50
3670325134044None004do above item no 2 specifiction but Borewell depth of 100 to 150 m ( PWD SR 2023-24 Vol-5 , P.No -139, I No - 12.2.3) Mtr424.36424.3650.0FalseNoneNoneFalseNoneFalse21218.00
3670326134044None005do above item no 2 specifiction but Borewell depth of 150 to 160 m ( PWD SR 2023-24 Vol-5 , P.No -139, I No - 12.2.4) Mtr492.34492.3450.0FalseNoneNoneFalseNoneFalse24617.00
3670327134044None006do above item no 2 specifiction but Borewell depth of 200 to 240 m ( PWD SR 2023-24 Vol-5 , P.No -139, I No - 12.2.5) Mtr576.8576.830.0FalseNoneNoneFalseNoneFalse17304.00
3670328134044None007Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing etc PVC pipes 200mm dia 6kg/sqcm & class 3 used as a casing pipe ( PWD SR 2023-24 Vol- 5, P.No -113 , I No - 10.1.10 ) Mtr1148.451148.4515.0FalseNoneNoneFalseNoneFalse17226.750
3670329134044None008Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge( PWD SR 2023-24 Vol- 5 , P.No -143,I No - 12.34) Nos168.92168.921.0FalseNoneNoneFalseNoneFalse168.920
3670330134044None009Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments 1x3x4 Sqm .(PWD SR 2023-24 Vol- 5 , P.No -154, I No - 13.22.3 ) Mtr139.05139.05250.0FalseNoneNoneFalseNoneFalse34762.50
3670331134044None010Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.(PWD SR 2023-24 Vol- 5 , P.No -155, I No - 13.31 ) Mtr41.241.2250.0FalseNoneNoneFalseNoneFalse10300.00
3670332134044None011Providing Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete. For 3 HP etc. complete. 3.00 HP/2.2KW 30 STG ( PWD SR 2023-24 Vol- 5 , P.No -151,I No. 13.4 & .13-9.6) Set25265.925265.91.0FalseNoneNoneFalseNoneFalse25265.90
3670333134044None012Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.( PWD SR 2023-24 Vol- 5 , P.No -156, I No - 13.32 ) Nos6695.06695.01.0FalseNoneNoneFalseNoneFalse6695.00
3670334134044None013KSRB13-9 : Providing and fixing to wall, ceiling and floor high density polyethylene pipes 6.00 kgf/sq.cm working pressure of outside diameter raising mains & exposed distribution pipes with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM and testing complete as per Specification No. KBS 13.2.15.2/13.9 HDPE Pipe 40mm Dai (SR 2018-19 BGV P.No 96 I.No 13.72) Mtr275.1275.1260.0FalseNoneNoneFalseNoneFalse71526.00
3670335134044None014Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. 3.5 x 6 sqmm. ( PWD SR 2023-24 Vol- 5 , P.No -156, I No - 13.35. 2) Mtr164.8164.825.0FalseNoneNoneFalseNoneFalse4120.00
3670336134044None015Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. ( PWD SR 2023-24 Vol- 5 , P.No -157, I No - 13.39) Nos3862.53862.51.0FalseNoneNoneFalseNoneFalse3862.50
3670337134044None016Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete Upto 3 HP pumps ( PWD SR 2023-24 Vol- 5 , P.No -154, I No - 13.23.1) Job6695.06695.01.0FalseNoneNoneFalseNoneFalse6695.00
3670338134044None017Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.( PWD SR 2023-24 Vol- 5 , P.No -156, I No - 13.33) Job1390.51390.51.0FalseNoneNoneFalseNoneFalse1390.50
3670339134044None018Earth work excavation by manual means for drains, canals, waste weir, draft approach channels, key trenches, foundation of Buildings & bridges and suchsimillar works in all kinds of soils, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sidesneatly dressed disposing off the excavated stuff or sorting & stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost oflabour, tools & other appurtenaces required to complete the work. P No 5,I.No-1.4 vol-1 PWD23-24 Cum249.26249.261.35FalseNoneNoneFalseNoneFalse336.5010
3670340134044None019Providing and laying in position Cement Concrete for levelling course forall works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates P. No 15,I No 2.1.2 vol 1 PWD 23-24 Cum5833.925833.920.34FalseNoneNoneFalseNoneFalse1983.53280
3670341134044None020Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand ) P No 9 I No 5.2 Vol 2 PWD 23-24 Cum6816.546816.543.0375FalseNoneNoneFalseNoneFalse20705.240250
3670342134044None021Providing and laying in position Cement Concrete for levelling course forall works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates P No 2.1.4 I No 2.1.4 PWD 23-24 Cum6403.516403.510.68FalseNoneNoneFalseNoneFalse4354.38680
3670343134044None022Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) tobrick/stone masonry including rounding off corners wherever requiredsmooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge P No 41, I No 8.3.1 vol 2 PWD 23-24 Sqm364.62364.626.0FalseNoneNoneFalseNoneFalse2187.720
3670344134044None023RCC hume pipe Circular pump house: Providing precast RCC CircularHume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm etc. complete.P No 116 I No 10.6 vol 5 PWD 23-24 Nos16893.0316893.031.0FalseNoneNoneFalseNoneFalse16893.030
3670345134044None024Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work P No 116 I No 10.7 Vol 5 Nos1938.461938.461.0FalseNoneNoneFalseNoneFalse1938.460
3670346134044None025Providing and fixing GI 50mm dia chavi set consisting of 3nos 20mm bib cocks complete as per sample kept in the office premises including cost of transportation labour charges etc as per instruction of engineering in charges MR Nos2884.02884.01.0FalseNoneNoneFalseNoneFalse2884.00
17225177250000NoneNoneWater supply/sewage linesDrilling of bore well and installation of submersible pump sets, laying of pipeline, construction cistern tank at ward no 5 in the limit of TMC Terdal338542.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3670347134045None001Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test.( PWD SR 2023-24 Vol-5 , P.No -140, I No - 12.4 ) Each5446.645446.641.0FalseNoneNoneFalseNoneFalse5446.640
3670348134045None002Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) .Borewell depth of 0 to 50 Mtrs( PWD SR 2023-24 Vol-5 , P.No -139, I No - 12.2.1 ) Mtr318.27318.2750.0FalseNoneNoneFalseNoneFalse15913.50
3670349134045None003do above item no 2 specifiction but Borewell depth of 50 to 100 m ( PWD SR 2023-24 Vol-5 , P.No -139, I No - 12.2.2) Mtr398.61398.6150.0FalseNoneNoneFalseNoneFalse19930.50
3670350134045None004do above item no 2 specifiction but Borewell depth of 100 to 150 m ( PWD SR 2023-24 Vol-5 , P.No -139, I No - 12.2.3) Mtr424.36424.3650.0FalseNoneNoneFalseNoneFalse21218.00
3670351134045None005do above item no 2 specifiction but Borewell depth of 150 to 160 m ( PWD SR 2023-24 Vol-5 , P.No -139, I No - 12.2.4) Mtr492.34492.3450.0FalseNoneNoneFalseNoneFalse24617.00
3670352134045None006do above item no 2 specifiction but Borewell depth of 200 to 240 m ( PWD SR 2023-24 Vol-5 , P.No -139, I No - 12.2.5) Mtr576.8576.840.0FalseNoneNoneFalseNoneFalse23072.00
3670353134045None007Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing etc PVC pipes 200mm dia 6kg/sqcm & class 3 used as a casing pipe ( PWD SR 2023-24 Vol- 5, P.No -113 , I No - 10.1.10 ) Mtr1148.451148.4520.0FalseNoneNoneFalseNoneFalse22969.00
3670354134045None008Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments.( PWD SR 2023-24 Vol- 5 , P.No -143,I No - 12.33) Nos154.5154.55.0FalseNoneNoneFalseNoneFalse772.50
3670355134045None009Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge( PWD SR 2023-24 Vol- 5 , P.No -143,I No - 12.34) Nos168.92168.921.0FalseNoneNoneFalseNoneFalse168.920
3670356134045None010Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments 1x3x4 Sqm .(PWD SR 2023-24 Vol- 5 , P.No -154, I No - 13.22.3 ) Mtr139.05139.05260.0FalseNoneNoneFalseNoneFalse36153.00
3670357134045None011Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets.(PWD SR 2023-24 Vol- 5 , P.No -155, I No - 13.31 ) Mtr41.241.2240.0FalseNoneNoneFalseNoneFalse9888.00
3670358134045None012Providing Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete. For 3 HP etc. complete. 3.00 HP/2.2KW 30 STG ( PWD SR 2023-24 Vol- 5 , P.No -151,I No. 13.4 & .13-9.6) Nos25265.925265.92.0FalseNoneNoneFalseNoneFalse50531.80
3670359134045None013Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.( PWD SR 2023-24 Vol- 5 , P.No -156, I No - 13.32 ) Nos6695.06695.02.0FalseNoneNoneFalseNoneFalse13390.00
3670360134045None014KSRB13-9 : Providing and fixing to wall, ceiling and floor high density polyethylene pipes 6.00 kgf/sq.cm working pressure of outside diameter raising mains & exposed distribution pipes with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM and testing complete as per Specification No. KBS 13.2.15.2/13.9 HDPE Pipe 40mm Dai (SR 2018-19 BGV P.No 96 I.No 13.72) Mtr275.1275.1285.0FalseNoneNoneFalseNoneFalse78403.50
3670361134045None015Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. 3.5 x 6 sqmm. ( PWD SR 2023-24 Vol- 5 , P.No -156, I No - 13.35. 2) Mtr164.8164.825.0FalseNoneNoneFalseNoneFalse4120.00
3670362134045None016Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. ( PWD SR 2023-24 Vol- 5 , P.No -157, I No - 13.39) Job3862.53862.51.0FalseNoneNoneFalseNoneFalse3862.50
3670363134045None017Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete Upto 3 HP pumps ( PWD SR 2023-24 Vol- 5 , P.No -154, I No - 13.23.1) Job6695.06695.01.0FalseNoneNoneFalseNoneFalse6695.00
3670364134045None018Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work.( PWD SR 2023-24 Vol- 5 , P.No -156, I No - 13.33) Job1390.51390.51.0FalseNoneNoneFalseNoneFalse1390.50
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17225177290000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17225177290000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17225177290000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17225177290000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17225177290000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17225177290001NoneNoneELIGIBILITYBidder/Contractor must attach Valid Civil PWD registration licence CertificateNone
17225177290001NoneNoneELIGIBILITYBidder/Contractor to qualify for award of this contract must attach Turnover Certificate certified by CA of last five years i.e.,2018-19, 2019-20 ,2020-21, 2021-22 and 2022-23 achieved in at least two financial years a minimum financial turnover of usually not less than two times the estimate cost.None
17225177290001NoneNoneELIGIBILITYBidder/Contractor to qualify for award of this contract must attach similar nature of work done certificate indicating the Indent number and bill amount, and which should be certified from the competent authority not less than rank of Executive Engineer, satisfactorily completed at least 50 percentage of the contract value, as prime contractor, i.e.,2018-19, 2019-20 ,2020-21, 2021-22 and 2022-23None
17225177290001NoneNoneELIGIBILITYBidder/Contractor must attach clear scan copy of Nationalized/Scheduled bank DD for difference amount if rates quoted below SR in the name of Chief Officer TMC TerdalNone
17225177290000NoneNoneELIGIBILITYBanker DetailsNone
17225179370000NoneNoneELIGIBILITYBidder/Contractor must attach all other required documents as per KW-1None
17225179530000NoneNoneELIGIBILITYBidder/Contractor must read carefully all the qualification criteria and bid documents and attach all the needful documents without fail.None
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Bidder/Contractor must attach Valid Civil PWD registration licence CertificateTrueTechnical Bid
Bidder/Contractor to qualify for award of this contract must attach Turnover Certificate certified by CA of last five years i.e, 2019-20 ,2020-21, 2021-22, 2022-23, and 2023-24 achieved in at least two financial years a minimum financial turnover of usually not less than two times the estimate cost.TrueTechnical Bid
Bidder/Contractor to qualify for award of this contract must attach similar nature of work done certificate indicating the Indent number and bill amount, and which should be certified from the competent authority not less than rank of Executive Engineer, satisfactorily completed at least 50 percentage of the contract value, as prime contractor, i.e., 2019-20 ,2020-21, 2021-22, 2022-23, and 2023-24TrueTechnical Bid
Bidder/Contractor must attach clear scan copy of Nationalized/Scheduled bank DD for difference amount if rates quoted below SR in the name of Chief Officer TMC TerdalTrueTechnical Bid
Bidder/Contractor must attach all other required documents as per KW-1TrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone