noticeInvitingTenderDTO
createdTs1722521788574
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd28750.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-08-2024 16:30:00
tenderQueryClose08-08-2024 11:00:00
technicalBidOpenNone
publishedDate02-08-2024 18:21:37
publishedByPostTMC_CO_TRD
publishedByUserKPE16653 - ANAND KESARAGOPPA
bidValidityPeriod90
noOfCalls2
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonAnand kesargoppa
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8050941807
tenderSupplierListNone
tenderSchedule
createdTs1722521788577
version12
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/WS/WORK_INDENT13176/CALL-2
titleDrilling of borewells and construction of cistern tanks providing of pump sets and laying of pipe line in the limit of TMC Terdal
descriptionDrilling of borewells and construction of cistern tanks, providing of pump sets and laying of pipe line in the limit of TMC Terdal
categoryWORKS
categoryTextWorks
ecv1150000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2221
locationNameDMA Town Municipal Council Terdal
provisionalAmount1150000.0
groupOverheadTotal178967.02
fileNumberDMA/2023-24/TDL/WS/M15/1
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17225217890000NoneNoneWater supply/sewage linesDrilling of Borewell and fixing of submersible pump set at ward no 16 near old police station312307.99
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3670849134086None001Geophysical investigation at site for sinking borewells for Providing, drinking water to the habitation either through the Hand Pump MWS, or P.W.S.S, by vertical electrical sounding by adopting Venner or, Schlum bergers's method, including reconnaissance survey of geological, formation. Geophysical, investigation of existing ground water in the, vicinity, its quality, quantity and acceptability of the users, indicating, the location of the site, recommended depth of casing pipe required to, seal the top unconsolidated formation including an extra depth of 1.0, metre in consolidated formation for proper seating of casing pipe, depth, of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation, of instruments and accessories to work site, engaging technical personal, and labour required etc. NOTE: 1) Additional rate on item 1&2 is, allowed for drilling in over burden and fixing Casing pipes beyond 20, M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the, depth of casing pipe fixed excluding initial depth of 20M and projection,above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry, Borewell towards yield test. etc. complete Page no.140, Item no.12.4 PWD WS&UGD SR 2023-24 Volume VNos5446.645446.641.0FalseNoneNoneFalseNoneFalse5446.640
3670850134086None002Sinking of Borewell of 165mm dia clear using super fast hydraulic rig, of capacity 300 PSIG & above 1100 CMF & above in all strata including, over burdern upto 20 m. Fixing of casing pipes, collars and cap with, necessary cutting, threading and welding including transportation of, rig and supporting vehicle, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimum, working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every,50m depth) 0 To 50 m Page no.139, Item no.12.1.1 PWD WS&UGD SR 2023-24 Volume VMtr381.1381.150.0FalseNoneNoneFalseNoneFalse19055.00
3670851134086None003Do Above item no 02 specification but borewell depth 50 To 100 m Page no.139, Item no.12.1.1 PWD WS&UGD SR 2023-24 Volume VMtr477.92477.9250.0FalseNoneNoneFalseNoneFalse23896.00
3670852134086None004Do Above item no 03 specification but borewell depth 100 To 150 m Page no.139, Item no.12.1.1 PWD WS&UGD SR 2023-24 Volume VMtr507.79507.7950.0FalseNoneNoneFalseNoneFalse25389.50
3670853134086None005Do Above item no 04 specification but borewell depth 150 To 200 m Page no.139, Item no.12.1.1 PWD WS&UGD SR 2023-24 Volume VMtr589.16589.1650.0FalseNoneNoneFalseNoneFalse29458.00
3670854134086None006Do Above item no 04 specification but borewell depth 200 To 210 m Page no.139, Item no.12.1.1 PWD WS&UGD SR 2023-24 Volume VMtr691.13691.1310.0FalseNoneNoneFalseNoneFalse6911.30
3670855134086None007Supply of ISI mark 175mm nominal bore,plain and steel casing pipe, grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and,latest ammendments, electrical resistance welded steel tubes, material,and conforming to IS 1387-1993 and manufactured by basic open, hearth electric or basic oxygen process in random length of 5-7m both, ends.threaded conforming to IS 554-1985 one end fixed with socket, conforming to IS 4270-2001 and the other end with screwed pipes all, shall be responsibaly free from defects. The tubes shall be responsible, straight end should be with ISI marking weighing 25.10kg/m.prices, include Collar-Medium duty. Page no.143, Item no.12.32 PWD WS&UGD SR 2023-24 Volume VMtr1990.991990.997.0FalseNoneNoneFalseNoneFalse13936.930
3670856134086None008Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with, all latest amendments if any for any dia. The thickness of plate used for, covering one end shall be 3mm (minimum). The dimensions of caps and, colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments Page no.143, Item no.12.33 PWD WS&UGD SR 2023-24 Volume VMtr154.5154.51.0FalseNoneNoneFalseNoneFalse154.50
3670857134086None009Providing and laying at site of work MS casing caps as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness, of plate used for covering one end shall be 3mm (minimum). Thedimensions of caps and colars shall be strictly as per IS 1239 (Part-II)1982 with all amendments including cost of material and labour chargesfor fixing, if any etc. complete with all lead and lifts and as directed bythe Engineer in charge Page no.143, Item no.12.34 PWD WS&UGD SR 2023-24 Volume VNo168.92168.921.0FalseNoneNoneFalseNoneFalse168.920
3670858134086None010Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.1x3x6 Sqm Page no 151, I No13.22.4 Vol 5 SR 2023-24Mtr190.55190.55180.0FalseNoneNoneFalseNoneFalse34299.00
3670859134086None011HDPE Pipe 32 mm Dia (SR 2018-19-BGV-P.No 95 I.No-13.72)Mtr284.43284.43540.0FalseNoneNoneFalseNoneFalse153592.20
17225217890000NoneNoneWater supply/sewage linesRe drilling of borewell and laying of PVC pipeline and Construction of Cistern tank near mallikarjun temple and appu mangasuli shop in the limit of tmc terdal254032.59
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3670860134087None001Cleaning of borewells including yield testing of borewell either using slow or fast rigs for not more than 2 hours at the final depth with a minimum working of 2 hours continuously with air compressor or suitable pump as per specification, including the cost of transportation charges, crew charges, cost of consumables etc. complete P. No 140 I No 12.5 vol 5 PWD 23-24No19530.8619530.861.0FalseNoneNoneFalseNoneFalse19530.860
3670861134087None002Positioning of the rig for retrival of failed borewells, raising mast and aligning the hammer and drill rods moounded on the rotary head of the rig concentric with borewell of 140-149 mm dia. to be retrived (wherever further geo-physical investigation has revealed that the existing aquifer /aquifers have not been tapped to the full depth) including selection of the suitable bit for deepening etc. The cost is for the work of Each bore well. P. No 140 I No 12.3 vol 5 PWD 23-24No3302.183302.181.0FalseNoneNoneFalseNoneFalse3302.180
3670862134087None003Re-drilling of filled-up borewell, including yield test at final depth. P No 140 I No 12.6 Vol 5 PWD 23-24Mtr457.32457.32130.0FalseNoneNoneFalseNoneFalse59451.60
3670863134087None004Earth work excavation by manual means for drains, canals, waste weir, draft approach channels, key trenches, foundation of Buildings & bridges and suchsimillar works in all kinds of soils, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sidesneatly dressed disposing off the excavated stuff or sorting & stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost oflabour, tools & other appurtenaces required to complete the work. P No 5,I.No-1.4 vol-1 PWD23-24Cum249.26249.261.8FalseNoneNoneFalseNoneFalse448.6680
3670864134087None005Providing and laying in position Cement Concrete for levelling course forall works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates P. No 15,I No 2.1.2 vol 1 PWD 23-24Cum5833.925833.920.34FalseNoneNoneFalseNoneFalse1983.53280
3670865134087None006Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand ) P No 9 I No 5.2 Vol 2 PWD 23-24Cum6816.546816.542.03FalseNoneNoneFalseNoneFalse13837.57620
3670866134087None007Providing and laying in position Cement Concrete for levelling course forall works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates P No 2.1.4 I No 2.1.4 PWD 23-24Cum6403.516403.510.34FalseNoneNoneFalseNoneFalse2177.19340
3670867134087None008Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) tobrick/stone masonry including rounding off corners wherever requiredsmooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge P No 41, I No 8.3.1 vol 2 PWD 23-24Sqm364.42364.423.6FalseNoneNoneFalseNoneFalse1311.9120
3670868134087None009RCC hume pipe Circular pump house: Providing precast RCC CircularHume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm etc. complete.P No 116 I No 10.6 vol 5 PWD 23-24No16893.0316893.031.0FalseNoneNoneFalseNoneFalse16893.030
3670869134087None010Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work P No 116 I No 10.7 Vol 5No1938.461938.461.0FalseNoneNoneFalseNoneFalse1938.460
3670870134087None011Providing and fixing GI 50mm dia chavi set consisting of 3nos 20mm bib cocks complete as per sample kept in the office premises including cost of transportation labour charges etc as per instruction of engineering in charges MRNo2884.02884.01.0FalseNoneNoneFalseNoneFalse2884.00
3670871134087None012Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments P No 155 I No 13.28 Vol 5Mtr566.5566.5170.0FalseNoneNoneFalseNoneFalse96305.00
3670872134087None013Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m PWD SR 2023-24 Volume 1 Page.No.8, It.No 1.6.1Cum498.52498.5228.8FalseNoneNoneFalseNoneFalse14357.3760
3670873134087None014Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: SR 2023 -24 P No 113 I No 10.1.4 Vol 5Mtr165.83165.8380.0FalseNoneNoneFalseNoneFalse13266.40
3670874134087None015Supplying of special moulded variety PVC couplers as per IS 7834/1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete. SR 2023-24 Vol-5 It. No.10.8.5 Pg. No.116No44.2944.294.0FalseNoneNoneFalseNoneFalse177.160
3670875134087None016Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 90 mm dia PVC Elbows SR 2023-24 Vol-5 It. No.10.9.5 Pg. No.117No104.03104.034.0FalseNoneNoneFalseNoneFalse416.120
3670876134087None017Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 90 mm dia PVC BEND SR 2023-24 Vol-5 It. No.10.11.5 Pg. No.118No172.01172.014.0FalseNoneNoneFalseNoneFalse688.040
3670877134087None018Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 63 mm dia PVC Tee SR 2023-24 Vol-5 It. No.10.10.5 Pg. No.117No79.3179.314.0FalseNoneNoneFalseNoneFalse317.240
3670878134087None019Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications SR 2023-24 Vol-1 It. No.1.10 Pg. No.7Cum164.8164.828.8FalseNoneNoneFalseNoneFalse4746.240
17225217890000NoneNoneWater supply/sewage linesProviding rising main line air valve at jack well at limit of TMC Terdal404692.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3670879134088None001Providing and fixing of Single/ Double chamber triple function tamper proof (Both the orifces to be housed in the single chamber) Air valves with Body and cover in Ductile cast iron of grade GGG 40/ 50. All internal parts such as float, shell with appurtenances., all cover bolts of austenitic alloy / SS 304 steel, DN 50 float of HOSTAFLON / SS 304 and gaskers and seals of EPDM. Epoxy powder coating (EP-P) inside and outside colour blue RAL5005. The valves should be designed for all the three functions i.e., 1. Large orifice for venting of large air volumes on start up. 2. Large orifice for intake of large air volumes. 3. Small orifice for discharge of pressurized air during operation.For PN 10.0 etc. complete For TP Air Valves of 100mm dia.Each38191.3738191.377.0FalseNoneNoneFalseNoneFalse267339.590
3670880134088None002Providing and fixing of ductile iron double flanged swing check valves with slanted seat or with lever weight with straight disc, with metallic corrosion proof and wear resistant seat faces with nickel overlay micro - finished/ Integral seat with body and disc in Ductile Iron in GGG 40/50 shaft of stainless steel and bearings of zinc free bronze and surface protection with epoxy liquid of GSK quality etc complete For PN 10.0 100mm diaEach17624.3317624.337.0FalseNoneNoneFalseNoneFalse123370.310
3670881134088None003Providing 50mm dia heavy class 100 mm dia CI flange and socket tail pieces confirming IS 1538 [Part-I to xxii] 1978 with latest amendments if any cast of all, materials, labor charges etcNo997.5997.57.0FalseNoneNoneFalseNoneFalse6982.50
3670882134088None004Cutting and rewinding of M.S Pipes for fixing of valves by engaging welding machine, labors etcNo1000.01000.07.0FalseNoneNoneFalseNoneFalse7000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17225217890000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17225217890000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17225217890000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17225217890000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17225217890000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17225217890000NoneNoneELIGIBILITYList of existing commitments and ongoing workNone
17225217890000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17225217890000NoneNoneELIGIBILITYBanker DetailsNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Bidder/Contractor must attach Valid Civil registration licence CertificateTrueTechnical Bid
Bidder/Contractor to qualify for award of this contract must attach Turnover Certificate certified by CA of last five years i.e, 2019-20 ,2020-21, 2021-22, 2022-23, and 2023-24 achieved in at least two financial years a minimum financial turnover of usually not less than two times the estimate cost.TrueTechnical Bid
Bidder/Contractor to qualify for award of this contract must attach similar nature of work done certificate indicating the Indent number and bill amount, and which should be certified from the competent authority not less than rank of Executive Engineer, satisfactorily completed at least 50 percentage of the contract value, as prime contractor, i.e., 2019-20 ,2020-21, 2021-22, 2022-23, and 2023-24TrueTechnical Bid
Bidder/Contractor must attach clear scan copy of Nationalized/Scheduled bank DD for difference amount if rates quoted below SR in the name of Chief Officer TMC Terdal.TrueTechnical Bid
Bidder/Contractor must attach all other required documents as per KW-1TrueTechnical Bid
Bidder/Contractor must read carefully all the qualification criteria and bid documents and attach all the needful documents without fail.TrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone